Dnit Chargeable To Rural Nrdwpwqm And S ( Ambala Phed ) Supplying Of Laboratory Instruments To Make Ph Lab At Ambala Cantt Upto Nabl Accreditation And All Other Works Contingent Thereto . , PHED LAB AMBALA CANTT-Haryana

Public Health Engineering Department-PHED has published Dnit Chargeable To Rural Nrdwpwqm And S ( Ambala Phed ) Supplying Of Laboratory Instruments To Make Ph Lab At Ambala Cantt Upto Nabl Accreditation And All Other Works Contingent Thereto . . Submission Date for this Tender is 15-05-2020. Laboratory Equipment Tenders in PHED LAB AMBALA CANTT Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

24236566
Dnit Chargeable To Rural Nrdwpwqm And S ( Ambala Phed ) Supplying Of Laboratory Instruments To Make Ph Lab At Ambala Cantt Upto Nabl Accreditation And All Other Works Contingent Thereto .
Open Tender
Indian
Haryana
PHED LAB AMBALA CANTT
15-05-2020

Tender Details

Dnit Chargeable To Rural Nrdwpwqm And S ( Ambala Phed ) Supplying Of Laboratory Instruments To Make Ph Lab At Ambala Cantt Upto Nabl Accreditation And All Other Works Contingent Thereto .

Key Value

Document Fees
INR 1000 /-
EMD
INR 18100.0 /-
Tender Value
INR 9.05 Lakhs /-

BOQ Items

NAME OF WORK: DNIT chargeable to : Rural NRDWP-WQM&S (Ambala PHED). "Supplying of Laboratory Instruments to make PH Lab at Ambala Cantt upto NABL accreditation & all other works contingent thereto". Amount Rs. 9.05 Lacs Time Limit 2 Months.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Supply of UV-Visible Spectrophotometer Pre- Programmed Water analyser complete in all respect. Make-HACH-Model-6000 (with calibration certificate). Technical specification given as under:- Parameters Specifications Wavelength range 190 – 1100 nm (scan range) Optics Monochromator with grating and step motor / reference beam Lamp Xenon Flash Lamp (500 million flashes possible) with five years warranty Display Backlit 7” colour display for extensive graphical evaluation Operation Membrane Keyboard (Alpha Numeric Membrane Keypad) Stray Light < 0.05 % Transmission at 340 and 408 nm Bandwidth 4mm Measurement concentration, single and multi-wavelength measurement of absorbance and % transmission, kinetics, spectra Turbidity correction The instrument shoud have automatic turbidity correction in Conc. Mode Scan speed 700–2000 nm/min, Scans in 1, 2, 5, 10 nm steps of wavelength range Wavelength accuracy/Reproducibility ± 1 nm / < 0.5 nm Photometric accuracy/Reproducibility – 0.003 E for E < 0.600; 0.5 % of values for 0.600 < E < 2.000 Cuvette 16 mm round, 10 mm, 20 mm, 50 mm rectangular with automatic detection w/o adapter additional 13mm and 24 mm cells could be used Bar code Automatic method recognition including measurement range for all cuvettes, external bar code reader could be added Technical specification given as under:- Data storage 5000 measurement values, spectra and kinetics approx. 40 MB => 500 spectra (300–900 nm) and 400 kinetics with 150 measurement values Methods and profiles > 150 pre-programmed methods, 100 user-defined methods, comprehensive programming options , Instrument should be preprogramed for Iron analysis at 510 nm with 1,10 Phenanthroline method as per APHA, Instrument should be preprogmmed for DO atleastupto 10ppb-800ppb. Sulphate upto 1000 ppm, Manganese, Chlorine, COD from 0 - 15000 ppm and other water analysis parameters Interface/update 1 USB-A, 1 USB-B, 1 Ethernet(LIMS Connectivity ASCII,.CSV-files),External Barcode Reader and Scanner/ Update via Internet and USB stick IP Class IP 30 including drainage in optical compartment Temperature Range Operation: +10 °C to +35 °C, Storage: –25 °C to +65 °C Device Check (Validation facility of Instrument and method) Instrument should have internal Anaytical quality assurancesystem with additional options for customising the Analytical quality assurance tools, AQA with conjunction of method and AQA for photometric determination other ingredients in sample Certification Instrument must have ISO certification for production for water testing kits and instruments from manufacturer CE CE Conformation as per EU guidelines Wavelength Wavelength (NM) should be displayed while measurement of sample in concentration mode Stray light correction at 340nm GG375 filter tolerance of T should be 0.04-0.026% Neutral density filter Neutral glass F2 at 546nm should be less than ± 0.24 ABS to ± 0.003 ABS Technical specification given as under:- Built-in Security Level Device supports the assignment of passwords and assignment of upto 3 different user levels(Guest,User,Admin) Manual Hard Copy of Manual all the Pre-programmed methods test procedure with working principle of Instrumert Do's and Don't during the analysis interference study and barcoding of all the test procedure with pictorial diagram should be in the manual Barcode Reader External Barcode Reader Required to Scan the Preprogrammed Methods test Procedure item1 1 No.
2 2 Supply of Water Purification System :- Water Purification system for preparation of Mobile phase and standards with following specifications should be quoted.Pre-filtration system: Three stage pre-treatment system with 10, 5 & 1 micron spun filters for removal of suspended particles and to take care of F.I in water. Microprocessor - controlled management systems for continuous monitoring of water purity. Should produce Ultra-Pure water ( Type 1 ) from tap water for different applications. It should be single stage system with the filter at the tap with bacteria <0.1 CFU/ml Should have RO, DI and UV in a single unit. It Should have an integrated docking vessel of 25 litre for storing the water to save space It should have recirculation facility to maintain consistent peak water purity. Instrument should show water volume in reservoir graphically and in percentage. It should have cartridge change indicator. The production rate of the unit should be minimum 7 Litre/hr or more and the dispense rate should be minimum 1.0 L/min It should have dual wavelength UV (185/254 nm) The manufacturer must have worldwide presence (with calibration certificate). Techncial Specification:- ·         Dist. Water output Capacity 1.5 ltr/hr ·         Minimum Cooling water requirement 1 l/min ·  Total Power Consumption:- 3 KW ·   Conductivity:- 1X10 raise to power 6 ·  Voltage:- 230 to 250 · Biological Acitivity:- Pyrogen Free ·         Boiler:- Quartz ·         Condensor:- Quartz ·         All glass part are of quartz glass NOTES :- i) AMC/CMC any type of part of instruments shall be cover within 2 years of warranty. ii) GST extra applicable as per Govt. Rules. item2 1 No.