Military Engineer Services-MES has published Spl Repair/Replacement Of Automatic Meter Reading And Billing System Incl Supply And Installation Of Meters Against Ber Elect Meter In Khetrapal Offrs Enclave At Amritsar Cantt. Submission Date for this Tender is 09-06-2020. Meter Reading Work Tenders in GE Amritsar Punjab. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 01-May-2020 | Corrigendum No 1 | BOQ | 13-05-2020 |
2 | 11-May-2020 | Corrigendum No 2 | Other | 13-05-2020 |
3 | 12-May-2020 | Corrigendum No 3 | Date | 20-05-2020 |
4 | 18-May-2020 | Corrigendum No 5 | Date | 26-05-2020 |
5 | 22-May-2020 | Corrigendum No 6 | Other | 26-05-2020 |
6 | 26-May-2020 | Corrigendum No 7 | Date | 02-06-2020 |
7 | 28-May-2020 | Corrigendum No 8 | Other | 02-06-2020 |
8 | 02-Jun-2020 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 09-06-2020 |
Name of Work: SPL REPAIR/REPLACEMENT OF AUTOMATIC METER READING AND BILLING SYSTEM INCL SUPPLY AND INSTALLATION OF METERS AGAINST BER ELECT METER IN KHETRAPAL OFFRS ENCLAVE AT AMRITSAR CANTT | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Supply and Installation of AC Single Phase Two Wire, Tamper Proof, Static Meter of Class 1.0, 240 V, 50 Hz, basis current 10 A, Max continuous current 600% of basis current conforming to IS-13779 and relevant IEC standards with inbuilt Low Power Radio Frequency (LPRF) communication facility in 865-867 MHz Cyantech or equivalent Mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LED/LCD based circuitry. \nNote: Old unserviceable meters shall be deposited in the MES Storeyard of AGE E/M.\n\n | 136 | Each | |
2 | 2 | Supply and installation of D9Data Concentrator Unit (DCU) compatible for remote Automatic Meter Reading (AMR) solution and capable of communicating with the static energy Meter in the corresponding frequency band of 865-867 MHz Cyantech or equivakent Mesh Network and with the data server through GPRS and shall have minimum data transfer rate of 9600 bps, internal memory to store billing data of 50 modules for 6 month period \nMake - L&T, Schneider, Secure | 4 | Each | |
3 | 3 | Supply oif Installation of+D10 Repeater unit with inbuilt Low Power Radio Frequency (LPRF) Communication Facility in 865-867 MHz Cyantech or equivalent mesh network with inbuilt AC power supply. Single Phase meter may be used as repeater.\nMake: L&T, Schneider, Secure | 2 | Each | |
4 | 4 | Configuration of Cloud Hosted multi user web based Software with following modules:\n(i) Meter Data Management Module\nThe meter data management module would be responsible for collecting the data from the concentrator and make the data available to the billing system. The system would support offline meter data entry. The meter data management system would capture and provide the following data:\n(a) 30 min instantaneous data from all the meters for seven parameters – Cumulative Energy, Cumulative Apparent Energy, Power, Current, Voltage, Power Factor and Frequency\n(b) Monthly and quarterly billing survey data for cumulative energy and max demand\n(ii) Billing Module\nThe billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data / billing data available to admin and end users.\n(iii) Occupation and Vacation Module: \nThe system would support occupation / vacation based on the unit categories. The system would support automatic data capture on occupation and vacation events. It would include Android mobile app aswell.\n(iv) Customer Portal\nThe system would include a customer portal for the resident /occupant to log in and view their own energy / billing data.\n(v) Energy Accounting Module\nThe system would include features of energy accounting. The system would be able to account for total energy block wise, facility wise and would also allow calculations of unaccounted energy in case total energy meter is also available.\n(vi) Communication Module\nThe system would provide communication of energy data and bills via print, email and sms methods.\n(vii) Meter Master Data\nThe system would support meter master data repository. The system would support meter replacement process.\n(viii) Excel Export\nThe system would support export of metering and billing data in excel format. Make: Innologix, L&T, Schneider\nNotes : (i) The rate quoted shall be deemed to include three year maintenance including software hoisting, GPRS charges and trouble shooting and inclusive of hardware replacement.\n(ii) The period of three year shall commence from the certified date of completion of work be GE.\n(iii) The Contractor shall lodge a guarantee/security as specified in Particular Specification on non-judicial stamp paper. | 136 | Each Meter |