BOQ
| Name of Work:- Internal Electrification work in GRP Multypurpose Hall at Police Thana Ranipur Haridwar. | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | WGPVCPT Point wiring in PVC conduit, with piano type switch: wiring for ligh recessed PVC conduit, with piano type switch1.5 sq. mm FR PVC insulated copper conductor single core cable etc. as required. Group C | BI01010001010000000000000515BI0100001113 | 230 | No. |
| 2 | 2 | Supplying and fixing 5/6 A piano type switch on the existing switch box/ cover including connections etc. as required. | BI01010001010000000000000515BI0100001114 | 66 | No. |
| 3 | 3 | Supplying and fixing 3 pin 5/6 A socket outlet on the existing switch box/ cover including connections etc. as required. | BI01010001010000000000000515BI0100001115 | 66 | No. |
| 4 | 4 | Supplying and fixing metal box of 180 mm X 100 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 A & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. | BI01010001010000000000000515BI0100001116 | 39 | No. |
| 5 | 5 | Computer POINT- Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. | BI01010001010000000000000515BI0100001117 | 27 | No. |
| 6 | 6 | A.C. POINT- Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. | BI01010001010000000000000515BI0100001118 | 11 | No. |
| 7 | 7 | WGPVCSB Circuit/sub-man wiring in PVC conduit with the following size of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduitas required. 2 x 1.5 sq. mm + 1 x 1.5 sq mm earth wire. | BI01010001010000000000000515BI0100001119 | 672 | RM |
| 8 | 8 | WGPVCSB Circuit/sub-man wiring in PVC conduit with the following size of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduitas required. 2 x 2.5 sq. mm + 1 x 2.5 sq mm earth wire. | BI01010001010000000000000515BI0100001120 | 417 | RM |
| 9 | 9 | WGPVCSB Circuit/sub-man wiring in PVC conduit with the following size of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduitas required. 2 x 4 sq. mm + 1 x 4 sq mm earth wire. | BI01010001010000000000000515BI0100001121 | 722 | RM |
| 10 | 10 | WGPVCSB Circuit/sub-man wiring in PVC conduit with the following size of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduitas required. 2 x 6 sq. mm + 1 x 6 sq mm earth wire. | BI01010001010000000000000515BI0100001122 | 220 | RM |
| 11 | 11 | S&F of 6 to 32 amp MCB. | BI01010001010000000000000515BI0100001123 | 109 | No. |
| 12 | 12 | S&F of 63 amp F.P isolator. | BI01010001010000000000000515BI0100001124 | 9 | No. |
| 13 | 13 | S&F of 40 amp D.P isolator \". | BI01010001010000000000000515BI0100001125 | 1 | No. |
| 14 | 14 | Supplying and fixing 8 way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) | BI01010001010000000000000515BI0100001126 | 1 | No. |
| 15 | 15 | Supplying and fixing 6 way (4 + 18), Double door , horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). | BI01010001010000000000000515BI0100001127 | 1 | No. |
| 16 | 16 | Supplying and fixing 8 way (4 + 24), Double door , horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). | BI01010001010000000000000515BI0100001128 | 4 | No. |
| 17 | 17 | S&F of 6 to 16 amp Tripal Pole MCB \". | BI01010001010000000000000515BI0100001129 | 2 | No. |
| 18 | 18 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100 A, 16 kA,TPMCCB | BI01010001010000000000000515BI0100001130 | 1 | No. |
| 19 | 19 | Supplying and fixing of 4 way (4 + 12), Double door surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) | BI01010001010000000000000515BI0100001131 | 1 | No. |
| 20 | 20 | S&F of electronic type fan Regulator complete in all respects.. | BI01010001010000000000000515BI0100001132 | 66 | No. |
| 21 | 21 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. | BI01010001010000000000000515BI0100001133 | 8 | No. |
| 22 | 22 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. | BI01010001010000000000000515BI0100001134 | 70 | RM |
| 23 | 23 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. | BI01010001010000000000000515BI0100001135 | 78 | No. |
| 24 | 24 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) | BI01010001010000000000000515BI0100001136 | 264 | No. |
| 25 | 25 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. | BI01010001010000000000000515BI0100001137 | 2 | No. |
| 26 | 26 | S&F of angle holder. | BI01010001010000000000000515BI0100001138 | 73 | No. |
| 27 | 27 | Supply and laying of aluminium conductor PVC insulated cable 1100 Volts grade 70 sq. mm 3-1/2 core. | BI01010001010000000000000515BI0100001139 | 80 | RM |
| 28 | 28 | Supply and laying of aluminium conductor PVC insulated cable 1100 Volts grade 16 sq. mm 4 core. | BI01010001010000000000000515BI0100001140 | 50 | RM |
| 29 | 29 | Supply and laying of aluminium conductor PVC insulated cable 1100 Volts grade 10 sq. mm 4 core. | BI01010001010000000000000515BI0100001141 | 100 | RM |
| 30 | 30 | Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect. | BI01010001010000000000000515BI0100001142 | 60 | No. |
| 31 | 31 | Supply and fixing of recess/ Surface/ Pendent mounting round 10 to 15 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT-AA | BI01010001010000000000000515BI0100001143 | 6 | No. |
| 32 | 32 | Supply & Fixing of 20 Watt LED Surface Mounting weather proof Luminaire with PC Housing and opal finish cover confirming to IP 65 Complete in all respect | BI01010001010000000000000515BI0100001144 | 2 | No. |
| 33 | 33 | Supply and fixing of 16 SWG M.S. drum with luvers duly painted including making hole in the wall for exhaust fan and finishing properly complete in all respect. | BI01010001010000000000000515BI0100001145 | 12 | No. |
| 34 | 34 | S&F of 63 A. 415 V Heavy Duty Double Break HRC fuse type metal clad TPN complete with HRC fuse etc. on angle ironframe complete in all respect. | BI01010001010000000000000515BI0100001146 | 1 | No. |
| 35 | 35 | supply and fixing of ceiling fan of heavy duty 1400mm approved make of Havells/Orient/Bajaj/khaitan complete in all respects. | BI01010001010000000000000515BI0100001147 | 66 | No. |
| 36 | 36 | supply and fixing of Exhaust fan of heavy duty 230mm approved make of Havells/Orient/Bajaj/khaitan Complete in all respects. | BI01010001010000000000000515BI0100001148 | 12 | No. |
| 37 | 37 | Supply and fixing of fire extinguisher, ABC Type 4.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. | BI01010001010000000000000515BI0100001149 | 9 | No. |
| 38 | 38 | Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. | BI01010001010000000000000515BI0100001150 | 4 | No. |
| 39 | 39 | Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. | BI01010001010000000000000515BI0100001151 | 8 | No. |
| 40 | 40 | Supply and fixing of C02 type fire extinguisher 6.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. | BI01010001010000000000000515BI0100001152 | 4 | No. |
| 41 | 41 | Supply and fixing of fire bucket, round bottom made of G.I. sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-Charge. | BI01010001010000000000000515BI0100001153 | 12 | No. |
| 42 | 42 | Supply & Erracetion of factory fabricated & wired\nmetal clad dust and vermin proof floor mounting,\nM.S. Channel Base with bottom and top cable\nentreis Electrical control panel with TPN MCCB's\n(Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber\netc.complete in all respects. The instrument chamber\nshall be separate and shall comprise of flush type\ndigital metering system for phase to phase voltage\nand single phase voltage, current and other\nparameters(KVA,P.F,KW etc) in each phase with\ntouch type selector switches for different readings,\ninstrument fuses, current transformer etc. The panel\nboard shall have suitable capacity electrolytic\nalumininum busbars as per IS8623 or above\nistulated with heat shrink sleeving and mounted on\nnon hygroscopic supports such as CMC/BMC\nsupport with deteachable side covers and shall be\nsuitable for extension on the sides. The MCCB's\nshall be complete with suitable cable end boxes,\ncompression glands and indicating lamp on\nincoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of\n100 Amp and above shall have an Ammeter. The\npanel board shall be fabricated with CRCA sheet\nwith a minimum thickness of 1.6mm/2mm. Cubicle\ntype switch board shall be of cat A & B Only. Incoming- 200 Amp. MCCB-1 N. Out going- 100 Amp. MCCB-1 No & 63 Amp. MCCB-3 Nos. | BI01010001010000000000000515BI0100001154 | 1 | No. |
| 43 | 43 | S&F of 200 AMP four pole Mouled case type on load change over switch with enclosure including the cost of labour, T & P and material reuired for proper completion of the work as per direction and satisfaction of Engineer an charge. | BI01010001010000000000000515BI0100001155 | 1 | No. |
| 44 | 44 | Supply and erection of 200 Amp. TPN Rising Mains complete with top end cover plate etc. On angle iron wall brackets complete in all respect. | BI01010001010000000000000515BI0100001156 | 2 | No. |
| 45 | 45 | Supply & fixing of 10 mtr GI Octagonal Pole of approved make (top dia 100 mm, Bottom dia 200 mm and base plate 16mm thick) having 3 mm thikness with Double arm bracket/ring bracket (for maounting 4 nos flood light) 1 Mtr length in 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling and Required T&P completee in all respect. | BI01010001010000000000000515BI0100001157 | 2 | No. |
| 46 | 46 | Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 70 to 90 Watt. Confirming to IP 65 protection complete in all respect. CAT(AAA) | BI01010001010000000000000515BI0100001158 | 8 | No. |
AI Tender Summary
Tender Timeline
May 29, 2020
11:30 IST
Tender Published
Tender notice published.
CompletedJun 14, 2020
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJun 16, 2020
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender