Rajasthan Rajya Vidyut Prasaran Nigam Ltd-RRVPN has published Providing And Fixing Ac In Control Room At 220 Kv Gss Aklera Jhalawar. Submission Date for this Tender is 11-06-2020. Air Conditioner Tenders in AKLERA JHALAWAR Rajasthan. Bidders can get complete Tender details and download the document.
Name of Work: Providing & Fixing AC in Control Room at 220 KV GSS Aklera.(JWR) | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | SITC of Air Cooled split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (EP foam pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 4 Mtr (IDU to ODU), R-22/R-410 Refrigerant, Remote, suitable for 400/230V +10% of 50 Hz ,1 /3 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / reciprocating / rotary compressor as specified.Hi Wall/Ceiling Wall Split\n2.0 TR with 5 star rating of BEE. Group-1\n | BI01010001010000000000000515BI0100001113 | 30 | Each |
2 | 2 | Supply, Fixing and testing of following capacity wall mounted stablisers having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp plug top making connection etc complete in all respect5 kVA. gr-1\n | BI01010001010000000000000515BI0100001114 | 30 | Each |
3 | 3 | Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC. | BI01010001010000000000000515BI0100001115 | 30 | mtr |
4 | 4 | Making hole in stone masonary/ RCC with core cutter for accomodating refrigerant pipe/ drain pipe for split/ cassattee/ ductable AC 50mm to 150mm\n | BI01010001010000000000000515BI0100001116 | 30 | Each |
5 | 5 | SITC of Interconnecting refrigerant pipe work with closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications including chase cutting, supports etc. as required.6.35 mm \n | BI01010001010000000000000515BI0100001117 | 10 | Mtr. |
6 | 6 | SITC of Interconnecting refrigerant pipe work with closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications including chase cutting, supports etc. as required.15.88 mm . Gr-1\n | BI01010001010000000000000515BI0100001118 | 10 | Mtr. |
7 | 7 | S & F of FR PVC insulated & sheathed 3 core flexible copper conductor ISI marked (IS:694) of 1.1 kV grade of following rating:4.0 Sq.mm Gr-1\n | BI01010001010000000000000515BI0100001119 | 300 | mtr |