Special Repair To Primary Health Center At Village Achina/ Ranila/ Chhapar/ Mankwas In Distt . Ch . Dadri ( Pdg . E . I Internal Only ) Recall
BOQ
| Name of Work: Special Repair to Primary Health Center at Village Achina/ Ranila/ Chhapar/ Mankwas in Distt. Ch. Dadri (Pdg. E.I Internal only) | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Main Switches Supply and erection of metal clad switches / B.D.Bs with rag bolts on wall or on existing angle iron board / pedestal including bonding to earth and necessary connections. (HSR 31.12 (a). vi) Double pole switch 63 amp. 415 Volts Cat-B. | BI01010001010000000000000515BI0100001113 | 4 | Each |
| 2 | 2 | Miniature Circuit Breaker and Isolator. Supply and erection of miniature circuit breaker / isolator 240 /415 V in the existing distribution board including making necessary connections. (HSR 31.17). Miniature circuit breakers of 9 KA breaking capacity. ii) SP MCB 6 amp. to 32 amp. | BI01010001010000000000000515BI0100001114 | 100 | Each |
| 3 | 2.1 | iii) SPN MCB 6 amp. To 32 amp. | BI01010001010000000000000515BI0100001115 | 4 | Each |
| 4 | 3 | Supply and erection of Fittings and Accessories (HSR 31.18) xi) Bakelite angle / straight button holder large size. | BI01010001010000000000000515BI0100001116 | 32 | Each |
| 5 | 3.1 | vii) Call bell 220 / 230 volts A.C. bakelite with double coil. | BI01010001010000000000000515BI0100001117 | 4 | Each |
| 6 | 3.2 | ix) Bell push flush type ( without flexible wire ) in existing sheet. | BI01010001010000000000000515BI0100001118 | 4 | Each |
| 7 | 3.3 | xii) Switch 5 amp. On existing sheet. | BI01010001010000000000000515BI0100001119 | 40 | Each |
| 8 | 3.4 | xiii) Wall socket 5 amp. On existing sheet. | BI01010001010000000000000515BI0100001120 | 40 | Each |
| 9 | 3.5 | xxiv) Erection only of 1x40 watts or 2x40 watts 1220 mm long / 1x20 watts or 2x20 watts ,610 mm long fluorescent tube fitting directly on wall including necessary connections with 0.75 sqmm ( 24 / 0.20 mm ) PVC copper flexible cable for connecting the tube with the adjecent point. | BI01010001010000000000000515BI0100001121 | 120 | Each |
| 10 | 4 | Under Ground Cables. Supply and erection of under ground cable ,loose in existing pipe or trenches complete with necessary connections. (HSR 31.26) iv) 10 Sq. mm 2 Core Ard.Cable. | BI01010001010000000000000515BI0100001122 | 240 | P/M |
| 11 | 5 | Supply and erection of suitable compression type brass cable glands for underground Cable. (HSR 31.28). ii) 10 Sqmm to 16 Sqmm Cable 2 to 4 Core . | BI01010001010000000000000515BI0100001123 | 32 | Each |
| 12 | 6 | Street Light. (HSR 31.30) IV) Supply and erection of weather proof M.S.Box of size 20 cm x 15 cm x 10 cm. covered with 3.00 mm thick M.S.sheet hinged cover, locking arrangements , housed in wall , including the cost of 1 no. 16 amp. 415 volts kit-kat and 2 nos. 63 amp. 415 volts neutral links fixed on hard wood board in the M.S.Box including painting and necessary connections . | BI01010001010000000000000515BI0100001124 | 16 | Each |
| 13 | 7 | Miscellaneous (HSR 31.35) i) Supply of M.S.pipe (B-Class) for suspension rod of ceiling fan including threading if required. 15 mm dia. | BI01010001010000000000000515BI0100001125 | 20 | P/M |
| 14 | 8 | Wiring only in 1.5sqmm PVC insulated copper conductor cable in existing conduit pipe and MS box covered with 5 mm thick Bakelite sheet including cost of switch, wall socket, ceiling rose etc. (HSR 31.38). I) Fan Point b) Medium Point | BI01010001010000000000000515BI0100001126 | 8 | Each |
| 15 | 8.1 | c) Long point | BI01010001010000000000000515BI0100001127 | 20 | Each |
| 16 | 8.2 | II) Light Point a) Short Point | BI01010001010000000000000515BI0100001128 | 20 | Each |
| 17 | 8.3 | b) Medium Point | BI01010001010000000000000515BI0100001129 | 40 | Each |
| 18 | 8.4 | c) Long point | BI01010001010000000000000515BI0100001130 | 32 | Each |
| 19 | 8.5 | VI) Call bell point c) Long point | BI01010001010000000000000515BI0100001131 | 4 | Each |
| 20 | 8.6 | VII) 3-pin 5 amp. Plug point including earthing the 3rd pin etc. c) Long point | BI01010001010000000000000515BI0100001132 | 8 | Each |
| 21 | 8.7 | VIII) 3-pin15 amp. Plug point with 4 sqmm PVC insulated copper conductor cable including earthing the 3rd pin etc. c) Long point | BI01010001010000000000000515BI0100001133 | 8 | Each |
| 22 | 9 | S/E of of PVC unsheathed copper conductor cable single core 1100 volts grad in pipe of suitable size excluding cost and erection of pipe. (HSR 31.40) i) Cable size 1.5 sqm(3/0.81 mm) | BI01010001010000000000000515BI0100001134 | 1000 | P/M |
| 23 | 9.1 | iii) Cable size 4 sqm(7/0.85 mm) | BI01010001010000000000000515BI0100001135 | 480 | P/M |
| 24 | 9.2 | v) Cable size 10 sqm(7/1.35 mm) | BI01010001010000000000000515BI0100001136 | 40 | P/M |
| 25 | 10 | S/E of MS saddles and clamps on wall/ RCC parapet for fixing underground cable at a distance of 0.60 meter centre to centre fixed by means of rawl plug including the cost of all labour and material required to complete the job in all respect upto the Engineer-in-Charge of the work. (HSR 31.48). | BI01010001010000000000000515BI0100001137 | 192 | Each |
| 26 | 11 | Supply & erection of Socket size rotary step type Electronic regulator for A.C. ceiling fan Anchor make Delux model No. 50440 ISI / SSK make PC 561 operated on 120/280 V A.C. Supply complete including cutting of existing Bakelite sheet and making necessary connection ect upto the entire satisfaction of the Engineer-in-Charge of the work. (HSR 31.55). | BI01010001010000000000000515BI0100001138 | 60 | Each |
| 27 | 12 | Non Schedule Items S/E of 45 W LED Street light fitting < 100 Lumens per Watt Bajaj/ Halonix/ HPL make in aluminum pressure die casting housing toughened glass cover with IP-66 protection With Lense and dual surge protection device internal 5 KV and external 10 KV including all petty material with labour for errection, complete in all respect of Engineer-in-Charge of the work. | BI01010001010000000000000515BI0100001139 | 20 | Each |
| 28 | 13 | S/E of 60 W LED Flood light luminaries with high power LED 110 Lumens per Watt Bajaj/ Halonix/ HPL make in aluminum pressure die casting housing toughened glass cover with IP-66 protection With Lense and dual surge protection device internal 5 KV and external 10 KV including all petty material with labour for errection, complete in all respect of Engineer-in-Charge of the work. | BI01010001010000000000000515BI0100001140 | 16 | Each |
| 29 | 14 | S/E of 18 W indoor LED Tube fitting with batten and tube, decorative ultra slim liniare LED lighting fixture with extruded poly carbonate, environmental friendly, energy effiecent completed including all petty material with labour for errection, complete in all respect of Engineer-in-Charge of the work. (Make:- Philips/ Havell's/ Crompton/ HPL/ Halonix) | BI01010001010000000000000515BI0100001141 | 120 | Each |
| 30 | 15 | Supply and erection of 48\" AC Ceiling fan without regulator complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. Bajaj / Orient/ Khaitan. | BI01010001010000000000000515BI0100001142 | 60 | Each |
AI Tender Summary
Tender Timeline
May 18, 2020
11:30 IST
Tender Published
Tender notice published.
CompletedMay 28, 2020
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedMay 29, 2020
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender