| 1 | 0 | Note 1: (Applicable for all parts/items) : The bidders/contractors are advised to read tender document, all drawings & all corrigendum/amendments and general condition of contracts before entry/quoting the rates.\nNote 2:- Attention to bidder is hereby invited to upload revised BOQ if published during their bid submission. Uploading of incorrect/ pre-revised BOQ shall be treated as non bonafide and rejected. Fixed credit has been given in technical documents which shall be taken into account during acceptance of bid/tender. | | | |
|---|
| 2 | 1 | Excavating in trenches n.exc 1.5m wide and n.exc 1.5m in depth for cable pipe and foundations etc and getting out in soft/loose soil complete all as specified and directed. | | 176.725 | Cum |
|---|
| 3 | 2 | Returning filling in soft/loose soil, including, spreading leveling waterring and well ramming in layers not exc. 25 cm complete all as specified and directed. | | 157.309 | Cum |
|---|
| 4 | 3 | Removing excavated soils to a distance not exceeding 50 mtrs and depositing where directed at a level n. exc 1.5m above the starting point complete all as specified and directed. | | 19.4156 | Cum |
|---|
| 5 | 4 | Taking down LT UG Cables of any size from trenches/poles complete after disconnection all as specified and directed. | | 256 | RM |
|---|
| 6 | 5 | Supply, laying, jointing and testing LT cable in trenches or on poles/walls, XLPE insulated screened, PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm, 4 core complete all as specified and directed.\nNote : Excavation and earth work will be measured and paid seperately. | | 256 | RM |
|---|
| 7 | 6 | Supply and laying XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty 11000 volts grade with stranded aluminium conductor or size 3.5 core120sqmm complete all as specified and directed. | | 45 | RM |
|---|
| 8 | 7 | Supply and lay PCC cable cover,unre-inforced class LV, type I, flat of size 250mm x 150mm x 40mm over sand cushioning for cable protection complete all as specified and directed. | | 330 | Each |
|---|
| 9 | 8 | M&L for river sand, washed,screened dry sand cushioning 8cm thick below the cable & 15cm above the cable and punned down to 10cm from top of cable complete all as specified and directed.\nNote-Sand shall be completely free from organic and other harmful matters,Total spread thickness shall be 23 cm and punned thickness of 18cm after required compaction shall only be considered for payment) | | 15.5 | Cum |
|---|
| 10 | 9 | M&L for bricks sub-class 'B' laid in trenches with width equal to width of the brick for the protection of under ground cable complete all as specified and directed. | | 1 | Per 1000 |
|---|
| 11 | 10 | M&L for horizontal boring under roads for insertion of pipes upto 150mm bore by manual drilling complete all as specified and as directed. | | 12 | RM |
|---|
| 12 | 11 | M&L for providing cement conceret 1:3:6 type C1 (Using 20mm graded crushed stone aggregate) complete all as specified and as directed. | | 3 | Cum |
|---|
| 13 | 12 | M&L for construction of valve chamber in replacement 1200 x 1200 x1200 mm internal dimensions, 6 mm thick MS sheet cover with 2 Nos MS hinges welded to angle iron frame of 40mm x 40mm x 6 mm thick with lifting hook and locking arrangement complete with necessary earth work, brick work in CM (1:6), 230 mm thick, PCC bed (1:4:8) type D2 150 mm thick, cement plastering, finishing 15 mm thick in CM (1:4) and applying a coat of black bituminous paint to the steel surfaces including dismantling and removal of old unserviceable valve pit remains complete all as specified and as directed. | | 4 | Each |
|---|
| 14 | 13 | Taking up cast iron water mains 150mm dia (including all fittings) with spigot and socket ends and lead joints and recovering lead complete all as specified and directed. | | 415 | RM |
|---|
| 15 | 14 | M&L for taking out existing cast iron sluice valve 150/100/80 mm dia complete all as specified and directed. | | 4 | Each |
|---|
| 16 | 15 | Supply, laying, jointing and testing of Ductile iron (DI) pipes 150 mm (6\") bore with spigot and socket ends, centrifugally cast, class K-7 as per IS:8329-2000 and other relevant standards including material and labour for push on EPDM/SBR Rubber gasket joint in any length laid in trenches complete all as specified and as directed. \n(Note :- DI fittings and earth work will be measured and paid under relavant item of this schedule). | | 415 | RM |
|---|
| 17 | 16 | M&L for DI fittings such as Bends, Tapers, Tees, Branch (Single or double branch), connecting pieces etc., any type and angle/ radius etc.confirming to IS 9523-2000 for DI Pipe upto 200 mm bore complete all as specified and as directed. | | 250 | Kg |
|---|
| 18 | 17 | Supply and fix in repair cast iron sluice valve with stainless steel spindle and cast iron hand wheel complying with IS : 14846-2000, class PN 1.6 both ends flanged with 2 Nos rubber gasket joints, nuts, bolts & washers of required size & Nos complete of following bore size complete all as specified and as directed :- | | | |
|---|
| 19 | 17.01 | (a) 150 mm bore | | 2 | Each |
|---|
| 20 | 17.02 | (b) 100 mm bore | | 2 | Each |
|---|
| 21 | 18 | M&L for 40mm dia GI tubing light grade with all necessary fittings laid in trenches fixed to walls/poles/under road/floor etc for cable protection, complete all as specified and directed | | 12 | RM |
|---|
| 22 | 19 | Dismantling & Taking down unserviceable street light fittings HPSV/FTL fittings from pole for replacement of old type unserviceable fittings complete all as specified and as directed.\n | | 160 | Each |
|---|
| 23 | 20 | S&F servo controlled Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 200 KVA complete all as specified and directed. | | 2 | Each |
|---|
| 24 | 21 | S&F ON LOAD change over switch 415 Volt in sheet metal enclosures 4 pole of capacity 315 Amp complete all as specified and directed. | | 2 | Each |
|---|
| 25 | 22 | S&F Energy saving and environment friendly long life LED street light made up of pressure die cast aluminium with high power LED 36 W as lighting source and lens embeded PC cover having IP 66 protection and impact resistance of IK 07 with 10KV Built-in surge protective device including security light bracket medium grade GI tube 32/40mm with clamps for fixing street light on LT RCC/steel poles complete all as specified and as directed.\nMake- Phillips Cat Part No - BRP050 LED 036 CW R1 MF PC S1 PSU GR or Equivalent of (i) Crompton (ii) Wipro (iii) GE | | 160 | Each |
|---|
| 26 | 23 | M&L for Thermoplastic Cable Junction Boxes IP66/67 \"weather proof\", for outdoor installation with knockouts for cable entry for streetlight with terminals suitable for 10-16 sqmm cable of Size 155 X 210 X 92 mm incl aluninium busbar and MCB SP 6 amps 1 No, for street light, including necessary clamps for fixing with street light pole, and connecting all incoming and outgoing cables with Al lugs of appropiate sizes complete all as specified and as directed.\nMake Cat No. KF1616G of Hensel or euivalent in sintex. | | 15 | Each |
|---|
| 27 | 24 | S&F Timelite Distribution Boards for automatic switching of street lights suitable for 32Amps,3 Pole 230 Volt fited with ASTRONOMICAL time switch 24 hrs operation,3 pole contactor, and TPN MCB,including fixing with MS Clamp 40X5 mm to steel/RCC poles incl connection complete all as specified and directed.\nMake:- Indo Asian Cat No-TL032ASO or Equivalent of L&T/Schneider/Legrand . | | 3 | Each |
|---|
| 28 | 25 | M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metre below ground level) with top edge of the earth plate not less than 1.5 metre below ground level, connected to GI earth wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part I connected to earth test point all as specified including excavation and connected earth work, in soft/loose soil, removing soil upto 50m, PCC 1:3:6 type C1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 15mm bore GI medium grade earth lead protection pipe, 50mm thick RCC 1:2:4 type B1 cover slab of earth pit reinforced with 8 mm dia TMT Bars @ 10cm C/C both ways and with handle made out of 12mm dia bars, funnel, strainer, alternate layer of charcoal dust and common salt and testing on completion, complete all as specified and directed. | | 2 | Each |
|---|
| 29 | 26 | Supply & Erecting Steel Tubular Swaged Pole Type 410-SP-31 (9.0 mtrs long) including Cast Iron Base Plate, Finial Taper Plug, Cap, Mild Steel Bolts, Nuts, Screws including applying two coats of Black Bituminous paint from bottom End of Pole upto PCC Coping and applying with two coats of Aluminium Paint over a coat of Primer (Externally from Top of Coping), including necessary earth work, excavation, PCC 1:3:6 using 40mm graded sone aggregate for foundation and coping with PCC 1:2:4 using 20mm stone aggregate and smooth finish complete all as specified and as directed. | | 15 | Each |
|---|