Special Repair To Replacement Of Lt Oh Line To Ug Cable At Security Post No 04 , 05 , 06 , 07 And 09 Of Dou And Personal Cook House And Living Area Of Mil Hosp And In The Area Of Fmn Offrs Mess , Main Mes Pump House , Mes Ib And Mes Md Accn And Spl , MASIMPUR-Assam

Military Engineer Services-MES has published Special Repair To Replacement Of Lt Oh Line To Ug Cable At Security Post No 04 , 05 , 06 , 07 And 09 Of Dou And Personal Cook House And Living Area Of Mil Hosp And In The Area Of Fmn Offrs Mess , Main Mes Pump House , Mes Ib And Mes Md Accn And Spl . Submission Date for this Tender is 02-06-2020. Overhead Line Tenders in MASIMPUR Assam. Bidders can get complete Tender details and download the document.




Tender Notice

24246464
Corrigendum : Special Repair To Replacement Of Lt Oh Line To Ug Cable At Security Post No 04 , 05 , 06 , 07 And 09 Of Dou And Personal Cook House And Living Area Of Mil Hosp And In The Area Of Fmn Offrs Mess , Main Mes Pump House , Mes Ib And Mes Md Accn And Spl
Open Tender
Indian
Assam
MASIMPUR
02-06-2020

Tender Details

Special Repair To Replacement Of Lt Oh Line To Ug Cable At Security Post No 04 , 05 , 06 , 07 And 09 Of Dou And Personal Cook House And Living Area Of Mil Hosp And In The Area Of Fmn Offrs Mess , Main Mes Pump House , Mes Ib And Mes Md Accn And Spl Repai

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 14-May-2020 BOQ REVISED BOQ 26-05-2020
2 26-May-2020 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 02-06-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 84000.0 /-
Tender Value
INR 42 Lakhs /-

