| 1 | 1 | Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth and getting out in any type of soil complete all as apecified and directed. | | 91 | Cum |
|---|
| 2 | 2 | M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable complete all as specified | | 36 | Cum |
|---|
| 3 | 3 | Material and labour for sub class (B* brick, old size, brick covering laid dry, flat transversally along the length of cable on sand cushioning, with width equal to the length of the brick complete all as specified and directed. | | 3.6 | Per 1000 No |
|---|
| 4 | 4 | Returning filling in including ,spreading,levelling,watering and well ramming in layers not exc 25cm thick each complete all as specified and directed. | | 42 | Cum |
|---|
| 5 | 5 | Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed | | 49 | Cum |
|---|
| 6 | 6 | Material & Labour PCC 1:4:8 type D2 ( using 40mm graded stone aggregate) as in bottom of pit in bed concrete of poles complete all as specified. | | 1.3 | Cum |
|---|
| 7 | 7 | Material & Labour PCC 1:3:6 type C2 ( using 40mm graded stone aggregate) as in foundation of poles and stay etc complete all as specified. | | 21.6 | Cum |
|---|
| 8 | 8 | Material & Labour PCC 1:2:4 type B2 ( using 40mm graded stone aggregate) as in coping for Poles etc complete all as specified. | | 0.76 | Cum |
|---|
| 9 | 9 | M&L for replacement of existing unserviceable stay assembly complete using stay rod of 20 mm dia 180 cm long,stay wire of GI 7/4 mm stranded ,stay bow, stay clamp complete with accessories as shown in electrical plate No 01 of MES SSR Part-I (loop type insulator ,excavation and PCC shall be measured and paid separately ). | | 6 | Each |
|---|
| 10 | 10 | M&L in replacement of existing unserviceable Loop type insulator vitreous porcelan white,brown or green large size with overall dimensions 90X140mm clearance of hole 25.5.mm complete all as specified and directed. Make . Rastriya Electrical /Jai Shree /Jaipuriya/Hitkari/CJI | | 6 | Each |
|---|
| 11 | 11 | Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.3mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level, connecting to galvanised iron strip 32mm X 6mm (as earth lead strip), by means of bolt, nuts, check nuts and washer of GI and GI strip protected by provision of GI pipe light grade, 40mm bore upto test point including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25 x 25 x 3 mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 metres long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtr, all as per electrical plate No 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.\nNOTE :- Item of earthing includes the cost of 7.5 metre long galvanised iron strip 32mm X 6mm size and protection pipe of 40 mm bore galvanised iron light grade. | | 6 | Each |
|---|
| 12 | 12 | M&L for earthing complete with galvanized steel earth plate electrode 600x600x6.3mm tthick buried directly in ground(earth plate not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth wire 4mm dia by means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) including iron angle frme 40*40*6mm. and medium grade GI watering pipe 20mm dia with funnel and wire mesh and 15 mm bore GI pipe light grade proection pipe including excavation and charcoal ,common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I. | | 5 | Each \n |
|---|
| 13 | 13 | M&L for Structural steel work in replacement of existing unserviceable Cross arms bracing, supports, clamps and back plates fabricated from steel sections including nuts,bolts ,washers,welding ,bending cold or hot drilling holes for bolts in any shape or size as indicated or directed inclusive one coat of primercoat, one under coat and one finishing coat of aluminium paint complete all as specified and directed. | | 1 | Qtl |
|---|
| 14 | 14 | Material and labour for replacement of existing unserviceable GI tubing light grade 40 mm bore for passing through cables under the floor ,along the wall or along the pole complete all as specified and directed . | | 40 | RM |
|---|
| 15 | 15 | Supply & replacement of existing unserviceable Wood/ PCC pole with new Steel tublur pole complete with cast iron base plate, finial taper plug, bolt, nuts & screws as specified type 410 SP-31 ( 9 mtr long ) Note: Excavation and PCC shall be measured and paid separately . | | 15 | Each |
|---|
| 16 | 16 | M&L for replacement of old and weathered ACSR alluminium conductor of size 6/2.11 or 6/2.59 squirrel/weasel and with aluminium binding wire on poles etc traightening / tightening with mechanical devices ,complete all as specified and directed. | | 1 | Qtl |
|---|
| 17 | 17 | M&L in replacement of existing unserviceable Shackle type porcelain vitreous white, brown or green insulator working pressure 1100 Volts of 90mm dia 75mm height including galvanized mild steel strip of size 31x3mm ,size 12mm dia insulator bolt,washers and nuts complete all as apecified. | | 40 | Each |
|---|
| 18 | 18 | Supply and fixed in replacement of galvanised steel wire 4mm dia to earth wire on HT/LT poles for fabrication of cradles hexagonal/rectangular guards out of galvanised steel wire 4mm dia etc complete all as specified and directed. | | 0.2 | Qtl |
|---|
| 19 | 19 | Supply & lay in replacement of existing unserviceable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volt grade of cross sectional area 95 Sqmm 3.5 Core all as specified & directed by Engr-in-Charge. | | 150 | RM |
|---|
| 20 | 20 | Supply & lay in replacement of existing unserviceable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volt grade of cross sectional area 70 Sqmm 3.5 Core all as specified & directed by Engr-in-Charge. | | 160 | RM |
|---|
| 21 | 21 | Supply & lay in replacement of existing unserviceable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volt grade of cross sectional area 50 Sqmm 3.5 Core all as specified & directed by Engr-in-Charge. | | 120 | RM |
|---|
| 22 | 22 | Supply & laying replacement of existing unserviceable XLPE insulated, armoured heavy dutyelectric cable with aluminium conductor, 1100 volt grade of cross sectional area 25 Sqmm 3.5 Core all as specified & directed by Engr-in-Charge. | | 800 | RM |
|---|
| 23 | 23 | Supply & laying replacement of existing unserviceable XLPE insulated, armoured heavy dutyelectric cable with aluminium conductor, 1100 volt grade of cross sectional area 16 Sqmm 2 Core all as specified & directed by Engr-in-Charge. | | 120 | RM |
|---|
| 24 | 24 | Supply and fixing 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, one twin core cable flat or circular stranded conductor size of 16 Sqmm, 2 core complete all as specified. | | 200 | RM |
|---|
| 25 | 25 | Supply and fixing 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, one twin core cable flat or circular stranded conductor size of 10 Sqmm, 2 core complete all as specified. | | 500 | RM |
|---|
| 26 | 26 | Supply Install commissioning and testing of Fabrication of LToutdoor Cubical panel Board pre-wired size 1.2x1.2x.45mtr by CPRI approved fabricator of suitable size made of 3.15mm thick CRCA sheet mounted on frame of mild steel angle iron 40x40x6mm, duly supported with mild steel angle iron on plain cement concrete foundation (As per manufacturers instuctions) having height 60cms from ground level & 30 cms below ground level. LT panel shall be totally enclosed weather proof and vermin proof with front and rear opening arrangements (double door)) with IP-54 protection as per IS-8623 duly powder coated for 433 volts, 3 phase, 4 wire with 630 Amps aluminium bus bar, p including cable glands, epoxy insulation and nuts, bolts, washers etc.. complete providing suitable of size copper cable/strip as required or as per manufacturer\"s recommendations with following accessories:-\nIncoming:- \n(a) MCCB 4 pole 250 Amp of breaking capacity 50KA at 415 V 50 Hz , AC supply -01 Nos \nb) Digitial volt meter 0 to 500 volts, with selecter switch – 01 No.\n(c ) Digital Ammeter 0-500 Amps with selector switch- 01Nos \n(d) Current Transformer rating 100/5, 5VA - Set of three\n(e) Indicator lamp (LED type) – 01 Sets (set of three R,Y,B)\n\nOut going \n(a) MCCB 4 pole of breaking capacity 25 KA at 415 V 50 Hz , AC supply 100A -04 Nos | | 4 | Each job |
|---|
| 27 | 27 | Supply & replacement of existing unserviceable busbar box , installation, testing and commissioning of factory fabricated prewired bus bar, cubical type of appropriate size 60cm x 45cm x 18cm out door dust vermin proof, made out of 40x40x6mm angle iron frame/legs and 3.15 mm thick CRCA sheet with openable shutters on both sides (front & rear), powder coated externally and internally, having locking arangement mounted on four legs 90cm high (30 cm below ground level and 60 cm above ground level),Panel embedded in PCC (1:2:4 ) type B2 of suitable size with clear working space all around the bus bar. LT panel shall be totally enclosed weather proof and vermin proof with front and rear opening arrangements (double door)) with IP-54 protection as per IS-8623 duly powder coated for 433 volts, 3 phase, 4 wire with 200 Amps aluminium bus bar, including cable glands, epoxy insulation and nuts, bolts, washers etc.. complete providing suitable of size copper cable/strip as required or as per manufacturer\"s recommendations complete all as specified & directed by the Engr-in-Charge to accommodate the following accessories :- \n(a) MCCB 4 Pole 160 A 25KA - 1 No (Make:- Hager) Cat part No.HDA161Z with X160 frame MCCB fixed overload, fixed short circuitbreaking capacity \n(b) Copper bus bar 200 A for three phase and neutral duly insulated with sleeves of different colour RYB .\n(Note : (i) Incoming and outgoing cable shall be fixed with appropriate size of copper thimble. \n(ii) Apron shall be provided at bottom for protection of cable to avoid entry of vermins, reptiles.\n(iii) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands.\n(ii) Apron shall be provided at bottom for protection of cable to avoid entry of vermins, reptiles.\n(iii) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands.\n\n | | 2 | Each Job |
|---|
| 28 | 28 | Supply & replacement of existing unserviceable busbar box , installation, testing and commissioning of factory fabricated prewired bus bar, cubical type of appropriate size 60cm x 45cm x 18cm out door dust vermin proof, made out of 40x40x6mm angle iron frame/legs and 3.15 mm thick CRCA sheet with openable shutters on both sides (front & rear), powder coated externally and internally, having locking arangement mounted on four legs 90cm high (30 cm below ground level and 60 cm above ground level),Panel embedded in PCC (1:2:4 ) type B2 of suitable size with clear working space all around the bus bar. LT panel shall be totally enclosed weather proof and vermin proof with front and rear opening arrangements (double door)) with IP-54 protection as per IS-8623 duly powder coated for 433 volts, 3 phase, 4 wire with 200 Amps aluminium bus bar, including cable glands, epoxy insulation and nuts, bolts, washers etc.. complete providing suitable of size copper cable/strip as required or as per manufacturer\"s recommendations complete all as specified & directed by the Engr-in-Charge to accommodate the following accessories :- \n(a) Aluminium bus bar 200 A for three phase and neutral duly insulated with sleeves of different colour RYB . \n(Note : (i) Incoming and outgoing cable shall be fixed with appropriate size of copper thimble. \n(ii) Apron shall be provided at bottom for protection of cable to avoid entry of vermins, reptiles.\n(iii) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands.\n(ii) Apron shall be provided at bottom for protection of cable to avoid entry of vermins, reptiles.\n(iii) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands.\n | | 4 | Each Job |
|---|
| 29 | 29 | Painting to existing steel tubular poles 09 mtr long including cross arms, clamps etc. with two coats of aluminum paint on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with white and black paint alternatively on external surface above PCC copping including preparation of old painted surfaces by scraping complete. | | 100 | Each |
|---|
| 30 | 30 | Cutting /trimming tree branches along the over head HT/LT lines up to 2.0 mtr from electric line on both sides of the span and disposing of the cut tree /branches at places as dirested by Engr-in-charge. | | 100 | Each Span |
|---|
| 31 | 31 | Numbering of poles with synthetic enameled paint complete all as specified and directed. (Note:_-the numbering shall be hand written only stencils embossing shall not be allowed ,and size of letter shall be 50x10 mm (height x width ). | | 50 | Each |
|---|
| 32 | 32 | M&L for replacement of UG LT PVC insulated armoured heavy duty cable end terminal joints ( heat shrinkable) of along Pole etc suitable for aluminium conductor cable and testing after jointing of size 50-95 sqmm | | 2 | Each |
|---|
| 33 | 33 | M & L for replacement of LT cable route indicator reading \"MES LT UG 1100 V cable\" and route of cable with arrow, made out of CI in square shape of size 200mm x 200mm x 10mm with 150mm leg, fixed in PCC pre-cast block of 250mm x 250mm x 1000mm | | 50 | Each |
|---|
| 34 | 34 | Labour only for removal of existing broken PCC pole in the enrooted the existing LT/HT line where span is more than 50 mtr and will be contractor own responsibility to take of necessary precautions to avoid any accident. Broken pole shall be buried in situ after making necessary trench not exceeding 30 Cm depth and width at no extra cost. | | 10 | Each |
|---|
| 35 | 35 | Supply and fix in replacement of 25 watt LED new generation post-top energy saving, environmental friendly long life aesthetically designed with symmetrical light distribution,spun aluminium landscape luminaire with high power LEDs as light source including necessary electric connection along with 40mm dia GI pipe 2.5 mtr long complete all as specified and directed by Engr-in-Charge . Make: Havells. Model. CORAL (OPAL) IP65, Cat Part No :CORALPT25WLED757PSYMTOPC or equivalent in crompton/wipro | | 20 | Each |
|---|
| 36 | 36 | Supply and fix in replacement of existing unserviceable driver for LED fitting of capacity 45 Watt all as per sample and as directed by Engr-in-Charge. | | 40 | Each |
|---|
| 37 | 37 | Supply and fix in replacement of existing unserviceable driver for LED fitting of capacity 72 Watt all as per sample and as directed by Engr-in-Charge. | | 30 | Each |
|---|
| 38 | 38 | Supply & replacement of existing unserviceable SVL/HPSV fitting with new new generation energy saving and environmental friendly long life LED street light 30watt made up to pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening separate driver compartment with IP66 protection and impact resistance of IK07 with 10KV built in surge protection device including GI bracket of 40 mm bore 1.5 mtr long bent to any shape required as per site and making neccessry connection with 2.5 sqmm copper wire from fitting to pole box all as directed by Engr-in- Charge. make : Havells/ Suriya/wipro/Bajaj | | 25 | Each |
|---|
| 39 | 39 | M & L for cutting of existing road/ floor/ plinth/drain for taking out/laying of UG cable through GI pipe including necessary earth work excavation and making good to match with existing surface complete all as specified with PCC 1:3:6 type C1 by (using 20mm graded stone aggregate) complete all as specified. | | 30 | RM |
|---|
| 40 | 40 | S&F in replacement of existing unserviceable MCCB any size/capacity with MCCB 4 pole 250 Amps 50 KA, MCCBs microprocessor release,overload adjustable = 0.4 to 1 x Inshort circuit adjustable 2.5 to 10 x Ir (250-400A) 2.5 to 8 x Ir (630A) time delay 0.1 - 0.2 sec. & suitable thimbles/extended terminal with nuts,bolts and washers etc including minor required additional/alternation for fixing and connecting up of MCCB all as directed by Engr-in-Charge.Make : Hager Cat Part No HNC251H or equivalent in Schnider/Indoasian. Note- Rate of extended terminal deemed to be included in item of rate. | | 2 | Each |
|---|
| 41 | 41 | S&F in replacement of existing unserviceable MCCB any size & capacity with MCCB 4 pole 200 Amps,Icu 40 KA MCCBs thermal magnetic release,Over load adjustable 0.63-0.8-1 x Inshort circuit adjustable6-8-10-13 x In (100-200A)5-7-9-11 x In (250A) & suitable thimbles/extended terminal with nuts,bolts and washers etc including minor required additional/alternation for fixing and connecting up of MCCB all as directed by Engr-in-Charge.Make : Hager Cat Part No HNB201U or equivalent in Schnider/Indoasian. Note- Rate of extended terminal deemed to be included in item of rate. | | 2 | Each |
|---|
| 42 | 42 | S&F in replacement of existing unserviceable MCCB any size & capacity with MCCB 4 pole 160 Amps,Icu 40 KA MCCBs thermal magnetic release,Over load adjustable 0.63-0.8-1 x Inshort circuit adjustable6-8-10-13 x In (100-200A)5-7-9-11 x In (250A) & suitable thimbles/extended terminal with nuts,bolts and washers etc including minor required additional/alternation for fixing and connecting up of MCCB all as directed by Engr-in-Charge.Make : Hager Cat Part No HNB161U or equivalent in Schnider/Indoasian. Note- Rate of extended terminal deemed to be included in item of rate. | | 1 | Each |
|---|
| 43 | 43 | S&F in replacement of existing unserviceable MCCB any size & capacity with MCCB 4 pole 100 Amps,Icu 40 KA MCCBs thermal magnetic release,Over load adjustable 0.63-0.8-1 x Inshort circuit adjustable6-8-10-13 x In (100-200A)5-7-9-11 x In (250A) & suitable thimbles/extended terminal with nuts,bolts and washers etc including minor required additional/alternation for fixing and connecting up of MCCB all as directed by Engr-in-Charge.Make : Hager Cat Part No HNB101U or equivalent in Schnider/Indoasian. Note- Rate of extended terminal deemed to be included in item of rate. | | 1 | Each |
|---|
| 44 | 44 | S&F in replacement of existing unserviceable MCCB any size & capacity with MCCB 4 pole 63 Amps,Icu 40 KA MCCBs thermal magnetic release,X160 frame MCCB overload adjustable 0.63-0.8-1 x Inshort circuit fixed breaking Capacity & suitable thimbles/extended terminal with nuts,bolts and washers etc including minor required additional/alternation for fixing and connecting up of MCCB all as directed by Engr-in-Charge.Make : Hager Cat Part No HNA064U or equivalent in Schnider/Indoasian. Note- Rate of extended terminal deemed to be included in item of rate. | | 1 | Each |
|---|