| 1 | 1 | Supply, install, testing and commissiong in replacement of indoor LT main panel totally enclosed weather and vermin proof, suitable verntilated, 440 Volts, 50 HZ, AC supply, factory made out of 3 mm thick CRCA sheet steel for load bearing and 2.0 mm thick non load bearing portions, protection of enclosure IP-54 complete with pretreatment and powder coating of approved colour including suitable angle iron/flat iron frame work supports, excavation and earth work, PCC foundation etc,necessary electrical connections with exisinting cable with new double compressed cable glands of required size of cables, cubical type as required with and including the following, supplied fitted and connected internally complete all as specifed and as directed :- \n(a) 04 Nos aluminium bus bar of unequal size of aluminium conductor with PVC coloured heat srinkable type sleeves continous phase rating 600 Amps and neutral rating 300 Amps mounted on non cracting resin type insulators with CTs digital type, ammeter and volt meter with selector switches, set of LED type indicating lamps R, Y, B on incoming side (Makes of Panel bds are as approved by E-in-Cs, New Delhi and CPRI approved)\n(b) MCCB 4 pole 400Amp. 36KA thermal magnetic fixed type - 01 No (Incoming) \n(c) MCCB 4 pole 200Amp. 25KA thermal magnetic fixed type - 01 No (Outgoing) \n(d) MCCB 4 pole 63Amp. 16KA thermal magnetic fixed type - 01 No (Outgoing) \n(e) MCCB 4 pole 125Amp. 16KA thermal magnetic fixed type - 02 No (Outgoing) | | 1 | Each job |
|---|
| 2 | 2 | Supply, install, testing and commissiong in replacement of indoor LT main panel totally enclosed weather and vermin proof, suitable verntilated, 440 Volts, 50 HZ, AC supply, factory made out of 3 mm thick CRCA sheet steel for load bearing and 2.0 mm thick non load bearing portions, protection of enclosure IP-54 complete with pretreatment and powder coating of approved colour including suitable angle iron/flat iron frame work supports, excavation and earth work, PCC foundation etc,necessary electrical connections with exisinting cable with new double compressed cable glands of required size of cables, cubical type as required with and including the following, supplied fitted and connected internally complete all as specifed and as directed :- \n(a) 04 Nos aluminium bus bar of unequal size of aluminium conductor with PVC coloured heat srinkable type sleeves continous phase rating 600 Amps and neutral rating 300 Amps mounted on non cracting resin type insulators with CTs digital type, ammeter and volt meter with selector switches, set of LED type indicating lamps R, Y, B on incoming side.\n(b) MCCB 4 pole 400Amp. 36KA thermal magnetic fixed type - 01 No (Incoming) \n(c) MCCB 4 pole 315Amp. 36KA thermal magnetic fixed type - 01 No (Outgoing) \n(d) MCCB 4 pole 250Amp. 25KA thermal magnetic fixed type - 03 No (Outgoing) | | 1 | Each job |
|---|
| 3 | 3 | Supply, install, testing and commissiong in replacement of indoor LT main panel totally enclosed weather and vermin proof, suitable verntilated, 440 Volts, 50 HZ, AC supply, factory made out of 3 mm thick CRCA sheet steel for load bearing and 2.0 mm thick non load bearing portions, protection of enclosure IP-54 complete with pretreatment and powder coating of approved colour including suitable angle iron/flat iron frame work supports, excavation and earth work, PCC foundation etc,necessary electrical connections with exisinting cable with new double compressed cable glands of required size of cables, cubical type as required with and including the following, supplied fitted and connected internally complete all as specifed and as directed :- \n(a) 04 Nos aluminium bus bar of unequal size of aluminium conductor with PVC coloured heat srinkable type sleeves continous phase rating 300 Amps and neutral rating 200 Amps mounted on non cracting resin type insulators with CTs digital type, ammeter and volt meter with selector switches, set of LED type indicating lamps R, Y, B on incoming side internally prewired (Makes of Panel bds are as approved by E-in-Chiefs, New Delhi and CPRI approved).\n(b) MCCB 4 pole 250Amp. 25KA thermal magnetic fixed type - 01 N+B9o (incoming) \n(c) MCCB 4 pole 200Amp. 25KA thermal magnetic fixed type - 01 No (Outgoing) \n(d) MCCB 4 pole 160Amp. 16KA thermal magnetic fixed type - 01 No (incoming) \n(e) MCCB 4 pole 100Amp. 16KA thermal magnetic fixed type - 01 No (Outgoing) | | 2 | Each job |
|---|
| 4 | 4 | Supply, install, testing and commissiong in replacement of indoor LT main panel totally enclosed weather and vermin proof, suitable verntilated, 440 Volts, 50 HZ, AC supply, factory made out of 3 mm thick CRCA sheet steel for load bearing and 2.0 mm thick non load bearing portions, protection of enclosure IP-54 complete with pretreatment and powder coating of approved colour including suitable angle iron/flat iron frame work supports, excavation and earth work, PCC foundation etc,necessary electrical connections with exisinting cable with new double compressed cable glands of required size of cables, cubical type as required with and including the following, supplied fitted and connected internally complete all as specifed and as directed :- \n(a) 04 Nos aluminium bus bar of unequal size of aluminium conductor with PVC coloured heat srinkable type sleeves continous phase rating 200 Amps and neutral rating 150 Amps mounted on non cracting resin type insulators with CTs digital type, ammeter and volt meter with selector switches, set of LED type indicating lamps R, Y, B on incoming side (Makes of Panel bds are as approved by E-in-Chiefs, New Delhi and CPRI approved)\n(b) MCCB 4 pole 160Amp.25KA thermal magnetic fixed type - 01 No (Incoming)\n(c) MCCB 4 pole 63Amp. 16KA thermal magnetic fixed type - 04 No (Outgoing) | | 3 | Each job |
|---|
| 5 | 5 | Supply, install, testing and commissiong in replacement of indoor LT main panel totally enclosed weather and vermin proof, suitable verntilated, 440 Volts, 50 HZ, AC supply, factory made out of 3 mm thick CRCA sheet steel for load bearing and 2.0 mm thick non load bearing portions, protection of enclosure IP-54 complete with pretreatment and powder coating of approved colour including suitable angle iron/flat iron frame work supports, excavation and earth work, PCC foundation etc,necessary electrical connections with exisinting cable with new double compressed cable glands of required size of cables, cubical type as required with and including the following, supplied fitted and connected internally complete all as specifed and as directed :- \n(a) 04 Nos aluminium bus bar of unequal size of aluminium conductor with PVC coloured heat srinkable type sleeves continous phase rating 800Amps and neutral rating 400Amps mounted on non cracting resin type insulators with CTs digital type, ammeter and volt meter with selector switches, set of LED type indicating lamps R, Y, B on incoming side (Makes of Panel bds are as approved by E-in-Chiefs, New Delhi and CPRI approved)\n(b) MCCB 4 pole 630Amp. 36KA thermal magnetic fixed type - 01 No (Incoming) \n(c) MCCB 4 pole 250Amp. 25KA thermal magnetic fixed type - 03 No (Outgoing) \n(d) MCCB 4 pole 125Amp. 16KA thermal magnetic fixed type - 02 No (Outgoing) \n(e) MCCB 4 pole 63Amp. 16KA thermal magnetic fixed type - 01 No (Outgoing) | | 1 | Each job |
|---|
| 6 | 6 | Supply, install, testing and commissiong in replacement of outdoor LT Feeder pillar box totally enclosed weather and vermin proof, suitable verntilated, 440 Volts, 50 HZ, AC supply, factory made out of 2 mm thick CRCA sheet steel for load bearing protection of enclosure IP-54 complete hinged door with pretreatment and powder coating of approved colour including suitable angle iron/flat iron frame work supports, excavation and earth work, PCC foundation etc, cubical type as required with and including the following, supplied fitted and connected internally complete, 04 Nos aluminium bus bar of unequal size of aluminium conductor with PVC coloured heat srinkable type sleeves continous phase rating 300 Amps and neutral rating 200 Amps mounted on non cracting resin type insulators complete all as specified and as directed. | | 4 | Each job |
|---|
| 7 | 7 | S&F in replacemtn of MCCB adjustable thermal and adjustable magnetic settings (L Frame) alongwith extended terminals complete AC 415 V, 50 Hz of cap 250 Amps 25KA complete alongwith necessary electrical connections and by using new lugs and terminations and complete all as specified and as directed. | | 4 | Each |
|---|
| 8 | 8 | S&F in replacement of MCCB adjustable thermal and adjustable magnetic settings (L Frame) alongwith extended terminals complete AC 415 V, 50 Hz of cap 200 Amps 26KA complete alongwith necessary electrical connections and by using new lugs and terminations complete all as specified and as directed. | | 5 | Each |
|---|
| 9 | 9 | S&F in replacement of MCCB adjustable thermal and adjustable magnetic settings (L Frame) alongwith extended terminals complete AC 415 V, 50 Hz of cap 63 Amps 16KA complete alongwith necessary electrical connections and by using new lugs and terminations complete all as specified and as directed. | | 6 | Each |
|---|
| 10 | 10 | S&F in repairs PVC conduit pipe 20mm dia with fixing arrangement with flat iron with nut bolts on pole complete all as specified and as directed. | | 100 | RM |
|---|
| 11 | 11 | Supply and laying synthetic insulating mat of size 2.0mx1.0mx19mm complete at the substations and other installations by remvoing and disposal of wornout mats complete all as specified and as directed. | | 16 | Each |
|---|
| 12 | 12 | S&F in replacement of PVC cable aluminium stranded conductor 1100V grade 10sqmm, 2.0core complete all as specified and as directed.\nMake : Polycab/Havells/Finolex | | 400 | RM |
|---|
| 13 | 13 | Cleang surfaces of installation/sub station area by removing of grass etc. from the roof of building, in fencing and surrounding area of installation building complete all as specified and as directed. | | 800 | Sqm |
|---|
| 14 | 14 | M&L in replacement of earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground preferably vertically in ground with top edge not less than 1.25 mtr deep below normal ground level connected with and including galvanised iron 32x6mm as earthing lead by means of nuts bolts and washers of galvanized iron protected by 15mm dia (medium grade) GI tubing, funnel, wire mesh, 20mm bore GI tubing (light grade) watering pipe , including concrete pit in PCC (1:3:6) type C-1, precast RCC (1:2:4) type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT bars @ 15cm c/c in both ways and 10mm dia MS handle (01 No) of suitable size, charcoal and salt in alternate layers necessary excavation and earth work in soft/loose soil all as shown in electrical plate No. 2 of SSR part-I and testing on completion complete all as specified and as directed. | | 18 | Each Set |
|---|
| 15 | 15 | M&L Earthing complete with GI earth plate electrode 600mmx 600mmx6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers protected by 15mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers,necessary earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing complete inclduing taking down old one/ dismantling complete all as specified and as directed. | | 2 | Each Set |
|---|
| 16 | 16 | M&L in replacement , Danger notice plate of 1.6mm thickmild steel sheet, vitreous enamelledwhite, with letters, figures andconventional skull and bones insignal red colour and fixed with M.S. clamps, bolts and nuts ofapproved size, for LT, 20x15 cm size complete all as specified and as directed. | | 40 | Each |
|---|
| 17 | 17 | S&F in replacement precast RCC cable route indicator duly marked/grouted and painted for HT/LT cable of size 60x25x7.5cm with suitable size of 6mm dia reinforcement 1.0 Kg in Each complete all as specified and as directed. | | 30 | Each |
|---|
| 18 | 18 | Preparing external/internal surfaces of the panel boards/feeder pillar boxes, consoles etc. by scrubbing/CTC by emary paper by removing stains/rusted scales etc. and applying two coats of synthetic enamel paint over a coat red oxide primer complete and cleaning the meters/indicators/MES Nos, making good complete etc complete all as specified and as directed. | | 120 | Sqm |
|---|
| 19 | 19 | Supply and laying of cable UG XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 4.00 Sqmm 2 core including taking out old one complete all as specified and directed. | | 165 | RM |
|---|
| 20 | 20 | Supply and laying of cable UG XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 6.00 Sqmm 2 core including taking out old one complete all as specified and directed. | | 116 | RM |
|---|
| 21 | 21 | Supply and laying of cable UG XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10.00 Sqmm 2 core including taking out old one complete all as specified and directed. | | 142 | RM |
|---|
| 22 | 22 | Supply and laying of cable UG XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16.00 Sqmm 4 core including taking out old one complete all as specified and directed. | | 40 | RM |
|---|
| 23 | 23 | Supply and laying of cable UG XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 70.00 Sqmm 3.5 core including taking out old one complete all as specified and directed. \n(Note: Excavation and earth work shall be measured and paid seperately) | | 142 | RM |
|---|
| 24 | 24 | Excavation in trenches exceeding 1.5 m wide and not exceeding 1.5 m depth for foundation of poles etc not exc 10 Sqm in plan and getting out in soft /loose soil complete all as specified and as directed. | | 147 | Cum |
|---|
| 25 | 25 | Excavation in trenches exceeding 1.5 mtr wide and not exceeding 3 mtr depth (beyond the first 1.5 Meter ) for foundation of poles etc not exc 10 Sqm in plan and getting out in soft /loose soil complete all as specified and as directed. | | 1 | Cum |
|---|
| 26 | 26 | Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed. | | 91 | Cum |
|---|
| 27 | 27 | Removing excavated materials not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point to a distance not exceeding 50 mtrs and depositing where directed to a level not exceeding 1.5 mtr above the starting point all as specified and as directed. | | 57 | Cum |
|---|
| 28 | 28 | M&L for sand cushioning and covering with clean dry sand in trenches for protection of under ground cables (below, above and around the table laid in trenches ) complete all as specified and as directed. | | 48 | CUM |
|---|
| 29 | 29 | Supply and laying well burnt bricks sub class B bricks laid for cable protection with length of brick perpendicular to length of cable complete all as specified and as directed. | | 3.7 | Per 1000 Nos |
|---|
| 30 | 30 | S&F for vertical distribution board multiphase outgoing suitable to mount MCCB 63 A, 4 pole as incoming 4way double door with MCB SP 6-32 A as out going complete all as specified and as directed. \nNote : MCB SP and MCCB shall be measured and paid separately under relavent items) | | 1 | Each |
|---|
| 31 | 31 | S&F for MCCB 4 pole 63 A, 16KA, thermal magnetic fixed type complete all as specified and as directed | | 1 | Each |
|---|
| 32 | 32 | S&F for MCB 'C' series SP 6 to 32 Amps, 240 volts, breaking capacity 10KA, cat no. 4086 09-17 of Legrand complete all as specified and as directed.\n | | 18 | Each |
|---|
| 33 | 33 | S&F for MCB 'C' curve Single pole & Neutral 6 to 32 Amps with breaking capacity 10 KA, Cat No. 408609-17 of Legrand complete all as specified and as directed.\n | | 1 | Each |
|---|
| 34 | 34 | S&F in replacement of sheet metal enclosure for MCB DB double door single pole and Neutral 8 way, 240 V with common bus bar at incomming end complete all as specified and as directed. | | 1 | Each |
|---|
| 35 | 35 | M&L for 2 runs of cable PVC insulated but unsheathed 4.0Sqmm, stranded copper conductor in and including PVC caping & casing with continuous earthing cable PVC insulated 4.0 Sq mm, stranded copper conductor all as specified and as directed. \nMake : Anchor/Finolex/RR Kabel | | 42 | RM |
|---|
| 36 | 36 | S&F for LED bollard light with integral driver 9 watts cap cylindrical with unifor light distribution , IP65 including necessary fixing accessories like nuts& bolts for holding the fitting in & incl to be fixed with nuts and bolts by grouting the bolts in PCC including PVC bend of size 50mm to be provided PCC base with flush metal box embedded for passing/termination of the cables and suitable connector to be provided for incoming and outgoing of UG cable passing through each fitting and connecting the luminaries with twin core aluminium cable complete all as specified and as directed. \nMake : C&S MUSCA9W/Havells/Crompton/Jaquar. | | 17 | Each |
|---|
| 37 | 37 | S&F in replacement of SMC Enclosure 350x 250x150mm inner size including terminal conector fixed inside with due supports with MCB SPN control over din-rail of cap 32 A with necessary clamps, bolts/nuts fixed to MS Channel support duly grouted on PCC embedded complete all as specified and as dirtected.\nMake : Syntex/Hensel | | 1 | Each |
|---|
| 38 | 38 | M&L for plain cement concrete (1:2:4) type B-1 (with using 20 mm graded stone aggregate) as in coping necessary form work and finishing the exposed plaster in cement mortar (1:3), 5mm thick and finished even and smooth without using extra cement complete all as specifed and as directed. | | 1 | Cum |
|---|
| 39 | 39 | M&L for plain cement concrete 1:3:6 type C2 (using 40mm gradede stone aggregate ) as in foundation filling and mass concrete etc complete all as specified and as directed. | | 2 | Each |
|---|
| 40 | 40 | M&L for Weather proof flat twin core cable of 2.5Sqmm for connecting of light fittings complete all specified and as diredcted. | | 105 | RM |
|---|
| 41 | 41 | S&F for galvanized steel tubing 32mm bore, light grade, with fittings and MS clamps nut, bolts etc. for cable protection on pole, road crossing or ground in pillar for fixing light etc complete all as specified and as directed. | | 3 | RM |
|---|
| 42 | 42 | S&F for galvanized steel tubing 40mm bore, light grade, with fittings and MS clamps nut, bolts etc. for cable protection on pole, road crossing or ground in pillar for fixing light etc complete all as specified and as directed. | | 2 | RM |
|---|
| 43 | 43 | Taking down carefully copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants , regulators, sockets light fitting etc for taking credit removing from site and making good disturbed surface of walls, floors etc complete all as specified and as directed. | | 69 | Point |
|---|
| 44 | 44 | M&L for concealed point wiring with 1.5 sq mm (nominal area) single core pvc insulated FR unsheathed multi-standared copper conductor cable (maintaining colour code) , 1100 volt grade and including pvc conduitct (size as required site) concealed and sunken terminal boxes with 3 mm hylam sheet top cover of adequate size for mounting switches , sockets , regulators light fitting etc complete with all fitting and accessories fixed to wall /ceiling for one light /fan/call bell point concealed by one switch including one run 1.5 sq mm (nominal area) PVC insulated frame retardant unsheathed multistranded copper conductor cable green in colour for earth continuity conductor connected to common earth point duly completed all as specified and as directed. | | 51 | Point |
|---|
| 45 | 45 | All as per item No. 44 above but on 5 amp 3/5 pin socket outlet on independent board complete all as specified and as directed. | | 10 | Point |
|---|
| 46 | 46 | All as per item No 44 above but on 5 amp 3/5 pin socket outlet point on same board with other switches complete all as specified and as directed. | | 3 | Point |
|---|
| 47 | 47 | All as per item No.44 here in before but wiring with cables of size 2.5 sqmm for wiring & cables of size 2.5 sqmm both as continuous earth wire for one 15 Amps, 3 pin Switch/Socket outlet on Independent board complete all as specified and as directed. | | 5 | Point |
|---|
| 48 | 48 | S&F for switch piano, flush type single pole, one way 5 Amp complete all as specified and as directed. | | 54 | Each |
|---|
| 49 | 49 | S&F for socket outlet 2 in 1, 5 Amp flush type complete all as specified and as directed. | | 3 | Each |
|---|
| 50 | 50 | S&F for switch socket combination 2 in 1, 5 Amp flush type complete all as specified and as directed. | | 10 | Each |
|---|
| 51 | 51 | S&F for switch socket combination 5A/ 16A, 5 in 1flush type complete all as specified and as directed. | | 5 | Each |
|---|
| 52 | 52 | S&F for ceiling rose, 3 way PVC insulated body complete all as specified and as directed. | | 39 | Each |
|---|
| 53 | 53 | S&F for stepped type electronic fan regulator flush type complete all as specified and as directed. | | 5 | Each |
|---|
| 54 | 54 | S&F for 18 W surface and wall mounted LED Batten with polycarbonate housing and intigrated complete all as specified and as directed.. \nMake : Cat No LUMILINEBS18WLED865SPCWH of Havells/Philips/Bajaj/CG/Wipro | | 20 | Each |
|---|
| 55 | 55 | S&F for 25 W LED building security new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminum housing with hight power LED as lighting source and lens imbedded PC Cover having top opening seperate driver cmpartment with IP 65 protection and inpact resistance of IK07 complete all as specified and as directed. \nMake : Cat No. ENDURAPEARLSL25WLED757SASYTOPC of Havells/Philips/Bajaj/ CG/Wipro | | 8 | Each |
|---|
| 56 | 56 | S&F for LED street light fitting of capacity 100W, with pressure die cast housing , toughned glass and individual LEDs with secondary optics and IP 66 protection, including with necessary brackets /pipes/clamps & nuts& bolts for holding the street light fitting with necessary electrical connections required in existing location.\nMake : Cat No. Endura cityliner Neo SL 100W LED757SASYBOTG of Havells/ Everyday/ Jaquar/Phillips (Warrenty on Driver, LEDs and PCB for 5 Years to be submitted by the contractor) (Necessary excavation, PCC wk, Bracket, Connecting wire will be measured and paid separately under relavent items) | | 8 | Each |
|---|
| 57 | 57 | S&F for LED street light fitting of capacity 80W, with pressure die cast housing , toughned glass and individual LEDs with secondary optics and IP 66 protection, including with necessary brackets /pipes/clamps & nuts& bolts for holding the street light fitting and twin core aluminum cable of 2.5 Sqmm as required in existing location.\nMake : Cat No. Endura pearl plus SL80WLED757SASYTOPC of Havells/ Everyday/ Jaquar/Crompton (Warrenty on Driver, LEDs and PCB for 5 Years to be submitted by the contractor)(Necessary excavation, PCC wk, Bracket, Connecting wire will be measured and paid separately under relavent items) | | 20 | Each |
|---|
| 58 | 58 | S&F for exhaust fans AC single phase 230/ 240 V of size 380 mm sweep 1 phase 1400 RPM complete all as specified and as directed.\nMake : Crompton/Bajaj/Havells | | 6 | Each |
|---|
| 59 | 59 | S&F for lamp holder, PVC/Polycarbonate type with back plate suitable for batten fitting complete all as specified and as directed. | | 12 | Each |
|---|
| 60 | 60 | S&F for LED Bulb of 09 Watt complete all as specified and as directed. | | 12 | Each |
|---|
| 61 | 61 | S&F for street light bracket arm of length not less than 1.5 Mtr made out of GI tubing 32mm light grade fixed to pole etc with suitable size flat iron clamp nuts, bolts complete all as specified and as directed. | | 28 | Each |
|---|
| 62 | 62 | S&F for PVC junction box/loop in and out box, out door type,door duly hinged and opeanble type IP-65 with busbar and din rail to accommodate MCB SP 0f 6 Amps 'B\" Series complete all as specified and directed.\nMake - Hansel/ Sintex | | 2 | Each |
|---|
| 63 | 63 | S&F for PVC insulated copper conductor multi stranded passing through the exisitng hollow pipe of steel tubular pole with 3 runs of cable of size 2.5 Sqmm sheathed complete all as specified and as directed. | | 45 | RM |
|---|
| 64 | 64 | M&L for steel tubular swaged poles complete with cast iron base plate final taper plug bolts nuts & screws as specified 410 SP-31 (9.0 meter long) including two coats of aluminium paint over a coat of primer except the planing depth which shall be apinted with black bituminious paint including writing pole number using suitable paint complete all as specified and as directed.\nNote : Excavation and earth work, PCC filling shall be measured and paid separatley. | | 2 | Each |
|---|