Military Engineer Services-MES has published Repair Maint Of Various Type Of Fans Summer Appliances And Gysers In Married Otm Accn In The Area Of Cod Me Line 505 Abw 17 Sikh Li 226 Asc Esd Fol Depot Atc Map Narayana Map Fafa Accn Kabul Line Officer Md Accn Kirby Place Map Kirby Plac. Submission Date for this Tender is 16-06-2020. Air Conditioner Tenders in GE (N) DELHI CANTT-10 Delhi. Bidders can get complete Tender details and download the document.
Name of Work: REPAIR/MAINT OF VARIOUS TYPE OF FANS/SUMMER APPLIANCES AND GYSERS IN MARRIED/OTM ACCN IN THE AREA OF COD, ME LINE, 505 ABW, 17 SIKH LI, 226 ASC, ESD, FOL DEPOT, ATC, MAP NARAYANA, MAP (FAFA) ACCN KABUL LINE, OFFICER MD ACCN KIRBY PLACE , MAP KIRBY PLACE, STN ROAD, MOUD ROAD, AIRPORT ROAD, OFFICE COMPLEX UNDER GE (N) DELHI CANTT-10. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Taking down ceiling fan of any sweep by unscrewing nut/bolts from its position and fixing the same to its original place after necessary cleaning, oiling, greasing, replacement of defective parts bush, bearing, condenser, flexible wire, down rod, canopies, painting and re-winding all as specified and directed. (Note : Rubber bush, bearing, capacitor, copper flexible wire, down rods, canopies, winding and paintng are measured and paid separately as supply only rates and fixing charges for spare parts shall deemed to be included) | 1450 | Each | |
2 | 2 | Rewinding of burnt winding of stater of the ceiling fan 1200 mm sweep with matching gauge and turns of super enamelled copper wire leathenic paper, glass sleeves etc including varnishing,heating the windings as per manufacturer design and reassembling the same complete testing all as specified and as directed. | 560 | Each | |
3 | 3 | All as per above but for 1400 mm Sweep | 650 | Each | |
4 | 4 | Painting of ceiling fan of any sweep complete with one coat of 1st grade quality synthetic enamel paint by spraying including preparation of old painted surfaces to remove any type of sticky dust, oil marks etc and filling cavities with fillers and writing letters and numbers complete all as specified and as directed. | 710 | Each | |
5 | 5 | Taking down Exhaust/Ventilation fan of any sweep by unscrewing nut/bolts from its position (high rise bldgs up to 8 storey height) and fixing the same to its original place after necessary cleaning, oiling, greasing, replacement of defective parts bush, bearing, condenser,flexible connection wire,louvers,shutters,painting and re-winding all as specified and directed. (Note : Rubber Bush, Gun Metal Bush, bearing, capacitor, twin core twisted copper flexible wire, Louvers,shutters, winding and paintng are measured and paid separately as supply only rates and fixing charges for spare parts shall deemed to be included) | 350 | Each | |
6 | 6 | Rewinding of burnt winding of the Exhaust fan up to 300 mm dia with matching gauge and turns of superenamelled copper wire leathenic paper, glass sleeves etc including varnishing,heating the windings as per manufacturer design and reassembling the same complete testing all as specified and as directed. | 130 | Each | |
7 | 7 | All as per above but 380/450mm Sweep | 110 | Each | |
8 | 8 | All as per above but 600 mm Sweep | 80 | Each | |
9 | 9 | All as per above item but ventilation fan up to 200mm Sweep. | 125 | Each | |
10 | 10 | Painting of exhaust fan of any sweep complete with one coat of 1st grade quality synthetic enamel paint by spraying including preparation of old painted surfaces to remove any type of sticky dust, oil marks etc and filling cavities with fillers and writing letters and numbers complete | 150 | Each | |
11 | 11 | Taking down pedestal/wall mounted fan of any sweep by unscrewing nut/bolts from its position and fixing the same to its original place after necessary cleaning, oiling, greasing, replacement of defective parts bush, bearing, condenser,flexible connection wire and re-winding all as specified and directed. (Note : Bush, bearing,capacitor, twin core twisted copper flexible wire and winding are measured and paid separately as supply only rates and fixing charges for spare parts shall deemed to be included) | 55 | Each | |
12 | 12 | Rewinding of burnt winding from the stater of the pedestal/wall mounted fan any sweep with matching gauge and turns of superenamelled copper wire leathenic paper, glass sleeves etc including varnishing,heating the windings as per manufacturer design and reassembling the same complete testing all as specified and as directed. | 30 | Each | |
13 | 13 | Supply only for ball bearing number of 6201 to 6204 as required for fan complete (Make : SKF/NBC) | 1650 | Each | |
14 | 14 | Supply only rubber bush for shackle with bolt, nut and lock pin suitable for ceiling fan | 650 | Each | |
15 | 15 | Supply only twin twisted copper flexible wire of size 1.0 sqmm | 270 | RM | |
16 | 16 | Supply only capacitor 2.5 Mfd, 240 Volts (Make- Tibcon/Havells/Epcos/Asian) | 1750 | Each | |
17 | 17 | All as per above but 3.15 Mfd | 350 | Each | |
18 | 18 | All as per above but 4.0 Mfd | 55 | Each | |
19 | 19 | Supply only PVC canopy for ceiling fan | 65 | Set of 2 | |
20 | 20 | Supply only down rod for ceiling fan of 1' long, colour match with existing fan complete all as directed | 75 | Each | |
21 | 21 | All as per above but 2' long | 60 | Each | |
22 | 22 | S&F in replacement Fan Hook made out of MS Flat Iron of size 50x6mm of required shape at site incl nut, bolt and washer for fixing of C/fan complete all as directed | 50 | Each | |
23 | 23 | M&L for GI tubing 40 mm bore (medium grade) for fixing of ceiling fans and make good the disturbed wall surface and all as specified and directed. | 35 | RM | |
24 | 24 | M&L for ceiling fan blade suitable for 1200mm sweep complete | 35 | Set | |
25 | 25 | All as per above but for 1400mm sweep | 45 | Set | |
26 | 26 | S&F in replacement louvers with shutter metallic body suitable for exhaust fan upto 450mm sweep with necessary fixing accessories after taking down existing all as specified and directed. (Note : Louver Shutter are to be replaced up to high rise bldg/8 storey including all necessary T&P and fixing arrangement by the contractor) | 55 | Each | |
27 | 27 | S&F in replacement louver with shutter plastic body suitable for ventilation fan upto 250 mm sweep with necessary fixing accessories after taking down existing all as specified and directed. (Note : Louver Shutter are to be replaced up to high rise bldg/8 storey including all necessary T&P and fixing arrangement by the contractor) | 110 | Each | |
28 | 28 | M&L for exhaust fan blade (metal body) suitable for 300/380/450/600 mm sweep for exhaust fan complete all as directed (Make as per sample) | 45 | Each set | |
29 | 29 | M&L in replacement ventilation fan blade (PVC type) suitable for 200/250mm sweep complete (Make as per sample) | 25 | Each set | |
30 | 30 | All as per above but for 300mm sweep | 15 | Each set | |
31 | 31 | M&L in repair for electronic fan regulator flush type, 5 stepped type complete all as directed | 25 | Each | |
32 | 32 | M&L in repair for modular fan regulator, 5 stepped type complete all as directed | 10 | Each | |
33 | 33 | Supply and fixing in repair of High speed ceiling fan in white colour 1400mm sweep 220-240 volt with one set of 3 blades, down rod, hanger clamp PVC conopy complete and UNSV ceiling fan depositing in E/M store yard. (Make Crompton Greaves/Usha/Havells) | 10 | Each | |
34 | 34 | Supply and fixing in repair of 300mm dia, 900 RPM, exhaust fan, heavy duty with louver shutter, frame, blades complete and unsv Ex fan depositing in E/M store yard all as directed (Make: Khaitan/Crompton Greaves/Havells) | 5 | Each | |
35 | 35 | All as per above item but 380mm sweep | 5 | Each | |
36 | 36 | All as per above item but 450mm sweep | 5 | Each | |
37 | 37 | Supply and fixing in repair of 400mm sweep, wall mounting fan, oscalating type complete and UNSV fan deposit in E/M store yard complete all as directed (Make: Khaitan/Crompton Greaves/Havells) | 3 | Each | |
38 | 38 | Supply and fixing in repair of 200/225/250mm dia, 900 RPM, fresh air fan woth plastic louvers incl frame complete and UNSV fan depositing in E/M store yard all as directed (Make: Bajaj/Crompton Greaves/Havells) | 10 | Each | |
39 | 39 | Taking down carefully electric geyser of any type and capacity by disconnecting electric and water supply connection, opening nut, bolt, washer and replacing the defective parts and reassembling after cleaning and replacing defective parts and re-installing the same in original position and making necessary electric and water supply connection and testing complete all as specified and directed. (Note: Spare items shall be measured and paid seperately as supply only under relevant items) | 225 | Each Job | |
40 | 40 | Supply only geyser inner water tank 35/50Ltrs capacity steel body as per sample ,duly tested complete all as specified and directed. | 10 | Each | |
41 | 41 | All as per above item but 25 Ltrs capacity | 15 | Each | |
42 | 42 | Supply only of Heating element capacity 1.5 KW (Round/Triangular) ISI marked suitable for geyser (as per sample) complete all as specified and directed.Make : as per sample | 250 | Each | |
43 | 43 | All as per above item but capacity 2 KW. | 250 | Each | |
44 | 44 | Supply only thermostat suitable for 50/35/25 ltrs capacity geysers (Make :- as per sample) | 110 | Each | |
45 | 45 | Supply only Heavy duty hot water connection, SS rope threaded type with brass unions at both ends, 45cm long 15mm bore complete. | 225 | Each | |
46 | 46 | Supply only cold water connection, PVC connection with brass unions at both ends, 45cm long 15mm bore complete. | 170 | Each | |
47 | 47 | Supply only replacement of safety valve/Pressure release valve for geysers of any capacity/ type | 25 | Each | |
48 | 48 | Supply only indicator lamp Red/Green suitable for geyser of any type/capacity (Make as per sample) | 125 | Each | |
49 | 49 | Supply only geyser base plate assembly of any capacity any model all as specified and directed complete (Make as per sample) | 55 | Each | |
50 | 50 | Supply only geyser top and bottom cover any capacity any model all as specified and directed complete (Make as per sample) | 25 | Each | |
51 | 51 | S&F in replacement of glass wool heat resistance type of exist type (8 kgs) for 25 to 50 ltrs capacity geysers complete | 20 | Each | |
52 | 52 | S&F in replacement of outer cover MS sheet/ABS body of geysers 25 to 50 Ltrs capacity complete | 20 | Each | |
53 | 53 | M&L soldering/brazing inner geyser tanks 50/25 liters with brass solder and refixing after testing the leakage complete incl replacement of rubber packaging ring heat resistance type all as specified directed complete. | 5 | Job | |
54 | 54 | Material & Labour for spray painting 25 to 50 Ltrs capacity with two coats of white synthetic enamel paint (1st quality approved brand ) after preparation of surface all as specified and directed complete. | 45 | Each | |
55 | 55 | M&L in replacement of Plug top, 3 pin, 05 amps, 230 volt | 30 | Each | |
56 | 56 | M&L in replacement of Plug top, 3 pin, 15 amps, 230 volt | 30 | Each | |
57 | 57 | S&F in repair PVC insulated and sheathed flexible cable 3 core Multi-stranded copper conductor size 2.5 Sqmm 1100 volt grade after taking out old unserviceable one including electric connection complete all as specified and directed. (Make : FINOLEX/POLYCAB/PLAZA) | 200 | RM | |
58 | 58 | Supply and fixing in repair of desert/Air cooler of body size 25"x25"x32", made out of corrosion resistant, 18 SWG GI sheet duly powder coated paint with 500mm sweep copper wound fan motor kit 180 watt with metallic blade, ISI marked, 1400 RPM, 230 volt AC, tank capacity not less than 100 ltr, incl plastic submersible pumps, electronis fan regulator with P/switch, desert cooler to be fitted with 6mm thick plywood to cover the gap as required size at existing window and old unsv desert cooler depositing in E/M Store yard complete all as directed (Make : JK Classic/Decool/Supreme/Kapsun) | 2 | Each | |
59 | 59 | S&F in replacement fan motor kit incl blade, steel body for desert cooler of flow capacity upto 4000 Cum/Hr complete all as directed (Make :- Khaitan/CG/Bajaj)\n | 6 | Each | |
60 | 60 | M&L fan blade (PVC type) suitable for desert cooler up to 450mm sweep fan complete all as directed (Make as per sample) | 5 | Each set | |
61 | 61 | S&F in repair plastic submersible pump suitable for desert cooler any size complete all as directed (Make : Khaitan/CG/Bajaj\n | 5 | Each | |
62 | 62 | Supply and fixing 6mm thick plywood sheet (ISI marked) waterproof fixed in window including cutting as desired size for passing air of desert cooler. | 8 | Sqm | |
63 | 63 | S&F desert cooler pad (set of three) made out of wood wool etc suitable for desert cooler of any size. | 15 | Each | |
64 | 64 | S&F in replacement desert coolers body of required size made out of 18 SWG MS sheet complete including inside panel made out of 22 SWG MS sheet complete and grill duly painted with two coat synthetic enameled paint over one coat of red oxide inside complete all as directed. | 10 | Each Job | |
65 | 65 | S&F in repair PVC flexible pipe of high density for 15 mm bore for desert cooler of any size complete | 40 | RM | |
66 | 66 | M&L for servicing of any type and any make of split type AC/Window AC of 2 ton/1.5 ton capacity complete by dismantaling of AC and re-fixing after cleaning and replacement defective parts, dismantling the cover of condensing unit carefully and carry out servicing cleaning of the external surface (both side) throughly with the help of descaling chemical, brush, plain water and dry properly by using air blower for cleaning air dust deposited on epqt and charging of gas in adequate quantity as required re-fixing after repair complete\n | 10 | Each | |
67 | 67 | Supply and charging of refrigerant gas R-134a/R-22 for any type and capacity of Window/Split AC and checking for leakage (if any) after charging of gas complete | 10 | Kg | |
68 | 68 | S&F in replacement Motor double shaft 1/5 HP capacity for window type AC 1.5 ton/2 ton capacity complete (Make : As per sample) | 3 | Each | |
69 | 69 | S&F in replacement Motor single shaft 1/5 HP capacity for split type AC 1.5/2.0 ton capacity complete (Make : As per sample) | 3 | Each | |
70 | 70 | S&F in repair thermostat for split AC/Window AC of capacity 1.5/2 Ton complete (Make : As per sample) | 3 | Each | |
71 | 71 | S&F of filter for split AC of 1.5/2 TR cap including taking out the old u/s filter complete | 2 | Each | |
72 | 72 | S&F of Reverse valve (heating and cooling type) suitable for split AC of capacity 1.5 TR by taking out of old u/s valve from the outdoor unit of AC and fixing of new valve by breazing/soldering and charging of adequate quantity of gas and testing on completion complete all as directed \n | 2 | Each | |
73 | 73 | All as per above but for split AC of 2.0 TR capacity | 1 | Each | |
74 | 74 | S&F in replacement hermetically sealed rotary type compressor unit of capacity 1.5 TR and charging of adequate quantity of refrigerant gas and testing on completion complete (Make : Bule Star/Carrier/Kirloskar/Emarsion/Teckmesh) | 2 | Each | |
75 | 75 | All as per above but for 2.0 TR capacity | 1 | Each | |
76 | 76 | S&F in repair Power Circuit Board (PCB) suitable for split type AC of capacity 1.5TR / 2.0 TR complete | 2 | Each | |
77 | 77 | Taking down carefully point wiring of any type complete with fittings & fixtures such as ceiling rose, switches, sockets, wooden batten, conduit etc. including accessories including making good disturbed surface to match the existing surface all as specified & directed | 362 | Each Point | |
78 | 78 | M&L for Point wiring with PVC insulated, PVC unsheathed FRLS cable, single core, multi-stranded, copper conductor cable 1.5 Sqmm size,1100 V grade, drawn into and including PVC casing capping not less then 20mm wide, ISI marked, with 1.5 Sqmm unsheathed, stranded copper cable for continuous earth wire and including pressed MS sunk in box 1.6 mm thick, concealed in wall, covered with with 3 mm thick plastic laminated bakalite sheet, ISI marked all as specified & directed for the folowing :- | |||
79 | 79 | (a) One ceiling/exhaust fan point controlled by one switch | 100 | Each Point | |
80 | 80 | (b) One point for socket outlet 5 amp on independent board | 25 | Each Point | |
81 | 81 | (c) One point for socket outlet 5 amp same board | 10 | Each Point | |
82 | 82 | (d) One 3 pin 15 Amp socket outlet point controlled by one switch using 2.5 sqmm copper conductor cable with continuous earth wire of 1.5 sqmm copper conductor on independent board | 15 | Each Point | |
83 | 83 | M&L for Point wiring with PVC insulated, PVC unsheathed FRLS, single core, multi-stranded copper conductor cable 1.5 Sqmm size, 1100V grade, drawn into and including PVC rigid conduit medium grade (ISI marked) not less than 20mm dia, concealed conduit wiring including cutting chases in wall and making good disturbed surface to match the existing surface with and including PVC unsheathed cable single core copper conductor 1.5 Sqmm as continuous earth wire and including pressed MS sheet sunk in box 1.6 mm thick with 3 mm thick laminated bakelite sheet all as specified for :- | |||
84 | 84 | (a) One ceiling/exhaust fan point controlled by one switch | 150 | Each Point | |
85 | 85 | (b) One point for socket outlet 5 amp on independent board | 30 | Each Point | |
86 | 86 | (c) One point for socket outlet 5 amp same board | 12 | Each Point | |
87 | 87 | (d) One 3 pin 15 Amp socket outlet point controlled by one switch using 2.5 sqmm copper conductor cable with continuous earth wire of 1.0 sqmm copper conductor on independent board | 20 | Each Point | |
88 | 88 | S&F ceiling rose surface type bakelite 65x50mm three terminal complete | 250 | Each | |
89 | 89 | S&F switch piano flush type, 6 amps, 230V AC,single pole, one way | 327 | Each | |
90 | 90 | S&F switch piano flush type 16 amps, 230V AC single pole one way | 35 | Each | |
91 | 91 | S&F socket out let multipurpose suitable for 2 pin and 3 pin 6 amp flush type | 77 | Each | |
92 | 92 | S&F socket out let multipurpose type, for 3 pin 6 and 16 amp flush type. | 35 | Each | |
93 | 93 | M&L in replacement for two single core (submain) PVC insulated cable with 4 sqmm nominal cross sectional area stranded copper conductor and one single core green PVC insulated 2.5 sqmm stranded copper conductor earth continuity cable drawn through non metallic rigid PVC conduit 20 mm dia concealed in wall including all conduit and fixing accessories complete | 300 | RM | |
94 | 94 | S&F in replacement pressed sheet metal enclosure (MCB DB), single phase and neutral with 200 Amps rated bus bar, double door type, 240 volts, DB to be grouted on wall including disturbed surface to match existing surface complete all as specified & directed for the following no. of way :- | |||
95 | 95 | (a) 4 way | 4 | Each | |
96 | 96 | (b) 8 way | 8 | Each | |
97 | 97 | S&F in repair MCB SP, 10-32 amps, 240 volts, 'C' series, 10 KA breaking capacity complete | 69 | Each | |
98 | 98 | S&F in repair MCB SPN 63 amp, 240 volts, 'C' series, 10 KA breaking capacity & connection complete | 12 | Each | |
99 | 99 | S & F in repair sheet metal enclosure with Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB with 20 Amps complete | 20 | Each | |
100 | 100 | S & F in repair industrial type two pin and earth plug top complete | 20 | Each | |
101 | 101 | M&L in repair PVC casing caping of size 20 x 12mm, ISI marked, incl accessories, screw etc complete all as directed | 200 | RM | |
102 | 102 | SCHEDULE OF CREDIT REFER SRL PAGE NO 91 RS 71388.50 |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail