| 1 | 1 | Taking down carefully unserviceable/burnt copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators, socket etc to be measured separately), and keeping aside for taking in account of credit and making good disturbed surfaces of walls, floors etc all as specified | | 191 | Per Point |
|---|
| 2 | 2 | M&L for Point wiring complete with 1.5 sqmm single core PVC insulted FRLS cable 1100 volts grade with multistranded copper conductor drawn through and including 20mm dia PVC rigid non metallic PVC conduit with all accessories such as internal bend, end caps, etc complete fixed on walls/ceiling/roof/etc by means of suitable GI saddles/Spacers and including provision of 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor, fabricated steel terminal box made out of 1.6 mm thick MS sheet concealed in walls with 3mm thick bakelite top cover sheet, ISI maked with chromium plated screws and cup washers for housing the switches , socket outlets, fan regulators etc, all as specified and as directed for One light point controlled by one, one way switch all as specified | | 30 | Per point |
|---|
| 3 | 3 | All as per item No. 2 here in before but for One fan point controlled by one, one way switch and regulator. | | 10 | Per point |
|---|
| 4 | 4 | All as per item No. 2 here in before but for One switch socket outlet point controlled by one 06 Amp switch on independent board. | | 15 | Per point |
|---|
| 5 | 5 | All as per item No. 2 here in before but for One switch socket outlet point controlled by one 06 Amp switch on same board. | | 5 | Per point |
|---|
| 6 | 6 | All as per item No. 2 here in before but for One light point controlled by two way 2-switches 06 Amps. | | 2 | Per point |
|---|
| 7 | 7 | All as per item No. 2 here in before but for One call bell/buzzer point controlled by one bell push switch. | | 5 | Per point |
|---|
| 8 | 8 | All as per item No. 2 described here-in-before but with copper conductor cable FRLS 2.5 Sqmm for one 3 pin socket outlet, 16 Amps and including provision of FRLS 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor on independent board all as specified | | 20 | Per point |
|---|
| 9 | 9 | M&L for Point wiring complete with 1.5 sqmm single core PVC insulted FRLS cable 1100 volts grade with multistranded copper conductor drawn through in existing conduit including 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor, complete all as specified and as directed for One light point controlled by one, one way switch all as specified | | 35 | Per point |
|---|
| 10 | 10 | All as per item No. 9 here in before but for One fan point controlled by one, one way switch and regulator. | | 10 | Per point |
|---|
| 11 | 11 | All as per item No. 9 here in before but for One switch socket outlet point controlled by one 06 Amp switch on independent board. | | 20 | Per point |
|---|
| 12 | 12 | All as per item No. 9 here in before but for One switch socket outlet point controlled by one 06 Amp switch on same board. | | 5 | Per point |
|---|
| 13 | 13 | All as per item No. 9 here in before but for One light point controlled by two way 2-switches 06 Amps. | | 4 | Per point |
|---|
| 14 | 14 | All as per item No. 9 here in before but for One call bell/buzzer point controlled by one bell push switch. | | 5 | Per point |
|---|
| 15 | 15 | All as per item No. 9 described here-in-before but with copper conductor cable FRLS 2.5 Sqmm for one 3 pin socket outlet, 16 Amps and including of FRLS 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor on independent board all as specified | | 25 | Per point |
|---|
| 16 | 16 | Taking down carefully by unscrewing from boards/out let boxes, unserviceable accessories, fixtures such as modular/piano switches, sockets, ceiling rose, switch socket combinations, bell bush, calling bell, fan regulator, holders, modular/piano complete all as specified | | 855 | Each |
|---|
| 17 | 17 | Supply and fix holder PVC bakelite agngle/pendant with back plate all as specified and as directed. Make: Anchor, SSK, Cona. | | 25 | Each |
|---|
| 18 | 18 | Supply and fix switch Piano flush button single pole one way 06 A all as specified and as directed. Make: Anchor, SSK, Cona. | | 250 | Each |
|---|
| 19 | 19 | Supply and fix switch Piano flush button single pole one way 16 A all as specified and as directed. Make: Anchor, SSK, Cona. | | 25 | Each |
|---|
| 20 | 20 | Supply and fix switch socket combination 16 Amps flush type universal all as specified and as directed. Make: Anchor, SSK, Cona. | | 100 | Each |
|---|
| 21 | 21 | Supply and fix switch socket combination 06 amps flush type all as specified and as directed. Make: Anchor, SSK, Cona. | | 150 | Each |
|---|
| 22 | 22 | Supply and fix socket outlet piano, 5 pin 06 amps flush type all as specified and as directed. Make: Anchor, SSK, Cona | | 25 | Each |
|---|
| 23 | 23 | Supply and fix socket outlet piano, multi purpose two in one, 06 & 16 amps flush type all as specified and as directed. Make: Anchor, SSK, Cona. | | 25 | Each |
|---|
| 24 | 24 | Supply and fix switch Piano flush button two way 06 A all as specified and as directed. Make: Anchor, SSK, Cona. | | 10 | Each |
|---|
| 25 | 25 | S & F 100 watt, 230V, 50Hz electronic stepped type regulator (switch type size) suitable for ceiling fan. | | 25 | Each |
|---|
| 26 | 26 | All as per item No 25 but of socket type size. | | 20 | Each |
|---|
| 27 | 27 | Supply and fix bell push flush type 06 A all as specified and directed. Make: Anchor, SSK, Cona. | | 15 | Each |
|---|
| 28 | 28 | Supply and fix call bell , ding dong, electric AC 230Volt. Make: Anchor, SSK, Cona. | | 40 | Each |
|---|
| 29 | 29 | Supply and fix ceiling rose surface type bakelite 65 x 50mm with three terminals. | | 50 | Each |
|---|
| 30 | 30 | S&F modular switch 10A single pole, one way, 1 module, complete all as specified and as directed. Make: Anchor Roma Cat No. 21011, Cona Trump Cat No. 15001 or equivelent in Legrand, SSK. | | 30 | Each |
|---|
| 31 | 31 | S&F modular switch 20A, one way, 1 module complete all as specified and directed. Make: Anchor Roma Cat No. 21066, Cona Trump Cat No. 15051 or equivelent in Legrand, SSK. | | 20 | Each |
|---|
| 32 | 32 | S&F modular socket, 06A, 2 in 1, 2 module complete all as specified and as directed. Make: Anchor Roma Cat No. 30373, Cona Trump Cat No. 15091 or equivelent in Legrand, SSK. | | 15 | Each |
|---|
| 33 | 33 | S&F modular socket 06/16A, heavy duty 2 module. Make: Ancor Roma Cat No. 30828, Cona Trump, Cat No. 15101 or equivelent in Legrand, SSK. | | 10 | Each |
|---|
| 34 | 34 | S&F modular Fan step regulator, ISI marked - 2 module complete all as specified and as directed. Make: Ancor Roma Cat No. 20507, Cona Trump Cat No. 15126 or equivelent in Legrand, SSK. | | 15 | Each |
|---|
| 35 | 35 | S&F modular bell push 10A single pole one way, with neon, 1 module complete all as specified and as directed. Make: Ancor Roma Cat No. 21055, Cona Trump Cat No. 15021or equivelent in Legrand, SSK. | | 5 | Each |
|---|
| 36 | 36 | Taking down unserviceable submain wiring of any size including GI/Copper earth continuity conductor and conduit/batten on wall/roof etc and making good to disturbed surfaces.stracking for issue under credit | | 200 | RM |
|---|
| 37 | 37 | M&L for Sub main wiring complete with 2 runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade multistranded copper conductor cable with 01 run of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through in and including 25 mm or higher dia non metallic rigid PVC conduit and conduit accessories fixed on wall/Ceiling/Fixed to roof/truss etc all as specified and as directed. | | 50 | RM |
|---|
| 38 | 38 | All as per item No. 37 described here-in-before but 2 runs of 4 sqmm and one run of 4 sqmm as earth continuity conductor, drawn through in and including 25 mm or higher dia non metallic rigid PVC conduit and conduit accessories fixed on wall/Ceiling/Fixed to roof/truss etc all as specified and as directed. | | 50 | RM |
|---|
| 39 | 39 | M&L for Sub main wiring complete with 2 runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade multistranded copper conductor cable with 01 run of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through in existing conduit complete all as specified and as directed. | | 50 | RM |
|---|
| 40 | 40 | All as per item No. 39 described here-in-before but 2 runs of 4 sqmm and one run of 4 sqmm as earth continuity conductor, drawn through in existing conduit complete all as specified and as directed. | | 50 | RM |
|---|
| 41 | 41 | S&F in replacement Modular White cover plate with frame,2 module complete all as specified and as directed. Make: Ancor Roma, Cat No. 30227WH,Cona Trump Cat No. 15502 or equivelent in Legrand, SSK. | | 4 | Each |
|---|
| 42 | 42 | All as per item No.41 but 4 module. Make: Ancor Roma, Cat No. 30249WH ,Cona Trump Cat No. 15504 or equivelent in Legrand, SSK. | | 5 | Each |
|---|
| 43 | 43 | All as per item No.41 but 6 module. Make: Ancor Roma, Cat No. 30250WH, Cat No. Cona Trump Cat No. 15506 or equivelent in Legrand, SSK. | | 5 | Each |
|---|
| 44 | 44 | All as per item No.41 but 8 module. Make: Ancor Roma, Cat No. 30384WH, Cona Trump Cat No. 15508 or equivelent in Legrand, SSK. | | 5 | Each |
|---|
| 45 | 45 | All as per item No. 41 but 12 module. Make: Ancor Roma, Cat No. 30271WH, Cona Trump Cat No. 15512 or equivelent in Legrand, SSK. | | 5 | Each |
|---|
| 46 | 46 | S&F in repairs sheet metal enclosure with single pole and neutral enclosure with a two pin and earth plug and socket with one single pole MCB 20 Amps 240 Volts complete all as specified and as directed. | | 10 | Each |
|---|
| 47 | 47 | Taking down carefully old unserviceable light fittings any type size complete and making good the disturbed surface of wall , roof, ceiling etc complete all as specified and directed. | | 75 | Each |
|---|
| 48 | 48 | Supply and fix LED tube light fittings T8, batten type TARA-M/20 series with LED tube 1x20 Watt / 1x18 watt MS White powder coated decorative LET T8 batten with PC tube complete all as specified and directed. Make: C&S Cat No. LTDC01220WLED/WD with tube rod\nLuker Cat No. LLTS1 with LT1818 tube rod or equivalent in Crompton Greaves/ Havells.\n | | 25 | Each |
|---|
| 49 | 49 | Supply and integrated batten NAKSHATRA SERIES, 16 Watt T5 aluminium extruded LED integrated batten complete all as specified and directed. Make: C&S Cat No. LTTB4F16WLED/W \nLuker Cat No. LT520 with tube or equivalent in Crompton Greaves/ Havells.\n | | 25 | Each |
|---|
| 50 | 50 | Supply and fix LED tube light fittings T5 musroom set 10 Watt complete all as specified and directed.\nMake : Luker, Cat No. LT5M10 with tube rod, C&S Cat No. LTTB2F10WLED/W or equivalant in crompton greaves/Havells. | | 25 | Each |
|---|
| 51 | 51 | Supply and fix in replacement laminated sheet 4\" x 4\" complete all as specified and directed. | | 10 | Each |
|---|
| 52 | 52 | Supply and fix in replacement laminated sheet 7\" x6\" complete all as specified and directed. | | 10 | Each |
|---|
| 53 | 53 | Supply and fix in replacement laminated sheet 8\" x 10\" complete all as specified and directed. | | 10 | Each |
|---|
| 54 | 54 | Supply and fix in replacement laminated sheet 10\" x 12\" complete all as specified and directed. | | 10 | Each |
|---|
| 55 | 55 | Disconnecting electric connections and taking down carefully old unserviceable distribution boards (DBs) of any ways/size/capacity complete all as specified and directed. | | 6 | Each |
|---|
| 56 | 56 | Supply and fix sheet metal enclosure with distribution board (DB) 240 Volts SPN 08 way double door 200 Amps rated busbar fixed on wall and connecting with all as directed by Engineer in charge. Make: Indoasian, Havells, Standard. | | 3 | Each |
|---|
| 57 | 57 | Supply and fix sheet metal enclosure with distribution board (DB) 415 Volts SPN 12 way double door with 200 Amps rated busbar fixed on wall and connecting all as directed by Engineer in charge. Make: Indoasian, Havells, Standard. | | 1 | Each |
|---|
| 58 | 58 | Supply and fix DB E TPN DB Double door, 4 ways having IP:43 protection, Isolated neutral bar, door earthing, mechnical impact strength IK08, cement spil protection. Make: Indoasian Cat No. 811840 or equivelent in Standard, Havells, Schnieder. | | 2 | Each |
|---|
| 59 | 59 | Supply and fix MCB TPN 63 Amps, Curve \"B\" . Make: Indoasian Cat No. 811220 or equivelent in Standard, Havells, Schnieder. | | 5 | Each |
|---|
| 60 | 60 | S&F in replacement MCB SP 6-32 Amps 240 Volt, 10 KA, \"B\" curve. Make: Indoasian, Havells, Standard, Schnieder. | | 110 | Each |
|---|
| 61 | 61 | S&F in replacement MCB SP 40-63 Amps 240 Volt, 10 KA, \"B\" curve. Make: Indoasian, Havells, Standard, Schnieder. | | 5 | Each |
|---|
| 62 | 62 | S&F in replacement MCB SPN 40-63 Amps 240 V,10 KA, \"B\" curve. Make: Indoasian, Havells, Standard, Schnieder. | | 10 | Each |
|---|
| 63 | 63 | S&F in replacement MCB TP 40Amps 415 Volt, 10 KA, \"C\" curve. Make: Indoasian Cat No. 811196 or equivelent in Havells, Standard, Schnieder. | | 2 | Each |
|---|
| 64 | 64 | S&F in replacement LED lamp (Bulb) 7 watt. Make: Luker Cat No. LBPC07CL, C&S Cat No. LTHPLEDLAMP7WB22 BULB or equivelent Philips, Crompton, Havells. | | 50 | Each |
|---|
| 65 | 65 | S&F in replacement LED lamp (Bulb) 12 watt. Make: Luker Cat No. LBPC12CL, C&S Cat No. LTHPLEDLAMP12WB22 BULB or equivelent in Philips, Crompton, Havells. | | 50 | Each |
|---|
| 66 | 66 | S&F LED tube rod T8 , 20 watt polycarbonate suitable for 4 ft tube light fittings complete all as specified and directed at site. Make: C&S Cat No. LT4F20WLEDT8/WD or lucker no.LT1818T or equivelent in Havells, Crompton, Philips. | | 150 | Each |
|---|
| 67 | 67 | S&F LED tube rod T5 retrofit 18 watt TARIKA SERIES, polycarbonate LED T5 retrofit tube complete all as specified and directed at site. Make: C & S Cat No. LT4F18WLEDT5/WD, or equivelent in Havells, Crompton, Philips.Luker | | 25 | Each |
|---|
| 68 | 68 | S&F flexible PVC conduit 25 mm dia in repair complete all as specified and directed at site.\nMake: Avon Plast/Presto plast /Modi | | 25 | RM |
|---|
| 69 | 69 | Dismantling and taking down the defective geysers 25 Ltrs capacity from wall after disconnecting inlet and outlet water connection and un-screwing bolts and nuts carefully for repairs. \nNote: Repair works will be measured and paid seperately under relevant items. | | 20 | Job |
|---|
| 70 | 70 | All as per item No 69 but for the geyser of 50 Ltrs capacity | | 10 | Job |
|---|
| 71 | 71 | M & L for refixing only geyser 25/50 Ltr capacity in position and connecting water line, electric connection, including replacement of rusted hold fasteners, nut, bolts if required etc after repair. \n Note: Repair works will be measured and paid seperately under relevant items. | | 25 | Each |
|---|
| 72 | 72 | Supply and fix in repairs apparatus assembly complete without heating element and thermostat suitable for geysers of any make and capaity 25/50 Ltr. | | 4 | Each |
|---|
| 73 | 73 | Supply and fix in repairs heating elements 1500w in the existing geysers of any make or type. \n Make : Bajaj/Recold/VENUS. | | 15 | Each |
|---|
| 74 | 74 | Supply and fix in repairs heating elements 2000W in the existing geysers of any make or type.\nMake : Bajaj/Recold/VENUS. | | 8 | Each |
|---|
| 75 | 75 | Supply and fix in repairs thermal cut out of bimetallic disc type with snap action switch with manual reset knob for geyser of any make and of capacity 25/50 Ltr. | | 3 | Each |
|---|
| 76 | 76 | Supply and fix in repairs themostat suitable for geysers 25/50 Ltr capacity of any make existing with temperature range between 25 degree centrigrade to 75 degree centrigrade. | | 10 | Each |
|---|
| 77 | 77 | Supply and fix in repairs bottom plate for geyser 25/50 Ltr capacity of any make after disconnecting inlet and outlet connection. | | 3 | Each |
|---|
| 78 | 78 | Supply and fix in repairs indicator lamp Red/green 230 Volt suitable for water heater (Geyser).\nMake: AE/MECCO | | 10 | Each |
|---|
| 79 | 79 | Supply and fix in repairs PVC connecting pipe 450 / 600 mm long, suitable for hot & cold water, both ends socketed suitable for GI pipes 15mm bore. \nMake:prayag/watertech/Pyarryware/Jaguar. | | 20 | Each |
|---|
| 80 | 80 | Taking down the geyser of capacity 25 Ltr carefully, scrubing of the old defected painted surface and M&L for apply one coat of primer and then painting with one coat of synthetic enamel paint, rewriting the MES number and refixing the geyser in the same position after necessary drying up process all as specified and directed. | | 3 | Job |
|---|
| 81 | 81 | All as per item No 80 but the geyser of capacity 50 ltrs | | 3 | Job |
|---|
| 82 | 82 | M & L in repairs for galvanised steel tubing 15mm dia medium grade (ISI marked) including fitting and fixing arrangements on wall/ceiling.\nMake:TATA/ZENITH/JINDAL(ISI Marked) | | 25 | RM |
|---|
| 83 | 83 | Supply and fix in repairs stop valve cast copper alloy, high pressure with crutch or butterfly handle, 15 mm dia both ends screwed suitable for GI pipe conforming to IS-778-CI-15 all as specified and directed.\nMake:ZOLOTO/HM/SEIKO/GEM/LEADER/SANT | | 4 | Each |
|---|
| 84 | 84 | Supply and fix in repairs gun metal gate valve heavy duty ISI marked with iron wheel head screwed both ends for iron pipes 20 mm size \nMake:ZOLOTO/HM/SEIKO/GEM/LEADER/SANT | | 3 | Each |
|---|
| 85 | 85 | All as per item No. 84 above but 25 mm size. | | 1 | Each |
|---|
| 86 | 86 | Supply and replacement of plug top 15 amps three pin. \nMake: Anchor, Cona,SSK. | | 5 | Each |
|---|
| 87 | 87 | Supply and fix in repairs PVC flexible cable three core with copper conductor of size 2.5 sqmm for geyser connection.\nMake:'V' Guard /Havells/Asian/Polycab | | 50 | RM |
|---|
| 88 | 88 | Supply and fix in repairs pressure reducing valve (Air release valve)brass both ends screwed suitable for galvanised steel tubes 15mm dia.\nMake:ZOLOTO/HM/SEIKO/GEM/LEADER/SANT/VENUS | | 2 | Each |
|---|
| 89 | 89 | M & L in repairs for galvanised steel tubing medium grade 20mm bore including fitting and insulation all around with 50mm thick section of bonded mineral wool/glass wool covered with aluminium sheet for hot water line including all fixing arrangement and connecting to the existing line. \nMake:TATA/ZENITH/JINDAL (All ISI Marked) | | 10 | RM |
|---|
| 90 | 90 | All as per item No. 89 but for 25mm bore. | | 10 | RM |
|---|
| 91 | 91 | M & L for detecting leakage and arresting water leakage by brazing/soldering for any capacity of geysers and inserting the inner tube in to position including replacement of gasket, bolt and nuts etc complete. | | 5 | Job |
|---|
| 92 | 92 | Supply and fix in repairs by grouting anchor bolt suitable for bearing 200 KG capacity weight on wall for installation of geyser all as directed by Engineer-in-Charge. | | 6 | Each Bolt |
|---|
| 93 | 93 | Supply and fix in repairs MCB DB SPN 240 volts, 2 way sheet metal enclosure with 01 No MCB SPN, 240volt, 10-20 Amps. | | 2 | Each |
|---|
| 94 | 94 | Supply and replacement heating elements 2KW capacity with inbuilt thermostat suitable for 100 liters capacity solar water heater. \nMake:TATA BP/KONARK/RASMI | | 9 | Each |
|---|
| 95 | 95 | All as per item No. 94 but for capacity 3KW & 200 liters capacity. \nMake:TATA BP/KONARK/RASMI | | 7 | Each |
|---|
| 96 | 96 | Supply and fix in replacement sacrificial anode of capacity as per existing size suitable for solar water heater.\n Make:TATA BP/KONARK/RASMI. | | 5 | Each |
|---|
| 97 | 97 | Dismantling and taking out the unserviceable copper tube de-assembling from the solar panel, cleaning the system with suitable chemicals detecting and arresting the water leakage/blockage by cutting and soldering and reinstaling the cutting and soldering the copper tubing assembly water inlet and outlet to the system and testing complete all as directed. | | 8 | Job |
|---|
| 98 | 98 | M & L for servicing solar water heater system complete after drain out water from inner storage tank of capaicty 100 liters /200 liters , flushing out the system, including replacement of coupling washer, flushing out the solar panel copper tubing with chemicals for removing the scale detecting water leakage if any complete all as specified and directed. | | 16 | Job |
|---|
| 99 | 99 | Dismantling and taking out the inner tank of capaicty 100 liters /200 liters of solar water heater, after disconnecting water and electric connections, shifting the same to local work shop and arresting water leakage by brazing/soldering and inserting the same in to its original position and connecting and testing complete. | | 7 | Job |
|---|
| 100 | 100 | M & L for non return valve (Brass) size 20 mm dia including taking out unserviceable old valve complete. \nMake : Leader/Zoloto/sant | | 5 | Each |
|---|
| 101 | 101 | All as per item No. 100 but for 25mm dia | | 1 | Each |
|---|
| 102 | 102 | Supply & fix in repairs 40/32 mm rubber hose for solar water heater with 02 Nos clip for the hose. | | 18 | Each |
|---|
| 103 | 103 | Supply and replacement Solar water heater tank of capcaity 100 Ltr including connecting up water pipes and electrical connections all as specified and directed. \nMake: TATA BP/KONARK/RASMI | | 1 | Each |
|---|
| 104 | 104 | Supply and fix 7 Fin Toughened glass suitable for 100 liters capaicty solar water heater of make TATA BP /Rashmi /Konark including taking down the old unservicable glass and dispose the same as directed. | | 1 | Each |
|---|
| 105 | 105 | All as per item No. 104 but of 9 Fin Toughened glass . | | 1 | Each |
|---|
| 106 | 106 | All as per item No. 104 but of 11 Fin Toughened glass suitable for 200 liters capaicty solar water heater of make TATA BP /Rashmi /Konark . | | 1 | Each |
|---|
| 107 | 107 | All as per item No. 104 but of 12 Fin Toughened glass suitable for 200 liters capaicty solar water heater of make TATA BP /Rashmi /Konark . | | 1 | Each |
|---|
| 108 | 108 | Supply and fix in replacement copper fins of 100/200 liters capacity solar water heater all as specified and directed. | | 2 | Each |
|---|
| 109 | 109 | Supply and replacement Solar water heater tank of capcaity 200 Ltr including connecting up water pipes and electrical connections all as specified and directed. \nMake: TATA BP/KONARK/RASMI | | 1 | Each |
|---|
| 110 | 110 | Taking down ceiling fan of any size, type and make after disconnecting the electrical connections, servicing, cleaning, greasing, replacing the, rubber bush ,lock pin and re-assembling/hanging the same back at site complete all as directed by Engr-in-charge.\nNote:- i)Spares such as bearing/bushes shall be measured and paid seperately under relevant item. \nii) Any other minimum spare which is not included in BOQ (schedule) but needs replacement shell be born by tenderer without any extra cost. | | 400 | Each |
|---|
| 111 | 111 | M & L for replacing the old unserviceable bearings of sizes suitable for 1200/1400 mm sweep ceiling fan. | | 126 | Each |
|---|
| 112 | 112 | M & L for replacing the old gun metal bushes of sizes suitable for 1200/1400 mm ceiling fan. | | 60 | Each |
|---|
| 113 | 113 | Removing the ceiling fan from position after dismantling the electrilcal connectioin and taking down the old burnt out copper winding wire and rewinding the same by using same gauge of copper wire duly applying varnish and insulation material complete all as directed for 1200/1400 sweep ceiling fan. | | 150 | Each |
|---|
| 114 | 114 | Removing the exhaust fan from position of any size type and make, after disconnecting the electrical connections, servicing, cleaning, greasing, and re-assembling/fixing the same in position back at site complete all as directed by Engr-in-charge.\nNote:- i) Spares such as bearing/bushes shall be measured and paid seperately under relevant item. \nii) Any other minimum spare which is not included in BOQ (schedule) but needs replacement shell be born by tenderer without any extra cost. | | 50 | Each |
|---|
| 115 | 115 | M & L for replacing the old unserviceable bearings of sizes suitable for exhaust fan of size 280 mm sweep to 450 mm sweep. Make: SKF, NBC,TATA. | | 25 | Each |
|---|
| 116 | 116 | M & L for replacing the old gun metal bushes of sizes suitable for exhaust fan of any size after dismantling the electrilcal connectioin. | | 20 | Each |
|---|
| 117 | 117 | Removing the exhaust fan from position and taking down the old burnt copper winding wire and rewinding the same by using same gauge of copper wire duly applying varnish complete all as directed of size 300/305 mm. | | 25 | Each |
|---|
| 118 | 118 | All as per item No 117 but of size 380 mm. | | 5 | Each |
|---|
| 119 | 119 | All as per item No 117 but of size 450 mm. | | 5 | Each |
|---|
| 120 | 120 | Removing the wall mounted fan/air circulator/ pedestal fan of any size, type and make after disconnecting the electrical connections, servicing, cleaning, greasing reassembling/ hanging the same in position back at site complete all as directed by Engineer-in-charge.\nNote:- i) Spares such as bearing/bushes shall be measured and paid seperately under relevant item. \nii) Any other minimum spare which is not included in BOQ (schedule) but needs replacement shell be born by tenderer without any extra cost. | | 15 | Each |
|---|
| 121 | 121 | M & L for replacing the old unserviceable bearings of sizes suitable for wall mounted fan/ air circulator/ pedestal fan of any size. Make: SKF, NBC,TATA. | | 7 | Each |
|---|
| 122 | 122 | M & L for replacing the old unserviceable gun metal bushes of sizes suitable for wall mounted fan/air circulator/ pedestal fan of any size. | | 5 | Each |
|---|
| 123 | 123 | Taking down old burnt out copper winding wire of wall mounted fan/air circulator/ pedestal fan of size 300 mm and rewinding the same by using same gauge of copper wire duly applying varnish complete all as directed by Engineer-in-Charge. | | 10 | Each |
|---|
| 124 | 124 | All as per item No 123 but of size 450 mm. | | 5 | Each |
|---|
| 125 | 125 | M&L for replacing unserviceable capacitors from Ceiling fan/Exhaust fan/wall mounting fan/air circulator of any sizes complete of capacity 2.5 MFD. EPCOS, Havells, Keltron, Crompton. | | 200 | Each |
|---|
| 126 | 126 | All as per item No. 125 above but of capacity 4 MFD. Make: EPCOS, Havells, Keltron, Crompton. | | 30 | Each |
|---|
| 127 | 127 | M & L for replacement of unserviceable burnt flexible wire copper conductor twisted 2 core 16/0.20 mm size and connecting to ceiling fan all as directed. | | 100 | RM |
|---|