( Sl . No . 03 ) Naya Moradabad Sector 13 Estith Office Me Naya V R F Air Conditioning System Lagwaye Jane Purane Office Se Purane 13 Nos Split Ac 1 . 5 Ton 2 Ton Naye Office Me Esthapit Kiye Jane Ka Work, MORADABAD-Uttar Pradesh

Moradabad Development Authority has published ( Sl . No . 03 ) Naya Moradabad Sector 13 Estith Office Me Naya V R F Air Conditioning System Lagwaye Jane Purane Office Se Purane 13 Nos Split Ac 1 . 5 Ton 2 Ton Naye Office Me Esthapit Kiye Jane Ka Work. Submission Date for this Tender is 11-06-2020. Air Conditioner Tenders in MORADABAD Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

24468125
( Sl . No . 03 ) Naya Moradabad Sector 13 Estith Office Me Naya V R F Air Conditioning System Lagwaye Jane Purane Office Se Purane 13 Nos Split Ac 1 . 5 Ton 2 Ton Naye Office Me Esthapit Kiye Jane Ka Work
Open Tender
Indian
Uttar Pradesh
MORADABAD
11-06-2020

Tender Details

( Sl . No . 03 ) Naya Moradabad Sector 13 Estith Office Me Naya V R F Air Conditioning System Lagwaye Jane Purane Office Se Purane 13 Nos Split Ac 1 . 5 Ton 2 Ton Naye Office Me Esthapit Kiye Jane Ka Work

Key Value

Document Fees
INR 590 /-
EMD
INR 75000.0 /-
Tender Value
INR 37.27 Lakhs /-

BOQ Items

Name of Work: u;k eqjknkckn lsDVj&13 fLFkr dk;kZy; esa u;k oh0vkj0,Q0 ,;j daMh'kfuax fLkLVe yxk;s tkus o iqjkus dk;kZy; ls iqjkus 13 ux fLifyV ,0lh0 ¼1-5 Vu o 2-00 Vu½ u;s dk;kZy; esa LFkkfir fd;s tkus dk dk;ZA
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Outdoor Units-Heat Pump (R410A)-N. Cap.
2 1.01 Supply of VRF rerigerant flow type airconditioning system complete with indoor and Outdoor units with individual controller as per detail given in specifications Carrier/Daikin/Hitachi Makes VRF airconditioning system (equipments) and having following items: complete in all respect......... as per direction of E/I (II) ODU - 20 HP Heating and cooling. 2 Nos
3 1.02 Outdoor Units-Heat Pump (R410A)-N. Cap.
4 1.03 Fixing of Wall Mounted Unit 2.03 TR 1 Nos
5 1.04 Fixing of Medium Static Duct Type 3.2 TR 1 Nos
6 1.05 Fixing of Wall Mounted Unit 2.56 TR 1 Nos
7 1.06 Fixing of Wall Mounted Unit 2.28 TR 3 Nos
8 1.07 Fixing of Wall Mounted Unit 1.29 TR 1 Nos
9 1.08 Fixing of High Static Duct Type 8.0 TR IDU 1 Nos
10 1.09 Fixing of High Static Duct Type 5.8 TR IDU 2 Nos
11 1.1 Fixing of Refnets. complete in all respect......... as per direction of E/I 8 Nos
12 1.11 ikVZ&, ds enks dh LFkkiuk dk dk;ZA Part-B
13 1.12 Fixing of Variable Refrigerant Volume System Outdoor Unit- Lifting, shifting, positioning, vaccumising, gas charging, installation, testing & commissioning of below mentioned outdoor units. complete in all respect......... as per direction of E/I (A)ODU - 20 HP Heating and cooling. 2 Nos
14 1.13 Fixing of Indoor Unit- Lifting, shifting, positioning & installation of below mentioned indoor unit. complete in all respect......... as per direction of E/I (A) Ductable units 3 Nos.
15 1.14 Hiwall units 4 Nos.
16 1.15 Fixing of Refrigerant Piping- Interconnecting refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. complete in all respect......... as per direction of E/I 210 Rmt
17 1.16 Electric work
18 1.17 Supply, Installation, Testing and Commissioning of control cum transmission wiring of 2 corex1.5 sq mm copper cable between indoor & outdoor units. complete in all respect......... as per direction of E/I 280 Rmt
19 1.18 Supply, Installation, Testing and Commissioning of power wiring of 4 corex10 sq mm copper cable between panel to outdoor units. complete in all respect......... as per direction of E/I 180 Rmt
20 1.19 Supply, Installation, Testing and Commissioning of power wiring of 2 core x 1.5 sq mm copper cable between panel to indoor units. complete in all respect......... as per direction of E/I 280 Rmt
21 1.2 Supply, Installation, Testing and Commissioning of Earth wiring transmission wiring of 4 sq mm copper cable between panel to outdoor units. complete in all respect......... as per direction of E/I 180 Rmt
22 1.21 Ducting:
23 1.22 Supplying, installation, testing and\ncommissioning of GI ducting and other\naccessories complete as required. complete in all respect......... as per direction of E/I ( A)24 Gauge GI Ducting 1000 sqft
24 1.23 Accoustic Insulation in Ducts
25 1.24 Accoustic Insulation with 50mm thick glass\nwool covered with RP Tissue paper &then 30\nguage perforated al. sheet to be hoIded by nut\nbolts. complete in all respect......... as per direction of E/I 240 sqft
26 1.25 Thermal Insulation on Ducting
27 1.26 Providing and fixing duct rubber nitrile\ninsulation with 10 mm thick. complete in all respect......... as per direction of E/I 760 sqft
28 1.27 Grill/Diffusers
29 1.28 Providing and fixing duct rubber nitrile\ninsulation with 10 mm thick and with\naluminium foil. complete in all respect......... as per direction of E/I (A) Supply & return air grill. complete in all respect......... as per direction of E/I 1 Sqmtr
30 1.29 Canvass connection
31 1.3 Providing & fixing of flexible connection\nbetween each duct type indoor unit and\nducting complete as required. complete in all respect......... as per direction of E/I 4 NOS
32 1.31 S/F of Weather proof isolater. complete in all respect......... as per direction of E/I 2 NOS
33 1.32 Drain pipe
34 1.33 Supply, Installation, Testing and Commissioning of drain pipe PVC hard 25mm. complete in all respect......... as per direction of E/I 120 RMT
35 1.34 Supply, Installation, Testing and Commissioning of drain pipe PVC hard 35mm. complete in all respect......... as per direction of E/I 90 RMT
36 1.35 Civil work
37 1.36 S/F of Chaise cutting refiling 4" . complete in all respect......... as per direction of E/I 150 RMT
38 1.37 S/F of Chaise cutting refiling 3" . complete in all respect......... as per direction of E/I 200 RMT
39 1.38 S/F of Lenter cutting. complete in all respect......... as per direction of E/I 120 SQFT
40 1.39 Wood work
41 1.4 S/F of Trapdoor with door & Frem. complete in all respect......... as per direction of E/I 160 SQFT
42 1.41 Iron work
43 1.42 S/F of Outdoor stand. complete in all respect......... as per direction of E/I 2 Nos
44 1.43 S/F of indoor hanging arrengement for Ducted AC. complete in all respect......... as per direction of E/I 4 Nos
45 1.44 Supply and filling of Gas charging. complete in all respect......... as per direction of E/I 15 KG
46 1.45 ikVZ&lh ds enks esa iqjkus ,0lh0 dks [kksyus ,oa LFkkiuk dk dk;ZA Part-C
47 1.46 Distmental of split AC old building to carriege new building complete in all respect with T&P&Labour......... as per direction of E/I 13 Nos
48 1.47 Installation of old split AC 1.5 tr/2.0 tr. unit Lifting, shifting, positioning & installation of indoor & outdoor unit Split AC. complete in all respect......... as per direction of E/I 13 Nos
49 1.48 Supply and fixing of Refrigerent pipe- Interconnecting refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported. complete in all respect with T&P&Labour......... as per direction of E/I (A) for 1.5 tr(12mm+6mm) 540 Rft
50 1.49 for 2.0 tr(15mm+6mm) 45 Rft
51 1.5 Electric work
52 1.51 Supply, Installation, Testing and Commissioning of control cum transmission wiring of 3 corex1.5 sq mm copper cable between indoor & outdoor units. complete in all respect with T&P&Labour......... as per direction of E/I 611 RMT
53 1.52 Supply, Installation, Testing and Commissioning of power Cable of 2 core x 4 sq mm copper cable between panel to indoor units. complete in all respect with T&P&Labour......... as per direction of E/I 1040 RMT
54 1.53 Drain pipe
55 1.54 Supply, Installation, Testing and Commissioning of drain pipe PVC hard 25mm. complete in all respect with T&P&Labour......... as per direction of E/I 130 RMT
56 1.55 Iron work
57 1.56 S/F of Outdoor stand. complete in all respect with T&P&Labour ......... as per direction of E/I 13 Nos
58 1.57 Gas charging. complete in all respect with T&P&Labour......... as per direction of E/I 13 Nos
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail