| 1 | 1 | M&L for taking down high pressure SV/ MV/ MH /FTL/LED street light fitting and Flood Light fittings of any wattage / any height of pole/ walls/ any location for repairs or replacement of burnt out the accessories and rectifying the fault complete all as specified and directed by Engineer-in-Charge.\nNote: - LED Drivers, Surge protection and cable shall be measured separately under relevant items of this schedule\n | | 239 | Each |
|---|
| 2 | 2 | Fixing only street light fittings/flood lights after repairs of the any wattage on poles/walls, any height comprising of LED Drivers ,Surge protection with cables suitable for mounting on 40 mm /25 mm GI pipe or bracket arms with pole fixing attachments and other connected accessories duly prewired complete with copper conductor for electrical connections and testing complete all as specified and directed. | | 85 | Each |
|---|
| 3 | 3 | S&F LED street light fitting pressure die cast aluminium housing with heat resistant toughened glass & IP 65 protection luminaries of capacity 30 Watt complete all as specified and directed by Engineer-in-Charge.\nMake:- Crompton Cat part no LSTS-30-CDL OR equivalent make Bajaj/Surya etc. | | 86 | Each |
|---|
| 4 | 4 | All as per item No.03 above but 45 Watt complete.\nMake:- Crompton Cat part no LSTP-45-CDL OR equivalent make Bajaj/Surya etc. | | 50 | Each |
|---|
| 5 | 5 | S&F LED Flood light fitting pressure die cast aluminium housing with heat resistant toughened glass & IP 66 protection luminaries of capacity 80 Watt complete all as specified and directed.\nMake:- Surya Cat part no.SLE FL 80W IP66 LUMOS MAX OR equivalent make Bajaj/Crompton etc. | | 10 | Each |
|---|
| 6 | 6 | All as per item No.05 above but 120 Watt complete.\nMake:- Surya Cat part no.SLE FL 120W IP66 LUMOS MAX OR equivalent make Bajaj/Crompton etc | | 8 | Each |
|---|
| 7 | 7 | S&F 5 KV surge for LED street light, 230 volts, 50 HZ compatible for industrial & outdoor LED Fixtures up to rated power of 75 W for fixing in repairs completeall as specified and directed.\nMake : Crompton /Surya/Bajaj | | 20 | Each |
|---|
| 8 | 8 | S&F 5 KV surge for LED street light, 230 volts, 50 HZ compatible for industrial & outdoor LED Fixtures rated power above 75 W & up to 150W for fixing in repairs completall as specified and directed.\nMake : Crompton /Surya/Bajaj | | 15 | Each |
|---|
| 9 | 9 | S&F Drivers for LED street lights 25W/30W, 230 Volts, 50 HZ complete all as specified and directed\nMake : Crompton /Surya/Bajaj | | 15 | Each |
|---|
| 10 | 10 | S&F Drivers for LED street lights 45W/60W, 230 Volts, 50 HZ completeall as specified and directed\nMake : Crompton /Surya/Bajaj | | 15 | Each |
|---|
| 11 | 11 | S&F Drivers for LED Flood lights 100W/120W, 230 Volts, 50 HZ complete all as specified and directed\nMake : Crompton /Surya/Bajaj | | 6 | Each |
|---|
| 12 | 12 | S&F 1100 Volts heavy duty round sheathed multistranded three core bright annealed bare copper conductor cable of size 2.5 Sqmm for electrical connections to the street lights fittings including taking out old cable completeall as specified and directed\nMake:- Polycab/Finolex/Gloster/Havells\n | | 50 | RM |
|---|
| 13 | 13 | S&F 1100 Volts heavy duty round sheathed multistranded three core bright annealed bare copper conductor cable of size 4 Sqmm for electrical connections to the street lights fittings including taking out old cable complete all as specified and directed\nMake:- Polycab/Finolex/Gloster/Havells\n | | 50 | RM |
|---|
| 14 | 14 | M&L for painting the swaged steel tubural LT poles including cross arms,clamps and light bracktes surface of any discription after preparation of old painted surface(removing old paint by paint removers and cleaning with scraper any number of exiting coats) with one finishing coat aluminium paint and marking pole no. as per exiting numbers and painting of lower portion of pole in alternate layer of black and yellow shades/colour completeall as specified and directed.\nMake:- BERGER (LUXOL)/ ASIAN (APCOLITE)/ SHALIMAR (SUPERLAC) | | 110 | Each\njob |
|---|
| 15 | 15 | M&L for painting the swaged steel tubural HT poles including cross arms,clamps and light bracktes surface of any discription after preparation of old painted surface(removing old paint by paint removers and cleaning with scraper any number of exiting coats) with one finishing coat aluminium paint and marking pole no. as per exiting numbers and painting of lower portion of pole in alternate layer of black and yellow shades/colour complete all as specified and directed.\nMake:- BERGER (LUXOL)/ ASIAN (APCOLITE)/ SHALIMAR (SUPERLAC) | | 12 | Each\njob |
|---|
| 16 | 16 | supply and fixing GI bracket fixing suitable for street light fitting made out of 40mm dia GI tubing of light grade bent to shape of 1.5m length complete including taking out old one complete all as specified and directed. | | 20 | Each |
|---|
| 17 | 17 | Taking down old XLPE LT Underground Cable complete all as specified and directed by Engineer-in-Charge. \nNote:- Earth work will be measured and paid separately under respective items. | | 700 | RM |
|---|
| 18 | 18 | Supply and Laying LT underground cable XLPE insulated and sheathed armoured cable 1100 volts 2 core 10 Sqmm aluminium conductor in trenches/poles and connecting with all accessories complete all as specified and directed by Engineer-in-Charge. | | 150 | RM |
|---|
| 19 | 19 | All as per item No. 18 above but of cable 4 core 16 Sqmm complete all as specified and directed by Engineer-in-Charge. | | 200 | RM |
|---|
| 20 | 20 | All as per item No.18 above but of cable 3.5 core 25 Sqmm complete all as specified and directed by Engineer-in-Charge. | | 250 | RM |
|---|
| 21 | 21 | All as per item No.18 above but of cable 3.5 core 35 Sqmm complete all as specified and directed by Engineer-in-Charge. \n | | 100 | RM |
|---|
| 22 | 22 | Supply only lugs for UG cable for 3.5/4 core 16Sqmm to 70Sqmm complete all as directed by Engineer-in-Charge. | | 50 | Each job |
|---|
| 23 | 23 | Excavation in trenches not exeeading 1.5m wide and not exceeding 1.5m depth/width and getting out loose/soft soil for laying of under ground cable all as specified and directed by Engineer - in - Charge. | | 120 | CUM |
|---|
| 24 | 24 | Excavation in trenches exc 1.5m in width and exc 1.5m in depth/width and getting out loose/soft soil for laying of under ground cable all as specified and directed by Engineer - in - Charge. | | 1 | CUM |
|---|
| 25 | 25 | Returning/ filling including spreading, levelling and well ramming in layers not exc 25cm in thick complete all as specified and directed by Engineer-in-Charge. | | 68 | CUM |
|---|
| 26 | 26 | Removal of surplus soil to a distance not exc 50m away and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge. | | 52 | CUM |
|---|
| 27 | 27 | Supply and spread sand in cable trenches and providing cushioning for the cable complete all as specified and directed by Engineer-in-Charge.\nNote:- Only punned thickness of 18cm will be measured for the purpose of payment.\n | | 36 | CUM |
|---|
| 28 | 28 | Supply and lay burnt brick of size 230x115x75mm for protection of cable, laying in trenches complete all as directed by Engineer-in-Charge. | | 4 | per 1000Nos |
|---|
| 29 | 29 | S&F GI tubing of 50mm dia light grade at road cross for protection cable as per site requirement and sealing the pipe both ends with sealing compound complete including taking down old one completeall as specified and directed\nMake :- TATA/ Zindal/Zeenith\n | | 20 | RM |
|---|
| 30 | 30 | All as per item No.29 above but 40mm dia complete\nMake :- TATA/ Zindal/Zeenith\n | | 20 | RM |
|---|
| 31 | 31 | S&F of pin type, porcelain vitreous while brown of green insulator including one Galvanised mild steel spindle two galvanised iron washers and one Galvanised iron nut 100mm Height 65 mm dia for 1100 Volts complete including taking down old unserviceable insulator complete all as specified and directed | | 15 | Each |
|---|
| 32 | 32 | S&F of shackle type insulator porcelain virtuous white, brown or green 75mm Height 90mm dia for 1100 volts grade including one Galvanized mild steel straps washers insulator bolts washers and nuts complete including taking down old unserviceable insulator complete all as specified and directed | | 10 | Each |
|---|
| 33 | 33 | M & L for restringing of LT over head ACSR conductor form pin, disc, shackle insulators with suitable binding wire to insulators and connecting in 4 conductor system position complete all as specified and directed by Engineer-in-Charge.\nNote:- 4 run of ACSR conductor will be measured as one length. | | 2000 | RM |
|---|
| 34 | 34 | M/L for PVC line separator suitable for 4 wire LT O/H lines at any height complete all as specified and directed by Engineer-in-Charge. | | 40 | Each |
|---|
| 35 | 35 | M/L for PVC line separator suitable for 2 wire LT O/H lines at any height complete all as specified and directed by Engineer-in-Charge. | | 25 | Each |
|---|
| 36 | 36 | S&F HOT moulded (FRP) jucntion box for street light pole with locking arrangementt with IP -65 protection of size 280 x 200 with 32 Amp 4 way heavy duty terminal block with 10 Amps MCB SP and two steel bracket to fix with pole complete all as specified and directed by Engineer-in-Charge. Make-Hansel/Sintex | | 20 | Each |
|---|
| 37 | 37 | S&F Steel tubular swaged poles complete with cast iron base plate, finial taperplug, bolts, nuts and screws as specified type 410 SP-31 (9 Metre long) including cross arms, clamps etc complete and applying two coats of aluminium paint and plainting to band/strip with two coats of synthetic enamel paint including numbering of poles at a height of 1.5 mtr above ground level as per existing having 15mm width and 50mm bold letter completeall as specified and directed | | 5 | Each |
|---|
| 38 | 38 | All as per item No.37 above but 410 SP-37 ( 9.5 Metre long) complete . | | 4 | Each |
|---|
| 39 | 39 | M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregates as in foundation complete all as specified and directed | | 2 | Cum |
|---|
| 40 | 40 | M&L for PCC 1:2:4 type B 2 using 20mm graded stone aggregates as in coping etc completeall as specified and directed. | | 1 | Cum |
|---|
| 41 | 41 | M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including taking down of old one complete all as specified and directed | | 2.5 | Per Qtl |
|---|
| 42 | 42 | M&L for triming of tree branches (touching HT/LT OH line)uptto 10cm girth at any height carefully taking shutdown including suitable disposal of cut of tree branches as in repair completeall as specified and directed\nNote:- tools & plants including safety measures equipments like belt,ladder & rops etc shall be arranged by the contractor at own cost. | | 30 | Each\nTree |
|---|
| 43 | 43 | Cutting vegetation and surface dressing not exceeding 15 cm deep including removing the materials to a distance not-exc 60 mtr complete. (Note :- Item shall be executed twice in each installation and quantity is given for two operation. However unit rate to be quoted by the tendered for single operation only) | | 2000 | Sqr Mtr |
|---|
| 44 | 44 | S&F on load change over switch 4 pole, 415v, 50Hz in sheet steel enclosure of capacity 63 Amps completeall as specified and directed | | 2 | Each |
|---|
| 45 | 45 | S&F for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and directed. | | 5 | Each |
|---|