Proposed Academic Building For Department Of Instrumentation And Usic Ground Floor Under Rusa 2 Proposed Academic Building For Department Of Instrumentation And Usic Ground Floor At Gauhati University Under Rusa 2
Tender Overview
Project Description
Proposed Academic Building For Department Of Instrumentation And Usic Ground Floor Under Rusa 2 Proposed Academic Building For Department Of Instrumentation And Usic Ground Floor At Gauhati University Under Rusa 2
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 24-Jun-2020 | Extension Notice | Date | 01-Jul-2020 |
| 2 | 27-Jun-2020 | 2nd extension Notice | Date | 15-Jul-2020 |
| 3 | 14-Jul-2020 | Extension Notification | Date | 23-Jul-2020 |
| 4 | 21-Jul-2020 | 4th extension notice | Date | 03-Aug-2020 |
BOQ
| Name of Work: PROPOSED ACADEMIC BUILDING FOR DEPARTMENT OF INSTRUMENTATION & USIC [GROUND FLOOR] at GAUHATI UNIVERSITY (UNDER RUSA-2.0) | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | CIVIL WORKS | cc001 | ||
| 2 | 2 | EARTHWORK IN EXCAVATION\nEarthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.\n(A) Up to a depth of 2.00m below the existing ground level.\n(a) In ordinary soil | cc002 | 582 | Cum |
| 3 | 3 | (B) Extra over item no.1.1(A) above for each 1m depth or part thereof beyond the initial depth of 2m | cc003 | 98 | Cum |
| 4 | 4 | Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary.\n(c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading. | cc004 | 285 | Cum |
| 5 | 5 | PLAIN CEMENT CONCRETE WORKS\nPlain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).\n(a) In prop. 1 cement:3 sand : 6 coarse aggregate by volume | cc005 | 32 | Cum |
| 6 | 6 | Plain cement concrete floor base in prop1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. complete. \n(c). 100 mm thick in prop 1:3:6 | cc006 | 385 | Sqm |
| 7 | 7 | Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed. | cc007 | 38 | Sqm |
| 8 | 8 | REINFORCED CEMENT CONCRETE WORKS\nProviding and laying plain/reinforced cement croncrete works cement , coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) \n(I) Using mixture machine\n(A) In sub - structure up to plinth level\nFoundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.\nN) Without using admixture, plasticiser\na) M15 grade concrete or Prop. 1:2:4\n | cc008 | 1 | Cum |
| 9 | 9 | b) M20 grade concrete or Prop. 1:1.5:3 | cc009 | 152 | Cum |
| 10 | 10 | (B) In super-structure from plinth level upto 1st floor level.\n(i) Walls (thickness not less than 100mm) including attached pillasters, buttresses, plinth and string course etc. \nN) Without using admixture, plasticiser\nb) M20 grade concrete or Prop. 1:1.5:3 | cc010 | 15 | Cum |
| 11 | 11 | (ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing.\nN) Without using admixture, plasticiser\nb) M20 grade concrete or Prop. 1:1.5:3 | cc011 | 152 | Cum |
| 12 | 12 | From 1st floor level to 2nd floor level.\n(i) Walls (thickness not less than 100mm) including attached pillasters, buttresses, plinth and string course etc. \nN) Without using admixture, plasticiser\nb) M20 grade concrete or Prop. 1:1.5:3 | cc012 | 2 | Cum |
| 13 | 13 | (ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing.\nN) Without using admixture, plasticiser\nb) M20 grade concrete or Prop. 1:1.5:3 | cc013 | 12 | Cum |
| 14 | 14 | TIMBER SHUTTERING (FORMWORK)\nProviding form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in:\nFoundation, footings, bases of columns, pile cap, raft and mass concrete works etc.\n(b) Using 25mm thick plank | cc014 | 165 | Sqm |
| 15 | 15 | Sides of tie beams, grade beams etc. at or below ground level.\n(b) Using 25mm thick plank | cc015 | 212 | Sqm |
| 16 | 16 | Staircase with sloping or stepped soffits including risers and stringers but excluding Landing. (Using 38mm thick plank) | cc016 | 53.5 | Sqm |
| 17 | 17 | STEEL SHUTTERING:\nProviding formwork using 2mm pressed bend shuttering plate of mild sheet and tubular telescopic steel props including centering, shuttering, strutting and propping etc. complete and removal of the same for in situ reinforced concrete and plain concrete work in:\nColumns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face | cc017 | 211 | Sqm |
| 18 | 18 | Sides and Soffits of Beams, beam haunchings, cantilever girders and bressumers. | cc018 | 484 | Sqm |
| 19 | 19 | Flat Surfaces such as soffits of suspended floors, roofs, landings and the like. | cc019 | 408 | Sqm |
| 20 | 20 | Sloping or Battering sufaces such as sloped slabs etc. including folded plates.\n(a) Where inclination to horizontal plane does not exceed 30o requiring shuttering only on the underside. | cc020 | 85 | Sqm |
| 21 | 21 | Vertical surface such as walls (any thickness), Lift shafts, partitions and the like including attached pilasters, butresses, plinth and string courses and the like. | cc021 | 78 | Sqm |
| 22 | 22 | From 1st floor level to 2nd floor level\nColumns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face | cc022 | 46 | Sqm |
| 23 | 23 | Sides and Soffits of Beams, beam haunchings, cantilever girders and bressumers. | cc023 | 44 | Sqm |
| 24 | 24 | Vertical surface such as walls (any thickness), Lift shafts, partitions and the like including attached pilasters, butresses, plinth and string courses and the like. | cc024 | 25 | Sqm |
| 25 | 25 | MASONRY WORKS\nProviding soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.\n(a).Brick on flat soling. | cc025 | 684 | Sqm |
| 26 | 26 | IN SUB-STRUCTURE.\nBrick work in cement morter with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed \n(I) In Sub-structure up to plinth level.\n(b). In proportion 1:4. | cc026 | 48 | Cum |
| 27 | 27 | IN SUPERSTRUCTURE.\n1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately)\n(A) 112mm thick brick wall\n(a) In cement mortar in proportion 1:4. (1 cement:4 sand) | cc027 | 462 | Sqm |
| 28 | 28 | From 1st floor level to 2nd floor level\n(A) 112mm thick brick wall\n(a) In cement mortar in proportion 1:4. (1 cement:4 sand) | cc028 | 109 | Sqm |
| 29 | 29 | CEMENT CONCRETE FLOORING \n40 mm thick cement concrete floor consisting of 25 mm under layer of cement concrete in prop. 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of 12.5 mm and down) and 15 mm thick wearing layer in cement concrete in prop. 1:1:2 (1cement :1 coarse sand : 2 coarse aggregate of size 10mm down) finished with a floating coat of neat cement finish using cement slurry for bond @ 2.75 kg. per square metre of floor area , wearing layer is to be laid in panels including curing etc. complete as directed. | cc029 | 124 | Sqm |
| 30 | 30 | TILES WORKS\n1. CERAMIC TILES\nA) ON WALLS\nProviding polished ceramic wall Tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls).\nii) Of size 250mmx350mm and above | cc030 | 116 | Sqm |
| 31 | 31 | VITRIFIED TILES\nA) ON FLOOR\nProviding VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/ Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department)\na) Normal range Somany/ Orient /Nitco /Varmora/ VITA/ Marbito/ Make\nii) Of size 600mmx 600mm and above | cc031 | 325 | Sqm |
| 32 | 32 | CONCRETE TILES\n(C) PAVERS\nProviding SUN ROCK HIGH CTS / DEVI paver block/ tiles of concrete grade M30 or above of approved quality, size, shape of specified thickness over a levelling bedding layer of 30mm compacted sand over a base course of WBM or PCC (Base course to be paid separately) including cutting where necessary finished with spreadind, sweeping joining sand and compacting the pavers using vibrating compactor as specified and directed.\nSUN ROCK HIGH CTS /Devi Tiles (Pavers)\n(b) 60 mm thick | cc032 | 55 | Sqm |
| 33 | 33 | MARBLE FLOORING\n18 mm thick marble stone tiles in flooring including risers and treads of steps, skirting, dado, walls, pillars laid with 10 mm thick base of cement plaster in prop.1:3 ( I cement : 3 coarse sand) and jointed with grey cement slurry including rubbing and polishing complete with marble tiles of specified quality and shade at all levels.\n(b) With 18mm thick marble stone tiles of size 600mm x 450 mm, 600mm x 300mm\n(iv) Rajnagar Marble | cc033 | 25 | Sqm |
| 34 | 34 | GRANITE FLOORING\nProviding polished granite tiles of approved quality, size, shape and thickness not less than 18 mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika / Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department)\n(ii) With White cement | cc034 | 36 | Sqm |
| 35 | 35 | Providing polished granite slab of approved quality, size, shape and thickness not less than 18 mm on floors, skirtings, treads and risers of steps over cement mortar bed 15 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile Choksey /Sika/ Pedelite / Rouf) /white cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of slab and as approved and directed by the Department). \n(i) Executive Quality\n(ii) With White cement | cc035 | 4 | Sqm |
| 36 | 36 | ANTISKID TILES\nProviding Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed.\n(A) CERAMIC \ni)Normal range (Sizes 300 mm x 300mm and above)\n(a)Orient made: Galaxy Brown, Galaxy creama, Galaxy Pink, Galaxy Green, Pulsar Beige, Pulsar Blue, Pulsar Dove, Pulsar Pink, Burj Brown, Burj Green, Burj Slate | cc036 | 32 | Sqm |
| 37 | 37 | CEMENT PLASTERING\n10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed.\n(a). In cement mortar 1:4 | cc037 | 1952 | Sqm |
| 38 | 38 | 15 mm thick Cement plaster in single coat on rough side of single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed.\nA) On rough side\n(b). In cement mortar 1:4 | cc038 | 571 | Sqm |
| 39 | 39 | ROOFING\nProviding Pre Painted Galvanized Iron Sheet Roofing (PPGI) at all levels including fitting and fixing with self drilling, self tapping screws complete. (Roof trusses, purlins etc. to be measured and paid separately.) \nTATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement\n(iii) 0.50 mm thick | cc039 | 32 | Sqm |
| 40 | 40 | ROOF TREATMENT\nGrading roof for water proofing treatment with \n(a) Cement concrete 1:2:4 \n(i) 1 cement: 2 coarse sand: 4 graded stone agg. 20 mm nominal size) | cc040 | 2 | Cum |
| 41 | 41 | (b) Cement mortar \n(i) 1:3 (1 cement: 3 coarse sand) | cc041 | 2 | Cum |
| 42 | 42 | BLOCK BOARD SHUTTERS\nProviding and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevent I.S code including oxidised iron butt hinges (100mm x 75mm x 3.5mm) 6 nos with necessary wood screws. \na) Decorative type and block board core.\n(ii) 35 mm thick . | cc042 | 13 | Sqm |
| 43 | 43 | b) Non decorative type and block board core.\n(ii) 35 mm thick . | cc043 | 26 | Sqm |
| 44 | 44 | GRILLS\nProviding, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws.\nI .Plain grill\n(c). Fixed to Brickwork /P.C.C /R.C.C. | cc044 | 625 | kg |
| 45 | 45 | ALUMINIUM DOORS, WINDOWS AND OTHER WORKS\nWINDOWS AND VENTILATORS \nProviding, fitting and fixing anodised aluminium windows and ventilators of standard sections of approved brand without horizontal glazing bars joints mitred and welded (manufactured to relevant IS specifications) fitted with 6mm x 3.15mm lugs 100mm long embedded in CC blocks 150mm x 100mm x 100mm in 1:3:6 mix including providing and fixing handles, frictions stays, joining cleat, bolting device, locking arrangement, spring catch as required complete as specified and directed for all levels. (Cement concrete to be measured and paid separately).\na)Side hung and Top hung windows and ventilators\nii)5mm frosted glass | cc045 | 7 | Sqm |
| 46 | 46 | (b)Fixed windows and ventilators\n(iv) 5 mm clear glass | cc046 | 4 | Sqm |
| 47 | 47 | Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels.\n(a)2 Track sliding window\n(iv) 5 mm clear glass | cc047 | 12 | Sqm |
| 48 | 48 | (b)3 Track sliding window\n(iv) 5 mm clear glass | cc048 | 65 | Sqm |
| 49 | 49 | DOORS\nProviding, fitting and fixing anodised aluminuim framed glazed doors with anodised aluminium frame made of 100mm x 45mm x 2.5mm section of approved brand with door style of size 88mm x 45mm x 2.5mm, top rails 50mm x 45mm x 2mm lock rails 100mm x 45mm x 2mm and bottom rails 100mm x 45mm x 2.5mm fitted with glazing clip, special type rubber gasket complete including hydraulic floor spring, pivot, tower bolt in each leaf, aluminium door handle, lock, angles, cleat etc complete as specified and directed by the department at all levels.\n(v) 5 mm clear glass | cc049 | 10 | Sqm |
| 50 | 50 | F.R.P. DOORS & DOOR FRAMES\nFRP FLUSH DOOR Supplying & fixing of factory made 30mm thick Fibreglass Reinforced Plastic (FRP) panneled door shutter of required colour of FIBREWAYS made with fire retardant grade unsatured polyster resin,moulded to 3mm thick FRP laminate for forming hollow rails and styles,with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings,cast monolithically with 5mm thick FRP laminate for panels and conforming to IS:14856-2000 including fixing to frames complete as per direction of Engineer-in charge. | cc050 | 42 | Rm |
| 51 | 51 | FRP PANNELED DOOR Supplying & fixing of factory made 30mm thick Fibreglass Reinforced Plastic (FRP) panneled door shutter of required colour of FIBREWAYS made with fire retardant grade unsatured polyster resin,moulded to 3mm thick FRP laminate for forming hollow rails and styles,with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings,cast monolithically with 5mm thick FRP laminate for panels and conforming to IS:14856-2000 including fixing to frames complete as per direction of Engineer-in charge. | cc051 | 16 | Sqm |
| 52 | 52 | CEMENT PAINT & PRIMER\na) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth. | cc052 | 2523 | Sqm |
| 53 | 53 | PLASTER OF PARIS & WALL PUTTY\nProviding two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm)\n(i) Thickness = 1.5 mm thick | cc053 | 2523 | Sqm |
| 54 | 54 | WALL PAINTING \nWall painting (two coats) with Plastic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth.\n(a).Plastic Emulsion Paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) | cc054 | 1952 | Sqm |
| 55 | 55 | PAINTING ON WOOD AND WOOD WOOD BASED SURFACES \nApplying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting. \n(b). With ready mixed paint , wood primer (white). | cc055 | 78 | Sqm |
| 56 | 56 | Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping.\n(i).Surfaces over 100mm in width or girth.\nb). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac). | cc056 | 78 | Sqm |
| 57 | 57 | PAINTING ON STEEL AND OTHER METAL SURFACE\nApplying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper.\na). With ready mixed \"red-lead/ red oxide\" primer. | cc057 | 77 | Sqm |
| 58 | 58 | Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter.\n(i).Surfaces over 100mm in width or girth.\nb). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) | cc058 | 77 | Sqm |
| 59 | 59 | EXTERIOR PAINTS / COATINGS\nFinishing old / new wall with water proofing weather coat smooth anti-fungal exterior painting of approved make of Berger paint of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats) | cc059 | 571 | Sqm |
| 60 | 60 | ALUMINIUM FITTINGS\nSupplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished )\na) Sliding door bolts\ni) 300mm x 16mm | cc060 | 22 | each |
| 61 | 61 | b) Tower bolts\nii) 250mm x 12mm | cc061 | 40 | each |
| 62 | 62 | c) Door handles\niii) 150mm | cc062 | 40 | each |
| 63 | 63 | l) Hydraulic door closure | cc063 | 12 | each |
| 64 | 64 | t) Door stopper with rubber stopper | cc064 | 15 | each |
| 65 | 65 | STEEL & IRON WORKS\nREINFORCEMENT\nSupplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.\n(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) \na) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL\n(ii)Super Ductile (SD) TMT reinforcement bars | cc065 | 435 | Qtl |
| 66 | 66 | From 1st floor level to 2nd floor level | cc066 | 45 | Qtl |
| 67 | 67 | ROOF TRUSS\nProviding fitting, hoisting and fixing of roof trusses including purlins fabricated using MS circular hollow section conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed. \na) TATA make Circular Hollow section- CHS of Grade YST-310 conforming to I.S. Specification : 1161-1998 | cc067 | 8 | Qtl |
| 68 | 68 | Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete. | cc068 | 40 | each |
| 69 | 69 | DOOR FRAMES\nProviding, fitting and fixing powder coated pressed steel door frame made of 1.25mm/ 1.6mm thick sheet of various sizes with necessary hinge jamb, lock jamb, head and steel base ties at the bottom of the frame. The whole frame shall be welded or rigidly fixed together by mechanical means with base ties of pressed mild steel angle of size 20x20x1.25mm thick. Frame to be filled up with 1:4:8 P.C.C. after fitting the frame with brick/ concrete works etc.complete as directed by the department for all levels. (P.C.C. to be measured and paid for seperately).\n(a) 1.25mm thick sheet\n(iv) Size 125mm x 60mm (Double rebate) | cc069 | 68 | Rm |
| 70 | 70 | STEEL RAILING\nProviding and fixing Stainless Steel (Grade 304) railing made of hollow tubes, channels, plates etc, including welding, grinding, buffing, polishing and making curvature ( wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i.e. fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc, of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer incharge.(For payment, only weight of stainless steel member is to be considered. No extra payment for fixing accessories such as nuts, bolts, fasteners etc. will be considered.) | cc070 | 52 | kg |
| 71 | 71 | PLINTH PROTECTION WORKS AND DRAINS\nProviding plinth protection 50mm thick to cement concrete 1 : 3 : 6 with coarse agg.of 20mm nominal size including finishing the surface with 10mm thick cement plaster in proportion 1:3 with a floting coat of neat cement finished. | cc071 | 64 | Sqm |
| 72 | 72 | Providing drain with cement concrete (1:3:6) 10cm thick sides 10cm thick bed over brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified.\ni). 300mm wide and average 150mm deep with bed slope 1 in 150 with initial depth of 100mm. | cc072 | 85 | Rm |
| 73 | 73 | PRE CONSTRUCTION ANTI - TERMITE TREATMENT\nPre construction anti - termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.\na) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution. | cc073 | 474 | Sqm |
| 74 | 74 | Pre construction anti - termite treatment by applying in the junction of walls, column with the floor before laying floor and after operation of item no. 26.1.3 above making a channel 30mmx30mm all over the walls and making rod holes @ 150mm apart up to ground level below and applying emulsion @ 11 litres per square meter of vertical plinth wall surface inside the building so as to soak the soil with the emulsion up to the ground level and refill the holes and channel with the original materials obtained in making channels (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.\na) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution. | cc074 | 474 | Sqm |
| 75 | 75 | Pre construction anti - termite treatment by applying the soil along the external perimeter of the building (after construction completed) to a distance close to the plinth wall as specified and as directed by the deptt. up to a depth of 300mm making rod holes along the line @ 150mm apart to a depth of 300mm and applying emulsion @ 4.5 litres per running meter ensure moistening of the soil with emulsion (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.\na) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution. | cc075 | 85 | Rm |
| 76 | 76 | SANITARY AND WATER SUPPLY WORKS | cc076 | ||
| 77 | 77 | INDIAN TYPE WATER CLOSET\nProviding fitting and fixing vitreous water closet squatting pan (Indian type W.C Orissa pattern) with all fittings and fixtures complete including cutting and making good to the walls and floors whereever required. (Flushing Cistern to be paid separately)\nIndian type W.C Orissa pattern of size 580 x 440 mm \n(a) White\niii) Jaquar make | cc077 | 2 | each |
| 78 | 78 | EUROPEAN TYPE WATER CLOSET\nProviding fitting and fixing white vitreous china pedestal type water closet (European type W.C pan 400mm high ) of Parryware / Hindware make with seat and lead ,CP brass hinges and rubber buffers ,10 litre low level PVC flushing cistern with fittings, CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required.\nC) Jaquar make\n(a) White\n(ii) Size 550 x 350 x 360 (Cat No.CNS-WHT-WS02) (inclusive of seat cover) | cc078 | 4 | each |
| 79 | 79 | URINAL\nProviding fitting and fixing vitreous china flat back type lipped front urinal basin of with automatic flushing cistern with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required.\n(B) Hindware Make\n(a) White\n(ii)URINAL ALEXA E-Sense (Cat. No.96005) | cc079 | 4 | each |
| 80 | 80 | SQUATING PLATE URINAL\nProviding fitting and fixing vitreous china squatting plate urinal with automatic flushing cistern with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required.\n(A) Parryware Make \n(i) White (Cat. No. C0503) | cc080 | 2 | each |
| 81 | 81 | AUTOMATIC FLUSHING CISTERN\nSupplying, fiting and fixing automatic flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately)\nii) Hindware make\n(a) White\nAuto Cister 10 litre (Cat. No.C61002) | cc081 | 4 | each |
| 82 | 82 | DIVISION PLATE\nSupplying fiting and fixing vitreous china division plate including fitting and fixing compete as directed and specified. \n(ii) Hindware Make\n(a) White\n(i) Division Plate 680 x 300 (Cat. No.61001) | cc082 | 3 | each |
| 83 | 83 | WASH BASIN\nProviding vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately)\nCounter Top Basin\n(B) Hindware Make\n(iii) Round Starlet 490 dia (Cat. No.10052) | cc083 | 5 | each |
| 84 | 84 | MIRROR\nProviding fitting and fixing Decorative Mirror complete as directed and specified.\n(A) Parryware Make \n(a) Size 800mm x 600mm | cc084 | 4 | each |
| 85 | 85 | SHELF\nProviding fitting and fixing Glass Shelf complete as directed and specified.\nGlass shelf with C.P. guard rail \n(ii) Sona make (Cat. No.TR-0701)\n(b) 525mm | cc085 | 4 | each |
| 86 | 86 | SOAP TRAY,SOAP DISH,LIQUID SOAP DISPENSER AND LIQUID SOAP CONTAINER\nProviding, fitting and fixing recessed soap tray / soap dish complete as directed and specified.\n(a) Parryware Make\n(ii) Wall Soap tray (Cat. No.C9951)\n | cc086 | 4 | each |
| 87 | 87 | TOWEL RAIL,TOWEL RACK & TOWEL RING\nProviding, fitting and fixing CP towel rail complete as directed and specified.\n(a) Jaquar make \n(ii) Continental 600mm (Cat.No. ACN-1111N) | cc087 | 4 | each |
| 88 | 88 | TOILET PAPER HOLDER\nProviding fitting and fixing chrome plated (CP) toilet paper holder of Jaquar make complete as directed and specified.\n(a) Jaquar make \n(iii) Queen's toilet paper holder (Cat.No.AQN-7751) | cc088 | 6 | each |
| 89 | 89 | WASTE COUPLING\nProviding, fitting and fixing Chrome Plated waste coupling complete as directed and specified.\n(a) Jaquar make \n(i) 32mm (HT/FT) (Cat.No.ALD-705 / 709) | cc089 | 5 | each |
| 90 | 90 | BOTTLE TRAP\nProviding, fitting and fixing Chrome Plated bottle trap complete as directed and specified.\n(a) Jaquar make \n(i) Bottle trap (with internal partition) 32mm size with 250mm long wall connection pipe (Cat.No. ALD-769) | cc090 | 5 | each |
| 91 | 91 | PVC PIPES, BENDS, JUNCTIONS, TEES ETC.\nSupplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. \na) In exposed surfaces or in trenches. \n(i) 110mm dia. | cc091 | 30 | Rm |
| 92 | 92 | (iv) 75mm dia. | cc092 | 35 | Rm |
| 93 | 93 | b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.\n(i) 110mm dia. | cc093 | 40 | Rm |
| 94 | 94 | (iv) 75mm dia. | cc094 | 50 | Rm |
| 95 | 95 | Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. \na) In exposed surfaces or in trenches. \n(i) 110mm dia. | cc095 | 12 | each |
| 96 | 96 | (iv) 75 mm dia. | cc096 | 10 | each |
| 97 | 97 | (b) Concealed by chiselling or breaking brick wall/C.C/R.C.C. and making good to the damages.\n(i) 110mm dia. | cc097 | 15 | each |
| 98 | 98 | (iv) 75 mm dia. | cc098 | 15 | each |
| 99 | 99 | Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/ Prince) or other ISI approved including joining, fitting and fixing etc.as necessary complete at all levels including below G.L. as directed and specified.\na) In exposed surfaces or in trenches.\n(ii) 110mm dia. | cc099 | 10 | each |
| 100 | 100 | (iv) 75 mm dia. | cc100 | 10 | each |
| 101 | 101 | (b) Concealed by chiselling or breaking brick wall/C.C/R.C.C. and making good to the damages.\n(i) 110mm dia. | cc101 | 12 | each |
| 102 | 102 | (iv) 75 mm dia. | cc102 | 8 | each |
| 103 | 103 | Supplying fiting and fixing 45degree PVC bend of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. \na) In exposed surfaces or in trenches. \n(ii) 110mm dia. | cc103 | 8 | each |
| 104 | 104 | (iv) 75 mm dia. | cc104 | 6 | each |
| 105 | 105 | (b) Concealed by chiselling or breaking brick wall/C.C/R.C.C. and making good to the damages.\n(ii) 110mm dia. | cc105 | 8 | each |
| 106 | 106 | (iv) 75 mm dia. | cc106 | 6 | each |
| 107 | 107 | Supplying fiting and fixing PVC Plain single tee of (Supreme/ Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. \na) In exposed surfaces or in trenches. \n(ii) 110mm dia. | cc107 | 15 | each |
| 108 | 108 | (iv) 75 mm dia. | cc108 | 12 | each |
| 109 | 109 | (b) Concealed by chiselling or breaking brick wall/C.C/R.C.C. and making good to the damages.\n(ii) 110mm dia. | cc109 | 15 | each |
| 110 | 110 | (ii) 90mm dia. | cc110 | 12 | each |
| 111 | 111 | Supplying fiting and fixing PVC single ‘Y’ of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. \na) In exposed surfaces or in trenches. \n(ii) 110mm dia. | cc111 | 15 | each |
| 112 | 112 | (iv) 75mm dia. | cc112 | 12 | each |
| 113 | 113 | (b) Concealed by chiselling or breaking brick wall/C.C/R.C.C. and making good to the damages.\n(ii) 110mm dia. | cc113 | 12 | each |
| 114 | 114 | (iv) 75 mm dia. | cc114 | 12 | each |
| 115 | 115 | COWEL\nProviding fitting and fixing 50mm dia. HCI cowel with cement caulking complete as directed and specified. | cc115 | 10 | each |
| 116 | 116 | GRATING\nProviding fiting & fixing C.P.Grating to the floors complete as directed and specified.\n(a) 110mm dia | cc116 | 15 | each |
| 117 | 117 | MANHOLE COVER\nProviding fitting and fixing (600x600)mm 90mm thick C.I. Man hole cover and frame of 25 Kg. weight complete as directed and specified | cc117 | 10 | each |
| 118 | 118 | SOAK PIT AND INSPECTION CHAMBER\nConstruction of filter bed in soak pit including earth work in excavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C. plain sheet above brick bat filling complete as directed. (sizes of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of users as mentioned in the table. | cc118 | 2 | Cum |
| 119 | 119 | Construction of inspection pit inside measurement 450mm x450mm x450mm flush with 100mm diameter HCI/PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling, 12cm brick wall in cement mortar in proportion 1:4 finished with 13mm cement plaster in proportion 1:2 in side wall and floor. 450mm x450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pit as directed. | cc119 | 10 | each |
| 120 | 120 | PIPING\nSupplying fitting and fixing SFMC (SAVOIR-FAIRE MANUFACTURING CO. PVT.LTD.) brand 3 layered (outer green coloured, UV Stabilised, middle black coloured and inner white coloured (with antimicrobial property) fusion welded P.P.R (Polypropelene Random Co-Polymer) pipes of following size with all necessary fitting such as bend , tee, elbow, reducer, plug and clamp etc. complete at all levels as directed and specified.\n(i) In exposed surface or trenches\n(b) 20 mm OD (PN-16) SFMC brand 3 layer P.P.R. pipe | cc120 | 25 | Rm |
| 121 | 121 | (c) 25 mm OD (PN-16) SFMC brand 3 layer P.P.R. pipe | cc121 | 45 | Rm |
| 122 | 122 | (e) 40 mm OD (PN-16) SFMC brand 3 layer P.P.R. pipe | cc122 | 40 | Rm |
| 123 | 123 | AJAY FLOWGUARD CPVC PIPE\nSupplying fitting and fixing Ajoy Flowguard CPVC (Chlorinated Polyvinyl Chloride) pipes having thermal stability for hot and cold water supply including all CPVC plain and bruss threaded fitting including clamps at 1.00 m spacing including joining of pipes and fitting with one step CPVC solvent cement and testing of joints complete at all levels as directed and specified.\n(Note: Ball valve and union will be charged extra and does not comes under Accessories)\nII) Concealed by chieselling or breaking brick wall/ C.C. wall/ R.C.C. wall and making good to the damaged structure.\nc) 20mm dia\ni) Using Tata (medium) | cc123 | 80 | Rm |
| 124 | 124 | d) 15 mm dia\ni) Using Tata (medium) | cc124 | 60 | Rm |
| 125 | 125 | BIB COCK\nSupplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) \nI) Essco make (Delux/Sumthing spl./Tropical) \n(a) Bib cock short body | cc125 | 7 | each |
| 126 | 126 | STOP COCK\nSupplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified (G.I. & C.P. pipes will be measured and paid separately)\nI) Brass stop cock (heavy) of Sant make\n(i)15mm dia | cc126 | 15 | each |
| 127 | 127 | (ii)20mm dia | cc127 | 12 | each |
| 128 | 128 | (iii) 25mm dia | cc128 | 12 | each |
| 129 | 129 | PILLAR COCK\nSupplying and fitting fixing C.P. pillar cock of 15mm dia of approved brand as specified and directed. \nI) Agmeco (classic) \n(a) Flat | cc129 | 5 | each |
| 130 | 130 | VALVE\nSupplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed.\nb) 40 mm dia. | cc130 | 4 | each |
| 131 | 131 | c) 25 mm dia. | cc131 | 4 | each |
| 132 | 132 | Supplying and fitting ball valve as specified and directed..\na) 25 mm dia. (gun metal) | cc132 | 4 | each |
| 133 | 133 | b) 20mm dia. (gun metal) | cc133 | 4 | each |
| 134 | 134 | WATER TANK\nSupplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes\n(I) 2000 litre capacity \n(a) Sintex make | cc134 | 1 | each |
| 135 | 135 | EXTERNAL WATER SUPPLY WORKS\nPIPING\nSupplying fitting and fixing Pipes with all necessary fittings in exposed or in trenches including trenching and refilling the same etc complete as directed.\nA) G.I pipe with GI fitting\na) TATA/SAIL (Medium)\niii) 25mm diameter | cc135 | 25 | Rm |
| 136 | 136 | iv) 32mm diameter | cc136 | 30 | Rm |
| 137 | 137 | v) 40mm diameter | cc137 | 50 | Rm |
| 138 | 138 | Neat Cement Punning | cc138 | 70 | Sqm |
| 139 | 139 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes.\n110 mm diameter | cc139 | 50 | Metre |
| 140 | 140 | Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.\nCoupler\n110 mm | cc140 | 6 | each |
| 141 | 141 | Bend 87.5°\n110 mm bend | cc141 | 8 | each |
| 142 | 142 | Shoe (Plain)\n110 mm bend | cc142 | 8 | each |
| 143 | 143 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.\n110 mm | cc143 | 25 | each |
| 144 | 144 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. | cc144 | 8 | each |
| 145 | 145 | ELECTRICAL WORKS | cc145 | ||
| 146 | 146 | Wiring in surface/ recessed PVC conduit FR (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) cable\nCIRCUIT WIRING\nWiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system.\nWith 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. | cc146 | 600 | Rm |
| 147 | 147 | With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. | cc147 | 60 | Rm |
| 148 | 148 | With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. | cc148 | 120 | Rm |
| 149 | 149 | With 2 x 10 sq. mm. + earth continuity with 1x 6 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. | cc149 | 50 | Rm |
| 150 | 150 | Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system.\nWith 4 x 16 sq. mm. + earth continuity with 2x10 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. | cc150 | 30 | Metre |
| 151 | 151 | Wiring for 5 pin 6 amp plug with 1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) including 5 pin 6 amp socket outlet (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) and 6 amp flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) earthing the 3rd pin of the socket as required on the switch board in surface/ recessed P.V.C. conduit wiring system. When fitted on same board of light and fan. | cc151 | 24 | each |
| 152 | 152 | Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete.\nMedium point up to 6.00 metre. Length. | cc152 | 16 | each |
| 153 | 153 | Long point up to 10.00 metre. Length. | cc153 | 16 | each |
| 154 | 154 | Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.)\nLong point up to 10.00 metre. Length. | cc154 | 13 | each |
| 155 | 155 | Wiring for light/fan/call bell point with 3x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) ceiling rose etc. complete\n Short point up to 3.00 metre. length. | cc155 | 35 | each |
| 156 | 156 | Medium point up to 6.00 metre. Length. | cc156 | 42 | each |
| 157 | 157 | Long point up to 10.00 metre. Length. | cc157 | 30 | each |
| 158 | 158 | MODULAR SWITCH \nSupplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE in surface/ recessed system complete as per direction of department.\n1-2 module type Metal | cc158 | 48 | each |
| 159 | 159 | 3 module type Metal | cc159 | 11 | each |
| 160 | 160 | 4-5 module type Metal | cc160 | 10 | each |
| 161 | 161 | 6-8 module type Metal | cc161 | 23 | each |
| 162 | 162 | 10 module type Metal | cc162 | 1 | each |
| 163 | 163 | 12-16 module type Metal | cc163 | 1 | each |
| 164 | 164 | 24 module type Metal | cc164 | 4 | each |
| 165 | 165 | Supplying including fitting fixing of following front plate of suitable colour MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE as per direction of department.\n1 module | cc165 | 4 | each |
| 166 | 166 | 2 module | cc166 | 44 | each |
| 167 | 167 | 3 module | cc167 | 11 | each |
| 168 | 168 | 4 module | cc168 | 2 | each |
| 169 | 169 | 5 module | cc169 | 8 | each |
| 170 | 170 | 6 module | cc170 | 21 | each |
| 171 | 171 | 8 module | cc171 | 2 | each |
| 172 | 172 | 10 module | cc172 | 1 | each |
| 173 | 173 | 16 module | cc173 | 1 | each |
| 174 | 174 | 24 module | cc174 | 4 | each |
| 175 | 175 | Supplying with fitting and fixing of Single Phase Modular Motor Starter switch MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department.\nModular Motor Starter switch Relay Range 16 - 25 Amps in 3 Module | cc175 | 5 | each |
| 176 | 176 | Supplying including fitting and fixing of TV co-axial outlet MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department. | cc176 | 2 | each |
| 177 | 177 | Supplying with fitting and fixing of RJ-11 Telephone jack MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department. | cc177 | 2 | each |
| 178 | 178 | Supplying with fitting and fixing of CAT 6 RJ-45 Computer jack in one module MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department. | cc178 | 32 | each |
| 179 | 179 | Supplying with fitting fixing of blank plate single in modular switch system MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE complete as per direction of department. | cc179 | 10 | each |
| 180 | 180 | Supplying with fitting and fixing of 100 watt electronic modular fan speed controller 4 - Step 2 - module type MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department. | cc180 | 20 | each |
| 181 | 181 | Supplying with fitting fixing of 6 amp one way modular clip in bell push with LED MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department. | cc181 | 5 | each |
| 182 | 182 | Supplying including installation of socket outlet 6/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department. | cc182 | 13 | each |
| 183 | 183 | Supplying including installation of socket outlet 6 Amps 3 pin combine shuttered complete , MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department. | cc183 | 56 | each |
| 184 | 184 | Supplying with fitting fixing of 16 amp one way modular clip in switch, MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department. | cc184 | 13 | each |
| 185 | 185 | Supplying with fitting fixing of 6 amp one way modular clip in switch, MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department. | cc185 | 158 | each |
| 186 | 186 | FITTINGS AND ACCESSORIES (ALL PRODUCTS SHOULD BE ENERGY EFFICIENT AND ENVIRONMENT FRIENDLY)\nSupplying and fixing of Call bell ( Buzzer ) including 6 amp capacity flush type bell push switch including connection as approved by the Deptt.)as required. [CB] | cc186 | 5 | each |
| 187 | 187 | SUPPLY AND FIXING OF RIGID PVC CONDUIT (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) IN SURFACE AND RECESS WIRING SYSTEM\nSupply and fixing 19 mm dia 2.00mm average wall thickness heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in recessed system including cutting the wall and making good the same as required: | cc187 | 300 | Metre |
| 188 | 188 | Wiring with P.V.C. insulated unsheathed 1.1 K.V. grade single core copper conductor FR cable in existing surface/ recessed conduit wiring system\nWiring for Co - axial Jelly Flooded (Unarmoured) (FINOLEX /RR KABEL /NICCO / ANCHOR make) cable in existing surface conduit wiring system including connection etc as required.\nCo - axial Jelly Flooded (Unarmoured) RG 6 (Copper) | cc188 | 60 | Metre |
| 189 | 189 | EPABX\nSupplying ,installation, testing & commissioning of 2 pair Unarmoured Telephone Cable through existing conduit in surface/ recess system. | cc189 | 60 | Metre |
| 190 | 190 | SWITCH GEAR & PROTECTION\nINDUSTRIAL SOCKETS, DB WITHOUT MCB & MCCB , MCB, RCCB, RCBO, SFU, CHANGE OVER ETC. (C&S, Havells, INDOASIAN, HPL OR EQUIVALENT as approved by the Deptt.)MAKE)\nSupplying fitting and fixing industrial Plug & Socket in surface mounting SPN sheet steel powder painted MCB DB incorporated with MCB DIN rail, neutral link Earth bar of the following rating of DP MCB complete with making necessary connection etc. as specified and directed by the Deptt.\n20A Capacity. (C&S, Havells, INDOASIAN, HPL or equivalent as approved by the Deptt.) make) | cc190 | 5 | each |
| 191 | 191 | MCB DB (ABB, SCHNEIDER MG, LEGRAND, HAGER MAKE) & (SCHNEIDER NEO BREAK, C&S, Havells, INDOASIAN, HPL OR EQUIVALENT MAKE AS PPROVED BY THE DEPTT.)\nMCB IN-comer SPN DB\nSupplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. \nABB, Schneider MG, legrand, Hager make)\n12 way SPN Double Door | cc191 | 5 | each |
| 192 | 192 | MCB IN-comer TPN (Horizontal DB)\nSupplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt.\nABB, Schneider MG, legrand, Hager make)\n8 way TPN (4+24) double door \n | cc192 | 1 | each |
| 193 | 193 | MCB IN-comer (TPN VERTICAL DB)\nSupplying with fitting and fixing MCCB income and MCB outgoing sheet steel, phosphatised, powder painted double door IP-43 surface mounting vertical TPN MCB DB incorporated with bas-bar up to 250A, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt.\nABB, Schneider MG, legrand, Hager make)\n4 way TPN (4+12) double door | cc193 | 1 | each |
| 194 | 194 | MCB, MCCB, RCCB, RCBO (ABB, SCHNEIDER MG, LEGRAND, AND HAGER MAKE) & (SCHNEIDER NEO BREAK, C&S, Havells, INDO ASIAN, HPL OR EQUIVALENT MAKE AS PPROVED BY THE DEPTT.) MCB (Conform to IS / IEC 60898-1:200/ MCCB (Conform to IS/IEC 60947- RCCB (Conform to IS/IEC 12640 / 61008)\nSupplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.\nC Series\n(Schneider MG, legrand, Hager make)\n6 to 32A | cc194 | 70 | each |
| 195 | 195 | 40A | cc195 | 3 | each |
| 196 | 196 | Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.\nC Series\n(ABB, Schneider MG, legrand, Hager make)\n6 to 32A | cc196 | 3 | each |
| 197 | 197 | 40A | cc197 | 2 | each |
| 198 | 198 | Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DP RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.\n100/300mA sensitivity DP RCCB\n(ABB, Schneider MG, legrand, Hager make)\n25A | cc198 | 3 | each |
| 199 | 199 | 40A | cc199 | 2 | each |
| 200 | 200 | Supplying with fitting and fixing TP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.\nC Series (ABB, Schneider MG, legrand, Hager make)\n63A | cc200 | 1 | each |
| 201 | 201 | Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.\nC Series (ABB, Schneider MG, legrand, Hager make)\n63A | cc201 | 1 | each |
| 202 | 202 | Supplying with fitting and fixing panel mounting open execution 25 KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure of the following capacity complete with making necessary connection as approved by the Deptt. as specified and directed by the deptt.\n25 KA 415V 50 Hz 4P MCCB \n(Schneider, legrand, Siemens make)\n125A | cc202 | 1 | each |
| 203 | 203 | EARTHING \nSupply, installation & testing of G.I. earth station with perforated 40 mm dia and 4.50 Metre long heady duty G.I. pipe with necessary 40 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt . | cc203 | 2 | each |
| 204 | 204 | Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt. | cc204 | 2 | each |
| 205 | 205 | Supply, installation & testing of Copper Plate earth station with 600 mmx600 mmx3 mm copper earth plate with necessary 40 mm dia. G.I. medium duty watering pipe with G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement with 300 mmx300 mmx6 mm C.I. hinged cover plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt . | cc205 | 1 | Set |
| 206 | 206 | Extra for using salt (5 K and Charcoal (96 K in G.I./Copper plate Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the deptt . | cc206 | 1 | Set |
| 207 | 207 | Supplying & laying of 6 SWG G.I. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt. | cc207 | 70 | Metre |
| 208 | 208 | Supplying & laying of 25X5mm size G.I. strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of G.I. nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt. | cc208 | 30 | Rm |
| 209 | 209 | Supplying & laying of 25X5mm size Copper strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of Brass nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt. | cc209 | 15 | Rm |
| 210 | 210 | CEILING FAN, EXHAUST FAN AND AIR CURTAIN\nSupplying including fitting fixing of following A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department [Without regulator].\nHigh speed 1050 mm Sweep (ORIENT PSPO make) [FF] | cc210 | 4 | each |
| 211 | 211 | Standard model 1200 mm Sweep Usha make)/ Standard model 1050 / 1200 mm Sweep Havells make)/ High speed 1200 mm sweep (ORIENT PSPO make) [F] | cc211 | 16 | each |
| 212 | 212 | Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department.\nDomestic\nVentil Air DB 300 mm sweep (Havells make) [EF] | cc212 | 5 | each |
| 213 | 213 | Supplying including fitting fixing of following A.C. Wall fan in the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department.\n(CROMPTON /ORIENT/Havells/USHA or equivalent make)\nStriker HI- Speed , 400 mm sweep Usha make) / Wind flow with plastic blade 400 mm sweep Crompton make). [ WF ] | cc213 | 8 | each |
| 214 | 214 | INVERTER/ UPS AND RACK FOR LAN WORKS/ LAN WORKS/ AVR\nSupply, installation testing and commissioning of following LAN networks equipments.\nSolid Copper Cable Cat 6, 4 pair, UTP - 305m SCHNEIDER/LEGRAND or equivalent make as approved by the Deptt.. | cc214 | 2.5 | each |
| 215 | 215 | U. G. CABLE AND CABLE WORKS\nSupply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) .\n 3 & 1/2 Core A2XFY\n120.00 Sq. mm.3 & 1/2 Core armoured U.G. cable \n | cc215 | 40 | Metre |
| 216 | 216 | Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch, through medium duty G.I. pipe (Tata/ Nezone make or equivalent as approved by the Deptt) bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make)\nCore - 3 & 1/2 A2XWY A2XFY\n 120.00 Sq.mm 3&1/2 Core U.G. cable in 65 mm dia medium duty hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.) | cc216 | 10 | Metre |
| 217 | 217 | ITEMS APPROVED BY THE CHIEF ENGINEER P.W.D. (Bldg.), ASSAM, CHANDMARI, GUWAHATI-3 ON DATED 09-09-2019\nSupplying, installation, testing and Commission of the following indoor Decorative Surface mounted 2' x 2' LED down lighter luminaries of model no-SM365C LED 32 -6500 PSU OD GR / SM365C LED 32 -6500 PSU OD GH / SM365C LED 32 -6500 PSU OD GR /SM365C LED 32 -6500 PSU OD WH/ LSVR01S036SC / LSVR01S0365SN / LSVR01S0365SW/ CRCO10S038HP57G1 complete with all accessories such as ballast, starter etc. In the false ceiling type Armstrong /Gypsum or similar ceiling mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department ( Philips / Jaquar / Wipro make). [CLT] | cc217 | 12 | each |
| 218 | 218 | Supplying, fitting fixing of LED Batten Tubes high quality aluminium extruded with decorative end caps connection with 1.5 Sq.mm 1 core PVC insulated round copper conductor as required and as directed by the department.\nb) BN021C LED 20 PSU CW GR S2 [TL] | cc218 | 30 | each |
| 219 | 219 | Supplying, fitting fixing of LED Batten Tubes high quality aluminium extruded with decorative end caps connection with 1.5 Sq.mm 1 core PVC insulated round copper conductor as required and as directed by the department.\nc) LGLZ0 1 X 010XC / LGLZ0 1 X 010XCN /LGLZ0 1 X 010XCW ( 10 W). [FL] | cc219 | 18 | each |
| 220 | 220 | Supplying, installation, testing and Commission of the following indoor Decorative Recess mounted LED down lighter luminaries of model no-LESP01R009XC / LESP01R009XN /LESP01R009XW / L00957R000 / L00940R000 / L00930R000 /LD90-111 - XXX-65-XX complete with all accessories such as ballast, starter etc. In the false ceiling type Armstrong /Gypsum or similar ceiling mounting with necessary support with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department ( Jaquar / LT / Wipro make). [CL] | cc220 | 15 | each |
| 221 | 221 | Supplying,installation,testing and commissioning of pressure die cast powder coated aluminium alloy housing frosted PC diffuser, IP65/IP66 protection of the following street light including connection with 2.5 Sq.mm. 3 core PVC insulated round copper conductor as required and as directed by the department. \na) BRP 409 LED CW 036 MR FG S1 PSU GR [CH]\n | cc221 | 3 | each |
| 222 | 222 | SECONDARY LIGHT POINT\nWiring for secondary light point with 1.5 sq mm insulated (ISI or equivalent) HFFR Copper Conductor Cable in recessed P.V.C. conduit of as required with ceiling rose as directed by the department. | cc222 | 9 | each |
| 223 | 223 | Supply, Fitting Fixing of Shock Treatment Chart | cc223 | 2 | each |
| 224 | 224 | SITE DEVELOPMENT | cc224 | ||
| 225 | 225 | Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary forest royelty, sales tax, land compensation, municipal gate fees, if any monopoly duty etc. (profile measurement to be taken and 12.5% deduction for shrinkage to be made from total quantity) etc. complete as directed and specified.\n(b) Other than Guwahati city | cc225 | 1800 | Cum |
| 226 | 226 | Surface dressing of ground including removing vegitation and/ or undulation of ground not exceeding 150mm deep and disposal of rubbish outside the periphery and lift up to 1800mm in all kinds of soil. | cc226 | 1200 | Sqm |
| 227 | 227 | Felling and removing\nc). Cutting trees including uprooting and removing where necessary.\n(i).500 mm to 1000mm girth. | cc227 | 10 | each |
| 228 | 228 | (ii).1000 mm to 1500mm girth. | cc228 | 15 | each |
| 229 | 229 | (iii).1500 mm to 1800mm girth. | cc229 | 25 | each |
| 230 | 230 | COMPOUND WALL | cc230 | ||
| 231 | 231 | EARTHWORK IN EXCAVATION\nEarthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.\n(A) Up to a depth of 2.00m below the existing ground level.\n(a) In ordinary soil | cc231 | 355 | Cum |
| 232 | 232 | PLAIN CEMENT CONCRETE WORKS\nPlain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).\n(a) In prop. 1 cement:3 sand : 6 coarse aggregate by volume | cc232 | 12 | Cum |
| 233 | 233 | REINFORCED CEMENT CONCRETE WORKS\nProviding and laying plain/reinforced cement croncrete works cement , coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) \nI) Using mixture machine\nA) In sub - structure up to plinth level\nFoundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.\nN) Without using admixture, plasticiser\nb) M20 grade concrete | cc233 | 36.5 | Cum |
| 234 | 234 | B) In super-structure from plinth level upto 1st floor level.\nii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing.\nN) Without using admixture, plasticiser\nb) M20 grade concrete | cc234 | 32 | Cum |
| 235 | 235 | TIMBER SHUTTERING (FORMWORK)\nProviding form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in:\nSides of tie beams, grade beams etc. at or below ground level.\nb)Using 25mm thick plank | cc235 | 240 | Sqm |
| 236 | 236 | Columns, Pillars, Posts & Strut\na)Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face\ni) Using 38mm thick plank | cc236 | 180 | Sqm |
| 237 | 237 | Vertical ties, fins, sun breaker, louvers, bands, dropwalls etc.\n(ii) Using 25mm thick plank | cc237 | 225 | Sqm |
| 238 | 238 | MASONRY WORKS\nProviding soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.\n(a).Brick on flat soling. | cc238 | 195 | Sqm |
| 239 | 239 | IN SUPERSTRUCTURE.\n1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately)\n(A) 112mm thick brick wall\n(a) In cement mortar in proportion 1:4. \n(1 cement:4 sand) | cc239 | 515 | Sqm |
| 240 | 240 | (C) PAVERS\nProviding polished tiles of approved quality, size, shape of specified thickness on pavers over a base of 100mm compacted sand gravel including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). \n(A) SUN ROCK HIGH CTS Tiles (Pavers)\n(a) Silicon (Pavers) 60 mm thick | cc240 | 241.5 | Sqm |
| 241 | 241 | CEMENT PLASTERING\n10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed.\n(a). In cement mortar 1:4 | cc241 | 891 | Sqm |
| 242 | 242 | 15 mm thick Cement plaster in single coat on rough side of single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. \nA) On rough side\n(b). In cement mortar 1:4 | cc242 | 515 | Sqm |
| 243 | 243 | GRILLS\nProviding, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flats , M.S. Square /Rectangular Section at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws, one coat steel primer paint.\nI . Ornamental grill (as per approved design)\n(c). Fixed to Brickwork /P.C.C /R.C.C. | cc243 | 675 | kg |
| 244 | 244 | Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter.\n(i).Surfaces over 100mm in width or girth.\nb). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) | cc244 | 24 | Sqm |
| 245 | 245 | Finishing old/ new wall with water proofing weather coat smooth anti-fungal exterior painting of Apex brand of Asian Paints and of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats) | cc245 | 1782 | Sqm |
| 246 | 246 | Supplying, fitting and fixing double leaf heavy duty iron gate, frame made from 40mm x 40mm x 6mm M.S. angle and with M.S. flat of 40mm x 6mm size as per approved design.Necessary locking arrangement for temporary closing the gate and 2nos.( minimum) strong iron hinges of M.S bars and flat of same sizes on each leaf to be embedded in C.C brick pillers as necessary including a red oxide painting to all iron works as directed and specified.(Separate payment will be made for posts). \n | cc246 | 25 | Sqm |
| 247 | 247 | STEEL & IRON WORKS\nREINFORCEMENT\nSupplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.\n(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) \na) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL\n(ii)Super Ductile (SD) TMT reinforcement bars | cc247 | 41 | Qtl |
| 248 | 248 | COMPOUND DRAIN | cc248 | ||
| 249 | 249 | INTERNAL DRAIN\nPLAIN CEMENT CONCRETE WORKS\nPlain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).\n(b) In prop 1cement:3 sand :6 coarse aggregate by volume | cc249 | 18 | Cum |
| 250 | 250 | MASONRY WORKS\nProviding soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.\n(a).Brick on flat soling. | cc250 | 156 | Sqm |
| 251 | 251 | IN SUB-STRUCTURE.\nBrick work in cement morter with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed \n(I) In Sub-structure up to plinth level.\n(b). In proportion 1:4. | cc251 | 35 | Cum |
| 252 | 252 | 15 mm thick Cement plaster in single coat with hardener of Recron/ Degusa/ Fosroc on brick/concrete for plastering including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. \n(a) In cement mortar 1:3 | cc252 | 175 | Sqm |
| 253 | 253 | Neat Cement Punning | cc253 | 175 | Sqm |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-4 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender