Hll Lifecare Limited-HLL has published Civil And Electrical Works For Setting Up Of Medical Oxygen Plant For Converting Hospital To Covid Treatment Centre At Dh Kollam. Submission Date for this Tender is 02-05-2020. Earth Moving Machinery Tenders in District Hospital Kollam Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

24207991
Civil And Electrical Works For Setting Up Of Medical Oxygen Plant For Converting Hospital To Covid Treatment Centre At Dh Kollam
Open Tender
Indian
Kerala
District Hospital Kollam
02-05-2020

Tender Details

Civil And Electrical Works For Setting Up Of Medical Oxygen Plant For Converting Hospital To Covid Treatment Centre At Dh Kollam , Civil Work , Demolishing And Dismantling Works , Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge . In Cement Mortar , Dismantling Aluminium / Gypsum Partitions , Doors , Windows , Fixed Glazing And False Ceiling Including Disposal Of Unserviceable Surplus Material And Stacking Of Serviceable Material With In 50 Metres Lead As Directed By Engineer - In-Charge , Taking Out Doors , Windows And Clerestory Window Shutters ( Steel Or Wood ) Including Stacking Within 50 Metres Lead:Of Area Beyond 3 Sq . Metres , Dismantling Of Flushing Cistern Of All Types ( C . I . / Pvc / Vitrous China ) Including Stacking Of Useful Materials Near The Site And Disposal Of Unserviceable Materials Within 50 Metres Lead , Earth Work , Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1 . 5 M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms , Lift Up To 1 . 5 M , Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed , Within A Lead Of 50 M . All Kinds Of Soil , Filling Available Excavated Earth ( Excluding Rock ) In Trenches , Plinth , Sides Of Foundation Etc . In Layers Not Exceeding 20 Cm In Depth , Consolidating Each Deposited Layer By Ramming And Watering , Lead Up To 50 M And Lift Up To 1 . 5 M . , Clearing Jungle Including Uprooting Of Rank Vegetation , Grass , Brush Wood , Trees And Saplings Of Girth Up To 30 Cm Measured At A Height Of 1 M Above Ground Level And Removal Of Rubbish Up To A Distance Of 50 M Outside The Periphery Of The Area Cleared , Cement Concrete , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:2:4 ( Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:4:8 ( 1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Nominal Size ) , Masonry Work , Random Rubble Masonry With Hard Stone In Foundation And Plinth Including Levelling Up With Cement Concrete 1:6:12 ( 1 Cement : 6 Coarse Sand : 12 Graded Stone Aggregate 20 Mm Nominal Size ) Up To Plinth Level With:Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) , Brick Work With Common Burnt Clay F . P . S . ( Non Modular ) Bricks Of Class Designation 7 . 5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In:Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Rcc Work , Reinforced Cement Concrete Work In Beams , Suspended Floors , Roofs , Having Slope Up To 150 Landings , Balconies , Shelves , Chajjas , Lintels , Bands , Plain Window Sills , Staircases And Spiral Stair Cases Up To Floor Five Level Excluding The Cost Of Centering , Shuttering , Finishing And Reinforcement , With1:1 . 5:3 ( 1 Cement : 1 . 5 Coarse Sand ( Zone Iii ) : 3 Graded Stone Aggregate 20 Mm Nominal Size ) . , Centering And Shuttering Including Strutting , Etc . And Removal Of Form For:Lintels , Beams , Plinth Beams , Girders Bressumers And Cantilevers , Steel Reinforcement For R . C . C Work Including Straightening , Cutting , Bending , Placing In Position And Binding All Complete Upto Plinth Levelthermo - Mechanically Treated Bars Of Grade Fe-500D Or More , Plastering , 12 Mm Cement Plaster Finished With A Floating Coat Of Neat Cement Of Mix:1:4 ( 1 Cement : 4 Fine Sand ) , 15 Mm Cement Plaster On Rough Side Of Single Or Half Brick Wall Of Mix:1:4 ( 1 Cement : 4 Coarse Sand ) , Painting , Distempering With Dry Distemper Of Approved Brand And Manufacture ( Two Or More Coats ) Of Required Shade On New Work , Over And Including Water Thinnable Priming Coat To Give An Even Shade: , Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade:New Work ( Two Or More Coat Applied @ 1 . 67 Ltr / 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2 . 20 Kg / 10 Sqm ) , Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work , Painting On G . S . Sheet With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Given An Even Shade:New Work ( Two Or More Coats ) Including Coat Of Approved Steel Primer But Excluding A Coat Of Mordant Solution . , Steel Work , Steel Work In Built Up G I Tubular ( Round , Square Or Rectangular Hollow Tubes Etc . ) Trusses Etc . , Including Cutting , Hoisting , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer , Including Welding And Bolted With Special Shaped Washers Etc . Complete , Providing And Fixing 1 Mm Thick M . S . Sheet Door With Frame Of 40X40x6 Mm Angle Iron And 3 Mm M . S . Gusset Plates At The Junctions And Corners , All Necessary Fittings Complete , Including Applying A Priming Coat Of Approved Steel Primer . Using M . S . Angels 40X40x6 Mm For Diagonal Braces , Providing At All Heights , Levels And Locations 0 . 45 Mm Thick Galvalume Sheet Of Alloy 31500 / 31000 / 40800 , Conforming To Is 1254 , Is 737 , Is 2676 . The Sheet Shall Be Fixed Using Self Drilling / Self Tapping Ss Screws Of Size 5 . 5X65 Mm With Epdm Seal Complete Upto Required Pitch In Horizontal , Vertical Or Curved Surfaces I / C Cutting To Size And Shape Where Required As Per The Direction Of Engineer-In-Charge . The Rate Shall Be Inclusive Of All Screws , Seal , Ridge , Labour , Scaffolding , Machinery For Fixing And Approved Sealant Where Required Etc . But Excluding The Cost Of Purlins , Rafters And Trusses , Providing And Fixing Hard Drawn Steel Wire Fabric 75X25 Mm Mesh Of Weight Not Less Than 7 . 75 Kg Per Sqm To Window Frames Etc . Including 62X19 Mm Beading Of Second Class Teak Wood And Priming Coat With Approved Steel Primer All Complete . , Providing And Fixing Fiber Glass Reinforced Plastic ( Frp ) Door Frames Of Cross- Section 90 Mm X 45 Mm Having Single Rebate Of 32 Mm X 15 Mm To Receive Shutter Of 30 Mm Thickness . The Laminated Shall Be Moulded With Fire Resistant Grade Unsaturated Polyester Resin And Chopped Mat . Door Frame Laminate Shall Be 2 Mm Thick And Shall Be Filled With Suitable Wooden Block In All The Three Legs . The Frame Shall Be Covered With Fiber Glass From All Sides . M . S . Stay Shall Be Provided At The Bottom To Steady The Frame . , Providing And Fixing To Existing Door Frames . 30 Mm Thick Fiberglass Reinforced Plastic ( F . R . P ) Flush Door Shutter In Different Plain And Wood Finish Made With Fire Retardant Grade Unsaturated Polyester Resin , Moulded To 3 Mm Thick Frp Laminate All Around , With Suitable Wooden Blocks Inside At Required Places For Fixing Of Fittings And Polyurethane Foam ( Puf ) / Polystyrene Foam To Be Used All Filler Material Throughout The Hollow Panel , Casted Monoolithically With Testing Parameters Of F . R . P . Laminate Conforming To Table - 3 Of Is : 14856 , Complete As Per Direction Of Engineer-In-Charge . , Providing And Fixing Stainless Steel ( Grade 304 ) Railing Made Of Hollow Tubes , Channels , Plates Etc . , Including Welding , Grinding , Buffing , Polishing And Making Curvature ( Wherever Required ) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete , I / C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc . , Of Required Size On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge , ( For Payment Purpose Only Weight Of Stainless Steel Membe

Key Value

Document Fees
INR 2800 /-
EMD
INR 20000.0 /-
Tender Value
INR 9.64 Lakhs /-

BOQ Items

Name of Work: Civil and Electrical works for Setting Up of Medical Gas plant with Manifold Room for Converting Hospital to Covid Treatment Centre at District Hospital Kollam
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Civil Work
2 1.01 Demolishing and Dismantling Works
3 1.11 Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar 3.112 CUM
4 1.12 Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge 42.39 SQM
5 1.13 Taking out doors, windows and clerestory window shutters (steel or wood ) including stacking within 50 metres lead:Of area beyond 3 sq. metres 2 EACH
6 1.14 Dismantling of flushing cistern of all types (C.I. / PVC/ Vitrous China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead 2 EACH
7 2 Earth Work
8 2.01 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 14.21 CUM
9 2.02 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 5.357 CUM
10 2.03 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared 67 SQM
11 3 Cement Concrete
12 3.01 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 1.44 CUM
13 3.02 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 1.89 CUM
14 4 Masonry Work
15 4.01 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) 6.92 CUM
16 4.02 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in:Cement mortar 1:4 ( 1 cement : 4 coarse sand) 12.509 CUM
17 5 RCC Work
18 5.01 Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size). 1.723 CUM
19 5.02 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 5.475 SQM
20 5.03 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 287.572 KG
21 6 Plastering
22 6.01 12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1 cement : 4 fine sand) 118.887 SQM
23 6.02 15 mm cement plaster on rough side of single or half brick wall of mix:1:4 ( 1 Cement : 4 coarse sand) 14.4 SQM
24 7 Painting
25 7.01 Distempering with dry distemper of approved brand and manufacture (two or more coats) of required shade on new work, over and including water thinnable priming coat to give an even shade: 294.372 SQM
26 7.02 Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 22.364 SQM
27 7.03 Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work 272.008 SQM
28 7.04 Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to given an even shade:New work (two or more coats) including coat of approved steel primer but excluding a coat of mordant solution. 53.078 SQM
29 8 Steel Work
30 8.01 Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete 623.94 KG
31 8.02 Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces 12.6 SQM
32 8.03 Providing at all heights, levels and locations 0.45 mm thick Galvalume sheet of Alloy 31500/31000/40800, conforming to IS 1254, IS 737, IS 2676. The sheet shall be fixed using self drilling/self tapping SS screws of size 5.5x65 mm with EPDM seal complete upto required pitch in horizontal, vertical or curved surfaces i/c cutting to size and shape where required as per the direction of Engineer-in-Charge. The rate shall be inclusive of all screws, seal, ridge, labour, scaffolding, machinery for fixing and approved sealant where required etc. but excluding the cost of purlins, rafters and trusses 23.18 SQM
33 8.04 Providing and fixing hard drawn steel wire fabric 75x25 mm mesh of weight not less than 7.75 Kg per sqm to window frames etc. including 62x19 mm beading of second class teak wood and priming coat with approved steel primer all complete. 6.795 SQM
34 8.05 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 12.8 M
35 8.06 Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer-in-charge. 4.621 SQM
36 8.07 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) 106.5 KG
37 8.08 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid 2 EACH
38 8.09 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionAnodised aluminium (anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15) 5.778 KG
39 8.1 For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) 10.651 KG
40 8.11 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides 1.32 SQM
41 8.12 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness 1.32 SQM
42 8.13 nullUpto 5 mm depth and 5 mm width 8.4 M
43 8.14 Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in-Charge.Anodized (AC 15 ) aluminium 2 NO
44 8.15 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 1 NO
45 8.16 Providing and fixing PTMT Tower Bolts with 12 mm one piece rod inside and necessary screws etc., complete.202x42x18 mm weighing not less than 78 gms 2 NO
46 9 ELECTRICAL WORKS - POINT WIRING
47 9.01 Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point 14 Point
48 9.02 Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Independent plug - Short point 16 EACH
49 10 SUB MAINS / CIRCUIT MAINS
50 10.01 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire 120 M
51 10.02 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire 20 M
52 10.03 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp 54.2 M
53 10.04 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 140 M
54 10.05 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.16 sq mm 26 EACH
55 10.06 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.35 sq mm 8 EACH
56 11 POWER CIRCUITRY and EARTHING
57 11.01 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) 1 EACH
58 11.02 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 5 EACH
59 11.03 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 2 EACH
60 11.04 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 2 EACH
61 11.05 Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL 1 NO
62 11.06 Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.5 KVAr, 3 phase, 440 V, delta connected, standard duty Metalised Poly Propylene Capacitor, Box Type, suitable for direct connection to motors. 4 EACH
63 11.07 S & F Motor starters of the following ratingsSemiautomatic star delta starter for 5 to 7.5HP motor 4 EACH
64 11.08 S & F Motor starters accessories of the followingPush button station for starters 2 EACH
65 11.09 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 2 Set
66 11.1 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 77.8 M
67 11.11 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing asrequired. 72 M
68 12 SITC FITTINGS
69 12.01 20W LED TUBE TYPE FIXTURE<br>SITC OF Modular type 20W LED tube type fixture directly on to wall including drilling and fixing, making necessary connections and make as approved by engineer in Charge or Electrical Engineer. 14 Each
70 12.02 EXHAUST FAN,SHUTTER TYPE <br>Supply and installation EXHAUST FAN,SHUTTER TYPE white colour, 9" OR 10" star rated as per BEE complete with its all accessories(Make Havells/bajaj/usha/Vguard) 9 Each
71 12.03 Charges for cutting holes suitable for accommodating exhaust fans above 305mm sweep and up to 450mm sweep including plastering colour washing etc. as required. 9 Each
72 12.04 Conveyance, installation , testing and commissioning of exhaust fans of size up to 450mm in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan. 9 Each
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail