Repair Maint Of Domestic Summer Appliances Including Connected Works In Sector B Under Ge Utility Ambala Cantt, AMBALA CANTT-Haryana

Military Engineer Services-MES has published Repair Maint Of Domestic Summer Appliances Including Connected Works In Sector B Under Ge Utility Ambala Cantt. Submission Date for this Tender is 20-06-2020. Air Conditioner Tenders in AMBALA CANTT Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

24394096
Corrigendum : Repair Maint Of Domestic Summer Appliances Including Connected Works In Sector B Under Ge Utility Ambala Cantt
Open Tender
Indian
Haryana
AMBALA CANTT
20-06-2020

Tender Details

Repair Maint Of Domestic Summer Appliances Including Connected Works In Sector B Under Ge Utility Ambala Cantt

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 13-Jun-2020 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 20-06-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 24000.0 /-
Tender Value
INR 12 Lakhs /-

BOQ Items

Name of Work: Repair/maint of domestic summer appliances including connected works in Sector ‘B’ under GE (U) Ambala Cantt.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Disconnecting the unserviceable compressor sealed unit of deep freezer of any make and type 230 V single phase of capacity 500 ltr by opening the nut bolt and supply and fixing new compressor suitable for 500 ltr deep freezer of existing make Kirloskar/Tachumsha /Voltas/Sidhwal procured from authrised dealer and fixing the compressor in original position and testing the same (with two years guarantee) including supply and charging Refrigerant R-134 gas and fixing copper tube Capilary, over load relay and starting relay etc. and making connection and put working condition complete all as specified and as directed by Engr-in-Charge. 3 Each Job
2 2 Description all as per item No 1.00 above but for 320 ltr capacity deep freezer and ditto. 3 Each Job
3 3 Description all as per item No 1.00 above but for 205 ltr capacity deep freezer and ditto. 3 Each Job
4 4 Disconnecting the electric and Water connections and taking out the existing unserviceable compressor of any make from water cooler storage type capacity 150 ltrs from any location and supply and fixing new compressor suitable for 150 ltr capacity water cooler with two years guarantee alongwith test certificate from manufacturer and cleaning of condenser by machine doing vaccum the whole system and supply with and including charging of gas and other necessary lubricants including reconnecting the electric and water connections & testing complete all as directed by Engr-in-charge. Make Tecumsha/Voltas/Kirloskar/Sidhwal. 8 Each Job
5 5 Description all as per item No 4.00 above but Water cooler of Cap 40 Ltrs and ditto. 8 Each Job
6 6 Disconnecting the electric connection and taking out unserviceable condenser fan motor 1/10, 1/16 HP from water cooler cap.150 Ltr and supply and replace with new motor single phase AC 220 V of same Cap including reconnecting the electric connections and testing complete all as directed by Engr-in- Charge.\nMake : AE, Cromption Greaves / Cool Master/Bajaj. 8 Each Job
7 7 Description all as per item No. 6.00 above but fan motor 1/32 HP and Water cooler of Capacity 40 Ltrs and ditto. 8 Each Job
8 8 Disconnecitng the electric connections and taking out the unserviceable condenser coil fins type and supply & fixing new condenser coil fins type as per existing size & patterns for Water Coolers 150 ltrs ltrs capacity complete all as specified and directed by Engr-in-Charge. 7 Each
9 9 Description all as per item No. 8.00 above but for water cooler 40 ltrs capacity and ditto. 10 Each
10 10 Cutting the rusted unserviceable base of 150/40 Ltr Capacity. water cooler body and material and labour fabrication of New Base made of MS sheet 20 gauge & angle as per existing size and thickness and shape incl welding or small patches as directed by Engr - in - Charge. 8 Each Job
11 11 Dismantling the evaporator/cooling coil of water cooler capacity 150/40 Ltrs, checking the leakages of gas and rectify the leakages by gas welding or as in other means as directed by Engr-in-Charge. 7 Each Job
12 12 M & L charging Gas F-22 in the water cooler Cap. 150/40 ltrs including testing and satisfactory commissioning all as directed. 10 Each
13 13 Taking out the Water Cooler Tank from water cooler 150/40 ltrs capacity & repair the tank with brazing welding etc to stop the leakage of tank incl provn of inserting glass wool tarpaulin sheet etc and repair to cooling coil and refixing in original position & testing and commissioning complete all as specified and directed by Engr-in-Charge. 10 Each Job
14 14 Cleaning & removing the existing paint from old steel surfaces of water coolers capacity 150 /40 Ltrs by rubbing & preparing the surface smooth & applying one coat of synthetic enamel paint by spray gun machine of colour as approved by Engr-in-Charge including writing SM/MES No. on water cooler with paint complete all as specified and directed. 10 Each Job
15 15 Taking out rusted/unserviceable MS sheet from water cooler of capacity 150/40 ltrs, supply & fixing new MS sheet of 22 SWG including nut bolts & screws and welding if required, painting with two coats of synthetic enamel grey paint over a coat of red oxide primer complete all as directed. 15 Sqm
16 16 Supply & fixing in replacement of complete Top door made out of stainless steel 20 guage sheet with handle and locking arrangement with double keys including door gasket and recommended insulation material and PVC inner sheet of suitable thickness for 150/40 Ltr capacity water cooler as per eixsiting size and shape, welding work nuts bolts & washers all as directed. 8 Each Job
17 17 Supply and Fix in replacement of PVC connections 15 mm dia bore with PTMT nuts of length 900 mm complete all as specified and directed. 12 Each
18 18 Supply and Fix GI Tubing 15 mm dia medium grade with all fittings in walls with suitable size clamps/saddles including taking down old unsv /rusted GI tubing and cutting in wall complete all as specified and directed by Engr-in-charge. 12 RM
19 19 Supply and Fixing Stop vlave cast copper alloy screw down high pressure with crutch or butterfly handle screwed both ends for iron pipe 15 mm dia bore including taking down old unsv /rusted stop valve complete all as specified and directed by Engr-in-charge. 12 Each
20 20 Disconnecting from mains and servicing of Refrigerator/Deep freezer of Capacity 165 to 500 Ltrs including detecting the leakage of gas and refilling, cleaning of cooling coil, condenser, compressors, with vacuum cleaner OR cleaning solution including checking the servicibility of electrical/electronic circuits relays, wiring kit, thermostat switch with knobs, etc., and keeping the Refrigerator unit in satisfactory working condition all as specified and as directed by Engineer-in-Charge.\nNote :- 1. Replacement of defective parts shall be measured & paid separately as supply only under relevant items and Labour charges for fixing of parts shall be included in unit rate of this item as quoted. 30 Each Job
21 21 Supply only Thermostat switch with Knob for Refrigerator/Deep freezer of 165 to 500 ltrs capacity Make :- Indfoss or Renutrol 12 Each
22 22 Supply only Starting relay 1/6 H.P. Open type with O.L.P. for Refrigerator/Deep freezer of 165 to 500 ltrs capacity Make : KOI / Whirlpool 12 Each
23 23 Supply only Starting relay 1/8 H.P. open type with O.L.P. for Refrigerator/Deep freezer of 165 to 500 ltrs capacity Make : KOI / Whirlpool 12 Each
24 24 Supply only copper filter single capillary pencil type for Refrigerator/Deep freezer of 165 to 500 ltrs capacity 12 Each
25 25 Supply only Vegitable tray PVC suitable for Refrigerator of 165 to 500 ltrs capacity Make Whrilpool, LG 12 Set of two
26 26 Supply only Defrost tray suitable for Refrigerator of 165 to 500 ltrs capacity Make Whirlpool/LG 8 Each
27 27 Supply only PVC ice tray flexible of existing type, make and size for Refrigerator of 165 to 500 ltrs capacity. 7 Each
28 28 Supply only Refrigerator bottle shelf suitable for Refrigerator of 165 to 500 ltrs capacity Make Whirlpool/LG 7 Each
29 29 Supply only Waste water tray for Refrigerator of 165 to 500 ltrs capacity. 7 Each
30 30 Supply only Freezer door for Refrigerator of 165 to 500 ltrs capacity. 7 Each
31 31 Supply only Door Lock for Refrigerator of 165 to 500 ltrs capacity 5 Each
32 32 Supply only Chiller tray for Refrigerator of 165 to 500 ltrs capacity 5 Each
33 33 Supply only ice tray for Refrigerator of 165 to 500 ltrs capacity 6 Each
34 34 Supply only Door switch for Refrigerator of 165 to 500 ltrs capacity. 6 Each
35 35 Supply only Interior light fittings with bulb for Refrigerator of 165 to 500 ltrs capacity. 7 Each
36 36 Supply only Door handle suitable for Refrigerator of 165 to 500 ltrs capacity. 7 Each
37 37 Supply only Refrigerator compartment Glass for Refrigerator of 165 to 500 ltrs capacity. 5 Each
38 38 Disconnecting from mains and taking down the unserviceable compressor sealed unit of Refrigerator of 165 to 180 ltrs capacity and providing and fixing New Compressor suitable for 165 to 180 ltr Refrigerator & testing the same with two years gurantee including supply and charging of the refrigernt gas F-12 , R-134A and all other copper tubes, capillary, filter and put in working condition all as directed by Engineer-in-Charge. Make : Kirloskar/Whirlpool/Godrej/Sumsung/Voltas.\nNote :- The Unit Rate quoted by the contractor shall deem to be included for replacement of filter, cleaning of condenser Nuts & bolts and making necessary connection and testing complete. 12 Each Job
39 39 Description all as per item No. 38 above but capacity of the refrigerator 280/ 300/310 Ltrs and ditto. 12 Each Job
40 40 M & L one coat of spray painting with synthetic enamel paint, any shade with machine as directed to refrigerator 165/310 lts cap including anticorrosive black paint on compressor, condenser coil incl Scratching out the existing paint with sand paper and filling up the scratches with putty including writing SM/MES No. on refrigerator with paint complete all as specified and directed by Engineer-in- Charge. 6 Each Job
41 41 M & L charging gas refrigerant F-12/ R-134A after detecting or rectify the leakages incl cutting welding for Refrigerant cap. 165 Ltrs to 310 ltrs of any Make 30 Each
42 42 Taking out unserviceable evaprotator/freezer from the refrigerator and supply & fixing evaporator/freezer made out of aluminium press type suitable for 280/300/310 ltr capacity Refrigerator with freezer frame and door including connection, Make Whirlpool/Godrej/Kelvinator/Voltas 12 Each
43 43 Description all as per item No. 42 above but capacity of the refrigerator 165 to 180 Ltrs and ditto. 7 Each
44 44 Disconnecting the Electric & Water connection of the Desert Cooler incl taking down from its existing location removal of unserviceable side panel, Top cover W/Tank side support, grill regulator etc. Scratching old paint with sand paper complete cleaning inner & outer surfaces of the Desert Cooler body to make the surface smooth and painting the inner surfaces & Grills with one coat of black anticorrosive paint and outer surfaces with one coat of alluminium/ hammerton paint of 1st quality with spray machine and including checking the servicibility of Fan and submersible (little ) pump , selector switchs etc., and fixing the Desert Cooler at existing location including oiling & Greasing and making electric & water connections and testing the same including writing SM/MES No. on Desert Cooler with paint complete all as specified and directed by Engineer-in- Charge.\nNote :- 1. Replacement of defective parts shall be measured & paid separately under relevant items as supply only and Labour charges for fixing of parts shall deem to be included in unit rate quoted. 60 Each Job
45 45 Supply only Capacitor 4 Mfd for desert cooler Make Bentex/Unistar 60 Each
46 46 Suppy only wood wool Cooler Pad set of Three 70x70 cms having wt of 500 gms each set for desert cooler. 60 Each Set of three
47 47 Supply only Selector Switch with Knob for desert cooler. 25 Each
48 48 Supply only MS Front Show grill for desert cooler as per exisitng size at site. 25 Each
49 49 Supply only Plastic front Show grill for desert cooler as per existing size at site. 12 Each
50 50 Supply only PVC Pipe 1/2 " with Elbow plastic as per exisiting length set of three 20 Each
51 51 Supply only distirbutor box PVC for desert cooler. 20 Each
52 52 Supply and fix in repair Wooden ply of size 6mm thick of size 3’x6’ water proof for desert cooler/window AC all as directed. 20 Each
53 53 Supply only aluminium blades for fan motor of desert cooler. 20 Each
54 54 Disconnecting from the mains and Taking out the existing unserviceable fan motor of cooler and supply and fixing new fan motor 1/10 HP capacity 3 speed single phase 240 volts for desert cooler including reconneting the electric connection and testing complete all as specified and directed by the Engr-in-charge. \nMake Crompton greaves or Khaitan or Uttam/ Bajaj. 40 Each
55 55 Disconnecting from the mains and Taking out the existing unserviceable Water lifitng pump vertical pump/little submersible pump and supply and fixing new Water lifting pump heavy duty single phase 240 volts for desert cooler including reconneting the electric connection and testing complete all as specified and directed by the Engr-in-charge. \nMake Crompton greaves or Khaitan or Uttam/ Bajaj. 40 Each
56 56 Taking down old U/s or rusted Angle iron stand and replace it with new angle iron stand for desert cooler/window AC made out of angle iron 40x40x5mm of required size with four legs including Leg support duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer complete all as directed by Engr-in-Charge. 160 Kg
57 57 Taking down old U/s or rusted MS Side panels and repalce it with new MS Side panel set of three for desert cooler of exisiting size at site including wood wool pad set of three for desert cooler of size 70x70 cms having weight 500 gms each set complete all as specified and directed by Engr-in-Charge. 8 Each Job
58 58 Collecting of unserviceable voltage stabilizer of capacity 0.5 to 2 KVA from the MES store yard (AGE E/M - I ) , transporting to workshop and dismantling for locating the fault including checking the serviceablity of electrical/electronic circuits relays and repalcement of defective spare parts , reassembling after making connections, testing by applying low and high voltage input to get the 230 volts correct output and transporting back the same to MES sotre yard after repair complete all as specified and directed by Engr-in-charge\n Note :- 1. Replacement of defective parts shall be measured & paid separately under relevant items as supply only and Labour charges for fixing of parts shall deem to be included in unit rate quoted. 12 Each Job
59 59 Description all as per item ser No. 58 herein before but voltage stabilizer of capacity 3 kva to 5 KVA and ditto. 12 Each Job
60 60 Supply only Volt meter (Analog) 0 to 300 volts any type shape single phase 50 Hz AC supply for Voltage stabilizer of Cap 0.5 to 5 KVA.\n Make AE, MIECO, Rishabh. 10 Each
61 61 Supply only Digital type Volt meter 0 to 300 volts any type shape single phase 50 Hz AC supply for Voltage stabilizer of Cap 0.5 to 5 KVA. Make AE, MIECO, Rishabh 10 Each
62 62 Supply only printer circuit control card suitable for 0.5 to 2 KVA 6 Each
63 63 Supply only printer circuit control card suitable for 3 KVA 6 Each
64 64 Supply only printer circuit control card suitable for 4 KVA to 5 KVA 7 Each
65 65 Supply only Input/output switch for Voltage stabilizer of Cap 0.5 to 5 KVA. Make AE/Rishabh/Mico 10 Each
66 66 Supply only Push on switch for Voltage stabilizer of Cap 0.5 to 5 KVA. Make AE/Rishabh/Mico 10 Each
67 67 Supply only Indicator complete with bulbs for Voltage stabilizer of Cap 0.5 to 5 KVA. Make Renutrol/Technomac 10 Each
68 68 Supply only Trigger Transformer for 0.5 KVA to 2 KVA voltage stabilizer. 10 Each
69 69 Supply only Trigger Transformer for 3 KVA to 5 KVA voltage stabilizer. 6 Each
70 70 Supply only Relay for 0.5 to 2 KVA voltage stablizer Make Renutorl/Technomac 6 Each
71 71 Supply only Relay for 3 to 5 KVA voltage stablizer Make Renutorl/Technomac 6 Each
72 72 Supply only Time delay and High/low voltage cut off circuit with relay suitable for 0.5 KVA to 2 KVA Make Renutorl/Technomac. 6 Each
73 73 Supply only Time delay and High/low voltage cut off circuit with relay suitable for 3 KVA to 5 KVA Make Renutorl/Technomac 6 Each
74 74 Taking out the burnt winding of transformer of voltage stablizer and prepairing core after cleaning by suitable cleaning agent and rewinding the transofrmer of voltage stablizer with super enameld copper wire of existing gauge including varnishing, heating and refiting of capacity 0.5 KVA voltage stablizer. 10 Each
75 75 Desctription all as per item No 73 above but for 1 KVA voltage stabilizer. 5 Each
76 76 Desctription all as per item No 73 above but for 2KVA voltage stabilizer. 6 Each
77 77 Desctription all as per item No 73 above but for 3 KVA voltage stabilizer. 6 Each
78 78 Desctription all as per item No 73 above but for 4 KVA voltage stabilizer. 6 Each
79 79 Desctription all as per item No 73 above but for 5 KVA voltage stabilizer. 6 Each
80 80 Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets etc removing materials for taking credit and making good disturbed surfaces of walls, floors, etc all as directed 15 Per Point
81 81 M&L point wiring complete with 2 run of 2.5 sqmm single core PVC insulated heavy duty ISI Marked , unsheathed cable 1100 volts grade with multistranded copper conductor drawn through andincluding suitable size of PVC white Casing and Caping with all accessories like tee, straight joint, L Bend etc., fixed to walls / roofs / floors / ceiling etc., and including provision of PVC insulated heavy duty ISI Marked unsheathed copper conductor 2.5 sqmm for earth continuity conductor and connected to common earth dolly, including suitable size of sheet metal box 1.6mm thick fixed and flushed inside the walls, with 3mm thick laminated sheet top cover for housing the switches/socket outlets, 15 Amps S/S outlet complete all as directed. 10 Per Point
82 82 Taking down for servicing of split type AC 1.5/2TR Capacity including cleaning of cooling coil, air filters/plasma filters etc., (Indoor unit), condenser, compressors, fan motor etc., (Out door unit) with vacuum cleaner OR cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit, fan, blower, etc., and keeping the AC unit in satisfactory working condition all as specified and as directed by Engineer-in-Charge. \n Note :- 1. Replacement of defective parts shall be measured & paid separately under relevant items as supply only and Labour charges for fixing of parts shall deem to be included in unit rate quoted. 60 Each Job
83 83 Taking down for servicing of Window type AC 1.5/2TR Capacity including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner OR cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit, fan, blower, etc., and keeping the AC unit in satisfactory working condition all as specified and as directed by Engineer-in-Charge.\nNote :- 1. Replacement of defective parts shall be measured & paid separately under relevant items and Labour charges for fixing of parts shall deem to be included in unit rate quoted. \n 60 Each Job
84 84 Supply only Running capacitor 36 MFD for Window/Split type AC unit of Cap 1.5 Ton/2 Ton Make : Bentex/Delcon 20 Each
85 85 Supply only Running capacitor 45 MFD for Window/Split type AC unit of Cap 1.5 Ton/2 Ton Make :- Unistar/Asian 25 Each
86 86 Supply onlyStarting capacitor 100-120 MFD for Window/Split type AC unit of Cap 1.5 Ton/2 TonMake:- Bentex/Delcon. 25 Each
87 87 Supply only Starting capacitor 120-150 MFD for Window/Split type AC unit of Cap 1.5 Ton/2 Ton Make :- Bentex/Delcon. 25 Each
88 88 Supply only Starting Relay 1022/ 1622 for Window/Split type AC unit of Cap 1.5 Ton/2 Ton Make :- Renutral/ Sri Ram/Micro Tech 30 Each
89 89 Supply only Starting Relay 2000 for Window/Split type AC unit of Cap 1.5 Ton/2 TonMake :- Renutral/Sri Ram/Micro Tech 25 Each
90 90 Supply only Thermostat switch 2059/2064/2054 for Window/Split type AC unit of Cap 1.5 Ton/2 TonMake :- Indfass. 15 Each
91 91 Supply only Lit lawn sheet 6mm thick and 1000 mm wide for Window/Split type AC unit of Cap 1.5 Ton/2 Ton 20 Each
92 92 Supply only Condenser fan blade for Window Type AC Cap 1.5/2 Ton made of Plastic. 10 Each
93 93 Supply only Condenser fan blade for split Type A.C Cap 1.5/2Ton made of Plastic. 10 Each
94 94 Supply only Copper filter double capillary pencil type for Window/Split type AC unit of Cap 1.5 Ton/2 Ton 10 Each
95 95 Supply only Thermocol sheet 40x20 inch and thickness 20mm for Window/Split type AC unit of Cap 1.5 Ton/2 Ton 10 Each
96 96 Supply only Wiring kit for A.C Windo/split Type 1.5/2 T 10 Each
97 97 Supply only Remote control for window type AC Cap 1.5/2 TR of any make as per site requirement. 8 Each
98 98 Supply only Remote control for split type AC Cap 1.5/2 TR of any make as per site requirement. 8 Each
99 99 Supply only Main printed circuit board (PCB) with electric accessories and sensors suitable for split type AC capacity 1.5/2 TR. 5 Each
100 100 Supply only Main printed circuit board (PCB) with electric accessories and sensors suitable for window type AC capacity 1.5/2 TR. 5 Each
101 101 Supply only Platic louvers for (Front panel) for Window AC 1.5/2 Ton as per existing at site. 5 Each
102 102 Supply only Selector switch for fan/cooling of Window type AC 1.5/2 Ton 5 Each
103 103 Supply only Suction and discharge valve set for Split type AC 1.5/2 TR capacity of any make as per exisiting 5 Each
104 104 Disconnecting from mains and Taking out existing unserviceable compressor sealed unit from the window type Air Conditioner of Cap 2 Ton, of any make any type from any location and Supply , Installing and testing of company made new sealed unit compressor with two years guarantee including cleaning and removing dust/dirt from the cooling coil condenser coil with necessary modification (caplary tube etc ) & Charging of Gas F-22/R-134A and commisioning as directed by Engr-in-Charge , Make :- Kirloskar /Tecumsha/Voltas/Carrier.\nNote :- Transportation Charges From site to trade workshop and back to original location after repair shall deem to be included in unit rate quoted. 8 Each Job
105 105 Description all as per item No. 104 above but Window Air Conditioner of Cap 1.5 Ton. 6 Each Job
106 106 Description all as per item No. 104 above but spilt type Air Conditioner of Cap. 2 Ton. 6 Each Job
107 107 Description all as per item No. 104 above but spilt type Air Conditioner Cap. 1.5 Ton. 6 Each Job
108 108 Disconnecting form mains and Taking out unserviceable fan motor/ blower motor of window type AC 1.5/2 ton capacity of any make and type from any location and supply, installing and testing new fan motor as per existing capacity and model all as directed by Egnr-in-charge Make : AUE/Crompton Greaves/Speed King/Cool Master\nNote :- Transportation Charges From site to trade workshop and back to original location after repair shall deem to be included in unit rate quoted. 6 Each Job
109 109 Description all as per item No 108 above but for split type AC 1.5/2 TR and ditto. 6 Each Job
110 110 Disconnecting form mains and Taking out unserviceable condenser coil of window Type AC Cap. 1.5 Ton/2 Ton of any make and type from any location and supply, installing and testing new condneser coil as per existing capacity and make as directed by Engr-in- Charge. Make Voltas/Carrier/LG\nNote :- Transportation Charges From site to trade workshop and back to original location after repair shall be deemed to be included in unit rate quoted. 6 Each Job
111 111 Description all as per item No 110 above but for split type AC 1.5/2 TR and ditto-- 5 Each Job
112 112 S & F in replacement of Evaporator /Cooling coil for window type AC Cap. 1.5 Ton /2 Ton Cap of existing make and size all as directed by Engr-in- Charge. 6 Each
113 113 Description all as per item No 112 above but for split type AC 1.5/2 TR and ditto-- 6 Each
114 114 Material & Labour one coat painting with synthetic enamel paint on the body of window type AC/Split type AC outer body unit capacity 1.5/2 TR of any make and capacity with colour as per existing at site including writing SM/MES No. on AC with paint complete all as specified and directed by Engineer-in- Charge. 6 Each
115 115 Taking down unserviceable outdoor unit of split type AC (only body) of existing make type 1.5/2 Ton capacity and supply & fixing new outdoor unit ( only body) suitable for existing 1.5 /2TR capacity Make LG/Carrier/Voltas 3 Each
116 116 Taking down unserviceable indoor unit ( Only body) of split type AC of existing make type and 1.5/2 Ton capacity and supply & fixing new indoor unit ( only body) suitable for existing 1.5/2TR capacity complete all as directaed by Engr-in-Charge Make LG/Carrier/Voltas 5 Each
117 117 Taking down unserviceable copper pipe of size 1/4" and supply & fixing new copper pipe 1/4" complete including brazing, welding, nut bolts and screws of reqd size complete all as directed by Engr-in-Charge 40 RM
118 118 Description all as per item No 117 above but size of copper pipe 5/8" 20 RM
119 119 Description all as per item No 117 above but size of copper pipe3/8" 20 RM
120 120 Description all as per item No 117 above but size of copper pipe 1/2" 20 RM
121 121 Material & labour for detecting the leakages of gas of window type AC capacity 1.5/2 TR from any location and rectified/stopped the leakages by gas welding or by any other means and make it functioning as directed by Engr-in-Charge 10 Each Job
122 122 Description all as per item No 121 above but for split type AC 1.5/2 TR and ditto- 10 Each Job
123 123 Charging only Refrigerant Gas F-22/R-134A in window type /Split Type AC Unit of capacity 1.5 /2Ton including testing and commissioning complete in satisfactory working condition as directed by Engineer-in-Charge. 10 Each Job
124 124 M&L point wiring complete with 2 run of 4.00 sqmm single core PVC insulated heavy duty ISI Marked , unsheathed cable 1100 volts grade with multistranded copper conductor drawn through andincluding suitable size of PVC white Casing and Caping with all accessories like tee, straight joint, L Bend etc., fixed to walls / roofs / floors / ceiling etc., and including provision of PVC insulated heavy duty ISI Marked unsheathed copper conductor 4.00 sqmm forearth continuity conductor and connected to common earth dolly for 20 Amps Metal clad socket complete all as specified and directed. 8 Per Point
125 125 Supply and Fix Metal clad socket outlet with single pole and nuetral enclosure with two pin and earth plug socket complete with one single pole MCB 20 Amps including taking down old/unsv Metal clad socket of any make complete all as specified and directed. 5 Each
126 126 Supply and fix MCB single pole, 240 volts, 5 to 40 Amps 10 KA complete including taking down old unservicable MCB of any type/capacity all as specified and as directed by Engr-in-Charge. 5 Each
127 127 Reversible valve suitable for refrigerant R-22 for 1.5/ 2.0/ 3.0 TR AC including copper pipe required at site Make -LG/ Carrier. 5 Each
128 128 Disconnecting from mains and Taking down for servicing of Water Cooler of Capacity 40 Ltrs including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner OR cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, fan and blower, etc. and keeping the Water cooler unit in satisfactory working condition all as specified and as directed by Engineer-in-Charge.\nNote :- 1. Replacement of defective parts shall be measured & paid separately under relevant items as supply only and Labour charges for fixing of parts shall deem to be included in unit rate quoted. 10 Each Job
129 129 Description all as per item No 128 above but for water cooler 150 ltrs capacity and ditto. 10 Each Job
130 130 Supply only Over load protector device for 150 Ltr Cap. Water Cooler Make: Sri Ram, Renutrol/Micro Tech 10 Each
131 131 Supply only Over load protect device for 40 Lts Cap. Water cooler Make: Sri Ram, Renutrol/Micro Tech 10 Each
132 132 Supply only Starting relay open type/Box type suitable for 150 Ltr Make: Sri Ram, Renutrol/Micro Tech 10 Each
133 133 Supply only Starting relay open type/Box type suitable for 40 Ltr water cooler Make: - Sri Ram, Renutrol/Micro Tech 10 Each
134 134 Supply only Starting Capacitor 36 MFD for water cooler 40/150 ltr capacity Make : Unistar/Bentex 10 Each
135 135 Supply only Starting Capacitor 80-100 MFD for water cooler 40/150 ltr capacity Make : Unistar/Bentex 10 Each
136 136 Supply only Running Capacitor 25 MFD for water cooler 40/150 ltr capacity Make: Unistar/Bentax. 10 Each
137 137 Supply only Drain Hose pipe 40mm for water cooler 40/150 ltr capacity. 5 RM
138 138 Supply only Condenser fan blade plastic for fan Motorn 1/10/ 1/16 HP for water cooler 40/150 ltr capacity. 7 Each
139 139 Supply only Condenser fan blade plastic for Motor 1/32, 1/35 for water cooler 40/150 ltr capacity. 8 Each
140 140 Supply only Copper filter pencil type single / Double Capillary for water cooler 40/150 ltr capacity. 8 Each
141 141 Supply only Self closing/pushtaps for water cooler Cap 150/40 Ltr for water cooler 40/150 ltr capacity. 8 Each
142 142 Supply only R-22 refrigerant gas. 30 Kg
143 143 Supply only R-134 refrigerant gas. 25 Kg
144 144 Taking down the window type AC of any capacity from existing location and shifting & installation at another location after cleaning coil & greasing etc. for satisfactory working as directed by Engr-In -Charge. 5 Each Job
145 145 Taking down the split type AC of any capacity from existing location and shifting & installation at another location after cleaning coil & greasing etc. for satisfactory working as directed by Engr-In -Charge. 5 Each Job
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail