Road Transport and Highways Private Organizations Closing in 0 days TDR #24289744

Modification To Metering Panel Board For Individual Kseb Power Connectionto Various Kiosks In Vyttila Mobility Hub Bus Terminal Electrical Panel Room Modification

Issued by Private Organizations · vyttila mobility hub bus terminal, Kerala
Tender Value
4.59 Lakhs
Estimated cost
Bid Submission
20 May 2020
0 days left
EMD
11500
Bank guarantee accepted
Document Fee
1100
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
vyttila mobility hub bus terminal → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Modification To Metering Panel Board For Individual Kseb Power Connectionto Various Kiosks In Vyttila Mobility Hub Bus Terminal Electrical Panel Room Modification

BOQ

Name of Work: Modification of Metering Panel Noard for individual KSEB Power connection to Various Kiosks in Vyttila Mobility Hub Bus Terminal
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
10Laying and Jointing PVC Pipe. HeadingBI01010001010000000000000515BI0100001112
21Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5core 185 sq mm with factory made clampBI01010001010000000000000515BI010000111325mts
323.5core 120 sq mm with factory made clampBI01010001010000000000000515BI010000111410mts
433.5core 70 sq mm with factory made clampBI01010001010000000000000515BI010000111510mts
54Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ GI/ DWC pipe as required.3.5 core 185 sq mmBI01010001010000000000000515BI0100001116115mts
65Supply and making outdoor end termination for 1.1 KV grade PVC/PILC/XLPE cables of the following sizes including supply of end sealing kit consisting of cable jointing compound, hardener, plastic mould, adhesive-cum-solvent, epoxy putty, earth continuity connection, spacers and PVC (NA) tape. for 3.5 C 185sq.mm cableBI01010001010000000000000515BI01000011172nos
76Supply & laying of DWC pipe in hard soil 0.75m below ground level including excavation175 / 147 mm or nearest sizeBI01010001010000000000000515BI0100001118115mts
87Supplying siemens / tropodur type nickel plated single compression brass cable gland for PVC insulated and PVC sheathed armoured aluminium/ copper conductor cable 1.1 KV grade, and making end termination suitable for 3½ core 185 sq mmBI01010001010000000000000515BI01000011192nos
983½ core 120sq mmBI01010001010000000000000515BI01000011202nos
1093½ core 70 sq mmBI01010001010000000000000515BI01000011212nos
1110Supplying and providing earth clamps for siemens/ tropodur type cable glands of suitable length and other dimensions noted along with each size of glands for the following sizes of cables as required.20 x 3 mm for earthing glands of size 120 sq mm to 185 sq mmBI01010001010000000000000515BI01000011224nos
12113½ core cable 70 sq mmBI01010001010000000000000515BI01000011232nos
1312Supply of superior quality aluminium tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.185sq mmBI01010001010000000000000515BI010000112412nos
141395 sq mmBI01010001010000000000000515BI01000011254nos
1514120 sq mmBI01010001010000000000000515BI01000011266nos
161570 sq mmBI01010001010000000000000515BI01000011278nos
171635sq mmBI01010001010000000000000515BI01000011282nos
1817Laying and clamping charges of existing of 1 no. PVC insulated and PVC sheathed armoured power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.up to 25 sq,mm or nearest sizeBI01010001010000000000000515BI010000112960mtr
1918Supplying and installation including all manner of supports/ suspenders, anchor bolts etc for cable trays made out of suitable size channel sections, slotted angles, flats, MS plates etc as required including painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.BI01010001010000000000000515BI0100001130150kg
2019Fabrication, supply, conveyance and fixing frame work made out of suitable size angle iron/ flat cut and welded to shape of suitable size painted with 2 coats of synthetic enamel paint over a coat of red oxide primer & with drilled holes to mount the switch gear, fixed to wall using suitable size anchor bolts or grouted to wall, making good the damages, colour washing etc as requiredBI01010001010000000000000515BI010000113115kg
2120Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using 1.60 mm CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments should be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc. including control wiringBI01010001010000000000000515BI010000113216M2
2221- Do using 2.00 mm CRCA sheet for Out door type enclosureBI01010001010000000000000515BI01000011332m3
2322Supply and fixing the following types of beeding along the periphery of doors/ other detachable compartments to make the panel assembly dust & vermin proof including sticking with glue. 'A' section neoprene beeding suitable for 1.60/ 2.00 mm sheetBI01010001010000000000000515BI010000113440mtr
2423Supply and providing the following size of SMC sheets in the panel as barriers & shrouding using required bolts and nuts including cutting to shape etc., as required.3 mm thickBI01010001010000000000000515BI01000011351m2
2524Fabrication, supply, conveyance and installation of base frame for floor mounting type panel board using channel of class designation ISMC 75 including cutting, welding, drilling holes, painting with two coats of synthetic enamel paint over a coat of zinc chromate primer, bolting the frame to the panel and to the finished floor using required bolt and nuts, making good the damages etc. as required.BI01010001010000000000000515BI01000011365mtr
2625Fabrication, supply, conveyance and installation of angle iron frame work for wall mounting panel board using suitable size angle iron cut and welded to shape including painting with two coats of synthetic enamel paint over a coat of zinc chromate primer, bolting the frame to the panel using required bolt and nuts, fixing the whole to the wall, making good the damages etc. as required.BI01010001010000000000000515BI010000113715kg
2726Fabrication, supply & fixing main bus bar system and interconnections with electrolytic grade copper strips/ rigid conductors conforming to IS 1867 (with latest amendments) for bus bar arrangement with single strip per phase supported on finger type bus bar supports of adequate size, spacing between supports not exceeding 50 cm & overhang not exceeding 5 cm including bending to shape, drilling holes, tinning the points of contacts, fixing heat shrinkable PVC sleeves, plated bolts and nuts with plate washers and spring washers, copper sockets for round conductors, etc., as required.BI01010001010000000000000515BI01000011381500cm3
2827Fabrication, supply & fixing earth bus system with copper strip/ conductor and connecting all accessories as per rule including g tinning the points of contacts etc as requiredBI01010001010000000000000515BI0100001139700cm3
2928250 A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SCBI01010001010000000000000515BI01000011401No
3029125 A, TP/TPN AC 23 A dutyBI01010001010000000000000515BI01000011412nos
313063A, AC 23 A, TPN SDF for DIN fuseBI01010001010000000000000515BI01000011424nos
3231100A DIN type fuse link of size 00BI01010001010000000000000515BI01000011436nos
33322 -80A, DIN type fuse link of size 000BI01010001010000000000000515BI010000114424nos
343363 A, 415 V Backelite fuse fittingBI01010001010000000000000515BI010000114512nos
353463 A, 415 V, 2 way neutral link mounted on DMC/ SMC base.BI01010001010000000000000515BI01000011464nos
3635250 A, 415 V, DIN type fuse base.BI01010001010000000000000515BI01000011473nos
3736120A DIN type fuse link of size 00BI01010001010000000000000515BI01000011483nos
3837100/ 5 A, 5 VA, resin cast metering CT of accuracy class 0.5BI01010001010000000000000515BI01000011493nos
393850/ 5 A, 5 VA, resin cast metering CT of accuracy class 0.6BI01010001010000000000000515BI01000011503nos
40393 phase, 4 wire, 220 V ( L-N), suitable for -/1 A CT or -/5A CT with RS 485 port of class 0.5. TOD Enegymeter L&T make model ER300 P class 0.50 Cat. No: WR300BC 12 RsBI01010001010000000000000515BI01000011511nos
41403 phase, 4 wire, 220 V ( L-N), suitable for 10- 60A class 1 Enegymeter L&T make model ER300 P class 0.50 Cat. No: WR300BC 73BOXHBI01010001010000000000000515BI01000011521nos
4241Aluminium anodised Danger Notice Board of size 200 x 150 mm. with inscriptions ( both in English and Malayalam) and conventional Skull and Bone in Red colour.BI01010001010000000000000515BI01000011532nos
4342Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.6.00 sq mm single run with required sockets.BI01010001010000000000000515BI010000115416mtr
444370.00 sq mm single run with required sockets.BI01010001010000000000000515BI01000011558mtr
4544Supply and providing plate earthing as per IS 3043 with 600x600x6.3 mm GI/CI earth plate, 20 mm GI watering pipe fixed to the earth plate with 20 x 3 mm GI clamps, GI funnel with weld mesh, filling required quantity of charcoal including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40 mm broken stone (10 cm thick), brick work in cement mortar 1:6, plastering the surface of brick masonry and the exposed surface of PCC bed with cement mortar 1:4, 12 mm thick, (the finished inside dimension shall be 300 x 300 x 300 mm) but excluding test joint, earth continuity conductor to the plate, and covering at the top. (in ordinary soil)BI01010001010000000000000515BI01000011562nos
4645Supply and providing the following sizes of cast iron gully trap with covering at the top of the inspection chamber of earth pit as required 300 x 300 x 6 mm cast iron gully trap with coveringBI01010001010000000000000515BI01000011572nos
4746Supply and providing test joint for the earthing system using 2 Nos of the following sizes of strips including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required.2x32x6 mm GI stripBI01010001010000000000000515BI01000011580.5mtr
4847Supply and providing earth lead from the test joint to the earth electrode using the following sizes of conductors/ strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required.32 x 6 mm GI strip mm GI stripBI01010001010000000000000515BI01000011598mtr
4948Supply and laying the following sizes of bare copper laid 0.60 m below ground level including excavating trench of suitable size and refilling etc. as required (in ordinary soil)4.0 mm copper conductor (8 SWG)BI01010001010000000000000515BI010000116020mtr
5049Supply and laying the following sizes of strips laid 0.60 m below ground level including excavating trench of suitable size and refilling etc. as required (in ordinary soil).32 x 6 mm GI stripBI01010001010000000000000515BI010000116126mtr
5150Supply and clamping the following sizes of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 x 3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1m, making good the damages, colour washing etc. as required .32 x 6 mm GI stripBI01010001010000000000000515BI010000116230mtr
5251Supply and providing the following sizes of bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required25 x 8 mm GI bolt & nutBI01010001010000000000000515BI010000116316nos
5352Painting letters or figures of the following sizes with enamel paint as identification mark to SB, DB, panel board etc as required 2.50 cm, 4 cm or 5 cm heightBI01010001010000000000000515BI0100001164250nos
5453Supply and providing 2mm thick Elastomeric fire retardent insulating mat as per IS 15652/2006 to withstand 3.3 KV dielectric strength.BI01010001010000000000000515BI01000011654m2
5554Supply and providing 5 Kg. Dry Chemical Powder type Fire Extinguisher with hose and clamps including fixing it to wall as required.BI01010001010000000000000515BI01000011662nos
5655Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision.BI01010001010000000000000515BI01000011671nos
5756Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint 'FIRE' mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand including making good the damages, colour washing etc. as required.BI01010001010000000000000515BI01000011684nos
5857Charges for tesing fee for testing Energymeter at TMR Division Angamally actual amount paid on production of orginal invoice or challanBI01010001010000000000000515BI01000011691LS

AI Tender Summary

OUR REF NO 24289744
AUTHORITY Private Organizations
TENDER VALUE 4.59 Lakhs
LAST DATE 20-05-2020
Authority
Authority Name Vyttila Mobility Hub Society
Work Description Modification To Metering Panel Board For Individual Kseb Power Connectionto Various Kiosks In Vyttila Mobility Hub Bus Terminal Electrical Panel Room Modification
Basic Detail
Tender No 05/VMHS/2019-2020
Bidding Type Tender
Location
City vyttila mobility hub bus terminal
State Kerala
Key Dates
Publish Date 11 May 2020
Submission Date 20 May 2020
Open Date 22 May 2020
Finance
Tender Value 4.59 Lakhs
Tender Fee 1100
EMD 11500
Exemption Not Available
Document List
Tendernotice_1.pdf
Retendernit-converted.pdf
declaration.pdf
Preliminaryagreement.pdf
BOQ_499744.xls
EPAY.pdf
459BB9F9-5F92-4F2D-8C86-4DE9B2D5F4AD.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

May 11, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
May 20, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
May 22, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

pdf

Retendernit-converted.pdf

pdf

declaration.pdf

pdf

Preliminaryagreement.pdf

xls

BOQ_499744.xls

pdf

EPAY.pdf

html

459BB9F9-5F92-4F2D-8C86-4DE9B2D5F4AD.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders