Improvement Of Efficiency Of Water Supply Installation By Rep/Replacement Of Spare Parts Of Motor , Star Delta Starter , Apfc Panel , Air Compressor , Rewinding Of Pumps/Motors And Other Equipment At Mil Stn Pithoragarh Under Ge Pithoragarh, Pithoragarh-Uttarakhand

Military Engineer Services-MES has published Improvement Of Efficiency Of Water Supply Installation By Rep/Replacement Of Spare Parts Of Motor , Star Delta Starter , Apfc Panel , Air Compressor , Rewinding Of Pumps/Motors And Other Equipment At Mil Stn Pithoragarh Under Ge Pithoragarh. Submission Date for this Tender is 11-06-2020. Spare Part Tenders in Pithoragarh Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

24229609
Corrigendum : Improvement Of Efficiency Of Water Supply Installation By Rep/Replacement Of Spare Parts Of Motor , Star Delta Starter , Apfc Panel , Air Compressor , Rewinding Of Pumps/Motors And Other Equipment At Mil Stn Pithoragarh Under Ge Pithoragarh
Open Tender
Indian
Uttarakhand
Pithoragarh
11-06-2020

Tender Details

Improvement Of Efficiency Of Water Supply Installation By Rep/Replacement Of Spare Parts Of Motor , Star Delta Starter , Apfc Panel , Air Compressor , Rewinding Of Pumps/Motors And Other Equipment At Mil Stn Pithoragarh Under Ge Pithoragarh

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 18-May-2020 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 25-05-2020
2 26-May-2020 corrigendum 2 Date 02-06-2020
3 03-Jun-2020 corrigendum 3 Date 11-06-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 56000.0 /-
Tender Value
INR 28 Lakhs /-

BOQ Items

Name of Work: IMPROVEMENT OF EFFICIENCY OF WATER SUPPLY INSTALLATION BY REP/REPLACEMENT OF SPARE PARTS OF MOTOR, STAR DELTA STARTER, APFC PANEL, AIR COMPRESSOR, REWINDING OF PUMPS/MOTORS AND OTHER EQUIPMENT AT MIL STN PITHORAGARH UNDER GE PITHORAGARH
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Material and Labour in replacement of single phase preventor (supply monitoring device), 415V, 3P3W, 50 hz including electric connection complete all as specified and directed. \nMake- L&T (as per sample) or equivalent make 2 Each
2 2 Material and Labour in replacement of Contractor MNX 32A, 3P and Front Mounting Add-on aux. Contact Block MNX 2 NO + 2 NC Make- L&T 2 Set
3 3 Material and Labour in replacement of Over load relay 20-30A, MN2 Make- L&T 2 Each
4 4 M&L including jointing and testing of CI wedge gate sluice valves of 150mm dia class 150, PD Type,bolted bonnet outside screw & Yoke type rising stem, ISI marked, flanged ends, drilled having stainless steel spindle with cast iron wheel at top complete with nut bolts, washer and rubber gasket complete all as specified .\nMake : SANT/KIRLOSKAR/LEADER 2 Each
5 5 Supply & Fixing in replacement Automatic star delta starter factory made , floor mounted, made of CRCA sheet powder coated 2.0 mm, detachable type fixed with nuts and bolt and front door fixed with hinges and knobs, suitable for 3 phase 415 volts, 50Hz AC supply complete as as specified and directed comprising of the following :- \n(a) MCCB 315 Amp 35KA TP(Make- L&T/Schenider) - 01No\n(b) Single Phase Preventor (Make- L&T/Schenider)-01 No\n(c) Bimetal overload Relay (90-150Amp) (Make- L&T/ Schenider)- 01 No\n(d) Indicating light On,Off (Make- L&T/Schenider)– 02Nos\n(e) Phase indicating lamp R,Y,B (Make- L&T/Schenider)-03Nos\n(f) Digital Amp Meter (0-300Amp) (Make- L&T/Schenider)-01 No\n(g) Digital Volt Meter (0-500 Volts) (Make- L&T/Schenider)-01 No \n(h) Amp Meter Selector Switch (Make- L&T/Schenider) – 01 No\n(i) Volt Meter Selector Switch (Make- L&T/Schenider)– 01 No\n(j) C.T. 300/5 (Make – AE)– 03 Nos\n(k) Motor protection automation phase sequence corrector time delay circuit single phase preventor with facility to change over from automatic to manual with contactors upto 150 HP motor, protection fuse etc.(Make-Universal switch gear control/ Tricolite/BCH)-01 No 2 Each
6 6 Material and Labour in replacement of three pole contactor ML 12 suitable for 150/100HP star delta starter including electric connection complete all as specified and directed. \nMake-L&T or equivalent in HPL/Havells 6 Each
7 7 Cutting of bushes , grass, small trees at water supply installations or where directed as per requirement and disposal of the same to a distance not exceeding 50 mtr all as directed. 1000 Sqm
8 8 Supply and laying in replacement of high voltage insulation mat (blue in colour) made of elastomeric polymers material having a high insulation resistance, thus imparting total safety of human being from any leakage current, having high insulation resistance of class B of size 2.5 mm thick and 1.0 m width LT grade confirming to IS - 15652 : 2006, including pasting of mat with SR-998 by adding thinner as per requirement complete all as specified and directed. Make- Jyoti / Electrosafe / Vardhman 35 SQM
9 9 Taking down existing alum mixing gear mechanism & motor from base, overhauling, greasing, servicing complete and fitting back after repairing of PCC (1:3:6) Base of size 0.60mx0.40mx0.10m .all as directed 1 Each Job
10 10 Material and Labour for dismantling of main gear box assembly mounted on sedimention tank and cleaning, overhauling,greasing and replacement of gear oil approx 10 ltr , lathe work on Gear drum/pininon and shaft wheel gear with proper alignment and refixing in same location including testing complete all as directed. 1 Each Job
11 11 Material and Labour for dismantling of sluice valve spindle clear stainless steel assembly complete with opening of nut & bolt with long handle with lathe work and replacement of gland/packing to repair leakage from valve of size 300/150mm including replacement of spandle assembly complete all as directed. 2 Each Job
12 12 M & L for preparation of old painted surface of panels- 5 Nos, 150mm pipe lines- 30Mtr, railing and Chaqured plate- 20 Nos etc and protect meters, switches, duct cover from painting and paint with spray gun with one coat of existing paint complete all as specified and directed 60 Sqm
13 13 M & L for preparation of old painted surface with the help of paint remover, scrapper & fine ambery paper and painting with tow coat of heat resistance paint with the help of spray gun on 150/120/100 HP Centrifugal pump set including motor, and writing SM No/ Maching No and connect back all Electrical connection and testing complete all as specified and directed. 8 Each Job
14 14 M & L for preparation of old painted surface with the help of paint remover, scrapper & fine ambery paper and painting with tow coat of heat resistance paint with the help of spray gun on 30/12.5 HP Centrifugal pump set including motor, and writing SM No/ Maching No and connect back all Electrical connection and testing complete all as specified and directed. 6 Each Job
15 15 M & L for preparation of old painted surface with the help of paint remover, scrapper & fine ambery paper and painting with tow coat of heat resistance paint with the help of spray gun on 5/1/.5 HP Centrifugal pump set including motor, and writing SM No/ Maching No and connect back all Electrical connection and testing complete all as specified and directed. 6 Each Job
16 16 Material and Labour for preparation of old painted surface and applying one coat of synthetic enamel paint ( existing colour ) first quality on NRV /Sluice valve of any size complete all as specified and directed. \n 26 Each Job
17 17 Material and Labour for disconnecting motor 150 HP all electrical connections , removing the motor from the base and opening up the motor carefully and cleaning, servicing,greasing including varnishing complete, heating, replacement of worn out bearing with new bearing and reassembling, mounting the same,including testing on full load up to entire satisfaction, complete all as directed .\nNote:- (i) The cost of bearing as per sample deemed to be included in the quoted rates. \n (ii) other Spare parts shall be measured and paid separately under respective items 2 Each Job
18 18 All as per Item No 17 above but 125 HP 2 Each Job
19 19 All as per Item No 17 above but 120 HP 2 Each Job
20 20 All as per Item No 17 above but 100 HP 2 Each Job
21 21 All as per Item No 17 above but 30/25 HP 1 Each Job
22 22 All as per Item No 17 above but 3/5 HP 1 Each Job
23 23 All as per Item No 17 above but 0.5/1.0 HP 1 Each Job
24 24 Material and Labour for disconnecting all electrical connections , removing the pump 150 HP from the base and opening up the pump carefully and overhauling , cleaning, servicing, greasing and including replacement of worn out bearing,worn out gland bush,and reassembling, mounting the same, including testing on full load up to entire satisfaction , complete all as directed.\nNote:- (i) The cost of bearing as per sample deemed to be included in the quoted rates. \n (ii) other Spare parts shall be measured and paid separately under respective items 2 Each Job
25 25 All as per Item No 24 above but 125 HP 2 Each Job
26 26 All as per Item No 24 above but 120 HP 1 Each Job
27 27 All as per Item No 24 above but 100 HP 2 Each Job
28 28 All as per Item No 24 above but 30/25 HP 2 Each Job
29 29 Supply only grease all as specified and directed Make- Servo 5 Kgs
30 30 Supply only Gland of Size 10mm all as specified and directed 10 Kgs
31 31 Supply only Gland of Size 12mm all as specified and directed 10 Kgs
32 32 Supply only Gland of Size 14mm all as specified and directed 10 Kgs
33 33 Dismantling and servicing the complete unit of automatic servo stabilizer oil cooled type 3 phase, 440 Volts 50 Hz including disconnecting & taking out oil from oil cooled stabilizer capacity 30 KVA Make- paradise including cleaning & segregating the unserviceable/serviceable parts, servicing, oiling, greasing of mechanical mechanism at operation complete all as directed including cleaning of inner surface of oil tank. Nuts, bolts, washers, packing etc. of required size and screws shall also deemed to be included in this work. This work shall not include cleaning old transformer oil, dehydrating & filtration machine and refilling the treated oil in tank andwhich shall be paid under appropriate item. Testing of stabilizer shall be carried out after repair at full load for manual/automatic operation & for corrected out put at variable input (within permissible limit) and cut off operation at low voltage complete all as specified and directed. \n 1 Each Job
34 34 All as per item No. 33 above but for air cooled automatic voltage stabilizer 3 phase 440 Volts having capacity 10 KVA servo type complete all as specified and directed.\nMake: Nayar Power Control or equivalent. 1 Each Job
35 35 All as per item No. 33 above but for oil cooled automatic voltage stabilizer 3 phase 440 Volts having capacity 05 KVA servo type complete all as specified and directed.\nMake: Blue bird or equivalent 1 Each Job
36 36 S&F in replacement of Automatic phase sequence corrector with automatically correct input supply, Reverse Phase and also protection gainst single phasing, voltage unbalancing, low voltage high voltage with time delay motor upto 25 to 30 HP complete all as specified and directed 1 Each
37 37 Supply and Fixing in replacement of PVC insulated unsheathed multi stranded copper conductor cable 1100 volts grade single core of 120 Sqmm size from LT panel to starter and starter to motor including crimping of copper lugs -06 nos, complete all as directed.\nMake-Havells/Polycab/Finolex 130 RM
38 38 All as per Item No 37 above but 150 Sqmm size complete all as directed.\nMake-Havells/Polycab/Finolex 80 RM
39 39 Supply and Fixing in replacement Off load changeover 400/315A 4 Pole 415volts , 50Hz with suitable side handle complete all as specified and directed. 1 Each
40 40 Supply and Fixing in repair neon blub indicating lamp assembly complete all as directed. 6 Each
41 41 Supply and Fixing in repair suitable selector switch for ammeter/voltmeter complete all as directed. 6 Each
42 42 Supply and Fixing in replacement Digital type Volt meter (0-500V) flush mounted three phase class 1.0 size of size 96x96 sqmm complete all as specified and directed. \nMake-AE/HPL/IMP 2 Each
43 43 All as per Item No 42 above but Digital Type (0-600A) Amp meter 2 Each
44 44 Supply and Fixing in replacement of Current transformer (CT) of range 100/5 A complete all as specified and directed. Make-AE/Crompton/Pragati 1 Set of three
45 45 Material and Labour for Earthing complete with galvanized steel earth plate electrode, 600X600X 6 mm thick, buried directly in ground (earth pit not less than 2.25 Mtr deep below ground level) with top edge of the earth plate not less than 1.5 Mtr below normal ground level, connected to galvanized earth strip 32x6 mm by means of galvanised iron or steel all as shown in electrical plate No. 3 on SSR Part I connected to elelctrical equipments all as directed or indicated including Excavation & earth work, construction of PCC pit with RCC cover, watering pipe 20mm dia light grade with funnel & wire mesh & testing all as directed. 2 Each Job
46 46 Supply and Fixing in replacement GI strip 32 x 6 mm complete laid in trenches / ducts fixed on steel structure complete all as specified and directed. 20 RM
47 47 Material and Labour for opening up the motor 150 HP carefully and removing burnt windings from stator and rewinding with suitable gauge of supper enamelled copper insulated wire and superior insulating material including varnishing, heating, greasing replacement of worn out bearing, reassembling the same,including testing on full load up to entire satisfaction, complete all as directed .. 2 Each Job
48 48 All as per Item No 47 above but 125 HP 2 Each Job
49 49 All as per Item No 47 above but 100 HP 2 Each Job
50 50 All as per Item No 47 above but 30/25 HP 2 Each Job
51 51 All as per Item No 47 above but 12.5 HP 1 Each Job
52 52 All as per Item No 47 above but 3/5 HP 1 Each Job
53 53 All as per Item No 47 above but 0.5/1.0 HP 1 Each Job
54 54 Supply and fixing in replacement of MS coupling set including rubber bush and MS bolts suitable for 100 to 150 HP Pump complete all as directed. 1 Each Job
55 55 S&F in replacement MS coupling set suitable for 30/25 HP Pump complete all as directed. 1 Each Job
56 56 S&F in replacement rubber coupling suitable for 12.5 HP Pump complete all as directed. 1 Each Job
57 57 S&F in replacement rubber coupling suitable for 30/25 HP Pump complete all as directed. 1 Each Job
58 58 S&F in replacement of coupling rubber bush -12Nos with MS bolts suitable for 100 to 150 HP Pump complete all as directed. 2 Each Job
59 59 S&F in replacement pump bearing No NU210 complete suitable for 100 to 150 HP \nMake- NBC 2 Each
60 60 S&F pump bearing No 7310 complete suitable for 100 to 150 HP \nMake- NBC 8 Each
61 61 S&F pump bearing No 2310 complete suitable for 100 to 150 HP \nMake- NBC 2 Each
62 62 S&F motor bearing No NU316 complete suitable for 100 to 150 HP \nMake- NBC 2 Each
63 63 S&F motor bearing No 6316 complete suitable for 100 to 150 HP \nMake- NBC 1 Each
64 64 S&F motor bearing No 6315 complete suitable for 100 to 150 HP \nMake- NBC 1 Each
65 65 S&F motor bearing No 6317 complete suitable for 100 to 150 HP \nMake- NBC 1 Each
66 66 S&F motor bearing No 6310 complete suitable for 25/30 HP \nMake- NBC 1 Each
67 67 S&F in replacement of stainless steel shaft with check nut etc complete suitable for 100 to 150 HP centrifugal pump complete all as specified and directed.\nMake KSB/Kirloskar 2 Each
68 68 S&F in replacement of stainless steel shaft with check nut etc complete suitable for 30/25 HP centrifugal pump complete all as specified and directed.\nMake KSB/Kirloskar 2 Each
69 69 S&F in replacement of inter stage gunmetal/ brass bush complete suitable for 100 to 150 HPcentrifugal pump complete all as specified and directed.\nMake KSB/Kirloskar 12 Each
70 70 S&F in replacement of both end long gunmetal/ brass bush complete suitable for 100 to 150 HP centrifugal pump complete all as specified and directed.\nMake KSB/Kirloskar 6 Each
71 71 Supply only pressure plate with balancing disc suitable for 100 to 150 HP centrifugal pump complete all as specified and directed. \nMake KSB/Kirloskar 3 Each
72 72 S&F in replacement of gun metal impeller complete suitable for 100 to 150 HP centrifugal pump complete all as specified and directed.\nMake KSB/Kirloskar 6 Each
73 73 S&F in replacement of gun metal impeller complete suitable for 25/30 HP centrifugal pump complete all as specified and directed. 2 Each
74 74 Material and Labour in replacement of glands suitable for 100 to 150 HP centrifugal pump complete all as specified and directed. 10 Each Job
75 75 Material and Labour in replacement of glands suitable for 30/25HP centrifugal pump complete all as specified. 10 Each Job
76 76 Supply and Fixing in replacement pressure gauge of suitable size for 100 to 150 HP pump set complete all as specified and directed. 4 Each
77 77 Supply and Fixing in replacement pressure gauge of suitable size for 30/25/5/3 HP pump set complete all as specified and directed. 2 Each
78 78 Repair/ Replacement of fan belt of existing size and dia of main gear assy mounted on sediment tank complete all as directed . 3 Each
79 79 Repair/ Replacement of fan belt of existing size and dia of motor mounted on sediment tank complete all as directed. 3 Each
80 80 Supply and Fixing in replacement Copper Cable lugs of size 120 Sqmm for connection to copper cable complete all as specified and directed. 12 Each
81 81 Supply and Fixing in replacement Copper Cable lugs of size 150 Sqmm for connection to copper cable complete all as specified and directed. 12 Each
82 82 Supply and Fixing in replacement Cable lugs of size 70Sqmm for connection to copper cable complete all as specified and directed. 6 Each
83 83 S&F in replacement of motor connection pad assembly with existing size of upto 150 HP motor complete 2 Each
84 84 S&F in replacement of bearing housing RKB23 of make Kirloskar pump with existing size 150 HP pump complete 1 Each
85 85 S&F in replacement of Automatic phase sequence corrector with automatically correct input supply, Reverse Phase and also protection against single phasing, voltage unbalancing, low voltage high voltage with time delay motor upto 100 to 150 HP complete all as specified and directed 1 Each
86 86 Disconnection old LT Panel and Replacement, supply & fabrication of LT Panel Board CPRI approved cubical type made of 2 mm thick sheet steel indoor type with IP 43 grade of protection CRCA sheet powder coated with support of angle iron of 50 x 50 x 6 mm with double hinged front openable shutters of each feeder control unit with locking arrangement in front and back openable inspection doors PVC sleeved Aluminium bus bar of 500 Amps, 415V capacity for each phases and half neutral fixed on suitable insulator all housed in suitable bus bar chamber and cable alley and provision and fixing of LED digital Voltmeter,Ammeter with built in selector switch, CTs of suitable ratio, and pilot indication lamps connecting incoming and out going cables with suitable cable glands etc with suitable PCC foundations complete testing and commissioning complete and consisting the following :- (Drawing of Panel and connections shall be approved by Engr-in-Charge before starting the panel work) INCOMER -MCCB 3 POLE 415 V 320 A (36 KA) adjustable type -02 Nos with rotary handle Make- Havells/L&T/Legrand OUTGOING- (a) On load change over 315 Amps-02 Nos Make- Havells/L&T/Legrand (b) Digital type Ammeter 0-400A with selector switch - 2 Nos, & Digital type Voltmeter 0 - 500 V with selector switch-2No including CTs-06 Nos (c) Indicator - RYB - 3 Set 1 Each
87 87 S&F cast iron air valves with two air outlets, 150mm dia bore and fixing in cast iron water supply mains including all fixing arrangement complete all as specified and directed. 1 Each
88 88 M&L for laying common burnt bricks, sub class 'B', of size 230 x 115 x 75 mm in trenches for cable protection complete all as directed by Engr-in-charge. 800 Each
89 89 Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 M. deep for foundation or for laying of pipes etc and getting out in hard/dense soil, comlete all as specified and directed 20 Cum
90 90 Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm in hard/dense soil, complete all as specified and directed 12 Cum
91 91 Removing excavated soil to a distance exceeding 50m but not exceeding 250 m and depositing where directed at a level not exceeding 1.5 m above the starting point , complete all as specified and directed. 8 Cum
92 92 Supply and laying including taking up in trenches, under floor or fixed to walls XLPE insulated cable, screened PVC bedded, galvanised steel strip or wire armoured, electric power cable heavy duty 1100 Volts grade with stranded aluminium conductor of size 95 Sq mm 3.5 Core complete all as specified and directed. 100 RM
93 93 Supply and spreading of clean dry river sand in trenches/ transformer yard/ two pole structure yard for cable protection complete all as directed 10 CUM
Disclaimer :