Educational and Research Institute Government Departments Closing in 0 days TDR #24417071

Purchase Of Different Types Of Lab Kits

Issued by Government Departments · AIIMS, New Delhi, Delhi
Tender Value
Ref. Documents
Estimated cost
Bid Submission
29 Jun 2020
0 days left
EMD
1 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
AIIMS, New Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Purchase Of Different Types Of Lab Kits-2 Rheumatoid Factor (RF) By Latex Agglutination n• Kit should have both positive and negative control along with other reagent for Latex agglutination test n• Price should be quoted for per unit test which should be inclusive of positive and negative control and GST. n 3 Anti Nuclear Antibody (ANA) by Indirect Immunofluorescent (IIF). n• Kit should have microwells with Hep 2010 cell mounted on Biochip having high proportion of mitotic cells as well as biochip with primate liver as additional substrate for parallel detection and confirmation. n• Kit should have both positive and negative controls. n• Test system should be free from need of humidity chamber. n• Price should be quoted for per unit test which should be inclusive of positive and negative control and GST. n n 4 Anti LKM 1 by (ELISA) n• Test system should have highly purified antigen (LKM.1—Cytochrome P 450 IID6) coated on microwells. n• Test system should have positive control, negative control and not more than three standard/caliberators. n• Test should have high sensitivity and specificity. n• Total incubation time should be less than 80 minutes. n• Test should be compatible with all ELISA readers. n• Price should be quoted for per unit test which should be inclusive of positive control, negative control, caliberator/standard and GST. n 5 nAnti Neutrophil Cytoplasmic Antibody (ANCA) by Indirect Immunofluorescent (IIF) n• Each microwell should have biochip containing Ethanol fixed granulocyte, Formalin fixed granulocyte and Hep2 cells for better and reliable interpretation. n• Each kit should have positive control for P-ANCA and C-ANCA as well as negative control. n• Test system should be free from need of humidity chamber. n• Price should be quoted for per unit test which should be inclusive of positive and negative control and GST. n 6 Anti-ds DNA by ELISA n• Test system should give quantitative result in (IU/ml). n• Test system should have positive control, negative control, and not more than three standard /caliberators. n• Test should have high sensitivity and specificity. n• Total incubation time should be less than 80 minutes. n• Test should be compatible with all ELISA readers. n• Price should be quoted for per unit test which should be inclusive of positive control, negative control, caliberator/standard and GST. n n 7 Anti Cardiolipin ELISA (IgG, IgM) by ELISA n• Test system should be give quantitative values in PL/ml as per Antiphospholipid Standardisation Laboratory (USA). n• Test system should have positive control, negative control, and not more than three standard/caliberators. n• Test should have high sensitivity and specificity. n• Total incubation time should be less than 80 minutes. n• Test should be compatible with all ELISA readers. n• Price should be quoted for per unit test which should be inclusive of positive control, negative control, caliberator/standard and GST. n 8 Anti Smooth Muscle Antibody (ASMA) by Indirect immunofluorescent (IIF) n• Each microwell should contain rat stomach. n• Kit should have positive and negative controls. n• Test system should be free from need of humidity chamber. n• Price should be quoted for per unit test which should be inclusive of positive control, negative control, caliberator/standard and GST. n 9 Rheumatoid Factor (RF) By Nephelometer. n• Kit should have both positive and negative control. n• Kit should be compatible with all Nephelometers. n• Price should be quoted for per unit test which should be inclusive of positive control, negative control and buffer (if needed for the test) and GST. n n 10 PR3 – ANCA (IgG) by (ELISA) n• Test system should have highly purified microwells coated with mixture of native PR3 and recombinant PR3. n• Test system should have positive control, negative control and not more than three standard/caliberators. n• Test should have high sensitivity higher than 90% and specificity more than 95%. n• Total incubation time should be less than 90 minutes. n• Test should be compatible with all ELISA readers. n• Price should be quoted for per unit test which should be inclusive of positive control, negative control, caliberator/standard and GST. n n n 11 MPO-ANCA (IgG) by (ELISA) n• Test system should have highly purified antigen coated on microwells. n• Test system should have positive control, negative control and not more than three standard/calibrators. n• Test should have high sensitivity higher than 90% and specificity more than 95%. n• Total incubation time should be less than 90 minutes. n• Test should be compatible with all ELISA readers. n• Price should be quoted for per unit test which should be inclusive of positive control, negative control, calibrators/standard and GST. n n 12 Mosaic for ANA, ASMA & AMA by Indirect Immunofluorescent (IIF) n• Each microwell should have separate biochips coated with rat stomach, rat kidney, Rat liver and Hep2 cells. n• Kit should have positive control for ANA, ASMA and AMA. n• Test system should be free from need of humidity chamber. n• Price should be quoted for per unit test which should be inclusive of positive control, negative control, caliberator/standard and GST. n n

BOQ

Name of Work: Purchase of Lab Kits on Two years Rate Contract basis
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Purchse of Lab Kits
21.01Rheumatoid Factor (RF) By Latex Agglutination\n• Kit should have both positive and negative control along with other reagent for Latex agglutination test\n• Price should be quoted for per unit test which should be inclusive of positive and negative control and GST.\nitem11per Unit
31.02Anti Nuclear Antibody (ANA) by Indirect Immunofluorescent (IIF).\n• Kit should have microwells with Hep 2010 cell mounted on Biochip having high proportion of mitotic cells as well as biochip with primate liver as additional substrate for parallel detection and confirmation.\n• Kit should have both positive and negative controls.\n• Test system should be free from need of humidity chamber.\n• Price should be quoted for per unit test which should be inclusive of positive and negative control and GST.\n\nitem21per Unit
41.03Anti LKM 1 by (ELISA)\n• Test system should have highly purified antigen (LKM.1—Cytochrome P 450 IID6) coated on microwells.\n• Test system should have positive control, negative control and not more than three standard/caliberators.\n• Test should have high sensitivity and specificity.\n• Total incubation time should be less than 80 minutes.\n• Test should be compatible with all ELISA readers.\n• Price should be quoted for per unit test which should be inclusive of positive control, negative control, caliberator/standard and GST.\nitem31per Unit
51.04\nAnti Neutrophil Cytoplasmic Antibody (ANCA) by Indirect Immunofluorescent (IIF)\n• Each microwell should have biochip containing Ethanol fixed granulocyte, Formalin fixed granulocyte and Hep2 cells for better and reliable interpretation.\n• Each kit should have positive control for P-ANCA and C-ANCA as well as negative control.\n• Test system should be free from need of humidity chamber.\n• Price should be quoted for per unit test which should be inclusive of positive and negative control and GST.\nitem41per Unit
61.05Anti-ds DNA by ELISA\n• Test system should give quantitative result in (IU/ml).\n• Test system should have positive control, negative control, and not more than three standard /caliberators.\n• Test should have high sensitivity and specificity.\n• Total incubation time should be less than 80 minutes.\n• Test should be compatible with all ELISA readers.\n• Price should be quoted for per unit test which should be inclusive of positive control, negative control, caliberator/standard and GST.\n\nitem51per Unit
71.06Anti Cardiolipin ELISA (IgG, IgM) by ELISA\n• Test system should be give quantitative values in PL/ml as per Antiphospholipid Standardisation Laboratory (USA).\n• Test system should have positive control, negative control, and not more than three standard/caliberators.\n• Test should have high sensitivity and specificity.\n• Total incubation time should be less than 80 minutes.\n• Test should be compatible with all ELISA readers.\n• Price should be quoted for per unit test which should be inclusive of positive control, negative control, caliberator/standard and GST.\nitem61per Unit
81.07Anti Smooth Muscle Antibody (ASMA) by Indirect immunofluorescent (IIF)\n• Each microwell should contain rat stomach. \n• Kit should have positive and negative controls.\n• Test system should be free from need of humidity chamber.\n• Price should be quoted for per unit test which should be inclusive of positive control, negative control, caliberator/standard and GST.\nitem71per Unit
91.08Rheumatoid Factor (RF) By Nephelometer.\n• Kit should have both positive and negative control.\n• Kit should be compatible with all Nephelometers.\n• Price should be quoted for per unit test which should be inclusive of positive control, negative control and buffer (if needed for the test) and GST.\n\nitem81per Unit
101.09PR3 – ANCA (IgG) by (ELISA)\n• Test system should have highly purified microwells coated with mixture of native PR3 and recombinant PR3.\n• Test system should have positive control, negative control and not more than three standard/caliberators.\n• Test should have high sensitivity higher than 90% and specificity more than 95%.\n• Total incubation time should be less than 90 minutes.\n• Test should be compatible with all ELISA readers.\n• Price should be quoted for per unit test which should be inclusive of positive control, negative control, caliberator/standard and GST.\n\n\nitem91per Unit
111.1MPO-ANCA (IgG) by (ELISA)\n• Test system should have highly purified antigen coated on microwells.\n• Test system should have positive control, negative control and not more than three standard/calibrators.\n• Test should have high sensitivity higher than 90% and specificity more than 95%.\n• Total incubation time should be less than 90 minutes.\n• Test should be compatible with all ELISA readers.\n• Price should be quoted for per unit test which should be inclusive of positive control, negative control, calibrators/standard and GST.\n\nitem101per Unit
121.11Mosaic for ANA, ASMA & AMA by Indirect Immunofluorescent (IIF)\n• Each microwell should have separate biochips coated with rat stomach, rat kidney, Rat liver and Hep2 cells.\n• Kit should have positive control for ANA, ASMA and AMA. \n• Test system should be free from need of humidity chamber. \n• Price should be quoted for per unit test which should be inclusive of positive control, negative control, caliberator/standard and GST.\n\nitem111per Unit

AI Tender Summary

OUR REF NO 24417071
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 29-06-2020
Authority
Authority Name All India Institute Of Medical Sciences
Work Description Purchase Of Different Types Of Lab Kits-2 Rheumatoid Factor (RF) By Latex Agglutination n• Kit should have both positive and negative control along with other reagent for Latex agglutination test n• Price should be quoted for per unit test which should be inclusive of positive and negative control and GST. n 3 Anti Nuclear Antibody (ANA) by Indirect Immunofluorescent (IIF). n• Kit should have microwells with Hep 2010 cell mounted on Biochip having high proportion of mitotic cells as well as biochip with primate liver as additional substrate for parallel detection and confirmation. n• Kit should have both positive and negative controls. n• Test system should be free from need of humidity chamber. n• Price should be quoted for per unit test which should be inclusive of positive and negative control and GST. n n 4 Anti LKM 1 by (ELISA) n• Test system should have highly purified antigen (LKM.1—Cytochrome P 450 IID6) coated on microwells. n• Test system should have positive control, negative control and not more than three standard/caliberators. n• Test should have high sensitivity and specificity. n• Total incubation time should be less than 80 minutes. n• Test should be compatible with all ELISA readers. n• Price should be quoted for per unit test which should be inclusive of positive control, negative control, caliberator/standard and GST. n 5 nAnti Neutrophil Cytoplasmic Antibody (ANCA) by Indirect Immunofluorescent (IIF) n• Each microwell should have biochip containing Ethanol fixed granulocyte, Formalin fixed granulocyte and Hep2 cells for better and reliable interpretation. n• Each kit should have positive control for P-ANCA and C-ANCA as well as negative control. n• Test system should be free from need of humidity chamber. n• Price should be quoted for per unit test which should be inclusive of positive and negative control and GST. n 6 Anti-ds DNA by ELISA n• Test system should give quantitative result in (IU/ml). n• Test system should have positive control, negative control, and not more than three standard /caliberators. n• Test should have high sensitivity and specificity. n• Total incubation time should be less than 80 minutes. n• Test should be compatible with all ELISA readers. n• Price should be quoted for per unit test which should be inclusive of positive control, negative control, caliberator/standard and GST. n n 7 Anti Cardiolipin ELISA (IgG, IgM) by ELISA n• Test system should be give quantitative values in PL/ml as per Antiphospholipid Standardisation Laboratory (USA). n• Test system should have positive control, negative control, and not more than three standard/caliberators. n• Test should have high sensitivity and specificity. n• Total incubation time should be less than 80 minutes. n• Test should be compatible with all ELISA readers. n• Price should be quoted for per unit test which should be inclusive of positive control, negative control, caliberator/standard and GST. n 8 Anti Smooth Muscle Antibody (ASMA) by Indirect immunofluorescent (IIF) n• Each microwell should contain rat stomach. n• Kit should have positive and negative controls. n• Test system should be free from need of humidity chamber. n• Price should be quoted for per unit test which should be inclusive of positive control, negative control, caliberator/standard and GST. n 9 Rheumatoid Factor (RF) By Nephelometer. n• Kit should have both positive and negative control. n• Kit should be compatible with all Nephelometers. n• Price should be quoted for per unit test which should be inclusive of positive control, negative control and buffer (if needed for the test) and GST. n n 10 PR3 – ANCA (IgG) by (ELISA) n• Test system should have highly purified microwells coated with mixture of native PR3 and recombinant PR3. n• Test system should have positive control, negative control and not more than three standard/caliberators. n• Test should have high sensitivity higher than 90% and specificity more than 95%. n• Total incubation time should be less than 90 minutes. n• Test should be compatible with all ELISA readers. n• Price should be quoted for per unit test which should be inclusive of positive control, negative control, caliberator/standard and GST. n n n 11 MPO-ANCA (IgG) by (ELISA) n• Test system should have highly purified antigen coated on microwells. n• Test system should have positive control, negative control and not more than three standard/calibrators. n• Test should have high sensitivity higher than 90% and specificity more than 95%. n• Total incubation time should be less than 90 minutes. n• Test should be compatible with all ELISA readers. n• Price should be quoted for per unit test which should be inclusive of positive control, negative control, calibrators/standard and GST. n n 12 Mosaic for ANA, ASMA & AMA by Indirect Immunofluorescent (IIF) n• Each microwell should have separate biochips coated with rat stomach, rat kidney, Rat liver and Hep2 cells. n• Kit should have positive control for ANA, ASMA and AMA. n• Test system should be free from need of humidity chamber. n• Price should be quoted for per unit test which should be inclusive of positive control, negative control, caliberator/standard and GST. n n
Basic Detail
Tender No XX-04/SO(DO)/Clinical Immunology (Med.)/20-21/st.
Bidding Type Tender
Location
City AIIMS, New Delhi
State Delhi
Key Dates
Publish Date 27 May 2020
Submission Date 29 Jun 2020
Open Date 30 Jun 2020
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 1 Lakhs
Exemption Not Available
Document List
TED.pdf
BOQ_588868.xls
Tendernotice_1.pdf
247E5BFD-10AD-4A54-B38E-D5F078D1D533.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

May 27, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
Jun 29, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jun 30, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

TED.pdf

xls

BOQ_588868.xls

pdf

Tendernotice_1.pdf

html

247E5BFD-10AD-4A54-B38E-D5F078D1D533.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders