Improvement And Up Gradation Of Drinking Water Supply Scheme To Solan Town From Giri River Sub Head _ Provision For Replacement Of Old Rising Main 450Mm Dia At Rd 0 To 70 And Rd 110 To 1835 And Pumping Machineries In Tehsil And District Solan Hp, Solan-Himachal Pradesh

Irrigation And Public Health Department has published Improvement And Up Gradation Of Drinking Water Supply Scheme To Solan Town From Giri River Sub Head _ Provision For Replacement Of Old Rising Main 450Mm Dia At Rd 0 To 70 And Rd 110 To 1835 And Pumping Machineries In Tehsil And District Solan Hp. Submission Date for this Tender is 20-05-2020. Water Supply Project Tenders in Solan Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

24263512
Improvement And Up Gradation Of Drinking Water Supply Scheme To Solan Town From Giri River Sub Head _ Provision For Replacement Of Old Rising Main 450Mm Dia At Rd 0 To 70 And Rd 110 To 1835 And Pumping Machineries In Tehsil And District Solan Hp
Open Tender
Indian
Himachal Pradesh
Solan
20-05-2020

Tender Details

Improvement And Up Gradation Of Drinking Water Supply Scheme To Solan Town From Giri River Sub Head _ Provision For Replacement Of Old Rising Main 450Mm Dia At Rd 0 To 70 And Rd 110 To 1835 And Pumping Machineries In Tehsil And District Solan Hp

Key Value

Document Fees
INR 2500 /-
EMD
INR 645413.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Improvement & Up-gradation of Drinking water Supply Scheme to Solan Town from Giri River (SH:- Provision for replacement of Old Rising Main 450mm dia at RD 0 to 70 & RD 110 to 1835 & Pumping Machineries in Tehsil & Distt. Solan (HP).
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Dismantling of old existing flanged API Pipes 450 mm dia stacking of pipes at site lead upto (500m) all lead and lifts and as per direction of Engineer in-Charge.
2 1.01 From RD 0 to 70 140 Rmt
3 2 Excavation in foundation and trenches up to all depths and in all classification of earth work such as pick work, jumper work, situated soil including bailing or pumping out water, blasting soft/ hard rock, chiseling /wedging of soft / hard rock where blasting is prohibited, in all lifts including trimming and dressing of sides, leveling of beds to correct grade including shoring, strutting, planking, timbering and dewatering wherever required. Stacking usable and unusable material /soil separately and after laying jointing and testing of pipes, returning the usable soil in 15cm layers by ramming and watering and then disposing of all surplus excavated soil/ unusable material as directed with in all leads/ lifts including restoration of un-metalled surfaces to its original conditions and including cost of diversion for traffic, night signal boards, fixing caution boards, crossing over trenches for access to houses, fencing etc. Complete in all respects within all leads and lifts as per direction of the Engineer-in-Charge. 971.3 Cum
4 3 Providing and laying cement concrete 1:4:8 (1cement: 4 sand: 8 graded crushed stone aggregate 40mm nominal size )and curing complete excluding cost of form work in foundation and plinth with in all leads & lifts as per the entire satisfaction & direction of Engineer - in - charge. 10.04 Cum
5 4 Providing and laying in CC 1:2:4 (1cement 2 sand 4 graded stone agg.20mm nominal size) and curing complete excluding cost of centering & shuttering in foundation and plinth within all leads and lifts. 69.36 Cum
6 5 Providing form work with steel plates 3.15mm thick welded with angle iron in frames 30x30x5mm so as to give a fair finish including centering ,shuttering, propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 meters and removal of the same for-in-situ reinforced concrete and plain concrete work in all leads and fifts in:-
7 5.01 Column and Pillars, posts etc. complete in all respect. 1680 Sqm
8 6 Providing & laying cement concrete 1:1.5:3 (1 cement : 1.5 Sand 3 graded stone aggregate 20 mm nominal concrete) and curing complete excluding cost of form work and RCC Work in a) Column pillars, posts and struts upto floor two level complete in all respect. 524.16 Cum
9 7 Providing tor steel reinforcement for RCC work including bending,winding and placing in position as per the direction of Engineer-in-charge including entire carriage of material upto all leads and lifts complete in all respect. 20996 Kg
10 8 Providing , laying, jointing testing& commissioning in trenches API pipes confirming to API 5L standard and of grade X- 70 having wall thickness as specified below with plain end and capable of withstanding required test pressure in random length of 4 to 7 meters, including specials, short pieces, bends, reducers, tees etc. made from parent tube, provinding and welding of MS flanges detailed as below. The MS flanges shall confirm to BIS 6392-1971 (with latest up to date amendments) duly welded in two layers (two inner and two outer) with pipes at both ends as per relevant BIS standards along with nuts and bolts of required sizes, 3mm thick compressed asbestos fiber/synthetic rubber gaskets confirming to relevant BIS standards. The laying of pipe will include all operation such as cutting, welding, jointing, providing & fixing of MS flanges, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards and the damaged portion of the pipes and specials made form the parent tube shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately).
11 8.01 450 mm dia Zinc coated pipes of 14.30 mm wall thickness for twin R/Main RD 0 to70 (2x70) 140 Rmt
12 8.02 450 mm dia Zinc coated pipes of 10.30 mm wall thickness for twin R/Main RD 1110 to 1835 (2x725) 1450 Rmt
13 9 Providing welding and fixing flanges of 450 mm dia (nominal bore) of class ASA-900 Conforming to ASA Standard(B-16.5) latest with upto date amendments to API pipe after every fifth pipe or as per site requirement including cutting of pipes wherever required welding in three layers (leak proof) conforming to specifications as prescribed in relevent IS code i.e IS 816-1969 or latest as applicable with upto date amendments with nuts, bolts & washers and specials etc. fonforming to IS 1963 or latest with upto date amendments including packing sheet i.e. metallic gasket of superior make/quality) of minimum 3mm thick and painting with anticrossive paints complete in all respect in all leads lifts and carriage of material at site and as directed by the Engineer-in-charge. 55 Pair
14 10 P/F at site of Kirloskar /Leader/ KSB/ Fouress make flanged cast steel non return Valve of 450 mm dia of Class ASA 900 capable of withstanding nominal seat pressure 110 kg/cm2 confirming to ASA Standard with upto date amendments complete with mating flange, nut bolts gaket etc. in all leads and lifts and to the entire satisfaction of Engineeer-in Charge.(for twin R/Mains 450 mm dia 2 Each
15 11 P/F at site of KSB/Leader/Kirloskar/Fouress make Cast steel scour valveof 200 mm dia Class ASA 900 capable of withstanding nominal seat pressure 110 kg/cm2 confirming to ASA Standard with upto date amendment complete with mating flange, nut bolts gasket etcin all leads and lifts upto the satisfaction of Engineer in-Charge. (for scouring of twin rising main) 2 Each
16 12 Providing, laying, jointing testing and commissioning of galvanised bevelled ended MSERW pipe conforming to IS/ISO 3183-2007 and of Grade-A or L-210 latest with upto date amendments at site in trenches of 200mm dia of 4.8 mm thickness & per rmt Weight as mentioned below & capable of withstanding required test pressure as prescribed in BIS Code, in random length 5.5 to 6.5 mtrs. The Pipes shall be bevelled suitable for butt welding i/c cost of jointing with butt welding confirming to BIS 816-1969 or latest as aplicable ends with upto date amendments (leak proof) in three layers at site of work with welding rods of standard make and all allied accessories whatever required for welding at site, tail peices, tees bends & other special manufacturer from parent pipes as applicable to the particular reach & of approved specification as per site conditiones and cutting of pipes whereever required as per site requirement i/c carriage in all leads and lifts and as per direction of Engineer in Charge. The pipe shall have a zinc coated inside and outside confirming to IS 4736-1986 or latest with upto date amendments & shall be engraved with yst -210 code IS-1978 or its equivalent. The laying shall confirm to BIS 5822-1970 or latest with upto date amendments to the entire satisfaction of Engineer in Charge.(Earth work shall be measured and paid for seperately). 580 Rmt
17 12.01 From (RD) To (RD) Length of R/Main Dia of pipe Per Rmt Weight wall thickness
18 12.02 P/Well 1 to balancing reservoir 0 460 460 200 25.37 Kg 4.8
19 12.03 P/Well 1 to balancing reservoir 0 120 120 200 25.37 Kg 4.8
20 12.04 Total = 580 Rmt.
21 13 Providing, laying jointing testing and commissioning of galvanised bevelled ended MSERW pipe conforming to IS/ISO 3183-2007 of Grade-A L-210 latest with upto date amendments at site in trenches 250mm dia 4.8 mm thick having wall thickness & per rmt Weight as mentioned below & capable of withstanding required test pressure as prescribed in BIS Code, in random length 5.5 to 6.5 mtrs. The Pipes shall be bevelled suitable for butt welding i/c cost of jointing with butt welding confirming to BIS 816-1969 or latest as aplicable ends with upto date amendments (leak proof)in three layers at site of work with welding rods of standard make and all allied accessories whatever required for welding at site, tail peices, tees bends & other special manufacturer from parent pipes as applicable to the particular reach & of approved specification as per site conditiones and cutting of pipes whereever required as per site requirement i/c carriage in all leads and lifts and as per direction of Engineer in Charge. The pipe shall have a zinc coated inside and outside confirming to IS 4736-1986 or latest with upto date amendments & shall be engraved with API- L -210 IS-3183-2007 or its equivalent. The laying shall confirm to BIS 5822-1970 or latest with upto date amendments to the entire satisfaction of Engineer in Charge.(Earth work shall be measured and paid for seperately). There shall be one flanged joint after every 90 mtr & flange shall be of flange table-5 confirming to BIS 6392-1971 latest with upto amendmentsi/c cost of welding flanges with pipes with three layers of weld, gasket etc of superior quality & of minimum 3mm thickness complete in all respects. 1250 Rmt
22 13.01 Gravity lines from balancing reservoir to existing raw water tank =1250 Rmt, 200 mm dia,21.22 kg/Rmt having wall thickness 4.00 mmm
23 14 Providing welding and fixing M.S plate flanges confirming to BIS 6392-1971 (latest with up to date ammendment )200 mm nominal & flange table-17 welded at both ends of MSERWpipe with three layers of weld leak proof according to revelant BIS code 816-1962 and provided with nuts and bolts of required size as per BIS code 1364 i/c 3mm thick compressed asbestor fibre gasket ofchampion make or other standard make confirming to revelant BIS code 2712-1965 complete in all respect i/c all leads and lifts. Flanges to be provided after 100 Rmt.
24 14.01 From To Length of R/Main No of flangeS F.T
25 14.02 P/Well No-1 Balancing reservoir 460 5 17
26 14.03 P/Well No-2 Balancing reservoir 120 2 17 7 Pair
27 15 P/F at site double flanged swing type cast iron reflux valve/ NRV of KSB/leader /BHEL/ kilosker /GLED/Fouress make of 200 mm dia having bye pass arrangement on the delivery line of the pump capable of with standing the normal seat pressure as per IS -5312-1984 (P-1) with upto date amendments Class PN 1.6 as direct by Engineer-in-Charge i/c carriage of material upto all lead and lifts.
28 15.01 For Percolation well no.1=2 nos
29 15.02 For Percolation well no.2=2 nos
30 15.03 Total = 4 Nos. 4 Each
31 16 P/F at site double flanged swing type cast steel Sluice valve of KSB/Leader /BHEL/ kilosker /GLED/Fouress make of 200 mm dia having bye pass arrangement on the delivery line of the pump capable of of with standing the normal seat pressure as per IS -780-1992 with upto date amendments Class PN 1.6 as direct by Engineer-in-Charge i/c carriage of material upto all lead and lifts. Class-300 4 Each
32 16.01 Pumping machinery for Percolation well pumping machinery no.1=2 nos
33 16.02 Pumping machinery for Percolation well pumping machinery no.2=2 nos
34 16.03 Total = 4 Nos.
35 17 P/F at site double flanged swing type cast steel Sluice valve of KSB/Leader /BHEL/ kilosker /GLED/Fouress make of 250 mm dia having bye pass arrangement on the gravity line capable of of with standing the normal seat pressure as per IS -780-1992 with upto date amendments Class PN 1.6 as direct by Engineer-in-Charge i/c carriage of material upto all lead and lifts. Class-300 1 Each
36 17.01 Gravity line for balncing reservoir No.1 = 1 No.)
37 17.02 Raw water stage-1(Percolation Well No.1)
38 18 Supply, erection, testing & commissioning of submersible pumping set of reputed make such as KSB/BS/Johnston/Worthington conforming to latest relevent BIS code. The pump should be fitted with free flow impellers of bronze /suitable alloy as per BIS 5659 or latest with up to date ammendments suitable for raw/clear water having greased packed bearings & shell with wound stator on motor side & with shaft protection sleeve on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to a submersible squirrel cage electric induction motor of Kirloskar/NGEF/Jyoti / Crompton make conforming to relevent BIS code with up to date ammendments totally dust & water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber chamber & grease packed lubricated bearings & provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor. The pump set should include water level guard, errection clamps, cable clips & depth gauge etc. & suitable for operation on data given below:-(2 Set of 40 HP) 2 Set
39 18.01 Tota Head:- 68.03
40 18.02 Capacity of each pump set:- 20.46 LPS
41 18.03 Dia of R/Main:- 200 mtr
42 18.04 Length of R/Main (In metres):- 460 mtr
43 18.05 SITE CONDITIONS & WATER CHARACTERSTICS :- TO BE FILLED BY EE WHILE CALLING TENDERS
44 18.06 Location of Site:- To be filled in by Engineer-Incharge before calling tenders
45 18.07 The altitude of place in which the motor is intended to work in ordinary service (in metres) :- To be filled in by Engineer-Incharge
46 18.08 Humidity:- Weather generally remains humid during monsoon season.
47 18.09 Nature of atmosphere:- As normally encounterd in Shivalik Range
48 18.1 Detail of quality of water:- To be filled in by Engineer-Incharge before calling tenders
49 18.11 Water free from sand or not :- To be filled in by Engineer-Incharge before calling tenders
50 18.12 Water corosive or not :- To be filled in by Engineer-Incharge before calling tenders
51 18.13 Turbidity (if any):- To be filled in by Engineer-Incharge before calling tenders
52 18.14 NPSH available:- To be filled in by Engineer-Incharge before calling tenders
53 18.15 Any other information or requirement:-
54 18.16 OPERATING CONDITIONS:- TO BE FILLED BY EE WHILE CALLING TENDERS
55 18.17 Type of current:- AC three/single phase
56 18.18 Operating frequency:- 50 HZ
57 18.19 Rated voltage:- 400 (+/-) 10% volts
58 18.2 System of earthing if any to to be adopted.:- Double loop earthing as per BIS 3043-1987 latest with upto date ammendments
59 18.21 No. of working hours per day:- 16 hours
60 18.22 Speed of revolution in RPM:- To be quoted by tenderer
61 18.23 Direction of rotation:- To be quoted by tenderer
62 18.24 The max. Temp. of cooling air & water in the place in which the motor is intented to work in ordinary service. To be filled in by Engineer-Incharge before calling tenders
63 18.25 MOTOR:-
64 18.26 Ref. to BIS code:- BIS 325-1978 read with BIS 900-1992 (latest)with upto date ammendments
65 18.27 Type of enclosure of motor:- SPDP (as per BIS 4691-1985 (latest)
66 18.28 Type of duty:- Continuous as per IS-12824-1989 or latest with up to date ammendments
67 18.29 Mechanical out put in KW:- Suitable for driving centrifugal pumps required for duties specified against pumps.To avoid overloading of motor a margin of about 15-20% may be kept in the rated out put of prime mover.
68 18.3 Class of insulation:- Class ~B~
69 18.31 Max.permissible temp.rise of motor reqd. if different from given in B(viii) above:- To be filled in by Engineer-Incharge before calling tenders
70 18.32 Particulars of test reqd. & where they are to be conducted:- As per terms & conditions
71 18.33 Particulars as to whether voltage limiting device will be employed:- ATS/ star delta starter,oil immersed,fully automatic to be installed between bus bar & motor Shunt capacitor is also proposed to be installed for improving the power factor at site.
72 18.34 (NOTE:- Star delta starter upto 37.5 KW, ATS between 37.5 KW to 50 KW & Stator rotor starter with slip ring motor beyond 50 KW)
73 18.35 Motor whether squirrel cage or slipring:- Squirrel cage/slip-ring
74 18.36 (Note:- Squirrel cage upto 65HP and slipring above 65HP)
75 18.37 Details of shaft extension reqd.:- Just sufficient to provide direct drive by flexible coupling to pump.
76 18.38 Type of slip-ring gear whether continouly rated or for starting purposes only & whether to be fitted with brush lifting or short circuit arrangements or both if interlocks are rquired.:- Continouslly rated for Squirrel cage/ Slipring motor
77 18.39 Breakway torque in terms of rated load torque & the corresponding breakway starting current which may be taken from the supply with the starting apparatus in circuit.:- Breakway torque to be given by the tenderer but the starting current should not exceed 2.5 times of the full load current.
78 18.4 Nature of load & any information regarding the driven machine which has a bearing upon the torque reqd. during the accelerated period, the kinetic energy of the moving parts to be accelrated & No.of starts during a specified period.:- Sufficient to work the pump offered
79 18.41 PUMP:- BIS 1520-1980 read with BIS 9137-1978 both with up to date ammendments
80 18.42 Nos of pumps reqd.:- 2 no. pumps, one will work at a time ,one stand bye
81 18.43 Spare parts required:- For two years normal maintenance as recommended by manufacturer.
82 18.44 Optional fittings reqd.:- Air cock for exahausting air from each stage.
83 18.45 PUMP OPERATING CONDITIONS:- TO BE FILLED BY EE WHILE CALLING TENDERS
84 18.46 Capacity of each pump set (in LPS):- 20.46
85 18.47 Total head (in Mts).:- 68.03
86 18.48 If total head is not known then
87 18.49 following details be provided:-
88 18.5 i) Static head ( in mtrs)
89 18.51 ii) Minimum depth of water( in mtrs)
90 18.52 iii) Variation in water level ( in mtrs)
91 18.53 iv) Ground level to max. water level ( in mtrs)
92 18.54 v) Ground level to delivery point ( in mtrs)
93 18.55 vi) Pressure in the suction tank (in Kg/cm^2 )
94 18.56 vii) Pressure in the delivery tank (in Kg/cm^2 )
95 18.57 Length of R/Main (in metres):- 460
96 18.58 Dia of R/Main (in mm):- 200
97 18.59 Drive arrangement:- Direct through flexible coupling on a common base plate
98 18.6 Drive type:- Electric driven
99 18.61 NPSH reqd.:- To be quoted by the tenderer
100 18.62 Limits of total head in which the pump is reqd. to operate.:- (-) 15% to (+) 10% of total head.
101 18.63 Suction/delivery size of pump:- To be specified by the tenderer
102 18.64 Efficiency of pump at:- To be specified by the tenderer
103 18.65 a) duty head (as mentioned at item No.18 (a) )=68.03 mts
104 18.66 b) (+)10 % of head as mentioned at item No.18 (a) =74.83 mts
105 18.67 c) (-) 15 % of head as mentioned at item No.18 (a) =57.82 mts
106 18.68 Material of construction:- To be specified by the tenderer (manufacturer~s certficate to be appended)
107 19 Supply & fixing at site of suitable direct on line/oil immersed star delta/ ATS/ stator rotor starter of standard make such as MEI/ Kilburn/ Jyoti/ Siemens/ Larson & Tubro conforming to BIS-8544-1979 latest with up to date ammendments for squirrel cage/ slip-ring motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot, time lag,under voltage release with initial oil filling . 2 Nos
108 19.01 Note:- Star - delta - starter upto 37.5 KW , ATS between 37.5 KW to 50 KW and stater rotor starter with slipring motor beyond 50 KW.
109 20 Providing & fixing at site M.S. sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting i/c the cost of providing and fixing in position the following accessories with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer in charge. 1 No.
110 20.01 Supplying & fixing at site Ammeter AC supply,100 mm dia circular dial Auto electric/ AE/ IMP/ Havells make of suitable range for above motor with selector switches conforming to BIS 1248-(P-II)1983 latest with up to date ammendments. 2 Nos
111 20.02 Supplying & fixing at site Voltmeter AC supply,100 mm dia circular dial Auto electric/AE/IMP/Havells make of suitable range for above motor with selector switches conforming to BIS 4064-1978 with up to date ammendments. 1 No.
112 20.03 Supplying & fixing at site ICTP switches with HRC fuses of Kilburn/Larsen & Tubro/Standard/Siemen/Havells make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediatly after the power meter of HPSEB. 2 Nos.
113 20.04 Supplying & fixing at site Busbar chamber having three copper bars of suitable rating for full length equal to width of board of three live phases and one copper bar of half rating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date ammendments. 1 No.
114 20.05 Supplying & fixing at site ACB/MCB/Oil circuit breaker of suitable capacity of Kilburn/L &T/MEI/GEC/Standard make on incomming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with initial oil filling whenever required & neutral linked under voltage release. 1 No.
115 20.06 Supplying & fixing at site Three phase indicating lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with up to date ammendments. 2 Set
116 20.07 Supplying & fixing at site earth leakage circuit breaker/relay of recommended make such as Kilburn/L&T/MET/GEC conforming to BIS-2516-1977 with upto date ammendments and of suitaible range which should have control box, oprating handel and trip/reset push button, on/ off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tap CTS. It should also be fitted earth fault for tripping of breaker on occurance of earth fault on/ of breaker load side. 1 No.
117 20.08 Supply & fixing Hour run meter of reputed make of four digit capacity conforming to BIS-722 (latest edition)/recommendations. 2 Nos
118 20.09 Supply & fixing Suitable three phase voltage monitor relay with all protections & usual indicators with electric sirens against single phasing, low voltage, high voltage & overloading & phase voltage difference as per IS-3842 with up to date ammendments. 1 No.
119 20.1 Change over switch of reputed make & suitable capacity. 1 No.
120 20.11 Supply & fixing Single phase preventor of reputed make & suitable capacity conforming to IS:1248 (P-V)-1983 with up to date ammendments 1 No.
121 21 Supply & fixing at site of Leader /Kirloskar/KSB/ Jyoti/ Standard/ Kilburn/Fouress/ Bir/ Kartar make cast iron flanged/ screwed type foot valve (In case suction lift is involved) for suction pipe having size one or two size larger than suction size of pump such that valocity of flow is not more than 2.50 mtr/sec. with strainer having net area of its openings equal to three to four times of x- sexctional area of flow in suction pipe conforming to BIS 4038-1986 or latest with up to date ammendments i/c all leads & lifts & as directed by Engineer -Inschage 2 Nos
122 22 Providing, laying, jointing & testing at site suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC make from meter of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost i/c cost of carriage of material in all leads & lifts & as directed by Engineer -Inchage.(2x15=30 mtr) 1 Job
123 23 P/L PVC jointless flat water proof cable as per BIS 694-1990 (latest with up to date ammendments) suitable for the pump sets offered from circuite breaker to motor & motor to starter including all other electrical equipments such as thimbles, flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost. (2x50=100 mtr) 1 Job
124 24 Providing & laying at site double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt, GI pipes, thimbles, nuts & bolts, digging of pits,GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments.i/c cost of carriage of material in all leads & lifts & as directed by Engineer -Inchage. 1 Job
125 25 Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer) i/c cost of carriage of material in all leads & lifts & as directed by Engineer -Inchage. 2 Nos
126 26 Supply & fixing at site of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 or latest with up to date ammendments. 2 Nos
127 27 P/F double flanged suction, delivery pipe & common header considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers,flanges, rubber gaskets 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of withstanding minimum 1.5 times the total pressure as indicated in item no. 1 (a) or total dynamic pressure + surge pressure whichever is more. The size of suction pipe shall be one or two sizes larger than the suction size of pump such that valocity of flow in suction pipe is not more than 2.50 mtr/sec & delivery pipe shall be of size one size larger than nominal delivery size of pump.i/c cost of carriage of material in all leads & lifts & as directed by Engineer -Inchage. 1 Job
128 27.01 NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge
129 28 Raw water stage-2/Percolation WELL No-2
130 28.01 Supply, erection, testing & commissioning of submersible pumping set of reputed make such as KSB/BS/Johnston/Worthington conforming to latest relevent BIS code. The pump should be fitted with free flow impellers of bronze /suitable alloy as per BIS 5659 or latest with up to date ammendments suitable for raw/clear water having greased packed bearings & shell with wound stator on motor side & with shaft protection sleeve on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to a submersible squirrel cage electric induction motor of Kirloskar/NGEF/Jyoti / Crompton make conforming to relevent BIS code with up to date ammendments totally dust & water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber chamber & grease packed lubricated bearings & provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor. The pump set should include water level guard, errection clamps, cable clips & depth gauge etc. & suitable for operation on data given below:-(2 Set of 20HP) 2 Set
131 28.02 Tota Head:- 36.61 mtr
132 28.03 Capacity of each pump set:- 20.46 LPS
133 28.04 Dia of R/Main:- 120 mtr
134 28.05 Length of R/Main (In metres)
135 28.06 SITE CONDITIONS & WATER CHARACTERSTICS :- TO BE FILLED BY EE WHILE CALLING TENDERS
136 28.07 Location of Site:- To be filled in by Engineer-Incharge before calling tenders
137 28.08 The altitude of place in which the motor is intended to work in ordinary service (in metres) :- To be filled in by Engineer-Incharge
138 28.09 Humidity:- Weather generally remains humid during monsoon season.
139 28.1 Nature of atmosphere:- As normally encounterd in Shivalik Range
140 28.11 NPSH available:- To be filled in by Engineer-Incharge before calling tenders
141 28.12 Detail of quality of water:- To be filled in by Engineer-Incharge before calling tenders
142 28.13 Water free from sand or not :- To be filled in by Engineer-Incharge before calling tenders
143 28.14 Water corosive or not :- To be filled in by Engineer-Incharge before calling tenders
144 28.15 Turbidity (if any):- To be filled in by Engineer-Incharge before calling tenders
145 28.16 Any other information or requirement:-
146 28.17 OPERATING CONDITIONS:- TO BE FILLED BY EE WHILE CALLING TENDERS
147 28.18 Operating frequency:- 50 HZ
148 28.19 Type of current:- AC three/single phase
149 28.2 Rated voltage:- 400 (+/-) 10% volts
150 28.21 No. of working hours per day:- 16 hours
151 28.22 System of earthing if any to to be adopted.:- Double loop earthing as per BIS 3043-1987 latest with upto date ammendments
152 28.23 Speed of revolution in RPM:- To be quoted by tenderer
153 28.24 Direction of rotation:- To be quoted by tenderer
154 28.25 The max. Temp. of cooling air & water in the place in which the motor is intented to work in ordinary service. To be filled in by Engineer-Incharge before calling tenders
155 28.26 MOTOR:-
156 28.27 Ref. to BIS code:- BIS 325-1978 read with BIS 900-1992 (latest)with upto date ammendments
157 28.28 Type of enclosure of motor:- SPDP (as per BIS 4691-1985 (latest)
158 28.29 Type of duty:- Continuous as per IS-12824-1989 or latest with up to date ammendments
159 28.3 Mechanical out put in KW:- Suitable for driving centrifugal pumps required for duties specified against pumps.To avoid overloading of motor a margin of about 15-20% may be kept in the rated out put of prime mover.
160 28.31 Class of insulation:- Class ~B~
161 28.32 Max.permissible temp.rise of motor reqd. if different from given in B(viii) above:- To be filled in by Engineer-Incharge before calling tenders
162 28.33 Particulars of test reqd. & where they are to be conducted:- As per terms & conditions
163 28.34 Particulars as to whether voltage limiting device will be employed:- ATS/star delta starter,oil immersed,fully automatic to be installed between bus bar & motor Shunt capacitor is also proposed to be installed for improving the power factor at site.
164 28.35 (NOTE:- Star delta starter upto 37.5 KW, ATS between 37.5 KW to 50 KW & Stator rotor starter with slip ring motor beyond 50 KW)
165 28.36 Motor whether squirrel cage or slipring:- Squirrel cage/slip-ring
166 28.37 (Note:- Squirrel cage upto 65HP and slipring above 65HP)
167 28.38 Details of shaft extension reqd.:- Just sufficient to provide direct drive by flexible coupling to pump.
168 28.39 Type of slip-ring gear whether continouly rated or for starting purposes only & whether to be fitted with brush lifting or short circuit arrangements or both if interlocks are rquired.:- Continouslly rated for Squirrel cage/ Slipring motor
169 28.4 Breakway torque in terms of rated load torque & the corresponding breakway starting current which may be taken from the supply with the starting apparatus in circuit.:- Breakway torque to be given by the tenderer but the starting current should not exceed 2.5 times of the full load current.
170 28.41 Nature of load & any information regarding the driven machine which has a bearing upon the torque reqd. during the accelerated period, the kinetic energy of the moving parts to be accelrated & No.of starts during a specified period.:- Sufficient to work the pump offered
171 28.42 Where possible fault capacity of the system to which the motor is connected.:- The motor should be able to withstand initial current of 2.5 times the rated current for two minutes without suffering damages or permanent deformations.
172 28.43 PUMP:- BIS 1520-1980 read with BIS 9137-1978 both with up to date ammendments
173 28.44 Nos of pumps reqd.:- 2 no. pumps, one will work at a time ,one stand bye
174 28.45 Spare parts required:- For two years normal maintenance as recommended by manufacturer.
175 28.46 Optional fittings reqd.:- Air cock for exahausting air from each stage.
176 28.47 PUMP OPERATING CONDITIONS:- TO BE FILLED BY EE WHILE CALLING TENDERS
177 28.48 Capacity of each pump set (in LPS) 20.46 LPS
178 28.49 Total head (in Mts).:- 36.61 mtr
179 28.5 If total head is not known then
180 28.51 following details be provided:-
181 28.52 i) Static head ( in mtrs)
182 28.53 ii) Minimum depth of water( in mtrs)
183 28.54 iii) Variation in water level ( in mtrs)
184 28.55 iv) Ground level to max. water level ( in mtrs)
185 28.56 v) Ground level to delivery point ( in mtrs)
186 28.57 vi) Pressure in the suction tank (in Kg/cm^2 )
187 28.58 vii) Pressure in the delivery tank (in Kg/cm^2 )
188 28.59 Length of R/Main (in metres):-
189 28.6 Dia of R/Main (in mm):-
190 28.61 Drive arrangement:- Direct through flexible coupling on a common base plate
191 28.62 Drive type:- Electric driven
192 28.63 NPSH reqd.:- To be quoted by the tenderer
193 28.64 Limits of total head in which the pump is reqd. to operate.:- (-) 15% to (+) 10% of total head.
194 28.65 Suction/ delivery size of pump:- To be specified by the tenderer
195 28.66 Efficiency of pump at:- To be specified by the tenderer
196 28.67 a) duty head (as mentioned at item No.30 (a) )=36.61 mts
197 28.68 b) (+)10 % of head as mentioned at item No.30 (a) =40.27mts
198 28.69 c) (-) 15 % of head as mentioned at item No. 30 (a) =31.11 mtr
199 28.7 Material of construction:- To be specified by the tenderer (manufacturer~s certficate to be appended)
200 29 Supply & fixing at site of suitable direct on line/oil immersed star delta /ATS/ stator rotor starter of standard make such as MEI/Kilburn/Jyoti/ Siemens/Larson & Tubro conforming to BIS-8544-1979 latest with up to date ammendments for squirrel cage/slip-ring motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot,time lag,under voltage release with initial oil filling . 2 Nos
201 29.01 Note:- Star-delta-starter upto 37.5 KW, ATS between 37.5 KW to 50 KW and stater rotor starter with slipring motor beyond 50 KW.
202 30 Providing & fixing at site M.S. sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting i/c the cost of providing and fixing in position the following accessories with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer in charge. 1 No.
203 30.01 Providing & fixing at site Ammeter AC supply,100 mm dia circular dial Auto electric/AE/IMP/Havells make of suitable range for above motor with selector switches conforming to BIS 1248-(P-II)1983 latest with up to date ammendments. 2 Nos
204 30.02 Providing & fixing at site Voltmeter AC supply,100 mm dia circular dial Auto electric/AE/IMP/Havells make of suitable range for above motor with selector switches conforming to BIS 4064-1978 with up to date ammendments. 1 No.
205 30.03 Providing & fixing at site ICTP switches with HRC fuses of Kilburn/Larsen & Tubro/Standard/Siemen/Havells make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediatly after the power meter of HPSEB. 2 Nos
206 30.04 Providing & fixing at site Busbar chamber having three copper bars of suitable rating for full length equal to width of board of three live phases and one copper bar of half rating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date ammendments. 1 No.
207 30.05 Providing & fixing at site ACB/MCB/Oil circuit breaker of suitable capacity of Kilburn/L &T/MEI/GEC/Standard make on incomming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with initial oil filling whenever required & neutral linked under voltage release. 1 No.
208 30.06 Providing & fixing at site Three phase indicating lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with up to date ammendments. 2 Set
209 30.07 Providing & fixing at site Earth leakage circuit breaker/relay of recommended make such as Kilburn/L&T/MET/GEC conforming to BIS-2516-1977 with upto date ammendments and of suitaible range which should have control box, oprating handel and trip/reset push button, on/ off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tap CTS. It should also be fitted earth fault for tripping of breaker on occurance of earth fault on/ of breaker load side. 1 No.
210 30.08 Providing & fixing at site Hour run meter of reputed make of four digit capacity conforming to BIS-722 (latest edition)/ recommendations. 2 Nos
211 30.09 Providing & fixing at site Suitable three phase voltage monitor relay with all protections & usual indicators with electric sirens against single phasing, No/low voltage, high voltage & overloading & phase voltage difference as per IS-3842 with up to date ammendments. 1 No.
212 30.1 Providing & fixing at site Change over Switch of reputed make & suitable capacity 1 No.
213 30.11 Providing & fixing at site Single phase preventor of reputed make & suitable capacity conforming to IS:1248 (P-V)-1983 with up to date ammendments 1 No.
214 31 Supply & fixing at site of Leader/Kirloskar/KSB/Jyoti/Standard/Kilburn/Fouress/Bir/Kartar make cast iron flanged/screwed type foot valve (In case suction lift is involved) for suction pipe having size one or two size larger than suction size of pump such that valocity of flow is not more than 2.50 mtr/sec. with strainer having net area of its openings equal to three to four times of x- sexctional area of flow in suction pipe conforming to BIS 4038-1986 or latest with up to date ammendments i/c all leads & lifts & as directed by Engineer -Inschage 2 Nos
215 32 Providing, laying, jointing & testing at site suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC make from meter of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost i/c cost of carriage of material in all leads & lifts & as directed by Engineer -Inchage.(2x15=30 mtr) 1 Job
216 33 P/L PVC jointless flat water proof cable as per BIS 694-1990 (latest with up to date ammendments) suitable for the pump sets offered from circuite breaker to motor & motor to starter including all other electrical equipments such as thimbles, flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.(2x50=10 mtr) 1 Job
217 34 Providing & laying at site double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt, GI pipes, thimbles, nuts & bolts, digging of pits,GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments.i/c cost of carriage of material in all leads & lifts & as directed by Engineer -Inchage. 1 Job
218 35 Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer) i/c cost of carriage of material in all leads & lifts & as directed by Engineer -Inchage. 2 Nos
219 36 Supply & fixing at site of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 or latest with up to date ammendments. 2 Nos
220 37 P/F double flanged suction, delivery pipe & common header considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers,flanges, rubber gaskets 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of withstanding minimum 1.5 times the total pressure as indicated in item no. 30 (a) or total dynamic pressure + surge pressure whichever is more. The size of suction pipe shall be one or two sizes larger than the suction size of pump such that valocity of flow in suction pipe is not more than 2.50 mtr/sec & delivery pipe shall be of size one size larger than nominal delivery size of pump.i/c cost of carriage of material in all leads & lifts & as directed by Engineer -Inchage. 1 Job
221 37.01 NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge
222 37.02 Main Raw water stage
223 38 Supply, erection, testing & commissioning of submersible pumping set of reputed make such as KSB/BS/Johnston/Worthington conforming to latest relevent BIS code. The pump should be fitted with free flow impellers of bronze /suitable alloy as per BIS 5659 or latest with up to date ammendments suitable for raw/clear water having greased packed bearings & shell with wound stator on motor side & with shaft protection sleeve on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to a submersible squirrel cage electric induction motor of Kirloskar/NGEF/Jyoti / Crompton make conforming to relevent BIS code with up to date ammendments totally dust & water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber chamber & grease packed lubricated bearings & provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor. The pump set should include water level guard, errection clamps, cable clips & depth gauge etc. & suitable for operation on data given below:- 2 set of 83 HP. 2 Set
224 38.01 2 Set of 62 Kw)
225 38.02 (a) Pumps:Specification
226 38.03 I) make :- to be filled by the tenderer
227 38.04 ii) Model= to be filled by the tenderer
228 38.05 iii) No of stages:- to be filled by the tenderer
229 38.06 iv) Material
230 38.07 (Manufactures certificate to be appended (Perfor mance)
231 38.08 I) Head(H) 30 MTR
232 38.09 ii) Discharge 134.03 LPS
233 38.1 iii) Power absorbed.62 KW
234 38.11 iv) Efficiency(n)
235 38.12 v) NPSH
236 38.13 b) Motors.
237 38.14 I)Make
238 38.15 ii) Model
239 38.16 iii) Motor rating
240 38.17 iv) Speed. RPM,
241 38.18 v)Insulation.
242 38.19 I) Discharge(Q) 134.03 LPS, or 482.508 cum/Hr for each set
243 38.2 (2 sets running at a time)
244 38.21 ii) Total dynamic head 30.00 mtrs.
245 38.22 a) LWL in sump well(h) 894.50 mtr
246 38.23 b) Level at discharge point 922.50 mtrs.
247 38.24 c)Discharge head: 28.00 mtr.
248 38.25 e) Static head 28.00 mtrs.
249 38.26 iii) Rising main
250 38.27 a) Length 430 mtrs.
251 38.28 b) dia 450 mm
252 38.29 iv) Pumping hours 16 hours.
253 38.3 v) Altitude of installation above MSL 1460 mtrs.
254 38.31 vi) Characteristices of water. Raw water with sand & silt
255 38.32 a) Temperature 20 0C
256 38.33 b) Ambient temp 30 0C
257 38.34 c) Turbidity 6000 ppm
258 38.35 Centrifugal pumping Machinery of Clear Water Stage.
259 39 Prov. Installation commissioning & testing of Horizontal spindle multistage Centrifugal KSB /M&P/Kirloskar/Jyoti//Beaconwer/BS Make Pump as per BIS 1520-1980 with upto date amendments read with IS 9137:1978 or latest edition suitable for lifting water for under mentioned characteristics with stainless steel/chrommium steel impeller, priming funnels, casing ring and shaft sleeves of steel, shafts of SS:410/AISI431 chromeplated with cast steel/ASTMA-216/CA 6NM Casing Coupled directly through a flexible coupling on a common MS baseplate(baseplate to be from the manufacturer of the pumping unit only) to 1050 KW Squirrel cage screen protected drip proof induction motor make BHEL of 3000 RPM(Synch) and suitable for operation on 11 KV HT 50 Cycles/Second 3 phase AC Electric supply. The power of electric motor/motors should be atleast + 10% in excess of the maximum power required by the pump/pumps in the operation range of (+)10% and (-) 25% of the duty point head. The motor/motors as per IS:325-1978 with uptodate ammendments read with IS:900-1972. The starting currentof motor shall be limited to not more than 4.5 to 5 times of full load current. It should include cost of bearing nuts,bolts and painting etc. and should meet the following requirements: (2X1400 HP=2800 HP) 2800 Each
260 39.01 Disscharge (Q) = 55.60 LPS each pump
261 39.02 Total Dynamic Head = 1091 mtr.,
262 39.03 LWL in sump well(h) = mtrs.
263 39.04 Shaft level = mtrs.
264 39.05 Level at discharge point = mtrs
265 39.06 Suction = Positive
266 39.07 Discharge head = mtrs.
267 39.08 Static head = 1074.75 mtrs.
268 39.09 Rising main
269 39.1 Length 5220 mtrs. (twin paralled lines, 5220 mtrs each line)
270 39.11 Dia = 450mm
271 39.12 Pumping hours = 16 hours
272 39.13 Altitude of installation above MSL 960 mtrs.
273 39.14 Characteristics of water clear could water
274 39.15 Temperature 0 to 30 degree C
275 39.16 Ambient tep = 0 to 35 degree C
276 39.17 Turbility = below 5 JTU
277 39.18 Alkalanity = 170 mg/
278 39.19 Sixe of solids = Nil mm
279 39.2 Others =
280 39.21 Two pumps operating in parrallel shall deliver a discharge of 400.32 Cub meter/hour against 1091 mter total working head.
281 40 Providing & fixing at site Crompton/ Kirloskar/ ABB/ Alsthom (GEC) Control Panel suitable within the permissible limit of starting current as specified in the Indian Electricity Act, for above motor with necessary protections of the following specifications.
282 41 Providing & fixing at site Indoor type vaccum circuit breaker switch board will be suitable for operation at 11 KV 50 Hz 3 phase supply with symmetrical breaking capacity of 150 MVA in solidly earthed natural system. Panel will be sheet steel metal enclosed, dust and Vermin proof ,free standing reinforcement to have level surface resistance to vibration rigidity during transportation and installation. Panel will be suitable for extension and disigned to withstanding the stress which may be set up in dealing with short circuit condition.
283 42 Providing & fixing at site All equipment on front of the panel will be flush/semi flush mounted to present uniform neat appearance. All front mounted equipment as well as equirement mounted inside will be provided with indvidual lables having equipment designation engraved on.
284 43 Providing & fixing at site All internal control wiring will be carried out with 2.5mm sq.size 1.1 KV grade suitable flexible copper conductor with PVC insulation. Panel will be neatly wired and indentification ferrules at all ends. Adequate number of control fuses willl be provided to ensure proper protection.
285 44 Necessary colour code of the control wires will be as per relevant IS specification indicating laps etc. will be provied. Indicating lamps will be suitable for operation at 230V AC supply and protection relyas shall be suitable to operatye at 30 VDC
286 45 Providing & fixing at site Bus bars and connector will be of aluminium and will have adequate cross section to carry out the rated current and will be able to with stand the rated short circuit duty. Bus bars will be supported by expoxy resin cast insulators having adequate creepage distance.
287 46 Providing & fixing at site Power cable boxes will be provided at the rear of the panel to connect 11 KV 3 core Cable of suitable size, and will be suitable for cable entry from the cable trenches below cable boxes will be robust enough and will be self supporting type to carry the weight of power cable inside the cable box so that no undue weight comes on the C.I. Stud.
288 47 Providing & fixing at site Vacuum circuit breaker will be three pole unit design with trip free independent spring charged manually/motor operated closing mechanism. Shunt trip coil for tripping will be suitable for operation at 30 VDC. The spring charge motor shall be suitable to operate at 230 VAC suply.
289 47.01 Indoor switchgear will have a symmetrial and breaking capacity of 150MVA 11 KV and will comprise of the following:-
290 47.02 3 Panel vacuum circuit breaker comprising of the following.
291 47.03 2 Nos. incomer (suitably interlocked mechanically & electrically ) comprising of the following each incomer pannedl will comprise of following.
292 47.04 1 No. 11 KV 150MVA 800 A draw out type vacum circuit breaker complet with opeating meachanism as discribed above.
293 47.05 2 Nos. insolating contacts.
294 47.06 (A) Each pannel comprise of following.
295 47.07 1 Set authomatic safety shutters.
296 47.08 1 set mechanical inter locks
297 47.09 1 Operation counter
298 47.1 1 Shunt trip coil suitable to operate at 30 VDC supply.
299 47.11 1 set of air insulated Albus bar of suiable rating.
300 47.12 3 CT of ratio 800/*5/5A for metering and protection with suitable VA burden accuracy & class-1 & 5 P10
301 47.13 1-PT having ratio 11 KV/3/110V/3/3 phase with suitable vA burnden and accuracy class-1 for metering and protection.
302 47.14 1-Voltmeter 0-12KV with DEF slector switch.
303 47.15 3-Ammeter (0-800A)with suppressed scale from 800A to 1600 Amps.
304 47.16 1-IDMTL 2 element o/c relay having range of 50% to 200% for over current and 1 element E/F relay having range of 10% to 40% type-CDG-31
305 47.17 1-High speed tripping relay type VAJS-13
306 47.18 5-Indicating lamp ON/OFF/TRIP circuit healthy and spring charge indication.
307 47.19 3- Indicating lamp for RYB indication for supply
308 47.2 1- Breaker control switch type Trip/neutral/close.
309 47.21 1- Space heater with thermostat and ON/OFF control switch suitable to operate at 230 V. AC Supply.
310 47.22 2- Push Buttons for trip circuit healthy checks and emergency trip.
311 47.23 1- Cable end box at the rear to connect 11 KV XLPC/PILCA cable of suitable size.
312 47.24 1- Alarm bell.
313 47.25 Breaker will have the following interlocks.
314 47.26 a) Breaker will trip while racking out in close position.
315 47.27 b) Breaker will trip while racking in at close position.
316 47.28 c) Automatic safety shutters will operate whenever Vaccum circuit breaker will be racked out/racked in All steel work will undergo a process of degreasing,Picking in acid,cold rinsing, Phosphatising and then Sprayed with high corrosion resistant primer Final Painting will be done by the applicable of synthetic Enamel paint of approved shades.
317 47.29 1 No. Bus coupler panel same as above but without the following :
318 47.3 i) Overcurrent & Earth fault relays.
319 47.31 ii) All meters &
320 47.32 iii) CT's & PT's.
321 47.33 1 set Providing Power factor correction Panel comprising of the following
322 47.34 A. 11 KV 2 Panel Board Indoor type suitable for operation at 11 KV 50 Hz. 3 Phase supply 150 MVA solidly earthed system. The panel shall be sheet steel metal enclosed dust and virmin proof free standing type suitable for extension and designed to withstanding stressess which may set up in short circuit conditions. The panel shall comprise of the following:
323 47.35 1 No. Incomer Panel 11 KV 150 MVA 400A VCB with manual/motorised spring charged operation & having following
324 47.36 2 Element o/c & earth fault relays CDG-31
325 47.37 Over voltage protection relay
326 47.38 Tripping relay
327 47.39 Ammeter 0-200A with selector switch
328 47.4 Suitable rated 3 phase 11 KV/110 V P.T.
329 47.41 C.T s for protection & metering
330 47.42 (suitably rated)
331 47.43 Suitably wired and protected for capacitors switching ON & OFF duly
332 47.44 All control wiring shall be 1.1 KV Grade & 2.5mm Sq.copper.
333 47.45 2 Nos. outgoing feederes for feeding 2 Nos. 400 KVAR 11 KV capacitor separately as required.
334 47.46 Each out going feeder shall have same operating features and metering CTs selector switches as that of Incomer but without the following
335 47.47 a) Overcurrent & Earth Fault relays.
336 47.48 b) All meters &
337 47.49 c) PT's
338 47.5 Providing 2 Nos. 11 KV 400 KVAR Capacitor stacks suitable for improving Power factor of the system and having independent discharge devices and protective fuses of each capacitor separately.
339 47.51 Acceptable Makes of capacitor Mecheil/BHEL/GEC/L&T /Siemens As per IS:2834-1986 with upto date amendements.
340 47.52 2 Nos. outgoing 11 KV starter feeders rated 400 Amps. 150 MVA & shall be same as that of incomer above, but shall have motor protection relays in place of IDM TL O/C & E.F relays and shall be 200/5/5A for metering & protection and the ammeter shall be of scale 0 to 200 Amps with a suppressed scale upto 600 Amps. Each of the feeders shall also be equipped with suitable surge suppressing units.
341 47.53 1 No. Outgoing feeder shall be same as that of incomer but in addition shall also have over voltage protection relay. The CT ratio shall be 200/5/5A The feeder shall be complete with all respect for capacitor duty Note: The incomer & outgoing feedeer panel against item No.2 & 4 (a)(b) shall be supplied as one 10 panel board.
342 48 P/F of CI Double Flanged sluice valve ISI mark of class-II 250mm dia of Leader/ BHEL /Kirloskar/GLED/ Kilburn/Fouress make on suction side as per the relevant Is code.(For twin R/Mains) 2 Each
343 49 P/F ISI Marked double flanged CS Sluice valve of Leader/BHEL/Kirloskar/KSB/GLED/Kartar Valve/Fouress/AREM make of 250mm dia for the Deliveryside of pump and capable of withstanding the normal seat pressure as per BS:1868 or ASA standard with upto date ammendments Class ASA 900.(for twin rising mains) 6 Each
344 50 P/F ISI Marked double flanged Swing type CS Reflux valve of Leader/BHEL/Kirloskar/KSB/GLED/Kartar valve/Fouress/AREM make of 250mm dia Having bye pass arrangement on the delivery side of pump and capable of withstanding the normal seat pressure as per BS:1868 or ASA standard other relevant IS code with upto date ammendments class-ASA-900 2 Each
345 51 P/F DF MSERW Piping work (Lay out to be approved by Engineer-in-Charge) for suction and delivery pipe suitable of pumps offered for common header as per Rising Main respectively complete with all specials such as Bend, Tees,Reducers,increasers with companion flanges matching with the relevant specification of the accessories including rubber/asbestos gasket of minimum 3mm thickness as per IS:2712-1979 and required number of nuts and bolts as per IS:1364-1983. The pipe shall be as per relevant IS code and to withstanding I.5 times total head stipulated under item No.1. The size of the various compopnents to be as under and will be extented upto 5 mtrs from the outer wall of the pump house in the direction to be joined. 1 Job for 2 Nos. P/Set. 1 Job
346 51.01 i) Suction pipe 250mm dia
347 51.02 ii) Delivery pipe 250mm dia.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail