| 1 | 1 | Dismantling of storage type water heater (Geyser) of 25/35/50 ltrs capacity, any make, vertical or horizontal type, mounted on wall by disconnecting electric and water supply connection and keeping the same in safe custody for carrying out necessary repair/replacement of UNSV parts/ components including descaling of the geyser tank by using proper liquid chemical and re-assambling & refixing the same all as directed by the Engr-in-Charge. (Note: UNSV items for renewal shall be measured and paid seprately under respective itme here-in- after as supply only). | | 400 | Each |
|---|
| 2 | 2 | Supply & fixing following items for water heater and geyser of any type model and make all as directed by Engr-in-Charge. | | 1 | RM |
|---|
| 3 | 2.01 | Rubber washer for fixing the apparatus plate to inner container suitable to existing storage type water heater of same make and size. | | 345 | Each |
|---|
| 4 | 2.02 | Heavy duty PK Aqua 2 feet hot water connection for geyser hose pipe both cold/hot of set water line with adopter and washer at both ends of the pipe. | | 600 | Each |
|---|
| 5 | 2.03 | Clamp for fixing the heating elements to the apparatus plate. | | 160 | Per Set |
|---|
| 6 | 2.04 | Indicator lamp round/rectangular. | | 250 | Each |
|---|
| 7 | 2.05 | Thermostat for geyser 30 to 75 degree centigrade.\nMake: Thecha/DasPass/Victor | | 500 | Each |
|---|
| 8 | 2.06 | Thermal cut out for geyser. | | 50 | Each |
|---|
| 9 | 2.07 | Push type copper heating element of 1.5 KW capacity. | | 500 | Each |
|---|
| 10 | 2.08 | All as per item No 2.07 above but push type 2.00 KW capacity. | | 150 | Each |
|---|
| 11 | 2.09 | Copper Heating element, screwed type, 1.5/2KW capacity. \nMake: Thecha/DasPass/Victor | | 450 | Each |
|---|
| 12 | 2.1 | Cable copper conductor multistranded 3 core PVC insulated of size 40/0076. | | 492 | RM |
|---|
| 13 | 2.11 | Glass wool in between outer cell and container. | | 10 | Kg |
|---|
| 14 | 2.12 | Inner copper container for geyser of capacity 25 ltr, any make any type | | 56 | Each |
|---|
| 15 | 2.13 | Inner copper container for geyser of capacity 50 ltr. | | 45 | Each |
|---|
| 16 | 2.14 | Assemblly for water heater 25 ltr capacity. | | 55 | Each |
|---|
| 17 | 2.15 | Assemblly for water heater 50 ltr capacity. | | 40 | Each |
|---|
| 18 | 2.16 | switch socket combination 5 pin,15 Amp multipurpose | | 700 | Each |
|---|
| 19 | 2.17 | 15 Amp plug Top suitable for 15 amp socket | | 550 | Each |
|---|
| 20 | 2.18 | 2.5 sqmm 3 core copper cable connecting for plug top to Geyser | | 600 | RM |
|---|
| 21 | 3 | M&L for switch piano flush type single pole 15 Amps | | 100 | Each |
|---|
| 22 | 4 | M&L for Socket Outlet 3 pin , flush type 15 Amps | | 100 | Each |
|---|
| 23 | 5 | M&L for modular switch 1 Way 16A, 1 Module | | 25 | Each |
|---|
| 24 | 6 | M&L for modular switch Socket outlet 3 pin , 15A, | | 25 | Each |
|---|
| 25 | 7 | Cleaning of geysers any type and size/make all as specified and directed by Engr-in-Charge. | | 122 | Each job |
|---|
| 26 | 8 | Taking down existing burnt aluminium/ copper sub main wiring and M&L for sub main wiring with two runs of 2.5 Sq mm and one run of 2.5 Sq mm for earth wire with multi standard copper conductors, 1100 volts grade, drawn through and including PVC double locked Casing & caping including complete all as specified and as directed. NOTE:- two runs of 2.5 Sq mm + one run of 2.5 Sq mm and one run of PVC casing & capping and its accessories of suitable size shall be measured as one unit length. | | 525 | RM |
|---|
| 27 | 9 | All as per item No 8.00 here-in-before but with cable size 2.5 Sqmm for one 5 pin 15 Amps socket outlet on independent board and multistranded insulated copper earth contunuity conductor of size 1.5 Sqmm all as specified and directed by Engineer-in-Charge . | | 330 | Point |
|---|
| 28 | 10 | Only Fixing Geyser of any capacity, complete with etc and all accessories and connection | | 125 | Each |
|---|
| 29 | 11 | S & F of metal fasteners of 12mm dia complete as specified and as directed. | | 500 | Each |
|---|
| 30 | 12 | Taking down LT UG cable/service connection of any size and M&L for laying of LT UG cable , XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 16 sq mm, 4 core complete all as specified and as directed. NOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items. | | 200 | RM |
|---|
| 31 | 13 | Taking down LT UG cable/service connection of any size and M&L for laying of LT UG cable , XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 10 sq mm, 4 core complete all as specified and as directed. NOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items. | | 200 | RM |
|---|
| 32 | 14 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in soft/ loose soil complete all as specified ans as directed. | | 64 | Cum |
|---|
| 33 | 15 | Returning filling in trenches including spreading leveling watering and well ramming in layers not exceeding 25 cm thick all complete all as specified ans as directed. | | 34.4 | Cum |
|---|
| 34 | 16 | Removing of excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all complete all as specified ans as directed. | | 29.6 | Cum |
|---|
| 35 | 17 | M&L for fine river washed sand in trenches complete all as specified ans as directed. NOTE: For measurement purpose, punned down thickness shall only be taken. | | 25.9 | Cum |
|---|
| 36 | 18 | M&L for laying brick sub class 'B' old size burnt bricks for cable protection of size 230mmx115mmx75mm complete all as specified and as directed | | 2783 | Each |
|---|
| 37 | 19 | Supply and laying tubes light grade galvanised GI tubing with all fittings, fixed complete to walls/poles/laid in floors/trenchs/road crossing of size 40mm dia bore including taking out unsv GI tubing complete all as specified and as directed. | | 15 | RM |
|---|