Housing Urban and Rular Development Government Departments Closing in 0 days TDR #24319405

Construction Of Double Storied School Building Of Sovapur Girls High School Under Sovapur Gp At Kathalia Rd Block , Sepahijala District , Tripura Under Pradhan Mantri Jan Vikas Krayakram Pmjvk Scheme During The Year 2019-20 Building Portion Including In

Issued by Government Departments · SONAMURA, Tripura
Tender Value
2.22 Crore
Estimated cost
Bid Submission
15 Jun 2020
0 days left
EMD
2.22 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
SONAMURA → Tripura
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of Double Storied School Building Of Sovapur Girls High School Under Sovapur Gp At Kathalia Rd Block , Sepahijala District , Tripura Under Pradhan Mantri Jan Vikas Krayakram Pmjvk Scheme During The Year 2019-20 Building Portion Including Internal Water Supply , Sanitary Installation , Sewage And Drainage Works .

BOQ

Name of Work : Construction of Double storied School Building of Sovapur Girls High School under Sovapur GP at Kathalia RD Block, Sepahijala District, Tripura under Pradhan Mantri Jan Vikas Krayakram (PMJVK) Scheme during the year 2019-20/S.H. Building portion including internal water supply, Sanitary installation, Sewage and Drainage works.
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11SUB-HEAD : EARTH WORKBI01010001010000000000000515BI0100001112
21.1Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.\n - All kinds of soilBI01010001010000000000000515BI01000011131087.77Cum
31.2Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.\n - All kinds of soilBI01010001010000000000000515BI0100001114117.6Cum
41.3Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.\n - All kinds of soilBI01010001010000000000000515BI0100001115803.58Cum
51.4Extra for additional lift of 1.5m or part thereof\n - All kinds of soilBI01010001010000000000000515BI0100001116803.58Cum
61.5Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete.BI01010001010000000000000515BI010000111782.94Cum
71.6Supplying chemical emulsion in sealed containers including delivery as specified.BI01010001010000000000000515BI0100001118
81.61(i) Chlorpyriphos/Lindane emulsifiable concentrate of 20%BI01010001010000000000000515BI0100001119179.01Litre
91.7Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment as per IS: 6313 (Part III)- Latest revision (excluding the cost of chemical emulsion):BI01010001010000000000000515BI0100001120
101.71(i) Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres/sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete:\n - With Chlorpyriphos/Lindane E.C. 20% with 1% concentration.BI01010001010000000000000515BI010000112167.2Metre
111.8Treatment of soil under plinth filling using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with sand filling:BI01010001010000000000000515BI0100001122
121.81(i) With Chlorpyriphos/Lindane E.C. 20% with 1% concentration.BI01010001010000000000000515BI0100001123448.29Sqm
132SUB-HEAD : CEMENT CONCRETE WORKBI01010001010000000000000515BI0100001124
142.1Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering\n - All work upto plinth level.BI01010001010000000000000515BI0100001125
152.11(i) 1:4:8 ( 1 Cement: 4 fine sand : 8 graded stone aggregate 40 mm nominal size)BI01010001010000000000000515BI010000112679.27Cum
162.22(ii) 1:2:4 ( 1 Cement: 2 fine sand : 4 graded stone aggregate 20 mm nominal size)BI01010001010000000000000515BI01000011274.206Cum
172.23(iii) 1:3:6 ( 1 Cement: 3 fine sand : 6 graded stone aggregate 20 mm nominal size)BI01010001010000000000000515BI010000112816.8Cum
182.3Centering shuttering including struttings, propping etc. and removal of form work for:\n(i) Foundations, footings, bases for columns.BI01010001010000000000000515BI010000112960.39Sqm
192.4Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specificationBI01010001010000000000000515BI0100001131179.28per 50kg\n of Cement
202.5Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 fine sand : 6 graded well burnt brick aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.BI01010001010000000000000515BI0100001132114.7Sqm
213SUB-HEAD : RCC WORKBI01010001010000000000000515BI0100001133
223.1Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement-\n -All work upto plinth level:BI01010001010000000000000515BI0100001134
233.11(i) 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size)BI01010001010000000000000515BI0100001135201.079Cum
243.2Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement-BI01010001010000000000000515BI0100001136
253.21(i) 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size)BI01010001010000000000000515BI010000113749.31Cum
263.3Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement-BI01010001010000000000000515BI0100001138
273.31(i) 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size)BI01010001010000000000000515BI0100001139241.48Cum
283.4Reinforced cement concrete work in vertical and horizontal fins individually or forming box louvers, facias and eaves boards above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement withBI01010001010000000000000515BI0100001140
293.41(i) 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size)BI01010001010000000000000515BI01000011414.6Cum
303.5Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.BI01010001010000000000000515BI0100001142
313.51(i) Thermo-Mechanically Treated bars of grade Fe-500D or moreBI01010001010000000000000515BI010000114331832.2Kg.
323.6Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.BI01010001010000000000000515BI0100001144
333.61(i) Thermo-Mechanically Treated bars of grade Fe-500D or moreBI01010001010000000000000515BI010000114545356.9Kg.
343.7Providing precast cement concrete Jali 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centring and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3(1cement : 3 fine sand) etc. complete, excluding the plastering of jambs, sills and soffitsBI01010001010000000000000515BI0100001146
353.71(i) 50 mm thickBI01010001010000000000000515BI01000011471.08Sqm.
363.8Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size).BI01010001010000000000000515BI01000011481.5Cum
373.9Centering shuttering including struttings, propping etc. and removal of form work for:BI01010001010000000000000515BI0100001149
383.91(i) Foundations, footings, bases for columns etc. for mass concrete with timber plankBI01010001010000000000000515BI0100001150222.32Sqm
393.92(ii) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. using shuttering plyBI01010001010000000000000515BI010000115187.6Sqm
403.93(iii) Suspended floors, roofs, landings, balconies and access platform with 12 mm thick shuttering plyBI01010001010000000000000515BI0100001152970.31Sqm
413.94(iv) Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering plyBI01010001010000000000000515BI0100001153973.68Sqm
423.95(v) Columns, Pillars, Piers, Abutments, Posts and Struts with shuttering plyBI01010001010000000000000515BI0100001154495.95Sqm
433.96(vi) Stairs (excluding landings) except spiral-staircases with wooden plankBI01010001010000000000000515BI010000115566.54Sqm
443.97(vii) Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards.BI01010001010000000000000515BI0100001156205.6Sqm
453.98(viii) Edges of slabs and breaks in floors and walls under 20 cm. wideBI01010001010000000000000515BI0100001157248Metre
463.99(ix) Weather shade, Chajjas, corbels etc., including edges.BI01010001010000000000000515BI010000115853.4Sqm
474SUB-HEAD : BRICK WORKBI01010001010000000000000515BI0100001159
484.1First class brick work in foundation and plinth including cost of all materials as required complete.BI01010001010000000000000515BI0100001160
494.11(i) In cement mortar 1:4 ( 1 cement : 4 fine sand ).BI01010001010000000000000515BI010000116141.95Cum
504.12(ii) In cement mortar 1:6 ( 1 cement : 6 fine sand ).BI01010001010000000000000515BI010000116244.64Cum
514.2First class brick work in superstructure above plinth level & upto floor-five level including cost of all materials as required complete.BI01010001010000000000000515BI0100001163
524.21(i) In cement mortar 1:6 ( 1 cement : 6 fine sand ).BI01010001010000000000000515BI0100001164106.1Cum
534.3Half brick masonry with first class bricks in superstructure upto floor five level including cost of all materials as required complete:-BI01010001010000000000000515BI0100001165
544.31(i) In cement mortar 1:4 ( 1 cement : 4 fine sand).BI01010001010000000000000515BI0100001166505.15Sqm.
554.4Extra for providing & placing in position 2 nos 6mm dia MS bars at every 4th course of half brick masonry work including anchorage in joints of 75mm in each side in superstructure for all level including cost of all materials as required complete:-BI01010001010000000000000515BI0100001167
564.41(i) In cement mortar 1:4 ( 1 cement : 4 fine sand ).BI01010001010000000000000515BI0100001168505.15Sqm.
575SUB-HEAD : WOOD WORKBI01010001010000000000000515BI0100001169
585.1Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position :BI01010001010000000000000515BI0100001170
595.11(i) Local Teak WoodBI01010001010000000000000515BI01000011712.81Cum
605.2Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veeners on both faces of shutters.BI01010001010000000000000515BI0100001172
615.21(i) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.BI01010001010000000000000515BI010000117372Sqm.
625.3Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete.BI01010001010000000000000515BI0100001174
635.31(i) Fixed to openings /wooden frames with rawl plugs screws etc.BI01010001010000000000000515BI01000011753237.6Kg.
645.4Providing 40 × 5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30 × 10 × 15 cm 1:3:6 mix (1 cement : 3 fine sand : 6 graded stone aggregate 20mm nominal size)BI01010001010000000000000515BI0100001176150No.
655.5Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :BI01010001010000000000000515BI0100001177
665.51(i) 300 x 16 mmBI01010001010000000000000515BI010000117821No.
675.52(ii) 250 x 16 mmBI01010001010000000000000515BI01000011794No.
685.6Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete :BI01010001010000000000000515BI0100001180
695.61(i) 300 x 10 mmBI01010001010000000000000515BI010000118110No.
705.62(ii) 250 x 10 mmBI01010001010000000000000515BI01000011828No.
715.7Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :BI01010001010000000000000515BI0100001183
725.71(i) 125 mmBI01010001010000000000000515BI010000118452No.
735.8Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete.BI01010001010000000000000515BI0100001185
745.81(i) Single rubber stopperBI01010001010000000000000515BI010000118636No.
755.9Providing and fixing factory made door frame (single rebate) made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 60mm width & 30mm thickness and shall be fixed to wall as per instructions of Engineer-In-Charge using 100x8 sheet metal CSK screws.BI01010001010000000000000515BI010000118730Metre
766.1Providing and fixing 28 mm thick door shutter made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 71mm width & 28mm thick as vertical & horizontal styles. Joints are made using solvent adhesive and GI ‘C sections (39mm x 19mm x 0.6mm thick) or M S pipe (40mm x 20mm ) stiffener frame insert & telescopic polymeric ‘L’ corners .The panel shall be filled with 3mm thick high - pressure compact laminate as per manufacturer’s specifications and directions of the Engineer-in-charge, cover moulding shall be provided for covering fixing screws and elegant look.( for W.C. bathroom door shutter).BI01010001010000000000000515BI01000011889.45Sqm.
776.2Providing and fixing IS : 3564 marked Aluminium die cast body tubular type universal hydraulic door closer with necessary accessories and screws etc. complete.BI01010001010000000000000515BI01000011894No.
787SUB-HEAD : STEEL WORKBI01010001010000000000000515BI0100001190
797.1Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm at 100 mm centre to centre and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia. steel pulleys & with riveted bolts, nuts, locking arrangement, stoppers, handles, hold fast /anchor bolt including embedding in cement concrete of required grade for fixing in position, all necessary fittings, including applying a priming coat of approved steel primer etc. complete as required.BI01010001010000000000000515BI010000119129.28Sqm.
807.2Providing and fixing fan clamp type-I of 16 mm dia M.S. bar bent to shape with hooked ends in R.C.C. slabs during laying including painting the exposed portion of loop, all as per standard design complete.BI01010001010000000000000515BI0100001192120Each
817.3Providing and fixing hand rail using structural steel etc. of approved size by welding etc. to steel ladder railing, balcony railing and staircase railing etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer complete as required:-BI01010001010000000000000515BI0100001193
827.31(i) M.S. tubeBI01010001010000000000000515BI0100001194120Kg.
837.4Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. complete as required:-BI01010001010000000000000515BI0100001195
847.41(i) In stringers, treads, landing etc. of stair cases including use of chequered plate wherever required, all complete.BI01010001010000000000000515BI0100001196375Kg.
857.5Providing and fixing M.S. round holding down bolts with nuts and wahser plates complete as per standard design.BI01010001010000000000000515BI010000119725Kg.
867.51Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).BI01010001010000000000000515BI010000119897.5Kg.
878SUB-HEAD : FLOORING AND SKIRTING WORKBI01010001010000000000000515BI0100001199
888.1Providing and laying ceramic floor tiles in different sizes (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 - 2017 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid over 20 mm thick cement mortar 1:4 (1 cement : 4 fine sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc. complete.\n - Mat Finish TilesBI01010001010000000000000515BI0100001200
898.11(i) Ceramic Tiles 1st quality 400 x 400mm in all shades and designsBI01010001010000000000000515BI0100001201528Sqm.
908.2Providing and fixing 1st quality ceramic glazed wall tiles (minimum 200 x 300) conforming to IS : 15622 - 2017 (thickness to be specified by the manufacturer) of approved make in all colours, shades of any size as approved by Engineer-in-charge in skirting, risers of steps and dados, laid over 12 mm thick bed of cement mortar 1 : 3 (1 cement : 3 fine sand) jointed with ordinary cement slurry including pointing with white cement mixed with pigment of matching shade complete.BI01010001010000000000000515BI0100001202132.78Sqm.
918.3Providing and fixing Kota stone in floors over 20 mm thick bed of cement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with ordinary cement slurry including pointing with ordinary cement mixed with pigment of matching shade, including rubbing and polishing complete.BI01010001010000000000000515BI0100001203
928.31(i) Kota stone slab 25mm thickBI01010001010000000000000515BI0100001204325.35Sqm
938.4Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1 : 3 ( 1 cement : 3 fine sand ) and joined with ordinary cement slurry mixed with pigment to match the shade of slabs, including rubbing and polishing complete.BI01010001010000000000000515BI010000120537.23Sqm
948.5Providing and laying cement concrete 1:2:4 (1 cement: 2 fine sand : 4 graded stone aggregate 20 mm nominal size) flooring finished with a floating coat of neat cement including cement slurry, rounding of edges and strips and cost of glass strips etc. complete.BI01010001010000000000000515BI0100001206
958.51(i) 40 mm thickBI01010001010000000000000515BI010000120737.5Sqm
968.6Providing and fixing precast chequered cement concrete tiles 18 mm thick, laid in footpath & courtyard, on 20 mm thick bed of cement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with neat cement slurry including rubbing and cleaning complete as per direction of the Engineer-in-Charge.BI01010001010000000000000515BI010000120866Sqm.
979SUB-HEAD : ROOFING AND CEILING WORKBI01010001010000000000000515BI0100001209
989.1Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kg/cm2) conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:BI01010001010000000000000515BI0100001210
999.11(i) Single socketed pipe - 110 mm ODBI01010001010000000000000515BI010000121191.8Metre
1009.2Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:BI01010001010000000000000515BI0100001212
1019.21(i) Coupler\n - 110mmBI01010001010000000000000515BI010000121312Each
1029.22(ii) Single equal tee without door\n - 110 x 110 x 110 mmBI01010001010000000000000515BI010000121412Each
1039.23(iii) Single equal tee with door\n - 110 x 110 x 110 mmBI01010001010000000000000515BI010000121512Each
1049.24(iv) Bend 87.5\n - 110mmBI01010001010000000000000515BI010000121612Each
1059.25(v) Plain shoe\n - 110 mmBI01010001010000000000000515BI010000121712Each
1069.3Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing with cement mortar 1 : 4 (1cement : 4 fine sand) making good the wall etc. complete.BI01010001010000000000000515BI0100001218
1079.31(i) 110mmBI01010001010000000000000515BI0100001219205Each
1089.4Providing and fixing to the inlet mouth of rain water pipe PTMT grating with thickness of 8mm and weighing not less than 100gm. complete.BI01010001010000000000000515BI0100001220
1099.41(i) 100mmBI01010001010000000000000515BI010000122112Each
11010SUB-HEAD : FINISHING WORKBI01010001010000000000000515BI0100001222
11110.112 mm cement plaster of mixBI01010001010000000000000515BI0100001223
11210.11(i) In cement mortar 1 : 4 (1 cement : 4 fine sand)BI01010001010000000000000515BI010000122457.44Sqm.
11310.12(ii) In cement mortar 1 : 6 (1 cement : 6 fine sand)BI01010001010000000000000515BI0100001225578.54Sqm.
11410.215 mm cement plaster on the rough side of single or half brick wall of mix.BI01010001010000000000000515BI0100001226
11510.21(i) In cement mortar 1 : 6 (1 cement : 6 fine sand)BI01010001010000000000000515BI0100001227676.12Sqm.
11610.36 mm cement plaster of mix:BI01010001010000000000000515BI0100001228
11710.31(i) In cement mortar 1 : 3 ( 1 cement : 3 fine sand )BI01010001010000000000000515BI01000012291697.99Sqm.
11810.4Neat cement punning.BI01010001010000000000000515BI010000123057.44Sqm.
11910.5Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :BI01010001010000000000000515BI0100001231
12010.51(i) New work ( two or more coats) over and including water thinnable priming coat with cement primer.BI01010001010000000000000515BI01000012322952.65Sqm.
12110.6Finishing walls with premium acrylic smooth exterior paint with Silicon additives of required shade of approved brand and manufacture [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :BI01010001010000000000000515BI0100001233
12210.61(i) New work ( two or more coats applied @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)BI01010001010000000000000515BI0100001234775.18Sqm.
12310.7Applying priming coat [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :BI01010001010000000000000515BI0100001235
12410.71(i) With ready mixed Pink or Grey primer of approved brand and manufacture on wood work ( hard & soft wood ).BI01010001010000000000000515BI0100001236162Sqm.
12510.72(ii) With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel worksBI01010001010000000000000515BI0100001237173.8Sqm.
12610.8Painting with synthetic enamel paint of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:BI01010001010000000000000515BI0100001238
12710.81(i) Two or more coats on new workBI01010001010000000000000515BI0100001239335.8Sqm.
12811SUB-HEAD : ALUMINIUM WORKBI01010001010000000000000515BI0100001240
12911.1Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixing with dash fasteners of required dia and size, including necessary filling up of gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawing and the direction of Engineer­in­charge. (Glazing and paneling and dash fasteners to be paid for separately) :-BI01010001010000000000000515BI0100001241
13011.11(i) For fixed portion of approved quality:-\n - Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15).BI01010001010000000000000515BI0100001242710.64Kg.
13111.2(ii) For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing fittings wherever required including the cost of EPDM rubber / neoprene gasket required ( Fittings shall be paid for separately ):-\n - Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15).BI01010001010000000000000515BI0100001243710.64Kg.
13211.3Providing and fixing glazing of approved quality in aluminium doors, windows, ventilator, shutters and partition etc. with EPDM rubber / neoprene gasket etc. complete as per architectural drawing and the direction of Engineer-in-charge (Cost of snap beading shall be paid in basic item) :-BI01010001010000000000000515BI0100001244
13311.31(i) With float glass panes of 4.0 mm thickness ( weight not less than 10.0 kg / sqm )BI01010001010000000000000515BI0100001245101.52Sqm.
13411.32(ii) With float glass panes of 5.5 mm thickness ( weight not less than 13.50 kg / sqm )BI01010001010000000000000515BI01000012466.4Sqm.
13511.4Providing and fixing stainless steel ( SS 304 grade ) adjustable friction window stay of approved quality with necessary stainless steel screws etc. to the side hung windows etc. complete as per direction of Engineer-in-charge:-BI01010001010000000000000515BI0100001247
13611.41(i) 255 x 19 mmBI01010001010000000000000515BI010000124848Each
13711.5Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. of approved quality complete as per direction of Engineer-in-charge:-BI01010001010000000000000515BI0100001249
13811.51(i) Anodised aluminium of grade AC 15 ).BI01010001010000000000000515BI010000125012Each
13912SUB-HEAD:WATER PROOFING WORKBI01010001010000000000000515BI0100001251
14012.1Grading roof for water proofing treatment complete as required as per direction of the Engineer-in-charge with :BI01010001010000000000000515BI0100001252
14112.11(i) Cement concrete 1:2:4 (1 cement : 2 fine sand : 4 graded stone aggregate 20 mm nominal size)BI01010001010000000000000515BI010000125322.41Cum
14213SUB-HEAD : SANITARY WORKSBI01010001010000000000000515BI0100001254
14313.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :BI01010001010000000000000515BI0100001255
14413.11(i) White Vitreous china Orrisa pattern W.C. pan of size 580x440 mm with integral type foot rests.BI01010001010000000000000515BI01000012563Each
14513.2Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :BI01010001010000000000000515BI0100001257
14613.21(i) W.C. pan with ISI marked white solid plastic seat and lidBI01010001010000000000000515BI01000012583Each
14713.3Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm sizes respectively.BI01010001010000000000000515BI01000012592Each
14813.4Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe.BI01010001010000000000000515BI01000012602Each
14913.5Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings:BI01010001010000000000000515BI0100001261
15013.51(i) Flat back wash basin of size 550x400mm.BI01010001010000000000000515BI01000012625Each
15113.6Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.BI01010001010000000000000515BI0100001263
15213.61(i) Semi rigid pipe\n - 32 mm diaBI01010001010000000000000515BI01000012645Each
15313.62(ii) Flexible pipe\n - 32 mm diaBI01010001010000000000000515BI01000012655Each
15413.7Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.BI01010001010000000000000515BI01000012665Each
15513.8Providing and fixing 600x120x5mm glass shelf with edges round of supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.BI01010001010000000000000515BI01000012675Each
15613.9Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colours weighing not less than 105 gms.BI01010001010000000000000515BI01000012685Each
15714.1Providing and fixing PTMT towel ring trapezoidal shape 215mm long, 200mm wide with a minimum distances of 37mm from wall face with concealed fittings arrangement of approved quality and colours weighing not less than 80 gms.BI01010001010000000000000515BI01000012695Each
15814.2Cutting chases in brick masonry walls for following diameter sand cast iron/centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size ) including necessary plaster and pointing in cement mortar 1:4(1cement: 4 coarse sand):BI01010001010000000000000515BI0100001270
15914.21(i) 100 mm dia.BI01010001010000000000000515BI01000012711.25Metre
16014.3Providing and fixing on wall face unplasticised Rigid PVC soil, waste & vent pipes (working pressure 6 kg / cm2) conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:BI01010001010000000000000515BI0100001272
16114.31(i) Single socketed pipe - 110 mm ODBI01010001010000000000000515BI010000127366Metre
16214.4Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC soil, waste & vent pipes pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:BI01010001010000000000000515BI0100001274
16314.41(i) Coupler\n - 110mmBI01010001010000000000000515BI010000127530Each
16414.42(ii) Single equal tee without door\n - 110 x 110 x 110 mmBI01010001010000000000000515BI010000127610Each
16514.43(iii) Single equal tee with door\n - 110 x 110 x 110 mmBI01010001010000000000000515BI010000127710Each
16614.44(iv) Bend 87.5\n - 110mmBI01010001010000000000000515BI010000127810Each
16714.45(v) Double equal junction of required degree without door\n - 110 mmBI01010001010000000000000515BI01000012795Each
16814.46(vi) Double equal junction of required degree with door\n - 110 mmBI01010001010000000000000515BI01000012805Each
16914.47(vii) Terminal guard:\n - 110 mmBI01010001010000000000000515BI01000012815Each
17014.5Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing with cement mortar 1 : 4 (1cement : 4 fine sand) making good the wall etc. complete.BI01010001010000000000000515BI0100001282
17114.51(i) 110mmBI01010001010000000000000515BI0100001283145Each
17215SUB-HEAD : WATER SUPPLYBI01010001010000000000000515BI0100001284
17315.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.\n - Concealed work including cutting chases and making good the walls etc.BI01010001010000000000000515BI0100001285
17415.11(i) 15 mm nominal outer dia pipesBI01010001010000000000000515BI010000128625Metre
17515.12(ii) 20 mm nominal outer dia pipesBI01010001010000000000000515BI010000128725Metre
17615.13(iii) 25 mm nominal outer dia pipesBI01010001010000000000000515BI010000128835Metre
17715.14(iv) 32 mm nominal outer dia pipesBI01010001010000000000000515BI010000128940Metre
17815.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge.BI01010001010000000000000515BI0100001290
17915.21(i) 20 mm nominal outer dia pipesBI01010001010000000000000515BI0100001291180Metre
18015.22(ii) 25 mm nominal outer dia pipesBI01010001010000000000000515BI0100001292180Metre
18115.23(iii) 40 mm nominal outer dia pipesBI01010001010000000000000515BI0100001293160Metre
18215.3Providing and fixing brass bib cock of approved quality :BI01010001010000000000000515BI0100001294
18315.31(i) 15 mm nominal boreBI01010001010000000000000515BI010000129514Each
18415.4Providing and fixing brass stop cock of approved quality :BI01010001010000000000000515BI0100001296
18515.41(i) 15 mm dia nominal boreBI01010001010000000000000515BI010000129756Each
18615.5Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end):BI01010001010000000000000515BI0100001298
18715.51(i) 25 mm nominal boreBI01010001010000000000000515BI01000012993Each
18815.52(ii) 40 mm nominal boreBI01010001010000000000000515BI01000013003Each
18915.6Providing and fixing gun metal non-return valve of approved quality (screwed end):BI01010001010000000000000515BI0100001301
19015.61(i) 25 mm nominal bore\n - VerticalBI01010001010000000000000515BI01000013023Each
19115.62(ii) 40 mm nominal bore\n - VerticalBI01010001010000000000000515BI01000013033Each
19215.7Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.BI01010001010000000000000515BI01000013042000Per Litre
19315.8Constructing masonry Chamber 30x30x50 cm, inside , in brick work in cement mortar 1:4 (1 cement :4 fine sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement :5 fine sand:10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement :3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design :BI01010001010000000000000515BI0100001305
19415.81(i) With Second Class bricksBI01010001010000000000000515BI010000130660Each
19515.9Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet:BI01010001010000000000000515BI0100001307
19615.91(i) 100 mm diameterBI01010001010000000000000515BI01000013085Each
19716SUB-HEAD : SEWAGE AND DRAINAGE WORKSBI01010001010000000000000515BI0100001309
19816.1Providing, laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture of cement mortar in the of 1:1 (1 cement: 1 fine sand) including testing of joints etc. complete :BI01010001010000000000000515BI0100001310
19916.11(i) 150 mm diameterBI01010001010000000000000515BI010000131140Metre
20016.2Providing and laying cement concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) alround S.W. pipes including bed concrete as per standard design:BI01010001010000000000000515BI0100001312
20116.21(i) 150 mm diameter S.W, pipeBI01010001010000000000000515BI010000131340Metre
20216.3Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with well burnt 2nd class bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.BI01010001010000000000000515BI01000013141Each
20316.4Constructing brick masonry chamber for underground C.I. inspection chamber and bends with 1st class bricks in cement mortar 1:4 (1 cement : 4 fine sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1 cement :2 fine sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 fine sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :BI01010001010000000000000515BI0100001315
20416.41(i) Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets :BI01010001010000000000000515BI01000013166Each
20516.5Extra for depth beyond 450 mm of brick masonry chamber for underground C.I. inspection chamber with same specification as mentioned in item no 20.330 complete as per standard design :BI01010001010000000000000515BI0100001317
20616.51(i) For 500x700 mm sizeBI01010001010000000000000515BI01000013182Metre

AI Tender Summary

OUR REF NO 24319405
AUTHORITY Government Departments
TENDER VALUE 2.22 Crore
LAST DATE 15-06-2020
Authority
Authority Name Public Works Department
Work Description Construction Of Double Storied School Building Of Sovapur Girls High School Under Sovapur Gp At Kathalia Rd Block , Sepahijala District , Tripura Under Pradhan Mantri Jan Vikas Krayakram Pmjvk Scheme During The Year 2019-20 Building Portion Including Internal Water Supply , Sanitary Installation , Sewage And Drainage Works .
Basic Detail
Tender No CE/PWD/DNIT/ACE/Project Unit/01/2020-21
Bidding Type Tender
Location
City SONAMURA
State Tripura
Key Dates
Publish Date 14 May 2020
Submission Date 15 Jun 2020
Open Date 16 Jun 2020
Finance
Tender Value 2.22 Crore
Tender Fee 5000
EMD 2.22 Lakhs
Exemption Not Available
Document List
791AE4DC-AAAB-4A54-82FF-E33701851978.html
Tendernotice_1.pdf
BOQ_10184.xls
DNITACE01.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

May 14, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
Jun 15, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jun 16, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

791AE4DC-AAAB-4A54-82FF-E33701851978.html

pdf

Tendernotice_1.pdf

xls

BOQ_10184.xls

pdf

DNITACE01.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders