Essential Repairs Renewal To H T Cts 22 Kv Indoor Outdoor Breakers Ht Mocv S Vcb Rmus And Repair Maintenance Of Transformer Dehydration Filtration Of Transfomer Oil And Other Misc Wk At Naval Station Akaranja, CWE KARANJA-Maharashtra

Military Engineer Services-MES has published Essential Repairs Renewal To H T Cts 22 Kv Indoor Outdoor Breakers Ht Mocv S Vcb Rmus And Repair Maintenance Of Transformer Dehydration Filtration Of Transfomer Oil And Other Misc Wk At Naval Station Akaranja. Submission Date for this Tender is 15-06-2020. Circuit Breakers Tenders in CWE KARANJA Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

24429588
Essential Repairs Renewal To H T Cts 22 Kv Indoor Outdoor Breakers Ht Mocv S Vcb Rmus And Repair Maintenance Of Transformer Dehydration Filtration Of Transfomer Oil And Other Misc Wk At Naval Station Akaranja
National Competitive Bid
Indian
Maharashtra
CWE KARANJA
15-06-2020

Tender Details

Essential Repairs Renewal To H T Cts 22 Kv Indoor Outdoor Breakers Ht Mocv S Vcb Rmus And Repair Maintenance Of Transformer Dehydration Filtration Of Transfomer Oil And Other Misc Wk At Naval Station Akaranja

Key Value

Document Fees
INR 500 /-
EMD
INR 60000.0 /-
Tender Value
INR 3 Lakhs /-

BOQ Items

NAME OF WORK: Essential repairs/renewal to HT CT's 22 Kv , indoor/ outdoor breakers, HT MOCB's, VCB, RMUs and repair/maintenance of transformer, Dehydration/ filtration of transformer oil and other Misc wks at Naval Station Karanja
Sl. No. Description of Item of Work Item Code / Make Quantity Unit
1 1 Periodical Check / preventive maint/Painting work for HT MOCB 22 KV 800 Amps, 50 Hz 700 MVA yearly as under :-\n(a) Checking the closing & opening operation of MOCB and functional checks and Repair/ Replacement of the defective components.\n\n\n\n\n\n\n\n BI01010001010000000000000515BI0100001113 3 Each Job Per Breaker
2 1.01 (b) Overhauling and Calibration of relays artificial load for primary/secondary injection in unit setup subject item (After completion of work calibration and cordination the test report duly sign by Engineer-in-Charge and contractor to be capt on records.) BI01010001010000000000000515BI0100001114
3 1.02 (c) Setting and coordination of relays will be carried out as per sote reqmt and as directed by Engr-in -charge. BI01010001010000000000000515BI0100001115
4 1.03 (d) Checking and recording of IR value of MOCB trolley and panel. BI01010001010000000000000515BI0100001116
5 1.04 (e) Checking/repairing/rectification of the control wiring. BI01010001010000000000000515BI0100001117
6 1.05 (f) Replacement of panel heater 80 watt. BI01010001010000000000000515BI0100001118
7 1.06 (g) Replacement of worn out bushing PT/Busbar support insulators BI01010001010000000000000515BI0100001119
8 1.07 (h) Replacement of unserviceable and Open circuit CT's. BI01010001010000000000000515BI0100001120
9 1.08 (j) Checking the fibre plates and secondary and primary bushing/ terminals its gaskets and PTs - 03 Nos , 22KV/110V burnt to be replaced, testing of dielectric strength of transformer oil and its PTs, below 33 KV same to be replaced. Note: Transformer oil req of PT will be measured and paid under relevent items schedule 'A' as supply only. BI01010001010000000000000515BI0100001121
10 1.09 (k) Checking the fibre plates and secondary and primary bushing/ terminals its gaskets and CTs - 03 Nos , 22KV/110V burnt to be replaced, testing of dielectric strength of transformer oil and its CTs, below 33 KV same to be replaced. Note: Transformer oil req of CT will be measured and paid under relevent items schedule 'A' as supply only. BI01010001010000000000000515BI0100001122
11 1.1 (l) High voltage testing with high voltage tester of CTs - 03 Nos & Breaker pole - 03 Nos, PTs - 03 Nos to withstand working pressure of HT 22 KV to ascertain servicieability and spare parts found defective to be replaced for smooth functioning as directed. (The test report of high voltage testing to be duly signed by contractor and Engineer-in-Charge) BI01010001010000000000000515BI0100001123
12 1.11 (m) Labour only for Opening the busbar chamber of HT 22KV MOCB panel board cleaning the bus bar chamber, inspect the CT's wiring, spout insulator & bus-bar joints & tightening if required & heating up with hot air blower to remove moisture, meggering, HV testing applying TRTPPEX(B) supplied against Sl Item No 4(b) here-in-after to bus bar & commissioning complete all as specified & directed by Engineer-in-charge. BI01010001010000000000000515BI0100001124
13 1.12 Note:- (i) All spares required for replacement shall be measured and paid separately under respective item of schedule here-in-after as supply only. BI01010001010000000000000515BI0100001125
14 1.13 (ii) Machine grease, oil, liquid sealant and any minor item costing upto Rs 250 will be included in the unit rate of above item and for satisfactory function of the breakers and no extra cost will be allowed. Decision of accepting officer in this regard will remain final & binding. BI01010001010000000000000515BI0100001126
15 1.14 (iii) The overhauling of HT breakers to be carried out either through OEM's service Engineer/authorised dealer those who posses HT handling license. BI01010001010000000000000515BI0100001127
16 2 Periodical Check/preventing maint / Painting of HT VCB/RMUs Panel of Make:ABB/ Arriva/ C&G / Schineder etc 630 Amps/800 Amp Rating Indoor and outdoor type detailed as under :- BI01010001010000000000000515BI0100001128 7 Each Job Per Breaker
17 2.01 (a) Servicing (i.e light primary terminals) & repair/replacement of defective components. BI01010001010000000000000515BI0100001129
18 2.02 (b) Functional checks. BI01010001010000000000000515BI0100001130
19 2.03 (c) Mechanisum servicing and lubrication. BI01010001010000000000000515BI0100001131
20 2.04 (d) Protection checks BI01010001010000000000000515BI0100001132
21 2.05 (e) Control wiring tightness. BI01010001010000000000000515BI0100001133
22 2.06 (f) Power connection tightness. BI01010001010000000000000515BI0100001134
23 2.07 (g) Insulation measurement of main circuit. BI01010001010000000000000515BI0100001135
24 2.08 (h) Contact resistance of main circuit. BI01010001010000000000000515BI0100001136
25 2.09 (j) Checking the operation of VCB/RMUs panel BI01010001010000000000000515BI0100001137
26 2.1 (k) Overhauling and Calibration of relays 2 OC + 1E by injection artificial load on each multiple setting of relays and test report their of duly signed by Engineer-in-Charge and contractor kept of record. The artificial load and necceary equipment shell be arranged by the contractor without any extra cost. BI01010001010000000000000515BI0100001138
27 2.11 (l) Setting and coordination of relays. BI01010001010000000000000515BI0100001139
28 2.12 (m) Checking and recording of IR value of breaker trolley. BI01010001010000000000000515BI0100001140
29 2.13 (n) Checking/repairing/rectification of the control wiring. BI01010001010000000000000515BI0100001141
30 2.14 (o) Checking the panel heater and replacement of faulty space heater BI01010001010000000000000515BI0100001142
31 2.15 (p) Replacement of the unserviceable / open circuit CT's. BI01010001010000000000000515BI0100001143
32 2.16 (q) Testing of PT, PT circuits, IR test and high voltage withstand test and if any part from effictive to be replaced by the contractor without any extra cost. BI01010001010000000000000515BI0100001144
33 2.17 (r) Cleaning the breaker externally and internally thoroughly with lint free cloth, complete all as specified & directed by Engineer-in-Charge. \n BI01010001010000000000000515BI0100001145
34 2.18 Note:- (i) All spares required for replacement shall be measured and paid separately under respective items of schedule 'A' here-in-after as supply only. BI01010001010000000000000515BI0100001146
35 2.19 (ii) The overhauling of HT breakers to be carried out either through OEM's service Engineer/authorised dealer those who posses HT handling license. BI01010001010000000000000515BI0100001147
36 3 Supply only following spare parts required for item No.1.00 here-in-bofore (Note:- the element of fixing of spare is already included in respective Sl Item No. 1 here-in-before) suitable for MOCB of 800 Amps, 700 MVA all as per sample :- BI01010001010000000000000515BI0100001148
37 3.01 (a) Spout insulator (Epoxy) BI01010001010000000000000515BI0100001149 2 Each
38 3.02 (b) TRTPPX (B) for HT 22 KV for breaker BI01010001010000000000000515BI0100001150 2 Each
39 3.03 (c) Current Transformer 22 KV single phase indoor Resin cast CT Ratio 30-15/5-5 Amps Class 1.0 insulation level 28 KV/75 KV as per IS 2075 BI01010001010000000000000515BI0100001151 3 Each
40 3.04 (d) OLTF assembly suitable for MOCB, 22KV, 800Amps, indoor type all as specified and directed. BI01010001010000000000000515BI0100001152 2 Each
41 3.05 (e) Strip type heater 80 watt BI01010001010000000000000515BI0100001153 2 Each
42 3.06 (f) Closing coil BI01010001010000000000000515BI0100001154 2 Each
43 3.07 (g) Tripping coil BI01010001010000000000000515BI0100001155 2 Each
44 3.08 (h) Control fuse 2 Amps with HRC fuse and fuse holder in existing panel and as specified and directed. Make:EE/Standard/Havells/L&T BI01010001010000000000000515BI0100001156 4 Each
45 3.09 (j) Insulation Tape suitable for HT 22 KV 1.5" wide. \nMake : 3M or equivalent. BI01010001010000000000000515BI0100001157 10 RM
46 3.1 (k) MOCB oil tank gasket suitable for MOCB 22KV 800 Amps indoor type all as specified and directed. BI01010001010000000000000515BI0100001158 2 Each
47 3.11 (l) Baffle pot assembly suitable for MOCB, 22 KV, 800 Amps, indoor type all as specified and directed. BI01010001010000000000000515BI0100001159 3 Each
48 3.12 (m) Main moving contact bolted/threaded type suiatable for MOCB, 22KV, 800Amps, indoor type all as specified and directed. BI01010001010000000000000515BI0100001160 3 Each
49 3.13 (n) HT bushing with spindle BI01010001010000000000000515BI0100001161 2 Each
50 3.14 (o) Thermostat - 0-100 Deg. Celcius BI01010001010000000000000515BI0100001162 3 Each
51 3.15 (p) Moving contact rod BI01010001010000000000000515BI0100001163 3 Each
52 3.16 (q) Upper fix contact BI01010001010000000000000515BI0100001164 2 Each
53 3.17 (r) Lower fix contact BI01010001010000000000000515BI0100001165 3 Each
54 3.18 (s) Top and bottom male contact BI01010001010000000000000515BI0100001166 3 Each
55 3.19 (t) Female contact BI01010001010000000000000515BI0100001167 3 Each
56 3.2 (u) Support insulator BI01010001010000000000000515BI0100001168 2 Each
57 3.21 (v) Partition fiber plate BI01010001010000000000000515BI0100001169 3 Each
58 4 Supply only following spare parts required Sl for item No. 2.00 here-in-before.\n (Note:- the element of fixing of spares is already included in respective Sl Item No. 2 here-in-before) for HT VCB/RMUs panel 630 Amp/800 Amp 22 KV,: BI01010001010000000000000515BI0100001170
59 4.01 O/C & Earth fault relay with IDMT and inst charatrostics MC 61 A Make : L&T 30 Volt DC complete all as specified and as directed. BI01010001010000000000000515BI0100001171 3 Each
60 4.02 Master Trip relay 30v DC 3 NO + 1 NC Make:- Ashida, complete all as specified and as directed. BI01010001010000000000000515BI0100001172 3 Each
61 4.03 Digital voltmeter (KV meter) 0 to 30 V (PTR 22 KV/110 V , AC with selector switch complete all as specified and as directed. BI01010001010000000000000515BI0100001173 5 Each
62 4.04 Digital Amps meter class - 1.0, CTR ratio - 0 to 200/100-5-5A complete all as specified and as directed. BI01010001010000000000000515BI0100001174 5 Each
63 4.05 Numerical O/C & E/F Relay 1/5A (miccom P 111) Make : Areva, complete all as specified and as directed. BI01010001010000000000000515BI0100001175 3 Each
64 4.06 Supervison relay 924 volt DC, VAX31248071BM Model complete all as specified and as directed. BI01010001010000000000000515BI0100001176 3 Each
65 4.07 ANNC 12 W facia Annunciator relay complete all as specified and as directed. BI01010001010000000000000515BI0100001177 3 Each
66 4.08 Breaker control switch 25 A non lockable Make: Kaycee complete all as specified and directed BI01010001010000000000000515BI0100001178 7 Each
67 4.09 Local remote switch lockable Make: Kaycee complete all as specified and directed. BI01010001010000000000000515BI0100001179 6 Each
68 4.1 TNC switch Make: Kaycee complete all as specified and directed BI01010001010000000000000515BI0100001180 7 Each
69 4.11 Space Heater 100 watt Make: Eltec complete all as specified and directed BI01010001010000000000000515BI0100001181 7 Each
70 4.12 Thermostate 30 to 100 Degree, Make: Girish complete all as specified and directed BI01010001010000000000000515BI0100001182 6 Each
71 4.13 MCB 2 pole 10 A - 16 A, complete all as specified and directed. Make: Legrand / Havells / Schnider/ BI01010001010000000000000515BI0100001183 8 Each
72 4.14 Limit Switch 1 NO+ 1 NC , 15 A 240 Volt , Make; Brisk complete all as specified and directed BI01010001010000000000000515BI0100001184 25 Each
73 4.15 22 KV HT insulator ressin cast for busbar support complete all as specified and directed BI01010001010000000000000515BI0100001185 8 Each
74 4.16 22 KV HT , PT Fuse 15 Amp Primerry complete all as specified and directed BI01010001010000000000000515BI0100001186 8 Each
75 4.17 HT insulation tape 3m Make complete all as specified and directed BI01010001010000000000000515BI0100001187 30 RM
76 4.18 22 KV HT slive, Make: 3m, Reycem complete all as specified and directed BI01010001010000000000000515BI0100001188 15 RM
77 4.19 Indicator Lamp LED type Red, Yellow, Green, Blue, White, Amber, Clear complete all as specified and directed BI01010001010000000000000515BI0100001189 25 Each
78 4.2 Current transformer terminal (CATD) Make: connectwell/Elmex complete all as specified and directed BI01010001010000000000000515BI0100001190 7 Each
79 4.21 AC & DC Terminal (CST/CST10) 65 A, 750 Volt ,Make: Connectwell/Elmex complete all as specified and dircted BI01010001010000000000000515BI0100001191 7 Each
80 4.22 Control Terminal (CST/CST 2.5) 36 A, 750 Volt, Make: Connectwell/Elmex complete all as specified and directed BI01010001010000000000000515BI0100001192 20 Each
81 5 Dismantling top cover alongwith conservator tank for filteration of Transformer oil and after draining out transformer oil up to terminal level in situ by disconnecting LT/HT cable copper busbar of earthing strips,replacement of LT/HT bushing and terminal rod of brass gasket, nuts, bolts & washers etc. Refitting top cover & conservator tank after cleaning and filteration, removing the sludge , reconnecting HT/LT cable/conductor and earthing strips,& filteration of tranformer oil including toping up of transformer oil by adding new transformer oil having 60 KV dielectric strength and charging/testing the transformer on load complete all as directed by Engineer-in-charge,for transformer of rating upto 160 KVA capacity. BI01010001010000000000000515BI0100001193 3 Each Job
82 5.01 Note : (i) Contractor should make his own arragement of filteration plant at each transformer sites for filteration of transformer oil including provision of electric supply to the filteration plant. BI01010001010000000000000515BI0100001194
83 5.02 (ii) New transformer oil shall be measured and paid separately. BI01010001010000000000000515BI0100001195
84 5.03 (iii) Cost of HT/LT bushing and terminal rod wiil be measured and paid separately . BI01010001010000000000000515BI0100001196
85 5.04 (iv) Filteration of oil will be measured separately. BI01010001010000000000000515BI0100001197
86 6 Ditto - all as per srl item No.5.00 above, but for transformer of rating 200 KVA. BI01010001010000000000000515BI0100001198 2 Each Job
87 7 Ditto - all as per srl item No.5.00 above, but for transformer of rating 250 KVA. BI01010001010000000000000515BI0100001199 2 Each Job
88 8 Ditto - all as per srl item No.5.00 above but for transformer of rating 315 KVA. BI01010001010000000000000515BI0100001200 3 Each Job
89 9 Ditto - all as per srl item No.5.00 above but for transformer of rating 400 KVA. BI01010001010000000000000515BI0100001201 2 Each Job
90 10 Ditto - all as per srl item No.5.00 above but for transformer of rating 500 KVA. BI01010001010000000000000515BI0100001202 2 Each Job
91 11 Ditto - all as per srl item No.5.00 above but for transformer of rating 630 KVA. BI01010001010000000000000515BI0100001203 1 Each Job
92 12 Ditto - all as per srl item No. 5.00 above but for transformer of rating 1000 KVA. BI01010001010000000000000515BI0100001204 1 Each Job
93 13 Supply only the following spare parts of transfomer 22 /0.433 KV operated in item no 5.00 To 12.00 : BI01010001010000000000000515BI0100001205
94 13.01 a) HV Bushings BI01010001010000000000000515BI0100001206
95 13.02 i) 22 KV from up to 160 KVA BI01010001010000000000000515BI0100001207 3 Each
96 13.03 ii) 22 KV from 200 KVA to 630 KVA BI01010001010000000000000515BI0100001208 3 Each
97 13.04 iii) 22 KV 1000 KVA BI01010001010000000000000515BI0100001209 1 Each
98 13.05 b )HV terminal rod with nut bolts, caps etc BI01010001010000000000000515BI0100001210
99 13.06 i) 22 KV from up to 160 KVA BI01010001010000000000000515BI0100001211 3 Each
100 13.07 ii) 22 KV from 200 KVA to 630 KVA BI01010001010000000000000515BI0100001212 2 Each
101 13.08 iii) 22 KV 1000 KVA BI01010001010000000000000515BI0100001213 1 Each
102 13.09 c) LV Bushings BI01010001010000000000000515BI0100001214
103 13.1 i) 22 KV from up to 160 KVA BI01010001010000000000000515BI0100001215 2 Each
104 13.11 ii) 22 KV from 200 KVA to 630 KVA BI01010001010000000000000515BI0100001216 3 Each
105 13.12 iii) 22 KV 1000 KVA BI01010001010000000000000515BI0100001217 1 Each
106 13.13 d ) LV terminal rod with nut bolts, caps etc BI01010001010000000000000515BI0100001218
107 13.14 i) 22 KV from up to 160 KVA BI01010001010000000000000515BI0100001219 2 Each
108 13.15 ii) 22 KV from 200 KVA to 630 KVA BI01010001010000000000000515BI0100001220 3 Each
109 13.16 iii) 22 KV 1000 KVA BI01010001010000000000000515BI0100001221 1 Each
110 13.17 e ) LT Brass connectors BI01010001010000000000000515BI0100001222
111 13.18 i) 12 mm BI01010001010000000000000515BI0100001223 2 Each
112 13.19 ii) 20 mm BI01010001010000000000000515BI0100001224 3 Each
113 13.2 iii) 30 mm BI01010001010000000000000515BI0100001225 3 Each
114 13.21 iv) 42 mm BI01010001010000000000000515BI0100001226 2 Each
115 14 Supply and filling new transformer oil having 60 KV di-electric strength and conforming to IS for replacement or topping up to oil level mark at the conservator. Make ;- Savita chemical / HPCL BI01010001010000000000000515BI0100001227 2500 Ltr
116 15 Filteration of transformer oil, in situ, to achieve dielectric strength of the oil not less than 50 KV all as directed by Engineer-in-charge.Contractor will submit before & after testing report of transformer oil. BI01010001010000000000000515BI0100001228 16000 Ltr
117 15.01 Note :(i)Contractor will submit before & after testing report of transformer oil. BI01010001010000000000000515BI0100001229
118 16 Disconnecting HT/LT and earth termination connections from transformer, taking down the transformers from plinth/platform and loading into the vehicle; transporting the same to workshop for carrying out necessary repairs and back ,reconnecting HT/LT connections at site and charging the transformer on load, commissioning and testing including meggar test at site all as directed by Engineer - in - Charge BI01010001010000000000000515BI0100001230 1 Each Job
119 17 Material for rewinding of transformer core with same numbers/grade of copper enamelled conductor with same size of turns as per manufactures's specification and testing and commissioning transformers after repair. BI01010001010000000000000515BI0100001231 250 Kg
120 18 Material for reinsulation of copper windings (LT and HT), Class B, with Electrical Grade Insulating Kraft paper all confirming to IEC-60554-3-5 (1984). BI01010001010000000000000515BI0100001232 40 Kg
121 19 Draining out transformer oil, dismantling top cover alongwith conservator tank, taking out core assembly after disconnecting connections, rewinding with same size and type of copper conductor and number of turns and insulating material such as paper insulator sleeves, heating etc. Putting back the core assembly into the tank after removing sludge and replacement of HT & LT bushing complete with brass terminal, refixing top cover and conservator including replacement of gasket, nut, bolts & washers (filling new transformer oil having 60 KV dielectric strength and carring out type tests as per IS 2026 in presence of Engineer - in - charge for the following capacity :- BI01010001010000000000000515BI0100001233
122 19.01 a) 75 to 160 KVA BI01010001010000000000000515BI0100001234 1 Each Job
123 19.02 b) 200 to 315 KVA BI01010001010000000000000515BI0100001235 1 Each Job
124 19.03 c) 400 to 1000 KVA BI01010001010000000000000515BI0100001236 1 Each Job
125 19.04 Note for item No 16 to 19 : BI01010001010000000000000515BI0100001237
126 19.05 (i) New transformer oil and its filling shall be measured and paid separately under relevant items of schedule. BI01010001010000000000000515BI0100001238
127 19.06 (ii) Cost of rewinding material, insulation material and spares of transformer shall be measured and paid separately under relevant item of Sch . BI01010001010000000000000515BI0100001239
128 19.07 (iii) Replacement of spares will be on required basis all as directed by Engr-inCharge. BI01010001010000000000000515BI0100001240
129 19.08 (iv) The loading, unloading & transportation of Transformer upto authorised workshop & back at site after repiar and installation is deemed to be included in unit rates of above item. BI01010001010000000000000515BI0100001241
130 19.09 (v) The rewinding of Transformer to be carried out at authorised workshop & after completion routine testing to be carried out as per IS in presence of officer detailed by accepting officer & test report there of ro be kept on record. BI01010001010000000000000515BI0100001242
131 20 Disconnecting HT/ LT and earth termination connections from Trolley Mounted Transformer (500 KVA Cap.) and towing the same to a location, within 5 KMs, as directed by Engr-in-Charge including M&L for making of HT/ LT and earth termination connections of the Trolley Mounted Transformer to the existing electric distribution system in Indoor/Outdoor Substation complete all as specified and directed by Engr-in-Charge. BI01010001010000000000000515BI0100001243 1 Each Job
132 20.01 NOTE - BI01010001010000000000000515BI0100001244
133 20.02 (a). Trolley Mounted transformer will be issued to contractor by MES however Contractor has to make his own arrangements of towing vehicle. BI01010001010000000000000515BI0100001245
134 20.03 (b). The job also includes disconnecting of HT/ LT and earth termination connections of Trolley Mounted Transformer and towing the same to a location as directed by Engr-in-Charge. BI01010001010000000000000515BI0100001246
135 20.04 Testing of transformers of various capcities installed at various locations at Naval Station Karanja by performing following tests -\n1.IR Value on L.V & H.V side using 500 V & 5KV Megger respectively.\n2.Ratio on all the taps.\n3.Magnetic Balance tests on L.V & H.V.\n4.Vector group.\n5.Magnetizing current.\n6.Winding Resistance Test on H.V & LV terminals. BI01010001010000000000000515BI0100001247 23 Each
136 20.05 Note : (i) Contractor should make his own arragement of testing equipments and electric supply so required BI01010001010000000000000515BI0100001248
137 20.06 (ii) A detailed Test Report should be submitted to Engr-in-Charge. BI01010001010000000000000515BI0100001249
138 21 Excavation in trenches for not exc 1.5 mtr wide and not exc 1.5 mtr depth and getting out in soft/loose soil including taking out faulty cable/cable, cable covers and GI pipe complete all as specified and directed. BI01010001010000000000000515BI0100001250 13.5 Cum
139 22 Returning filling in including spreading levelling watering and well ramming in layers n.exc 25cm complete all as specified & directed. BI01010001010000000000000515BI0100001251 7.965 Cum
140 23 Removing excavated materials n.exc 50m and depositing where directed at a level n.exc 1.5m above the Starting point. BI01010001010000000000000515BI0100001252 5.535 Cum
141 24 M & L for dry river sand as sand cushioning for protection of UG cable including punning of sand in layers all as specified. BI01010001010000000000000515BI0100001253 2.025 Cum
142 25 Supply & laying un-reinforced precast concret cable cover class LV type 1, flat size 250mm x 150mm x 40 mm all as specified & directed. BI01010001010000000000000515BI0100001254 180 Each
143 26 Supply & fixing, jointing, connecting & testing in trenches XLPE/PVC insulated PVC sheathed cable heavy duty 1100 volts grade, aluminum conductor in trenches / ducts of following sizes including taking out cable cover & cable all as specified and directed : BI01010001010000000000000515BI0100001255
144 26.01 a)3.5 Core x 300 Sqmm BI01010001010000000000000515BI0100001256 50 RM
145 26.02 b )3.5 Core x 400 Sqmm BI01010001010000000000000515BI0100001257 50 RM
146 27 Supply and fix in repairs 1.1 KV straight through joint kit 3.5 core 150 sq mm to 185 sqmm of make 3M/M Seal/ Raychem. BI01010001010000000000000515BI0100001258 2 Each
147 28 Supply and fix in repairs 1.1 KV straight through joint kit 3.5 core 240 sq mm to 300 sqmm of make 3M/M Seal/ Raychem. BI01010001010000000000000515BI0100001259 2 Each
148 29 Supply and fix in repairs 1.1 KV straight through joint kit 3.5 core 400 sq mm of make 3M/M Seal/ Raychem. BI01010001010000000000000515BI0100001260 2 Each
149 30 S&F in repairs heat shirnk right angled boots for XLPE 22 KV 120 Sqmm cable including dismantling of HT cable from HT side of Transformer / HT Breakers. BI01010001010000000000000515BI0100001261 3 Each set
150 31 M&L for Heat shrinkable cable end termination joint including jointing Kit outdoor type suitable for earthed 3 core 95/120 sqmm HT 22KV XLPE aluminium conductor cable and HV test after jointing and connecting up complete all as specified and directed. Make:- Raychem/ XICON/ M-Seal/Denson BI01010001010000000000000515BI0100001262 3 Each
151 32 M & L for Heat Shrinkable straight through jointing kit with all necessary jointing material suitable for HT 22 KV XLPE 3 core 95/120 sqmm aluminium conductor cable complete all as specified and directed. Make- Raychem/ XICON/ M-Seal/Denson BI01010001010000000000000515BI0100001263 3 Each
152 33 S & F in repairs breather assembly with silica gel suitable in situ for transformer of any rating as directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001264 20 Each
153 34 S & F in repairs Dial type temprature guage 100mm dia with dual calibration in degree celcius and degree Fahrenheit, range 0 to 100 c and equivalent degree Fahrenheit complete with capabillary tube and sensor suitable for transformer of any rating as directed by Engineer-in-Charge BI01010001010000000000000515BI0100001265 4 Each
154 35 M&L for replacement of self-indicating Orange to Green Silica Gel granules from transformer breather assembly. BI01010001010000000000000515BI0100001266 5 KG
155 36 M & L for preparation of old painted surfaces of 100 KVA transformer with scrapers, any number of coats, any width or girth and applying two coats of synthetic enamel paint by spray painted including writing 5mm/MES numbers complete all as specified and directed BI01010001010000000000000515BI0100001267 3 Each Job
156 37 -Ditto- all as per item No 36.00 above but 160 KVA transformer. BI01010001010000000000000515BI0100001268 5 Each Job
157 38 -Ditto- all as per item No 36.00 above but 200/250 KVA transformer BI01010001010000000000000515BI0100001269 5 Each Job
158 39 -Ditto- all as per item No 36.00 above but 315 KVA transformer BI01010001010000000000000515BI0100001270 5 Each Job
159 40 -Ditto- all as per item No 37 above but 400/500 KVA transformer BI01010001010000000000000515BI0100001271 4 Each Job
160 41 -Ditto- all as per item No 36.0 above but 630 KVA transformer BI01010001010000000000000515BI0100001272 2 Each Job
161 42 -Ditto- all as per item No 36.0 above but 1000 KVA transformer BI01010001010000000000000515BI0100001273 1 Each Job
162 43 S&F in repairs end termination box HV side with cover made of 3mm thick MS sheets including fibre board insulation sheets & including nut bolts and washer including painting of steel surfaces with two coats of red oxide zinc chorme primer all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001274 3 Each
163 44 -Ditto- all as per item No 43.0 above, but for LV side. BI01010001010000000000000515BI0100001275 3 Each
164 45 M&L for earthing complete with GI earth plate electrode of size 60cm x 60cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below the normal ground level connected with GI strip 32 x 6mm by means of bolts, nuts, check nuts & washers of galvanished iron steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50m, with and including PCC chamber in PCC (1:2:4), type B1,using (20mm graded stone aggregate),"mild steel angle iron frame" made out of MS angle iron of size 40x40x6mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 40mm dia medium grade pipe for watering 40mm dia light grade, GI pipe for lead protection in and including alternate layers of charcoal dust and common salt complete all as shown in electrical "plate No '3' and connected to earthing test point all as specified and indicated including testing on completion including retrieving old GI earth plate, CI cover, GI pipes, angle iron frame from existing earthing complete all as specified and directed. BI01010001010000000000000515BI0100001276 9 Each
165 46 S&F earth continuity conductor or main earthing lead fixed to wall on batten or fixed to pole GI strip 32 x 6 mm all as specified and directed. BI01010001010000000000000515BI0100001277 20 RM