83873/E8 Special Repair To Bldg No . P-138 And P-139 ( Small Arms Range ) At Af Stn Mohanbari Under Ge ( Af ) Mohanbari
Tender Overview
Project Description
83873 / E8 Special Repair To Bldg No . P-138 And P-139 ( Small Arms Range ) At Af Stn Mohanbari Under Ge ( Af ) Mohanbari
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 23-May-2020 | Technical Bid Corrigendum | Technical Bid | 25-May-2020 |
| 2 | 25-May-2020 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 01-Jun-2020 |
BOQ
| Name of Work : SPECIAL REPAIR TO BUILDING NO. P-138 AND P-139 (SMALL ARMS RANGE) AT AF STN MOHANBARI UNDER GE (AF) MOHANBARI | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as directed. | item1 | 80 | Cum |
| 2 | 2 | Material and labour for brick work with sub class 'B' bricks straight or curved on plan exc. 6 metres mean radius built in CM (1:6) complete all as specified and as directed. | item2 | 85 | Cum |
| 3 | 3 | Material and labour for Sand filling including watering and consolidation (sand shall be mixed with saw dust, supplied under serial item No.04, laid and levelled as directed without any extra cost) complete all as specified and as directed. | item3 | 300 | Cum |
| 4 | 4 | Supply only Saw dust | item4 | 3000 | Kg |
| 5 | 5 | Excavation over areas not exc. 1.5 metres deep and getting out in soft/ loose soil complete all as specified and as directed. | item5 | 50 | Cum |
| 6 | 6 | Material and labour for broken stone (granite/ basalt) hard core of gauge n.exc 63mm deposited, spread and leveled in layers not exc 15cm thick, watered and rolled, rammed to a true surface complete all as specified and as directed. | item6 | 10 | Cum |
| 7 | 7 | Demolition of PCC in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as directed. | item7 | 16.1 | Cum |
| 8 | 8 | Material and labour for 75mm thick PCC (1:4:8) type D2 (using 40mm graded broken stone aggregate) as in sub base, sub floor, floors and paving complete all as specified and as directed. | item8 | 140 | Sqm |
| 9 | 9 | Material and labour for 40mm thick PCC (1:2:4) type B-1 (using 20mm graded broken stone aggregate) as in floor finished even and smooth with using extra cement complete all as specified and as directed. | item9 | 140 | Sqm |
| 10 | 10 | Material and labour for PCC (1:4:8) type D-2 (using 40 mm graded broken stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed. | item10 | 2 | Cum |
| 11 | 11 | Material and labour for PCC (1:2:4) type B-1 (using 20 mm graded broken stone aggregate) as in coping including use of necessary form work complete all as specified and as directed. | item11 | 4 | Cum |
| 12 | 12 | Returning, filling in, including spreading, levelling, watering and well ramming in layers\nnot exc 25 cm complete all as specified and as directed. | item12 | 87.41 | Cum |
| 13 | 13 | Removing excavated soils to distance exc.250 metres but not ex.500 metres and depositing where directed at a level not exceeding 1.5 metre above the starting point all as specified and as directed. | item13 | 110 | Cum |
| 14 | 14 | Excavation in trenches not exc. 1.5 m wide and not exc. 1.5 m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, laying cable etc. and getting out in soft/ loose soil complete all as specified and as directed. | item14 | 186.2 | Cum |
| 15 | 15 | Taking down cement plaster on brick work or concrete including raking out joints, hacking for key, scrubbing down with water etc complete all as directed. | item15 | 140 | Sqm |
| 16 | 16 | Material and labour for rendering 15mm thick in cement mortar (1:4) on fair faces of brick or concrete surfaces, mixed with integral water proofing compound @ 3% by weight of cement, finished even and smooth without using extra cement complete all as specified and as directed. (Note: Supply only waterproofing compound will be measured and paid separately). | item16 | 180 | Sqm |
| 17 | 17 | Supply only integral water proofing compound. | item17 | 36.396 | Kg |
| 18 | 18 | Material and labour for rendering 15mm thick in cement mortar (1:6) on fair faces of brick or concrete surfaces finished even and smooth without using extra cement all as specified and as directed. | item18 | 40 | Sqm |
| 19 | 19 | Material and labour for preparation of new untreated wall surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of acrylic emulsion paint exterior grade camouflage painting over a coat of primer complete all as specified and as directed. | item19 | 180 | Sqm |
| 20 | 20 | Preparation of new concreted surfaces of walls and applying two coats of oil bound distemper over a coat of chalk whitening complete all as specified and as directed. | item20 | 40 | Sqm |
| 21 | 21 | M&L for preparation of old decorated plastered surfaces of walls and applying one coat of white wash complete all as specified and as directed. | item21 | 20 | Sqm |
| 22 | 22 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including\nNainital or similar pattern roof coverings as applicable complete all as directed. | item22 | 110 | Sqm |
| 23 | 23 | Supply and fix for pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5 mm thick of colour having tensile strength of 550 Mpa as in roof covering to wall fixed with self tapping screws complete all as specified and as directed. | item23 | 100 | Sqm |
| 24 | 24 | Supply and fix for pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.5 mm thick of colour having tensile strength of 550 Mpa as in roof covering to wall fixed with self tapping screws complete all as specified and as directed. | item24 | 10 | Sqm |
| 25 | 25 | Material and labour for 50 mm thick PCC (1:3:6) type C2 (using 40 mm graded broken stone aggregate) as in plinth protection with 12 mm thick joint filled with bitumen mastic complete all as specified and as directed. | item25 | 35 | Sqm |
| 26 | 26 | Material and labour for cement concrete (1:2:4) type B2(using 40 mm graded broken stone aggregate) in surface channels and drains including necessary form work complete all as specified and as directed. | item26 | 4 | Cum |
| 27 | 27 | Taking down chowkats or frames with shutters (without taking off shutters from frame) area exc.1.5 sqm and not exc.4 sqm each complete all as directed | item27 | 1 | Each |
| 28 | 28 | Supply and fix for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified.\n | item28 | 130 | Kg |
| 29 | 29 | Taking down chowkats or frames with shutters (without taking off shutters from frame) area not exc.1.5 sqm each complete all as directed. | item29 | 3 | Each |
| 30 | 30 | Supply and fix for steel windows/ ventilator with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as directed. | item30 | 2.3616 | Sqm |
| 31 | 31 | Material and labour for 3mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane etc complete all as specified and as directed. | item31 | 2 | Sqm |
| 32 | 32 | Supply and fix for PVC connection pipe 15 mm dia and 60 cm long with PTMT nuts complete all as specified and as directed.. | item32 | 1 | Each |
| 33 | 33 | Material and labour for RCC Type B1 (1:2:4) (using 20 mm graded broken stone aggregate) as in slabs supported on walls, beams and columns in floors,roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. | item33 | 0.3 | Cum |
| 34 | 34 | Material and labour for 10 mm dia and over mild steel TMT bars cut to length, bent to shape required including cranking and binding with MS wire (annealed) not less than 0.90 mm dia as in reinforcement complete all as specified and as directed. | item34 | 40 | Kg |
| 35 | 35 | Material and labour for 8mm dia and over mild steel TMT bars cut to length, bent to shape required including cranking and binding with MS wire (annealed) not less than 0.9mm dia as in reinforcement complete all as specified and as directed | item35 | 650 | Kg |
| 36 | 36 | Material and labour for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exc. 200 mm thick for fair finished flat surfaces of concrete all as specified and as directed. | item36 | 4 | Sqm |
| 37 | 37 | Supply and fix in repair vitreous China ware wash hand basin coloured, flat back, size 630 x 450 mm size with pedestal including brackets, cutting for and pinning ends of brackets or erecting stand and brass union with PVC discharge pipe complete all as specified and as directed | item37 | 1 | Each |
| 38 | 38 | Supply and fix in repair 15 mm dia fancy type pillar tap cast copper alloy with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe & fixed complete all as specified and as directed | item38 | 1 | Each |
| 39 | 39 | Supply and fix for 15mm bore fancy type chromium plated stop valves cast copper alloy screwed down high pressure with crutch or butterfly handle in repair. | item39 | 2 | Each |
| 40 | 40 | Supply and fix in repair 10 litres capacity PVC flushing cistern, valveless, syphonic action type, low level white with inlet, ball valve, float and handle complete including brackets and connection to pipe complete including dismantling of existing CI flushing cistern high level incl flush pipe complete. | item40 | 1 | Each |
