| 1 | 1 | Disconnecting carefully electric connections, sealing of electric connections with adhesive tape and taking down unserviceable ceiling fan, exhaust fan, wall mounted fan, air circulator fan, pedestal fan of any size from ceiling or wall or the like and removing the same to MES storeyard complete all as specified and directed. | | 665 | Each |
|---|
| 2 | 2 | M & L for cutting and removing of burnt winding of the following fans motors of any make and Re-winding the same with appropriate guage super enamelled copper winding wire with and including necessary allied works such as insulation material, air drying insulation, varnishing, cotton tape lathered film paper, spacers, sleeves, replacement of bushes and bearings (if required after checking the same) and necessary testing and commissioning after re-assembling of fan complete all as specified and directed: - MAKE- Atlas, AGC, Precision Wires India Ltd. (MILAN), Perfect, Bharat Insulation Company Pvt. Ltd. | | | |
|---|
| 3 | 2.01 | (a) Ceiling fan 1200 mm sweep. | | 345 | Each |
|---|
| 4 | 2.02 | (b) Ceiling fan 1400 mm sweep. | | 200 | Each |
|---|
| 5 | 2.03 | (c) Exhaust fan 230 to 300 mm sweep. | | 30 | Each |
|---|
| 6 | 2.04 | (d) Exhaust fan 350 to 380 mm sweep. | | 25 | Each |
|---|
| 7 | 2.05 | (e) Exhaust fan 400 to 450 mm sweep. | | 15 | Each |
|---|
| 8 | 2.06 | (f) Flame proof Exhaust fan 300 to 350 mm sweep. | | 10 | Each |
|---|
| 9 | 2.07 | (g) Wall mounted fan 400 to 450 mm sweep. | | 20 | Each |
|---|
| 10 | 2.08 | (h) Flame proof wall mounted fan 400 to 450 mm sweep. | | 10 | Each |
|---|
| 11 | 2.09 | (j) Air circulator fan or pedestal fan upto 600 mm sweep. | | 5 | Each |
|---|
| 12 | 2.1 | (k) Flame proof air circulator fan or pedestal fan upto 600 mm sweep. | | 5 | Each |
|---|
| 13 | 3 | M & L for servicing and overhauling the following fans including cleaning with cleaning agent, greasing, replacement of bushes, capacitor, bearings etc. (if required), replacing the split pins, tightening the nut-bolts, screws etc. and making electric connections complete all as specified and directed: - NOTE FOR ITEM NO. 2.00 AND 3.00: - Ball bearing, Bushes and capacitor shall be measured and paid separately under respective item of this Schedule as 'Supply Only'. Repair and serving work to be carried out in the storeyard or in office premises under the close supervision of the executives. Cost of required T&P and Machinery required for execution of these items shall deemed included in the quoted rates. | | | |
|---|
| 14 | 3.01 | (a) Ceiling fan 1200 mm sweep. | | 350 | Each |
|---|
| 15 | 3.02 | (b) Ceiling fan 1400 mm sweep. | | 200 | Each |
|---|
| 16 | 3.03 | (c) Exhaust fan 230 to 300 mm sweep. | | 25 | Each |
|---|
| 17 | 3.04 | (d) Exhaust fan 350 to 380 mm sweep. | | 20 | Each |
|---|
| 18 | 3.05 | (e) Exhaust fan 400 to 450 mm sweep. | | 15 | Each |
|---|
| 19 | 3.06 | (f) Flame proof Exhaust fan 300 to 350 mm sweep. | | 5 | Each |
|---|
| 20 | 3.07 | (g) Wall mounted fan 400 to 450 mm sweep. | | 10 | Each |
|---|
| 21 | 3.08 | (h) Flame proof wall mounted fan 400 to 450 mm sweep. | | 5 | Each |
|---|
| 22 | 3.09 | (j) Air circulator fan or pedestal fan upto 600 mm sweep. | | 5 | Each |
|---|
| 23 | 3.1 | (k) Flame proof air circulator fan or pedestal fan upto 600 mm sweep. | | 5 | Each |
|---|
| 24 | 4 | Supply only the following spares of fans any type, make and sweep, replaced vide item No. 2.00 and 3.00 of this schedule complete all as specified and directed: - | | | |
|---|
| 25 | 4.01 | (a) Ball bearing 6201. MAKE- SKF, NBC, NSK, NACHI. | | 150 | Each |
|---|
| 26 | 4.02 | (b) Ball bearing 6202. MAKE- SKF, NBC, NSK, NACHI. | | 150 | Each |
|---|
| 27 | 4.03 | (c) Ball bearing 6203. MAKE- SKF, NBC, NSK, NACHI. | | 150 | Each |
|---|
| 28 | 4.04 | (d) Gun metal Bush any type as required. | | 150 | Each |
|---|
| 29 | 4.05 | (e) Capacitor 2.50 MFD, 50 Hz. MAKE- Epcos, Tibcon, Havells, Crompton. | | 200 | Each |
|---|
| 30 | 4.06 | (f) Capacitor 4.00 MFD, 50 Hz. MAKE- Epcos, Tibcon, Havells, Crompton. | | 150 | Each |
|---|
| 31 | 5 | S & F as in replacement heavy duty rubber reel suitable for hanging rod of ceiling fan complete all as specified and directed. | | 200 | Each |
|---|
| 32 | 6 | S & F as in replacement PVC 2 pole connector with fixing screws complete all as specified and directed. | | 200 | Each |
|---|
| 33 | 7 | S & F as in replacement mild steel holding clamp made of suitable size flat iron as in holding clamp of capacitor alongwith fixing screws as required complete all as specified and directed. | | 150 | Each |
|---|
| 34 | 8 | M & L for painting of complete exposed surface of fan any type, size and sweep including fan blades etc. with 02 coats of synthetic enamel paint of existing shade by means of spray painting with and including filling of cavities with filler material and cleaning of all dust, oil etc. complete all as specified and directed. | | 75 | Each |
|---|
| 35 | 9 | S & F as in replacement rubber pad packing of capacitor complete all as specified and directed. | | 100 | Each |
|---|
| 36 | 10 | S & F as in replacement 0.50 Sqmm size twin core, PVC insulated copper conductor flexible cord cable as in electric connection of ceiling fan complete all as specified and directed. | | 750 | RM |
|---|
| 37 | 11 | S & F as in replacement heavy duty mild steel socket alongwith split pin, screws as required for coupling fan motor and hanging down rod of ceiling fan complete all as specified and directed. | | 100 | Each |
|---|
| 38 | 12 | S & F as in replacement fan regulator electronic, switch type, 230 volts complete all as specified and directed. MAKE- Anchor, Havells, Legrand. | | 150 | Each |
|---|
| 39 | 13 | S & F as in replacement fan regulator electronic, socket type, 230 volts complete all as specified and directed. MAKE- Anchor, Havells, Legrand. | | 125 | Each |
|---|
| 40 | 14 | S & F as in replacement modular type step fan regulator electronic, 120 Watt suitable for 2 modules complete all as specified and directed. MAKE- Anchor, Havells, Legrand. | | 100 | Each |
|---|
| 41 | 15 | S & F as in replacement ceiling rose surface bakelite, 65 X 50 mm, three terminals, PVC / polycarbonate insulated body complete all as specified and directed. | | 50 | Each |
|---|
| 42 | 16 | S & F as in replacement sheet metal enclosure with socket plug top and MCB single pole and neutral enclosure with a two pin and earth plug and socket complete with one No. single pole MCB 20 Ampere capacity 240 Volts complete all as specified and directed. | | 25 | Each |
|---|
| 43 | 17 | S & F as in replacement ‘U’ clamp including nut-bolt, washers, rubber reel, split pin and check nut etc. suitable for ceiling fan any size complete all as specified and directed. | | 35 | Each |
|---|
| 44 | 18 | S & F as in replacement down rod (Haging Rod) of following length fabricated out of 15 mm bore GI tubing duly threaded for check nut and drilling for split pin and U clamps as necesssary for ceiling fan any size complete all as specified and directed: - | | | |
|---|
| 45 | 18.01 | (a) 450 mm. | | 40 | Each |
|---|
| 46 | 18.02 | (b) Exc. 450 mm but not Exc. 1000 mm as ordered. | | 30 | Each |
|---|
| 47 | 19 | S & F as in replacement PVC three core flexible wire with copper conductor of size 23/0.0076 confirming to IS-434 from connector of ceiling, exhaust fan to the mains complete all as specified and directed. MAKE- Polycab, KEI, Havells. | | 150 | RM |
|---|
| 48 | 20 | S & F as in replacement of burnt out wire of sub main wiring, PVC insulated, PVC sheathed, 2.50 Sqmm size, single core, multi-stranded copper conductor cable (FRLS) complete all as specified and directed. MAKE- Polycab, KEI, Havells. | | 200 | RM |
|---|
| 49 | 21 | S & F as in replacement of burnt out wire of sub main wiring, PVC insulated, PVC sheathed, 4.00 Sqmm size, single core, multi-stranded copper conductor cable (FRLS) complete all as specified and directed. MAKE- Polycab, KEI, Havells. | | 200 | RM |
|---|
| 50 | 22 | S & F as in replacement of burnt out wire of sub main wiring, PVC insulated, PVC sheathed, 6.00 Sqmm size, single core, multi-stranded copper conductor cable (FRLS) complete all as specified and directed. MAKE- Polycab, KEI, Havells. | | 200 | RM |
|---|
| 51 | 23 | S & F as in replacement of burnt out wire of sub main wiring, PVC insulated, PVC sheathed, 10.00 Sqmm size, single core, multi-stranded copper conductor cable (FRLS) complete all as specified and directed. MAKE- Polycab, KEI, Havells. | | 50 | RM |
|---|
| 52 | 24 | Supply and fixing as in replacement, 300 mm sweep plastic body exhaust fan, 3 Star rating, single phase, 230 volts AC, 900 RPM complete with and including all accessories, mounting frame, louver shutter at the existing place of old exhaust fan, grouting of ragged bolts in wall as required for fixing of exhaust fan, frame, louvers and making new electric connection with three single core flexible copper conductor cable of size 1.50 Sqmm from ceiling rose to connector of exhaust fan complete all as specified and directed. MAKE- Havells, Orient, Bajaj, Usha. | | 10 | Each |
|---|
| 53 | 25 | Supply, installation, commissioning and testing of air turbo ventilator as in replacement of old unserviceable one, for hanger roof at a height of above 15.00 m comprising of the following specifications: - \n(a) Outer dia- 700 mm \n(b) Throat dia- 500 mm \n(c) Height- 460 mm \n(d) Vanes (blades)- 38 vanes, aluminium 0.50 mm thick \n(e) Top plate MOC - stainless steel 0.50 mm thick \n(f) Bearing -Twin sealed 6001 ZZ / 6003 ZZ bearing with self lubricating Duponent Zytel 101 L Polyamide 66 resin to ensure frictionless rotation even at lowest wind velocity \n(g) Centre shaft- 18 mm high carbon sheet zinc plated \n(h) Inner arms / outer arms- MS with Electro zinc Plating\n(j) Base plate.\n(Make- Swastik Turbo Air Ventilator, Delhi / Thakurala Enterprises, Delhi) | | 4 | Each |
|---|
| 54 | 26 | S & F of Raibex Plastic Security Seals, polypropylene, thickness - 0.50 centimeters, Overall Length is 25 cm, tensile strength - 15.00 kilograms, Cable Width 0.5 cm, Seal Locking width 1.6 cm, Cable Width / Dia 0.5 cm, tamper resistance and reliability complete all as specified and directed. | | 500 | Each |
|---|
| 55 | 27 | S & F of split pin of different dia and length as per site requirement complete all as specified and directed. | | 100 | Each |
|---|
| 56 | 28 | S & F of fixing screw suitable for fan blades as ordered as per sample complete all as specified and directed. | | 100 | Each |
|---|
| 57 | 29 | S & F as in replacement of worn out defective energy meters with new digital type, ISI marked, AC single phase static energy meter of accuracy class 1.0, 240 Volts, 50 Hz with Backlite LCD display of rating 5-30 Ampere of make Secure, L&T with and including deposition of old electric meters in MES storeyard complete all as specified and directed. | | 3 | Each |
|---|
| 58 | 30 | S & F as in replacement of worn out defective energy meters with new digital type, ISI marked, AC three phase static energy meter of accuracy class 1.0, 3 X 240 Volts, 50 Hz with Backlite LCD display of rating 5-30 Ampere of make Secure, L&T with and including deposition of old electric meters in MES storeyard complete all as specified and directed. | | 3 | Each |
|---|
| 59 | 31 | Taking down carefully electric geyser storage type, any capacity, after disconnecting all electric and water connections, from its position, opening of geyser tank after removing glass wool and taking out copper inner tank for rectifying the leakage by doing welding, brazing, soldering, replacement of worn out nut-bolts, washer as required and re-fixing the same after making it functional at its position including necessary testing complete all as specified and directed. NOTE: - The cost of welding / soldering material, nut-bolts, washers as required and tranportation charges shall deemed included in the unit rate. T&P as required shall be provided by the contractor and cost thereof deemed included in the quoted rate. | | 195 | Each Job |
|---|
| 60 | 32 | Supply and fixing as in replacement, brass water inlet and outlet assembly alongwith rubber gasket suitable for 25 Litres capacity electric driven water storage heater including provision of housing thermostat assembly, heating element fixing arrangement, nut-bolts and washers as required complete all as specified and directed. MAKE- Bajaj, Recold, Ditz, Shakti. | | 50 | Each |
|---|
| 61 | 33 | Supply and fixing as in replacement, brass water inlet and outlet assembly alongwith rubber gasket suitable for 50 Litres capacity electric driven water storage heater including provision of housing thermostat assembly, heating element fixing arrangement, nut-bolts and washers as required complete all as specified and directed. MAKE- Bajaj, Recold, Ditz, Shakti. | | 50 | Each |
|---|
| 62 | 34 | Supply and fixing as in replacement, thermostat swith suitable for electric geyser any capacity as per sample complete all as specified and directed. MAKE- Bajaj, Recold, Ditz, Shakti. | | 150 | Each |
|---|
| 63 | 35 | Supply and fixing as in replacement, heating element triangular type of capacity 1.50 KW complete all as specified and directed. MAKE- Dass Pass, Theeta, Airex. | | 150 | Each |
|---|
| 64 | 36 | Supply and fixing as in replacement, heating element round type of capacity 1.50 KW complete all as specified and directed. MAKE- Dass Pass, Theeta, Airex. | | 150 | Each |
|---|
| 65 | 37 | Supply and fixing as in replacement, heating element triangular type of capacity 2.00 KW complete all as specified and directed. MAKE- Dass Pass, Theeta, Airex. | | 100 | Each |
|---|
| 66 | 38 | Supply and fixing as in replacement, heating element round type of capacity 2.00 KW complete all as specified and directed. MAKE- Dass Pass, Theeta, Airex. | | 100 | Each |
|---|
| 67 | 39 | Supply and fixing as in replacement, pressure release valve, conforming to relevant IS, 15 mm size suitable to fix with 15 mm bore GI pipe complete all as specified and directed. | | 20 | Each |
|---|
| 68 | 40 | S & F as in replacement, 450 mm long heavy duty PVC connection having brass chromium plated connector at both ends suitable for 15 mm bore water supply line or stop valve complete all as specified and directed. MAKE- Prayag, Netco, Getco. | | 200 | Each |
|---|
| 69 | 41 | Supply and fixing as in replacement, indicating lamp single pole, AC 230 volts, round or rectagular shaped as required, suitable for electric geyser any capacity complete all as specified and directed. | | 50 | Each |
|---|
| 70 | 42 | S & F as in replacement, 450 mm long heavy duty chromium plated HOT water connection suitable for 15 mm bore water supply line or stop valve complete all as specified and directed. | | 50 | Each |
|---|
| 71 | 43 | Supply and fixing in replacement, MCB SPN 40 Ampere, 240 volts 'C' series complete all as specified and directed. MAKE- ABB, L&T, Havells. | | 25 | Each |
|---|
| 72 | 44 | Supply and fixing in replacement, MCB DB 2 way single door including necessary fixing arrangement complete all as specified and directed. MAKE- Havells, L&T, ABB. | | 20 | Each |
|---|
| 73 | 45 | Supply and fixing in replacement, thermal cut out Bimetallic disc type alongwith snap action switch, with operator below the boiling point i.e. 90+ 6°C with manual reset knob for Geyser complete all as specified and directed. MAKE- Bajaj, Recold, Ditz, Shakti. | | 20 | Each |
|---|
| 74 | 46 | Supply and fixing in replacement, metal plug top 15 Ampere capacity having 3 pins, 230 volts complete all as specified and directed. | | 20 | Each |
|---|
| 75 | 47 | Supply and fixing in replacement, work shop cable, copper Flexible 3 core of size 40/0.0076 complete all as specified and directed. MAKE- Havells, Finolex, Plaza. | | 200 | RM |
|---|
| 76 | 48 | Supply and fixing in replacement, work shop cable, copper Flexible 3 core of size 70/0.0076 complete all as specified and directed. MAKE- Havells, Finolex, Plaza. | | 150 | RM |
|---|
| 77 | 49 | Supply and fixing in replacement, plug top 15 Ampere capacity having 3 pins, 230 volts complete all as specified and directed. MAKE- Anchor, Havells, Plaza | | 50 | Each |
|---|
| 78 | 50 | Supply and fixing in replacement, (MFV) valve alongwith necessary fixing arrangement suitable for Geyser of 25 Litres capacity complete all as specified and directed. MAKE- PEARL. | | 20 | Each |
|---|
| 79 | 51 | Supply and fixing in replacement, fusible plug complete all as specified and directed. MAKE- PEARAL | | 20 | Each |
|---|
| 80 | 52 | Supply and fixing in replacement, NEON bulb suitable for Geyser of 25 Litres capacity complete all as specified and directed. MAKE- PEARL | | 20 | Each |
|---|
| 81 | 53 | Supply and fixing in replacement, clamps alongwith suitable size of nut-bolts and washers (150 mm Long) complete all as specified and directed. | | 25 | Each |
|---|
| 82 | 54 | Supply and fixing in replacement, half door set suitable for 25 Litres capacity Geyser complete all as specified and directed. MAKE- PEARL | | 20 | Each |
|---|
| 83 | 55 | Supply and fixing in replacement, rubber gasket heavy duty suitable for 25 Litres capacity Geyser complete all as specified and directed. MAKE- PEARL | | 25 | Each |
|---|
| 84 | 56 | Supply and fixing in replacement, mounting plate suitable for 25 Litres capacity Geyser complete all as specified and directed. MAKE- PEARL | | 25 | Each |
|---|
| 85 | 57 | Supply and Fixing of glass wool suitable for water storage geyser of any capacity complete all as specified and directed. | | 20 | Kg |
|---|
| 86 | 58 | S & F as in replacement, 1100 volts grade heavy duty two single core 4.00 Sqmm size, PVC insulated (FRLS) copper multi-stranded conductor cable as in sub main wiring, drawn into & including PVC conduit medium grade not less than 25 mm dia including its all accessories & fittings, fixed concealed with and including chase cutting and making good the same as per existing specifications along with a continuous run of 2.50 Sqmm size multi-stranded copper conductor PVC insulated (FRLS) (green colour) cable as earth wire complete all as specified and directed. | | 250 | RM |
|---|
| 87 | 59 | S & F as in replacement, 1100 volts grade heavy duty two single core 6.00 Sqmm size, PVC insulated (FRLS) copper multi-stranded conductor cable as in sub main wiring, drawn into & including PVC Caping-N-Caping medium grade not less than 20 mm dia including its all accessories & fittings, fixed on surface along with a continuous run of 4.00 Sqmm size multi-stranded copper conductor PVC insulated (FRLS) (green colour) cable as earth wire complete all as specified and directed. | | 200 | RM |
|---|
| 88 | 60 | Servicing and maintnance of Solar water heater system of capacity 200 to 300 Litres including de-scaling with suitable good quality descaling chemical as approved by Engineer-in-Charge for minimum 5 hours running of descaling liquid with suitable pump, motors, connections etc., cleaning of water tank, cleaning of pipe, Air vent, eliminator etc. and re-fixing the same at its original positions to make solar water heater functional complete all as specified and directed. NOTE: Spare parts shall be measured and paid separately under respective items of this schedule. | | 30 | Each Job |
|---|
| 89 | 61 | S & F as in replacement, following fittings or spare parts suitable for Solar water heater of capacity 200 to 300 Litres complete all as specified and directed: - | | | |
|---|
| 90 | 61.01 | (a) Automatic Air vent. | | 4 | Each |
|---|
| 91 | 61.02 | (b) Copper pipe insulation. | | 40 | RM |
|---|
| 92 | 61.03 | (c) Air-eliminator. | | 3 | Each |
|---|
| 93 | 61.04 | (d) Fill / drain assembly. | | 5 | Each |
|---|
| 94 | 61.05 | (e) Element of 3 KW capacity. | | 4 | Each |
|---|
| 95 | 61.06 | (f) Solar water heater tank of 300 Litres capacity. | | 3 | Each |
|---|
| 96 | 61.07 | (g) Collector Temperature sensor. | | 5 | Each |
|---|
| 97 | 61.08 | (h) Shut off valve. | | 3 | Each |
|---|
| 98 | 61.09 | (j) Evacuated Copper Tube Solar Collector. | | 3 | Each |
|---|
| 99 | 61.1 | (k) Solar Water Heater Glass Tubes. | | 10 | Each |
|---|
| 100 | 62 | Repair to unserviceable Air Turbo Ventilator by taking out the same from the roof of Hangers at a height of more than 15.00 Metres, dismantling of parts for its checking and replacement of burn out bearings by providing new bearings of existing type and number, re-assembling of complete ventilator and re-fixing the same on roof after making in serviceable condition complete as specified and directed. | | 5 | Each |
|---|
| 101 | 63 | Repair to unserviceable Air Turbo Ventilator by taking out the same from the roof of Hangers at a height of more than 15.00 Metres, dismantling of parts for its checking and replacement of rusted or broken base plate by providing new base plate of existing type and pattern, re-assembling of complete ventilator and re-fixing the same on roof after making in serviceable condition complete as specified and directed. | | 4 | Each |
|---|