Tamil Nadu Energy Company Limited has published Annual Maintenance Contract Of Switchyard And Transformers. Submission Date for this Tender is 09-06-2020. Washers Tenders in NTECL Tamil Nadu. Bidders can get complete Tender details and download the document.
Name of Work:Annual maintenance contract of switchyard and transformers | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | BOQ (PART#A- SWITCHYARD RELATED) | BI01010001010000000000000515BI0100001112 | ||
2 | 2 | Cleaning and connection tightness checking of one set of CVT/ LA /Post Insulator. | ITEM1 | 100 | No |
3 | 3 | Cleaning and connection tightness checking of Bushings /Wave trap in one phase . | ITEM2 | 75 | No |
4 | 4 | Ensuring tightness of 400KV connection in one equipment in one phase of a bay (without equipment cleaning) | ITEM3 | 30 | No |
5 | 5 | Cleaning and tightness checking of Suspension / Tension Insulator ( Polymer) with Jumper connector and structure in one phase . | ITEM4 | 30 | No |
6 | 6 | Replacement of damaged insulator strings in 400KV switchyard gantry/tower, TG A-row e.t.c | ITEM5 | 2 | No |
7 | 7 | Replacement of CVT/LA/Post Insulators/Wavetrap including removal and reconnection of terminal connectors, 400 KV moose conductors and jumpers | ITEM6 | 10 | No |
8 | 8 | Disconnection & Reconnection of moose conductor from HV terminals of 400 KV bushing of Transformer/Reactor ( Per phase) | ITEM7 | 20 | No |
9 | 9 | Replacement of Jumper between Overhead line and Bushing / CVT in one phase and ensuring tightness of hardware of all related O/H connections. | ITEM8 | 5 | No |
10 | 10 | Operation of Articulated Boom Lift | ITEM9 | 325 | Oprn |
11 | 11 | Stringing of Moose conductor in AIS yard | ITEM10 | 500 | Meter |
12 | 12 | Jointing of snapped 400KV OH line in switchyard | ITEM11 | 2 | No |
13 | 13 | PM of CVT Marshalling box/Junction box | ITEM12 | 20 | No |
14 | 14 | Recovery of gas, vacuuming and SF6 gas filling in GIS duct compartment | ITEM13 | 8 | No |
15 | 15 | SF6 gas top up in GIS duct compartment | ITEM14 | 50 | No |
16 | 16 | Assistance for internal inspection of a section and replacement of PRD/view glass/molecular filters in GIS duct compartment and box up or Replacement of SF6 pressure gauges / density switches in GIS ducts | ITEM15 | 6 | No |
17 | 17 | SF6 gas leak detection in GIS components like PRDs, pressure gauges, valves, flanges,joints etc. | ITEM162 | 12 | No |
18 | 18 | Oil top up in breaker pole in case of low oil level | ITEM16 | 3 | No |
19 | 19 | Assistance for Insulation spacer replacement | ITEM17 | 2 | No |
20 | 20 | Assistance for replacement of Bus support insulator /surge arrester/ male or female or both contacts of bus bar or isolator or earth switch/gas valve replacement | ITEM18 | 3 | No |
21 | 21 | Assistance for replacement of GIS Breaker fixed main/ fixed arcing/ moving main/ moving arcing contact/ nozzle/ nozzle cover | ITEM19 | 2 | No |
22 | 22 | Assistance for replacement Isolator/Earth switch operating mechanism/ CT/PT in GIS as per scope | ITEM20 | 2 | No |
23 | 23 | Assistance for dismantling and reinstallation /replacement of gas compartments other than breakers or 400KV breaker pole or SF6 to air bushing in one phase | ITEM21 | 6 | No |
24 | 24 | Assitance in replacement of individual components in breaker operating mechanism as listed in SOW | ITEM22 | 3 | No |
25 | 25 | Removal & Refilling hydraulic oil in Breaker hydraulic oil tank | ITEM23 | 2 | No |
26 | 26 | GIS bay daily checks as per the scope | ITEM25 | 700 | No |
27 | 27 | Weekly Downloading of data from SEMs and Monitoring of CVT secondary voltages | ITEM26 | 52 | No |
28 | 28 | Cleaning of bus ducts inside GIS | ITEM27 | 350 | Per bay |
29 | 29 | Cleaning of bus ducts outside GIS | ITEM28 | 150 | Per bay |
30 | 30 | Cleaning of Panels | ITEM29 | 150 | No |
31 | 31 | Weekly Operational and Maintenance checks as per the scope in GIS | ITEM290 | 52 | Nos |
32 | 32 | Assistance in Electrical Testing | ITEM291 | 150 | Nos |
33 | 33 | Weekly IR Thermovision Scanning & Overhead conductor monitoring in Switchyard | ITEM2925 | 52 | No |
34 | 34 | Maintenace of SF6 Gas Liquefaction machine | ITEM2900 | 3 | No |
35 | 35 | Shifting of SF6 Liquefaction Machine | ITEM250 | 10 | Nos |
36 | 36 | Cleaning jobs inside the switchyard- weed removal, levelling of metal, cleaning of drainage, any other miscellaneous jobs | ITEM2911 | 200 | No |
37 | 37 | Daily checks on Lightning arresters , Battery and Battery charger. | ITEM2912 | 325 | No |
38 | 38 | 220V Battery bank cleaning | ITEM2913 | 192 | No |
39 | 39 | 48V Battery bank cleaning | ITEM2914 | 48 | No |
40 | 40 | Top up of Electrolyte in Ni Cd battery banks | ITEM2915 | 25 | No |
41 | 41 | Diesel Engine Battery cleaning & tightness check | ITEM2916 | 192 | No |
42 | 42 | Weekly Battery Room Cleaning | ITEM2917 | 52 | No |
43 | 43 | Ni-Cd Battery bank Capacity testing | ITEM2918 | 20 | No |
44 | 44 | Full set readings of 220V Battery bank | ITEM29189 | 100 | No |
45 | 45 | Full set readings of 48V Battery bank | ITEM29189000 | 25 | No |
46 | 46 | Readings of Diesel Engine Battery | ITEM29189777 | 24 | No |
47 | 47 | Replacment of Diesel Engine battery | ITEM2912444 | 6 | No |
48 | 48 | Replacement of cells in Ni Cd Battery banks | ITEM291344410000 | 10 | No |
49 | 49 | Conditioning of new cells for replacement. | ITEM2914444 | 10 | No |
50 | 50 | Boost Charging of Ni Cd Battery bank | ITEM2915444 | 15 | No |
51 | 51 | Identification of DC earth fault | ITEM2916777 | 20 | No |
52 | 52 | PM Jobs on DG set as per the scope | ITEM2917555 | 4 | No |
53 | 53 | PM Jobs of DAVR / GRP | ITEM2918777 | 6 | No |
54 | 54 | Splicing & termination of Optic Fibre Cable termination as per the scope | ITEM291897899 | 4 | No |
55 | 55 | RJ 45 cable crimping and termination as per scope | ITEM2912457 | 12 | Nos |
56 | 56 | Packing Numerical relays/electronic cards/ electrical test equipments for dispatch to vendor premises by courier. | ITEM2913456 | 15 | No |
57 | 57 | Replacement of Protection/control relays in control panels | ITEM2914489 | 10 | No |
58 | 58 | Attending minor control circuit problems / condition monitoring of equipment | ITEM2915458 | 300 | No |
59 | 59 | Weekly monitoring, stock keeping & upkeeping of testing equipments/spares | ITEM2916252 | 52 | No |
60 | 60 | Preventive Maintenance of Control / Protection Panels | ITEM291744 | 60 | No |
61 | 61 | 110V Ni Cd Battery cleaning | ITEM2918444 | 48 | No |
62 | 62 | Full set of 110V Ni Cd Battery bank | ITEM2918944 | 48 | No |
63 | 63 | Painting of Support structure for Insulators at Turbine building | ITEM2912455 | 3 | No |
64 | 64 | Testing of 11KV,33KV transformers | 78965ITEM2913444 | 30 | No |
65 | 65 | Testing of GT/ST/UT | ITEM2914333 | 10 | No |
66 | 66 | Assistance during SCC/OCC Testing of Generator | ITEM2915222 | 2 | No |
67 | 67 | Assistance for Relay testing /relay configuration / CT stability testing | ITEM2916000 | 100 | No |
68 | 68 | BOQ( PART#B - TRANSFORMER RELATED) | ITEM291711 | ||
69 | 69 | Preventive Maintenance of 200 MVA Generator transformer | ITEM291800 | 6 | No |
70 | 70 | Preventive Maintenance of 80 MVA Station transformer | ITEM291892 | 2 | No |
71 | 71 | Preventive Maintenance of Unit Transformers/ Unit Auxiallary transformer(16/45 MVA) | ITEM411 | 6 | No |
72 | 72 | Preventive Maintenance of transformers up to 15 MVA | ITEM500 | 35 | No |
73 | 73 | Disconnection and reconnection of 21KV side flexibles for testing needs/ bellow replacement , maintenance etc. in one phase of GT | ITEM600 | 6 | No |
74 | 74 | Disconnection and reconnection of 11KV side flexibles / cables for testing needs in ST/UT | ITEM700 | 6 | No |
75 | 75 | Disconnection and reconnection of 21KV side flexibles for testing needs/ bellow replacement etc. in one phase of UT | ITEM800 | 6 | No |
76 | 76 | Replacement of bellows in GT/ UT/Bus Duct | ITEM900 | 6 | No |
77 | 77 | Disconnection and reconnection of LV side and HV side connections or flexibles for testing needs/ bellow replacement / transformer replacement etc. in 11KV/433 V transformers or 11KV /3.3KV transformers or 11KV /33KV transformers | ITEM1000 | 30 | No |
78 | 78 | PM of GT/ST/UT Marshalling box | ITEM1114 | 35 | No |
79 | 79 | Inspection/checks in HT/LT transformers and maintaining record of them as per instruction of EIC | ITEM1215 | 52 | No |
80 | 80 | Washing of GT/ ST/UT using soap and water | ITEM1314 | 30 | No |
81 | 81 | Processing of Transformer oil in transformers with oil quantity upto 12 KL ( UAT / ESPT/CW/CT/ SWYD etc.) | ITEM1415 | 8 | No |
82 | 82 | Processing of Transformer oil in transformers having oil quantity above 12 Kl ( 200 MVA GT/ ST / UT/ BR etc., ). | ITEM1545 | 6 | No |
83 | 83 | Processing of Transformer oil in Transformer tanks | ITEM16245 | 6 | No |
84 | 84 | Shifting of 10 KI. Filtration plant or 30 KL oil storage tank or 15 KL oil storage tank from one location to other in the main plant / switchyard / offsite | ITEM1644 | 6 | No |
85 | 85 | Shifting of 4.5 KI or 2 KL or 1 KL Filtration plant or 5 KL oil storage tank from one location to other in the main plant / switchyard / offsite | ITEM17422 | 6 | No |
86 | 86 | Replacement of defective cooling fan motors in GT/ST/UT | ITEM184474 | 80 | No |
87 | 87 | Transferring of oil . | ITEM19444 | 100 | Oprn |
88 | 88 | Attending breakdown works in Transformers | ITEM204444 | 100 | No |
89 | 89 | Replacement of oil pump in G.T/ U.T/S.T etc., | ITEM21422 | 5 | No |
90 | 90 | Replacement of Flow meter in the power transformer . | ITEM22022 | 20 | No |
91 | 91 | Draining of water from the transformer yard in G.T / U.T/S.T and all other transformer areas. | ITEM23122 | 20 | No |
92 | 92 | Shifting of filled oil drums | ITEM25144 | 75 | No |
93 | 93 | Shifting of empty oil drums from main plant / switchyard / Offsite to central stores/scrapyard | ITEM264444 | 75 | No |
94 | 94 | Replacement of HV bushing or its gasket in 21/420 KV Generator transformer/ Station Transformer / 400 KV Shunt reactor. | ITEM100017 | 1 | No |
95 | 95 | Replacement of oil seals / Gaskets of HV/LV/ Neutral bushings / PRD / MOG of the various transformer. 0-16 MVA Transformers | ITEM111410 | 8 | No |
96 | 96 | Replacement of PRD/SPR/MOG or Gasket for LV bushings / Neutral bushings. Transformer GTs, UTs, ST s or shunt reactor | ITEM121511 | 3 | No |
97 | 97 | Air cell replacement work including MOG inspection of GT/UT/ST/SR etc.. transformers (40/80/200 MVA etc) | ITEM131412 | 2 | No |
98 | 98 | Air cell replacement work including MOG inspection of UAT/ SAT/ etc ( up to 40 MVA) | ITEM141513 | 2 | No |
99 | 99 | Replacement of silicagel in running transformers breathers. | ITEM154514 | 200 | No |
100 | 100 | Oil top up in various transformers up to required level. ( With out involvement of Hydra, filter machine) | ITEM1624515 | 150 | No |
101 | 101 | Moving of transformers (shifting) on rails ( Transformer weight above 150 MT) | ITEM164416 | 100 | Mtrs |
102 | 102 | Moving of transformers (shifting) on rails (Transformer with weight > 75 MT but < 150 MT) | ITEM1742217 | 20 | Mtrs |
103 | 103 | Moving of transformers (shifting) on rails (Transformer with weight up to 75 MT) | ITEM18447418 | 20 | Mtrs |
104 | 104 | Cleaning of Generator transformer coolers with compressed air/ manual cleaning | ITEM1944419 | 3 | No |
105 | 105 | Defective radiator replacement in LT transformers | ITEM20444420 | 20 | No |
106 | 106 | Polythene covering of HT transformers field devices like PRV, CT, Buchholz relay etc | ITEM2142221 | 30 | No |
107 | 107 | Polythene covering of LT transformers field devices like PRV, Buchholz relay etc | ITEM2202222 | 50 | No |
108 | 108 | Oil sampling of HT/LT transformers/ESP transformers in SS bottles/ OIL SYRINGES and tagging as per instruction of EIC. | ITEM23122333 | 300 | No |
109 | 109 | Weekly thermovision scanning of Transformers | ITEM25144444 | 52 | No |
110 | 110 | Oil BDV and ppm checking | ITEM264444444 | 50 | No |
111 | 111 | Courier service from NTECL Vallur site to R&D, NTPC , New Delhi noida . 0 - 10 Kgs Forward Journey/Return Journey. | ITEM1045550000 | 30 | Trip |
112 | 112 | Courier service from NTECL Vallur site to HOSUR lab . 0 - 10 Kgs Forward Journey/Return Journey. | ITEM24444 | 30 | Trip |
113 | 113 | Replacement of defective ESP rectiformer | ITEM3044556 | 2 | No |
114 | 114 | Breakdown maintenance of ESP rectformer. | ITEM445689 | 2 | No |
115 | 115 | Preventive maintenance of ESP rectiformer as mentioned in the scope of work. | ITEM578569 | 80 | No |
116 | 116 | Deweeding in EHV/LT Transformer yard ( Rate per transformer yard) | ITEM6456321 | 100 | No |
117 | 117 | Replacement of LT transformer ( 1 MVA - 2 MVA) | ITEM714555 | 2 | No |
118 | 118 | Spray painting of external surfaces of HV & EHV Transformer | ITEM808455 | 6000 | Sq m |
119 | 119 | Labeling / Names writing for Marshalling boxes & transformers. | ITEM945555 | 200 | Sq Ft |
120 | 120 | Assistance for internal inspection of GT/ST/UT/Bus Reactor/OLTC | ITEM10455578955 | 1 | No |
121 | 121 | Preventive Maintenance of 21 KV bus VTs | ITEM114444 | 20 | No |
122 | 122 | Preventive Maintenance / Break down works of HT/ LT Switchgear bus duct | ITEM1247474 | 150 | No |
123 | 123 | Bus duct Air Pressurisation system checks and defects attending | ITEM134562 | 20 | No |
124 | 124 | IPBD busduct checking / air leakage attending works | ITEM1444444 | 100 | No |
125 | 125 | IPBD / SPBD busduct work insulator replacemen works | ITEM15478555 | 20 | No |
126 | 126 | Supply of 10KL/ 12 KL Oil filter machine on hire basis for oil filteration / Dry out process /oil draining & refilling as per sow | ITEM16244444 | 20 | Operation |
127 | 127 | Supply of 2KL/4.5KL/6KL Oil filter machine on hire basis for oil filteration / Dry out process /oil draining & refilling as per sow | ITEM16444445 | 10 | Operation |
128 | 128 | (PART#C -COMMON TO BOTH SWYD AND TRANSFORMERS ) | ITEM171458 | ||
129 | 129 | Providing scaffolding at locations for maintenance works | ITEM187777 | 20 | No |
130 | 130 | Providing of 20T tyre mounted crane/hydra with telescopic extendable boom up to 50 feet along with operator & diesel | ITEM19777777 | 50 | Hrs |
131 | 131 | Providing of 12T hydra crane along with operator & diesel | ITEM2011111 | 100 | Hrs |
132 | 132 | Providing tractor with trailor alongwith driver on hire basis for shifting of materials. | ITEM21111111456 | 100 | Hrs |
133 | 133 | Shifting of materials either manually or by hand trolley | ITEM2244555 | 100 | No |
134 | 134 | Supply of skilled manpower for unscheduled works/overhaul/major breakdown works | ITEM23444555 | 200 | Per Op |
135 | 135 | Supply of unskilled manpower for unscheduled works/overhaul/major breakdown works | ITEM21111111456000 | 200 | Per Oprn |
136 | 136 | Painting jobs /Miscellaneous fabrication jobs invloving Metal Cutting/Welding/Drilling etc. | ITEM22445550000 | 100 | No |
137 | 137 | Maintenance of earth pit | ITEM23444555000 | 20 | No |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail