}

Operation , Maintenance , Repairs And Replacement For Electrical And Mechanical Equipment To 147 Mld Capacity Raw Water Pumping Station At Mohone And Pure Water Treatment Plant At Barave For The Period Of Two Year . , Kalyan Dombivli Municipal Corporation area-Maharashtra

Kalyan Dombivli Municipal Corporation has published Operation , Maintenance , Repairs And Replacement For Electrical And Mechanical Equipment To 147 Mld Capacity Raw Water Pumping Station At Mohone And Pure Water Treatment Plant At Barave For The Period Of Two Year . . Submission Date for this Tender is 08-06-2020. Electromechanical Work Tenders in Kalyan Dombivli Municipal Corporation area Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

24331414
Corrigendum : Operation , Maintenance , Repairs And Replacement For Electrical And Mechanical Equipment To 147 Mld Capacity Raw Water Pumping Station At Mohone And Pure Water Treatment Plant At Barave For The Period Of Two Year .
Tender
Indian
Maharashtra
Kalyan Dombivli Municipal Corporation Area
08-06-2020

Tender Details

Operation , Maintenance , Repairs And Replacement For Electrical And Mechanical Equipment To 147 Mld Capacity Raw Water Pumping Station At Mohone And Pure Water Treatment Plant At Barave For The Period Of Two Year . , Item No . :-1Operation , Maintenance , Repairs & Replacement For Electrical & Mechanical Equipment , To Operate 147 Mld Capacity Water Works Of Barave Water Treatment Plant At Barave & Water Head Works At Mohane Including All Spare Parts , Labour For Operating 24 X 7 , Repair / Replacement Within Stipulated Time Period , Day To Day Maintenance Of Machinery , Cost Of All Labour , Material Etc . As Directed By The Engineer Incharge . Under This Item The Work Of Operation ( Including Raw Water Pumps , Chemical Dosing , Washing Of Filters , Testing Of Water As Per Norms & Pure Water , Wash Water , Recirculation Pumps Etc . ) , Periodical & Routine Maintenance & Repair Of Electrical & Mechanical Equipments With Material , , Reguler Cleaning ( Raw Water Chanel , Raw Water Sum , Areation Fountain , Clarifacculetor , Filters , Recirculation Well , Chlorine Contact Tank & Pure Water Sump , Sweeping & Keep Clean The Premises Of Raw Water Pump House & Barve Wtp . , Item No . 2Overhauling With Repairing 1250 Kva /1600 Kva Transformer: Dismantling The Existing 1250 / 1600 Kva , 22 Kv/0 . 433 Kv Crompten Greaves Make On Load Tap Changer Type Transformer By Means Of Hydra/ Crane Of Suitable Capacity , Cleaning All Healthy Parts , Laminations ( In Assembly ) , Tank , Insulating Sleeves Etc . Overhauling The Transformer With Replacement Of Damaged Parts And Rewound Coils And Reassembling Of Top Yoke Including Brazing , Soldering , Sleeving And Insulating As Required , Vacuum Oven Drying Of Assembled Core . Reassembling Of Complete Transformer By Tanking The Dried Core , Cleaning All Gaskets , Making Terminal Connections , Oil Filling , Filtration , Rewinding Of Hv & Lv Coils , Using New Copper Coil With New Insulation Including Internal & External Painting Of Transformer With Rebate For Damaged Material , To & Fro Transportation Charges Loading/ Unloading Making Connections With All Required Materials , Testing , Commissioning With Six Month Guarantee Etc Complete . , Item No . 3Overhauling With Repairing 500 Kva Transformer: Dismantling The Existing 500 Kva , 22 Kv/0 . 433 Kv Volt Amps Make Off Load Tap Chane Type Transformer By Means Of Hydra/ Crane Of Suitable Capacity , Cleaning All Healthy Parts , Laminations ( In Assembly ) , Tank , Insulating Sleeves Etc . Overhauling The Transformer With Replacement Of Damaged Parts And Rewound Coils And Reassembling Of Top Yoke Including Brazing , Soldering , Sleeving And Insulating As Required , Vacuum Oven Drying Of Assembled Core . Reassembling Of Complete Transformer By Tanking The Dried Core , Cleaning All Gaskets , Making Terminal Connections , Oil Filling , Filtration , Rewinding Of Hv & Lv Coils , Using New Copper Coil With New Insulation Including Internal & External Painting Of Transformer With Rebate For Damaged Material , To & Fro Transportation Charges Loading/ Unloading Making Connections With All Required Materials , Testing , Commissioning With Six Month Guarantee Etc Complete . , Item No . 4Overhauling With Repairing 1800 Kva Transformer: Dismantling The Existing 1800 Kva , 22 Kv/3 . 3 Kv Volt Amps Make Off Load Tap Chane Type Transformer By Means Of Hydra/ Crane Of Suitable Capacity , Cleaning All Healthy Parts , Laminations ( In Assembly ) , Tank , Insulating Sleeves Etc . Overhauling The Transformer With Replacement Of Damaged Parts And Rewound Coils And Reassembling Of Top Yoke Including Brazing , Soldering , Sleeving And Insulating As Required , Vacuum Oven Drying Of Assembled Core . Reassembling Of Complete Transformer By Tanking The Dried Core , Cleaning All Gaskets , Making Terminal Connections , Oil Filling , Filtration , Rewinding Of Hv & Lv Coils , Using New Copper Coil With New Insulation Including Internal & External Painting Of Transformer With Rebate For Damaged Material , To & Fro Transportation Charges Loading/ Unloading Making Connections With All Required Materials , Testing , Commissioning With Six Month Guarantee Etc Complete .

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 22-05-2020 Date Corregendum Date 30-05-2020
2 29-05-2020 Date Corregendum 2 Date 08-06-2020

Key Value

Document Fees
INR 2240 /-
EMD
INR 429900.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail