}

Maintenance And Operation Of Sub Stns Located Inside Tech Area At Stns Under Ge ( Af ) Chabua, GE(AF) CHABUA-Assam

Military Engineer Services-MES has published Maintenance And Operation Of Sub Stns Located Inside Tech Area At Stns Under Ge ( Af ) Chabua. Submission Date for this Tender is 27-06-2020. Hand Glove Tenders in GE(AF) CHABUA Assam. Bidders can get complete Tender details and download the document.




Tender Notice

24449821
Corrigendum : Maintenance And Operation Of Sub Stns Located Inside Tech Area At Stns Under Ge ( Af ) Chabua
Open Tender
Indian
Assam
GE(AF) CHABUA
27-06-2020

Tender Details

Maintenance And Operation Of Sub Stns Located Inside Tech Area At Stns Under Ge ( Af ) Chabua , Outsourcing Of Services For Maintenance And Operation Of 11 Kv Sub Stn At Tech Flight Power House , To Operate Standby Dg Set Of 125 Kva - 01 No At Tech Flt & 62 . 5 Kva - 01 No At Mtr&S , Transformers , Lt/Amf Panels , Gods Etcfor Operating Vcbs Of Incoming , Outgoing Feeders And Including Attending Of Emergency Break Down For Operating Vcbs . Operation To Be Carried On All Working Days Including Sundays And Holidays . Contractor Shall Ensure Uninterrupted Services By Qualified/Experienced Individuals Round The Clock . The Details Of Operation Of Installations Comprising The Following Works :- ( A ) Operating Of Incoming/Outgoing Vcbs , God With Do Fuse Etc As And When Required To Maintain The Smooth Running Of Electric Supply System As Well As Safe Guard Of Man And Materials . ( B ) Operating Of Capacitor Bank Vcbs To Maintain Power Factor As Directed By Engineer-In-Charge . ( D ) In Case Of Break Down , Shut Down Or Tripping Of Vcbs , Immediate Information To Engineer- In-Charge Shall Be Conveyed . ( E ) All The Documentation Such As Log Sheets , Daily Attendance Register Shall Maintain As Per Procedure In Vogue , Outsourcing Of Services For Maintenance And Operation Of Logistic Dg Set 62 . 5 Kva In Daily Regular Basis Incl Sundays And Holidays , In Case Of Failure Of Electricity Or As Directed To Provide Un-Interrupted Power Supply , Hourly Recording Of Lt Panel Readings , Break Downs , Shut Downs And Operating Of Capacitor Bank Vcbs To Maintain Power Factor . Contractor Shall Ensure Uninterrupted Services By Qualified/Experienced Individuals For Minimum Of 8 Hours A Day As Per Schedule Decided By Engineer In Charge . , Outsourcing Of Services For Maintenance And Operation Of Base Ops Sub Station On Daily Regular Basis , Incl Sundays And Holidays To Operate Standby Dg Set Of 160 Kva - 01 No & 62 . 5 Kva - 01 No At Base Ops Power House , Lt/Amf Panels , Gods Etc And Recording Different Type Meter Readings , And Operating Of Capacitor Bank Vcbs To Maintain Power Factor . Contractor Shall Ensure Uninterrupted Services By Qualified/Experienced Individuals Round The Clock . , Outsourcing Of Services For Maintenance And Operation Of Mafi Ps-Ii , Incl Sundays And Holidays To Operate Standby Dg Set Of 160 Kva - 01 No , Vcb-06 Nos , Transformers , Lt/Amf Panels , Gods Etc And Recording Different Type Meter Readings And Operating Of Capacitor Bank Vcbs To Maintain Power Factor . Contractor Shall Ensure Uninterrupted Services By Qualified/Experienced Individuals Round The Clock . , Outsourcing Of Services For Maintenance And Operation Of Mafi Ps-I , Incl Sundays And Holidays To Operate Standby Dg Set Of 750 Kva - 02 No , Vcb-06 Nos , Transformers , Lt/Amf Panels , Gods Etc And Recording Different Type Meter Readings And Operating Of Capacitor Bank Vcbs To Maintain Power Factor . Contractor Shall Ensure Uninterrupted Services By Qualified/Experienced Individuals Round The Clock . , Outsourcing Of Services For Maintenance And Operation Of Mtrs Dg Set 62 . 5 Kva & 30 Kva Incl Sundays And Holidays , In Case Of Failure Of Electricity Or As Directed To Provide Un-Interrupted Power Supply , Hourly Recording Of Lt Panel Readings , Break Downs , Shut Downs As Directed By Engineer-In-Charge . Contractor Shall Ensure Uninterrupted Services By Qualified/Experienced Individuals For Minimum Of 8 Hours A Day As Per Schedule Decided By Engineer In Charge . , Outsourcing Of Services For Maintenance And Operation Of 102 Sqn Sub Station Incl Sundays And Holidays To Operate Dg Set Of 250 Kva - 01 No , 62 . 5/63 Kva - 02 Nos , Transformers , Lt/Amf Panels , Gods Etc In Case Of Failure Of Electricity Or As Directed To Provide Un-Interrupted Power Supply , Hourly Recording Of Lt Panel Readings , Break Downs , Shut Downs And Operating Of Capacitor Bank Vcbs To Maintain Power Factor As Directed By Engineer-In-Charge . Contractor Shall Ensure Uninterrupted Services By Qualified/Experienced Individuals Round The Clock . , Outsourcing Of Services And Operation Ams Site Sub Station For Operating Dg Set Of 750 Kva , Vcbs Of Incoming , Outgoing Feeders And Capacitor Banks To Maintain Required Power Factor Including Transformers , Lt/Amf Panels , Gods Etc In Case Of Failure Of Electricity Or As Directed To Provide Un-Interrupted Power Supply , Hourly Recording Of Lt Panel Readings , Break Downs , Shut Downs And Operating Of Capacitor Bank Vcbs To Maintain Power Factor As Directed By Engineer-In-Charge . Attending Of Emergency Break Down Round The Clock For Operating Vcbs Complete All As Specified & As Directed . Operation To Be Carried On All Working Days Including Sundays And Holidays . Contractor Shall Ensure Uninterrupted Services By Qualified/Experienced Individuals For Minimum Of 16 Hours A Day As Per Schedule Decided By Engineer In Charge . The Details Of Operation Of Installations Comprising The Following Works :- ( A ) Operating Of Incoming/Outgoing Vcbs , God With Do Fuse Etc As And When Required To Maintain The Smooth Running Of Electric Supply System As Well As Safe Guard Of Man And Materials . ( B ) Operating Of Capacitor Bank Vcbs To Maintain Power Factor As Directed By Engineer-In-Charge . ( D ) In Case Of Break Down , Shut Down Or Tripping Of Vcbs , Immediate Information To Engineer-In-Charge Shall Be Conveyed . ( E ) Operating Of Vcbs , Shut Down , Break Down Load Shading/ Unavailability Of Electric Supply Shall Be Recorded And Maintained Properly On Separate Register . ( F ) All The Documentation Such As Log Sheets , Daily Attendance Register Shall Maintain As Per Procedure In Vogue . , ( I ) Cleaning Of Sub-Station Premises ( Inside And Outside ) , Upto 6 M Of Installation Removing Debris , Grass Bushes And Vegetation Upto Required Standard Of Inspection Point Of View Daily Or As Directed By The Engineer-In-Charge Is The Contractors Whose Cost Elements Shall Deemed To Be Included In Quotated Rate Of This Item . Responsibility . ( Ii ) The Contractor Is Responsible For Switching On/Off Of Near By Street Light Switches At All Installations As Applicable Of As Directed By Engr-In-Charge . ( Iii ) The Contractor Is Responsible To Replace Burnt Out Fuse . ( Contractor Will Arrange The Fuse Wire At His Own Expense Without Any Extra Cost To The Dept ) . ( Iv ) The Contractor Is Responsible To Repair For Any Minor Internal Defect As Required All As Specified And As Directed By Engr-In-Charge . ( V ) Provision Of Protective Instruments Such As Earth Discharge Rod , Ht/Lt Hand Gloves , Suitable Capacity Of Led Torch/Focusing Light , Tools As Required For Carrying Out The Above Tasks . . Fuses , Jumpers , Grease , Petrolium Jelly , Cotton Waste Etc . As Required To Restore Supply And General Maintenance Of The Installation . However Major Item If Required During Maintenance Will Be Provided By The Department Free For Fixing Under Sch B ( Vi ) The Required Stationery , Registers , Documents Etc Will Be Supplied By The Firm For Each Installation All As Directed By The Engineer In Charge From Time To Time . ( Vii ) The Contractor Is Responsible For Providing Sweeping Materials I . E . Broom Etc All As Specified And As Directed By Engr-In-Charge . ( Viii ) Any Problems Faced In Operation Of Equipments Shall Immediately Be Intimated By The Operator To The Je E/M In Charge Of Installation And Engr-In-Charge . ( Ix ) Dhpp & Engine Oil Will Be Issued Under Sch B To Be Collected By Contractor . ( X ) Necessary Communication Instruments Shall Be Provided By The Contractor And Permission For The Same Shall Be Obtained From Af Authori

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 12-Jun-2020 Amendment Other 20-06-2020
2 17-Jun-2020 Amendment 1 Other 20-06-2020
3 20-Jun-2020 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 27-06-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 96000.0 /-
Tender Value
INR 47.90 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail