Irrigation And Public Health Department has published Providing Sewerage With Sewerage Treatment Plant In Trilokpur Sada Area In Tehsil Nahan Distt . Sirmour Supply And Errection Of Pumping Machinery , D/System , Soft Starter , Rcc Ohsr , R/Main And Pump House For Drinking Water Supply Scheme. Submission Date for this Tender is 15-06-2020. Pump Supply Tenders in Nahan Himachal Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 30-May-2020 | Corrigendum | Other | 08-06-2020 |
2 | 06-Jun-2020 | Corrigendum | Date | 15-06-2020 |
3 | 09-Jun-2020 | Office Order | Other | 15-06-2020 |
Name of work:- Providing Sewerage with sewerage treatment plant in Trilokpur SADA area in Tehsil Nahan Distt. Sirmour (H.P) (SH:-Supply and errection of pumping machinery, D/system, soft starter, RCC OHSR, R/main and Pump house for drinking water supply scheme). | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Trilokpur | |||
2 | 1.01 | Supply, erection, testing & commissioning of submersible pumping set of reputed make such as KSB/BS/Johnston/Worthington/Sabar/Oswal conforming to latest relevent BIS code. The pump should be fitted with free flow impellers of bronze /suitable alloy as per BIS 5659 or latest with up to date ammendments suitable for raw/clear water having characterstics as mentioned in items (A) greased packed bearings & shell with wound stator on motor side & with shaft protection sleeve on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to a submersible squirrel cage electric induction motor of Kirloskar/NGEF/Jyoti / Crompton make conforming to relevent BIS code with up to date ammendments totally dust & water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber chamber & grease packed lubricated bearings & provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor. The pump set should include water level guard, errection clamps, cable clips & depth gauge etc. & suitable for operation on data given below:- | 2 | Per Set | |
3 | 1.02 | Total Head in mtrs 293.21 mtrs | |||
4 | 1.03 | Capacity (in LPS) each pump set 15.1272 lps | |||
5 | 1.04 | Dia of R/Main (in mm) 150 mm | |||
6 | 1.05 | Dia of Column pipe (in mm) | |||
7 | 1.06 | HP:- 2x120HP= 240 HP | |||
8 | 2 | Providing and fixing of Auto control panel with push button star delta starter for submersible pumps of L&T and reputed make fabricated with M.S sheet and Angle stand duly painted and complete with internal wiring ,comprising of main switch of suitable Amp. T.P. Volt meter, ammeter,hour run meter, phase indicating lamps with GSM based , Remote start/stop operation call/SMS for feedback regarding running of pumps & breakdown message, timer scheduling for fixed hours in a day,Inbuilt protection against overload/undervoltage,Dry run,single phase preventor,Inbuilt GPS tracker,phase reversal configurable volt/current limits with a facility to access the system through minimum 10 Nos. authenticated mobile Nos. complete in all respect, including entire carriage of materials upto all leads and lifts,installation and testing at site with entire satisfaction of Engineer-in-charge. | 1 | Each | |
9 | 3 | Supply &fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Bir/ Karter make of Cast iron / Cast steel double flanged sluice valve having size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a) & conforming to API-standards with up to date ammendments for delivery line of pump class PN 1.6 , 50mm dia. | 1 | Each | |
10 | 3.01 | Supply &fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader / Karter/Pelicon make of suitable size cast iron double flanged swing check type reflux valve for delivery line of pump having bye pass arrangement & size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a) & conforming to API-standards with up to date ammendments for delivery line of pump . | 1 | Each | |
11 | 3.02 | Supply & fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Pelicon make of suitable size Cast Steel double flanged swing check type reflux valve conirming to API/ standard with up to date ammendments for R/main as mentioned in item No.12(c) for withstanding nominal seat pressure as per item No.1(a) .The size of reflux valve shall be equal to size of Rising main of the same shall be provided with suitable bye pass arrangements class 80mm dia | 1 | Each | |
12 | 3.03 | Supply & fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader make cast iron flanged screwed foot valve for suction pipe having size one or two size larger than suction size of pump such that valocity of flow in suction pipe is not more than 3.00 mtr/sec aconforming to BIS 4038-1986 or latest with stainer of dia equal three to four tomes of dia of suction pipe with up to date ammendments class PN 1.6 , 80mm dia. | 1 | Each | |
13 | 4 | P/L suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC make from meter of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost of 15 Rmt. | 1 | Per Job | |
14 | 4.01 | P/L PVC jointless flat water proof cable as per BIS 694-1990 (latest with up to date ammendments) suitable for the pump sets offered from circuite breaker to motor & motor to starter including all other electrical equipments such as thimbles, flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost. | 1 | Per Job | |
15 | 4.02 | P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments. | 1 | Per Job | |
16 | 4.03 | Supply & errection of floor/wall mounted power factor shunt capacitor of suitable KVAR conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer). | 1 | Each | |
17 | 5 | Supply and fixing st site of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 or latest with up to date ammendments. | 1 | Each | |
18 | 6 | P/F double flanged suction, delivery pipe & common header considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 1e(ii). The size of suction pipe shall be one or two size larger than nominal suction size of pump such that valocity of flow in suction pipe is not more than 3.00 mtr/sec.& size of delivery pipe shall be one size larger than nominal delivery size of pump. | 1 | Per Job | |
19 | 6.01 | Note :- Actual laying to be done as per final drawing to be approved by the Engineer Incharge. | |||
20 | 7 | Supply of antivibration pads conforming to BIS 6337-1971 or latest with upto date ammendments of suitable size for above machinery. | 1 | Per set | |
21 | 8 | Errection of all equipments from S.No. 1 to 4, 6 & 8 including cost of tees bends tapers and any other fittings required as per site conditions and as per direction of the Engineer Incharge. | 1 | Per Job | |
22 | 9 | Kheri | |||
23 | 9.01 | Supply, erection, testing & commissioning of submersible pumping set of reputed make such as KSB/BS/Johnston/Worthington/Sabar/Oswal conforming to latest relevent BIS code. The pump should be fitted with free flow impellers of bronze /suitable alloy as per BIS 5659 or latest with up to date ammendments suitable for raw/clear water having characterstics as mentioned in items (A) greased packed bearings & shell with wound stator on motor side & with shaft protection sleeve on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to a submersible squirrel cage electric induction motor of Kirloskar/NGEF/Jyoti / Crompton make conforming to relevent BIS code with up to date ammendments totally dust & water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber chamber & grease packed lubricated bearings & provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor. The pump set should include water level guard, errection clamps, cable clips & depth gauge etc. & suitable for operation on data given below:- | 2 | Per Set | |
24 | 9.02 | Total Head in mtrs 158.54 mtrs | |||
25 | 9.03 | Capacity (in LPS) each pump set 9.394 lps | |||
26 | 9.04 | Dia of R/Main (in mm) 125 mm | |||
27 | 9.05 | Dia of Column pipe (in mm) | |||
28 | 9.06 | HP:- 2x40= 80 HP | |||
29 | 10 | Providing and fixing of Auto control panel with push button star delta starter for submersible pumps of L&T and reputed make fabricated with M.S sheet and Angle stand duly painted and complete with internal wiring ,comprising of main switch of suitable Amp. T.P. Volt meter, ammeter,hour run meter, phase indicating lamps with GSM based , Remote start/stop operation call/SMS for feedback regarding running of pumps & breakdown message, timer scheduling for fixed hours in a day,Inbuilt protection against overload/undervoltage,Dry run,single phase preventor,Inbuilt GPS tracker,phase reversal configurable volt/current limits with a facility to access the system through minimum 10 Nos. authenticated mobile Nos. complete in all respect, including entire carriage of materials upto all leads and lifts,installation and testing at site with entire satisfaction of Engineer-in-charge. | 1 | Each | |
30 | 11 | Supply &fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Bir/ Karter make of Cast iron / Cast steel double flanged sluice valve having size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a) & conforming to API-standards with up to date ammendments for delivery line of pump class PN 1.6 , 50mm dia. | 1 | Each | |
31 | 11.01 | Supply &fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader / Karter/Pelicon make of suitable size cast iron double flanged swing check type reflux valve for delivery line of pump having bye pass arrangement & size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a) & conforming to API-standards with up to date ammendments for delivery line of pump . | 1 | Each | |
32 | 11.02 | Supply & fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Pelicon make of suitable size Cast Steel double flanged swing check type reflux valve conirming to API/ standard with up to date ammendments for R/main as mentioned in item No.12(c) for withstanding nominal seat pressure as per item No.1(a) .The size of reflux valve shall be equal to size of Rising main of the same shall be provided with suitable bye pass arrangements class 80mm dia | 1 | Each | |
33 | 11.03 | Supply & fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader make cast iron flanged screwed foot valve for suction pipe having size one or two size larger than suction size of pump such that valocity of flow in suction pipe is not more than 3.00 mtr/sec aconforming to BIS 4038-1986 or latest with stainer of dia equal three to four tomes of dia of suction pipe with up to date ammendments class PN 1.6 , 80mm dia. | 1 | Each | |
34 | 12 | P/L suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC make from meter of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost of 15 Rmt. | 1 | Per Job | |
35 | 12.01 | P/L PVC jointless flat water proof cable as per BIS 694-1990 (latest with up to date ammendments) suitable for the pump sets offered from circuite breaker to motor & motor to starter including all other electrical equipments such as thimbles, flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost. | 1 | Per JOb | |
36 | 12.02 | P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments. | 1 | Per Job | |
37 | 12.03 | Supply & errection of floor/wall mounted power factor shunt capacitor of suitable KVAR conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer). | 1 | Each | |
38 | 13 | Supply and fixing st site of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 or latest with up to date ammendments. | 1 | Each | |
39 | 14 | P/F double flanged suction, delivery pipe & common header considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 1e(ii). The size of suction pipe shall be one or two size larger than nominal suction size of pump such that valocity of flow in suction pipe is not more than 3.00 mtr/sec.& size of delivery pipe shall be one size larger than nominal delivery size of pump. | 1 | Per Job | |
40 | 14.01 | Note :- Actual laying to be done as per final drawing to be approved by the Engineer Incharge. | |||
41 | 15 | Supply of antivibration pads conforming to BIS 6337-1971 or latest with upto date ammendments of suitable size for above machinery. | 1 | Per set | |
42 | 16 | Errection of all equipments from S.No. 1 to 4, 6 & 8 including cost of tees bends tapers and any other fittings required as per site conditions and as per direction of the Engineer Incharge. | 1 | Per Job | |
43 | 17 | Johron | |||
44 | 17.01 | Supply, erection, testing & commissioning of submersible pumping set of reputed make such as KSB/BS/Johnston/Worthington/Sabar/Oswal conforming to latest relevent BIS code. The pump should be fitted with free flow impellers of bronze /suitable alloy as per BIS 5659 or latest with up to date ammendments suitable for raw/clear water having characterstics as mentioned in items (A) greased packed bearings & shell with wound stator on motor side & with shaft protection sleeve on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to a submersible squirrel cage electric induction motor of Kirloskar/NGEF/Jyoti / Crompton make conforming to relevent BIS code with up to date ammendments totally dust & water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber chamber & grease packed lubricated bearings & provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor. The pump set should include water level guard, errection clamps, cable clips & depth gauge etc. & suitable for operation on data given below:- | 2 | Per set | |
45 | 17.02 | Total Head in mtrs 296.010 mtrs | |||
46 | 17.03 | Capacity (in LPS) each pump set 4.58 lps | |||
47 | 17.04 | Dia of R/Main (in mm) 80 mm | |||
48 | 17.05 | Dia of Column pipe (in mm) | |||
49 | 17.06 | HP:- 2x40= 80 HP | |||
50 | 18 | Providing and fixing of Auto control panel with push button star delta starter for submersible pumps of L&T and reputed make fabricated with M.S sheet and Angle stand duly painted and complete with internal wiring ,comprising of main switch of suitable Amp. T.P. Volt meter, ammeter,hour run meter, phase indicating lamps with GSM based , Remote start/stop operation call/SMS for feedback regarding running of pumps & breakdown message, timer scheduling for fixed hours in a day,Inbuilt protection against overload/undervoltage,Dry run,single phase preventor,Inbuilt GPS tracker,phase reversal configurable volt/current limits with a facility to access the system through minimum 10 Nos. authenticated mobile Nos. complete in all respect, including entire carriage of materials upto all leads and lifts,installation and testing at site with entire satisfaction of Engineer-in-charge. | 1 | Each | |
51 | 19 | Supply &fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Bir/ Karter make of Cast iron / Cast steel double flanged sluice valve having size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a) & conforming to API-standards with up to date ammendments for delivery line of pump class PN 1.6 , 50mm dia. | 1 | Each | |
52 | 19.01 | Supply &fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader / Karter/Pelicon make of suitable size cast iron double flanged swing check type reflux valve for delivery line of pump having bye pass arrangement & size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a) & conforming to API-standards with up to date ammendments for delivery line of pump . | 1 | Each | |
53 | 19.02 | Supply & fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Pelicon make of suitable size Cast Steel double flanged swing check type reflux valve conirming to API/ standard with up to date ammendments for R/main as mentioned in item No.12(c) for withstanding nominal seat pressure as per item No.1(a) .The size of reflux valve shall be equal to size of Rising main of the same shall be provided with suitable bye pass arrangements class 80mm dia | 1 | Each | |
54 | 19.03 | Supply & fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader make cast iron flanged screwed foot valve for suction pipe having size one or two size larger than suction size of pump such that valocity of flow in suction pipe is not more than 3.00 mtr/sec aconforming to BIS 4038-1986 or latest with stainer of dia equal three to four tomes of dia of suction pipe with up to date ammendments class PN 1.6 , 80mm dia. | 1 | Each | |
55 | 20 | P/L suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC make from meter of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost of 15 Rmt. | 1 | Per Job | |
56 | 20.01 | P/L PVC jointless flat water proof cable as per BIS 694-1990 (latest with up to date ammendments) suitable for the pump sets offered from circuite breaker to motor & motor to starter including all other electrical equipments such as thimbles, flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost. | 1 | Per JOb | |
57 | 20.02 | P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments. | 1 | Per Job | |
58 | 20.03 | Supply & errection of floor/wall mounted power factor shunt capacitor of suitable KVAR conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer). | 1 | Each | |
59 | 21 | Supply and fixing st site of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 or latest with up to date ammendments. | 1 | Each | |
60 | 22 | P/F double flanged suction, delivery pipe & common header considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 1e(ii). The size of suction pipe shall be one or two size larger than nominal suction size of pump such that valocity of flow in suction pipe is not more than 3.00 mtr/sec.& size of delivery pipe shall be one size larger than nominal delivery size of pump. | 1 | Per JOb | |
61 | 22.01 | Note :- Actual laying to be done as per final drawing to be approved by the Engineer Incharge. | |||
62 | 23 | Supply of antivibration pads conforming to BIS 6337-1971 or latest with upto date ammendments of suitable size for above machinery. | 1 | Per Set | |
63 | 24 | Errection of all equipments from S.No. 1 to 4, 6 & 8 including cost of tees bends tapers and any other fittings required as per site conditions and as per direction of the Engineer Incharge. | 1 | Per Job | |
64 | 25 | Soft Starter | |||
65 | 25.01 | Trilokpur | |||
66 | 25.02 | Providing , fixing and successfully testing of Microprocessor based Fully Programmable Soft Starter of 50HP Crompton Greaves / SIEMENS/ ALLEN- BRADLEY or Equivalent make certified by CE/UL/CSA suitable for motor operating in 200-480 VAC , 3 phase ambient temperature of 25 Dig Cen to 60 Dig Cen . Ramp Up time 0-20 secs, with in-built Bye-Pass System, fully programmable .All digital display connecting with motor etc. and all connections needed to make the Motor Pump run successfully. The equipment should be compatible/upgradable for use with Future Automation of the Scheme | 1 | Each | |
67 | 26 | Providing , fixing and successfully testing of Floor Mounted Soft Starter Cabinet fabricated (PANEL W = 750 mm X H= 750 mm X D = 450 mm Approx ) of Advance Engineer or Equivalent make including Panel Board with accessories of reputed make Main Incoming MCCB, power supply, MCB,relays, with Ammeter , Volt meter , Push Button and Single Phase Preventer complete wiring thimbles etc . All digital display connecting with motor etc. and all connections needed to make the Motor Pump run successfully. The equipment should be compatible/upgradable for use with Future Automation of the Scheme | 1 | Each | |
68 | 27 | Providing , Fixing and successfully testing of Microprocessor based submersible dedicated Controller of GE/Siemens or Equivalent make certified by CE/UL/CSA suitable for 200-240 VAC , Single Phase ambient temperature of 50 Dig . The controller should be of expandable type and should have 1 serial port, Option of adding Ethernet/Modbus Ports in future, Local IO Indication LED’s. Inbuilt IO isolation , Real Time Clock , Floating Math & Motion Support | 1 | Each | |
69 | 28 | Providing, fixing and successfully testing of Microprocessor Based, \nFully programmable Touch Screen of 4.5 ‘’ Proface/Fuji/Equivalent make. Power Supply 230VAC/24VDC, \nOnboard Serial / Ethernet Interface, Communication cable between controller & HMI . \nThe HMI should have inbuilt Mimic , Libraries for Water Supply Dept. , \nMulti time setting Driver Support to telemetry Scada | 1 | Each | |
70 | 29 | Kheri | |||
71 | 29.01 | Providing , fixing and successfully testing of Microprocessor based Fully Programmable Soft Starter of 50HP Crompton Greaves / SIEMENS/ ALLEN- BRADLEY or Equivalent make certified by CE/UL/CSA suitable for motor operating in 200-480 VAC , 3 phase ambient temperature of 25 Dig Cen to 60 Dig Cen . Ramp Up time 0-20 secs, with in-built Bye-Pass System, fully programmable .All digital display connecting with motor etc. and all connections needed to make the Motor Pump run successfully. The equipment should be compatible/upgradable for use with Future Automation of the Scheme | 1 | Each | |
72 | 30 | Providing , fixing and successfully testing of Floor Mounted Soft Starter Cabinet fabricated (PANEL W = 750 mm X H= 750 mm X D = 450 mm Approx ) of Advance Engineer or Equivalent make including Panel Board with accessories of reputed make Main Incoming MCCB, power supply, MCB,relays, with Ammeter , Volt meter , Push Button and Single Phase Preventer complete wiring thimbles etc . All digital display connecting with motor etc. and all connections needed to make the Motor Pump run successfully. The equipment should be compatible/upgradable for use with Future Automation of the Scheme | 1 | Each | |
73 | 31 | Providing , Fixing and successfully testing of Microprocessor based submersible dedicated Controller of GE/Siemens or Equivalent make certified by CE/UL/CSA suitable for 200-240 VAC , Single Phase ambient temperature of 50 Dig . The controller should be of expandable type and should have 1 serial port, Option of adding Ethernet/Modbus Ports in future, Local IO Indication LED’s. Inbuilt IO isolation , Real Time Clock , Floating Math & Motion Support | 1 | Each | |
74 | 32 | Providing, fixing and successfully testing of Microprocessor Based, \nFully programmable Touch Screen of 4.5 ‘’ Proface/Fuji/Equivalent make. Power Supply 230VAC/24VDC, \nOnboard Serial / Ethernet Interface, Communication cable between controller & HMI . \nThe HMI should have inbuilt Mimic , Libraries for Water Supply Dept. , \nMulti time setting Driver Support to telemetry Scada | 1 | Each | |
75 | 33 | Johron | |||
76 | 33.01 | Providing , fixing and successfully testing of Microprocessor based Fully Programmable Soft Starter of 50HP Crompton Greaves / SIEMENS/ ALLEN- BRADLEY or Equivalent make certified by CE/UL/CSA suitable for motor operating in 200-480 VAC , 3 phase ambient temperature of 25 Dig Cen to 60 Dig Cen . Ramp Up time 0-20 secs, with in-built Bye-Pass System, fully programmable .All digital display connecting with motor etc. and all connections needed to make the Motor Pump run successfully. The equipment should be compatible/upgradable for use with Future Automation of the Scheme | 1 | Each | |
77 | 34 | Providing , fixing and successfully testing of Floor Mounted Soft Starter Cabinet fabricated (PANEL W = 750 mm X H= 750 mm X D = 450 mm Approx ) of Advance Engineer or Equivalent make including Panel Board with accessories of reputed make Main Incoming MCCB, power supply, MCB,relays, with Ammeter , Volt meter , Push Button and Single Phase Preventer complete wiring thimbles etc . All digital display connecting with motor etc. and all connections needed to make the Motor Pump run successfully. The equipment should be compatible/upgradable for use with Future Automation of the Scheme | 1 | Each | |
78 | 35 | Providing , Fixing and successfully testing of Microprocessor based submersible dedicated Controller of GE/Siemens or Equivalent make certified by CE/UL/CSA suitable for 200-240 VAC , Single Phase ambient temperature of 50 Dig . The controller should be of expandable type and should have 1 serial port, Option of adding Ethernet/Modbus Ports in future, Local IO Indication LED’s. Inbuilt IO isolation , Real Time Clock , Floating Math & Motion Support | 1 | Each | |
79 | 36 | Providing, fixing and successfully testing of Microprocessor Based, \nFully programmable Touch Screen of 4.5 ‘’ Proface/Fuji/Equivalent make. Power Supply 230VAC/24VDC, \nOnboard Serial / Ethernet Interface, Communication cable between controller & HMI . \nThe HMI should have inbuilt Mimic , Libraries for Water Supply Dept. , \nMulti time setting Driver Support to telemetry Scada | 1 | Each | |
80 | 37 | Rising Main | |||
81 | 37.01 | Excavation in Drain and Channel in earth work in all kinds of soil Kankar, Moorum, Shingles conglomerate saturated soil decomposed such as containing spade work, , jumper work including decomposed soft and hard rock ,Pucca /metelled /Katcha /concrete/pavers road and paths etc including any hindrences, restoration of cables ,pipe network ,consumer connection /pavers /tiles during day or night with all material all kinds dressing of sides and beds, disposing of excavated earth with all leads,lifts disposal earth to be levelled and neatly dressed and returning the stacked soil into foundation and trenches etc. including ramming and consolidating the same whereever required with all leads ,lifts in cluding jungle clearance , making level with road surface with in all leads, lifts foundation etc.& complete in all respects and as directed by the Engineer Incharge as per CPHEEO mannual. | 7657.17 | Per Cum | |
82 | 38 | Providing and laying testing & commissioning at site in trenches following plain ended GMS pipes of heavy/ medium gread as under confiriming to BIS 1229 (part-1) 1990 or latest with upto date ammendments capable of with stading requierd test pressure as prescribed in BIS code in randum lenghts of 5.5 to 6.50 mtr the pipes ends shall be bevelled sutaible for butt weld including the cosdt of jointing with butt welding conforming to IS 816-1969 or latest as aplicable (leak proof) in three layers at site of work with welding rods of standard make and all allied accessories whatever requried for welding at site tail pieces tees bends manufatured from parent pipes etc, and cutting of pipes whatevev required as pr site requirment including carriage all leads and lifts as directed by the Engineer Incharge (Earth wook shall be measured & paid for seprately ) | |||
83 | 38.01 | S.No R.Ds Nominal Dia Length (in Mtrs) | |||
84 | 38.02 | Trilokpur | |||
85 | 38.03 | 1 0 1920 150mm ( H) 1920 | 1920 | Per Rmt | |
86 | 38.04 | 2 1920 3840 150mm ( M) 1920 | 1920 | Per Rmt | |
87 | 38.05 | Kheri | |||
88 | 38.06 | 1 0 450 125mm ( H) 450 | 450 | Per Rmt | |
89 | 38.07 | Johron | |||
90 | 38.08 | 1 0 900 80mm ( H) 900 | 900 | Per Rmt | |
91 | 39 | Providing, welding and fixing M.S. plate flanges of various dia (nominal bore) of following Flange Tables confirming to IS 6392-1971 or latest with up to date ammendments to API/ MSERW/G.I Pipe as per site requirement including cutting of of pipes wherever required, welding in three layers (leak proof) confirming to specifications as prescribed in relvent I.S. Code i.e. IS 816-1969 or latest as applicable with up to date ammendments with nuts, bolts & washers & specials etc. confirming to IS-1963 or latest with up to date ammendments including packing sheet i.e. asbestos fibre sheet minimum 3mm thick and painting with anticorosive paints complete in all respect including all leads and lifts and as per entire satisfaction of Engineer - in - charge | |||
92 | 39.01 | S.No R.Ds Nominal Dia Length (in Mtrs) FT | |||
93 | 39.02 | Trilokpur | |||
94 | 39.03 | 1 0 480 150mm 480 FT - 28 | 6 | Per Pair | |
95 | 39.04 | 2 480 3360 150mm 2880 FT - 17 | 32 | Per Pair | |
96 | 39.05 | 3 3360 3840 150mm 480 FT - 5 | 6 | Per Pair | |
97 | 39.06 | Kheri | |||
98 | 39.07 | 1 0 450 125mm 450 FT-5 | 5 | Per Pair | |
99 | 39.08 | Johron | |||
100 | 39.09 | 1 0 360 80mm 360 FT - 28 | 6 | Per Pair | |
101 | 39.1 | 2 360 720 80mm 360 FT - 17 | 32 | Per Pair | |
102 | 39.2 | 3 720 900 80mm 180 FT - 5 | 6 | Per Pair | |
103 | 40 | Distribution System | |||
104 | 40.01 | Laying , jointing, testing & commissioning in trenches following dia socketted galvanised mild steel tube of various dia of grade as under confirming to BIS 1239-(Part-1)-1990 or latest with up to date ammendments, capable of with standing required test pressure as BIS code, in randum lengths of 5.5 to 6.5 mtr. The pipe ends shall be socketted , tees, bends manufactured from parent pipe etc and cutting of pipes whereever required as per stie requirement as per site conditions i/c carriage in all leads & lifts and as directed by Engineer-Incharge. (Earth work shall be measured paid for seperately). | |||
105 | 40.02 | 65 mm. Dia | 1980 | Per Rmt | |
106 | 40.03 | 50 mm. Dia | 2960 | Per Rmt | |
107 | 40.04 | 40 mm. Dia | 2050 | Per Rmt | |
108 | 40.05 | 32 mm. Dia | 2150 | Per Rmt | |
109 | 41 | Providing and fixing brass full way valves with wheel of approved make and relevent ISS complete in all respects including of all leads, lifts and carriage of material at site and as directed by the Engineer Incharge. | |||
110 | 41.01 | 65 mm. Dia | 2 | Each | |
111 | 41.02 | 50 mm. Dia | 2 | Each | |
112 | 41.03 | 40 mm. Dia | 10 | Each | |
113 | 41.04 | 32 mm. Dia | 5 | Each | |
114 | 42 | Construction of chamber1.00x1.00x.9 for the fixing of common head for the operation of Gate Valves compleat with all including ramming and consolidating the same whereever required with all leads, lifts and including jungle clearance and as per the direction of the Engineer Incharge. | 4 | Each | |
115 | 43 | OHSR | |||
116 | 43.01 | Construction of OHSR with 14 mtrs staging for Trilokpur complete in all respect as per site requirement including carriage all leads and lifts as directed by Engineer in charge, with all respect | 250000 | Per Ltrs | |
117 | 44 | Construction of OHSR with 12 mtrs staging for Kheri complete in all respect as per site requirement including carriage all leads and lifts as directed by Engineer in charge, with all respect | 135000 | Per Ltrs | |
118 | 45 | Construction of OHSR with 14 mtrs staging for Johron complete in all respect as per site requirement including carriage all leads and lifts as directed by Engineer in charge, with all respect | 335000 | Per Ltrs | |
119 | 46 | Pump House 3 Nos ( Trilokpur, Kheri, Johron.) | |||
120 | 46.01 | Excavation in foundation and trenches etc. in earth work including all kinds of soil such as pick work jumper work,blasting soft and hard rock, conglomirate,upto all leads and lift stacked the excavated soil not more then 3 mtr. Clear from the edge of excavation and then returning the stacked soil in trenches consolidating each deposited layer by ramming and watering and then disposing of all surplus surplus excavted earth as directed by the Engineer-in-Charge | 58.83 | Per cum | |
121 | 47 | Providing and laying cement concrete 1:6:12 (1cement:6sand:12graded stone aggregate 40 mm nominal size) and curing complete excluding cost of form work in foundation and plinth.Including entire carriage of material upto all leads and lifts. | 25.68 | Per cum | |
122 | 48 | 2ndclass brick work using common burnt clay building bricks in fioundation and plinth in cement mortor 1:6(1cement:6sand)including entire carriage of material upto all leads and lifts. | 32.97 | Per cum | |
123 | 49 | Providing and laying damp proof course 38 mm thick with cement concrete 1:2:4(1cement:2sand :4graded stone aggregate 12.5mm nominal size_) & curing complete.including entire carriage of material upto all leads and lifts | 17.16 | Per Sqmtr | |
124 | 50 | Applying a coat of hot bitumen (Maxphalt 80/100 or equivalent)using 1.70m kg/sq. mtr. On damp proof course after cleaning the surface with a piece of cloth lightly soaked with kerosene oil.including entire carriage of materil uopto all leads and lifts. | 17.16 | Per Sqmtr | |
125 | 51 | 2nd class brick work using common burnt clay building bricks in superstructure in cement mortar 1:6(1cement:6sand)including entire carriage of material upto all leads and lifts. | 41.85 | Per cum | |
126 | 52 | Providing form work with steel plates 3.15 mm thick welded with angle iron in frame 30x30x5 mm so as to give a fair finish including centring & shuttering and propping etc. with wooden batten and ballies,heightof propping and centring below supporting floor to ceiling not exceeding 4mtrs removal of the same for insitu RCC and PCC work in flat surfaces such as sofits,suspended floors.roofs,landing and the like floors etc. 200mm thickness .including entire carriage of material upto all leads and lifts. | 81.93 | Per Sqmtr | |
127 | 53 | Providing and laying RCC work 1:2:4(1cement:2 sand:4graded stone aggregate 20mm nominal size)and curing complete excluding cost of form work and reinforcement for RCC work in suspended floors,roofs etc. including entire carriage of material upto all leads and lifts. | 12.75 | Per cum | |
128 | 54 | Providing tor steel reinforcement for RCC work including bending,winding and placing in position complete upto floor two level.including entire carriage of material upto all leads and lifts. | 1147.5 | Per Kg | |
129 | 55 | 20 mm cement plaster in single coat on rough side of brick masonary for interior plaster upto floor two level including arrises,internal rounded angles,chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth with cement mortar 1:3(1cement:3 sand) including entire carriage of material upto all leads and lifts. | 21.69 | Per Sqmtr | |
130 | 56 | 15 mm cement plaster in single coat on rough side of brick masonary for interior plaster upto floor two level including arrises,internal rounded angles,chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth with cement mortar 1:3(1cement:3 sand) including entire carriage of material upto all leads and lifts. | 201.78 | Per Sqmtr | |
131 | 57 | Pointing on brick work with cement mortar 1:3 (1cement:3sand) Ruled pointing including entire carriage of material upto all leads and lifts. | 162.9 | Per Sqmtr | |
132 | 58 | Providing wood work in frame of doors windows and clerestory windows and other frame work wrough framed and fixed in position(2 nd class deodar. Wood). | 0.96 | Per cum | |
133 | 59 | Providing fixing panelled glazed or panelled and glazedshutters for doors windows and clerestory window including black enamelled iron butt hinges with necessary screws 40mm thick 2nd class deodar wood.including entire carriage of material upto all leads and lifts. | 36.72 | Per Sqmtr | |
134 | 60 | Cement concrete flooring 1:2:4 (1cement:2sand :4graded stone aggregate 20 mm nominal size) laid in one layer finished with floating coat of neat cement 40 mm thick.including entire carriage of material upto all leads and lifts. | 65.25 | Per cum | |
135 | 61 | Applying priming coat over new wood and wood based surfaces after and including preparing the surface by throughly cleaning oil,grease,dirt and other foreign matter .with ready mixed paint brushing wood primer pink.including entire carriage of material upto all leads and lifts. | 77.76 | Per Sqmtr | |
136 | 62 | Painting two coat excluding priming coat on new wood and wood surfaces with enamel paint to give an even shade including cleaning the surface of dirt,dust and other foreign matter sand papering & stoping.including entire carriage of material upto all leads & lifts | 77.76 | Per Sqmtr | |
137 | 63 | White washing with lime on decorated wall surfaces(three coats) to give an even shade including throughly brooming the surface to remove all dirt dust mortar drops and loose scale of lime wash and other foreign matter.including entire carriage ofmaterial upto all leads and lifts. | 201.78 | Per Sqmtr | |
138 | 64 | Construction of stone kharanja drain 45 cm wide in C.M. 1:6(1cement:6sand) including entire carriage of material upto all leads and lifts. | 76.5 | Per Rmt | |
139 | 65 | Providing plinth protection 50 mm thick in cement concrete 1:3:6 (1cement:3sand:6 graded stone aggregate 20 mm nominal size)including entire carriage of material upto all leads and lifts. | 33.18 | Per Sqmtr | |
140 | 66 | Providing 40x3 mm flat iron hold fast 40cms long including fixing to frame with 10mm diameter bolts nuts and wooden plugs and embedding in cement concrete block 30x10x15cms 1:3:6 (1cement:3sandf:6graded stone aggregate 20mm nominal size) including entire carriage of material upto all leads and lifts. | 72 | Each | |
141 | 67 | Providing fixing Aluminium tower bolts barrel type anodized transparent or dyed to required shade and colour with screws etc. complete 250x10 mm | 60 | Each | |
142 | 68 | Providing fixing aluminium handle anodized transparent or dyed to req. shade and colour with screws etc. complete. 125 mm | 66 | Each | |
143 | 69 | Providing fixing sliding door bolts anodized transparent or dyed to required shade and colour with screws etc. complete. 250x16 mm.based surfaces after and including preparing thethe surface by throughly cleaning oil,grease,dirt and other foreign matter .with ready mixed paint brushing wood primer pink.including entire carriage of material upto all leads and lifts. | 6 | Each | |
144 | 70 | Providing fixing electric fitting in pump house including entire carriage of material upto all leads and lifts.with screws etc. complete. | 3 | Per Job |