BOQ Items

SPECIAL REPAIR TO REPLACEMENT OF LT OH LINE TO UG CABLE AT SECURITY POST NO 04, 05, 06, 07 & 09 OF DOU AND PERSONAL COOK HOUSE AND LIVING AREA OF MIL HOSP AND IN THE AREA OF FMN OFFRS MESS, MAIN MES PUMP HOUSE, MES IB AND MES MD ACCN AND SPL REPAIRS FOR REPLACEMENT OF HPSV/HPMV LIGHT FITTINGS INTO LED LIGHT FITTINGS AT SRIKONA TCP AND KALIBARI TCP AND CERTAIN REVENUE WORKS AT MASIMPUR MIL STN UNDER GE SILCHAR
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Dismantling of existing unserviceable /undersize ACSR conductor (of any size), jumper from overhead line, removing unserviceable materials from site of work complete all as specified and directed. 9.7 Qtl
2 2 Dismantling under size/defected cross-arms of M.S. channel or angle of any sections complete all as specified and directed. 5.5 Qtl
3 3 Dismantling of unserviceable insulator of any size/type complete all as specified and directed. 360 Each
4 4 Dismantling of earth wire/craddle/stay/ service distributon feeder complete all as specified and directed. 1.5 Qtl
5 5 Supplying, laying, connecting and testing XLPE insulated, PVC sheathed, armoured LT electric power UG cable (heavy duty with stranded aluminum conductor) of size 120 sqmm, 3.5 core, 1100 Volts(Earthed) grade, confirming to IS-7098 (Part-II) laid through duct/ pipe / in trench etc. with cable glands & suitable size of aluminium lugs complete all as specified. \nNote : Earth work, brick protection and sand cushioning and GI Pipe shall be measured and paid separately under respective item. 100 Rm
6 6 All as per item No. 5 above but with 95 sqmm 3.5 core cable. 450 Rm
7 7 All as per item No. 5 here in before but with 70 sqmm 3.5 core cable. 150 Rm
8 8 All as per item No. 5 here in before but with 50 sqmm 3.5 core cable. 771 Rm
9 9 All as per item No. 5 here in before but with 25 sqmm 4.0 core cable. 350 Rm
10 10 All as per item No. 5 here in before but with 16 sqmm 4.0 core cable. 1360 Rm
11 11 Supply, installation, testing and commissioning, CPRI approved factory made and tested, LT feeder pillar box, outdoor type of size 1000mm x 800mm x 300mm, platform mounted. The panel shall be dust and vermin proof, IP65 class protection and madeout of 3.00 mm thick CRCA MS Sheet and 50x50x5mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front opening type, with aprons for cable entry, with double door shutter and locking arrangement, internal wiring with 2.5 sqmm PVC insulated, stranded copper conductor cable, IS-694 marked of adequate size and internal connection from MCCBs, MCBs and TPN aluminium bus bar and extension links of rating not less than 1.5 times the rated capacity of the respective MCCBs. The TPN bus bar and extension links shall be insulated with colour code heat shrinkable sleeve and shall be mounted epoxy regin insulator to contactor not less than 10 sqmm single core copper cable stranded copper conductor cable, IS-694 marked. The following items accommodated with this feeder pillar including 02 Nos danger notice plate made of 1.6mm thick mild steel sheet, vitreous enamelled white of size 25 x 20cm with letter figures and conventional skull bones in signal red colour and fixed nuts, bolts and washers etc with voltage and danger indicated in Hindi and English complete all as specified and directed. The scope of work includes the following items accommodate the same panel:-\n(a) MCCB 4 pole, 415 volts AC grade, 160 Amps, 25 kA Icu = 100% Ics - 01 No\n(b) Digital type Voltmeter (0-500 V) with selector switch - 01 No\n(c) LED RYB phase indicators lamp - 01 Set 12 Each Job
12 12 Supply and laying GI tubing 50mm bore light grade with fittings laid in trenches or for road crossing for protection of LT underground cables complete all as specified. \n 120 Rm
13 13 Material and labour as in replacement for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of size 25mmx4mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate, 50mm thick precast RCC 1:2:4 cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and directed. 19 Each
14 14 Excavation in trenches not exceeding 1.50 m wide and not exceeding 1.5 m in depth for foundation of poles, cable etc, not exceeding 10 sqm on plan and getting out in soft/loose soil including taking out brick protection etc complete all as specified and directed. 744 Cum
15 15 Material and labour for sand filling around the cable with approved quality coarse and for sand cushioning for under ground cable including spreading and puning down desired thickness compete all as specified.\nNote :- Thickness of sand cushion after punning down will be measured and paid. 240 Cum
16 16 Material and labour for brick protection cover to underground cable with sub class "B" over brunt brick (locally available best quality) laid dry and flat abutting each other with gaps not exceeding 10mm complete all as specified. 21806 Each
17 17 Returning, filling in with soil obtained from excavation including spreading levelling watering and well ramming in layers not exceeding 25 cm complete all as specified. 338 Cum
18 18 Removing excavated material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified. 452 Cum
19 19 Material and labour for boring of hole under roads with mechanical arrangement upto 80 mm dia without disturbing the top surface of the road for passing the cable across the road complete all as specified. 70 Rm
20 20 Material and labour for LT jointing kit epoxy based suitable for 95 sqmm 3.5 core cable. 8 Each
21 21 Supply and fix shock proof and rust proof pole mounted junction box of size 250mm x 200mm x 105mm with connector suitable for poles mounted three phase 4 wire high wattage LED based lighting system with 1 x SP 6 Amp MCB complete all as specified.\nMake:- Sintex model No. GS-JB-2520 or equivalent make approved by GE.\n 28 Each
22 22 Supply and connect and drawn through pole PVC insulated and sheath stranded aluminum conductor 4 sqmm, 2 core cable for connection of street light fitting connector to pole junction box including necessary hole on LT pole complete all as specified. 80 Rm
23 23 Supply and fix LT over head lines of aerial bunched cable (ABC) on 9 meter sweged steel tubular poles with XLPE insulated at Aerial bunched cable 3 core x 50 sqmm + 1 core x 35 sqmm complete with all fittings all as specified and as per latest IS specification. 280 Rm
24 24 Taking down existing HPSV/HPMV metal halide light fittings/flood lights of various capacity including all fittings and fixtures. 9 Each
25 25 Supply and fix LED flood light fitting 200 watt, 230 VAC, pressure die cast with IP 66 protection, efficient high output emitter LED for better distribution with required MS angle, nuts, bolts, PCC work necessary at site all as specified.\nMake:- Havells Cat No. JETAIRISPLUSFLS200WLED7575PSYMLTG or equivalent make of Philips/Bajaj/Crompton Greaves 4 Each
26 26 Supply and fix LED flood light fitting 150 watt, 230 VAC, pressure die cast with IP 66 protection, efficient high output emitter LED for better distribution with required MS angle, nuts, bolts, PCC work necessary at site all as specified.\nMake:- Havells Cat No. JETAIRISPLUSFLS150WLED757PSYMLTG or equivalent make of Philips/Bajaj/Crompton Greaves 5 Each
27 27 Supply and fix Flurescent tube light fitting Flame proof type FLP-WP of T5 2x28W including integral reflector made of alluminium alloy LM6, with electronic ballast, bipin holders, connector block etc and all accessories pre -wired and including connecting up with twin core twisted flexible copper conductor with suitable size all as specified. 4 Each
28 28 Material and labour for point wiring with FRLSH 1.5 sqmm multi stranded PVC insulated and unsheathed copper conductor (FRLSH) drawn in through in stove enamelled steel conduit will all accessories such as saddles, screws, plastic guties etc fixed on PVC terminal box to wall/roofs/ceiling etc on surface and incl provision of cable 1.5 sqmm PVC insulated unsheathed multistranded copper conductor (FRLSH) to common earth conductor as earth continuity conductor connected to earth dolly complete with all accessories and all as specified. 4 Per Point
29 29 Supply and fix Flame proof switch socket & Plug combined in LM6 cable termination box in LM6, 16 Amp, 250 Volt, 2P + earth complete all as specified. 4 Each
30 30 Supply and fix FLP/WP switch/Isolator 16 Amp double pole ON/OFF rotary switch with cable termination box in LM6 complete all as specified. 1 Each
31 31 Supply and fix FLP/WP switch/Isolator 16 Amp single pole ON/OFF complete all as specified. 1 Each
Disclaimer :