| 41 | 41 | Supply and fix in repair bib tap for 15 mm bore pipe cast copper alloy fancy type chromium plated with crutch butterfly handle, screwed down for iron pipe or brass ferrule, complete all as specified | item41 | 2 | Each |
| 42 | 42 | Dismantling of floor hearth or wall tiling including cement morter bedding but not backing coat and rubbish off premises etc complete all as specified and as directed. | item42 | 4 | Sqm |
| 43 | 43 | Material and labour for for non skid joint free coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tiles exceeding 0.06 sqm but n.exc 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match etc including 15mm thick sreed bed in CM (1:6) complete all as specified and as directed. | item43 | 4 | Sqm |
| 44 | 44 | Material and labour for glazed ceramic coloured tiles 300x200x6 mm thick as in dado,skirting and vertical surfaces set & jointed neat cement slurry and pointed in white or coloured cement to match the colour of tiles including rendering 10mm thick in CM (1:4) cement plastering to receive the wall tiles complete all as specified and as directed. | item44 | 15 | Sqm |
| 45 | 45 | Supply and fix in repaires vitrious china wash down water closet pedestal pattern white excluding flush pipe flushing cistern etc complete including connection to drain pipe and to flushing pipe etc complete all as specified and as directed. | item45 | 1 | Each |
| 46 | 46 | Supply and fix in repair plastic water closet seat cover black closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device etc complete complete all as specified and as directed. | item46 | 1 | Each |
| 47 | 47 | Taking up or down 15 mm bore steel tubing with all fittings and connections including cleaning for refixing or removal to store complete all as directed. | item47 | 4 | RM |
| 48 | 48 | Taking up or down 20 mm bore steel tubing with all fittings and connections including cleaning for refixing or removal to store complete all as directed. | item48 | 8 | RM |
| 49 | 49 | Supply and fix for 15 mm bore GI tubing 'medium grade' galvanised, with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and as directed. | item49 | 4 | RM |
| 50 | 50 | Supply and fix for 20 mm bore GI tubing 'medium grade' galvanised, with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and as directed. | item50 | 8 | RM |
| 51 | 51 | Supply and fix in repairs for 500 litres capacity, rotational moulded polythelene water storage tanks (ISI marked) (cylindrical vertical with closed top), hoisted and fixed in postion complete all as specified and as directed. | item51 | 1 | Each |
| 52 | 52 | Supply and fix ball valve PTMT 20 mm high pressure with epoxy coated, aluminium rod & high density plastic ball screwed for iron pipe and fixed (minium wt 210 gm), complete all as specified and as directed. | item52 | 1 | Each |
| 53 | 53 | Supply and fix in repair 20 mm dia gun metal globe or gate valves, with iron wheel head screwed both ends for iron pipe complete all as specified and as directed. | item53 | 2 | Each |
| 54 | 54 | Dismantling of timber scantling 40 sqcm and over in section as in unframed work etc complete. All as directed. | item54 | 0.8 | Cum |
| 55 | 55 | Supply and fix for joist channel angle or tee sectionconforming to Fe-290(Gde E-165) fixed independently without connecting plate etc complete complete all as specified and as directed. | item55 | 40 | Kg |
| 56 | 56 | Material and labour for preparation of new steel or iron surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of zinc chrome red oxide primer complete all as specified and as directed. | item56 | 20 | Sqm |
| 57 | 57 | Material and labour for preparation of old treated steel or iron surfaces of any description over 10cm girth or width not otherwise described and applying one coat of synthetic enamel paint complete all as specified and as directed. | item57 | 60 | Sqm |
| 58 | 58 | Material and labour for PCC (1:3:6) type C-2 (using 40 mm graded broken stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed. | item58 | 5 | Cum |
| 59 | 59 | Material and labour for brick work in floor/ tappered wall of drain laid flat with sub class 'B' old size, laid flat bedded and jointed in CM (1:6) and pointed in CM (1:3) complete all as specified and as directed. | item59 | 200 | Sqm |
| 60 | 60 | Material and labour for brick work in floor/ edges of drain laid on edge with sub class 'B' old size, bedded and jointed in CM (1:6) and pointed in CM (1:3) complete all as specified and as directed. | item60 | 75 | Sqm |
| 61 | 61 | Material and labour for plain cement concrete type B-O, (1:2:4) (using 12.5 mm graded broken stone aggregate) in situ in channel of drain, copings etc including form work complete all as specified and as directed.. | item61 | 1.5 | Cum |
| 62 | 62 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc. complete all as specified and directed. | item62 | 170 | RM |
| 63 | 63 | Material and labour for precast cement concrete (1:2:4) type B1 (Using 20mm graded broken stone aggregate) as in cover slab with plain faces and set in cement mortar (1:4) complete all as specified and directed. | item63 | 7.65 | Cum |
| 64 | 64 | Supply and fix for flat iron 40x5mm size as in wind tie including drilling bolting or riveting etc complete all as specified and directed. | item64 | 45 | Kg |
| 65 | 65 | Supply and fix for conventional type onsite LLDPE septic tank designed to carry sewage & sullage water, excavation in any type of soil, PCC (1:4:8) type D2 (using 40mm graded broken stone aggregate) below foundation vent shaft, connection etc for 25 users, capacity complete all as specified and directed. | item65 | 1 | Each |
| 66 | 66 | Soakage wells, excavation, in any type of soil, foundation in PCC (1:3:6), wall of honey combed masonry with top ring of M -25 concrete including intercepting chamber and screen chamber made of brick masonry, RCC cover slab in M-25 inter connecting pipes of RCC complete filled with brick bats, of size 1.2m dia x 3.00m effective depth complete all as shown on drawing No.AF/TD/6/92-1/1 dated 18 Dec 1992. | item66 | 2 | Each |
| 67 | 67 | Supply and fix for 110mm bore PVC(SWR) soil waste and vent pipes single socketed in any length with rubber ring joints laid in floors or trenches including all necessary junctions etc complete all as specified and directed. | item67 | 20 | RM |
| 68 | 68 | Supply and fix for PVC (SWR) 110mm junction (Single T) equal or unequal complete all as specified and directed. | item68 | 1 | Each |
| 69 | 69 | Supply and fix for PVC (SWR) 75 mm junction (Single T) equal or unequal complete all as specified and directed. | item69 | 1 | Each |
| 70 | 70 | Supply and fix for 75mm bore PVC(SWR) soil waste and vent pipes single socketed in any length with rubber ring joints laid in floors or trenches including all necessary junctions etc complete all as specified and directed. | item70 | 10 | RM |
| 71 | 71 | Supply and fix for 110mm PVC (SWR) vent cowl complete all as specified and directed. | item71 | 1 | Each |
| 72 | 72 | S&F 75mm PVC (SWR) vent cowl complete all as specified and directed. | item72 | 1 | Each |
| 73 | 73 | Taking down carefully aluminium point wiring (light, fan, socket or power), complete (fittings such as switches, ceiling rose, pendent, regulators etc) removing material to store for keeping in safe custody or for taking credit and making good disturbed surfaces of wall, floor etc. complete all as directed. | item73 | 15 | Point |
| 74 | 74 | Material and labour for point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core FR PVC insulated and unsheathed multistranded cable 1100 volts grade ISI-694 marked drawn through and including medium grade ISI marked, 20 mm size casinmg capping including all accessories etc, with sunk sheet steel terminal box made out of 1.2 mm thick GI suitable size covered with 3mm thick laminated hylum sheet cover suitable for housing switches, sockets, regulators etc. including one run of FR PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core cable as earth continuity conductor and connecting to the common earth dolly for one light/ fan point controlled by one, one way switch 5 Amps complete all as specified and as directed. | item74 | 11 | Point |
| 75 | 75 | All as per serial item No. 74 here-in-before, but for 3 pin 5 amp switch socket combination on independent board complete all as specified and as directed. | item75 | 3 | Point |
| 76 | 76 | All as per item No. 74 here-in-before but wiring with 2.5 Sq mm FR PVC insulated copper cable for 5/15 amp switch socket combination on independent board and provision of 1.5 Sqmm, FR PVC insulated, multi-stranded, single core copper cable for earth continuity, connected to common earth dolly complete all as specified and as directed. | item76 | 1 | Point |
| 77 | 77 | S&F for switch socket combination 2 in 1, 5/6 Amps flush type 230/240 volt complete all as specified and as directed. | item77 | 3 | Each |
| 78 | 78 | S&F for switch socket combination 3 pin, 15/16 Amps flush type 230/240 volt complete all as specified and as directed | item78 | 1 | Each |
| 79 | 79 | M & L for sub main wiring with 2 run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 2.5 sqmm as earth continuity conductor drawn through and including PVC casing and capping suitable size with all accessories surface type complete all as specified and as directed. (Note:Two runs of main conductor, one run of earth conductor and one run of casing & capping shall be measured and paid as one unit). | item79 | 15 | RM |
| 80 | 80 | Supply & fix for LED tube light along with fixture,18Watt complete all as specified and as directed | item80 | 7 | Each |
| 81 | 81 | S&F for ceiling rose 2 to 3 terminal single (65x50) mm surface type with ISI marked complete all as specified and as directed. | item81 | 4 | Each |
| 82 | 82 | S&F for switch piano flush type 5/6 amps, 240 volt single pole one way complete all as specified and as directed. | item82 | 11 | Each |
| 83 | 83 | Supply & fix for building secuirity light 40 watt endura citylite platinum TGL new generation energy saving & environmental friendly long life versatile presuure die-cast aluminium IP 66 roadway luminaire with high power LED source with acrylic cover complete all as specified and as directed | item83 | 4 | Each |
| 84 | 84 | Supply and fix for street light bracket made out of GI pipe light grade 40 mm dia 1.5 metres long bent to required shape as directed and fixed to bldg complete with two coats of aluminium paint over a coat of red oxide primer including clamps and nut, bolts and washers complete all as specified and as directed. | item84 | 4 | Each |
| 85 | 85 | Taking down MCB of any description complete all as directed. | item85 | 7 | Each |
| 86 | 86 | Supply and fix for MCB single pole and neutral 5 to 32 amps, 240 volt 10 KA, C series complete all as specified and as directed | item86 | 1 | Each |
| 87 | 87 | Supply and fix for MCB single pole 5 to 32 amps, 240 volts 10 KA , C series complete all as specified and as directed | item87 | 6 | Each |
| 88 | 88 | Taking down MCB DB of any type complete all as directed. | item88 | 1 | Each |
| 89 | 89 | Supply and fix for sheet metal enclosures for MCB DB single pole & Neutral 8 Way of double door with 200 Amps rated bus bar complete all as specified and as directed. | item89 | 1 | Each |
| 90 | 90 | Material and labour for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less then 2.25 meter deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth lead wire 4.0mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel and connected to main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 54 cm x 54 cm x 5 cm with one handle for lifting made out of 8mm dia MS bar, funnel, wire mesh, 20 mm bore galvanized steel tubing (medium grade) for watering, filling charcoal or coke and salt in alternate layers, 15mm bore galvanized steel tubing light grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown on electrical plate No.3 of SSR Part-I . (Note: GI earth wire and protection pipe upto 7.5metres shall be deemed to be included in quoted rate) | item90 | 1 | Each |
| 91 | 91 | Supply, laying and testing cable XLPE insulated, screened PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of Size 10.0 Sqmm 2 Core complete all as specified and as directed.. | item91 | 400 | RM |
| 92 | 92 | Material and labour for sand cushioning for protection of underground cable consolidated and compacted with clean dry sand complete all as specified and as directed (Note: Compacted thickness shall only be measured and paid). | item92 | 29.16 | CUM |
| 93 | 93 | Removing excavated material to a distance n.exc 50 metres and depositing where directed at level n.exc 1.5 metres above the starting point all as specified and as directed | item93 | 34.79 | CUM |
| 94 | 94 | Material and labour for well burnt bricks, sub class 'B' bricks, best quality locally available laid flat, dry in trenches for cable protection complete all as specified and as directed. | item94 | 3130 | Each |
| 95 | 95 | LESS SCHEDULE OF CREDIT\n(NOTE : The bidders are required to quote the same amount as inserted in estimated rate column against the group of credit items. For details refer Schedule of Credit including notes therein of tender documents. | item95 | 1 |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender