Supply,Installation,Testing,Commissioning And Training Of Spares For Pump/Turbine (P/T) Vibration Detectors Along With Alarm Units And Sensors For Slbhes, Srisailam Dam West, Nagarkurnool Dist, Telangana-509326-Telangana

Telangana Power Generation Corporation Limited has published Supply,Installation,Testing,Commissioning And Training Of Spares For Pump/Turbine (P/T) Vibration Detectors Along With Alarm Units And Sensors For Slbhes, Srisailam Dam West, Nagarkurnool Dist, Telangana-509326. Submission Date for this Tender is 06-10-2020. Spare Part Tenders in Telangana. Bidders can get complete Tender details and download the document.




Tender Notice

24395959
Corrigendum : Supply,Installation,Testing,Commissioning And Training Of Spares For Pump/Turbine (P/T) Vibration Detectors Along With Alarm Units And Sensors For Slbhes, Srisailam Dam West, Nagarkurnool Dist, Telangana-509326
Open Tender
Indian
Telangana
06-10-2020

Tender Details

Supply,Installation,Testing,Commissioning And Training Of Spares For Pump/Turbine (P/T) Vibration Detectors Along With Alarm Units And Sensors For Slbhes, Srisailam Dam West, Nagarkurnool Dist, Telangana-509326 1. P/T Vibration EquipmentAuxiliary Supply:1-Phase, 100V Ac, 50HzAccelerometer For Head Cover Vibration - 1 For Each Unit.Range: 0-5 G (Acceleration Type Measurement)Eddy Current Sensor Sets For Shaft X And Y Directions---2 For Each UnitRange: 0 - 900 Microns (Displacement Type Measurement)It Includes All Accessories Like Armoured Extension Cable, Proximity Probe Driver And Monitoring Systems EtcRequired Output: 4 To 20 Ma Dc For Connecting Scada Along With Alarm And Trip, Contacts Are Required For Each Vibration Measurement Separately, Alarm And Trip Should Be Field Adjustable. Display Unit Is Also Required For All Head Cover, X And Y Vibration Measurements,

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 16/06/2020 1 TELANGANA POWER GENERATION CORPORATION LIMITED-CE OM SLBHES SRISAILAM Due date extension 06-07-2020
2 08/07/2020 0 TELANGANA POWER GENERATION CORPORATION LIMITED-CE OM SLBHES SRISAILAM Due date extension 29-07-2020
3 30/07/2020 1 TELANGANA POWER GENERATION CORPORATION LIMITED-CE OM SLBHES SRISAILAM Due date extension 19-08-2020
4 19/08/2020 0 TELANGANA POWER GENERATION CORPORATION LIMITED-CE OM SLBHES SRISAILAM Due date extension 02-09-2020
5 15/09/2020 0 TELANGANA POWER GENERATION CORPORATION LIMITED-CE OM SLBHES SRISAILAM due date extension 06-10-2020

Key Value

Document Fees
Refer document
EMD
INR 3845.0 /-
Tender Value
Refer document

BOQ Items

Item IDItem CodeItem NameItem DescriptionAgree NIT QuantityUOMItem SpecificationQuantityPart NumberAction
237455VIBDTECTP/T VIBRATION EQUIPMENT Auxiliary Supply:1-phase, 100V AC, 50Hz Accelerometer for Head Cover vibration - 1 for each unit. Range: 0-5 G (Acceleration type measurement) Eddy Current Sensor Sets for Shaft X and Y directions---2 for each unit Range: 0 - 900 microns (Displacement type measurement) It includes all accessories like armoured extension cable, Proximity probe driver and monitoring systems etc Required Output: 4 to 20 mA DC for connecting SCADA along with Alarm and trip, Contacts are required for each vibration measurement separately, Alarm and Trip should be field adjustable. Display unit is also Required for all head cover, X and Y vibration measurementsP/T VIBRATION EQUIPMENT Auxiliary Supply:1-phase, 100V AC, 50Hz Accelerometer for Head Cover vibration - 1 for each unit. Range: 0-5 G (Acceleration type measurement) Eddy Current Sensor Sets for Shaft X and Y directions---2 for each unit Range: 0 - 900 microns (Displacement type measurement) It includes all accessories like armoured extension cable, Proximity probe driver and monitoring systems etc Required Output: 4 to 20 mA DC for connecting SCADA along with Alarm and trip, Contacts are required for each vibration measurement separately, Alarm and Trip should be field adjustable. Display unit is also Required for all head cover, X and Y vibration measurementsYesNoP/T VIBRATION EQUIPMENT Auxiliary Supply:1-phase, 100V AC, 50Hz Accelerometer for Head Cover vibration - 1 for each unit. Range: 0-5 G (Acceleration type measurement) Eddy Current Sensor Sets for Shaft X and Y directions---2 for each unit Range: 0 - 900 microns (Displacement type measurement) It includes all accessories like armoured extension cable, Proximity probe driver and monitoring systems etc Required Output: 4 to 20 mA DC for connecting SCADA along with Alarm and trip, Contacts are required for each vibration measurement separately, Alarm and Trip should be field adjustable. Display unit is also Required for all head cover, X and Y vibration measurements6.00None