Re-Tender-Icar Dg 2018-19-Construction Of New Girls Hostel At Covas , Mannuthy - Electrification
Tender Value
8.83 Lakhs
Estimated cost
Bid Submission
21 May 2020
0 days left
EMD
22100
Bank guarantee accepted
Document Fee
1998
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Mannuthy → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Re-Tender-Icar Dg 2018-19-Construction Of New Girls Hostel At Covas , Mannuthy - Electrification
BOQ
| Name of Work: : ICAR DG-2018-19-Construction of new Girls Hostel at CoVAS,Mannuthy-Electrification | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | 1.10.2 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group B | BI01010001010000000000000515BI0100001107 | 40 | Point |
| 2 | 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C | BI01010001010000000000000515BI0100001108 | 130 | Point |
| 3 | 3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required\n2x1.5 sq.mm + 1x1.5 sq.mm earth wire | BI01010001010000000000000515BI0100001109 | 1000 | One metre |
| 4 | 4 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required\n2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | BI01010001010000000000000515BI0100001110 | 450 | One metre |
| 5 | 5 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required\n2 X 4 sq. mm + 1 X 4 sq. mm earth wire | BI01010001010000000000000515BI0100001111 | 30 | One metre |
| 6 | 6 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required\n4 X 6 sq. mm + 2 X 6 sq. mm earth wire | BI01010001010000000000000515BI0100001112 | 30 | One metre |
| 7 | 7 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.\n5/6 amps switch | BI01010001010000000000000515BI0100001113 | 230 | Each |
| 8 | 8 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.\n3 pin 5/6 amp socket outlet | BI01010001010000000000000515BI0100001114 | 85 | Each |
| 9 | 9 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.\n1 or 2 Module | BI01010001010000000000000515BI0100001115 | 32 | Each |
| 10 | 10 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.\n4 Module | BI01010001010000000000000515BI0100001116 | 4 | Each |
| 11 | 11 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.\n6 Module | BI01010001010000000000000515BI0100001117 | 6 | Each |
| 12 | 12 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.\n8 Module | BI01010001010000000000000515BI0100001118 | 32 | Each |
| 13 | 13 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.\n12 Module | BI01010001010000000000000515BI0100001119 | 8 | Each |
| 14 | 14 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). | BI01010001010000000000000515BI0100001120 | 42 | Each |
| 15 | 15 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. | BI01010001010000000000000515BI0100001121 | 12 | Each |
| 16 | 16 | Wiring indipentant (with out wire and pipe) | BI01010001010000000000000515BI0100001122 | 52 | Each |
| 17 | 17 | Wiring Combined | BI01010001010000000000000515BI0100001123 | 82 | Each |
| 18 | 18 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. | BI01010001010000000000000515BI0100001124 | 110 | Each |
| 19 | 19 | Supplying and fixing brass batten/ angle holder including connection etc. as required. | BI01010001010000000000000515BI0100001125 | 35 | Each |
| 20 | 20 | Supply and fixing of of CAT 6 UTP patch cord 2 meter\n(Dlink/AMP/equivalent) | BI01010001010000000000000515BI0100001126 | 4 | Each |
| 21 | 21 | Supply and fixing of 6 U network rack with cable manager and, mounting accessories (Dlink/AMP/equivalent) | BI01010001010000000000000515BI0100001127 | 1 | Each |
| 22 | 22 | Supply and fixing of of CAT 6 UTP patch cord 1 meter\n(Dlink/AMP/equivalent) | BI01010001010000000000000515BI0100001128 | 4 | Each |
| 23 | 23 | Supply of CAT 6 keystone information outlet port with dust shutter.\n(AMP/Dlink/equivalent) | BI01010001010000000000000515BI0100001129 | 4 | Each |
| 24 | 24 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required\n(AMP/Dlink/equivalent) | BI01010001010000000000000515BI0100001130 | 280 | One metre |
| 25 | 25 | Supply installation, testing and commissioning of patch panel | BI01010001010000000000000515BI0100001131 | 1 | Each |
| 26 | 26 | Supply installation, testing and commissioning of switch - 16 port | BI01010001010000000000000515BI0100001132 | 1 | Each |
| 27 | 27 | Supply and installation, testing and commissioning of internet access point at the hostel floors | BI01010001010000000000000515BI0100001133 | 2 | Each |
| 28 | 28 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required | BI01010001010000000000000515BI0100001134 | 4 | set |
| 29 | 29 | Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving earth connection as required.\n12 SWG bare Cu | BI01010001010000000000000515BI0100001135 | 80 | One metre |
| 30 | 30 | 6 Way, Vertical TPN DB - Conforms to IS 8623-1 & 3, IEC- 61439-1&3, Double door, made with CRCA sheet steel, RAL 9003, powder coated. Provided with insulated vertical phase bus-bars/neutral bars with shrouds/ earth bars/ sticking saddles/cement spill protector/color-coded interconnecting wire set/cable ties/and circuit identification labels. | BI01010001010000000000000515BI0100001136 | 1 | Each |
| 31 | 31 | 12 Way, TPN MCB DB- Conforms to IS 8623-1 & 3, IEC- 61439-1&3, Double door, made with CRCA sheet steel, RAL 9003, powder coated. Provided with insulated phase bus-bars/neutral bars with shrouds/ earth bars/ sticking saddles/cement spill protector/color-coded interconnecting wire set/cable ties/and circuit identification labels. Provision for SP MCB as outgoings - Supply, installation, testing and commissioning all complete. | BI01010001010000000000000515BI0100001137 | 2 | Each |
| 32 | 32 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator\n12 way, Double door | BI01010001010000000000000515BI0100001138 | 2 | Each |
| 33 | 33 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.\n63 amps | BI01010001010000000000000515BI0100001139 | 2 | Each |
| 34 | 34 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.\n100 amps | BI01010001010000000000000515BI0100001140 | 1 | Each |
| 35 | 35 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.\n40 amps | BI01010001010000000000000515BI0100001141 | 2 | Each |
| 36 | 36 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.\n63 amps | BI01010001010000000000000515BI0100001142 | 1 | Each |
| 37 | 37 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.\n40 amps | BI01010001010000000000000515BI0100001143 | 2 | Each |
| 38 | 38 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.\n25 amps | BI01010001010000000000000515BI0100001144 | 2 | Each |
| 39 | 39 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.\nSingle pole | BI01010001010000000000000515BI0100001145 | 38 | Each |
| 40 | 40 | Supply of 4C 16 sqmm XLPE armoured aluminium cable | BI01010001010000000000000515BI0100001146 | 24 | One metre |
| 41 | 41 | Supply of 4C 25 sqmm XLPE armoured aluminium cable | BI01010001010000000000000515BI0100001147 | 32 | One metre |
| 42 | 42 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.\nUpto 35 sq. mm (clamped with 1mm thick saddle) | BI01010001010000000000000515BI0100001148 | 56 | One metre |
| 43 | 43 | Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.\n4 X 16 sq. mm | BI01010001010000000000000515BI0100001149 | 4 | Each |
| 44 | 44 | Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.\n4 X 25 sq. mm | BI01010001010000000000000515BI0100001150 | 2 | Each |
| 45 | 45 | Supplying and fixing of following ways surface/recess mounting vertical type, 230V single phase, Energy meter box, vision panel, dust protected, sintex box, common neutral link, earth bar, 63A baklite fuse unit, HRC, 32A neutral link etc complete | BI01010001010000000000000515BI0100001151 | 1 | Each |
| 46 | 46 | Supply and fixing of 2 pole enclosure with 25A MCB for UPS OUT connection - supply, fixing, testing, commissioning all complete | BI01010001010000000000000515BI0100001152 | 1 | Each |
| 47 | 47 | Supply and fixing of 4 pole enclosure with 32A MCB for UPS IN connection - supply, fixing, testing, commissioning all complete | BI01010001010000000000000515BI0100001153 | 1 | Each |
| 48 | 48 | Providing, Installation, testing and commissioning of street light 25W LED (Philips, Bajaj, Luker or Equivalent) | BI01010001010000000000000515BI0100001154 | 2 | Each |
| 49 | 49 | S & F LED Bulb classic 9W on existing batten holder- Luker, Philips, Bajaj or equivalent brand | BI01010001010000000000000515BI0100001155 | 35 | Each |
| 50 | 50 | Supply of 20W LED Tube with fitting. Mushroom 20W all complete - Luker, Philips, Bajaj or equivalent brand | BI01010001010000000000000515BI0100001156 | 80 | Each |
| 51 | 51 | Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required. (HAVELLS, BAJAJ, CROMPTON, OREONT or equvalient) | BI01010001010000000000000515BI0100001157 | 20 | Each |
| 52 | 52 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. | BI01010001010000000000000515BI0100001158 | 20 | Each |
| 53 | 53 | Supply and installation of suitable size MS belt type fan clamp fabricated from MS flat (2 piece) as per IS 732 as required. | BI01010001010000000000000515BI0100001159 | 20 | Each |
| 54 | 54 | Supply and providing every additional length of down rod of suitable size heavy gauge GI / WI pipe with 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming in relevant ISS or with original wiring extended including painting as required. | BI01010001010000000000000515BI0100001160 | 16 | One metre |
| 55 | 55 | Supply, conveyance, installation, testing and commissioning of the following sizes of exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 crore round copper conductor flex wire conforming to relevant ISS - 305mm, single phase, heavy duty, 1400rpm exhaust fan in metal frame | BI01010001010000000000000515BI0100001161 | 16 | Each |
| 56 | 56 | Supply, conveyance, installation, testing and commissioning of the following sizes of exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 crore round copper conductor flex wire conforming to relevant ISS - 380mm, single phase, heavy duty, 1400rpm exhaust fan in metal frame | BI01010001010000000000000515BI0100001162 | 4 | Each |
| 57 | 57 | Supply and fixing of Bulk head including 7/9W LED bulb\n | BI01010001010000000000000515BI0100001163 | 8 | Each |
| 58 | 58 | Preparation of necessary forms and drawings to Electrical section Mannuthy for taking new 3phase electrical connection | BI01010001010000000000000515BI0100001164 | 1 | job |
AI Tender Summary
Tender Timeline
May 13, 2020
11:30 IST
Tender Published
Tender notice published.
CompletedMay 21, 2020
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedMay 25, 2020
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender