| 1 | 1 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/ dense soil complete all as specified and directed. | | 90 | Cubic Metre |
|---|
| 2 | 2 | Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) set in cement mortar for 150mm bore complete all as specified & directed. | | 200 | Running Metre |
|---|
| 3 | 3 | Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) set in cement mortar for 100 mm bore complete all as specified & directed. | | 150 | Running Metre |
|---|
| 4 | 4 | S&F PVC (SWR) pipes single socketed 160 mm dia in any length with rubber ring joints laid in trenches or floor complete all as specified and directed.\nMake :- Supreme/ Kisan/ Tirupati/ Finolex/ Prince | | 200 | Running Metre |
|---|
| 5 | 5 | S&F PVC (SWR) pipes single socketed 110 mm dia in any length with rubber ring joints laid in trenches or floor complete all as specified and directed.\nMake :- Supreme/ Kisan/ Tirupati/ Finolex/ Prince | | 150 | Running Metre |
|---|
| 6 | 6 | Removing excavated material n exc 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. | | 72 | Cubic Metre |
|---|
| 7 | 7 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete all as specified and directed. | | 18 | Cubic Metre |
|---|
| 8 | 8 | M&L for PCC 1:3:6 type C2 (using 40 mm graded aggregate) to bed of drain pipes including packing under and haunching against the sides of pipes, after they are laid and tested for 160mm bore pipe complete all as specified and directed.\n | | 200 | Running Metre |
|---|
| 9 | 9 | M&L for PCC 1:3:6 type C2 (using 40 mm graded aggregate) to bed of drain pipes including packing under and haunching against the sides of pipes, after they are laid and tested for 110mm bore pipe complete all as specified and directed. | | 150 | Running Metre |
|---|
| 10 | 10 | M&L for cutting into existing manholes for connecting new drains, making good to pipe of internal dia of pipe 160 mm and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required complete all as specified and directed. | | 15 | Each Pipe |
|---|
| 11 | 11 | M&L for cutting into existing manholes for connecting new drains, making good to pipe of internal dia of pipe 110 mm and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required complete all as specified and directed. | | 15 | Each Pipe |
|---|
| 12 | 12 | M&L for cleaning of SGSW / PVC SWR pipe line 150/ 160 mm bore size by roding or by pressure pump completely excluding connected manhole, any depth and removal of sludge etc to a distance exc 1.5 km but n exc 5 km out of MD land complete all as specified and directed. | | 31000 | Running Metre |
|---|
| 13 | 13 | M&L for cleaning of SGSW / PVC SWR pipe line 100/ 110 mm bore size by roding or by pressure pump completely excluding connected manhole, any depth and removal of sludge etc to a distance exc 1.5 km but n exc 5 km out of MD land complete all as specified and directed. | | 400 | Running Metre |
|---|
| 14 | 14 | M&L for dewatering of soak well or sewage pit of any size and depth upto 3.5m and manholes manually or by using pump and removal of sludge if any outside MD land complete all as specified and directed. | | 600 | Cubic Metre |
|---|
| 15 | 15 | Cleaning of septic tank chamber by removing effluent water and sludge and buried the same in excavated pits, by digging pits in hard/dense soil including removing surplus earth to a distance not exceeding 50 mtr from starting point and filling up the top portion of pit by excavated soil and sprinkling bleaching powder @ 0.5 Kg per Sqm on excavated areas including temporary baricades complete all as specified and directed. | | 630 | Cubic Metre |
|---|
| 16 | 16 | Demolition of brickwork or solid block / stone boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles all as specified and directed. | | 15 | Cubic Metre |
|---|
| 17 | 17 | M&L for providing pre-cast cement concrete block masonry 1:3:6 type C1 solid blocks, exc. 10 cm in width and setting in cement mortar (1:4), complete complete all as specified and directed. | | 15 | Cubic Metre |
|---|
| 18 | 18 | Demolition of precast RCC in ground floor and pavings n exc 15 cm thickness (below or above ground complete all as specified and directed. | | 2 | Cubic Metre |
|---|
| 19 | 19 | M&L for precast cement concrete type B1 1:2:4 (using 20mm graded aggregate) in cover slab for manholes and similar articles with plain faces and set in CM 1:6 complete all as specified and as directed. | | 2 | Cubic Metre |
|---|
| 20 | 20 | S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. | | 110 | Kilogram |
|---|
| 21 | 21 | Taking down of cement plaster of any description on brick including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. | | 130 | Square Metre |
|---|
| 22 | 22 | M&L for 15mm thick rendering in CM 1:4 on brick, concrete surfaces with WPC @3% by weight of cement and finishing the surfaces even and fair complete all as specified and directed.\nNote: WPC shall be measured and paid separately. | | 50 | Square Metre |
|---|
| 23 | 23 | Supply only integral water proofing compound complete all as specified and directed.\n | | 5 | Kilogram |
|---|
| 24 | 24 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and directed. | | 10 | Running Metre |
|---|
| 25 | 25 | Demolition of cement conrete un reinforced in floors n exc 15 cm thickness in ground floor (below or above GL) completed all as specified and directed . | | 6 | Cubic Metre |
|---|
| 26 | 26 | Material and labour for PCC 1:4:8 type D2 (using 40mm graded aggregate) as in foundation filling and mass concrete etc complete all as specified and directed. | | 6 | Cubic Metre |
|---|
| 27 | 27 | M&L for 15mm thick rendering in CM 1:4 on brick, concrete surfaces and finishing the surfaces even and smooth without using extra cement complete all as specified and directed. | | 80 | Square Metre |
|---|