Power Boards / Undertakings / PSU Closing in 0 days TDR #24206411

908/Epd-Ii/Btps/Anp/2020-21 Supply , Installation And Commissioning Of Magnetic Flow Meters For Atp , Anpara

Issued by Boards / Undertakings / PSU · ANPARA SONEBHADRA, Uttar Pradesh
Tender Value
1.63 Crore
Estimated cost
Bid Submission
14 May 2020
0 days left
EMD
3 Lakhs
Bank guarantee accepted
Document Fee
4720
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
ANPARA SONEBHADRA → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

908/Epd-Ii/Btps/Anp/2020-21 Supply , Installation And Commissioning Of Magnetic Flow Meters For Atp , Anpara , Electromagnetic Flow Meter For Lp Pumps ( 04 Nos . Pumps For Each Unit ) Common Header Discharge Line For Unit 4 &5 Btps . Type Of Flow Sensor: Full Bore Type Medium: Clean Raw Water Fluid Velocity: 2-3 M/S Material Of Pipe= Ms Line Line Size: 450 Mm Nb Operating Pressure: 10 Kg/Cm2 Maximum Pressure: 20 Kg/Cm2 Maximum Flowrate: 1260 M3/Hr , Electromagnetic Flow Meter For Hp Pumps ( 04 Nos . Pumps For Each Unit ) Common Header Discharge Line For Unit 4 &5 Btps . Type Of Flow Sensor: Full Bore Type Medium: Clean Raw Water Fluid Velocity: 2-3 M/S Material Of Pipe= Ms Line Line Size:400 Mm Nb Operating Pressure: 14 Kg/Cm2 Maximum Pressure: 20 Kg/Cm2 Maximum Flowrate: 800 M3/Hr , Electromagnetic Flow Meter For Lp Pumps ( 05 Nos . For All Three Units Of Atps ) Common Header Discharge Line For Unit 1 , 2 &3 Atps . Type Of Flow Sensor: Full Bore Type Medium: Clean Raw Water Fluid Velocity: 2-3 M/S Material Of Pipe= Ms Line Working Principle: Faradey Laws Of Electromagnetic Induction Line Size:500 Mm Nb Operating Pressure: 6 . 5 Kg/Cm2 Maximum Pressure: 12 Kg/Cm2 Wire Housing: Welded Sheet Steel Maximum Flow Rate: 1000 M3/Hr , Electromagnetic Flow Meter For Hp Pumps ( 05 Nos . Pumps For All Three Units Of Atps ) Common Header Discharge Line For Unit 1 , 2 & 3 Atps . Type Of Flow Sensor: Full Bore Type Medium: Clean Raw Water Fluid Velocity: 2-3 M/S Material Of Pipe= Ms Line Line Size: 450 Mm Nb Operating Pressure: 10 Kg/Cm2 Maximum Pressure: 20 Kg/Cm2 Maximum Flowrate:1000 M3/Hr , Electromagnetic Flow Meter For Awrs Pumps For Dtps Discharge Line For Unit 6&7 . Type Of Flow Sensor: Full Bore Type Medium: Awrs Pond Water Fluid Velocity: 2-3 M/S Material Of Pipe= Ms Line Working Principle: Faradey Laws Of Electromagnetic Induction Line Size: 800 Mm Nb Operating Pressure: 12-15 Kg/Cm2 Maximum Design Pressure: 20 Kg/Cm2 Wire Housing: Welded Sheet Steel Maximum Flowrate: 4000 M3/Hr Pressure Of Awrs Water:<16 Kg/Cm2 , Electromagnetic Flow Meter For Awrs Pumps For Atps & Btps Discharge Line For Unit 1 To 5 . Type Of Flow Sensor: Full Bore Type Medium: Awrs Pond Water Fluid Velocity: 2-3 M/S Material Of Pipe= Ms Line Working Principle: Faradey Laws Of Electromagnetic Induction Line Size: 500 Mm Nb Operating Pressure: 12-15 Kg/Cm2 Maximum Design Pressure: 20 Kg/Cm2 Wire Housing: Welded Sheet Steel Maximum Flowrate: 3000 M3/Hr Pressure Of Awrs Water:<16 Kg/Cm2 , Clamp On Ultrasonic Flow Meter For Balp Pumps ( 03 Nos . Balp For All Two Units Of Dtps ) Common Header Discharge Line For Unit 6&7 Dtps . Type Of Flow Sensor: Clamp On Type Medium: Clean Raw Water Fluid Velocity: 2-3 M/S Material Of Pipe= Ms Line Operating Pressure: 2 . 5 Kg/Cm2 Maximum Pressure: 5 . 0 Kg/Cm2 Maximum Flowrate:1210 M3/Hr . Line Size: 400 Mm Nb , Clamp On Ultrasonic Flow Meter For Balp Pumps ( 03 Nos . Balp For All Two Units Of Dtps ) Common Header Discharge Line For Unit 6&7 Dtps . Type Of Flow Sensor: Clamp On Type Medium: Clean Raw Water Fluid Velocity: 2-3 M/S Material Of Pipe= Ms Line Operating Pressure: 2 . 5 Kg/Cm2 Maximum Pressure: 5 . 0 Kg/Cm2 Maximum Flowrate:1210 M3/Hr . Line Size: 300 Mm Nb , Clamp On Ultrasonic Flow Meter For Bahp Pumps ( 02 Nos . For All Two Units Of Dtps ) Common Header Discharge Line For Unit 6&7 Dtps . Type Of Flow Sensor: Full Bore Type Medium: Clean Raw Water Fluid Velocity: 2-3 M/S Material Of Pipe= Ms Line Operating Pressure: 9 . 0 Kg/Cm2 Maximum Pressure: 15 . 0 Kg/Cm2 Maximum Flowrate: 1050 M3/Hr . Line Size: 300 Mm Nb , Clamp On Ultrasonic Flow Meter For Flush Pumps ( 01 Nos . For All Two Units Of Dtps ) Header Discharge Line For Unit 6 &7 Dtps . Type Of Flow Sensor: Full Bore Type Medium: Clean Raw Water Fluid Velocity: 2-3 M/S Material Of Pipe= Ms Line Operating Pressure: 2 Kg/Cm2 Maximum Pressure: 5 Kg/Cm2 Maximum Flowrate:965 M3/Hr Line Size: 400 Mm Nb , Clamp On Ultrasonic Flow Meter For Fahp Pumps ( 03 Nos . For All Two Units Of Dtps ) Common Header Discharge Line For Unit 6 &7 Dtps . Type Of Flow Sensor: Full Bore Type Medium: Clean Raw Water Fluid Velocity: 2-3 M/S Material Of Pipe= Ms Line Operating Pressure: 7 . 5 Kg/Cm2 Maximum Pressure: 15 Kg/Cm2 Maximum Flowrate: 1050 M3/Hr . Line Size: 350 Mm Nb , Clamp On Ultrasonic Flow Meter For Fahp Pumps ( 03 Nos . For All Two Units Of Dtps ) Common Header Discharge Line For Unit 6 &7 Dtps . Type Of Flow Sensor: Full Bore Type Medium: Clean Raw Water Fluid Velocity: 2-3 M/S Material Of Pipe= Ms Line Operating Pressure: 7 . 5 Kg/Cm2 Maximum Pressure: 15 Kg/Cm2

BOQ

Supply, Installation and Commissioning of Magnetic Flow Meters for ATP Anpara
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Electromagnetic Flow meter for LP Pumps \n (04 nos. Pumps for each unit) common header \nDischarge Line for unit 4 &5 BTPS. \n Type of Flow sensor: Full Bore Type \n Medium: Clean Raw water \n Fluid velocity: 2-3 m/s \n material of Pipe= MS Line Line Size: 450 mm NB \n Operating Pressure: 10 Kg/cm2 \n Maximum Pressure: 20 kg/cm2 \n Maximum flowrate: 1260 m3/hr\nitem12Nos.
22Electromagnetic Flow meter for HP Pumps \n ( 04 nos. Pumps for each unit) common header \nDischarge Line for unit 4 &5 BTPS. \nType of Flow sensor: Full Bore Type \n Medium: Clean Raw water \n Fluid velocity: 2-3 m/s \n material of Pipe= MS Line Line Size:400 mm NB \n Operating Pressure: 14 Kg/cm2 \n Maximum Pressure: 20 kg/cm2 \n Maximum flowrate: 800 m3/hr\nitem22Nos.
33Electromagnetic Flow meter for LP Pumps \n (05 Nos. for all three units of ATPS) \ncommon header Discharge Line for unit 1,2 &3 ATPS. Type of Flow sensor: Full Bore Type \n Medium: Clean Raw water \n Fluid velocity: 2-3 m/s \n material of Pipe= MS Line \n Working Principle: Faradey Law's of Electromagnetic Induction \n Line Size:500 mm NB \nOperating Pressure: 6.5 Kg/cm2 \n Maximum Pressure: 12 kg/cm2 \n Wire housing: welded sheet steel \n Maximum flow rate: 1000 m3/hr\nitem31Nos.
44Electromagnetic Flow meter for HP Pumps \n (05 nos. Pumps for all three units of ATPS) common header Discharge Line for unit 1, 2 & 3 ATPS. Type of Flow sensor: Full Bore Type \n Medium: Clean Raw water \n Fluid velocity: 2-3 m/s \n material of Pipe= MS Line \n Line Size: 450 mm NB \n Operating Pressure: 10 Kg/cm2 \n Maximum Pressure: 20 kg/cm2 Maximum flowrate:1000 m3/hr\nitem41Nos.
55Electromagnetic Flow meter for AWRS Pumps for DTPS Discharge Line for unit 6&7. \n Type of Flow sensor: Full Bore Type \n Medium: AWRS Pond water \n Fluid velocity: 2-3 m/s \n Material of Pipe= MS Line \n Working Principle: Faradey Law's of Electromagnetic Induction Line Size: 800 mm NB \n Operating Pressure: 12-15 Kg/cm2 \n Maximum Design Pressure: 20 kg/cm2 \n Wire housing: welded sheet steel \n Maximum flowrate: 4000 m3/hr \n Pressure of AWRS water:<16 kg/cm2\nitem51Nos.
66Electromagnetic Flow meter for AWRS Pumps for ATPS & BTPS Discharge Line for unit 1 to 5. Type of Flow sensor: Full Bore Type \n Medium: AWRS Pond water \n Fluid velocity: 2-3 m/s \n Material of Pipe= MS Line \n Working Principle: Faradey Law's of Electromagnetic Induction Line Size: 500 mm NB \n Operating Pressure: 12-15 Kg/cm2 \n Maximum Design Pressure: 20 kg/cm2 \n Wire housing: welded sheet steel \n Maximum flowrate: 3000 m3/hr \n Pressure of AWRS water:<16 kg/cm2\nitem62Nos.
77Clamp ON Ultrasonic Flow meter for BALP Pumps \n(03 nos. BALP for all two units of DTPS) common header Discharge Line for unit 6&7 DTPS. Type of Flow sensor: Clamp On Type \n Medium: Clean Raw water \n Fluid velocity: 2-3 m/s \n material of Pipe= MS Line Operating Pressure: 2.5 Kg/cm2 \nMaximum Pressure: 5.0 kg/cm2 \nMaximum flowrate:1210 m3/hr.\nLine Size: 400 mm NB\nitem71Nos.
88Clamp ON Ultrasonic Flow meter for BALP Pumps \n(03 nos. BALP for all two units of DTPS) common header Discharge Line for unit 6&7 DTPS. Type of Flow sensor: Clamp On Type \n Medium: Clean Raw water \n Fluid velocity: 2-3 m/s \n material of Pipe= MS Line Operating Pressure: 2.5 Kg/cm2 \nMaximum Pressure: 5.0 kg/cm2 \nMaximum flowrate:1210 m3/hr.\nLine Size: 300 mm NB\nitem81Nos.
99Clamp ON Ultrasonic Flow meter for BAHP Pumps \n(02 nos. for all two units of DTPS) common header Discharge Line for unit 6&7 DTPS. Type of Flow sensor: Full Bore type\n Medium: Clean Raw water \n Fluid velocity: 2-3 m/s \n material of Pipe= MS Line Operating Pressure: 9.0 Kg/cm2 \nMaximum Pressure: 15.0 kg/cm2 \nMaximum flowrate: 1050 m3/hr.\nLine Size: 300 mm NB\nitem91Nos.
1010Clamp ON Ultrasonic Flow meter for Flush Pumps (01 nos. for all two units of DTPS) header Discharge Line for unit 6 &7 DTPS. Type of Flow sensor: Full Bore Type \n Medium: Clean Raw water \n Fluid velocity: 2-3 m/s \n material of Pipe= MS Line Operating Pressure: 2 Kg/cm2 \n Maximum Pressure: 5 kg/cm2 \n Maximum flowrate:965 m3/hr \nLine Size: 400 mm NB\nitem101Nos.
1111Clamp ON Ultrasonic Flow meter for FAHP Pumps \n( 03 nos. for all two units of DTPS) Common header Discharge Line for unit 6 &7 DTPS. \n Type of Flow sensor: Full Bore Type \n Medium: Clean Raw water \n Fluid velocity: 2-3 m/s \nMaterial of Pipe= MS Line Operating Pressure: 7.5 Kg/cm2 \n Maximum Pressure: 15 kg/cm2 \n Maximum flowrate: 1050 m3/hr.\nLine Size: 350 mm NB\nitem111Nos.
1212Clamp ON Ultrasonic Flow meter for FAHP Pumps \n( 03 nos. for all two units of DTPS) Common header Discharge Line for unit 6 &7 DTPS. \n Type of Flow sensor: Full Bore Type \n Medium: Clean Raw water \n Fluid velocity: 2-3 m/s \nMaterial of Pipe= MS Line Operating Pressure: 7.5 Kg/cm2 \n Maximum Pressure: 15 kg/cm2 \n Maximum flowrate: 1050 m3/hr.\nLine Size: 200 mm NB\nitem121Nos.
1313Clamp ON Ultrasonic Flow meter for recirculation line from Bottom Sludge Tank to Suction tank of ash water Pumps, Two recirculation line for unit 6 &7 DTPS. \n Type of Flow sensor: Full Bore Type \n Medium: Clean Raw water \n Fluid velocity: 2-3 m/s \n material of Pipe= MS Line Operating Pressure: 7.5 Kg/cm2 \n Maximum Pressure: 15 kg/cm2 \n Maximum flowrate:1050 m3/hr\nLine Size: 300 mm NB\nitem131Nos.
1414Clamp ON Ultrasonic Flow meter for recirculation line from Bottom Sludge Tank to Suction tank of ash water Pumps, Two recirculation line for unit 6 &7 DTPS. \n Type of Flow sensor: Full Bore Type \n Medium: Clean Raw water \n Fluid velocity: 2-3 m/s \n material of Pipe= MS Line Operating Pressure: 7.5 Kg/cm2 \n Maximum Pressure: 15 kg/cm2 \n Maximum flowrate:1050 m3/hr\nLine Size: 200 mm NB\nitem141Nos.
1515HMI with Touch Screen one for ATPS&BTPS and other one for DTPSitem152Nos.
1616Magnetic flow data logger with continuous data connectivity to CPCB/UPCPCB server through GSM 4G/3G/@G modem with 05 year License one for ATPS&BTPS and other one for DTPSitem162Nos.
1717AC control panel (PORTA cabin) with standard fitting like AC SPD, Power supplies, MCB, terminal Blocks, standard Key Lockitem172Nos.
1818Central monitoring systemitem182Nos.
1919Air conditioner control panelitem192Nos.
2020Erection, Installation testing and commissioning of electromagnetic Flow meters Equipment along with all accessories as mentioned above and as per requirement of pollution control Boarditem201job
2121Comprehensive Maintenance Contract for routine, Preventive/breakdown maintenance of all installed system(Per month charges should be quoted in BOQ)item2136job

AI Tender Summary

OUR REF NO 24206411
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 1.63 Crore
LAST DATE 14-05-2020
Authority
Authority Name Uttar Pradesh Rajya Vidyut Utpadan Nigam Limited
Work Description 908/Epd-Ii/Btps/Anp/2020-21 Supply , Installation And Commissioning Of Magnetic Flow Meters For Atp , Anpara , Electromagnetic Flow Meter For Lp Pumps ( 04 Nos . Pumps For Each Unit ) Common Header Discharge Line For Unit 4 &5 Btps . Type Of Flow Sensor: Full Bore Type Medium: Clean Raw Water Fluid Velocity: 2-3 M/S Material Of Pipe= Ms Line Line Size: 450 Mm Nb Operating Pressure: 10 Kg/Cm2 Maximum Pressure: 20 Kg/Cm2 Maximum Flowrate: 1260 M3/Hr , Electromagnetic Flow Meter For Hp Pumps ( 04 Nos . Pumps For Each Unit ) Common Header Discharge Line For Unit 4 &5 Btps . Type Of Flow Sensor: Full Bore Type Medium: Clean Raw Water Fluid Velocity: 2-3 M/S Material Of Pipe= Ms Line Line Size:400 Mm Nb Operating Pressure: 14 Kg/Cm2 Maximum Pressure: 20 Kg/Cm2 Maximum Flowrate: 800 M3/Hr , Electromagnetic Flow Meter For Lp Pumps ( 05 Nos . For All Three Units Of Atps ) Common Header Discharge Line For Unit 1 , 2 &3 Atps . Type Of Flow Sensor: Full Bore Type Medium: Clean Raw Water Fluid Velocity: 2-3 M/S Material Of Pipe= Ms Line Working Principle: Faradey Laws Of Electromagnetic Induction Line Size:500 Mm Nb Operating Pressure: 6 . 5 Kg/Cm2 Maximum Pressure: 12 Kg/Cm2 Wire Housing: Welded Sheet Steel Maximum Flow Rate: 1000 M3/Hr , Electromagnetic Flow Meter For Hp Pumps ( 05 Nos . Pumps For All Three Units Of Atps ) Common Header Discharge Line For Unit 1 , 2 & 3 Atps . Type Of Flow Sensor: Full Bore Type Medium: Clean Raw Water Fluid Velocity: 2-3 M/S Material Of Pipe= Ms Line Line Size: 450 Mm Nb Operating Pressure: 10 Kg/Cm2 Maximum Pressure: 20 Kg/Cm2 Maximum Flowrate:1000 M3/Hr , Electromagnetic Flow Meter For Awrs Pumps For Dtps Discharge Line For Unit 6&7 . Type Of Flow Sensor: Full Bore Type Medium: Awrs Pond Water Fluid Velocity: 2-3 M/S Material Of Pipe= Ms Line Working Principle: Faradey Laws Of Electromagnetic Induction Line Size: 800 Mm Nb Operating Pressure: 12-15 Kg/Cm2 Maximum Design Pressure: 20 Kg/Cm2 Wire Housing: Welded Sheet Steel Maximum Flowrate: 4000 M3/Hr Pressure Of Awrs Water:<16 Kg/Cm2 , Electromagnetic Flow Meter For Awrs Pumps For Atps & Btps Discharge Line For Unit 1 To 5 . Type Of Flow Sensor: Full Bore Type Medium: Awrs Pond Water Fluid Velocity: 2-3 M/S Material Of Pipe= Ms Line Working Principle: Faradey Laws Of Electromagnetic Induction Line Size: 500 Mm Nb Operating Pressure: 12-15 Kg/Cm2 Maximum Design Pressure: 20 Kg/Cm2 Wire Housing: Welded Sheet Steel Maximum Flowrate: 3000 M3/Hr Pressure Of Awrs Water:<16 Kg/Cm2 , Clamp On Ultrasonic Flow Meter For Balp Pumps ( 03 Nos . Balp For All Two Units Of Dtps ) Common Header Discharge Line For Unit 6&7 Dtps . Type Of Flow Sensor: Clamp On Type Medium: Clean Raw Water Fluid Velocity: 2-3 M/S Material Of Pipe= Ms Line Operating Pressure: 2 . 5 Kg/Cm2 Maximum Pressure: 5 . 0 Kg/Cm2 Maximum Flowrate:1210 M3/Hr . Line Size: 400 Mm Nb , Clamp On Ultrasonic Flow Meter For Balp Pumps ( 03 Nos . Balp For All Two Units Of Dtps ) Common Header Discharge Line For Unit 6&7 Dtps . Type Of Flow Sensor: Clamp On Type Medium: Clean Raw Water Fluid Velocity: 2-3 M/S Material Of Pipe= Ms Line Operating Pressure: 2 . 5 Kg/Cm2 Maximum Pressure: 5 . 0 Kg/Cm2 Maximum Flowrate:1210 M3/Hr . Line Size: 300 Mm Nb , Clamp On Ultrasonic Flow Meter For Bahp Pumps ( 02 Nos . For All Two Units Of Dtps ) Common Header Discharge Line For Unit 6&7 Dtps . Type Of Flow Sensor: Full Bore Type Medium: Clean Raw Water Fluid Velocity: 2-3 M/S Material Of Pipe= Ms Line Operating Pressure: 9 . 0 Kg/Cm2 Maximum Pressure: 15 . 0 Kg/Cm2 Maximum Flowrate: 1050 M3/Hr . Line Size: 300 Mm Nb , Clamp On Ultrasonic Flow Meter For Flush Pumps ( 01 Nos . For All Two Units Of Dtps ) Header Discharge Line For Unit 6 &7 Dtps . Type Of Flow Sensor: Full Bore Type Medium: Clean Raw Water Fluid Velocity: 2-3 M/S Material Of Pipe= Ms Line Operating Pressure: 2 Kg/Cm2 Maximum Pressure: 5 Kg/Cm2 Maximum Flowrate:965 M3/Hr Line Size: 400 Mm Nb , Clamp On Ultrasonic Flow Meter For Fahp Pumps ( 03 Nos . For All Two Units Of Dtps ) Common Header Discharge Line For Unit 6 &7 Dtps . Type Of Flow Sensor: Full Bore Type Medium: Clean Raw Water Fluid Velocity: 2-3 M/S Material Of Pipe= Ms Line Operating Pressure: 7 . 5 Kg/Cm2 Maximum Pressure: 15 Kg/Cm2 Maximum Flowrate: 1050 M3/Hr . Line Size: 350 Mm Nb , Clamp On Ultrasonic Flow Meter For Fahp Pumps ( 03 Nos . For All Two Units Of Dtps ) Common Header Discharge Line For Unit 6 &7 Dtps . Type Of Flow Sensor: Full Bore Type Medium: Clean Raw Water Fluid Velocity: 2-3 M/S Material Of Pipe= Ms Line Operating Pressure: 7 . 5 Kg/Cm2 Maximum Pressure: 15 Kg/Cm2
Basic Detail
Tender No 908/EPD-II/BTPS/ANP/2020-21
Bidding Type Tender
Location
City ANPARA SONEBHADRA
State Uttar Pradesh
Key Dates
Publish Date 24 Apr 2020
Submission Date 14 May 2020
Open Date 15 May 2020
Finance
Tender Value 1.63 Crore
Tender Fee 4720
EMD 3 Lakhs
Exemption Not Available
Document List
BOQ_687575.xls
8CAB9A5E-066B-43C0-AFE9-D728AEBBA4DB.html
TenderSpecification908.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Apr 24, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
May 14, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
May 15, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xls

BOQ_687575.xls

html

8CAB9A5E-066B-43C0-AFE9-D728AEBBA4DB.html

pdf

TenderSpecification908.pdf

pdf

Tendernotice_1.pdf

TenderDetail
Loading tenders