Military Engineer Services-MES has published Special Repair Replacement Of Ac Sheet Incl Other Misc Work In T 72 Bay Svg Clr Bay P 74 Teg Bldg Wire Mesh Glass Fitted Near Roof Of Bldg No 139 And Bay No 2 And 3 Of P 74 Of Abw Area Under Ge North Delhi Cantt 10. Submission Date for this Tender is 25-06-2020. Roofing Materials Tenders in Delhi Cantt Delhi. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 09-Jun-2020 | Amendment | BOQ | 18-06-2020 |
2 | 18-Jun-2020 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 25-06-2020 |
Name of Work : SPL REPAIR/ REPLACEMENT OF AC SHEET INCL OTHER MISC WORK IN T-72 BAY, SVG/CLR BAY (P-74), TEG BLDG, WIRE MESH GLASS FITTED NEAR ROOF OF BLDG NO-139 & BAY NO 2& 3 OF P-74 OF ABW AREA UNDER GE (NORTH) DELHI CANTT-10. | |||||
---|---|---|---|---|---|
Sch. item No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Dismantling of Plain or corrugated steel/ fibre sheeting of any guage as in roof covering including ridges/gutters etc of any description straight or curved at height upto 15 mtr complete all as specified and directed. | 2088 | Sqm | |
2 | 2 | Hacking out old broken glass (any thickness, size , quality or description) from metal frame including punching or drilling out old glazing pins/ spring clips, nut bolts & fillets at ht upto 15 mtr complete all as specified and directed. | 820 | Sqm | |
3 | 3 | Dismantling of AC sheet roof corrugated/semi corrugated of any description including ridges/gutters etc at height upto 15 mtr complete all as specified and directed. | 5664 | Sqm | |
4 | 4 | Dismantling wrought iron or mild steel work of any description not otherwise provided for . | 21 | Qtl | |
5 | 5 | Demolition of Brickwork or stone/ boulders masonry built in cement or cement lime mortar incl all quions, arches, pillars, etc but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified and directed. | 14 | Cum | |
6 | 6 | Material and labour for Brick work with sub class B bricks of old size, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 complete all as specified and directed. | 10 | Cum | |
7 | 7 | All as item above here-in-before but except bricks complete all as specified and directed. | 4 | Cum | |
8 | 8 | M&L for Pre-painted galvalume aluminum zinc coating @ 150 gsm, GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws at height upto 15 mtr complete all as specified and directed. Note: 1. The rates quoted shall include cost of necessary steel scaffolding & safety apparatus.\n2. The sheets shall be procured directly from manufacturer.\n3. The galvalume sheets shall be covered with filmguard. | 5664 | Sqm | |
9 | 9 | M&L for Pre-painted galvalume aluminum zinc coating @150 gsm GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws at height upto 15 mtr complete all as specified and directed.\nNote: 1. The rates quoted shall include cost of necessary steel scaffolding & safety apparatus.\n2. The sheets shall be procured directly from manufacturer.\n | 40 | Sqm | |
10 | 10 | S&F 2mm thick PGI Sheet having 275 gsm zinc coating (both side) as in gutter dripper straight flushing with 100mm overlap made to required shape as rain water pipe of 250mm dia incl welding or revetting and fixed in position at ht upto 15 mtr all as specified and directed.\nNote: 1. The rates quoted shall include cost of necessary steel scaffolding & safety apparatus.\n2. The sheets shall be procured directly from manufacturer. | 1240 | Sqm | |
11 | 11 | S&F 0.80 mm thick PGI sheet as in ridges, hips valley gutters drip and straight, flashing etc having 275 gm of zinc coating per sqm (both side inclusive) fixed with L or J hook or cranked hook bolts up to 15 mtr hight complete all as specified and directed.\nNote: 1. The rates quoted shall include cost of necessary steel scaffolding & safety apparatus.\n2. The sheets shall be procured directly from manufacturer. | 808 | Sqm | |
12 | 12 | S&F for MS work in Bands, straps, supports or stays for RWP, ventilating pipes, gutters including bolts, if reqd hooks (stay), clamps, holdfasts, wall ties, nosing angles, hooks for hanging fans and similar small articles conforming to Fe-290 gde E-165 hight up to 15 mtrs | 2180 | Kg | |
13 | 13 | S&F structural steel work for rolled sections as in main and cross beams, hips and jack rafters, purlins, running rails and guides for sliding doors, fixed with angle cleats or other connecting plates gde Fe-410-Wat any height complete all as spd and directed. | 5915 | Kg | |
14 | 14 | S&F in repair for Gypsum ceiling board for prepainted ceiling, perforated finish, 600 x 600 x 9 to 9.5mm thick in size, of approved brand/make, laid over and including grid work of size 600 x 600mm, made out of 0.5mm thick G.I. tee 32 x 24 mm for main, 25x24mm for cross tee and 20 x 20mm angle fixed on wall, 75 micron thick powder coated, hung from ceiling using 2 mm thick G.I. Suspension wires spaced at 1200 mm on main runners including making niches for fans/light at as specified and directed. | 114.5 | Sqm | |
15 | 15 | S&F Rough cast, wired glass exc 6.00 mm thick but n.exc 6.40 mm thick fixed with Flat Iron and nut bolts in square exc. 0.75 Sqm but n.exc 01 sqm in each pane at ht upto 15 mtr complete all as specified and directed. | 756 | Sqm | |
16 | 16 | S&F sheet glass ordinary quality, 3 mm thick and glazing with oil putty in square n.exc. 0.5 Sqm in each pane at ht upto 15 mtr complete all as specified and directed. | 64 | Sqm | |
17 | 17 | S&F in repair steel rolling shutters, without ball bearing as specified including top covers anchoring rod, hasp & staple and one shop coat of red oxide primer gear operated type with bevel gear box and crank handle and errected in position complete thickness of laths 1.25mm complete all as specified and directed.The span of rolling shautter shall be not less than 3.0 Mtr. each | 147 | Sqm | |
18 | 18 | M&L for preparation of newly steel surfaces and applyng two coats of aluminium paint over a coat of red oxide (Red oxide coat done on manufacturing shop) complete all as specified and directed. | 330 | Sqm | |
19 | 19 | M&L for preparation of newly steel surfaces and applyng two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed. | 120 | Sqm | |
20 | 20 | M&L Roughening surfaces of old concrete surfaces by picking sweeping, cleaning and washing down with water to remove dust etc including taking down tarfelt and brushing neat cement slurry @ 3 Kg/Sqm complete all as specified and directed. | 1010 | Sqm | |
21 | 21 | M&L providing 1:2:4 type B-0 cement concrete in roof padding for maintain the roof slope etc and other similar works all as directed. | 38 | Cum | |
22 | 22 | M&L for laying APP polymer modified approved membrance, non woven, polyester, weighing not less than 3.5 Kg/Sqm with laps & overlaps as specified & joints sealed and applied complete by torch application method over prepared roof slab, chajjas etc, by brooming with broom sweeping free from dirt dust etc & evenly applying a coat of approved bituminous primer @ 0.20 Kg/Sqm of area over and including 15 mm thick plaster screed bed layer in CM 1:3 on concrete surface finished even and smooth mixed with water proofing compound (WPC shall be measured and paid separate). Finally applying a coat of solar reflective bituminous aluminium paint @ 0.15 ltr/Sqm on the top of membrane surfaces complete all as specified & directed by Engineer-in-Charge. | 1010 | Sqm | |
23 | 23 | Taking down cement plaster of any description & thickness from brick/concrete sufaces of wall/ceiling etc including racking out joints, hacking for keys scrubbing down with water etc. complete all as specified and directed. | 575 | Sqm | |
24 | 24 | M&L rendering 15mm thick in cement mortar (1:4)on fair faces of brickwork/concrete surfaces complete all as specified and directed. | 300 | Sqm | |
25 | 25 | M&L rendering 15mm thick in cement mortar (1:6)on fair faces of brickwork/concrete surfaces complete all as specified and directed. | 200 | Sqm | |
26 | 26 | M&L rendering 10mm thick cement plaster in cement mortor (1:4) on concrete surfaces of ceiling complete all as specified and directed. | 75 | Sqm | |
27 | 27 | M&L preparation of new plastered surface of walls and applying two coats of oil bound distemper over a coat ofchalk whiting complete all as specified and directed. | 200 | Sqm | |
28 | 28 | M&L for complete removal of existing treatment from old surface of wall complete all as directed | 650 | Sqm | |
29 | 29 | M&L 3mm thick wall care putty on internal surfaces of wall for making the old surface even and smooth complete all as specified and directed. | 530 | Sqm | |
30 | 30 | M&L for applying two coats of oil bound distemper on wall including preparation the surface of complete all as specified and directed. | 530 | Sqm | |
31 | 31 | M&L preparation of old surface by scrubbing down existing treatment on walls and applying two coats of cement base paint complete all as specified and directed. | 120 | Sqm | |
32 | 32 | M&L preparation of old decorated surfaces of ceiling plastered or unplastered) by brooming down scrapping down smoke and efflorescent salts etc and applying one coat of white wash on ceiling complete all as specified and directed. | 160 | Sqm | |
33 | 33 | M&L preparation of newly plastered surface of walls and applying two coats of cement base paint complete all as specified and directed. | 300 | Sqm | |
34 | 34 | M&L preparation of newly plastered surface of ceiling and applying two coats of white wash complete all as specified and directed. | 75 | Sqm | |
35 | 35 | Removal of plants/trees of girth n exe 30 cm from roof tops/sides, external walls of bldg, chajjas, wall junctions, junctions of rain water/CI soil/waste pipe junctions including taking out the roots entered in wall/slab surfaces and making good the disturbed surfaced using PCC (1:2:4) type B-0 or cement mortar (1:2) including repairing the GI/CI/PVc pipe joints which were damged during cutting/taking out process to match with the existing material and finishing the disturb surfaces to match with existing including necessary steel scaffolding/staging upto a height of 15.00 m from the ground level complete all as specified as directed.\nNote: For deciding the girth of the plant/tree the height shall be taken at 30 cm above the slab/wall.\n\n | 22 | Each | |
36 | 36 | Supply only integral water proofing compound complete all as specified as directed. | 37 | Kg |