Special Repairs To External Electrical Supply At Aizwal Mil Stn, AIZWAl-Meghalaya

Military Engineer Services-MES has published Special Repairs To External Electrical Supply At Aizwal Mil Stn. Submission Date for this Tender is 01-06-2020. Electrical Maintenance Tenders in AIZWAl Meghalaya. Bidders can get complete Tender details and download the document.




Tender Notice

24190520
Corrigendum : Special Repairs To External Electrical Supply At Aizwal Mil Stn
Open Tender
Indian
Meghalaya
AIZWAl
01-06-2020

Tender Details

Special Repairs To External Electrical Supply At Aizwal Mil Stn

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-Apr-2020 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 04-05-2020
2 06-May-2020 Corrigendum_2 Date 11-05-2020
3 12-May-2020 Corigendum_3 Date 18-05-2020
4 14-May-2020 Amendment_corrigendum Other 18-05-2020
5 19-May-2020 Corrigendum_4 Date 25-05-2020
6 26-May-2020 Corrigendum_5 Date 01-06-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 25300.0 /-
Tender Value
INR 12.61 Lakhs /-

BOQ Items

Name of Work: SPECIAL REPAIRS TO EXTERNAL ELECTRICAL SUPPLY AT AIZWAL MIL STN.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre depth foundation of poles, cables etc not exceeding 10 sqm on plan area and getting out in soft / loose soil complete all as specified and as directed. 8 Cum
2 2 Returning, filling in, of soil including spreading leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed . 6 Cum
3 3 Removing excavated material to a distance n.exc 50M and deposited/ spreaded where directed at a level n. exc 1.5 M above the starting point complete all as specified and as directed . 2 Cum
4 4 Materials and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of Under ground cable including spreading and punning down to desired thickness complete all as specified and as directed. (Note: Punned thickness shall be measured for payment purpose) 2 Cum
5 5 Materials and labour for brick protection cover to underground cables with sub class ‘B’ over burnt brick of size 23 X 11.5 X 7.5 cm, (locally available best quality), laid dry and flat abutting each other with gaps not exceeding 10mm complete all as specified and as directed. 2350 Each
6 6 Material and labour for brick work with sub class `B` bricks, old size, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and as directed. 8 Cum
7 7 Supply and laying GI tubing 40mm bore light grade with fittings laid in trenches or for road crossing for protection of LT underground cables including taking up/down unserviceable pipe complete all as specified and as directed.\n 30 Rm
8 8 Supply and laying GI tubing 25mm bore light grade with fittings laid in trenches or for road crossing for protection of LT underground cables including taking up/down unserviceable pipe complete all as specified and as directed.\n 30 Rm
9 9 Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 16 Sqmm 4 core laid in trenches or fixed to wall / pole / ceiling as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc including taking down unservicable cable complete all as specified and as directed.\n\nNote : Earth work, brick protection and sand cushioning and GI Pipe will be measured and paid separately under respective item. 130 Rm
10 10 Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 10 Sqmm 2 core laid in trenches or fixed to wall / pole / ceiling as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc including taking down unservicable cable complete all as specified and as directed.\n\nNote : Earth work, brick protection and sand cushioning and GI Pipe will be measured and paid separately under respective item. 220 Rm
11 11 Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 6 Sqmm 2 core laid in trenches or fixed to wall / pole / ceiling as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc including taking down unservicable cable complete all as specified and as directed.\n\nNote : Earth work, brick protection and sand cushioning and GI Pipe will be measured and paid separately under respective item. 295 Rm
12 12 Supply and fixing steel tubular swaged pole, type 410 SP 22 (Overall length 8.50 meter) conforming to IS-2713 (Part 1 to 3) 1980 complete with cast iron base plate, finial taper plug, bolts, nuts and washers, screws. Pole shall be painted with two coat of black bituminous throughout internally and externally upto planting depth and the remaining external portion shall be painted with two coats of aluminum paints over a coat of red oxide primer, including painting of red & white alternate strips of 30cm each externally from ground level upto 1.2m with synthetic enamel paint, numbering of poles including taking down existing wooden / RCC pole after demolition of PCC complete all as specified and as directed.\n(Note: Excavation and earth work and PCC shall be measured and paid separately under respective items)\n 14 Each
13 13 Supply and fixing in repair / replacement PVC junction box of thermoplastic materials with IP-65 protection level, hinged door and locking arrangement, weather proof and facilited for cable entry in and exit out of size 150 mm x 100 mm shall be fixed with and including necessary fixing clamps, nuts, bolts, washers of suitable size with pole comprising with PVC connector and one MCB SP 10 KA, C series including taking down old unserviceable one complete all as specified and directed. 14 Each
14 14 Supply and fixing MCCB 4 pole 125 amps, 415 volts adjustable type with breaking capacity 16 KA including taking down old unserviceable one complete all as specified and as directed.\n 4 Each
15 15 Supply and fixing MCCB 4 pole 100 amps, 415 volts adjustable type with breaking capacity 16 KA including taking down old unserviceable one complete all as specified and as directed.\n 4 Each
16 16 Supply and fixing MCB DB TPN 4 ways double door including 200 amps rated bus bar, neutral link, earth bar and din rail on wall including taking down old unserviceable DB alongwith MCBs complete all as specified and as directed.\n 8 Each
17 17 Supply and fixing on load change over switch 3 phase , 415 volts, AC supply of capacity 63 amps including taking down unserviceable one complete all as specified and directed. 3 Sqm
18 18 Supply and fixing in repair / replacement expulsion type drop out fuse single pole mounted on insulator for 11000 volt and current rating upto 100 Amps complete all as specified and as directed. \nMake: Pactil/BHEL/Jaypuria Brothers 6 Each
19 19 Supply, install, testing and commissioning of lightening arrestor expulsion type complete with all fitings, transmission class, discharge capacity 65 KA suitable for working voltage of 11000 Volts including all necessary fittings all as per IS-3070 Part-III and IEC 1994 including dismantling of old unserviceable one complete all as specified and as directed.\nMake: Alpro/Areva/Oblum/Rastriya/Raychem/Bhal /ABB 2 Each Set of three
20 20 Supply and fixing as in replacement energy saving and environmental friendly long life LED street light of 40 Watt made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening seperate driver compartment with IP66 protection and impact resistance of IK07 with and including fixing bracket made of 32mm bore galvanised iron light grade pipe made to shape having overall length 1.2 mtr ,fixed over the vertical wall / pole through two numbers mild steel clamp of 25mm width with necessary accessories and electrical connection including taking down old unserviceable fittings complete all as specified and as directed. (Make: CAT NO. ENDURAPEARLNEOSL40WLED757PASYTOPC of Havells or equivalent model of Philips / Bajaj.)\n 24 Each
21 21 Supply and fixing as in replacement energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium flood light of 50 Watt with high power LEDs as light source, suitable for highlighting architectural features with and including fixing bracket made of 32mm bore galvanised iron light grade pipe made to shape having overall length 1.2 mtr ,fixed over the vertical wall / pole through two numbers mild steel clamp of 25mm width with necessary accessories and electrical connection including taking down old unserviceable fittings complete all as specified and as directed. (Make: CAT NO. JETACOMPECTOFL50WLED757LTG of Havells or equivalent model of Philips / Bajaj.)\n 10 Each
22 22 Supply and fixing Decorative gate light made up of high grade unbreakable polycarbonate material LED light fitting suitable for retrofit 20 watt LED lamp B22 base pillar suitable for mounting on gate pillar with GI pipe of suitable dia (minimum 40 mm dia) icluding connectins with 3 core Copper cable of 1.5 sq mm PVC insulated and PVC sheathed of length not more than 0.5 mtr each and PVC connector etc and including 20 Watt LED lamp inside the fitting including taking down old unserviceable fittings complete all as specified and as directed.\n 6 Each
23 23 Supply and fixing crown shape post top lantern in soothing opal finish made up of polycarbonate material suityable upto 15 watt LED lamp with roboust design and efficient light distribution 15 watt available in multiple coherent cilour tyemperatures complete icluding connectins with 3 core Copper cable of 1.5 sq mm PVC insulated and PVC sheathed of length not more than 0.5 mtr each and PVC connector etc and including 15 Watt LED lamp inside the fitting including taking down old unserviceable fittings complete all as specified and as directed.\n 40 Each
24 24 Supply and fixing steel work in tubular trusses i.e truss bottom, top bend, sides, side supports, holding plates, posts and base plate etc. including special shaped washers etc complete using ERW or induction butt welded tubes conforming to IS 1161-1998 grade St-240 etc duly painted with two coats of red oxide primer over a coat of red oxide zinc chrome primer complete all as specified and as directed 110 Kg
25 25 Supply, installing, testing and commissioning LT panel board outdoor type, CPRI approved make, totally enclosed, weather and vermin proof, suitably ventilated 415 volts, 5 cycles, AC supply, factory made, fully compartmentalized made out of 3.15 mm thick CRCA sheet for steel and load bearing and 2.00 mm thick for non load bearing, protection of enclosure IP 54 as per IS-2147 of 1962 with prtetreatment and powder coated of approved colour including suitable size of angle / flat iron frame work alongwith necessary civil works as earthwork / PCC etc including taking down old unserviceable panel board complete comprising the following:- 2 Each Job
26 25.01 (i) Alluminium bus bar of capacity 200 Amps for Phases and 100 amps for neutral. (ii) Ammeter 0 to 100 Amps digital type with built in selecter switch, CTs of suitable ratio -01 Set (iii) Voltmeter digital type with built in selector switch 0 to 500 volts -01 No (iv) ON-OFF indication lamp LED type -03 Nos. INCOMMING (v) MCCB 4 pole, 125 Amps, Breaking capacity 16 KA, Adjustable type -01 No. OUTGOING (vi) MCCB TPN 63 Amps -03 No (vii) MCB SPN 32 Amps -04 Nos. (viii) Street light timer with contactor for street lights single phase 32 Amps.
27 26 Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised wire of 4mm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 15mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion including taking out unserviceable earthing plate and accessories all as specified and as directed. (Note: Earth lead upto a length of 7.50 m from earthplate shall be deemed to be included in quoted rate.) 6 Each Set
28 27 Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of 32 x 6mm size by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion including taking out unserviceable earthing plate and accessories all as specified and as directed. (Note: Earth strip upto a length of 7.50 m from earthplate shall be deemed to be included in quoted rate.) 5 Each Set
29 28 Materials and labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or\nfixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and as directed. 80 Rm
30 29 Materials and labour for earth continuity conductor or main earthing strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or\nfixed to poles or any other indicated situation for loop earthing etc. as required 25 x 3 mm size alluminium strip complete all as specified and as directed. 45 Rm
31 30 Materials and labour for earth continuity conductor or main earthing strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or\nfixed to poles or any other indicated situation for loop earthing etc. as required 32 x 6 mm size alluminium strip complete all as specified and as directed. 60 Rm
32 31 Supply, installation, testing and commissioning Temper proof AC three phase Static energy meter for accuracy class 1.0.3 x 230 Volt 50 Hz with backlit LCD display of rating 10-60 Amps including necessary connection including taking down old unserviceable one complete all as specified and directed. 3 Each
33 32 Supply only Microprocessor based Earth resistance tester, ground resistivity tester with resistance range 0-20 Kilo Ohm mtrs resolution, having accuracy ±1% complete with inbuilt N/Mh rechargeble cell complete all as specified and directed. 1 Each
34 33 Supply and fixing in test terminal box galvanised complete all as specified and as directed.\n 8 Each
35 34 Material and labour of glow sign board made out of 2 mm thick GI sheet, box type with angle iron frame of size 25 x 25 x 4 mm all around edges of GI sheet on five side with rear side openable for maintenance purpose and front side 2 mm thick PVC sheet and computer cut lettering of blue colour with alpha neumeric english letter of suitable sizes and fonts not more than 50 letters in and including 2 x 10 W LED light of 2 ft long complete with mounting arrangement using nuts, bolts of size 0.90 mtr 0.50mtr x 0.05 mtr with connection with service cable AI PVC insulated PVC sheathed 2 x 4 sqmm of length not more than 30 mtrs approximate. Glow sign board shall be fixed to MS pipe frame to a suitable height complete all as specified and directed. 2 Each