Jaipur Metro Rail Corporation Limited-JMRC has published Design Detail Engineering Supply Erection Testing And Commissioning Of Reactive Power Compensation And Power Quality Improvement Devices Shunt Reactor Statcom At 33Kv Level Along With Associated Equipment Integration With Existing Protection. Submission Date for this Tender is 25-06-2020. Couplings Tenders in JAIPUR Rajasthan. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 15-May-2020 | Corriegendum 1 | Date | 10-06-2020 |
2 | 15-May-2020 | Corriegendum | Technical Bid | 10-06-2020 |
3 | 09-Jun-2020 | Corrigendum 02 | Date | 25-06-2020 |
Name of Work: "Design, Detail Engineering, Supply, Erection, Testing and Commissioning of Reactive Power Compensation and power quality improvement devices (Shunt Reactor & STATCOM) at 33kV level along with associated equipment & integration with existing protection and SCADA system at two Receving Substation of Jaipur Metro Rail Corporation Limited" | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Design, Detail Engineering, Supply, Erection, Testing and Commissiong of Reactive Power Compensation and Power Quality improvement devices (Shunt Reactor and STATCOM) at 33 kV level along with associated equipments & integration with existing protection and SCADA system at two number Receiving Substations of (Mansarovar and Sindhi Camp) Jaipur Metro Rail Corporation Limited\n | |||
2 | 1.1 | Fixed/Shunt Reactors with associated equipments | item1 | 2 | MVAR |
3 | 1.2 | Dynamic VAR Compensator (STATCOM) with associated coupling transformer and other associated equipments. | item2 | 3 | MVAR |
4 | 2 | 2 Comprehensive Annual Maintenance Contract for 5 years beyond Defect Liability Period. | item3 | ||
5 | 2.1 | Fixed/Shunt Reactors with associated equipments | item4 | 2 | per MVAR 1st year |
6 | 2.2 | Dynamic VAR Compensator (STATCOM) with associated coupling transformer and other associated equipments. | item5 | 3 | per MVAR 1st year |
7 | 2.3 | Fixed/Shunt Reactors with associated equipments | item6 | 2 | per MVAR 2nd year |
8 | 2.4 | Dynamic VAR Compensator (STATCOM) with associated coupling transformer and other associated equipments. | 3 | per MVAR 2nd year | |
9 | 2.5 | Fixed/Shunt Reactors with associated equipments | 2 | per MVAR 3rd year | |
10 | 2.6 | Dynamic VAR Compensator (STATCOM) with associated coupling transformer and other associated equipments. | 3 | per MVAR 3rd year | |
11 | 2.7 | Fixed/Shunt Reactors with associated equipments | 2 | per MVAR 4th year | |
12 | 2.8 | Dynamic VAR Compensator (STATCOM) with associated coupling transformer and other associated equipments. | 3 | per MVAR 4th year | |
13 | 2.9 | Fixed/Shunt Reactors with associated equipments | 2 | per MVAR 5th year | |
14 | 3 | Dynamic VAR Compensator (STATCOM) with associated coupling transformer and other associated equipments. | 3 | per MVAR 5th year |