Laying 18/16/12 . 75/10 . 75/8 . 625 Inch Od , 1108 Km ( Approx . ) Cross Country Lpg Pipeline From Mp/ Up Border To Iocl Gorakhpur Under Kandla Gorakhpur Lpg Pipeline Project -Group14 Group-14 Iocl Kanpur ( Approx . Ch . 540 . 25 Km Ex-Bpcl Bhopal, UP-Uttar Pradesh

Indian Oil Corporation Limited-IOCL has published Laying 18/16/12 . 75/10 . 75/8 . 625 Inch Od , 1108 Km ( Approx . ) Cross Country Lpg Pipeline From Mp/ Up Border To Iocl Gorakhpur Under Kandla Gorakhpur Lpg Pipeline Project -Group14 Group-14 Iocl Kanpur ( Approx . Ch . 540 . 25 Km Ex-Bpcl Bhopal. Submission Date for this Tender is 06-07-2020. Water Pipe Line Tenders in UP Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

24180388
Corrigendum : Laying 18/16/12 . 75/10 . 75/8 . 625 Inch Od , 1108 Km ( Approx . ) Cross Country Lpg Pipeline From Mp/ Up Border To Iocl Gorakhpur Under Kandla Gorakhpur Lpg Pipeline Project -Group14 Group-14 Iocl Kanpur ( Approx . Ch . 540 . 25 Km Ex-Bpcl Bhopal
Open Tender
Indian
Uttar Pradesh
UP
06-07-2020

Tender Details

Laying 18/16/12 . 75/10 . 75/8 . 625 Inch Od , 1108 Km ( Approx . ) Cross Country Lpg Pipeline From Mp/ Up Border To Iocl Gorakhpur Under Kandla Gorakhpur Lpg Pipeline Project -Group14 Group-14 Iocl Kanpur ( Approx . Ch . 540 . 25 Km Ex-Bpcl Bhopal ) To Hpcl Unnao ( Approx . 603 Km Ex-Bpcl Bhopal ) , Roodapur T Point ( Approx . Ch . 205 Km Ex-Hpcl Unnao ) And Hpcl Unnao To Iocl Lucknow Spurline Ch . 3 Km Ex-Hpcl Unnao )

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-May-2020 Addendum-02 Date 28-05-2020
2 23-May-2020 Addendum-03 Technical Bid 28-05-2020
3 26-May-2020 Addendum-04 Date 15-06-2020
4 15-Jun-2020 Addendum-05 Date 22-06-2020
5 23-Jun-2020 Addendum-06 Date 06-07-2020

Key Value

Document Fees
Refer document
EMD
INR 7374000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Laying 18”/16”/12.75”/10.75”/8.625” OD, 1108 KM (Approx.) Cross Country LPG Pipeline from MP/ UP border to IOCL Gorakhpur under Kandla Gorakhpur LPG Pipeline Project: , Group-14: IOCL Kanpur (approx. Ch. 540.25 Km Ex-BPCL Bhopal) to HPCL Unnao (approx. 603 Km Ex-BPCL Bhopal), Roodapur – T point (approx. Ch. 205 Km Ex-HPCL Unnao) and HPCL Unnao to IOCL Lucknow spurline Ch. 3 Km Ex-HPCL Unnao)
Sl. No. Item Description Item Code / Make Quantity Units
1 1 KGPL Mainline Laying - Group 14 Part 1 Item 00010
2 2 MAINLINE LAYING WORKS: Laying of Owner-supplied pre-coated mild steel line pipes, including arranging all additional land/construction corridor, beyond Owner's ROU/ROW, required for Contractor’s storage, fabrication, access for construction site, movement of construction equipment etc., receiving and taking over Owner-supplied materials, handling, transportation etc. from Owner’s issue point to work site, stringing along Right of Way (ROW)/ pipeline corridor, providing labour, equipment and supply of other inputs & materials/ consumables necessary to perform and complete the work in all respects in accordance with the contract including, but not limited to, the following works:\n# Taking delivery of pre-coated/ bare pipes from the designated stockpile location (loading of pipes onto pipe trailors placed inside stockpile by mainline contractor shall be done by Owner's authorized agency), including placing of pipe trailors for taking delivery of pipes from stockpile, carrying out holiday detection and verification of pipes at the time of taking delivery), transportation of pipes to ROW/ work site/ Contractor's storage location etc.,\n# Clearing and grading of ROW/ pipeline coridor, cutting of trees, vegetation etc. including keeping record of trees cut, including de-watering etc.,\n# Stringing of pipes along ROW including providing straw bags/ soft padding (in Rocky areas requiring blasting for preparation of trench, pipes shall be strung after the blasting operation and clearing of trench and instructions of Site Engineer/ Engineer-in-Charge),\n# Trenching to all depths to maintain clear earth cover as per specification and to fit minimum bend radius, by excavation in all kinds of terrain & soil, including stripping top soil to a depth of 30cm to the full anticipated width of the ditch and storing this material separately along the ROW to allow replacement of this material on top of the backfilled ditch (in cultivable and other areas specially designated by Owner),\n# Carrying out repair of pipe & coating defects for defects occuring after "taking over" of pipes from Owner, replacement in the case of non-repairable defects and repairing damages to pipe coating including defects/ damages occurring during transportation & handling,\n# Aligning, bending, lining up, cutting and bevelling (as required) of pipes for field adjustments, welding (manual / semi-automatic / automatic), physical inspection of all weld joints by qualified welding engineer/ inspector & carrying out repair of weld-joints found defective,\n# Carrying out 100% radiographic inspection of all field weld joints in each Mainline Spread, Crossings and other specific locations as per Specifications and Special Conditions of Contract (SCC) (excluding crossings and other specific locations) and destructive testing of one weld joint in each Spread as per specification and direction of Site Engineer, including providing Crawler type Automatic X-Ray machine and external X-Ray machine and all other requisite equipment, labour, supervision, materials, approved films, approved consumables, all facilities and personnel to process, develop, examine and interpret radiographs (by qualified and experienced Radiography Inspector) and other tests as required, carrying out repair of weld-joints found defective, carrying out re-radiography and other tests as required on repaired joints, etc.,\n Item 10.10
3 3 # Carrying out coating of all field weld joints, by qualified coating insulators, including supply of approved joint coating materials, providing all equipment, materials and consumables necessary to carry out the job as per manufacturer’s recommendation,\n# Installation of hot-pulled bends at required locations in mainline (bends to be fabricated from Owner-supplied bare pipes) including cutting, bevelling, fitment, coating the bare bend pipe with approved cold-applied tape coat / PU coating etc.,\n# Carrying out holiday detection, at specified voltage level corresponding to coating type and as per specifications, and repair of coating, if any,\n# Laying pipeline by open-cut method at crossings viz., cart-track, metalled/ un-metalled roads, minor water courses (MWC), (except crossings identified as "Cased", "Submerged" & "HDD" crossings and "Marshy areas") and restoration of the site to original condition including performance of additional works for strengthening of banks of water courses etc.,\n# Lowering the pipeline in trench, tieing-in, backfilling with excavated earth and/or other suitable soil (top soil stored separately during trenching shall be backfilled on top of the ditch) as directed by Site-Engineer,\n# Carrying out air cleaning, gauge pigging and hydrostatic testing (to specified pressure) of the complete pipeline (excluding those HDD crossing sections not under the scope of this tender) including providing ‘pre-testing’ of designated sections as approved by Engineer-in-Charge, providing all equipment, pumps, fittings, instruments, dead weight tester etc. and services, supervision, labour, consumables, testing of water, supply & injection of corrosion inhibitor, locating leaks, if any, and rectification of defects attributable to Contractor, re-testing after rectification etc. and cleaning the pipeline section after successful hydrotesting,\n# All tie-ins, including tieing-in with HDD sections under this tender,\n# Final clean-up and restoration of ROW/ construction corridor, field bunds etc. and obtaining NOC from statutory authorities as required, disposal of debris and returning surplus material to designated disposal areas/ storage location, as directed by Engineer-in-Charge, restoration of land, facilities and boundary wall etc. for facilities dismantled/ damaged by Contractor during construction, obtaining work permits/ NOC from various authorities having jurisdiction before execution of work and complying with all stipulations/ conditions/ recommendation of the said authorities, obtaining NOC from respective land owners in respect of final restoration of their land etc.,\n# Preparation of as-built drawings, pipe book and other records as per specifications etc.,\n# Supply of all materials (other than those specifically undertaken to be supplied by the Owner under the contract) necessary for performance of work or for temporary or permanent incorporation in the works, and \n# All other acts, deeds, matters and things necessary to make the pipeline ready for commissioning and completing the works, including drone survey in all respects as per drawings, specifications and instructions of Site Engineer/ Engineer-in-Charge. Item 10.10.1
4 4 8.625" OD Item 10.20 3800 M
5 5 16" OD Item 10.30 247620 M
6 6 KGPL Mainline Laying - Group 14 Part 2 Item 00020
7 7 CASED CROSSING WITHOUT OFC DUCT: Laying cased crossings, by auger boring & jacking method, using casing pipes according to drawings, specification(s) and providing all works, labour, inputs and materials/ consumables necessary to perform and complete the works in all respect in accordance with the contract, including collecting the pipes and other Owner-supplied materials from Owner’s issue point and loading, transporting them to site, setting out the works, aligning and welding the casing and carrier pipes, 100% radiography of weld joints of carrier pipes, field joint coating, holiday detection & repair of coating, applying atleast 2(two) coats of bitumastic paint over coat of suitable primer over casing pipe and two component epoxy coating for internal surface of casing pipe, excavating/ trenching and/or boring in all kinds of soil, including rocky strata if any, inserting the casing pipe into the bore, pre-hydrostatic testing of the carrier pipe and replacement / rectification of defects / pipes, installation of approved type of insulators throughout the cased section on the carrier pipe, carefully inserting the carrier pipe inside casing pipe by jacking/ pushing method, taking care not to damage the insulators, sealing the ends of the casing pipe with approved heat shrinkable wraparound type end seal, fixing of vent pipes at the ends of the casing pipe, priming and applying two coats of coal-tar based epoxy paint on underground portion of vent pipes, measuring final resistance between carrier pipe and casing, and doing preparation work necessary to produce correct resistance, applying one coat of primer and two coats of epoxy paint to all exposed and overground fittings & piping, proper compaction of backfill below carrier pipe at either ends, independently supporting the carrier pipe outside each end of the casing pipe by suitable RCC supports with neoprene rubber sheet below the carrier pipe, and strengthening with sand bags and proper compaction of earth below pipe, to prevent differential settlement of carrier pipe and damage to insulators, final clean-up and restoration of the site and disposal of wastes and surplus in accordance with the contract and supply of all materials (other than those specifically undertaken to be supplied by the Owner under contract) necessary for or in the performance of the work or for temporary or permanent incorporation in the works, and all other acts, matters and things necessary to make the pipeline ready for commissioning in all respect, as per directions of Site Engineer/ Engineer-in-Charge. Item 20.10
8 8 16" OD Item 20.20 30 M
9 9 SUBMERGED CROSSING: Laying submerged crossings using pipes with or without concrete sheathing across major water course crossings and providing all works ,labour, inputs and materials/consumable necessary to perform and complete the work in all respects in accordance with the contract, arranging the required additional land for construction purpose, preparation of site, aligning, bending, lining up and welding the pipe, 100% radiographic inspection of weld joints, coating of field weld joints, holiday detection and repair of coating, hydrotesting testing (both pre- & post-installation) and replacement of pipes/ defects, excavation of the trench to required depth, as per specifications, in all kinds of soil and conditions including rock trenching and maintenance of trench in all kinds of soil including rocky strata, if any, making bunds for stoppage of water flow, de-watering including installation of well-point system, and laying of the pipeline in approved trench, including de-watering, providing in-situ concreting at coated weld joints to effectively secure the HDPE conduit with mainline pipe, providing ""Band IT"" make stainless steel (SS) strips / clamps of 3/4"" width for tying HDPE conduit with mainline pipe (two strips per pipe length), backfilling and final clean-up, stabilisation of the excavated banks by additional means, disposal of waste and surplus in accordance with the contract, and supply of materials (other than those specifically undertaken to be supplied by the Owner under the contract) necessary for or in the performance of the work or for temporary or permanent incorporation in the works and all other acts, matters and things necessary to complete the pipeline/ crossings in all respects according to the contract and as per directions of Site Engineer/ Engineer-in-Charge. Item 20.30
10 10 16" OD Item 20.40 920 M
11 11 LAYING PIPELINE IN MARSHY AREA: Laying pre-coated pipes in Marshy areas with concrete sheathing including providing all equipment, works,labour, inputs and materials/consumable necessary to perform and complete the work in all respects, submission of construction procedure for Owner's approval, arranging the required additional land for construction purpose, preparation of site including dewatering, aligning, bending, lining up and welding the pipe, 100% radiographic inspection of weld joints, coating of field weld joints, holiday detection and repair of coating, hydrotesting testing and replacement of pipes/ defects, excavation of the trench to required depth in all kinds of soil and conditions including rock trenching and maintenance of trench in all kinds of soil including rocky strata, if any, and laying of the pipeline in approved trench, backfilling and final clean-up, stabilisation of the excavated banks, disposal of waste and surplus in accordance with the contract, and supply of materials (other than those specifically undertaken to be supplied by the Owner under the contract) necessary for or in the performance of the work or for temporary or permanent incorporation in the works and all other acts, matters and things necessary to complete the work in all respects according to the contract. Item 20.50
12 12 8.625" OD Item 20.60 50 M
13 13 16" OD Item 20.70 550 M
14 14 CONCRETE SHEATING: Providing & Laying Concrete sheathing on the carrier pipe i.e., continuous concrete coating (mix 1:1.5:3) of 50 mm thick using specified (approved) wire mesh reinforcement as per approved drawing and technical specifications, including supply of cement, steel wire mesh, aggregate, sand, shuttering and all other materials, consumables, inputs, equipment for concrete sheathing required to complete the job, testing of concrete coated pipes etc. and as per direction of Engineer-in-Charge. Item 20.80
15 15 8.625" OD Item 20.90 50 M
16 16 16" OD Item 20.100 850 M
17 17 SAND PADDING (AT SEISMIC FAULT LOCATION): Supplying, providing and filling fine sand in trenches at Seismic Fault location crossing or running parallel to pipeline (including additional 500 mm deep & 200/300 mm wide trenching) around mainline pipe for providing a minimum padding thickness of 500 mm on top as well as at bottom of the mainline pipe(for the complete trench width). Item 20.110
18 18 16" OD Item 20.120 2000 M
19 19 SAND PADDING (IN OTHER AREAS): Supplying, providing and filling fine sand in trenches in stretches other than normal soil and hard rock (including additional 150mm deep trenching) around mainline pipe for providing a minimum padding thickness of 150mm on top as well as at bottom of the mainline pipe. Item 20.130
20 20 8.625" OD Item 20.140 100 M
21 21 16" OD Item 20.150 1500 M
22 22 ROCK SHIELD: Supplying & providing approved type of extruded polyethylene mesh (rock shield) on mainline pipe to protect the coating against rocky soil including supply of all inputs such as labour, materials, consumables etc. necessary to perform and complete the work in all respects in accordance with the specifications, manufacturer's recommendation and instructions of Site Engineer / Engineer-in-Charge. Item 20.160
23 23 PIPELINE MARKERS: Supply of all materials necessary for fabrication and installation of kilometre posts, direction markers and warning signs at the locations as per specifications, excavating & grouting in cement concrete 1:3:6, and all other works necessary for fabrication & installation of the markers including cleaning, priming & applying two coats of coal tar based epoxy paint on underground portions, supply and application of one coat of primer and two coats of epoxy paint of approved colour and quality on overground portion, stencil letter cutting for number, direction, chainage etc. and restoration of site to original condition and all other acts, deeds, matters and things and work, labour, inputs and materials/ consumables necessary to perform and complete the work in all respects as per approved drawing & specifications and as per direction of Site Engineer / Engineer-in-Charge. Item 20.170
24 24 KILOMETER POST Item 20.180 290 EA
25 25 DIRECTION MARKER Item 20.190 1690 EA
26 26 WARNING SIGN Item 20.200 1190 EA
27 27 Providing and installing RCC (1:1.5:3) boundary pillars as per drawings on both edges of the ROW at 250 metres interval and at every turning point and/or as directed, including supply of all materials necessary for the fabrication of the pillars, casting and inscr ibing the pillars, excavation of earth, fixing the pillars & backfilling, applying two coats of oil paint over one coat of cement ba sed primer on exposed surface and work, labour, inputs & materials/ consumables necessary to perform and complete the work in all re spect under the contract and as per directions of Site Engineer. Item 20.210 2280 EA
28 28 AIR DRYING (OPTIONAL): Carrying out air drying of the pipeline system as per specification and direction of Engineer-in-Charge including supply of all labour, materials, equipments, instruments, pigs, barrels etc. complete in all respects. Item 20.220
29 29 8.625" OD Item 20.230 5 KM
30 30 10.75" OD Item 20.240 3 KM
31 31 16" OD Item 20.250 270 KM
32 32 NITROGEN PURGING (OPTIONAL): Carrying out Nitrogen Purging of the pipeline system as per specification and direction of Engineer-in-Charge including supply of all labour, materials, equipments, instruments, pigs, barrels etc. complete in all respects. Item 20.260
33 33 8.625" OD Item 20.270 5 KM
34 34 10.75" OD Item 20.280 3 KM
35 35 16" OD Item 20.290 270 KM
36 36 ELECTRONIC GEOMETRY PIGGING (EGP) / CALLIPER SURVEY: Mobilisation/ demobilisation of pigging tools, tackles, consumables, accessories and personnel by contractor at work site including magnetic pig, electronic geometry pig, pig tracking device, preparation and cleaning of the complete mainline / Mainline sections including HDD sections under this tender (but excluding HDD crossings not included under the scope of this tender and to be executed by separate agency) by running series of pigs for cleaning the line from debris, water & making it dry for launching calliper pigs, running of magnetic pig for cleaning of ferrous residue, launching and receiving the electronic & standard calliper pigs, including pig tracking at 5 to 10 km interval, data retrieval, interpretation of data and submission of reports in the form acceptable to the Owner, including rectification of defects observed from calliper survey, including supply of all labour, materials, equipment & instruments, calliper pigs, fabrication of launching & receiving barrels, all complete for ascertaining the geometry of the pipeline. Item 20.300
37 37 8.625" OD Item 20.310 5 KM
38 38 10.75" OD Item 20.320 3 KM
39 39 16" OD Item 20.330 270 KM
40 40 INSTALLATION OF SECTIONALISING VALVES: Taking delivery of MOVs for mainline from Owner's stockpile/ godown, preparation of pup pieces of specified length from owner supplied pipes of higher wall thickness, welding of pup pieces to both sides of valves, providing instrument tappings in MOVs, hydrostatically testing the valves & installing at designated locations on the mainline in accordance with the specifications and drawings, welding & 100% radiography of weld joints, repair of weld joints etc., complete in all respect including all works and material in foundation, RCC underground valve supports etc., including PU Coating of underground portions and painting of overground portions / valve enclosure etc. with aluminium paint over a coat of primer, and including supply of all materials (other than those specifically undertaken to be supplied by the Owner), consumables & inputs complete as per specifications, drawings & instructions of Site Engineer / Engineer-in-Charge. Item 20.340
41 41 16" OD Item 20.350 25 EA
42 42 TIEING-IN AND HOOK-UP WITH HDD SECTIONS (OPTIONAL): Carrying out tieing-in and hook-up with the HDD sections of pipeline on either side of the HDD pipe section, including excavation/ trenching in all kinds of soil including rock, cutting of pipe, making field bends out of pre-tested pipes to match the site requirement, welding, carrying out 100% radiography, field joint coating, holiday detection, repair of damaged coating, backfilling and making through the pipeline etc. complete in all respects Item 20.360
43 43 16" OD Item 20.370 10 EA
44 44 FABRICATION OF HOT PULL INDUCTION BENDS: Taking delivery and transportation of bare pipes from owner's stockpile, transportation, unloading the pipes at manufacturer's works and fabrication of Long Radius (R=6D) Hot pulled induction bends having tangent length of approximately 1000m at both ends as per specification and delivery of hot pulled bends to site including visual examination, manual U.T. on the entire weld seam, bevelling of ends as per API 5L, supply of all materials, consumables, labour etc. as per specifications and direction of Site Engineer / Engineer-in-Charge. Item 20.380
45 45 8.625" OD Item 20.390 10 EA
46 46 16" OD Item 20.400 60 EA
47 47 COMMISSIONING ASSISTANCE FOR LPG PIPELINE: Supply of all materials, consumables, providing all equipment & resources for the complete activity of commissioning of Liquid Petroleum Gas Pipeline (LPG) including Mainline and Stations with proper pressurization of mainline and station piping with Nitrogen, batch pigging followed by vaporized LPG and effective line fill by pressurization of line fill LPG as per approved procedure and Specification requirement including providing expert services for vetting of commissioning procedure and presence of expert to guide & monitor the complete commissioning activities, providing all supervisory/expert services, other manpower and all resources for the execution of the complete service meeting with international practices and standards, observing all statutory and other governing rules & standards in all respect and as per the approved scheme and guidance/direction of Engineer - in - Charge. i) The offer shall be inclusive of supply of nitrogen, pig train, all consumables, taxes, duties as applicable and excluding GST. ii) IOCL's responsibility shall be limited to arrangement of a) Fire tender b) Ambulance c) Water supply d) Providing LPG in tanker truck and subsequently lining up of the pipeline system for LPG line fill. Item 20.410
48 48 8.625" OD Item 20.420 5 KM
49 49 10.75" OD Item 20.430 3 KM
50 50 16" OD Item 20.440 270 KM
51 51 SOFT SOIL PADDING (IN HARD ROCK AREA): Supplying, providing and filling Soft Soil in trenches in hard rocky stretches (excluding additional 150mm deep rock trenching) around mainline pipe for providing a minimum padding thickness of 150mm on top as well as at bottom of the mainline pipe. Padding materials shall be graded soil containing no gravel, rock, or lumps of hard soil. The graded soil for padding shall pass through sieve size ASTM-10 or ISO-2.00. Acceptable padding shall be placed under the pipeline before its installation and around it after installation, to establish at both sides and on top of the pipe a permanent layer of padding. The thickness of compacted padding shall be at least 150mm. The trench shall be deeper by at least 150mm. The trench shall be evenly and sufficiently padded to keep the pipe, when in place, at least 150mm above the bottom of excavated trench. Item 20.450
52 52 8.625" OD Item 20.460 100 M
53 53 16" OD Item 20.470 1500 M
54 54 SOFT SOIL PADDING (IN SEISMIC LOCATIONS): Supplying, providing and filling Soft Soil in trenches at Seismic Fault location crossing or running parallel to pipeline (including additional 500 mm deep & 200/300 mm wide trenching) around mainline pipe for providing a minimum padding thickness of 500 mm on top as well as at bottom of the mainline pipe(for the complete trench width). Padding materials shall be sand/graded soil/other suitable material containing no gravel, rock, or lumps of hard soil. The graded soil for padding shall pass through sieve size ASTM-10 or ISO-2.00. Acceptable padding shall be placed under the pipeline before its installation and around it after installation, to establish at both sides and on top of the pipe a permanent layer of padding. The thickness of compacted padding shall be at least 150mm. The trench shall be deeper by at least 150mm. The trench shall be evenly and sufficiently padded to keep the pipe, when in place, at least 150mm above the bottom of excavated trench. At seismic fault locations, in addition to the above requirements of padding material, in case the dugout soil is clayey in nature (undrained sheer strength > 0.5 T/m2), the local soil shall be replaced by engineered (cohesion less) backfill having angle of friction not more than 27 degrees and the same shall be loosely compacted (unit weight < 1.8 T/m3). In case of undrained sheer strength of the dugout soil <= 0.5 T/m2 the dugout soil itself can be used as backfill. The trench shall be deeper by at least 500 mm. The trench shall be evenly and sufficiently padded to keep the pipe, when in place, at least 500 mm above the bottom of excavated trench. Acceptable padding shall be placed under the pipeline before its installation and around it after installation, to establish at both sides and on top of the pipe a permanent layer of padding. The thickness of compacted padding shall be at least 500 mm. Item 20.480
55 55 16" OD Item 20.490 2000 M
56 56 "Mainline Twin Line Laying: 16" OD + 16" OD IN COMMON TRENCH: Laying of Owner-supplied pre-coated mild steel line pipes, including arranging all additional land/construction corridor, beyond Owner's ROU/ROW, required for Contractor’s storage, fabrication, access for construction site, movement of construction equipment etc., receiving and taking over Owner-supplied materials, handling, transportation etc. from Owner’s issue point to work site, stringing along Right of Way (ROW)/ pipeline corridor, providing labour, equipment and supply of other inputs & materials/ consumables necessary to perform and complete the work in all respects in accordance with the contract including, but not limited to, the following works:\n# Taking delivery of pre-coated/ bare pipes from the designated stockpile location (loading of pipes onto pipe trailors placed inside stockpile by mainline contractor shall be done by Owner's authorized agency), including placing of pipe trailors for taking delivery of pipes from stockpile, carrying out holiday detection and verification of pipes at the time of taking delivery), transportation of pipes to ROW/ work site/ Contractor's storage location etc.,\n# Clearing and grading of ROW/ pipeline coridor, cutting of trees, vegetation etc. including keeping record of trees cut, including de-watering etc.,\n# Stringing of pipes along ROW including providing straw bags/ soft padding (in Rocky areas requiring blasting for preparation of trench, pipes shall be strung after the blasting operation and clearing of trench and instructions of Site Engineer/ Engineer-in-Charge),\n# Trenching to all depths to maintain clear earth cover as per specification and to fit minimum bend radius, by excavation in all kinds of terrain & soil, including stripping top soil to a depth of 30cm to the full anticipated width of the ditch and storing this material separately along the ROW to allow replacement of this material on top of the backfilled ditch (in cultivable and other areas specially designated by Owner),\n# Carrying out repair of pipe & coating defects for defects occuring after "taking over" of pipes from Owner, replacement in the case of non-repairable defects and repairing damages to pipe coating including defects/ damages occurring during transportation & handling,\n# Aligning, bending, lining up, cutting and bevelling (as required) of pipes for field adjustments, welding (manual / semi-automatic / automatic), physical inspection of all weld joints by qualified welding engineer/ inspector & carrying out repair of weld-joints found defective,\n# Carrying out 100% radiographic inspection of all field weld joints in each Mainline Spread, Crossings and other specific locations as per Specifications and Special Conditions of Contract (SCC) (excluding crossings and other specific locations) and destructive testing of one weld joint in each Spread as per specification and direction of Site Engineer, including providing Crawler type Automatic X-Ray machine and external X-Ray machine and all other requisite equipment, labour, supervision, materials, approved films, approved consumables, all facilities and personnel to process, develop, examine and interpret radiographs (by qualified and experienced Radiography Inspector) and other tests as required, carrying out repair of weld-joints found defective, carrying out re-radiography and other tests as required on repaired joints, etc.,\n Item 20.500 3170 M
57 57 # Carrying out coating of all field weld joints, by qualified coating insulators, including supply of approved joint coating materials, providing all equipment, materials and consumables necessary to carry out the job as per manufacturer’s recommendation,\n# Installation of hot-pulled bends at required locations in mainline (bends to be fabricated from Owner-supplied bare pipes) including cutting, bevelling, fitment, coating the bare bend pipe with approved cold-applied tape coat / PU coating etc.,\n# Carrying out holiday detection, at specified voltage level corresponding to coating type and as per specifications, and repair of coating, if any,\n# Laying pipeline by open-cut method at crossings viz., cart-track, metalled/ un-metalled roads, minor water courses (MWC), (except crossings identified as "Cased", "Submerged" & "HDD" crossings and "Marshy areas") and restoration of the site to original condition including performance of additional works for strengthening of banks of water courses etc.,\n# Lowering the pipeline in trench, tieing-in, backfilling with excavated earth and/or other suitable soil (top soil stored separately during trenching shall be backfilled on top of the ditch) as directed by Site-Engineer,\n# Carrying out air cleaning, gauge pigging and hydrostatic testing (to specified pressure) of the complete pipeline (excluding those HDD crossing sections not under the scope of this tender) including providing ‘pre-testing’ of designated sections as approved by Engineer-in-Charge, providing all equipment, pumps, fittings, instruments, dead weight tester etc. and services, supervision, labour, consumables, testing of water, supply & injection of corrosion inhibitor, locating leaks, if any, and rectification of defects attributable to Contractor, re-testing after rectification etc. and cleaning the pipeline section after successful hydrotesting,\n# All tie-ins, including tieing-in with HDD sections under this tender,\n# Final clean-up and restoration of ROW/ construction corridor, field bunds etc. and obtaining NOC from statutory authorities as required, disposal of debris and returning surplus material to designated disposal areas/ storage location, as directed by Engineer-in-Charge, restoration of land, facilities and boundary wall etc. for facilities dismantled/ damaged by Contractor during construction, obtaining work permits/ NOC from various authorities having jurisdiction before execution of work and complying with all stipulations/ conditions/ recommendation of the said authorities, obtaining NOC from respective land owners in respect of final restoration of their land etc.,\n# Preparation of as-built drawings, pipe book and other records as per specifications etc.,\n# Supply of all materials (other than those specifically undertaken to be supplied by the Owner under the contract) necessary for performance of work or for temporary or permanent incorporation in the works, and \n# All other acts, deeds, matters and things necessary to make the pipeline ready for commissioning and completing the works, including drone survey in all respects as per drawings, specifications and instructions of Site Engineer/ Engineer-in-Charge. Item 20.500.1
58 58 Mainline Triple Line Laying: 16" OD + 16" OD + 10.75" OD IN COMMON TRENCH: Laying of Owner-supplied pre-coated mild steel line pipes, including arranging all additional land/construction corridor, beyond Owner's ROU/ROW, required for Contractor’s storage, fabrication, access for construction site, movement of construction equipment etc., receiving and taking over Owner-supplied materials, handling, transportation etc. from Owner’s issue point to work site, stringing along Right of Way (ROW)/ pipeline corridor, providing labour, equipment and supply of other inputs & materials/ consumables necessary to perform and complete the work in all respects in accordance with the contract including, but not limited to, the following works:\n# Taking delivery of pre-coated/ bare pipes from the designated stockpile location (loading of pipes onto pipe trailors placed inside stockpile by mainline contractor shall be done by Owner's authorized agency), including placing of pipe trailors for taking delivery of pipes from stockpile, carrying out holiday detection and verification of pipes at the time of taking delivery), transportation of pipes to ROW/ work site/ Contractor's storage location etc.,\n# Clearing and grading of ROW/ pipeline coridor, cutting of trees, vegetation etc. including keeping record of trees cut, including de-watering etc.,\n# Stringing of pipes along ROW including providing straw bags/ soft padding (in Rocky areas requiring blasting for preparation of trench, pipes shall be strung after the blasting operation and clearing of trench and instructions of Site Engineer/ Engineer-in-Charge),\n# Trenching to all depths to maintain clear earth cover as per specification and to fit minimum bend radius, by excavation in all kinds of terrain & soil, including stripping top soil to a depth of 30cm to the full anticipated width of the ditch and storing this material separately along the ROW to allow replacement of this material on top of the backfilled ditch (in cultivable and other areas specially designated by Owner),\n# Carrying out repair of pipe & coating defects for defects occuring after "taking over" of pipes from Owner, replacement in the case of non-repairable defects and repairing damages to pipe coating including defects/ damages occurring during transportation & handling,\n# Aligning, bending, lining up, cutting and bevelling (as required) of pipes for field adjustments, welding (manual / semi-automatic / automatic), physical inspection of all weld joints by qualified welding engineer/ inspector & carrying out repair of weld-joints found defective,\n# Carrying out 100% radiographic inspection of all field weld joints in each Mainline Spread, Crossings and other specific locations as per Specifications and Special Conditions of Contract (SCC) (excluding crossings and other specific locations) and destructive testing of one weld joint in each Spread as per specification and direction of Site Engineer, including providing Crawler type Automatic X-Ray machine and external X-Ray machine and all other requisite equipment, labour, supervision, materials, approved films, approved consumables, all facilities and personnel to process, develop, examine and interpret radiographs (by qualified and experienced Radiography Inspector) and other tests as required, carrying out repair of weld-joints found defective, carrying out re-radiography and other tests as required on repaired joints, etc.,\n Item 20.510 2960 M
59 59 # Carrying out coating of all field weld joints, by qualified coating insulators, including supply of approved joint coating materials, providing all equipment, materials and consumables necessary to carry out the job as per manufacturer’s recommendation,\n# Installation of hot-pulled bends at required locations in mainline (bends to be fabricated from Owner-supplied bare pipes) including cutting, bevelling, fitment, coating the bare bend pipe with approved cold-applied tape coat / PU coating etc.,\n# Carrying out holiday detection, at specified voltage level corresponding to coating type and as per specifications, and repair of coating, if any,\n# Laying pipeline by open-cut method at crossings viz., cart-track, metalled/ un-metalled roads, minor water courses (MWC), (except crossings identified as "Cased", "Submerged" & "HDD" crossings and "Marshy areas") and restoration of the site to original condition including performance of additional works for strengthening of banks of water courses etc.,\n# Lowering the pipeline in trench, tieing-in, backfilling with excavated earth and/or other suitable soil (top soil stored separately during trenching shall be backfilled on top of the ditch) as directed by Site-Engineer,\n# Carrying out air cleaning, gauge pigging and hydrostatic testing (to specified pressure) of the complete pipeline (excluding those HDD crossing sections not under the scope of this tender) including providing ‘pre-testing’ of designated sections as approved by Engineer-in-Charge, providing all equipment, pumps, fittings, instruments, dead weight tester etc. and services, supervision, labour, consumables, testing of water, supply & injection of corrosion inhibitor, locating leaks, if any, and rectification of defects attributable to Contractor, re-testing after rectification etc. and cleaning the pipeline section after successful hydrotesting,\n# All tie-ins, including tieing-in with HDD sections under this tender,\n# Final clean-up and restoration of ROW/ construction corridor, field bunds etc. and obtaining NOC from statutory authorities as required, disposal of debris and returning surplus material to designated disposal areas/ storage location, as directed by Engineer-in-Charge, restoration of land, facilities and boundary wall etc. for facilities dismantled/ damaged by Contractor during construction, obtaining work permits/ NOC from various authorities having jurisdiction before execution of work and complying with all stipulations/ conditions/ recommendation of the said authorities, obtaining NOC from respective land owners in respect of final restoration of their land etc.,\n# Preparation of as-built drawings, pipe book and other records as per specifications etc.,\n# Supply of all materials (other than those specifically undertaken to be supplied by the Owner under the contract) necessary for performance of work or for temporary or permanent incorporation in the works, and \n# All other acts, deeds, matters and things necessary to make the pipeline ready for commissioning and completing the works, including drone survey in all respects as per drawings, specifications and instructions of Site Engineer/ Engineer-in-Charge. Item 20.510.1
60 60 HDD INSTALLATION (Carrier Pipe with OFC duct): -Design, detailed engineering & installation of pipeline / pipeline & OFC conduit across rivers, NH, SH, Expressways, Railways, etc by HDD method.,, -Complete work for the crossing (between the limits, as indicated in the approved drawings) including mobilization & de-mobilization at site(s), supply of all materials as per the `Scope of Supply' and all consumables, equipment, manpower & other resources and arranging the required land for site preparations and execution of, but not limited to, the following works in accordance with the specifications, drawings and as per all provisions of the contract document and instructions of the Owner.,, -Interpretation of data of hydrological / geo-technical surveys furnished by the Owner, carrying out fresh topographic survey of the rivers, NH, SH, Expressways, Railways, etc & developing new profile drawing for the crossing location, carrying out additional surveys required for collecting data relevant to design and construction of the crossing, performing all engineering & design calculations, preparation of all necessary construction drawings for approval of the Owner as per the provisions of contract document, preparation of detailed construction method statement and design analysis.,, -Taking delivery and transportation of Owner-supplied 3LPE coated pipes to the work site from designated stockpile location, inspection of the coated pipes visually and/or with holiday detector for defects, including arranging all necessary intermediate storage area required thereof till the pipes are installed in permanent position.,, -Complete site preparation including arranging of required land, setting up of fabrication yard, preparation of temporary arrangement for pipeline stringing, launching etc.,, -Carrying out repair of pipe defects, replacement in the case of non-repairable defects and repairing damages to pipe coating including defects/ damages occurring during transportation and handling.,, -Pre-construction surveys and collection of all necessary data.,, -String preparation including repair of pipe and pipe coating defects, welding, non-destructive testing of welds including 100% radiography (by X-ray), supply of films & all equipment and providing all facilities to Owner's representative(s) for examining radiographs, repair of defects in the welds and re-testing etc.,, -Coating of the field joints of the pipe string to be installed by HDD method with DIRAX heat shrink sleeves of M/s Raychem's make, DDXTM Directional Drilling Kit of M/s Canusa or of any other approved make used for HDD crossings.,, -Repair of all coating damages in the pipe section to be laid by HDD method by full encirclement sleeves using suitable cut sections of approved quality of heat shrink sleeves of M/s Raychem make, DDXTM Directional Drilling Kit of M/s Canusa or of any other approved make.,, "-Fabrication of 89mm OD steel conduit with an inner duct of 40mm OD HDPE pipe for OFC (wherever OFC has to be laid along with the carrier pipeline).",, "-Supply & fixing of easy to install heat shrinkable duct end caps for HDPE conduit for OFC (wherever OFC has to be laid along with the carrier pipeline).",, -Carrying out air cleaning, gauge pigging and pre-installation hydrostatic testing of the complete pipeline string, as per the specifications, including repair of defects and retesting etc.,, -Installation of the pipeline / pipeline and OFC conduit as a bundle crossing below the rivers, NH, SH, Expressways, Railways, etc by single horizontal directional drilling operation to the correct profile as per the approved drawings.,, -Carrying out post-installation hydrostatic testing of HDD pipe string (along with transition pipe section).,, -Carrying out post-installation coating survey as per approved procedure.,, -Restoration, clean-up and disposal of drilling fluid, waste and all other surplus materials etc.,, -Transportation of surplus Owner-supplied pipes to the designated stockpile location of the Owner.,, -Preparation of as-built drawings and other records etc.,, -All other works not specifically listed herein, but required as per specifications, drawings, provisions of the contract document, calculations and construction method statement, leading to successful completion of the works. Item 20.520
61 61 8.625" OD in Normal Soil Item 20.530 380 M
62 62 16" OD in Normal Soil Item 20.540 5380 M
63 63 Shallow HDD (upto 3 m Depth) for normal: Execution of road/other crossing by Shallow Horizontal Directional Drilling (HDD) technique including mobilization & de-mobilization at site(s), supply of all materials as per the `Scope of Supply' and all consumables, equipment, manpower & other resources and arranging the required land for site preparations and execution of, but not limited to, the following works in accordance with the specifications, drawings and as per all provisions of the contract document complete in all respect as per the instructions of the Engineer – in – charge /Site engineer.Taking delivery and transportation of Owner-supplied 3LPE coated pipes to the work site from designated stockpile location, inspection of the coated pipes visually and/or with holiday detector for defects, including arranging all necessary intermediate storage area required thereof till the pipes are installed in permanent position.Complete site preparation including arranging of required land, setting up of fabrication yard, preparation of temporary arrangement for pipeline stringing, launching etcCarrying out repair of pipe defects, replacement in the case of non-repairable defects and repairing damages to pipe coating including defects/ damages occurring during transportation and handling.String preparation including repair of pipe and pipe coating defects, welding, non-destructive testing of welds including 100% radiography (by X-ray), supply of films & all equipment and providing all facilities to Owner's representative(s) for examining radiographs, repair of defects in the welds and re-testing e tc.Carrying out pre-installation hydrostatic testing of the complete pipeline string, as per the specifications, including repair of defects and retesting etc.Coating of the field joints of the pipe string to be installed by shallow HDD method with DIRAX heat shrink sleeves of M/s Raychem's make, DDXTM Directional Drilling Kit of M/s Canusa or of any other approved make used for HDD crossings.Repair of all coating damages in the pipe section to be laid by shallow HDD method by full encirclement sleeves using suitable cut sections of approved quality of heat shrink sleeves of M/s Raychem make, DDXTM Directional Drilling Kit of M/s Canusa or of any other approved make.Fabrication of 89mm OD steel conduit with an inner duct of 40mm OD HDPE pipe for OFC (wherever OFC has to be laid along with the carrier pipeline).Supply & fixing of easy to install heat shrinkable duct end caps for HDPE conduit for OFC (wherever OFC has to be laid along with the carrier pipeline).Installation of the pipeline and OFC conduit as a bundle crossing below the Road/ other utility horizontally by shallow HDD operation to the correct profile as per the approved drawings in a pre-reamed hole of appropriate size.Carrying out post-installation coating survey as per approved procedure.Restoration, clean-up and disposal of drilling fluid, waste and all other surplus materials etc.All other works not specifically listed herein, but required as per specifications, drawings, provisions of the contract document, calculations and construction method statement, leading to successful completion of the works.Note :- The item to be operated under the specific instruction of Engineer in Charge Item 20.550
64 64 8.625" OD Item 20.560 30 M
65 65 16" OD Item 20.570 800 M
66 66 HDD Bundle Pulling: 16" OD + 10.75" OD with OFC duct: -Design, detailed engineering & installation of pipeline / pipelines & OFC conduit across rivers, NH, SH, Expressways, Railways, etc by HDD method.,, -Complete work for the crossing (between the limits, as indicated in the approved drawings) including mobilization & de-mobilization at site(s), supply of all materials as per the `Scope of Supply' and all consumables, equipment, manpower & other resources and arranging the required land for site preparations and execution of, but not limited to, the following works in accordance with the specifications, drawings and as per all provisions of the contract document and instructions of the Owner.,, -Interpretation of data of hydrological / geo-technical surveys furnished by the Owner, carrying out fresh topographic survey of the rivers, NH, SH, Expressways, Railways, etc & developing new profile drawing for the crossing location, carrying out additional surveys required for collecting data relevant to design and construction of the crossing, performing all engineering & design calculations, preparation of all necessary construction drawings for approval of the Owner as per the provisions of contract document, preparation of detailed construction method statement and design analysis.,, -Taking delivery and transportation of Owner-supplied 3LPE coated pipes to the work site from designated stockpile location, inspection of the coated pipes visually and/or with holiday detector for defects, including arranging all necessary intermediate storage area required thereof till the pipes are installed in permanent position.,, -Complete site preparation including arranging of required land, setting up of fabrication yard, preparation of temporary arrangement for pipeline stringing, launching etc.,, -Carrying out repair of pipe defects, replacement in the case of non-repairable defects and repairing damages to pipe coating including defects/ damages occurring during transportation and handling.,, -Pre-construction surveys and collection of all necessary data.,, -String preparation including repair of pipe and pipe coating defects, welding, non-destructive testing of welds including 100% radiography (by X-ray), supply of films & all equipment and providing all facilities to Owner's representative(s) for examining radiographs, repair of defects in the welds and re-testing etc.,, -Coating of the field joints of the pipe string to be installed by HDD method with DIRAX heat shrink sleeves of M/s Raychem's make, DDXTM Directional Drilling Kit of M/s Canusa or of any other approved make used for HDD crossings.,, -Repair of all coating damages in the pipe section to be laid by HDD method by full encirclement sleeves using suitable cut sections of approved quality of heat shrink sleeves of M/s Raychem make, DDXTM Directional Drilling Kit of M/s Canusa or of any other approved make.,, "-Fabrication of 89mm OD steel conduit with an inner duct of 40mm OD HDPE pipe for OFC (wherever OFC has to be laid along with the carrier pipeline).",, "-Supply & fixing of easy to install heat shrinkable duct end caps for HDPE conduit for OFC (wherever OFC has to be laid along with the carrier pipeline).",, -Carrying out air cleaning, gauge pigging and pre-installation hydrostatic testing of the complete pipeline string, as per the specifications, including repair of defects and retesting etc.,, -Installation of the pipeline / pipeline and OFC conduit as a bundle crossing below the rivers, NH, SH, Expressways, Railways, etc by single horizontal directional drilling operation to the correct profile as per the approved drawings.,, -Carrying out post-installation hydrostatic testing of HDD pipe string (along with transition pipe section).,, -Carrying out post-installation coating survey as per approved procedure.,, -Restoration, clean-up and disposal of drilling fluid, waste and all other surplus materials etc.,, -Transportation of surplus Owner-supplied pipes to the designated stockpile location of the Owner.,, -Preparation of as-built drawings and other records etc.,, -All other works not specifically listed herein, but required as per specifications, drawings, provisions of the contract document, calculations and construction method statement, leading to successful completion of the works.,, Item 20.580 200 M
67 67 Civil Works - ITC Item 00030
68 68 Earthwork in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including gettin g out and disposal of excavated earth up to 50m lead and lift up to 1.5 m, as directed by the Engineer-in-Charge : Item 30.10
69 69 All kinds of soil Item 30.20 1594 SQM
70 70 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in widt h as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by the Engineer-in-Charge. Item 30.30
71 71 All kinds of soil Item 30.40 7423.11 CUM
72 72 Extra for every additional lift of 1.5 m or part thereof in excavation/ banking excavated or stacked materials. Item 30.50
73 73 All kinds of soil Item 30.60 2593.07 CUM
74 74 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. Item 30.70 27.65 CUM
75 75 Filling the excavated earth to required grade, level & profile in low lying areas including watering, ramming, compacting at optimum moisture content to 90% of Proctor's density consolidation by rolling with 8 to 10 tonne power roller in layers not exceeding 20 c m thickness, including clearing the area by cutting of shrubs, bushes, grass, vegetation, debris etc. stacking and disposing out of plot area to an unobjectional area as directed by site Engineer complete in all respects inclusive of cost of all labour, materials , tools, tackles etc. as per drawings, specifications and direction of Site Engineer. Item 30.80 62.09 CUM
76 76 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : Item 30.90
77 77 1:2:4 (1 cement : 2 coarse sand (Zone-III) : 4 graded stone aggregate 20 mm nominal size) Item 30.100 99.64 CUM
78 78 1:3:6 (1 cement : 3 coarse sand (Zone-III) : 6 graded stone aggregate 20 mm nominal size) Item 30.110 19.73 CUM
79 79 1:4:8 (1 cement : 4 coarse sand (Zone-III) : 8 graded stone aggregate 40 mm nominal size) Item 30.120 71.97 CUM
80 80 Providing and laying cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 10 mm down size) mixed with approved brand of water proofing compound @ 1Kg/50 Kg bag of cement, in roof grading, coping, in bed concrete etc. at all heights & depths, including providing centering and shuttering, scaffolding, watering, curing, vibrating, etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of the Site Engineer. Item 30.130 2.16 CUM
81 81 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishi ng and reinforcement - All work up to plinth level : Item 30.140
82 82 1:1.5:3 (1 cement : 1.5 coarse sand (Zone-III): 3 graded stone aggregate 20 mm nominal size) Item 30.150 729.07 CUM
83 83 Centering and shuttering including strutting, propping etc. and removal of form for all heights : Item 30.160
84 84 Foundations, footings, bases of columns, etc. for mass concrete Item 30.170 4382.09 SQM
85 85 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto pli nth level. Item 30.180
86 86 Thermo-Mechanically Treated bars of grade Fe-500D or more Item 30.190 115178 KG
87 87 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in : Item 30.200
88 88 Cement mortar 1:6 (1 cement : 6 coarse sand) Item 30.210 32.98 CUM
89 89 Supplying, fabricating, erecting, placing and fixing in position M.S. structural works using rolled/ built up sections for truss, cl addings, bracings, purlins, supporting frames made of joists, tubes, pipes, channels, angles, plates, flats, bars etc. including cut ting to required size welding of joints, fixing anchor plates, including bolts, theading, nuts, washers, sleeves etc. including pre paration of detailed fabrication drawings & submission to the Engineer-in-Charge for approval before start of fabrication, supplying & applying painting with two coats of epoxy paint "EPILUX 155 High Build Enamel over a coat of "EPILUX 610" Primer of M/s BERGER or any other approved equivalent make as per manufacturer’s recommendation, complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge. (Excluding the cost of conc rete work). Item 30.220 22.23 TO
90 90 Providing and fixing first quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by the Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey ce ment slurry @ 3.3 Kg/sq.m., including pointing in white cement mixed with pigment of matching shade complete. Item 30.230 76.26 SQM
91 91 Supplying and laying flat brick soling in foundation trench, in floors, garages, sumps, etc., with bricks of class designation 50 la id to proper slope, level and grade etc. filling of the joints with sand etc. complete in all respects inclusive of cost of all labo ur, materials, tools, tackles etc. as per drawings, specifications and direction of the Site Engineer. Item 30.240 155.98 SQM
92 92 15 mm cement plaster on rough side of single or half brick wall of mix : Item 30.250
93 93 1:6 (1 cement : 6 coarse sand) Item 30.260 130.84 SQM
94 94 6 mm cement plaster of mix : Item 30.270
95 95 1:3 (1 cement : 3 fine sand) Item 30.280 1610 SQM
96 96 Neat cement punning. Item 30.290 54 SQM
97 97 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality : Item 30.300
98 98 Heavy Duty-20 : Item 30.310
99 99 Circular shape 560 mm internal diameter Item 30.320 4 EA
100 100 Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and lengt h below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the le ngth of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads [No tes: (1) Length of pile for payment shall be measured up to bottom of pile cap. (2) Truck Mounted rotary/ TMR/ Tubewell boring machi ne shall not be used] : Item 30.330
101 101 450 mm diameter piles Item 30.340 180 M
102 102 Supplying and using water proofing compound like CICO, PUDDLE or any other approved brand with Cement Plaster/ CC/ RCC complete in a ll respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of the Sit e Engineer. Item 30.350 12.55 KG
103 103 Supplying and providing non-shrinkable cement grout (SHRINKKOMP 20 or any other equivalent approved brand) for grouting holding down bolts in pocket holes for equipment foundation, including necessary surface preparation mixing of grout, curing as per manufacturer 's recommendation/ specification and direction of the Site Engineer. (Note: This item shall be operated under specific instruction o f the Engineer-in-Charge.) Item 30.360 26446 KG
104 104 Providing & installing 800 mm dia. stone columns of approximate depth 10 m from the bottom of trench (as per drawing) with well grad ed stone of 100 mm down size as per approved construction procedure including all labour, materials, transportation, consumables, e quipment, mobilisation and de-mobilisation of equipment, disposal of surplus materials, cost of all tests, stacking of stones for me asurement etc. complete in all respect as per specification, approved drawings & directions of the Engineer-in-Charge. Item 30.370 330.49 M
105 105 Supply and construction of sand pad foundation consisting of well graded coarse sand spread in layers not exceeding 200 mm in loose thickness over the area, so as to achieve relative density of 90% as indicated in drawing including all materials, labour, equipment (like vibratory roller, vibro-rammer & vibrators, etc.) transportation, tests, lead and lift etc. as per specifications and directi ons of the Site Engineer/ Engineer-in-Charge complete up to the satisfaction of Engineer-in-Charge. Item 30.380 5036.2 CUM
106 106 Supplying and laying of 75 mm thick Anticorrosive bituminous carpet under steel storage tanks (i.e. over compacted moorum) with scre ened dry coarse sand mixed with bitumen, dressing to the required slopes to form hard mass of specified compacted thickness using ro llers/ rammers all complete as per specifications and directions of the Site Engineer/ Engineer-in-Charge. Item 30.390 537.6 SQM
107 107 Supply and constructing a Crushed Stone Ring Beam below each tank shell, all-round, consisting of crushed stone of size 50 mm down l aid in two layers (each layer duly compacted to form a hard core ring), filling of voids/ pockets with medium to coarse sand, cappin g with a compacted sand layer all complete as per drawing, specifications and direction of the Site Engineer/ Engineer-in-Charge. Item 30.400 49.53 CUM
108 108 Civil Works - Non ITC Item 00040
109 109 Earthwork in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including gettin g out and disposal of excavated earth up to 50m lead and lift up to 1.5 m, as directed by the Engineer-in-Charge : Item 40.10
110 110 All kinds of soil Item 40.20 98322 SQM
111 111 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in widt h as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by the Engineer-in-Charge. Item 40.30
112 112 All kinds of soil Item 40.40 40147.9 CUM
113 113 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in d epth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Item 40.50 24399 CUM
114 114 Extra for every additional lift of 1.5 m or part thereof in excavation/ banking excavated or stacked materials. Item 40.60
115 115 All kinds of soil Item 40.70 1388.42 CUM
116 116 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. Item 40.80 2925.34 CUM
117 117 Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material. Item 40.90
118 118 Beyond 30 cm girth upto and including 60 cm girth Item 40.100 150 EA
119 119 Beyond 60 cm girth upto and including 120 cm girth Item 40.110 150 EA
120 120 Beyond 120 cm girth upto and including 240 cm girth Item 40.120 140 EA
121 121 Supplying chemical emulsion in sealed containers including delivery as specified. Item 40.130
122 122 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% Item 40.140 3475 L
123 123 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Item 40.150
124 124 Along the external wall where apron is not provided using chemical emulsion @ 7.5 litres/ sqm of the vertical surface of the substru cture to a depth of 300 mm including excavation channel along the wall & rodding etc. complete: Item 40.160
125 125 With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration Item 40.170 2896 M
126 126 "Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diamete r holes and plugging with cement mortar 1 : 2 (1 cement : 2 Coarse sand) to match the existing floor : " Item 40.180
127 127 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration Item 40.190 4913 SQM
128 128 Treatment of existing masonry using chemical emulsion @ 1 litre per hole at 300 mm interval including drilling holes at 45 degree an d plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole : Item 40.200
129 129 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration Item 40.210 2466 M
130 130 Filling the excavated earth to required grade, level & profile in low lying areas including watering, ramming, compacting at optimum moisture content to 90% of Proctor's density consolidation by rolling with 8 to 10 tonne power roller in layers not exceeding 20 c m thickness, including clearing the area by cutting of shrubs, bushes, grass, vegetation, debris etc. stacking and disposing out of plot area to an unobjectional area as directed by site Engineer complete in all respects inclusive of cost of all labour, materials , tools, tackles etc. as per drawings, specifications and direction of Site Engineer. Item 40.220 7088.9 CUM
131 131 Supplying and filling selected earth/ moorum (excluding black cotton soil) from Contractor's own borrow areas including royalty, wit h all leads and lifts in low laying areas and filling to required grade and level including watering, compacting at optimum moisture content to 90% of Proctor's density, consolidation and rolling with 8 to 10 tonne power roller in layers not exceeding 20 cm thic kness, complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of Site Engineer. Item 40.230 89985 CUM
132 132 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : Item 40.240
133 133 1:2:4 (1 cement : 2 coarse sand (Zone-III) : 4 graded stone aggregate 20 mm nominal size) Item 40.250 863.35 CUM
134 134 1:3:6 (1 cement : 3 coarse sand (Zone-III) : 6 graded stone aggregate 20 mm nominal size) Item 40.260 818.26 CUM
135 135 1:3:6 (1 cement : 3 coarse sand (Zone-III) : 6 graded stone aggregate 40 mm nominal size) Item 40.270 481 CUM
136 136 1:4:8 (1 cement : 4 coarse sand (Zone-III) : 8 graded stone aggregate 40 mm nominal size) Item 40.280 2055.02 CUM
137 137 Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's sp ecification. (Note: Unit "EA" shall mean "Per 50 Kg of Cement") Item 40.290 34 EA
138 138 Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal siz e) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. Item 40.300 1071 SQM
139 139 Providing and laying cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 10 mm down size) mixed with approved brand of water proofing compound @ 1Kg/50 Kg bag of cement, in roof grading, coping, in bed concrete etc. at all heights & depths, including providing centering and shuttering, scaffolding, watering, curing, vibrating, etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of the Site Engineer. Item 40.310 173.84 CUM
140 140 Providing and laying 40 mm thick CC 1:2:4 Damp Proof Course with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone ch ips 6 mm down size) laid to proper level & line including providing shuttering, applying two coats of bitumen applied @ 1.50 Kg/sqm and spreading an even layer of coarse sand over hot bitumen, etc. complete in all respects inclusive of cost of all labour, material s, tools, tackles etc. as per drawings, specifications and direction of the Site Engineer. Item 40.320 875 SQM
141 141 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishi ng and reinforcement - All work up to plinth level : Item 40.330
142 142 1:1.5:3 (1 cement : 1.5 coarse sand (Zone-III): 3 graded stone aggregate 20 mm nominal size) Item 40.340 7911.92 CUM
143 143 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) Item 40.350 87 CUM
144 144 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fille ts, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering , shuttering, finishing and reinforcement : Item 40.360
145 145 1:1.5:3 (1 cement : 1.5 coarse sand (Zone-III) : 3 graded stone aggregate 20 mm nominal size) Item 40.370 1810 CUM
146 146 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 Degree landings, balconies, shelves, chajjas , lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cos t of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (Zone-III) : 3 graded stone aggreg ate 20 mm nominal size) Item 40.380 2475 CUM
147 147 Providing and laying up to floor five level reinforced cement concrete in kerbs, steps and the like excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (Zone-III) : 3 graded stone aggregate 20 mm nomina l size) Item 40.390 52 CUM
148 148 Centering and shuttering including strutting, propping etc. and removal of form for all heights : Item 40.400
149 149 Foundations, footings, bases of columns, etc. for mass concrete Item 40.410 10871.9 SQM
150 150 Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. Item 40.420 19548 SQM
151 151 Suspended floors, roofs, landings, balconies and access platform Item 40.430 4720 SQM
152 152 Shelves (Cast in situ) Item 40.440 20 SQM
153 153 Lintels, beams, plinth beams, girders, bressumers and cantilevers Item 40.450 21211 SQM
154 154 Columns, Pillars, Piers, Abutments, Posts and Struts Item 40.460 17953 SQM
155 155 Stairs (excluding landings) except spiral-staircases Item 40.470 54 SQM
156 156 Weather shade, Chajjas, corbels, etc. including edges. Item 40.480 374 SQM
157 157 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto pli nth level. Item 40.490
158 158 Thermo-Mechanically Treated bars of grade Fe-500D or more Item 40.500 1.09967e+06 KG
159 159 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above pl inth level. Item 40.510
160 160 Thermo-Mechanically Treated bars of grade Fe-500 D or more Item 40.520 653237 KG
161 161 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in : Item 40.530
162 162 Cement mortar 1:6 (1 cement : 6 coarse sand) Item 40.540 1301.01 CUM
163 163 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to fl oor V level in all shapes and sizes in : Item 40.550
164 164 Cement mortar 1:6 (1 cement : 6 coarse sand) Item 40.560 4673 CUM
165 165 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in : Item 40.570
166 166 Cement mortar 1:3 (1 cement : 3 coarse sand) Item 40.580 1668 SQM
167 167 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level : Item 40.590
168 168 Cement mortar 1:3 (1 cement :3 coarse sand) Item 40.600 116 SQM
169 169 Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. Item 40.610 116 SQM
170 170 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanit y counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick ba se cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, inc luding rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. : Item 40.620
171 171 Granite of any colour and shade : Item 40.630
172 172 Area of slab up to 0.50 sqm Item 40.640 728 SQM
173 173 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar lo cation in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of c ut edges etc. complete. Item 40.650 12 EA
174 174 Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75 x 50 cm deep and 1.8 cm thick, fixed in ur inal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or w ith cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of the Engineer-i n-Charge and finished smooth. Item 40.660
175 175 Granite Stone of approved shade Item 40.670 2 SQM
176 176 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of t he building, all complete as per the architectural drawings, with 18 mm thick stone slab over 20 mm (average) thick base of cement m ortar 1:4 (1 cement : 4 coarse sand), laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge . : Item 40.680
177 177 Polished granite stone slab- Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. Item 40.690 596 SQM
178 178 Providing and fixing ISI marked flush door shutters conforming to IS:2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on bot h faces of shutters : Item 40.700
179 179 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws Item 40.710 2 SQM
180 180 Providing and fixing ISI marked flush door shutters conforming to IS:2202 (Part I) non-decorative type, core of block board construc tion with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face vene ers on both faces of shutters: Item 40.720
181 181 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws Item 40.730 44 SQM
182 182 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrange ments for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27. 5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS:4454 (Part-1) and M.S. top co ver of required thickness for rolling shutters. Item 40.740
183 183 80 x 1.25 mm M.S. laths with 1.25 mm thick top cover Item 40.750 365 SQM
184 184 80 x 1.20 mm M.S. laths with 1.20 mm thick top cover Item 40.760 18 SQM
185 185 Providing and fixing ball bearing for rolling shutters. Item 40.770 112 EA
186 186 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, to p lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. s heet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia. M.S. bar bent to sha pe as per standard drawing. Item 40.780 104 EA
187 187 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Item 40.790
188 188 Stainless Steel (Grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides. Item 40.800 22 SQM
189 189 Supplying, fabricating, erecting, placing and fixing in position M.S. structural works using rolled/ built up sections for truss, cl addings, bracings, purlins, supporting frames made of joists, tubes, pipes, channels, angles, plates, flats, bars etc. including cut ting to required size welding of joints, fixing anchor plates, including bolts, theading, nuts, washers, sleeves etc. including pre paration of detailed fabrication drawings & submission to the Engineer-in-Charge for approval before start of fabrication, supplying & applying painting with two coats of epoxy paint "EPILUX 155 High Build Enamel over a coat of "EPILUX 610" Primer of M/s BERGER or any other approved equivalent make as per manufacturer’s recommendation, complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge. (Excluding the cost of conc rete work). Item 40.810 137.76 TO
190 190 Supplying, fitting and fixing hot dip galvinised barbed line wire through holes in fencing posts (already made in the body of the po st), tightening and fixing the wire in tight condition with straining bolts (straining bolts at end post) including the cost of cutt ing and lapping joints, making holes, straining bolts, galvanised staples, binding wires etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of the Engineer-in-Charge. Item 40.820 23560 M
191 191 Supplying & fixing welded wire mesh door made from steel wire fabric of rectangular mesh 75 x 25 mm size, weight not less than 7.75 Kg/sqm fixed on angle iron frame by welding, fixing of holdfast, hinges, door handles, tower bolts, aldrops (2 Nos.), painting with two coats of synthetic enamel paint of over a coat of red oxide zinc chrome primer, excluding frame etc. complete in all respects i nclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Cha rge. (Note: Angle iron frame shall be paid separately). Item 40.830 55 SQM
192 192 Supplying and placing in position 5.0 mm thick steel chequered plates over cable ducts, valve pits etc. including provision for lift ing arrangements complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifica tions and directions of the Engineer-in-Charge. Item 40.840 1572 SQM
193 193 Supplying & fixing Pigeon Protection net of mesh 15 mm x 15 mm & Gauge SW14 in sheds including specials required for bolting with ti e members of truss, painted with two coats of synthetic enamel paint of over a coat of red oxide zinc chrome primer complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of the Engine er-in-Charge. Item 40.850 360 SQM
194 194 Supplying, fitting and fixing punched tape concertina spiral coil of 50 turns per coil having core wire of 2.6 mm diameter made of h igh carbon spring steel of high tensile strength as per IS:4454 (Part-I, Grade-II) having minimum galvanising coating thickness equi valent to 230 grams per square metre and low carbon steel strip of 0.5 mm thickness having a series of barbes punched all along the length on both sides of the strip at regular interval as per IS:513, DD quality having minimum galvanising coating thickness of 12 m icrons. Hardness of tape should be between 137-180 VPN (Victor Penetration Number). The coil should be clipped sufficiently at regul ar intervals. The coil should not be stretched for more than 6.0 m length and the minimum diameter of the coil in the closed conditi on should not be less than 600 mm complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per dr awings, specifications and directions of the Engineer-in-Charge. Item 40.860 5890 M
195 195 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coa rse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement har dener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. Item 40.870 360 SQM
196 196 Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting m ortar bedding, and joints filled with acid and/or alkali resisting cement as per IS:4457, complete as per the direction of Engineer- in-Charge. Item 40.880
197 197 In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) Item 40.890
198 198 Acid and alkali resistant tile Item 40.900 486 SQM
199 199 In dado/ skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) Item 40.910
200 200 Acid and alkali resistant tile Item 40.920 232 SQM
201 201 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match t he shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : Item 40.930
202 202 25 mm thick Item 40.940 2031 SQM
203 203 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cemen t: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and poli shing complete. Item 40.950 707 SQM
204 204 Providing and fixing first quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by the Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey ce ment slurry @ 3.3 Kg/sq.m., including pointing in white cement mixed with pigment of matching shade complete. Item 40.960 907.74 SQM
205 205 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of first quality conforming to IS:15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 Kg/sq.m. including pointing the joints with white cement and mat ching pigment, etc. complete. Item 40.970 331 SQM
206 206 Providing and fixing first quality ceramic glazed floor tiles conforming to IS:15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirt ing, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slu rry @ 3.3 Kg/sq.m. including pointing in white cement mixed with pigment of matching shade complete. Item 40.980 90 SQM
207 207 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 ce ment : 4 coarse sand), jointing with grey cement slurry @ 3.3 Kg/sq.m. including grouting the joints with white cement and matching pigments etc., complete. Item 40.990
208 208 Size of Tile 500x500 mm Item 40.1000 216 SQM
209 209 Size of Tile 600x600 mm Item 40.1010 415 SQM
210 210 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to IS:15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of c ement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 Kg/sq.m. including grouting the joint with white cement & matching pigments etc. complete. Item 40.1020
211 211 Size of Tile 500x500 mm Item 40.1030 31 SQM
212 212 Size of Tile 600x600 mm Item 40.1040 115 SQM
213 213 Providing and fixing removable raised/ false access flooring with system (Unitile Solid Feel (USF) 800 or equivalent) and its compon ents of approved make for different plenum height with possible height adjustment up to 50 mm, comprising of modular load bearing fl oor panels supported on G.I. rectangular stinger frame work and G.I. Pedestal etc. all complete, as per the architectural drawings, as specified and as directed by Engineer-in-charge consisting of: (A) Providing at required spacing to form modular framework, pedes tals made out of G.I. tube of thickness minimum 2 mm and 25 mm outer diameter, fully welded on to the G.I. Base plate of size 100mm x 100mm x 3mm at the bottom of the pedestal tube, G.I. pedestal head of size 75 mm x 75 mm x 3.5 mm welded with G.I. fully threaded stud 16 mm outer diameter with two G.I. Check nuts screwed on the stud for level adjustment up to 50 mm, locking and stabilizing the pedestal head in position at the required level. The pedestals shall be fixed to the sub-floor (base) through base plate using epox y based adhesive of approved make or the machine screw with rawl plug. (B) Stringers system in all steel construction hot dipped gal vanized of rectangular size 570x20x30x0.80 mm thick having holes at both ends for securing the stringers on to the pedestal head usi ng fully threaded screws ensuring maximum lateral stability in all directions, the grid formed by the pedestal and stringer assembly shall receive the floor panel, this system shall provide adequate solid, rigid support for access floor panel. The system shall pro vide a minimum clear uninterrupted clearance between the bottom of the floor for electrical conduits and wiring etc. all complete as per the architectural drawings, as specified and as directed by the Engineer-in-Charge. (C) Providing and fixing Access Floor panel of 600x600x32 mm medium grade Filled Steel anti static high pressure Lamination of 800H grade (FS800H). Access Floor panel shall be steel welded construction with an enclosed bottom pan with uniform pattern of 64 hemispherical cones. The top and bottom plates of Steel Gauges: top 0.6 mm and bottom 0.7 mm fused spot welded together (minimum 64 welds in each dome and 20 welds along each flange) . The panel should be corrosion resistant epoxy coated for lifetime rust protection and cavity formed by the top and bottom plate is filled with Pyrogrip non-combustible Portland cementitious core mixed with lightweight foaming compound. The access floor shall be factory finished with Anti-static High Pressure laminate with Non Warp technology up to 1 mm thickness for superior adhesion and Sur face flatness within 0.75 mm.The panel is to withstand a Concentrated Load of 363 Kg applied on area 25 mm x 25 mm without collapse in the centre of the panel which is placed on four steel blocks. The panel will withstand and Uniformly Distributed Load (UDL) minim um 1250 Kg/sq.m. and, an impact load of 50 Kg all complete as per the approved manufacturers specification and as per the direction of the Engineer-in-Charge. All specification must be printed on the side of the panel to ensure the quality of the product. Item 40.1050
214 214 450 mm Finished Floor Height (FFH) Item 40.1060 86 SQM
215 215 Supplying and laying flat brick soling in foundation trench, in floors, garages, sumps, etc., with bricks of class designation 50 la id to proper slope, level and grade etc. filling of the joints with sand etc. complete in all respects inclusive of cost of all labo ur, materials, tools, tackles etc. as per drawings, specifications and direction of the Site Engineer. Item 40.1070 15034 SQM
216 216 Providing and laying cement concrete flooring 25 mm thick of mix 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregates 12.5 mm nominal thickness), laid monolithically over base of concrete in panels at all locations and heights including treads of steps, nos ing, landing slab etc. and finished with a floating coat of neat cement @ 2.20 Kg of cement per sqm of flooring, supplying and fixin g 1.5 mm thick aluminium strips for full depth, chequering in floor finish if required, rounding, sloping, curing, finishing, prepar ation of slab, steps, etc., complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings , specifications and directions of the Engineer-in-Charge. (Payment for base concrete shall be made under relevant item). Item 40.1080 285 SQM
217 217 Providing and fixing 2 mm thick P.V.C. (BHOR or equivalent make) sheet/ tile flooring on a smooth and damp proof base using rubber b ased adhesives including rolling with light wooden roller weighing about 5 Kg, all complete including cost of preparation of subgra de, damp proof course consisting of 30 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm n ominal size) as directed by the Engineer-in-Charge. Item 40.1090 161 SQM
218 218 Providing and laying 52 mm thick cement concrete flooring with metallic hardner, under layer of 37 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer of 15 mm thick metallic concrete hardner consis ting of mix 1:2 (1 cement : 2 stone aggregate 6 mm nominal size) by volume with which metallic hardening compound such as IRONITE NO . 1 of IRONITE CO. OF INDIA LTD. or aproved equivalent mixed in the ratio 4:1 (4 parts of cement : 1 part of metallic floor hardenin g compound of approval quality) by weight, inclusive of cost of finishing, labour, material, equipment, etc. as per specifications a nd directions of the Engineer-in-Charge. Item 40.1100 776 SQM
219 219 Providing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat : Item 40.1110
220 220 With common burnt clay F.P.S. (Non Modular) brick tiles of Class Designation 10 Item 40.1120 82 SQM
221 221 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including fini shing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : Item 40.1130
222 222 In 75x75 mm deep chase Item 40.1140 1498 M
223 223 Making Khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggr egate of 20 mm nominal size) over P.V.C. sheet 1 m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse s and) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. Item 40.1150 128 EA
224 224 Providing and fixing 100 mm diameter and 60 cm long rainwater spout in cement mortar 1:4 (1 cement : 4 fine sand) : Item 40.1160
225 225 Stoneware Spout Item 40.1170 4 EA
226 226 Providing and fixing on wall face Unplasticised Rigid PVC (UPVC) rainwater pipes conforming to IS:13592 Type-A, including jointing w ith seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion: (i) Single socketed pipes : Item 40.1180
227 227 110 mm diameter Item 40.1190 2288 M
228 228 Providing and fixing on wall face Unplasticised-PVC (UPVC) moulded fittings/ accessories for Un-plasticised Rigid PVC rainwater pipe s conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion : Item 40.1200
229 229 Coupler : Item 40.1210
230 230 110 mm Item 40.1220 246 EA
231 231 Single Push-fit Coupler : Item 40.1230
232 232 110 mm Item 40.1240 246 EA
233 233 Bend 87.5 Degrees : Item 40.1250
234 234 110 mm Bend Item 40.1260 230 EA
235 235 Shoe (Plain) : Item 40.1270
236 236 110 mm Shoe Item 40.1280 230 EA
237 237 Providing and fixing Unplasticised-PVC (UPVC) pipe clips of approved design to unplasticised-PVC rainwater pipes by means of 50x50x5 0 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 c ement : 4 coarse sand) and making good the wall etc. complete. Item 40.1290
238 238 110 mm Item 40.1300 48 EA
239 239 Designing, providing, fabricating and fixing profiled sheeting 730-1020 mm cover width, 28-30 mm crests @ 186-333 mm centre to centr e, manufactured out of 0.45 mm BMT (Base Metal Thickness) Hi-Tensile Steel (Minimum yield strength of 550 MPa) coated with hot dip m etalic galvalume/ zincalume coating AZ-150 or equivalent as per AS:1397 and super polyster XRW quality paint coat as per AS/ NZS2728 (Category-3) of approved colour for roofing, cladding, gutters, rainwater pipes, spouts etc. The total mass of the coating on both sides shall be 150 gms/sqm (Zinc 45%/ Aluminium 55%). The total paint coat thickness shall be 35 microns, comprising of 20 microns e xterior coat of super polyster XRW on top surface and 5 micron super polyester on back surface over 5 micron primer coats on both su rfaces including side and end laps. The sheets shall have wide pans with 2-3 stiffening ribs for effective water shedding and specia l male/ female ends with full return legs on side laps for purlins support and anti-capilary flute in side lap. The sheets shall be fixed using polymer coated hot dip galvanised hex head self drilling fasteners as per AS:3566 (Class-3) on each crest of sheets for connection with purlins and polymer coated hot dipped stitching fasteners at 300 mm c/c on all sides and end laps, etc. Approved sea ling tapes shall be used on side laps and end laps of sheets and closer to be provided at the last end of sheet. The measurement sha ll be based on per unit of finished/ laid area. Item to include curved sheets also wherever required. The Contractor shall give mini mum 10 year guarantee for the sheets against deterioration, disintegration, loss of lustre, variation in colour, etc. and leakages a cross laps, fasteners etc. The Contractor is to submit design and shop drawing for approval on the sheet profile, design and details before installation. Item 40.1310
240 240 Roof, side cladding, gable end cladding, gutters, rainwater pipes/ spouts etc. (Note: The area of sheet coverings shall be measured on the flat surface i.e. without allowance for laps and ribs). Item 40.1320 1288 SQM
241 241 Providing, supplying, erecting and fixing in position 3 mm thick polycarbonate sheets of approved texture and colour for roof lighti ng. Sheets to be profiled to match metal sheets described in respective item above. Cost to include jointing, sealing with Butyl adh esives and tapes as per manufacturers specifications and all labour, tools, plants, temporary works, etc. all complete. Item 40.1330 194 SQM
242 242 Supplying, erecting and fixing in position 600 mm wide Colour Bond Ridge Cap and corner flushing rolled from 0.5 mm TCT BHP Zincalum e AZ-150 High Tensile Steel (550 MPa Yield Strength) including fixing to sheets stiched by (4.8 mm x 16 mm) Hex Head stitch screws, with metal bonded EPDM washers all complete as per specifications and directtions of the Engineer-in-Charge. Item 40.1340 154 M
243 243 Providing and fixing LUXALON 75C & 225C un-perforated Aluminium panel coloured ceiling manufactured by M/s. HUNTER DOUGLAS INDIA or any other approved equivalent brand, each panel consisting of 75/225 mm wide x 15.5 mm deep and 0.5 mm thick with bevel edged panel made from enamelled corrosion resistance aluminium alloy AA-5050 (Al.Mg), each panel to abut each other with a narrow 'V' groove, cl ipping with a baked enamelled aluminium panel carrier of 32 mm wide x 39 mm deep x 0.95 mm thick in standard length of 5 metres made of double baked enamelled aluminium alloy AA-5050 (Al.Mg) black with cutouts to hold the panels in a module of 75 mm closed at a di stance of 1.25 metre, each panel carrier suspended by means of G.I. suspension rod 4 mm diameter and a galvanised supsension spring clip at a distance of 1.7 metre centre to centre, making openings for light fittings etc. with suitable peimeter framing all complet e as per manufacturer's recommendation and directions of the Engineer-in-Charge. (Note: Measurement shall be made wall to wall witho ut any deduction for openings, for payment purpose). Item 40.1350 393 SQM
244 244 Extra over above item for providing perforated panels with non-woven tissue glued to panels. Item 40.1360 393 SQM
245 245 Providing and laying 20 mm thick pre-cast cement concrete tiles of mix 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregates 1 2.5 mm nominal thickness) grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% integral water proofing compund by w eight of cement over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) finished neat etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge. Item 40.1370 4291 SQM
246 246 15 mm cement plaster on the rough side of single or half brick wall of mix : Item 40.1380
247 247 1:6 (1 cement : 6 fine sand) Item 40.1390 19316 SQM
248 248 15 mm cement plaster on rough side of single or half brick wall of mix : Item 40.1400
249 249 1:6 (1 cement : 6 coarse sand) Item 40.1410 35304.2 SQM
250 250 6 mm cement plaster of mix : Item 40.1420
251 251 1:3 (1 cement : 3 fine sand) Item 40.1430 48898 SQM
252 252 Neat cement punning. Item 40.1440 2 SQM
253 253 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Item 40.1450
254 254 Water thinnable cement primer Item 40.1460 23363 SQM
255 255 Finishing walls with water proofing cement paint of required shade : Item 40.1470
256 256 New work (Two or more coats applied @ 3.84 Kg/10 sqm) Item 40.1480 49397 SQM
257 257 Finishing walls with textured exterior paint of required shade : Item 40.1490
258 258 New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm Item 40.1500 20207 SQM
259 259 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Item 40.1510
260 260 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. Item 40.1520 100 SQM
261 261 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wa ll surface to prepare the surface even and smooth complete. Item 40.1530 23363 SQM
262 262 Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approv ed brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Item 40.1540
263 263 Two coats Item 40.1550 18325 SQM
264 264 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved bra nd and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Item 40.1560
265 265 Two coats Item 40.1570 2176 SQM
266 266 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 gra ms/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Item 40.1580
267 267 Two coats Item 40.1590 2896 SQM
268 268 Painting with synthetic enamel paint, having VOC (Volatile Organic Compound) content less than 150 grams/ litre, of approved brand a nd manufacture, including applying additional coats wherever required to achieve even shade and colour. Item 40.1600
269 269 Two coats Item 40.1610 285 SQM
270 270 Providing grooves of uniform size 12x12 mm and up to 15x15 mm in plaster as per approved pattern using wooden battens, nail to the u nder layer including removal of wooden battens repair to the edges of panels and finishing the groove complete as per directions of the Engineer-in-Charge. Item 40.1620 5460 M
271 271 Providing & fixing galvanized chicken wire net 20 Gauge, 20 mm mesh size in plastering work at the junction of RCC Columns/ Beams & brickwork as directed by the Engineer-in-Charge. Item 40.1630 7161 SQM
272 272 Providing and laying Burnt Terracota Tiles 12 mm thick for facia, over walls, sloping RCC Roofs etc. at all levels and locations lai d over and including a backing coat of 15 mm thick cement mortar (1 cement : 3 sand) and joints filled with coloured cement of same colour as tiles complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per specifications and d irections of the Engineer-in-Charge. Item 40.1640 987 SQM
273 273 Providing and fixing 12 mm thick Elevational Brick Tiles for facia, vertical face of walls, etc. at all levels and locations laid ov er and including a backing coat of 15 mm thick cement mortar (1 cement : 3 sand) and joints filled with coloured cement of same colo ur as tiles complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per specification and direct ions of the Engineer-in-Charge. Item 40.1650 733 SQM
274 274 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of t he Engineer-in-Charge. [Notes: (1) Dismantling shall be allowed during day shift only & prior permission for the same shall be obtai ned. (2) Providing of necessary covers/ barricades around the work area shall be done prior to dismantling operations.] Item 40.1660
275 275 Nominal concrete 1:3:6 or richer mix (including equivalent design mix) Item 40.1670 64 CUM
276 276 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of the Engineer-in-Charge. [Notes: (1) Dismantling shall be allowed during day shift only & prior p ermission for the same shall be obtained. (2) Providing of necessary covers/ barricades around the work area shall be done prior to dismantling operations. (3) Cutting of all reinforcement shall be done using hack saw or chiesel or any other method as approved by the Engineer-in-Charge.] Item 40.1680 64 CUM
277 277 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable materi al within 50 metres lead as per direction of the Engineer-in-Charge. [Notes: (1) Dismantling shall be allowed during day shift only & prior permission for the same shall be obtained. (2) Providing of necessary covers/ barricades around the work area shall be done prior to dismantling operations.] Item 40.1690
278 278 In cement mortar Item 40.1700 64 CUM
279 279 Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge. [Notes: (1) Dismantling shall be allowed during day shift only & prior permission for the same shall be obtained. (2) Providing of necessary covers/ barricades around the work area shall be done prior to dismantling operations . (3) Cutting of steel shall be done using hack saw or chiesel or any other method as approved by the Engineer-in-Charge.] Item 40.1710 440 KG
280 280 Dismantling of flexible pavement (bituminous courses) by mechanical means and disposal of dismantled material up to a lead of 1 kilo metre, as per direction of the Engineer-in-Charge. Item 40.1720 124 CUM
281 281 Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, tr ansporting, unloading to approved municipal dumping ground or as approved by the Engineer-in-Charge, beyond 50 m initial lead, for a ll leads including all lifts involved. Item 40.1730 244 CUM
282 282 Preparation and consolidation of sub-grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the s ub grade and disposal of surplus earth with lead up to 50 metres. Item 40.1740 15722 SQM
283 283 Providing and applying tack coat using bitumen emulsion conforming to IS:8887, using emulsion pressure distributer including prepari ng the surface & cleaning with mechanical broom.: Item 40.1750
284 284 With medium setting bitumen emulsion : Item 40.1760
285 285 On W.B.M/ W.M.M. @ 0.4 Kg/sqm Item 40.1770 4550 SQM
286 286 Providing and laying Bitumen Penetration Macadam with hard stone aggregate of quality, size and grading as specified, with bitumen o f suitable penetration grade, including required key aggregate as specified, spreading coarse aggregate with the help of self propel led/ tipper tail mounted aggregate spreader and applying bitumen by a pressure distributor and then spreading key aggregate with the help of aggregate spreader complete, including consolidation with road roller of minimum 8 to 10 tonne capacity to achieve specifie d values of compaction and surface accuracy : Item 40.1780
287 287 For 50 mm compacted thickness using coarse aggregate of size 50-20 mm graded @ 0.60 cum per 10 sqm key aggregate of size 12.5 mm gra ded @ 0.15 cum per 10 sqm with paving asphalt grade VG-10 @ 50 kg/10 sqm. Item 40.1790 4550 SQM
288 288 Providing and laying seal coat over prepared surface of road with bitumen heated in bitumen boiler fitted with the spray set sprayin g using 98 kg of bitumen of grade VG-10 and blinding surface with 0.90 cum of stone aggregate of 6.7 mm size (Passing 11.2 mm sieve and retained on 2.36 mm sieve) per 100 sqm of road surface, including rolling and finishing with power road roller all complete. (No te: This item to be operated only with the prior approval of the Engineer-in-Charge.) Item 40.1800 4550 SQM
289 289 Providing and laying design mix cement concrete of M-30 grade in roads/ taxi tracks/ runways, using cement content as per design mix , using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design c riteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by usin g needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per di rection of the Engineer-in-Charge. [Notes: (1) Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separate ly. (2) Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separa tely]. Item 40.1810
290 290 Cement concrete prepared with batch mixing machine Item 40.1820 1546 CUM
291 291 Providing and fixing in position pre-moulded joint filler in expansion joints. (Note: Unit "CM" shall mean "PER CENTIMETRE DEPTH PER CENTIMETRE WIDTH PER METRE LENGTH"). Item 40.1830 20033 CM
292 292 Providing and laying in position bitumen hot sealing compound for expansion joints etc. : Item 40.1840
293 293 Using Grade 'A' sealing compound. (Note: Unit "CM" shall mean "PER CENTIMETRE DEPTH PER CENTIMETRE WIDTH PER METRE LENGTH"). Item 40.1850 2577 CM
294 294 Painting road surface marking with adequate nos of coats to give uniform finish with ready mixed road marking paint conforming to IS :164, on bituminous surface in white/ yellow shade, including cleaning the surface of all dirt, scales, oil, grease and foreign mate rial etc. complete.: Item 40.1860
295 295 New work (Two or more coats) Item 40.1870 273 SQM
296 296 Providing and applying 2.5 mm thick road marking strips (retro-reflective) of specified shade/ colour using hot thermoplastic materi al by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank hea ter and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the ro ad surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of the Engineer-in-Charge and accorda nce with applicable specifications. Item 40.1880 434 SQM
297 297 Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wi re or nuts, bolts and washers as required complete as per the direction of the Engineer-in-Charge. Item 40.1890
298 298 Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade. Item 40.1900 696 SQM
299 299 Construction of granular sub-base by providing close graded material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thicknes s with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per s pecifications and directions of the Engineer-in-Charge. Item 40.1910
300 300 With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 Item 40.1920 1714 CUM
301 301 Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specific ation including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfin isher in sub-base/ base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of the Engineer-in-Charge. Item 40.1930 1138 CUM
302 302 Providing and laying factory made chamfered edge Cement Concrete paver blocks In foot path, park & lawns driveway or light & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/laying of inter locking paver blocks into th e sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturer's specifications & direction o f the Engineer-in-Charge. Item 40.1940
303 303 60mm thick Cement Concrete paver block of M-35 grade with approved colour, design & pattern. Item 40.1950 9793 SQM
304 304 Supplying & fixing in position pre-cast cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate) kerb stone of size 450 mm high, 150 mm average thick & 600 mm long, each stone joined with 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) over a base of cement mortar, including excavation, bed concrete 300 wide & 100 thick in cement concrete 1:3:6 concrete, painting of expos d surfaces etc. complete in all respects inclusive of cost of all materials, labour, tools, tackles etc. as per specifications and d irection of Site Engineer. Item 40.1960 7600 M
305 305 Supplying and fixing Road Hump of minimum size 350 mm width x 50 mm thick made of Carbon Black mixed Rubber with Additive of LDPE fo r reinforcement & UV resistant colouring agent of black & yellow colour with 4 reflective glass beads, of weight not less than 16 Kg /metre, and capacity to withstand minimum 35 tonne weight (moving vehicle load) including cleaning the road surface of all dirt, sca les, oil, grease and foreign material etc. and fixing the hump on the Road top as per manufactures specifications with necessary fas teners complete in all respects inclusive of cost of all labour, materials, fasteners, tools, tackles etc. as per specification and direction of the Engineer-in-Charge. Item 40.1970 370 M
306 306 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : Item 40.1980
307 307 W.C. pan with ISI marked white solid plastic seat and lid. Item 40.1990 26 EA
308 308 Providing and fixing white vitreous china pedestal type water closet (European type) (Ref. Make: HINDWARE, Model: Cat No.-20058 or e quivalent approved) with seat and lid, 10 litre low level white vitreous china dual flushing cistern (Ref. Make: HINDWARE, Model: Ca t No.-21028 or equivalent approved) & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with spe cials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and bracket s, cutting and making good the walls and floors wherever required : Item 40.2000
309 309 W.C. pan with ISI marked white solid plastic seat and lid Item 40.2010 4 EA
310 310 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I cl amps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Item 40.2020
311 311 One urinal basin with 5 litre white P.V.C. automatic flushing cistern Item 40.2030 27 EA
312 312 Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern Item 40.2040 2 EA
313 313 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, includ ing painting of fittings and brackets, cutting and making good the walls wherever require : Item 40.2050
314 314 White Vitreous China Wash basin size 550x400 mm (Ref. Make: HINDWARE, Model: Cat No.-10010 or equivalent approved) with a pair of 15 mm C.P. brass pillar taps Item 40.2060 5 EA
315 315 White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap Item 40.2070 51 EA
316 316 Providing and fixing 8 mm dia C.P./ S.S. Jet with flexible tube up to 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by the Engineer-in-Charge. Item 40.2080 4 EA
317 317 Providing and fixing C.P. Brass 32 mm size Bottle Trap of approved quality & make and as per the direction of the Engineer-in-Charge . Item 40.2090 10 EA
318 318 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete : Item 40.2100
319 319 Semi Rigid Pipe : Item 40.2110
320 320 32 mm diameter Item 40.2120 10 EA
321 321 Flexible Pipe : Item 40.2130
322 322 32 mm diameter Item 40.2140 52 EA
323 323 Providing and fixing 100 mm sand cast Iron grating for gully trap. Item 40.2150 16 EA
324 324 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board grou nd fixed to wooden cleats with C.P. brass screws and washers complete. Item 40.2160 52 EA
325 325 Providing and fixing toilet paper holder : Item 40.2170
326 326 C.P. Brass (Ref. Make: JAQUAR, Model: Cat. No.-1151 or approved equivalent). Item 40.2180 31 EA
327 327 Providing and fixing soil, waste and vent pipes : Item 40.2190
328 328 100 mm diameter Item 40.2200
329 329 Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS:3989 Item 40.2210 189 M
330 330 Providing and fixing plain bend of required degree : Item 40.2220
331 331 100 mm diameter : Item 40.2230
332 332 Sand Cast Iron S&S as per IS:3989 Item 40.2240 18 EA
333 333 Providing and fixing double equal plain junction of required degree : Item 40.2250
334 334 100x100x100x100 mm : Item 40.2260
335 335 Sand Cast Iron S&S as per IS:3989 Item 40.2270 6 EA
336 336 Providing and fixing single equal plain junction of required degree : Item 40.2280
337 337 100x100x100x100 mm : Item 40.2290
338 338 Sand Cast Iron S&S as per IS:3989 Item 40.2300 6 EA
339 339 Providing and fixing collar : Item 40.2310
340 340 100 mm : Item 40.2320
341 341 Sand Cast Iron S&S as per IS:3989 Item 40.2330 6 EA
342 342 Providing and fixing shielded coupling for Hubless centrifugally cast iron pipe : Item 40.2340
343 343 100 mm diameter : Item 40.2350
344 344 SS-304 grade coupling with EPDM rubber Item 40.2360 24 EA
345 345 Providing and fixing M.S. stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter : Item 40.2370
346 346 100 mm Item 40.2380 30 EA
347 347 Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : Item 40.2390
348 348 100 mm diameter pipe Item 40.2400 58 M
349 349 Providing and fixing glazed vitreous China Oval wash basin of 560x410 mm size (Ref. Make: HINDWARE, Model: Cat No.-10017 or equivale nt approved) with M.S. or C.I. brackets painted white, C.P. brass chain with rubber plug, 32mm C.P. brass waste coupling of standard pattern, 32mm C.P. brass bottle trap and union, 32mm diameter C.P. pipes to wall flange etc. including cutting and making good the walls & floors wherever required, etc. complete in all respects inclusive of cost of all required fittings, fixtures, materials, lab our, tools, tackles etc. as per specifications and directions of the Engineer-in-Charge. Item 40.2410
350 350 White Colour Item 40.2420 6 EA
351 351 Providing and fixing Polyethelene-Aluminium-Polyethelene (PE-AL-PE) Composite Pressure Pipes conforming to IS-15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 metre spacing. This includes testing of joints complete as per direction of the Engi neer-in-Charge. Item 40.2430
352 352 2025 (25 mm OD) pipe Item 40.2440 128 M
353 353 2532 (32 mm OD) pipe Item 40.2450 128 M
354 354 (Exposed on Wall)Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-In-Charge. Item 40.2460
355 355 15 mm nominal outer dia pipes Item 40.2470 128 M
356 356 20 mm nominal outer dia pipes Item 40.2480 144 M
357 357 25 mm nominal outer dia pipes Item 40.2490 12 M
358 358 (Concealed Work)Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of the Engineer-In-Charge. Item 40.2500
359 359 15 mm nominal outer dia pipes Item 40.2510 386 M
360 360 20 mm nominal outer dia pipes Item 40.2520 451 M
361 361 25 mm nominal outer dia pipes Item 40.2530 12 M
362 362 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refil ling & testing of joints complete as per direction of the Engineer-In-Charge. Item 40.2540
363 363 20 mm nominal outer dia pipes Item 40.2550 60 M
364 364 32 mm nominal outer dia pipes Item 40.2560 11 M
365 365 40 mm nominal outer dia pipes Item 40.2570 212 M
366 366 50 mm nominal outer dia pipes Item 40.2580 250 M
367 367 75 mm nominal outer dia pipes Item 40.2590 2938 M
368 368 100 mm nominal outer dia pipes Item 40.2600 180 M
369 369 Fixing water meter and stop cock in G.I. pipe line including cutting and threading the pipe and making long screws etc. complete (co st of water meter and stop cock to be paid separately). Item 40.2610 26 EA
370 370 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : Item 40.2620
371 371 25 mm nominal bore Item 40.2630 52 EA
372 372 32 mm nominal bore Item 40.2640 51 EA
373 373 40 mm nominal bore Item 40.2650 2 EA
374 374 50 mm nominal bore Item 40.2660 4 EA
375 375 Providing and fixing ball valve (brass) of approved quality, high or low pressure, with plastic floats complete : Item 40.2670
376 376 20 mm nominal bore Item 40.2680 10 EA
377 377 Providing and fixing Un-plasticised PVC (UPVC) connection pipe with brass unions: Item 40.2690
378 378 45 cm length : Item 40.2700
379 379 20 mm nominal bore Item 40.2710 34 EA
380 380 Providing and placing on terrace (at all floor levels) polyethylene water storage tank (Ref. Make: SINTEX or approved equivalent), I S:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but with out fittings and the base support for tank. Item 40.2720
381 381 Circular Tank Item 40.2730 2500 L
382 382 Rectangular Tank Item 40.2740 12750 L
383 383 Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms . Item 40.2750
384 384 15 mm nominal bore Item 40.2760 51 EA
385 385 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS-8931 : Item 40.2770
386 386 15 mm nominal bore Item 40.2780 4 EA
387 387 Providing and fixing 15mm diameter C.P. brass tap as per following with C.P. brass flange including cutting & making good the walls wherever required, etc. complete in all respects inclusive of cost of all materials, labour, tools, tackles etc. as per specificatio ns and directions of the Engineer-in-Charge. : Item 40.2790
388 388 Bib Cock (Ref. Make: JAQUAR, Model: Cat. No. 0021 or approved equivelent) Item 40.2800 112 EA
389 389 Bib Cock (Ref. Make: JAQUAR, Model: Cat. No. 0037 or approved equivelent) Item 40.2810 1 EA
390 390 Providing and fixing 15mm diameter C.P. brass angle valve as per following with C.P. copper connecting pipe 375mm long or as require d including nuts, washers, C.P. brass flange, etc. including cutting & making good the walls wherever required, etc. complete in all respects inclusive of cost of all materials, labour, tools, tackles etc. as per specifications and directions of the Engineer-in-Ch arge. Item 40.2820
391 391 Angle Valve (Ref. Make: JAQUAR, Model: Cat. No. 0053 or approved equivalent) Item 40.2830 103 EA
392 392 Providing and fixing 15mm diameter C.P. brass stop cock with wall flange (Ref. Make: JAQUAR, Model: Cat. No. 0933 or approved equiva lent), male end with C.P. copper connecting pipe 375mm long or as required including nuts, washers, C.P. brass flange etc. including cutting & making good the walls wherever required complete in all respects inclusive of cost of all materials, labour, tools, tackl es etc. as per specifications and directions of the Engineer-in-Charge. Item 40.2840 103 EA
393 393 Providing & fixing Angle Valve (Ref. Make: JAQUAR, Model: Cat. No. 563 or approved equivalent) and Health Faucet with flexible tube 8mm diameter x 1.5 m long (Ref. Make: JAQUAR, Model: Cat. No. 549 or approved equivalent). Item 40.2850 1 EA
394 394 Providing and fixing the following washroom fittings, complete in all respects; inclusive of cost of all materials, labour, tools, t ackles etc. as per specifications and directions of the Engineer-in-Charge. : Item 40.2860
395 395 Stainless steel liquid soap container (spring loaded push type) with lid and brackets fixed to P.V.C. cleats with C.P. brass screws, etc. Item 40.2870 62 EA
396 396 C.P. brass double coat hook (Ref. Make: JAQUAR, Model: Cat. No. 1161 or approved equivalent). Item 40.2880 52 EA
397 397 Providing and fixing approved quality C.P. brass Towel Rail of 20mm diameter & 600mm long including C.P. brass brackets fixed with w ooden cleats and C.P. brass screws etc. complete. Item 40.2890 4 EA
398 398 Providing and fixing C.P. brass Towel Ring 300mm diameter, fixed to P.V.C. cleats with C.P. brass screws, etc. complete. Item 40.2900 4 EA
399 399 Providing & fixing 6mm thick, copper back finish, looking mirror of required size, made of float sheet glass of best quality & appro ved make, over 12mm thick marine board fixed to rawl plug with round head screws & washers including teakwood beading with melamine polish all around, complete in all respects inclusive of cost of all materials, labour, tools, tackles etc. as per specifications an d directions of the Engineer-in-Charge. Item 40.2910 8 SQM
400 400 Providing, laying and jointing glazed stoneware pipes Class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cem ent : 1 fine sand) including testing of joints etc. complete : Item 40.2920
401 401 150 mm diameter Item 40.2930 503 M
402 402 200 mm diameter Item 40.2940 383 M
403 403 250 mm diameter Item 40.2950 383 M
404 404 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg a s per standard design : Item 40.2960
405 405 100x100 mm size P-type : Item 40.2970
406 406 With common burnt clay F.P.S. (Non-modular) bricks of class designation 7.5 Item 40.2980 109 EA
407 407 Providing and laying non-pressure NP-2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in t he proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : Item 40.2990
408 408 250 mm dia. R.C.C. pipe Item 40.3000 510 M
409 409 300 mm dia. R.C.C. pipe Item 40.3010 510 M
410 410 Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cem ent mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete. : Item 40.3020
411 411 For pipes 250 to 300 mm diameter Item 40.3030 4 EA
412 412 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 Kg and weight of frame 15 Kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone-III) : 10 graded stone aggregate 40 mm nom inal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design : Item 40.3040
413 413 Inside dimensions 455x610 mm and 45 cm deep for single pipeline : Item 40.3050
414 414 With common burnt clay F.P.S. (Non-modular) bricks of class designation 7.5 Item 40.3060 26 EA
415 415 Inside dimensions 500x700 mm and 45 cm deep for pipeline with one or two inlets : Item 40.3070
416 416 With common burnt clay F.P.S. (Non-modular) bricks of class designation 7.5 Item 40.3080 3 EA
417 417 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diam eter, 1.8 m long complete as per standard design. : Item 40.3090
418 418 With common burnt clay F.P.S. (Non-modular) bricks of class designation 7.5 Item 40.3100 29 EA
419 419 Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/ spigot jointed with stiff mixture of ceme nt mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete. : Item 40.3110
420 420 450 mm dia RCC pipes Item 40.3120 585 M
421 421 Providing and laying Non Pressure NP-4 class (Heavy duty) R.C.C. pipes including collars/ spigot jointed with stiff mixture of cemen t mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete. : Item 40.3130
422 422 600 mm dia RCC pipes Item 40.3140 46 M
423 423 Constructing brick masonry Septic Tank with brickwork in cement mortar 1:6 including R.C.C. 1:2:4 (1 cement : 2 sand : 4 graded coar se aggregate) top slab, C.I. cover all as per standard drawing, etc. complete in all respects inclusive of cost of all materials, la bour, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge. Item 40.3150
424 424 For 30 Users Item 40.3160 2 EA
425 425 For 10 Users Item 40.3170 27 EA
426 426 Constructing percolation pit of size 3.0m diameter and 2.0m deep, filled with 40 mm size brick ballast including providing suitable pre-cast RCC covers with lifting lugs, laying of 150mm diameter x 5.0m long U.P.V.C. pipe embedded in pit/ outlet pipe all complete as per specification and directions of the Engineer-in-Charge. Item 40.3180 28 EA
427 427 Providing and fixing self cleaning S.C.I. heavy quality Floor/ Nahani trap with 100mm diameter inlet and 100mm diameter outlet, 125m m C.P. brass grating (heavy type) with or without vent arm including cost of cutting and making good the walls and floors, jointing with lead caulked joints, connecting with waste water pipe etc. complete in all respects inclusive of cost of all materials, labour, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge. Item 40.3190 113 EA
428 428 Providing and fixing 32mm diameter (Nominal Bore) brass ball valve of approved quality complete with high pressure copper floats, co mplete in all respects inclusive of cost of all materials, labour, tools, tackles, etc. complete as per specifications and direction s of the Engineer-in-Charge. Item 40.3200 27 EA
429 429 Construction of second class brick masonary open surface drain (Size: 200mm wide & 200mm average depth) in cement mortar 1:4 laid ov er a bed of 150mm thick cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including mak ing haunches and providing 15mm thick cement plaster in CM 1:4 (1 cement : 4 coarse sand) with a floating coat of neat cement inside and its top and exposed surfaces, including excavatioin, disposal of the surplus earth up to any lead and lift as per standard desi gn and drawing, complete in all respects inclusive of cost of all labour, materials, carriages, excavation and refilling, curing etc ., as per specifications of the Engineer-in-Charge. Item 40.3210 13945 M
430 430 Constructing Brick Masonary catch pit in cement mortar 1:4 (1 cement : 4 coarse sand) including necessary excavation, 200mm thick fo undation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm size) and inside and top plastering (15mm thic k) with cement mortar 1:4 (1 cement : 4 coarse sand) finished with a floating coat of neat cement making necessary connections to dr ains inclusive of all labour, material, equipment, etc., all complete as per drawing and directions of the Engineer-in-Charge. Item 40.3220
431 431 750mm x 750mm x depth up to 1000mm inner dimensions Item 40.3230 26 EA
432 432 600mm x 600mm x depth up to 750mm inner dimensions Item 40.3240 33 EA
433 433 Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and lengt h below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the le ngth of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads [No tes: (1) Length of pile for payment shall be measured up to bottom of pile cap. (2) Truck Mounted rotary/ TMR/ Tubewell boring machi ne shall not be used] : Item 40.3250
434 434 450 mm diameter piles Item 40.3260 4890 M
435 435 Vertical load testing of piles in accordance with IS:2911 (Part-IV) including installation of loading platform by Kentledge/ Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per sp ecification & the direction of the Engineer-In-Charge. [Notes : (1) Initial and Routine Load Test shall not be carried out by Dynami c method of testing. (2) Testing agency shall submitt the design of loading platform for the approval of the Engineer-In-Charge.] : Item 40.3270
436 436 Single pile up to 50 tonne Safe Capacity : Item 40.3280
437 437 Initial Test (Test Load 2.5 times the Safe Capacity). (Note: Unit "EA" shall mean "PER TEST"). Item 40.3290 25 EA
438 438 Routine Test (Test Load 1.5 times the Safe Capacity). (Note: Unit "EA" shall mean "PER TEST"). Item 40.3300 25 EA
439 439 Single pile above 50 tonne and up to 100 tonne Safe Capacity : Item 40.3310
440 440 Initial Test (Test Load 2.5 times the Safe Capacity). (Note: Unit "EA" shall mean "PER TEST"). Item 40.3320 2 EA
441 441 Routine Test (Test Load 1.5 times the Safe Capacity). (Note: Unit "EA" shall mean "PER TEST"). Item 40.3330 2 EA
442 442 Cyclic vertical load testing of pile in accordance with IS Code of practice IS:2911 (Part-IV) by Kentledge method including preparat ion of pile head etc. for : Item 40.3340
443 443 Single pile : Item 40.3350
444 444 Up to 50 tonne Safe Capacity pile. (Note: Unit "EA" shall mean "PER TEST"). Item 40.3360 1 EA
445 445 Group of two or more piles : Item 40.3370
446 446 Up to 400 tonne Safe Capacity of group. (Note: Unit "EA" shall mean "PER TEST"). Item 40.3380 1 EA
447 447 Lateral load testing of single pile in accordance with IS Code of practice IS:2911 (Part-IV) for determining safe allowable lateral load on pile : Item 40.3390
448 448 Up to 50 tonne capacity pile. (Note: Unit "EA" shall mean "PER TEST"). Item 40.3400 25 EA
449 449 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neopre ne gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural d rawings and the directions of the Engineer-In-Charge. (Glazing, paneling and dash fasteners to be paid for separately) : Item 40.3410
450 450 For fixed portion : Item 40.3420
451 451 Powder coated aluminium (Minimum thickness of powder coating 50 micron) Item 40.3430 2038 KG
452 452 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittin gs wherever required including the cost of EPDM rubber/ neoprene gasket required. (Fittings shall be paid for separately) : Item 40.3440
453 453 Powder coated aluminium (Minimum thickness of powder coating 50 micron) Item 40.3450 3036 KG
454 454 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket et c. complete as per the architectural drawings and the directions of Engineer-In-Charge. (Cost of aluminium snap beading shall be pai d in basic item) : Item 40.3460
455 455 With float glass panes of 5.50 mm thickness Item 40.3470 650 SQM
456 456 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS:6315, having brand logo embossed on the body/ plate with double spring mechanism and door weight up to 125 Kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-In-Charge. : Item 40.3480
457 457 With stainless steel cover plate minimum 1.25 mm thickness Item 40.3490 149 EA
458 458 Providing and fixing stainless steel (SS 304 Grade) adjustable friction windows stays of approved quality with necessary stainless s teel screws etc. to the side hung windows as per direction of the Engineer-In-Charge complete. : Item 40.3500
459 459 205 X 19 mm Item 40.3510 66 EA
460 460 Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete as per d irection of the Engineer-In-Charge. Item 40.3520
461 461 Powder coated (Minimum thickness 50 micron) aluminium tubular handle bar Item 40.3530 169 EA
462 462 Providing and fixing 100 mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making g ood etc. complete. Item 40.3540 138 EA
463 463 Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complet e. Item 40.3550
464 464 Powder coated (Minimum thickness 50 micron) Aluminium Item 40.3560 92 EA
465 465 Providing and fixing aluminium round shape handle of outer diameter 100 mm with SS screws etc. complete as per direction of the Engi neer-In-Charge. Item 40.3570
466 466 Powder coated (Minimum thickness 50 micron) Aluminium Item 40.3580 78 EA
467 467 Filling the gap in between Aluminium/ Stone/ Wood frame and adjacent RCC/ Brick/ Stone/ Wood/ Ceramic/ Gypsum work by providing weat her/ structural non-sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of th e Engineer-In-Charge complete, complying to ASTM C920, DIN 18540-F & ISO 11600. Item 40.3590
468 468 Up to 5 mm depth and 5 mm width Item 40.3600 530 M
469 469 Providing and fixing, on fixed glazing/ doors/ window panes, sun control film "HP NATURAL 35 SAFETY COMBINATION FILM-4Mil" of M/s. G ARWARE or approved equivalent make and shade, all complete as per manufacturer's specification and as per instructions of the Engine er-in-Charge. Item 40.3610 586 SQM
470 470 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, blac k finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of me mbrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemi cal parameters of the membrane shall be as under : (a) Joint strength in longitudinal and transverse direction at 23°C as 650/450N/5 cm. (b) Tear strength in longitudinal and transverse direction as 300/250N. (c) Softening point of membrane not less than 150°C. (d) Cold flexibility shall be up to -2°C when tested in accordance with ASTM, D-5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : Item 40.3620
471 471 3 mm thick Item 40.3630 4351 SQM
472 472 Supplying and using water proofing compound like CICO, PUDDLE or any other approved brand with Cement Plaster/ CC/ RCC complete in a ll respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of the Sit e Engineer. Item 40.3640 4301.44 KG
473 473 Boring/ drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS:2800 (Part-I), including c ollecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all eq uipment, tools, plants & machineries required for the job, all complete as per direction of the Engineer-In-Charge, up to 90 metre d epth below ground level. Item 40.3650
474 474 All types of soil : Item 40.3660
475 475 300 mm diameter Item 40.3670 140 M
476 476 Rocky strata including boulders : Item 40.3680
477 477 300 mm diameter Item 40.3690 40 M
478 478 Supplying, assembling, lowering and fixing in vertical position in bore well, Un-plasticized PVC medium well casing (CM) pipe of req uired dia, conforming to IS:12818, including required hire and labour charges, fittings & accessories etc. all complete, for all dep ths, as per direction of the Engineer-In-Charge. Item 40.3700
479 479 150 mm nominal size diameter Item 40.3710 140 M
480 480 Supplying, assembling, lowering and fixing in vertical position in bore well Un-plasticized P.V.C. medium well screen (RMS) pipes wi th ribs, conforming to IS:12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per d irection of the Engineer-In-Charge. Item 40.3720
481 481 150 mm nominal size diameter Item 40.3730 40 M
482 482 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of the Engineer-In-Charge. Item 40.3740 28 CUM
483 483 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulde rs, in required thickness, for all leads & lifts, all complete as per direction of the Engineer-In-Charge. Item 40.3750 28 CUM
484 484 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of the Engineer-In-Charge. Item 40.3760 28 CUM
485 485 Gravel packing in tubewell construction in accordance with IS:4097, including providing gravel fine/ medium/ coarse, in required gra ding & sizes as per actual requirement, all complete as per direction of the Engineer-In-Charge. Item 40.3770 6 CUM
486 486 Development of tube well in accordance with IS:2800 (Part-I) and IS:11189, to establish maximum rate of usable water yield without s and content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, including disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of the E ngineer-In-Charge. (Note: Unit "H" shall mean "PER HOUR"). Item 40.3780 60 H
487 487 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, remova ble as per requirement, all complete for borewell of : Item 40.3790
488 488 150 mm diameter Item 40.3800 2 EA
489 489 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS:2800 (Part-I), including ne cessary bolts & nuts of required size complete. : Item 40.3810
490 490 150 mm clamp Item 40.3820 2 EA
491 491 Providing and fixing Bail plug/ Bottom plug of required diameter to the bottom of pipe assembly of tubewell as per IS:2800 (Part-I). : Item 40.3830
492 492 150 mm diameter Item 40.3840 2 EA
493 493 Supplying, providing, installation, testing & commissioning of sub-mersible pump-cum-motor of approved make capable of delivering 30 0 Litre Per Minute (LPM) to required head with starter, wiring from starter to motor and incoming feeder to starter including pipe w ith all attachment complete in all respects inclusive of cost of all labour, materials, tools, tackles, etc. as per drawings, specif ications and directions of the Engineer-in-Charge. Item 40.3850
494 494 10.0 HP Item 40.3860 2 EA
495 495 Supplying and providing non-shrinkable cement grout (SHRINKKOMP 20 or any other equivalent approved brand) for grouting holding down bolts in pocket holes for equipment foundation, including necessary surface preparation mixing of grout, curing as per manufacturer 's recommendation/ specification and direction of the Site Engineer. (Note: This item shall be operated under specific instruction o f the Engineer-in-Charge.) Item 40.3870 526 KG
496 496 Providing & installing 800 mm dia. stone columns of approximate depth 10 m from the bottom of trench (as per drawing) with well grad ed stone of 100 mm down size as per approved construction procedure including all labour, materials, transportation, consumables, e quipment, mobilisation and de-mobilisation of equipment, disposal of surplus materials, cost of all tests, stacking of stones for me asurement etc. complete in all respect as per specification, approved drawings & directions of the Engineer-in-Charge. Item 40.3880 1.5 M
497 497 Supply and construction of sand pad foundation consisting of well graded coarse sand spread in layers not exceeding 200 mm in loose thickness over the area, so as to achieve relative density of 90% as indicated in drawing including all materials, labour, equipment (like vibratory roller, vibro-rammer & vibrators, etc.) transportation, tests, lead and lift etc. as per specifications and directi ons of the Site Engineer/ Engineer-in-Charge complete up to the satisfaction of Engineer-in-Charge. Item 40.3890 1.8 CUM
498 498 Supplying and laying of 75 mm thick Anticorrosive bituminous carpet under steel storage tanks (i.e. over compacted moorum) with scre ened dry coarse sand mixed with bitumen, dressing to the required slopes to form hard mass of specified compacted thickness using ro llers/ rammers all complete as per specifications and directions of the Site Engineer/ Engineer-in-Charge. Item 40.3900 0.39 SQM
499 499 Supply and constructing a Crushed Stone Ring Beam below each tank shell, all-round, consisting of crushed stone of size 50 mm down l aid in two layers (each layer duly compacted to form a hard core ring), filling of voids/ pockets with medium to coarse sand, cappin g with a compacted sand layer all complete as per drawing, specifications and direction of the Site Engineer/ Engineer-in-Charge. Item 40.3910 0.46 CUM
500 500 Construction of open surface drain complete as per drawing including necessary excavation, refilling, disposal of surplus earth, pro viding and laying one layer of flat brick and cement concrete 1:3:6 (150 mm thick) at bottom, lining with brick masonry in cement mo rtar 1:4 (1 cement : 4 coarse sand), plastering exposed surface with 18 mm thick cement mortar 1:4 1:4 (1 cement : 4 coarse sand) wi th a floating coat of neat cement, rounding off corners etc. complete as per specification, drawing and directions of the Site Engin eer/ Engineer-in-Charge. Item 40.3920
501 501 450 mm x 450 mm rectangular section radial drain. Item 40.3930 910 M
502 502 Providing and making Construction/ Contraction joint by mechanically cutting 12mm x 25mm deep groove and filling with bituminous sea ling compound including cleaning etc. complete as per drawing, specifications and directions of the Engineer-in-Charge. Item 40.3940 4510 M
503 503 Providing and fixing 75mm diameter P.V.C. pipe (4 Kg/sq.cm) for Weep Holes in Masonry/ RCC wall including providing 230x230x230 mm s ize (approx.) filter using pebles of 40mm & down size in every weep hole on retaining side etc. complete in all respects inclusive o f cost of all materials, labour, tools, tackles etc. as per specifications and directions of the Engineer-in-Charge. Item 40.3950 3063 M
504 504 Supply, installation, testing & commissioning of Turbo Roof Air Ventilators of Fan Size- 24 inch (neck/ throat dia.), Ventilator Dia meter- 30 inch, Ventilator Base (FRP)- standard width 1.8m x dome height 750mm, Opening for ventilation dome- 860mm x 680mm x 608mm, thickness 2mm etc. complete in all respects and as per specifications and directions of the Engineer-in-Charge. Item 40.3960 4 EA
505 505 Electrical - TCP Works Item 00050
506 506 10 SERVICES Item 50.A
507 507 Pipe to Soil potential Readings : Measurement, recording and submission of Pipe to Soil Potential readings by connecting / disconnec ting the Mg anodes (for achieving optimal protection through TLPs) along the entire pipeline and at stations, including preparing an d submiting relative PSP profile and other relevant data pertaining to the cathodic protection of the pipeline, including cost of al l labour, instruments and services rendered. The readings shall be furnished as per the specifications and as per the directions of the Site Engineer/Engineer-in-Charge. Item 50.A.10 1444 EA
508 508 Conducting Pearson Survey over the buried line in the right of way including the cost of all competent manpower, transportation and camping facilities etc. to their employees, materials, test instruments, equipments, consumables etc., required for the survey as pe r the standard specifications, identification of areas/locations where coating repair is required alongwith suggestion for remedial measures etc. including the submission of draft reports in 2 sets and incorporation of owner's comments in the draft report and fina l reports in 3 sets including one reproducible containing the survey results complete in all respects Item 50.A.20 275 KM
509 509 20 COMPOSITE Item 50.B
510 510 Magnesium Anode : Supply, Installation , testing and commisioning of Magnesium anode (minimum 5 Kg each) including its tail cable o f size of 1c x 10 sq.mm. XLPE/ PVC insulated stranded copper cable of total length 10 meter including PVC cap, special back-fill mat erial ( filled in cotton sack) with sealing compound complete in all respect including its excavations, back filling etc. as per spe cifications and drawings. The work complete in all respect shall include supply of all labour , tools etc. and shall be carried out as per the directions of the EIC/ Site Engineer and as per AFC drawings. Item 50.B.10 357 EA
511 511 Test Lead Point : Supply, installation, testing & commissioning of Test Lead Point (TLP) fabricated MS Sheet (Thickness : 3 mm top/ side/rear/front & 5 mm : Bottom plates) with hinged front door, Heavy Guage MS pipe 100 mm nominal diameter, Phenolic laminated term inal plate, brass terminal bolts, neoprene gasket for front door, vandal proof concealed lock, etc as per latest revision of Standar d AFC drawing (9200-99900-404-603-03 : STD-483). The work includes providing requisite concrete foundation of 600 mm x 600 mm x 800 mm at site, including MS hard pipe for cable entry through foundation, erection of the TLP over concrete foundation, termination o f cables to the brass terminal bolts inside TLP box, jointing the cables to pipe (using cad welding/ pin brazing technique), repair ing the damage to coat & wrap (with coating repair etc.), back filling the trenches, cleaning the site, applying epoxy paint / powd er coating etc. The work also includes supply, installation, laying & termination of all XLPE, Cu cables of required length (as per site conditions) and size, lugs etc. The work includes supply and fixing of a non-corrosive name plate containing the details like K M location, identification, TLP No., direction of flow, connection scheme, type etc., on the side of the TLP box, etc. The name plat e shall also include the details of corrosion coupon wherever installed, all as per the direction and specification detailed in the document complete with tools, tackles & other necessary requirement. The work complete in all respects including all materials, tool s, tackles, labour as per tender specifications, AFC drawings & directions of the Site Engineer/Engineer-In-Charge. Item 50.B.20
512 512 Type A (With Ingress Protection IP:55) Item 50.B.30 207 EA
513 513 Type B (With Ingress Protection IP:55) Item 50.B.40 154 EA
514 514 Type C (With Ingress Protection IP:55) Item 50.B.50 14 EA
515 515 Type D (With Ingress Protection IP:55) Item 50.B.60 2 EA
516 516 Type DAC (With Ingress Protection IP:55) Item 50.B.70 76 EA
517 517 Flameproof Type E (With Ingress Protection IP:55) - with inbuilt provision of Voltmeter and Pushbutton for PSP Measurment. Item 50.B.80 32 EA
518 518 Flameproof Type DMV (With Ingress Protection IP:55) - with inbuilt provision of Voltmeter and Pushbutton for PSP Measurment. Item 50.B.90 32 EA
519 519 Supply and Installation of CS corrosion coupon with 1 sq. cm bare metal with 2 numbers 4 sq. mm lead of minimum 10 m long lead wit h in a distance of 0.5 M from the pipeline inclusive of cable & terminating the cable in the TLP terminal. The corrosion coupons are to be installed with specified Test lead points for which prior approval to be obtained from Owner. The item also includes supply, installation / laying & termination of all XLPE, Cu cables of required length (as per site conditions) and size as mentioned in the standard drawings, toggle switch, cable glands and lugs etc., complete in all respect. All as per the direction and specification de tailed in the document complete with tools, tackles & other necessary requirement for preparation of the coupon. The work complete i n all respect shall include supply of all labour, tools etc complete as per the directions of the Site Engineer and as per drawing n o. 9200-99900-404-601-08. Item 50.B.100 131 EA
520 520 Electrical - PCP Works Item 00060
521 521 10 SUPPLY Item 60.A
522 522 "PERMANENT CATHODIC PROTECTION SYSTEM Supply of materials/equipments as given below complete in all respects, as per the specification as detailed in the tender document including transportation to site and storing :" Item 60.A.10
523 523 "Solid State Decoupling Device:- Supply of Solid State Diode Decoupling Device of approved make including required length of cable as per specifications for protecti on of MOVs and at HT line crossing locations" Item 60.A.20 172 EA
524 524 "Supply of Surge Arrestors of approved make including required length of cable & as per specifications for protection of insulating couplings:- Spark Gap Surge Arrestorfor above ground and under ground suitable for 100 kA lightening Impulse Current (10/350 micro s), rated spa rk over voltage <= 1.25 kV with connecting cable (EXFS 100 KU of Dehn or eq.)" Item 60.A.30 58 EA
525 525 Supply of Cathodic Protection unit of approved make, complete in all respects as given in the specification with all its accessories to ensure trouble free operation Item 60.A.40
526 526 48 V DC Operated automatic type Cathodic Protection Power Supply Module (CPPSM) unit of rating 25 V, 25 A DC with with DC-DC convert er & SCADA linkage facility as per specifications Item 60.A.50 6 EA
527 527 230 V AC Operated automatic type Cathodic Protection Transformer Rectifier (CPTR) unit of rating 25 V,25 A DC with SCADA linkage fac ility as per specifications Item 60.A.60 1 EA
528 528 230 V AC Operated automatic type Cathodic Protection Transformer Rectifier (CPTR) unit of rating 50 V,50 A DC with SCADA linkage fac ility as per specifications Item 60.A.70 1 EA
529 529 Supply of junction box of approved make as per specification detailed in the tender document complete with all connecting terminal & shunts, other fittings, DC bus, MS plate box, bakelite terminal board, cable termination bolts, painting etc. Item 60.A.80
530 530 Junction Box having IP-55 degree of protection Item 60.A.90 1 EA
531 531 Flameproof,Ex-d,IIA/IIB & Weather proof junction Box of approved make conforming to drg 9200-999000-40402-292-00. Item 60.A.100 16 EA
532 532 Flameproof,Ex-d,IIA/IIB CJB with accessories for distribution of current among pipelines Item 60.A.110 4 EA
533 533 Supply of wall mounted DC distribution board of approved make in IP-42 ingress protection for power supply to CP equipments as given in technical specifications DC distribution board with one incomer, 100 A DP MCB & outgoing feeders 1x63A DP MCB & 2x32 A DP MCB Item 60.A.120 1 EA
534 534 Supply of XLPE insulated , PVC sheathed cable, 1100 v grade conforming to IS: 7098 (P-1) as per specifications and approved make Item 60.A.130
535 535 Copper Cable size 1cx35 sq. mm Armoured Item 60.A.140 4500 M
536 536 Copper Cable size 1cx25 sq.mm Armoured Item 60.A.150 100 M
537 537 Copper Cable size 2cx6 sq.mm Armoured Item 60.A.160 7500 M
538 538 Copper Cable size 2cx70 sq.mm Armoured Item 60.A.170 300 M
539 539 Tinned Copper Cable size 1cx10 sq.mm Unarmoured for distributed anodes of station CP system Item 60.A.180 150 M
540 540 Supply of Cu- CuSO4 Half cell as per specifications of approved make Item 60.A.190
541 541 PERMANENT HALF CELL:- Supply of Cu- Cuso4 permanent Half cell with minimum 10 m length of tail cable, as per specifications of app roved make Item 60.A.200 44 EA
542 542 PORTABLE HALF CELL:- Supply of Cu- Cuso4 portable Half cell, as per specifications of approved make Item 60.A.210 4 EA
543 543 Supply of Pipe cum cable locator of approved make as per specifications complete in all respects Item 60.A.220 1 EA
544 544 Supply of hand held data logger for ON/OFF PSP measurement alongwith carrying case, data downloading cable and other required access ories complete as per specifications and approved make Item 60.A.230 2 EA
545 545 Supply of Four pin Soil Resistivity Meter with output maximum 80 wattt / upto 200 mA stabilised current output along with required accessories complete as per specifications and approved make Item 60.A.240 1 EA
546 546 Digital Multimeter with data logging, trend capturing and graphic display facility like Fluke 289 or eq.along with required accesso ries complete as per specifications and approved make Item 60.A.250 2 EA
547 547 20 SERVICES Item 60.B
548 548 "Solid State Decoupling Device:- Installation of solid state decoupling device as per specifications including terminating the cables in the TLP box with cable lugs, sealing material, laying of cable, testing & commissioning of Zinc anodes etc. all complete with required material, excavation, bac kfilling etc. as per specification and directions of Site Engineer/ Engineer-in-Charge." Item 60.B.10 172 EA
549 549 "SURGE ARRESTOR/SPARK GAP ARRESTOR:- Installation of surge arrestors including terminating the cables, laying of cable, testing & commissioning of surge arrestors etc. a ll complete with required material, excavation, backfilling etc. as per specification and directions of Site Engineer / Engineer-in -Charge." Item 60.B.20 58 EA
550 550 "PERMANENT HALF CELL:- Installation of permanent half cells including connecting the cable in the TLP etc. with cable lugs, sealing material, laying of cab le, testing & commissioning of cell etc. all complete with required material, excavation, backfilling etc. as per specifications, r ecommendation of cell supplier and directions of Site Engineer / Engineer-in-Charge." Item 60.B.30 44 EA
551 551 "COATING RESISTANCE SURVEY:- Conducting "" Coating-Resistance Survey"" for calculation of effective coating resistance of the pipeline in ohms-sq.m. along the en tire pipeline and plotting on SEMILOG or X-Y GRAPH & submitting the report in graphical form as well as soft copy as per Specificat ion / approved procedure and directions of Site Engineer / Engineer-in-Charge." Item 60.B.40 275 KM
552 552 "Close Interval ON/OFF Potential logging survey:- Conducting Close Interval ON/OFF Potential Logging Survey at an interval of 1 m over the buried line in the right of way including t he cost of all expert manpower, transportation and camping facilities etc. to their employees, materials, test instruments, equipmen ts, consumables etc., required for the survey as per the standard specifications, and approved procedures identification of areas/lo cations where coating repair is required alongwith suggestion for remedial measures etc. including the submission of draft reports i n 2 sets and incorporation of owner's comments in the draft report and final reports in 6 sets including one soft copy containing th e survey results in the graphical as well as tabular forms computerised colour print and complete in all respects and directions of Site Engineer / Engineer-in-Charge." Item 60.B.50 275 KM
553 553 "Close Interval Natural Potential logging survey:- Conducting Close interval Natural potential logging Survey at an interval of 1 m over the buried line in the right of way including the cost of all expert manpower, transportation and camping facilities etc. to their employees, materials, test instruments, equipme nts, consumables etc., required for the survey as per the standard specifications, and approved procedures identification of areas/l ocations where coating repair is required alongwith suggestion for remedial measures etc. including the submission of draft reports in 2 sets and incorporation of owner's comments in the draft report and final reports in 6 sets including one soft copy containing t he survey results in the graphical as well as tabular forms computerised colour print and complete in all respects and directions of Site Engineer / Engineer-in-Charge. Close Interval Natural Potential logging survey" Item 60.B.60 275 KM
554 554 "Direct Current Voltage Gradient Survey:- Conducting Direct Current Voltage Gradient Survey over the buried line to identify / pin point the coating defects in the right of w ay including the cost of all expert manpower, transportation and camping facilities etc. to their employees, materials, test instrum ents, equipments, consumables etc., required for the survey as per the standard specifications and approved procedures, identificati on of areas/locations where coating repair is required alongwith suggestion for remedial measures etc. including the submission of d raft reports in 2 sets and incorporation of owner's comments in the draft report and final reports in 6 sets including one soft copy containing the survey results in the graphical as well as tabular forms computerised colour print and complete in all respects as p er directions of Site Engineer / Engineer-in-Charge. Note : The item includes establishing the coating defect at specified locations by excavation in coordination with mainline contract or, who will arrange to repair the defects." Item 60.B.70 264 KM
555 555 "CAT survey:- Carrying out the Current Attenuation(CAT) Survey at 50 meters interval by measuring current loss along the mainline pipe and using R adio Detection Instruments. Completing the entire work as per specification and EIC`s direction including all equipments with its ac cessories etc.tools, tackles, Battery transportation (Vehicle), related equipments,consumables, if any labour /manpower and any / al l relevant data collection as may be deemed necessary for carrying out the survey and interpretation /presentation of the results in cluding submission of reports complete in all respect thereof. Also locating the exact position of buried pipeline/defect of Pipelin e coating.Route mapping of the entire stretch at an interval of 10M with the help of GPS instrument (to be arrange by contractor)and submission of the hard and soft copy to the EIC." Item 60.B.80 95 KM
556 556 "MUTUAL INTERFERENCE SURVEY:- Conducting Mututal Interference Survey among the new and existing pipelines / facilities(foreign) by taking PSP survey of all the pi pelines as per approved procedure to determine level of interference at different places along the pipeline and at point of crossi ng in common ROW including identifying points and providing the data/ record in graphical form and carrying out all necessary work for mitigating the interference observed among the pipelines , including retesting the same to ensure efficacy of the remedial measu res undertaken.The contractor shall submit a full final report with detailed PSP readings at all TLPs along with graphs in six sets .The item should be complete in all respect including survey, work for mitigating the interference and post mitigating survey as per specifications/directions of site engineer / Engineer-in-Charge." Item 60.B.90 275 KM
557 557 "AC interference survey:- ""Conducting AC interference survey, to detect presence of any AC voltage(induced owing to proximity of any HT transmission line ( a bove 33kV) crossing or running parallel within a distance of 50 M from the pipeline alignment as per approved procedure. The work s hall be completed in all respects including survey recommending mitigation measures & post mitigation survey. The work includes all tools, tackles, consumables etc. all complete, required for survey / test as deemed necessary and as per the directions of the site engineer / Engineer-in-Charge. Note : AC interference survey shall be done at respective TLP by connecting data logger to maintain r ecord for minimum 24 hours. The data to be submitted for each such TLP alongwith coloured graph and recommendations. AC interference survey""" Item 60.B.100 381 EA
558 558 "Soil resistivity survey:- Conducting ""Soil Resistivity Survey"" at anode bed location after ascertaining its suitablity with respect to the existing system , for installation of Anode Bed (deep / shallow / distributed), as per the specification, approved procedures and instructions of Sit e Engineer / Engineer-in-Charge. Soil resistivity Survey" Item 60.B.110 8 EA
559 559 "Cathodic Protection Units Erection, testing and commissioning of cathodic protection units (CPTR/CPPSM); including supply and installation of all facilities, materials etc., including fuses, all supporting structures, laying and connecting the 1100 V Grade power cable (2 runs of 1Cx25 sqmm Cu. conductor XLPE insulated Armoured Cable) from DCDB to CPPSM unit / laying and connecting the 1100 V Grade power cable (owner pr ovided 1 run of 3Cx10 sqmm Al. conductor XLPE insulated Armoured Cable) from ACDB to CPTR unit, providing the earthing arrangement. The work includes furnishing the test results by conducting all the NO LOAD and ON LOAD tests on the CP units and adjusting setting s as required and testing the pipeline section for full cathodic protection for entire stretch. The job complete in all respect shal l include cost of all labour, tools as per specifications and directions of the Site Engineer / Engineer-in-Charge." Item 60.B.120
560 560 48 V DC operated auto type Cathodic Protection Power Supply Module (CPPSM) unit of rating 25 V 25 A DC with SCADA linking facility Item 60.B.130 6 EA
561 561 230 V AC operated auto type Cathodic Protection Transformer Rectifier (CPTR) unit of rating 25 V 25 A DC with SCADA linking facility Item 60.B.140 1 EA
562 562 230 V AC Operated manual type Cathodic Protection Transformer Rectifier (CPTR) unit of rating 50V, 50A DC Item 60.B.150 1 EA
563 563 "DC distribution board:- Installation and commissioning of wall mounted DCDB including supply of all cable end lugs, cable glands, fittings & fixtures and al l other required accessories, tools and tackles complete in all respects as per directions of Site Engineer/Engineer-in-charge. Item includes supply and termination of 2 runs of 1cx25 sq. mm copper cable for Battery Bank" Item 60.B.160 1 EA
564 564 Installation of Flameproof CJB with accessories for distribution of current among pipelines Item 60.B.170 4 EA
565 565 Laying of anode header / cathode / reference cell cables at a minimum depth of 1 meter and connection to the CP unit / pipeline / ha lf cell etc. The work includes excavation, installation, supply of all required materials such as sealing materials, lugs, PVC sleev e, repair materials etc., and carrying out all works such as exposing pipe, coating repair, cad welding / pin brazing, backfilling e tc.,; in all types of strata and soil (including rock) by making the trench, back filling the trench, cable terminations, work compl ete in all respects including cost of all labour, material, tools etc. as per specification and instruction of Site Engineer / Engin eer-In-Charge and approved drawings. Item 60.B.180
566 566 1cx35 sq. mm Item 60.B.190 4500 M
567 567 1cx25 sq. mm Item 60.B.200 100 M
568 568 2cx6 sq. mm Item 60.B.210 7500 M
569 569 1cx10 sq. mm Item 60.B.220 150 M
570 570 "Cable Laying Laying of all type of cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cable racks, in tra ys, in protective pipes, poles,columns, in conduits, in panels and on structures etc.;including the supply and installation of all r equired materials such as fixing clamps ,screws, cable straps, tags etc. as required (other than the supply of the conduits, ca bles, pipes, cable racks, trays, poles, structures and panels) complete in all respect, including cost of all labour, tools, co nsumable materials etc. and cutting the cables in required lengths as per drawings, specification and directions of Site Engineer / Engineer-in-Charge" Item 60.B.230
571 571 Power cables LT : OD upto 20 mm Item 60.B.240 6300 M
572 572 Power cables LT : OD above 20 mm and upto 40 mm Item 60.B.250 300 M
573 573 "CP Reading :- Measuring, recording and submitting the cathodic protection readings along the entire pipeline by repeated adjustments of the settin gs of the CPTR/CPPSM units etc as per specifications for achieving full/maximum protection of all the stretches as per the criteria of protection mentioned in the specifications. Measuring the relevant readings at the cathodic protection stations and ""pipe to so il potential"" readings at all the test lead locations along the pipeline including the CP station parameters like current(AC/DC), voltage(AC/DC),circuit resistance,battery voltage/current etc.,preparing and submitting pipe to soil potential profile, graphs and other data pertaining to the cathodic protection of the pipeline,job complete in all respects as per specification and instructions of Site Engineer / Engineer-in-Charge, including cost of all labour, instruments and services rendered." Item 60.B.260 275 KM
574 574 "Final Commisioning of CP system Final Commissioning of the impressed current cathodic protection system for the mainline for achieving full protection as per protec tion criteria as mentioned in the specifictions through repeated adjustments of the CP units after installation of galvanic anodes f or hot spot protection and mitigation of AC/ DC interference, if any and submission of the resultant data to the owner and testing, measuring, recording and submitting all these data once again after the lapse of a period as per specifications / directions of the Site engineer / Engineer-in-Charge, including the cost of all labour tools and materials as required, complete in all respect." Item 60.B.270 1 LS
575 575 "Station CP readings and commissioning of station CP system:- Measuring, recording and submitting the cathodic protection readings for the station piping by repeated adjustments of the setting s of the TRUs etc for achieving full/ maximum protection as per the criteria and priority of protection as mentioned in the specifi cations ., measuring the relevant readings and ""pipe to soil potential"" readings at all the test lead locations in the station in cluding the CP station parameters like current(AC/DC), voltage(AC/DC) , circuit resistance etc. , preparing and submitting pipe t o soil potential profile, graphs and other data pertaining to the cathodic protection of the station CP system for all the station CP Systems installed as per respective item, job complete in all respects as per specification and instructions of Site Engineer / E ngineer-in-Charge, including cost of all labour, instruments and services rendered." Item 60.B.280 1 LS
576 576 30 COMPOSITE Item 60.C
577 577 Zinc Anode for Hot spot protection : Supply, Installation , testing and commisioning of Zinc anode (minimum 10 Kg each) including it s tail cable of size of 1c x 25 sq.mm. XLPE/ PVC insulated stranded copper cable of total length 10 meter including PVC cap, special back-fill material ( filled in cotton sack) with sealing compound complete in all respect including its excavations, back filling e tc. as per specifications and drawings. The work complete in all respect shall include supply of all labour , tools etc. and shall b e carried out as per the directions of the Site Engineer / Engineer-in-Charge and as per AFC drawings. Item 60.C.10 431 EA
578 578 Magnesium Anode : Supply, Installation , testing and commisioning of Magnesium anode (minimum 5 Kg each) including its tail cable o f size of 1c x 10 sq.mm. XLPE/ PVC insulated stranded copper cable of total length 10 meter including PVC cap, special back-fill mat erial ( filled in cotton sack) with sealing compound complete in all respect including its excavations, back filling etc. as per spe cifications and drawings. The work complete in all respect shall include supply of all labour , tools etc. and shall be carried out as per the directions of the EIC/ Site Engineer and as per AFC drawings. Item 60.C.20 16 EA
579 579 "Anode-deep well:- Supply & installation of Anode bed ( deep well type with MMO anodes) as per the approved configuration for Impressed Current Cathod ic Protection system including supply, laying & termination of all anodes, anode tail cable (XLPE insulated copper conductor) suita ble with length for connecting upto Anode junction box without any joints in between including laying of PVC sleeve / trunk pipe, c asing pipe , centralizers, vent pipe & drawing all the lead wires through the pipe and connecting the same with Anode bus in Anode junction box including erection and providing foundation of Anode Junction Box as per specifications inlcuding supply, excavation, backfill of earth etc. as per specification & also compacting the same with soil for restoring it to normal finished ground level all complete with all labour & material as per instruction of Site Engineer / Engineer-in-Charge, Specifications and approved drawi ngs. Note : Each Anode bed means anode bed at each location irrespective of number of anode strings required." Item 60.C.30 6 LS
580 580 "Mainline CP : Anode bed shallow type:- Supply & installation of Anode bed ( shallow type ) as per the approved configuration for 'Impressed Current Cathodic Protection' s ystem including supply, laying & termination of all anodes, anode tail cable (XLPE insulated copper conductor) suitable with length for connecting upto Anode junction box without any joints in between including laying of PVC sleeve / trunk pipe & drawing all the lead wires through the pipe and connecting the same with Anode bus in Anode junction box including erection, providing foundations of Anode Junction Box, chain link fencing around anode junction box wherever required, as per specifications including supply of ba ck fill material, excavation, backfill of earth and filling the sand with requisite back fill material as per specification & also c ompacting the same with soil for restoring it to normal finished ground level all complete with all labour and material as per inst ruction of Site Engineer / Engineer-in-Charge, Specifications and approved drawings. Note : Each Anode bed means anode bed at each location irrespective of number of anode strings required." Item 60.C.40 1 LS
581 581 "Station : Distributed type shallow:- Supply & installation of MMO type anodes as per the approved configuration for 'Impressed Current Cathodic Protection' system of st ation piping / structures including all anodes, laying & termination of all anode tail cable (XLPE insulated copper conductor) suita ble with length for connecting upto Anode junction box without any joints in between including supply and laying of PVC sleeve / tr unk pipe & drawing all the lead wires through the pipe and connecting the same with Anode bus in Anode junction box including erect ion, providing foundations of Anode Junction Boxes & Cathode Junction Boxes, providing chain link fencing around Anode junction Box wherever required, as per specifications including supply of back fill material, excavation, backfill of earth and filling the sand with requisite back fill material as per specification & also compacting the same with soil for restoring it to normal finished gro und level all complete with all labour and material as per instruction of Site Engineer / Engineer-in-Charge, Specifications and ap proved drawings. Note : Supply of anode tail cable for distributed anodes for station CP are covered elsewhere in SOR" Item 60.C.50 1 LS
582 582 Test Lead Point : Supply, installation, testing & commissioning of Test Lead Point (TLP) fabricated MS Sheet with hinged front door , Heavy Guage MS pipe 100 mm nominal diameter, Phenolic laminated terminal plate, brass terminal bolts, neoprene gasket for front do or, vandal proof concealed lock, etc as per latest revision of Standard AFC drawing (9200-99900-404-603-03 : STD-483). The work inc ludes providing requisite concrete foundation of 600 mm x 600 mm x 800 mm at site, including MS hard pipe for cable entry through f oundation, erection of the TLP over concrete foundation, termination of cables to the brass terminal bolts inside TLP box, jointing the cables to pipe (using cad welding/ pin brazing technique), repairing the damage to coat & wrap (with coating repair etc.), back filling the trenches, cleaning the site, applying epoxy paint / powder coating etc. The work also includes supply, installation, l aying & termination of all XLPE, Cu cables of required length (as per site conditions) and size, lugs etc. The work includes supply and fixing of a non-corrosive name plate containing the details like KM location, identification, TLP No., direction of flow, connec tion scheme, type etc., on the side of the TLP box, etc. The name plate shall also include the details of corrosion coupon wherever installed, all as per the direction and specification detailed in the document complete with tools, tackles & other necessary requir ement. The work complete in all respects including all materials, tools, tackles, labour as per tender specifications, AFC drawings & directions of the Site Engineer/Engineer-In-Charge. Item 60.C.60
583 583 Type A (With Ingress Protection IP:55) Item 60.C.70 1 EA
584 584 TLP type "A" , Flameproof,Ex-d,IIA/IIB & weather proof as per specifications and drawing (With inbuilt provision of Voltmeter & push button for PSP Measurment) Item 60.C.80 10 EA
585 585 Type B (With Ingress Protection IP:55) Item 60.C.90 1 EA
586 586 Type B (Flameproof,Ex-d,IIA/IIB & weather proof as per specifications and drawing) Item 60.C.100 20 EA
587 587 Type C (With Ingress Protection IP:55) Item 60.C.110 1 EA
588 588 Type D (With Ingress Protection IP:55) Item 60.C.120 1 EA
589 589 Type DAC (With Ingress Protection IP:55) Item 60.C.130 1 EA
590 590 Flameproof,Ex-d,IIA/IIB Type DMV (With Ingress Protection IP:55) - with inbuilt provision of Voltmeter and Pushbutton for PSP Measu rment. Item 60.C.140 1 EA
591 591 Flameproof,Ex-d,IIA/IIB Type E (With Ingress Protection IP:55) - with inbuilt provision of Voltmeter and Pushbutton for PSP Measurme nt. Item 60.C.150 1 EA
592 592 "Corrosion coupon:- Supply and Installation of CS corrosion coupon with 1 sq. cm bare metal with 2 numbers 4 sq. mm lead of minimum 10 m long lead wit h in a distance of 0.5 M from the pipeline inclusive of cable & terminating the cable in the TLP terminal. The corrosion coupons are to be installed with specified Test lead points for which prior approval to be obtained from Owner. The item also includes supply, installation / laying & termination of all XLPE, Cu cables of required length (as per site conditions) and size as mentioned in the standard drawings, toggle switch, cable glands and lugs etc., complete in all respect. All as per the direction and specification de tailed in the document complete with tools, tackles & other necessary requirement for preparation of the coupon. The work complete i n all respect shall include supply of all labour, tools etc complete as per the directions of the Site Engineer and as per drawing n o. 9200-99900-404-601-08." Item 60.C.160 1 EA
593 593 "Cable Marker Supply, erection and installation of MS cable markers; including excavation,installation of the markers,cement concrete grouting, back-filling etc. required as per drawings, specifications and directions of the Site Engineer,including the cost of all ma terials, labour,tools etc. complete in all respects as per the directions of Site Engineer / Engineer-in-Charge." Item 60.C.170 120 EA
594 594 PSP and DC pipeline current display meter:-Supply , installation, testing & commissioning of PSP display meter along with enclosure having microprocessor based unit with built-in GSM modem or ethernet connectivity, data logger facility with SD card memory of minim um 8 GB, high accuracy built-in The Real time clock(RTC) and provision for data transmission to SCADA system as per the direction an d specification detailed in the document. The work complete in all respects including all materials, tools, tackles, labour as per t ender specifications, AFC drawings & directions of the Site Engineer/Engineer-In-Charge Item 60.C.180 1 EA
595 595 "Signal Isolators:-Supply,installation,testing & commissioning of two seperate 4-20mA converters((0 to 20 mV) & (0 to -2V) Input res pectively, 2x(4to20 mA) Output in each converter) in pre installed TLPs at SV/IPIG/CP locations as per the approved drawings and specification detailed in the document. The work complete in all respects including all materials, tools, tackles, labour as per ten der specifications, AFC drawings & directions of the Site Engineer/Engineer-In-Charge." Item 60.C.190 27 SET
596 596 Electrical - CSW Item 00070
597 597 10 SUPPLY Item 70.A
598 598 "SAFETY EQUIPMENT :- Supplying the following Safety Equipment as per directions of Site Engineer / Engineer-in-Charge" Item 70.A.10
599 599 RUBBER HAND GLOVES : Rubber hand gloves suitable for 11/6.6 KV operation with ISI mark. Item 70.A.20 28 SET
600 600 Supply and installation of 11/6.6 KV Discharge Rod Item 70.A.30 1 SET
601 601 Insulating Elastomer mats conforming to IS 15652:2006 of thickness 2 mm (Class A) Item 70.A.40 305 EA
602 602 Insulating Elastomer mats conforming to IS 15652:2006 of thickness 2.5 mm (Class B) Item 70.A.50 2 EA
603 603 Supply of fully charged CO2 fire extinguishers as per specifications (4.5 kg capacity as per IS: 2878 latest) Item 70.A.60 58 EA
604 604 Supply of fully charged CO2 fire extinguishers as per specifications (2 kg capacity as per IS: 2878 latest) Item 70.A.70 56 EA
605 605 Supply of fire buckets mounted on stand Item 70.A.80 56 EA
606 606 "The flameproof (Ex'd) and weatherproof (Minimum IP-65) Distribution Boards (with Spares) made up of Cast Alluminium Alloy LM-6 with 125 A, TPN busbar, 01 no. 100 Ampere, 4 Pole MCCB suitable for termination of cable of size up to 3.5Cx50 sqmm, Aluminium Armoured cable. 01 additional spare entry suitable for 3.5CX50sqmm cable size shall be provided, which shall be plugged with flameproof and weatherproof entry plug. 09 Nos. 32A, 3 Pole MCBs suitable for termination of 3C x 10 sq.mm., Armoured cable Breaking capacity of MC B shall be 10 kA for 1 Sec and shall be C-curve application suitable for motor duty. It shall be certified for application in Zone-I , Gas Group IIA & IIB, Temp class T3 and shall be of approved make as mentioned in the technical specifications. The item includes suply of flame proof double compression cable glands of nickel plated brass material for each cable entry 01 no. for cable entry of size up to 3.5C x 50 sq.mm., 02 no for 3.5 C x 25 Sq mm cable, 09 no. for 3Cx10 sqmm, Aluminium armoured cable. Cable dimensions sha ll be provided at drawings approval stage. Supply shall be as per technical specifications of flameproof DB attached with supply spe cifications." Item 70.A.90 4 EA
607 607 20 SERVICES Item 70.B
608 608 CABLE TRENCH :-Excavation in unpaved areas of earth in work sites for conventional cable trenches for a depth upto 1.5 metres incl uding shoring, strutting etc. (if necessary), backfilling the trench, job complete in all respects, including all labour and m aterials complete as per drawings, specification and directions of Site Engineer / Engineer-in-Charge Item 70.B.10 6155 M3
609 609 WBM ROAD / CONCRETE BREAKING : WBM Road/concrete breaking for cable trenches including required shoring strutting etc., and repairin g of the road/dyke to original condition and disposing off excess materials (within the work site) job complete in all respe cts including the cost of labour, tools, materials, load, lift hire charges of equipments, if any, complete as per drawings, sp ecification and directions of Site Engineer / Engineer-in-Charge Item 70.B.20 197 M3
610 610 "Cable Laying Laying of all type of cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cable racks, in tra ys, in protective pipes, poles,columns, in conduits, in panels and on structures etc.;including the supply and installation of all r equired materials such as fixing clamps ,screws, cable straps, tags etc. as required (other than the supply of the conduits, ca bles, pipes, cable racks, trays, poles, structures and panels) complete in all respect, including cost of all labour, tools, co nsumable materials etc. and cutting the cables in required lengths as per drawings, specification and directions of Site Engineer / Engineer-in-Charge" Item 70.B.30
611 611 Power cables LT : OD upto 20 mm Item 70.B.40 55000 M
612 612 Power cables LT : OD above 20 mm and upto 40 mm Item 70.B.50 23000 M
613 613 Power cables LT : OD above 40 mm and upto 60 mm Item 70.B.60 200 M
614 614 Power cables HT Item 70.B.70 200 M
615 615 Control cables (T&I) : OD upto 20 mm Item 70.B.80 29450 M
616 616 Control cables (T&I) : OD above 20 mm and upto 30 mm Item 70.B.90 21940 M
617 617 Installation, laying of 2 Pair PVC insulated copper conductor un-armoured telephone cables in 16 mm/ 25 mm/ 32 mm PVC conduits from IDF through ceiling/ wall/trench and post-laying end to end testing of telephone cables. The job includes supply, installation, fix ing of wall mounted telephone socket outlet with 2 port telephone jack face plate (white/ cream colour) including RJ11 I/O with modu lar plate & switch box/ gang box for fixing the face plate & accessories, supply and installation of PVC Conduits, all required mate rials such as fixing clamps, screws, cable straps, tags etc. as required complete in all respects as per specifications & scope of work, drawings and directions of Site Engineer/ Engineer-in-charge including cost of all labour, tools & tackles, materials etc. Item 70.B.100 3000 M
618 618 Installation, laying of Cat 6 LAN Cables in 16 mm/ 25 mm/ 32 mm PVC conduits from network switch through ceiling/wall/trench and pos t-laying end to end testing of cables. The job includes installation & fixing of Duplex (2 port) Face plate (Network I/O point) (whi te/ cream colour) for Local Area Network including RJ45 I/O, modular plate & switch box/ gang box for fixing the face plate & access ories, supply and installation of PVC Conduits, all required materials such as fixing clamps, screws, cable straps, tags etc. as req uired complete in all respects as per specifications & scope of work, drawings and directions of Site Engineer/ Engineer-in-charge i ncluding cost of all labour, tools & tackles, materials etc. Item 70.B.110 3000 M
619 619 Silent LT DG set : Erection, Installation including site transportation from owner designated location, connecting, testing and commissioning of owner supplied Emergency LT DG set including execution of terminal connection of power/control cable. The work shall include grounding of alternator neutral, earthing, providing water pipe connection for Radiator water make-up complete with valve, solenoid valve etc. piping for fuel line, fabrication, welding, erection and painting of owner supplied support structure (including supply of shortfall support structure, if any) for exhaust piping, mounting on channels/AVM pads, installation of PLC based AMF panel, NIG panel, exhaust piping including insulation and cladding, fuel piping etc., materials, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge Item 70.B.120 28 EA
620 620 Connection and testing of 415 V AC 3 phase / 230 V AC single phase motors (including space heaters/thermistors wherever provided) / AC/DC Actuators including execution of terminal connection of control and power cables, earthing of the motor/actuator/ connecting t he thermistor, installing the controller in LT panel, earthing the motor frame, armour etc. as per the drawings, erection manuals, a nd as per directions of Site Engineer. Job complete in all respects including the cost of supplying and installation of all the requ ired FLP/WP cable glands, reducers, adapeters, end lugs, GI earthing wire / strips, labour, tools, materials, etc., as required in a ll respects for all types of motors/heaters/thermistors/actuators etc. Item 70.B.130
621 621 Capacity upto and including 1 KW Item 70.B.140 2 EA
622 622 Capacity above 1 KW and upto 2.5 KW Item 70.B.150 130 EA
623 623 Capacity above 2.5 KW but upto 7.5 KW Item 70.B.160 4 EA
624 624 Capacity above 7.5 KW but upto 50 KW Item 70.B.170 4 EA
625 625 "LT Panel: Erection, installation including site transportation from owner designated location, testing and commissioning of 415 V, owner supplied power-control- centres, motor control centres, soft starters,static voltage regulators, APFC panel etc. assembling as required, installation on the already made foundation channels, aligning, levelling, grouting, assembling, making all the inter connections /outgoing/incoming power & control cable/ bus duct connection including making holes for cable entries as required as per drawing, specifications and directions of the Site Engineer/Engineer-in-Charge including cost of all materials, tools labour etc. complete in all respect including termination of all power, control cables, installation of thermistor controller, internal wiring, earthing of LT panels, supply of cable glands etc.complete as per cable schedule, drawings etc. " Item 70.B.180
626 626 "Weight of unit above 100 kg but upto and including 500 kg " Item 70.B.190 12400 KG
627 627 "Weight of unit above 1000 kg but upto and including 3000 kg " Item 70.B.200 2000 KG
628 628 "Weight of unit above 3000 kg but upto and including 6000 kg " Item 70.B.210 14500 KG
629 629 "HT SWITCHBOARD (6.6/11 KV): Erection, Installation including site transportation from owner designated location, testing and commissioning of HT Switch Board consisting of VCB's and other accessories including termination of all LT/control cables, installation on foundation channels, drilling, cutting, welding, aligning, levelling, grouting, assembling and fitting all accessories / instruments / relays, relay coordination, CT, PT, Numerical Relay with basic features like O/C, E/F and additional protections etc., connection of 230 V Supply / battery bank 110 V DC supply, earthing of HT Switchboard, making all the interconnections/ outgoing/incoming LT power & control cable connections including making holes for cable entries as required with materials i.e. WP Cable glands, end lugs, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge Note: Commissioning assistance (Only Supervision) shall be provided by the supplier of the HT Switch Board:- Single VCB panel" Item 70.B.220 1 EA
630 630 "TRANSFORMER :-Installation, testing and commissioning of owner supplied (outdoor type -ONAN cooled) transformer, casting of foundat ion block, & erection of transformer over the rail and foundation channels, including transporting , unpacking, rigging,aligning, le velling, grouting, assembling, fitting and fixing all accessories/instruments/ relays etc. supplied separately if any,etc., making all the interconnections & termination of all power (HT / LT) cables, control cables / busbar etc. as per drawings, including earthi ng/grounding of transformer neutral as per drawing, equipments needed to completely install and commission the transformer Job comp lete in all respect including cost of all labour, tools and materials and all services rendered complete, as per the drawings and di rections of the Site Engineer / engineer-in-Charge. " Item 70.B.230 1 EA
631 631 FLP & WP Distribution Board Erection, installation including within site transportation, testing and commissioning of 415 V , Flame proof distribution boards (FLP-DB) under scope of supply of bidder, assembling as required, installation on the already made foundat ion channels, aligning, levelling, grouting, assembling, making all the inter connections /outgoing/incoming power & control cable/ bus duct connection including making holes for cable entries as required as per drawing, specifications and directions of the Site E ngineer/Engineer-in-Charge including cost of all materials, tools labour etc. complete in all respect including termination of all p ower , control cables, installation of thermistor controller, internal wiring, earthing of FLP-DB panels, supply of cable glands etc .complete as per cable schedule, drawings etc." Item 70.B.240 1600 KG
632 632 "Erection, Installation,Testing & Commissioning of the Owner supplied high mast tower with the help of suitable tools and plants, wi ring of luminaires with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor cores of 1. 5 sq. mm, lugs, MCB and all labour. Scope of work shall include erection & installation of high mast tower, cable connections, erec tion & installation of luminaries & aviation lights, lightning finial, all accessories, cables, etc., erection, foundation casting & grouting of owner supplied FLP feeder pillar, end connection termination & laying of Owner supplied cable from feeder pillar to ba se compartment of high mast complete with all materials and labour as per instruction of Site Engineer/EIC. Earthing works for High Mast tower including construction of earth pits to be operated in relevant separate item:- For 30 M Height High Mast Tower" Item 70.B.250 6 EA
633 633 " Construction of shallow foundation with M20 grade concrete for the highmast considering the safe soil bearing capacity at site as 10 T/sqmtr at 2 metre depth complete with all materials and labour as per instruction of Site Engineer/EIC. Design of foundation sha ll be provided by IOCL. Piling work if required as per soil strata in foundation of high mast is not covered in this scope of work a nd shall be taken up separately:- For 30 M Height High Mast Tower" Item 70.B.260 6 EA
634 634 Installation of corrosion monitoring probes including 2" Flareweld on station piping at desired location and 12 O'Clock position for mounting of ER Probe under the supervision of site engineer. Flareweld assembly shall be supplied by owner. The job complete in all respect with material, tools & tackles, consumables etc. Item 70.B.270 4 EA
635 635 30 COMPOSITE Item 70.C
636 636 "GI CABLE TRAY Supply, installation & fixing of prefabricated perforated GI cable trays of width 150 mm, 300 mm, 450 mm & 600 mm as per site requir ement for laying of cables with standard rung spacings. Load for support span of 2.5 meter as 30, 60, 75 & 90 (in Kg/Mtr) respective ly with concentric static load as 70 Kg at the centre, with materials, labour, tools and tackles, consumables etc , as per drawings , specification and directions of Site Engineer / Engineer-in-Charge" Item 70.C.10 13300 KG
637 637 "SAND FILLING Supplying and spreading of approved quality fine dry river sand in cable trenches including the cost of all material, transport, loa d and lift charges, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge" Item 70.C.20 3800 M3
638 638 "BRICK SOLING Supply and laying of approved quality 75 mm thick second class brick flat soling with sand filling in the interstices, in cable tren ches for protectionincluding the cost of all brick and sand, labour, load and lift charges , tools and tackles etc , as per drawing s, specification and directions of Site Engineer / Engineer-in-Charge" Item 70.C.30 8720 M2
639 639 "CABLE MARKER Supply, erection & installation of MS cable markers, including excavation, installation of the markers, cement concrete grouting, ba ckfilling, materials, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge" Item 70.C.40 697 EA
640 640 "LT Cable joint (1.1 KV): Making straight through joints on Al/Cu conductor XLPE/PVC insulated armoured cable including the supply of required materials such as cable jointing kit (of heat shrinkable sleeve type of Raychem/Mseal/3M) , materials, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge " Item 70.C.50
641 641 Power cables LT : OD upto 20 mm Item 70.C.60 2 EA
642 642 Power cables LT : OD above 20 mm and upto 40 mm Item 70.C.70 2 EA
643 643 Power cables LT : OD above 40 mm and upto 60 mm Item 70.C.80 1 EA
644 644 "HT Cable Termination (6.6/11 KV): Supply, termination and connection of XLPE cable termination kit (indoor type), heat shrinkable sleeve type of Raychem/M-Seal/CCI ma ke with all accessories, including cutting (tools and accessories for termination should meet the selected standards), stripping of cable insulation providing copper cable end lugs and cable glands as required, restoration of insulation, supplying and providing th e cable supporting clamps, straps, cable tags connection to the terminals of HT panel, VFDs, Isolators, transformer, DG etc., earthi ng of armouring, materials, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site En gineer / Engineer-in-Charge:-HT Cable of size upto 3cx240 sq. mm " Item 70.C.90 4 EA
645 645 "EARTH ELECTRODES Supplying, installation, testing of GI earthing electrode, including the supply and installation of the CI cover, charcoal /special backfill etc. and construction of chamber; complete as per drawings,specifications and directions of the Site Engineer, Including the cost of all labour, tools, materials etc. complete in all respects." Item 70.C.100 288 EA
646 646 "EARTHING SYSTEM SET (03 PITS) Supply, installation, testing of earthing system consisting of 3 earth pits of perforated GI pipes earthing electrodes and copper pl ate terminal block including construction of chamber using cement concrete with earthing pit cover and frame, supply of charcoal / / special backfill , salt etc including supply of interconnecting cables / strips including necessary welding etc complete as drawings , specifications and directions of the site engineer/Engineer-in-charge, including cost of tools, materials etc complete in all resp ects as per drawing. The job shall also include testing of each earth pit and the entire earthing system on whole. Note: Earthing for field instruments shall be provided from Station earth grid covered in Electrical SOR." Item 70.C.110 56 SET
647 647 "ACE Chemrod Earthing:Supply, installation, testing and commissioning of ACE (Artificial concept of earthing with chemical rod) Chemrod earthing electrode by digging earthing Item includes the supply and installation of the CI/RCC cover in the earth pit, ba ckfilling etc. and construction of chamber; complete including excavation, backfilling and supply of all materials required for ma king earth pit as per drawings, specifications and directions of the Site Engineer, Including the cost of all labour, tools, materi als etc. complete in all respects. " Item 70.C.120 56 EA
648 648 "EARTHING PLATE Supply & Installation of G.I. earthing plate as per drawing no. 9200-99900-404-009-00 outside the buildings. The item also includes grouting of the plate as shown in the drawing. The item should be complete in all respect including all materials, tools, tackels et c. and as per direction of EIC / Site engineer." Item 70.C.130 74 EA
649 649 "EARTH STRIP / WIRE / ROPE / CABLE Supply, installing and testing of earthing strip/wire/rope/cable for completely making the earthing grid system by supplying, layin g the GI / Cu strip and making all the necessary welding joints, connecting to the earthing electrodes and existing earthing g rid etc., complete as per drawings, specifications and directions of the Site engineer/Engineer-in-charge, including the cost of al l labour, tools, materials, etc. complete in all respect. " Item 70.C.140
650 650 50 mm X 6 mm G.I. earthing strip Item 70.C.150 6600 M
651 651 40 mm X 5 mm G.I. earthing strip Item 70.C.160 280 M
652 652 25mm x 3 mm copper flat Item 70.C.170 425 M
653 653 GI wire (8 SWG) Item 70.C.180 2395 M
654 654 Copper cable as per specifications - 10 Sq.mm Item 70.C.190 650 M
655 655 Copper cable as per specifications - 100 Sq.mm Item 70.C.200 425 M
656 656 Supply, erection & installation of cable conduits made up of GI pipes of medium class 'B' subject to owner's approval in trenches (a lready made), on walls, concrete structure etc., including supply and installation of all the necessary pipe fittings such as bends, sockets, elbows, tees etc., bending, threading, binding, clamping, providings, spacers, plugs, packings, bushings etc., as required Job complete in all respects including the cost of all labour, tools, material etc. and as per specifications and directions of s ite engineer / Engineer-in-Charge. Item 70.C.210
657 657 25 mm Item 70.C.220 548 M
658 658 50 mm Item 70.C.230 1612 M
659 659 100 mm Item 70.C.240 608 M
660 660 "STEEL STRUCTURAL WORKS Supply, fabrication, erection, installation of steel structural works of any type and shape such as cable raks, cable trays, push bu tton control posts etc., as required job complete in all respects including the cost of all labour, tools, material etc., complete. and as per specifications and directions of site engineer/ Engineer-in-Charge. " Item 70.C.250 4020 KG
661 661 "FLAME PROOF FITTINGS : Note: All equipment under this category shall be suitable for location in zone-I gas group IIA & IIB (Temp. class T3) area with a se parate terminal box for incoming cable and a separate terminal box for out going cable (where applicable), apart from separate enclo sure for each equipment including control gear etc. in IP 65 cast aluminium LM-6 certified enclosure. " Item 70.C.260
662 662 FLP/WP PUSH BUTTON STATION :Supply ,erection,testing and commissioning of FLP/WP push button(ON/OFF) control station of approved ma ke with /without ammeter for the motor off control at field including connection and termination of copper control cable, fabricatin g, earthing the supporting structure, painting the same, including supply & installation of double compression cable glands & flame proof plugs for sealing all spare entries including the cost of all labour,tools, materials etc. complete in every respect as per th e specification and directions of the Site Engineer/Engineer-in-charge. Item 70.C.270 3 EA
663 663 "FLP/WP DISTRIBUTION BOARDS : Supply, erection, installation, testing and commissioning of flameproof /weather proof (IP-65) distri bution board as per technical specification of types mentioned for lighting purpose in MLPU / booster shed etc., including connectio n and termination of power cables, earthing wire and conduits etc. including including supply & installation of double compression c able glands & flame proof plugs for sealing all spare entriescomplete as per drawings, specifications and direction of the Site Engi neer, including the cost of all labour, tools, consumable materials etc. complete in all respect. Outdoor Type, floor mounted, flameproof, weatherproof (IP 65) Lighting Distribution board Type-I DB with Bus bar - 100 A TPN, Incom er - 1 no. 63 A TPN MCB & Outgoing - 9 no. 10 A SPN, MCB" Item 70.C.280 1 EA
664 664 "FLP & WP JUNCTION BOX Supply, erection, installation, testing and commissioning of flameproof & weather proof junction box for providing cable terminatio n of motor, including connection and termination of earthing wire and conduits etc., including supply & installation of double compr ession cable glands & flame proof plugs for sealing all spare entries complete as per drawings, specifications and direction of the Site Engineer, including the cost of all labour, tools, consumable materials etc., complete in all respect:- 4 way junction box with 4 cable entries (4 x 3/4"") at bottom & 20 nos. terminals." Item 70.C.290 32 EA
665 665 FLP/WP ROTARY SWITCH : Supply, installation, testing & commissioning of Flame proof weather proof ON/OFF Rotary Switch , IP65, LM6, including including supply & installation of double compression cable glands & flame proof plugs for sealing all spare entries etc., complete in all respects Item 70.C.300 28 EA
666 666 "FLP/WP SWITCH CUM SOCKET : Supply, erection, installation, testing and commissioning of flameproof /weatherproof switch cum socket /welding receptacle of appr oved makes to be installed on walls, coloumns, structures, including supply & installation of double compression cable glands & flam e proof plugs for sealing all spare entries etc., including connection and termination of earthing wire and conduits., etc. complete as per drawings, specifications and direction of the Site Engineer, including the cost of all labour, tools, consumable materials e tc. complete in all respect:- 415V, 63A, Switch & Socket with Plug (No. of Pins 3P +N+ E), Model EPSS 1563-61 of Baliga or Equivalent approved make" Item 70.C.310 4 EA
667 667 "FLP/WP EXHAUST FANS : Flame proof, weather proof, single phase, 12"" exhaust fan, IP65, LM6 type EF1001 of FCG or equivalent alongw ith supporting frame, bolts, louvers, flame proof motor, including supply & installation of double compression cable glands & flame proof plugs for sealing all spare entries, complete in all respects :- FLAMEPROOF EXHAUST FAN,12"", SUITABLE FOR Exd Gas Group II C, as per IS/IEC 60079-2007" Item 70.C.320 30 EA
668 668 FLAMEPROOF TUBELIGHT, 2x22Watt, LED, SUITABLE FOR Exd Gas Group II C, as per IS/IEC 60079-2007 Item 70.C.330 60 EA
669 669 FLAMEPROOF LED FITTING 125W, Ex'd' (Flameproof) Flood Light Fixture, Aluminum (LM 6), Classification:-Zone 1&2, Gas Group:-IIA/IIB, IP 65, T6. Complete with optics, Glass-Toughened Clear Well Glass, Wire Guard: M.S. Epoxy Painted-(White Color) with provision of C able Entries: 2 Nos. x 3/4"" ET, Cable Glands: 2 Nos. x 3/4"" ET (Max. OD 20mm) - Ex'd'(IIA/IIB), DC, Brass Nickel Plated with PVC H ood. Blanking Plug: 1 No. x3/4"" ET - Ex'd', Brass Nickel Plated. Gasket: Neoprene, Hardware: SS 304, Earthing: External 2 Nos. (M6) , Internal 1 No. (M5), Mounting Arrangement: withM.S. Bracket Suitable to Ceiling mounting (With Type 'B' Suspension Bracket / Eye B olt). Finish: Epoxy Powder Coated Grey Shade 631 of IS-5. Item 70.C.340 106 EA
670 670 FLAMEPROOF LED FITTING 60W, Ex'd' (Flameproof) Flood Light Fixture, Aluminum (LM 6), Classification:-Zone 1&2, Gas Group:-IIA/IIB, I P 65, T6. complete with optics, Glass-Toughened Clear Well Glass, Wire Guard: M.S. Epoxy Painted-(White Color) with a provision of Cable Entries: 2 Nos. x 3/4"" ET, Cable Glands: 2 Nos. x 3/4"" ET (Max. OD 20mm) - Ex'd'(IIA/IIB), DC, Brass Nickel Plated with PVC Hood. Blanking Plug: 1 No. x3/4"" ET - Ex'd', Brass Nickel Plated. Gasket: Neoprene, Hardware: SS 304, Earthing: External 2 Nos. (M6 ), Internal 1 No. (M5), Mounting Arrangement: with M.S. Bracket Suitable to Ceiling mounting (With Type 'B' Suspension Bracket / Eye Bolt). Finish: Epoxy Powder Coated Grey Shade 631 of IS-5. Without External reflector" Item 70.C.350 8 EA
671 671 SHOCK TREATMENT CHART :Supply and installation of shock treatment chart framed in good quality glass in English / Hindi / Local Lan guage). Item 70.C.360 108 EA
672 672 CAUTION BOARD :Supply and installation of vitreous enamel caution boards suitable for 440 V/11KV/6.6 KV as per IS 255 including fi xing on the wall with all the required hardware etc. complete in English / Hindi/ Local Language. Item 70.C.370 56 EA
673 673 "STAINLESS STEEL INSCRIPTION PLATE : Supply and installation of approved quality stainless steel name inscription plates including a nodising, engraving the inscriptions, providing screws, etc. for equipments viz. motors, motor control centres, switchgears, push bu tton stations etc. as required, providing necessary holes tapping etc. and fixing the same complete in all respect as per the direction of Site Engineer/Engineer-in-charge including the cost of all labour, tools etc." Item 70.C.380 88 EA
674 674 "PLASTIC INSCRIPTION PLATE : Supply and installation of approved quality plastic name inscription plates including engraving the in scriptions, providing screws, etc. for equipments viz. motors, motor control centres, switchgears, push button stations etc. as requ ired, providing necessary holes tapping etc. and fixing the same complete in all respect as per the direction of Site Engineer/Engineer-in-charge including the cost of all labour, tools etc." Item 70.C.390 88 EA
675 675 "Point wiring Supplying, installation and testing with 1.5 Sq.mm stranded PVC insulated copper conductor wires for phase & neutral of 650V grade i ncluding earthing by providing 1.5 Sq.mm earth insulated continutity wire of copper in PVC conduit (Supply & installation of PVC con duit covered elsewhere in SOR) recessed on wall/ceiling/ false celing including supply & installation of switch boxes,junction boxes , pull boxes, bushes, screws, check nuts, bends, modular switches and sockets . The circuit wiring with 4 Sq.mm PVC copper wire fro m D.B. to switchboard as required is also in the scope of the contractor." Item 70.C.400
676 676 1 light point controlled by 1 switch. Item 70.C.410 180 EA
677 677 2 light points controlled by 1 switch Item 70.C.420 124 EA
678 678 3 light points controlled by 1 switch Item 70.C.430 30 EA
679 679 4 light points controlled by 1 switch Item 70.C.440 2 EA
680 680 Wiring with PVC insulated 2.5 sqmm copper conductor wire for fan points (1 fan point controlled by 1 modular switch) including provi ding space for electronic regulator in switch box , providing and fixing fan hook in the ceiling as per specifications and drawings. Item 70.C.450 98 EA
681 681 "Wiring with PVC insulated 2.5 sqmm copper conductor wire for phase & neutral , 650 V grade including earthing , the third pin with 1.5 sqmm copper conductor earthing insulated continuity wire for exhaust/ wall bracket fan including providing and fixing of 5 pin 6 A modular socket and 10 A modular switch near the door or as as per specifications and drawings. The circuit wiring shall be with 4 sq. mm PVC copper wire from switchboard to 1st exhaust fan for multiple exhaust fans in one circuit. " Item 70.C.460 200 EA
682 682 Wiring for 250 V single phase and neutral 16 amps modular power plug point with PVC insulated 4 sq. mm. copper conductor wires for phase & neutral, 650 V grade including earthing, the third pin with 2.5 sq. mm copper conductor earthing insulated continuity wire, complete with providing and fixing of 6 pin 16/6A modular socket and 20/10 A modular switch (1 plug point per circuit) as per specif ications and drawings Item 70.C.470 124 EA
683 683 "Wiring as in item no. 1 for 250 V single phase and neutral 6 amps modular plug point with PVC insulated 2.5 sq. mm. copper conducto r wires for phase & neutral, 650 V grade including earthing, the third pin with 1.5 sq. mm copper conductor earthing insulated conti nuity wire, complete with providing and fixing of 5 pin 6A modular socket and 10 A modular switch (1 plug point per circuit) as per specifications and drawings. The circuit wiring shall be with 4 sq. mm PVC copper wire from switchboard to 1st plug point for multip le exhaust fans in one circuit. " Item 70.C.480 124 EA
684 684 "Lighting Distribution Board / AC Distribution Board Supply , installation, testing and commissioning of TPN lighting / AC Distribution board of approved make as per appendix -1, with rating and feeders as per specification. The DB shall be of IP-42 protection class and shall conform to IS 8623. The board shall be fitted with an acrylic door as per specifications and drawings " Item 70.C.490
685 685 "Type III Distribution Board : Double Door EURODB of Havells or equivalent approved make having bus bar 200 A TPN, 1 Incomer 125 A FP MCB Isolator with 125 A FP RCCB (Senstivity 100 mA) alongwith 3 numbers 63 A TPN MCB as per specification " Item 70.C.500 28 EA
686 686 Type IV DIstribution Board : Double Door Translucent Euro DB of Havells or approved make as per appendix -1, having 100 A TPN Copper Bus bar, 1x63 A TPN MCB , 1x63 A RCCB (100 mA Sensitivity), 9x6A SP MCB & 6x20 A SP MCB as per specification Item 70.C.510 32 EA
687 687 Type V Distribution Board : Double Door, EURO DB of Havells or equivalent approved make having 200 A TPN Bus Bar, 1 x 100 A FP MCB, 1x100 A FP RCCB (100 mA Sensitivity), 9x32 A SPN Motor duty MCB as per specification Item 70.C.520 5 EA
688 688 Type -VI Light DB:-Euro DB DBOXx of Havells or equivalent make complete with bus bar, neutral links, earth links along with 1 x 6 A MCB SPN , 7x2 A SPN MCB , Digital time switch , 110 - 240 VAC 1 Phase - 2W, 1 C/O, Base/DIN based upon Lat/Long setting of locatio n working according sunrise and sunset and MNX 9-2P Power Contactors 9 A 2 Pole 1 NO or 1 NC of L&T or equivalent Item 70.C.530 26 EA
689 689 Critical Light DB : Euro DB DBOXx of Havells or equivalent make complete with bus bar, neutral links, earth links and 1 x 6 A MCB SP N & 7x2 A SPN MCB Item 70.C.540 2 EA
690 690 "Decorative Light fittings Supply, installation, connection, earthing and testing of the following fittings,including supply and installation of drop pipes, ho oks, fittings, fixtures, nuts,bolts, supports, on walls, outlet box for regulators and all other required materials etc. as per spec ifications, drawings and directions of the Site Engineer including cost of all labour, tools, materials etc. complete in all respect s.Make of the fittings can be the make mentioned in the respective SOR items or equivalent model from the approved make list given i n the specifications." Item 70.C.550
691 691 Supply and fixing of LED wall light cat. no. 35022 9W fitting of PHILLIPS or equivalent approved make complete with all accessories such as LED module, driver, optics, thermal sink, connector blocks etc including installation Item 70.C.560 32 EA
692 692 LED light fittings, Batten with 2XTLED-TMC501-2X TLED-36 W P3242 or equiavlent approved make with LEDs: Supply and fixing of wall mo unted/ suspended type weather proof light 2XTLED-TMC501-2X TLED or equiavlent approved make with LEDs, 36 W or more. LED Fitting of PHILLIPS or equivalent approved make complete with all accessories such as LED module, driver, optics, thermal sink, connector bloc ks etc including installation with LED of approved make. Item 70.C.570 228 EA
693 693 DN170C LED10S-6500 PSU WH:Supply and fixing of surface mounted weather proof light DN170C LED 15 W having 1000 lumens output fittin g of PHILLIPS or equivalent approved make complete with all accessories such as LED module, driver, optics, thermal sink, connector blocks etc including installation. Item 70.C.580 176 EA
694 694 LED light fittings, Recess mounting type, Sereno LED-RC869B LED 30S-6500 PSE W30L120 D8 or equivalent approved make with LEDs: Suppl y and fixing of recess mounted weather proof light Sereno LED-RC869B LED 30S-6500 PSE W30L120 D8 or equiavlent approved make with L EDs, 42 W or more, having 2950 lumens or more output. LED Fitting of PHILLIPS or equivalent approved make complete with all accessor ies such as LED module, driver, optics, thermal sink, connector blocks etc including installation with LED of approved make. Item 70.C.590 28 EA
695 695 "Ceiling fan with electronic regulator & other accessories and fittings etc. of or approved make as per appendix -1 with the followi ng sweep size:- 56"" Sweep" Item 70.C.600 90 EA
696 696 12" Oscillating wall mounted bracket fan, noiseless, plastic moulded construction, rotary device for 3 step speed control integrated unit of approved make with all accessories complete in all respect. Item 70.C.610 4 EA
697 697 Supply, installation, testing and commissioning of swan neck lighting pole of 100mm nominal Diameter B class MS pipe (Height of bot tom of light fitting shall be 2 meters from FGL), having base Plate 200mmx200mmx5mm along with Flameproof (Exd IIA/IIB) and Weather proof 1x60W LED well glass light fitting complete with lamp and builtin control gear of approved make, including supply and installa tion of earthing conductor of 8 SWG GI wire, nuts, bolts, Neck portion of lighting pole shall made up be of 50mm diameter GI pipe(ra dius of neck shall be 250mm). The pole shall be painted with 01 coat of primer and 02 coats of aluminium paint. The job shall also i nclude supply and installation of 4 way Flameproof/weather proof junction box(with 4 cable entries) having minimum 4 Nos., 6A, 440V shrouded terminal, with double compression FLP glands/lugs with looping arrangement and supply and termination of 3C X 2.5 sq. mm. a rmoured copper PVC/XLPE insulated cable from JB to light fitting The job complete in all respects as per specifications, drawings an d instructions of EIC / Site engineer. Item 70.C.620 164 EA
698 698 Supply, installation, testing and commissioning of swan neck lighting pole of 100mm nominal Diameter B class MS pipe (Height of bot tom of light fitting shall be 5 meters from FGL), having base Plate 200mmx200mmx5mm along with Flameproof (Exd IIA/IIB) and Weathe rproof 2x18W LED well glass light fitting complete with lamp and builtin control gear of approved make, including supply and install ation of earthing conductor of 8 SWG GI wire, nuts, bolts, Neck portion of lighting pole shall made up be of 50mm diameter GI pipe(r adius of neck shall be 250mm). The pole shall be painted with 01 coat of primer and 02 coats of aluminium paint. The job shall also include supply and installation of 4 way Flameproof/weather proof junction box(with 4 cable entries) having minimum 4 Nos., 6A, 440V shrouded terminal, with double compression FLP glands/lugs with looping arrangement and supply and termination of 3C X 2.5 sq. mm. armoured copper PVC/XLPE insulated cable from JB to light fitting The job complete in all respects as per specifications, drawings a nd instructions of EIC / Site engineer Item 70.C.630 56 EA
699 699 "Exhaust fan Supply, installation, testing of single phase 230 V, industrial type heavy duty exhaust fan of GEC/Usha/Crompton Greaves or of appro ved make as per appendix -1 fitted/ provided with louvres, supports etc. including making the required opening on walls, fixing and connecting the wires etc. including earthing the body of the fan, making good the opening on the wall etc. complete as per specifica tions, drawings and direction of Site Engineer including the cost of all labour, tools, materials etc. complete." Item 70.C.640
700 700 18" Sweep Item 70.C.650 56 EA
701 701 12" Sweep Item 70.C.660 84 EA
702 702 "PVC Conduit pipes Supply, installation, fixing in position, PVC conduit pipes, of ISI marked , in concrete, brick work etc. during or after constructi on by making grooves in the wall, ceiling etc. cutting threads and jointing the pipes with PVC couplers, providing necessary tees, b ends, junction boxes etc. with 12 SWG GI wire inside conduit without joint for concealed wiring, including making good the concrete, brick work, surfaces etc. complete as per drawings and direction of Site Engineer / Engineer-in-charge including cost of all labour , materials etc." Item 70.C.670
703 703 19 mm Item 70.C.680 2100 M
704 704 25 mm Item 70.C.690 2300 M
705 705 32 mm Item 70.C.700 1150 M
706 706 "Supplying and laying reinforced cement concrete light duty hume pipe, non pressure type (NP3), centrifugally cast conforming to I. S.458 with 1:3:6 concrete casing at joints as required with necessary slope including excavation, backfilling, supply of collars, j ointing of pipes with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement: 2 fine sand), testing of joints, complete in all respects as per specifications, drawing and the direction of the EIC/Site Engineer:- 300 mm dia" Item 70.C.710 37 M
707 707 "Supply, installation and testing of Lightning arrestor on top of the MOV buiding or MOV CP buiding for diverting lightning surges t o the ground. The work shall include supply of 1.2 Meter long copper lightning arrestor with 5 spronged phenyl rod base plate etc. c omplete with necessary insulators including supply and fixing of 50 x 6 mm GI earthing strip of required length and connection to th e main earthing grid . " Item 70.C.720 56 EA
708 708 Supply, installation and commissioning of 415 V, 250A, 50 KA, 4P MCCB with Microprocessor based adjustable type release and terminal spreaders in existing cubicle panel board including drilling holes, cut out in cubicle panel, making connections, etc. The work is to be completed in all respect with disconnection of existing interconnecting cables, dismantling of existing lower rated SFU, if a ny, along with accessories, supply of higher rating interconnecting single core FRLS PVC insulated flexible copper cables (approx. 95 Sqmm), cable termination to MCCB & bus bar with all tools, tackles, consumable materials, labour etc. as per drawings, specifica tion and directions of Site Engineer / Engineer-in-Charge. Item 70.C.730 2 EA
709 709 "Supply fixing and erection of moidular cable transit (MCT) for cable entry to building in proper frame including supply of peelable type, spare block, stay plates compression wedgs etc. with all accessories as per specification considering 20 % minimum spare in e ach module to be installed as per instruction of Engineer in charge/ site engineer :- Galvanised mild steel frame with packing space of Min.120x240 mm with multi diameter blocks and accessories with peeling off arrange ment to adjust cable size from 3.5mm to 99mm outer dia" Item 70.C.740 36 EA
710 710 T&I - Telecom Works - Non ITC Item 00080
711 711 10 SUPPLY Item 80.A
712 712 Supply of 40 mm OD HDPE pipe as per tender specifications Item 80.A.10 308 KMS
713 713 Supply of 89 mm OD, Schedule 80, API 5L Grade-B/ ASTM A106 MS pipe for cable conduit as per tender specifications Item 80.A.20 10916 EA
714 714 T&I - Telecom Works - ITC Item 00090
715 715 10 SUPPLY Item 90.A
716 716 Supply of OFC Jointing kits as per tender specifications Item 90.A.10 168 EA
717 717 Supply of Electronic Marker Locator cum Cable/ Pipe Locator, Fault Locator as per tender specifications Item 90.A.20 3 EA
718 718 Supply of full range (upto 8 feet) RF iD Disk type Electronic Markers as per tender specifications Item 90.A.30 168 EA
719 719 Supply of pre-fabricated printed KM markers for OFC & HDPE as per tender specifications Item 90.A.40 305 EA
720 720 Supply of Joint pit markers for OFC joint locations as per tender specifications Item 90.A.50 168 EA
721 721 Supply of pre-fabricated RCC (1:1.5:3) Joint Box with lid as per tender specifications Item 90.A.60 168 EA
722 722 Supply of RCC Transition pits for building entry points as per tender specifications Item 90.A.70 28 EA
723 723 Supply of wall mounted Fibre Termination Box (FMS) as per tender specifications Item 90.A.80 6 EA
724 724 Supply of OFC Jointing kits as per tender specifications Item 90.A.90 30 EA
725 725 Supply of full range (upto 8 feet) RF iD Disk type Electronic Markers as per tender specifications Item 90.A.100 30 EA
726 726 Supply of 2 Pair unarmoured Telephone Cable as per specifications Item 90.A.110 3000 M
727 727 Supply of 20 Pair Armoured PIJF Underground Telephone Cable as per specifications Item 90.A.120 300 M
728 728 Supply of 5 Pair Armoured PIJF Underground Telephone Cable as per specifications Item 90.A.130 2750 M
729 729 Cat 6 UTP (LAN) Networking Cable as per tender specifications Item 90.A.140 3000 M
730 730 Wall mounted telephone socket outlet with 2 port telephone jack face plate (white/ cream colour) including RJ11 I/O. The item includ es modular plate & switch box/ gang box for fixing the face plate. Item 90.A.150 200 M
731 731 Duplex (2 port) Face plate (Network I/O point) (white/ cream colour) for Local Area Network including RJ45 I/O, modular plate & swit ch box/ gang box for fixing the face plate. Item 90.A.160 150 SET
732 732 Wall mounted Cabinet (switching closet) for housing Networking Equipment/ CCTV hardware, patch panel & accessories including power distribution boxes, MCBs/ Isolator Switches, required installation materials as per tender specifications Item 90.A.170 6 SET
733 733 24 port Industrial Grade Network Switch with Optical Interfaces as per tender specifications Item 90.A.180 6 EA
734 734 Power cable 3 core x 2.5 mm2 Armoured, Copper as per tender specifications Item 90.A.190 1500 M
735 735 600 VA UPS with battery back-up for LAN switch Item 90.A.200 6 EA
736 736 20 SERVICES Item 90.B
737 737 Laying of HDPE pipe (excluding blowing of OFC) in mainline pipe trench at the bottom in all types of soil (including roads, canals, rivers, nullahs, water course crossings, submerged crossings, saltpan areas etc.) including supply and installation of suitable str aps for strapping the HDPE duct with mainline pipe for anti buoyancy, installation of HDPE duct accessories such as plastic couplers , end caps, end plugs, cable sealing plugs, supply and installation of warning tape, consumable guide rods, HDPE jointing, inspectio n of HDPE joints, testing the installed HDPE duct by blowing mandrel with compressed air, pressure testing the HDPE pipe after layi ng as per procedure and performing all work as per drawings, specifications and instruction of the Engineer-in-charge/ Site Engineer and provisions of the contract document for making the duct ready in all respect for OFC blowing. The job includes transportation, loading and unloading of HDPE ducts in nominal length of 1000 meters and duct accessories such as couplers, end caps, end sealing p lugs etc. to various sites along the entire ROW / HDD crossing locations as per specifications and directions of Engineer-in-charge / Site Engineer Item 90.B.10 305 KM
738 738 Laying of HDPE Pipe in trenches/ walls/ concrete structure/ panels etc. as per specifications & drawings & blowing/ laying of Owner supplied Aurmoured/Unarmoured Optical Fibre Cable in HDPE pipe, carrying out end to end testing of laid Optical fibre cables by taki ng OTDR traces and submitting the OTDR trace printouts to Site Engineer/ Engineer-in-charge. The job includes the supply and install ation of required materials such as fixing clamps, screws, tags etc. as required to complete the job in all respects as per drawings and directions of Site Engineer/ Engineer-in-charge including cost of all labour, tools & tackles, test instruments, materials etc. The job includes handing over the tested cables to the Telecom Works Contractor and providing necessary assistance/ support to the Telecom Works Contractor in commissioning of Local Area Network. Item 90.B.20 3000 M
739 739 Trenching for laying of HDPE in Independent trench Excavation in unpaved areas of earth in work sites for conventional cable trenches for a depth upto 1.5 metres including shoring, strutting etc. (if necessary), backfilling the trench, as directed by Engineer-in-charge/ Site Engineer, including all labour and materials complete as per drawings and tender specifications Item 90.B.30 4950 CUM
740 740 Transportation (loading and unloading) of Owner supplied unarmoured Optical fibre cable (OFC) to various sites along Right of Way (R OW), pre laying testing of each cable drum for each fibre and taking the OTDR traces, submission of OTDR traces (in hard as well as soft copy) to Engineer-in-charge/ Site Engineer, blowing of OFC through contractor laid HDPE, jointing / splicing of OFC, post insta llation testing of OFC for each fibre for each drum laid & taking OTDR traces, submission of OTDR traces (in hard as well as soft co py) to Engineer-in-charge/ Site Engineer as per the scope, specifications and directions of Engineer-in-charge/ Site Engineer Item 90.B.40 305 KM
741 741 Installation of OFC jointing kits as per drawings, specifications and directions of Engineer-in-charge/ Site Engineer Item 90.B.50 168 SET
742 742 Installation of RF iD type Electronic Markers as per tender specifications. The job includes configuration & programming of the Elec tronic markers to write information data as per directions of Engineer-in-charge/ Site Engineer. Item 90.B.60 168 SET
743 743 Installation of pre-fabricated printed KM markers for OFC & HDPE as per tender specifications, drawings and directions of Engineer-i n-charge/ Site Engineer Item 90.B.70 305 EA
744 744 Installation of OFC Joint pit markers at every joint location as per specifications, drawings and directions of Engineer-in-charge/ Site Engineer Item 90.B.80 168 EA
745 745 Installation of pre-fabricated RCC (1:1.5:3) Joint Box with lid as per tender specifications, drawings and directions of Engineer-i n-charge/ Site Engineer. Item 90.B.90 168 SET
746 746 Installation of Transition Pits at building entry points as per tender specifications, drawings and directions of Engineer-in-charge / Site Engineer Item 90.B.100 28 SET
747 747 Installation of wall mounted Fibre Termination Box (FMS) as per tender specifications and directions of Engineer-in-charge/ Site Eng ineer Item 90.B.110 6 SET
748 748 Installation of Wall mounted Cabinet (switching closet) for housing Networking Equipment/ CCTV hardware, patch panel & accessories including power distribution boxes, MCBs/ Isolator Switches, required installation materials as per tender specifications Item 90.B.120 6 SET
749 749 30 COMPOSITE Item 90.C
750 750 Supply, erection and installation of GI Pipe of 100 mm nominal bore medium Class B as per IS1239 subject to owner's approval includi ng the supply & installation of all necessary pipe fittings such as bends, sockets, elbows, tees etc. bending, threading, clamping, plugs, packings, bushing etc. as required for sub ducting HDPE duct as per directions of Engineer-in-charge/ Site Engineer including cost of all labour, tools, materials complete in all respects. Item 90.C.10 185 M
751 751 Supply and installation of IDF (intermediate distribution frame) / Distribution box of 20 Pair capacity with mounting arrangement a s per specifications Item 90.C.20 3 EA
752 752 Supply and installation of IDF (intermediate distribution frame) / Distribution box of 10 Pair capacity with mounting arrangements as per specification. Item 90.C.30 3 EA
753 753 Supply and installation of MDF (Main distribution frame) /Distribution box of 50 Pair capacity as per specifications Item 90.C.40 3 EA
754 754 Laying of HDPE conduit and blowing of OFC cable inside the SV/MOV premises along the boundary wall, line item includes supply & ins tallation of suitable clamps , connectors, fixture, corner bends, tools & tackles (comprising of anchor bolts/nuts/accessories etc) required for OFC entry inside SV/MOV loctaionalong the boundary wall by clamping of HDPE conduit at a height of 1 meter above the finished ground level and extending it along the length of boundary wall at 1 meter height upto the transition pit inside SV/RCP bui lding as per attached drawing no. STD-793-00. The line item includes all sevices required for blowing of OFC cable iin HDPE conduit inside the MOV/SV loctaion as per STD - 793 drawing. Item 90.C.50 5000 M
755 755 T&I - Instrumentation Works Item 00100
756 756 10 SUPPLY Item 100.A
757 757 Supply of Pressure Indicators (PI) of the range 0 to 100 Kg / Cm2 as per the technical specifications attached in the Tender. Item 100.A.10 3 EA
758 758 Supply of Pressure Indicators (PI) of the range 0 to 200 Kg / Cm2 as per the technical specifications attached in the Tender. Item 100.A.20 27 EA
759 759 Supply of cable glands - flame proof and weather proof including EP/WP certificates. Glands suitable for 40 C X 1.5sqmm cables. 5/4" Item 100.A.30 58 EA
760 760 Supply of cable glands - flame proof and weather proof including EP/WP certificates. Glands suitable for 12 C X 1.5sqmm cables. 1" Item 100.A.40 58 EA
761 761 Supply of cable glands - flame proof and weather proof including EP/WP certificates. Glands suitable for 4 C X 1.5 sqmm cables. 1/2" Item 100.A.50 58 EA
762 762 Supply of Plugs - flame proof and weather proof including EP/WP certificates. Plugs 5/4" Item 100.A.60 58 EA
763 763 Supply of Plugs - flame proof and weather proof including EP/WP certificates. Plugs 1" Item 100.A.70 58 EA
764 764 Supply of Plugs - flame proof and weather proof including EP/WP certificates. Plugs 1/2" Item 100.A.80 58 EA
765 765 Supply of Reducers- flame proof and weather proof including EP/WP certificates. Reducers 1" to 1/2" Item 100.A.90 58 EA
766 766 Supply of Reducers- flame proof and weather proof including EP/WP certificates. Reducers 1" to 3/4" Item 100.A.100 58 EA
767 767 Fitting, Bushing, 25.4 MM X 12.7 MM NPT(F), Material: Carbon Steel, Manufacturing Process: Forged, Material Specification: A105, End Finish: Threaded, conform to ANSI 16.11 [ SAP code 4323020064] Item 100.A.110 130 EA
768 768 Supply and placing in position 5 mm thick steel checkered plates over cable ducts, valves, pits etc including keeping provision of h oles for lifting arrangement and providing lifting arrangement complete in all respect inclusive of cost of all labour, material, ca rriage etc as per specification & the direction of the engineer in-charge/site engineer Item 100.A.120 55 M2
769 769 Jacking Bracket for 600# & 900#.[ SAP Code 8195999153] Item 100.A.130 1 EA
770 770 Scrapper Detector Switch (8" 600#), Type: Vane, Body Material: Stainless steel, End connection: Flanged, Switch action: DPDT, Voltage:24 VDC, Current: 1A complete as per tender specifications. Item 100.A.140 2 EA
771 771 Scrapper Detector Switch (16" 600#), Type: Vane, Body Material: Stainless steel, End connection: Flanged, Switch action: DPDT, Voltage:24 VDC, Current: 1A complete as per tender specifications. Item 100.A.150 6 EA
772 772 20 SERVICES Item 100.B
773 773 As built documentation for each station covering a) Control /signalling cable layout drawings, b) Cable trench details, c) Cable m arker details, d) Earth grid layout, e) Field instrument termination details, f) Cable schedule, g) Junction box wiring details, h) Earth resistivity measurement data, i) Field panel termination details, j) Calibration data of all instruments tested as per scope. , k) OTDR Traces of the laid OFC as applicable for respective stations Item 100.B.10 29 LS
774 774 30 COMPOSITE Item 100.C
775 775 Installation, testing and commissioning of Pressure Indicator (PI) of various ratings as per drawings, recoomendations of OEM and d irections of Engineer in-charge/ Site engineer Item 100.C.10 12 EA
776 776 INSTALLATION OF PI+PS/PT: Installation, assistance in testing and commissioning of Pressure gauges and Pressure switches (PI+PS) / p ressure Gauge and pressure transmitter (PI+PT) of various ratings as per the directions of Engineer-in-charge/ Site engineer and dra wings Item 100.C.20 17 EA
777 777 INSTALLATION OF PT / PS: Installation, assistance in testing and commissioning of Pressure Transmitter (PT) / Pressure Switch (PS) o f various ratings as per the directions of Engineer in-charge/ Site engineer and drawings. Item 100.C.30 79 EA
778 778 INSTALLATION OF DPT: Installation, assistance in testing and commissioning of Differential Pressure Transmitter (DPT) as per the dir ections of Engineer in-charge/ Site engineer and drawings. Item 100.C.40 6 EA
779 779 INSTALLATION OF TEMPERATURE TRANSMITTER WITH THERMOWELL: Installation and assistance in testing & commissioning of temperature eleme nts/temperature transmitter(TT) by making necessary holes on the pipes, welding the socket for thermowell on the pipe including sup ply of boss, silicon paste etc as per the directions of engineer in-charge/site engineer and drawings. Item 100.C.50 6 EA
780 780 INSTALLATION OF SURFACE MOUNTED TEMPERATURE TRANSMITTER Installation and assistance in testing & commissioning of Surface Mounted te mperature elements/temperature transmitter (TT) by by welding the weld pad on the surface of the pipe, silicon paste as per the dir ections of engineer in-charge/site engineer and drawings. Item 100.C.60 32 EA
781 781 INSTALLATION OF EMERGENCY SHUTDOWN SWITCH: Installation and testing of emergency shut - down (ESD) Push button. This includes mounti ng of termination box as per the drawings, specification and instruction of Engineer in-charge/ Site engineer, replacement of broken glass covers and painting it in red colour. Item 100.C.70 17 EA
782 782 INSTALLATION & TESTING OF SCRAPPER DETECTOR: Installation, assistance in testing and commissioning of Scrapper Detector of various ratings aas per OEM recommandations, vendor drawings, directions of engineer in-charge/site engineer and other approved drawings. Item 100.C.80 8 EA
783 783 FLOW METER INSTALLATION - Taking delivery, shifting to installation site within the station premises, erecting and installing of the flow meter along with reducers and flow meter electronics/ flow transmitter. Providing assistance to control system vendor/meter su pplier in testing and commissioning of the turbine/ ultrasonic / coriolis mass flow meter / clamp on ultrasonic ete etc.. Making str uctural supports and fittings, clamps, screws, nuts, bolts, making the cable supports and terminating cables at panel and field ends . Mounting the junction boxes as per drawings,manufacturer's instructions, specification and direction/instruction of engineer in-ch arge/site engineer. Job shall include termination of cables at both fiels ends and control panel ends, supply of suitable size non-f lame proof cable glands at control panel and the cost of all labour, tools, materials, etc. including labelling, tagging using SS pl ates painting, glanding, ferruling complete in all respect. Item 100.C.90 9 EA
784 784 INSTRUMENTATION JOBS FOR PRESSURE CONTROL VALVE / FLOW CONTROL VALVE - Testing of control valve and field electronics, including fab rication of all structural supports and fittings, termination of related cables at field, panel & MCC end, after loop testing as per vendors drawing and direction of the site engineer. Mounting of junction box if any, supply of non flame proof cable glands for pa neland MCC end. The works includes tagging, labelling, glanding andferruling at both panel and field ends. Item 100.C.100 8 EA
785 785 INSTALLATION OF JUNCTION BOX/ PUSH BUTTON STATION - for MOV/ROSOV: Installation of non-flame proof junction box, explosion proof / flame proof junction boxes, Push button stations for MOV/ROSOV for marshalling of control cables, terminating the cables at field a nd control panel end, mounting the junction boxes/Push button station, connecting to earthing grid by supplying and installing all t he required materials such as supporting structure, canopy, cable gland hood, cement concrete, painting, GI wire etc. (excluding sup ply of the Junction Boxes/Push button station) in all respects complete as per specifications, drawings and direction of site Engine er including supply of suitable size non-flame proof cable glands at Control Panel end and the cost of labour,tools, materials, glan ding, ferruling etc. complete in all respects. Item 100.C.110 139 EA
786 786 INSTRUMENTATION JOBS FOR MOTOR OPERATED VALVES (MOV)/ROSOV/ROV - Carrying out the instrumentation and control system jobs on the alr eady erected actuator assembly of motor operated valves (MOV)by making the necessary cable connection at field and control panel end (excluding the supply of cables) calibrating the control components, adjusting the limit switches, testing the whole assembly as p er drawings specifications and direction of the engineer in-charge/site engineer complete in all respect, including supply of suitab le size non-flame-proof cable glands, ferruls, drilling/cutting of plate for fixing glands at Control Panel end and the cost of all labour, tools, glanding, ferruling, consumables etc. Item 100.C.120 142 EA
787 787 INSTALLATION OF CONTROL PANEL/CONSOLE DESK/ UPS/ RIO/ RTU/ PLC/ ACDB - Taking delivery, shifting the panels to installaion site and erection, installation, testing of Control panels, mounted with all the instruments, power supply units, UPS & battery banks logic control systems , barriers, providing assistance to control system vendor for commissioning of control system including panels, cont rol/console desk etc. installation on already made foundations or fixing on walls, or steel structure or fixtures aligning, levellin g, grouting, inter-wiring outgoing, incoming cable terminations as required, earthing, testing, complete in all respects as per draw ings, specifications and directions of the engineer in-charge/site engineer, including supply of suitable size non-flame proof cable glands for all incoming/outgoing cables and the cost of the materials, tools, labour, glanding, ferruling etc. complete in all resp ects.The indicated quantity is cumulative weight of panels. Item 100.C.130 15500 KG
788 788 STEEL STRUCTURAL WORKS - Supply, fabrication, erection and installation of steel/GI structural works of any type and shape such as c able racks, trays, push button, control posts, ladders, lugs, chain link, fencing, angles, joints, channels, plates, flats, bars etc as required as per specifications, drawings, directions of site engineer/engineer in-charge, inlcuding cost of all labour, material s, tools, consumables etc complete in all respects. Job is inclusuve of taking delivery from owner's go down and shifting to site wh erever required. Item 100.C.140 1280 KG
789 789 Supply & installation of MAGNETIC PROXIMITY SWITCH with suitable junction box for termination of leads/cable for extending contact t o control system for unauthorised entry of building / MOV fencing. Item 100.C.150 50 EA
790 790 AIR CONDITIONER CASSETTE TYPE - Supply & Installation of 1.8T Cassette Type ACs flushed with false ceiling (Daiken / Hitachi / Car rier) along with 5KVA Voltage Stablizer & MS stand for outdoor unit, refregerant piping, drain piping complete as per instruction of EIC / Site Engineer Item 100.C.160 24 SET
791 791 Installation of Manual Call Point (Explosion Proof & Weather Proof) in Hazardous area, terminating the cables at field and control p anel end, connecting to earthing grid by supplying and installing all the required materialssuch as supporting structure, cement con crete, painting, GI wire etc.(excluding supply of the Manual Call Point) complete in all respectsas per specifications. Item 100.C.170 12 EA
792 792 Mechanical - Mainline Item 00110
793 793 10 SERVICES Item 110.A
794 794 "Above Ground Equipments Installation: Taking delivery and transportation of equipments from designated Centralized warehouse location within the state (Details of warehouse given in SCC), placing on pre-constructed foundations, assembling together all sub-assemblies, levelling, alignment, grouting, cleaning and flushing by water, draining, checking, testing, dressing and making good of the foundation and completing the work in all respects in accordance with the relevant drawings, manufacturer's installation instruction, specifications and instructions of Site Engineer / EIC. Note: Weight of equipment is indicative only, Payment shall be done based on actual weight of equipment Item 110.A.10
795 795 Scrapper Launching/Receiving Barrel 16”x 20” 600 Item 110.A.20 6 EA
796 796 Scrapper Launching cum receiving Barrel 8”x 12” 600# Item 110.A.30 2 EA
797 797 "Insulating Coupling Erection: Taking delivery and transportation of equipments from designated Centralized warehouse location within the state (Details of warehouse given in SCC) and installation of Insulating Couplings of the following sizes and pressure class, at elevations specified in the drawing, checking resistance value by meggar test before and afte r erection levelling, aligning and checking, making welded connections to the piping, coating & wrapping and completing the work in all respects in accordance with the relevant drawings, manufacturer's installation instructions, specifications and instructions of Site Engineer / EIC. " Item 110.A.40
798 798 16" Insulating Coupling 600# Item 110.A.50 6 EA
799 799 4" x 600# Insulating Coupling Item 110.A.60 48 EA
800 800 8" x 600# Insulating Coupling Item 110.A.70 2 EA
801 801 "Above ground process piping: Taking delivery & transporting of pipes from designated stock pile location /Designated godown both from outside & inside station premises. Taking delivery of pipe fittings, steel flanges, spiral wound metallic gaskets & fasteners from designated location within station premises, transporting the same to site, fabrication and erection of above ground piping including cutting, edge preparation, bending, threading, lining up, welding and installing pipes and pipe fittings, flanges, elbows, equal and reducing outlet tees ,concentric/eccentric reducers, y-type strainers, drain funnels, vent pipes and tapping for instruments such as pressure gauges, thermal relief valves, thermowells etc., installing above ground at all elevations connecting with equipment nozzles, valves, vessels, in line instruments etc., welded and threaded pipe line of different pressure ratings, flushing pipes by water after cleaning by compressed air, hydrostatic testing of each section to the specified pressure, draining the water, tie-in, final cleaning-up and dispoal of wastes and surpluses including providing all inputs such as labour, material, equipments and consumables necessary to perform the work (other than those specifically under taken by the owner in this contract) and completing the work in all respects in accordance with the drawings, specifications and instructions of Site Engineer / EIC. Thickness and Grade mentioned in the item are for reference only and may vary. Payment shall be based on OD " Item 110.A.80
802 802 4.5" OD x 0.237"WT ASTM A 106 Gr B/A333 Item 110.A.90 780 M
803 803 2.375" OD x 0.218"WT ASTM A 106 Gr B /A333 Item 110.A.100 300 M
804 804 1.315" OD x 0.179"WT ASTM A 106 Gr B /A333 Item 110.A.110 40 M
805 805 "Under ground piping for Process piping (with PU/3LPE Coating): Taking delivery of bare Pipes, pipe fittings, steel flanges, spiral wound metallic gaskets & fasteners from designated location with in station premises transporting the same to site, fabrication and erection of underground piping including cutting, edge preparatio n, bending, threading, lining up and welding, excavating, trenching in all kind of soil to specific depths as indicated in drawings and installing pipes and all types of pipe fittings like flanges, elbows, equal and reducing outlet tees, concentric/eccentric reduc ers, drain funnels, vent pipe and tapping for instrument such as pessure gauges, thermal relief valves, thermowells etc., undergroun d at elevations indicated in the drawing connecting with equipment nozzles, valves, vessels, in-line instruments etc.,Cleaning expos ed steel surfaces of Bare Pipes, Pipe Joints, Fittings, Flanges,equipment and valves etc. by sand blasting or with power wire brush (wherever sand blast cleaning is not possible) free of dust, grease, mill scales etc. and applying single layer polyurethane coatin g(PU) using 100% solvent free elastomeric plyurethane/ liquid epoxy, with approved materials,Equipment etc, holiday detection of the coating, cleaning of coated pipes by water flushing after cleaning by compresed air,hydrostatic testing of each section to the spec ified pressure, draining the water, tie-in, back filling, restoration of site final cleaning up and disposal of water and surpluses, providing all inputs such as labour, materials equipment and consumable necessary to perform the work (other than those specificall y undertaken to be supplied by the owner under the contract) and completing the work in all respects in accordance with the drawing s, specifications and instructions of the Site Engineer / EIC. In case of 3LPE coated pipes, weld joints shall be PU coated.Thicknes s and Grade mentioned in the item are for reference only and may vary. Payment shall be based on OD Note:- Charges for applying single layer polyurethane coating(PU) using 100% solvent free elastomeric plyurethane/ liquid epoxy for exposed steel surfaces of Bare Pipes, Pipe Joints, Fittings, Flanges,equipment and valves etc shall be paid under separate SOR Item. " Item 110.A.120
806 806 4.5" OD x 0.237"WT ASTM A 106 Gr B/A333 -U/G Item 110.A.130 40 M
807 807 2.375" OD x 0.218"WT ASTM A 106 Gr B/A333 -U/G Item 110.A.140 40 M
808 808 "Valves: Taking delivery of valves of all types and pressure rating from the designated Centralized warehouse location within the st ate (Details of warehouse given in SCC), transporting the same to site, erecting above ground on preconstructed foundations or nder ground including earth work in excavation and filling for under ground valves at elevations specified in the drawings, priming and painting of above ground valves, PU Painting of under ground portions (if applicab le) including all inputs, labour, material and consumable (other than those specifically undertaken to be supplied by the owner) and completing the work in all respects in accordance with the drawings, manufacturer's installation instructions and specifications and instructions of the Site Engineer / EIC. " Item 110.A.150
809 809 8" x ANSI 600# MOV F/F API 6D Ball Valve Item 110.A.160 2 EA
810 810 16"x 600 # MOV W/W U/G API 6D Ball Valve Item 110.A.170 6 EA
811 811 16"x 600# MOV F/F A/G API 6D Ball Valve Item 110.A.180 30 EA
812 812 16" x ANSI 600# HOV F/F A/G API 6D Ball Valve Item 110.A.190 6 EA
813 813 4" x ANSI 600# HOV F/F A/G API 6D Ball Valve Item 110.A.200 80 EA
814 814 4"x 600 # HOV W/W U/G extended stem API 6D Ball Valve Item 110.A.210 64 EA
815 815 8" W/W ANSI 600# U/G, API6D BALL VALVE MOV Item 110.A.220 2 EA
816 816 8" x ANSI 600# HOV F/F A/G API 6D Ball Valve Item 110.A.230 2 EA
817 817 "Valves: Taking delivery of valves of all types and pressure rating from the designated location within station premises / Centralized warehouse (as applicable), transporting the same to site, erecting above ground on preconstructed fou ndations or underground including earth work in excavation and filling for under ground valves at elevations specified in the drawin gs, priming and painting of above ground valves, PU Painting of under ground portions (if applicable) including all inputs, labour, material and consumable (other than those specifically undertaken to be supplied by the owner) and completing the work in all respec ts in accordance with the drawings, manufacturer's installation instructions and specifications and instructions of the Site Enginee r / EIC. " Item 110.A.240
818 818 2" x ANSI 600# HOV F/F API 6D Ball Valve Item 110.A.250 152 EA
819 819 2" x ANSI 600# HOV W/W API 6D Ball Valve Item 110.A.260 64 EA
820 820 1" x ANSI 800# HOV W/W BS 5351 BALL VALVE Item 110.A.270 72 EA
821 821 "Valves: Taking delivery of valves of all types and pressure rating from the designated location within station premises / Centralized warehouse (as applicable), transporting the same to site, erecting above ground on preconstructed fou ndations or underground including earth work in excavation and filling for under ground valves at elevations specified in the drawin gs, priming and painting of above ground valves, PU Painting of under ground portions (if applicable) including all inputs, labour, material and consumable (other than those specifically undertaken to be supplied by the owner) and completing the work in all respec ts in accordance with the drawings, manufacturer's installation instructions and specifications and instructions of the Site Enginee r / EIC.- Globe valve " Item 110.A.280
822 822 4"x ANSI 600# F/F BS-1873/BS EN ISO 15761 GLOBE Valve Item 110.A.290 56 EA
823 823 2"x ANSI 600# F/F BS-1873 GLOBE Valve Item 110.A.300 8 EA
824 824 1"x ANSI 800# W/W BS-1873/BS EN ISO 15761 GLOBE Valve Item 110.A.310 18 EA
825 825 "Radiographic Inspection: Inspection of welding by radiographic method on all types of piping including processing of films and interpreting the results of we ld quality and reporting the same to the Site Engineer together with recommendations as to the acceptability or otherwise of the wel ds, submitting the finished radiographic films as may be approved or directed by Engineer-in-Charge inclusive of supply of all peson nel, labour, materials, equipment, consumable, inputs, etc. and providing all services complete in all respects as envisaged in the contract documents. Note: i) Payment will be on the basis of number of welds of the respective size radiographed and shall be all inclusive for the complete job of radiographic inspection as envisaged in the contract document. ii) Radiography not involving full girth weld will be paid at 50% of the rate for full girth weld for the respective size. iii) For set-on type branch welding, the rate for radiography will be as applicable to the branch pipe size. iv) Repeat radiography of individual welds due to defective films or repair of welds shall be done at contractor's cost. In case where radiography is not possible: v) Verification by utrasonic testing shall be done at contractors cost. vi) Magenetic particle inspection as and where required shall be done at Contractors cost. " Item 110.A.320
826 826 4" NB Pipe Joints RT Item 110.A.330 728 EA
827 827 2" NB Pipe Joints RT Item 110.A.340 416 EA
828 828 1" NB Pipe Joints RT Item 110.A.350 40 EA
829 829 "Dismantling of Structures: Dismantling by opening joints or by gas cutting/ cold cutting (wherever required as per site condition) of existing steel structural such as support for pipes, pipe fittings, valves, plate forms, walkways, stairways etc. including excav ation work wherever required handling, loading into truck for purpose of weighing, shifting to the designated location within the station premises and handing over, completing the work in all respect as per drawings, instructio n of the Site Engineer / EIC. " Item 110.A.360 6 TO
830 830 Temporary Barricading: Providing Temporary Barricading made of GI/ steel sheet with angle iron frame (40x40x6) in panels of 1.5 to 2 .0m including lateral/ vertical angle bracing/ steel beam at bottom for stability, earth filling up to 300mm height above Item 110.A.370 600 SQM
831 831 20 COMPOSITE Item 110.B
832 832 Supply and Erection of Structural Steel: Supplying at site, steel structural items such as steel plates, bars, MS gratings, chequere d plates, angles, beams channels, commercial quality heavy pipes, C.I. Rollers, bolts & nuts, washers, grouting bolts, padding plate s etc., fabrication and erection of saddle supports and other type of supports for pipes manifolds and valves, fabrication and erect ion of platforms walkways, stairways etc., sand blast/ power brush cleaning, priming and painting the finished structures including supply of all other inputs such as labour, materials, consumable etc. necessary to perform and complete the work in all respect, in accordance with drawings, specifications and instructions of the Site Engineer / EIC. Item 110.B.10 32 TO
833 833 Painting: Cleaning exposed steel surfaces of piping, equipment and valves etc. by abrasive blasting or with power wire brush (wherev er abrasive blast cleaning is not possible) free of dust, grease, mill scales etc. priming with one coat of primer and painting the surfaces with two coats as per specification, with approved materials, paints, brushes, labour, equipment etc. and completing the jo b in all respects as per specification and instructions of the Site Engineer / EIC. All materials including supply of paint are in t he scope of contractor. Item 110.B.20
834 834 Zinc Ethyl Slicate Primer Item 110.B.30 690 SQM
835 835 High Build EPOXY MIO Item 110.B.40 690 SQM
836 836 Isocynate Aliphatic Poly Urethene(PU) Item 110.B.50 690 SQM
837 837 "PU /liquid epoxy Coating of under ground piping: Cleaning exposed steel surfaces of piping, equipment and valves etc. by sand blasting or with power wire brush (wherever sand blast cleaning is not possible) free of dust, grease, mill scales etc. and applying single layer polyurethane coating(PU) using 100% Solvent free elastomeric polyurethane/ liquid epoxy, with approved materials, labour, equipment etc. and completing the job in all respects as per specification and instructions of the Site Engineer / EIC. " Item 110.B.60 180 M2
838 838 "Copper Strips/ Flats for Jumpers for Flanged Joints of the Product Process Piping: Supply and Installation of one copper jumper per flanged joint across the flanged joints for valves, spool piece, branch offs etc., of product process piping, The job includes cutt ing drilling of holes of required size in the copper strips/ flats for bolting purpose and complete the works in all respects as per specifications & drawings and instructions of Site Engineer/ EIC. Note: Copper jumpers shall be installed in all the flanged joints of Product Process piping only and not in fire water lines. " Item 110.B.70
839 839 Up to 30 mm wide x 3 mm thick Copper strip Item 110.B.80 368 EA
840 840 30 - 50 mm wide x 3 mm thick Copper strip Item 110.B.90 80 EA
841 841 30 SUPPLY Item 110.C
842 842 Supply and delivery of Spiral Wound Metallic Gaskets at respective stations as per Station wise Break up of material supply and as p er technical specifications from approved vendors specified in tender document Item 110.C.10
843 843 16" SWMG ANSI 600# Item 110.C.20 26 EA
844 844 14" SWMG ANSI 600# Item 110.C.30 12 EA
845 845 8" SWMG ANSI 600# Item 110.C.40 20 EA
846 846 6" SWMG ANSI 600# Item 110.C.50 4 EA
847 847 4" SWMG ANSI 600# Item 110.C.60 280 EA
848 848 3" SWMG ANSI 600# Item 110.C.70 8 EA
849 849 2" SWMG ANSI 600# Item 110.C.80 324 EA
850 850 1" SWMG ANSI 600# Item 110.C.90 28 EA
851 851 Supply and delivery of Steel Fasteners at respective stations as per Station wise Break up of material supply and as per technical s pecifications from approved vendors specified in tender document. Item 110.C.100
852 852 Fasteners for Flanges 16" x 600# (1.500" Dia. X 11.00" Length ) Item 110.C.110 288 EA
853 853 Fasteners for Flanges 16" x 600# (1.500" Dia. X 13.75" Length )-extended stud length for flanges with spectacle blind Item 110.C.120 148 EA
854 854 Fasteners for Flanges 14" x 600# (1.375" Dia. X 10.25" Length ) Item 110.C.130 96 EA
855 855 Fasteners for Flanges 8" x 600# (1.125" Dia. X 10" Length) - extended stud length for flanges with spectacle blind Item 110.C.140 32 EA
856 856 Fasteners for Flanges 8" x 600# (1.125" Dia. X 8.25" Length ) Item 110.C.150 192 EA
857 857 Fasteners for Flanges 6" x 600# (1.000" Dia. X 7.50" Length ) Item 110.C.160 32 EA
858 858 Fasteners for Flanges 4" x 600# ( 0.875" Dia. X 7.75" Length ) - extended stud length for flanges with spectacle blind Item 110.C.170 212 EA
859 859 Fasteners for Flanges 4" x 600# (0.875" Dia. X 6.50" Length ) Item 110.C.180 1864 EA
860 860 Fasteners for Flanges 2" x 600# ( 0.625" Dia. X 5.75" Length ) - extended stud length for flanges with spectacle blind Item 110.C.190 80 EA
861 861 Fasteners for Flanges 2" x 600# (0.625" Dia. X 4.75" Length ) Item 110.C.200 2496 EA
862 862 Fasteners for Flanges 1" x 600# (0.625" Dia. X 4.00" Length ) Item 110.C.210 160 EA
863 863 Supply and delivery of Steel Flanges at respective stations as per Station wise Break up of material supply and as per technical spe cifications from approved vendors specified in tender document: Item 110.C.220
864 864 16", WNRF FLANGE, ANSI - 600# (B 16.5) Item 110.C.230 18 EA
865 865 14", WNRF FLANGE, ANSI - 600# (B 16.5) Item 110.C.240 12 EA
866 866 8", WNRF FLANGE, ANSI - 600# (B 16.5) Item 110.C.250 10 EA
867 867 6", WNRF FLANGE, ANSI - 600# (B 16.5) Item 110.C.260 4 EA
868 868 4", WNRF FLANGE, ANSI - 600# (B 16.5) Item 110.C.270 153 EA
869 869 2", WNRF FLANGE, ANSI - 600# (B 16.5) Item 110.C.280 224 EA
870 870 1", WNRF FLANGE, ANSI - 600# (B 16.5) Item 110.C.290 36 EA
871 871 16", BLRF FLANGE, ANSI - 600# (B 16.5) Item 110.C.300 6 EA
872 872 14", BLRF FLANGE, ANSI - 600# (B 16.5) Item 110.C.310 6 EA
873 873 8", BLRF FLANGE, ANSI - 600# (B 16.5) Item 110.C.320 8 EA
874 874 6", BLRF FLANGE, ANSI - 600# (B 16.5) Item 110.C.330 2 EA
875 875 4", BLRF FLANGE, ANSI - 600# (B 16.5) Item 110.C.340 42 EA
876 876 3", BLRF FLANGE, ANSI - 600# (B 16.5) Item 110.C.350 2 EA
877 877 2", BLRF FLANGE, ANSI - 600# (B 16.5) Item 110.C.360 120 EA
878 878 1", BLRF FLANGE, ANSI - 600# (B 16.5) Item 110.C.370 36 EA
879 879 Supply and delivery of following mentioned Spectacle Blinds at respective stations as per Station wise Break up of material supply a nd as per technical specifications indicated in tender documents (As per ASME B16.48) Item 110.C.380
880 880 16" Spectacle Blind 600# F/F A/G - ASTM A105 Item 110.C.390 6 EA
881 881 8" Spectacle Blind 600# F/F A/G - ASTM A105 Item 110.C.400 2 EA
882 882 4" Spectacle Blind 600# F/F A/G - ASTM A350 LF2 Item 110.C.410 24 EA
883 883 2" Spectacle Blind 600# F/F A/G - ASTM A350 LF2 Item 110.C.420 8 EA
884 884 Supply and delivery of pipe fittings at respective stations as per Station wise Break up of material supply and as per technical sp ecifications from approved vendors specified in tender document Item 110.C.430
885 885 16"x14” x 600# Unequal tee Item 110.C.440 6 EA
886 886 8"x6" 600# Unequal Tee Item 110.C.450 2 EA
887 887 8"x4" 600# Unequal Tee Item 110.C.460 4 EA
888 888 4"x2" 600# Unequal Tee Item 110.C.470 96 EA
889 889 4" 600# Equal Tee Item 110.C.480 32 EA
890 890 1" ANSI 600# Equal Tee Item 110.C.490 8 EA
891 891 4" ANSI 600# 90 deg LR Bends Item 110.C.500 140 EA
892 892 2" ANSI 600# 90 deg LR Bends Item 110.C.510 20 EA
893 893 1" ANSI 600# 90 deg LR Bends Item 110.C.520 20 EA
894 894 8" ANSI 600# 45 deg LR Bends Item 110.C.530 1 EA
895 895 1" size 3000# St. NIPPLE Item 110.C.540 40 EA
896 896 1" 3000# HALF COUPLING Item 110.C.550 40 EA
897 897 16"x4" x 600# Weld-o-let Item 110.C.560 66 EA
898 898 16"x2" x 600# Weld-o-let Item 110.C.570 66 EA
899 899 8"x2" x 600# Weld-o-let Item 110.C.580 10 EA
900 900 Supply of ASTM A106 Gr.B /A333 pipes at respective stations as per Station wise Break up of material supply and as per technical sp ecifications from approved vendors specified in tender document. Item 110.C.590
901 901 4.500" ODx 0.237" WT (Sch.STD) ASTM A 333 Gr 6 bare Pipe Item 110.C.600 800 M
902 902 2.375" ODx 0.218" WT (Sch.XS) ASTM A 333 Gr 6 bare pipe Item 110.C.610 320 M
903 903 1.315" ODx 0.179"WT (Sch.XS) ASTM A 333 Gr 6 Bare pipe Item 110.C.620 40 M
904 904 " Supply of Valves at respective stations as per technical specifications from approved vendors in the tender document - Globe valves " Item 110.C.630
905 905 4"x ANSI 600# F/F BS-1873 GLOBE Valve Item 110.C.640 56 EA
906 906 4"x ANSI 600# F/F BS-1873 GLOBE Valve Item 110.C.650 8 EA
907 907 Supply and delivery of BS 5351/ISO 17292 Ball valve for use in process piping at respective stations as per Station wise Break up o f material supply and as per technical specifications from approved vendors specified in tender document. 1" x 800# Ball valve HOV W /W ISO 17292 Item 110.C.660 72 EA
908 908 Supply and delivery of API 6D Ball valves for use in process piping at respective stations as per Station wise Break up of material supply and as per technical specifications from approved vendors specified in tender document. Item 110.C.670
909 909 2" W/W ANSI 600# A/G, API6D BALL VALVE HOV Item 110.C.680 160 EA
910 910 2" F/F ANSI 600# A/G, API6D BALL VALVE HOV Item 110.C.690 56 EA
911 911 4" F/F ANSI 600# A/G, API6D BALL VALVE HOV Item 110.C.700 9 EA
912 912 4"x 600 # HOV W/W U/G EXTENDED STEM, API6D BALL VALVE HOV Item 110.C.710 13 EA
913 913 Mechanical - CSW Item 00120
914 914 10 SERVICES Item 120.A
915 915 Equipment installation Item 120.A.10
916 916 Vertical Submersible type Motor Driven Water filling Pumping Unit_A.i.8 Item 120.A.20 2 TO
917 917 "Motor Driven F/F Jockey Pump Unit Installation: Taking delivery of motor driven Fire Fighting Pumping unit from designated storage location within the pump station, shifting and placing the equipments on the pre-constructed foundation, levelling, grouting and aligning the equipment, assembling together of all sub-assemblies, auxiliaries, mountings, fittings, interconnecting piping etc., carrying out trial run of complete unit, making fina l alignment, checking and testing of the complete unit and completing the work in all respects in accordance with the specification, drawings, manufacturer's installation instructions, technical specifications and as per the instruction of the Site Engineer / EIC. Note: 1. The auxiliaries and mountings shall include but not limited to pipe works etc. 2. Electrical & Instrumentation connections are not included in this item. Jockey Pump Unit _A.i.9" Item 120.A.30 1 TO
918 918 "Engine Driven F/F Pumping Units Installation: Taking delivery of engine driven Fire Fighting Pumping unit from designated storage location within the pump station, shifting and placing the equipments on the pre-constructed foundation, levelling, grouting and aligning the equipment, assembling together of al l sub-assemblies, auxiliaries, mountings, fittings, interconnecting piping etc., carrying out trial run of complete unit, making fin al alignment, checking and testing of the complete unit and completing the work in all respects in accordance with the specification , drawings, manufacturer's installation instructions, technical specifications and as per the instruction of the Site Engineer / EIC . Note: 1. The auxiliaries and mountings shall include but not limited to pipe works etc. 2. Electrical & Instrumentation connections are not included in this item. Fire fighting Pumping Unit _A.ii.1" Item 120.A.40 7.5 TO
919 919 "Insulating Coupling Erection: Taking delivery and transportation of equipments from designated Centralized warehouse location within the state (Details of warehouse given in SCC) and installation of Insulating Couplings of the following sizes and pressure class, at elevations specified in the drawing, checking resistance value by meggar test before and afte r erection levelling, aligning and checking, making welded connections to the piping, coating & wrapping and completing the work in all respects in accordance with the relevant drawings, manufacturer's installation instructions, specifications and instructions of Site Engineer / EIC. " Item 120.A.50
920 920 8" x 600# Insulating Coupling Item 120.A.60 1 EA
921 921 6" x 300# Insulating Coupling Item 120.A.70 1 EA
922 922 "Above Ground Equipments Installation: Taking delivery and transportation of equipments from designated Centralized warehouse locati on within the state (Details of warehouse given in SCC), placing on pre-constructed foundations, assembling together all sub-assembl ies, levelling, alignment, grouting, cleaning and flushing by water, draining, checking, testing, dressing and making good of the foundation and completing the work in all respects in accordance with the relevant drawings, manufacturer's insta llation instruction, specifications and instructions of Site Engineer / EIC. Note: Weight of equipment is indicative only, Payment shall be done based on actual weight of equipment " Item 120.A.80
923 923 Single Basket Type Strainer - 14" x14"-600# Item 120.A.90 6 TO
924 924 Single Basket Type Strainer - 12" x 600# Item 120.A.100 4 TO
925 925 Single Basket Type Strainer - 6" x 600#" Item 120.A.110 1.8 TO
926 926 "Above Ground Equipments Installation: Taking delivery of equipments, shifting/transporting within station premises, placing on pre-constructed foundations, assembling to gether all sub-assemblies, levelling, alignment, grouting, cleaning and flushing by water, draining, checking, testing, dressing and making good of the foundation and completing the work in all respects in accordance with the relevant drawings, manufacturer's ins tallation instruction, specifications and instructions of Site Engineer / EIC. Note: Weight of equipment is indicative only, Payment shall be done based on actual weight of equipment " Item 120.A.120
927 927 Y - Type Strainer - 10" x10"- 150# Item 120.A.130 2 TO
928 928 Y - Type Strainer -3" X3"X150#/ 4" x4"- 150# Item 120.A.140 2 TO
929 929 "Above ground process piping: Taking delivery & transporting of pipes from designated stock pile location /Designated godown both from outside & inside station pr emises. Taking delivery of pipe fittings, steel flanges, spiral wound metallic gaskets & fasteners from designated location within s tation premises, transporting the same to site, fabrication and erection of above ground piping including cutting, edge preparation, bending, threading, lining up, welding and installing pipes and pipe fittings, flanges, elbows, equal and reducing outlet tees,conc entric/eccentric reducers, y-type strainers, drain funnels, vent pipes and tapping for instruments such as pressure gauges, thermal relief valves, thermowells etc., installing above ground at all elevations connecting with equipment nozzles, valves, vessels, in li ne instruments etc., welded and threaded pipe line of different pressure ratings, flushing pipes by water after cleaning by compress ed air, hydrostatic testing of each section to the specified pressure, draining the water, tie-in, final cleaning-up and dispoal of wastes and surpluses including providing all inputs such as labour, material, equipments and consumables necessary to perform the wo rk (other than those specifically under taken by the owner in this contract) and completing the work in all respects in accordance w ith the drawings, specifications and instructions of Site Engineer / EIC. Thickness and Grade mentioned in the item are for referenc e only and may vary. Payment shall be based on OD " Item 120.A.150
930 930 14" OD x 0.375"WT API 5L Item 120.A.160 190 M
931 931 12.75" OD x 0.375" WT APL 5L Item 120.A.170 190 M
932 932 10.75" OD x 0.365" APL 5L Item 120.A.180 40 M
933 933 8.625" OD x 0.322" / 0.375" / 0.438" WT API 5L /ASTM A106/A333 Item 120.A.190 420 M
934 934 6.625" OD x 0.280" ASTM A 106 Pipe/A333 Item 120.A.200 360 M
935 935 4.5" OD x 0.237"WT ASTM A 106 Gr B/A333 Item 120.A.210 67 M
936 936 3.5" OD x 0.216"WT ASTM A 106 Gr B /A333 Item 120.A.220 280 M
937 937 2.375" OD x 0.218"WT ASTM A 106 Gr B /A333 Item 120.A.230 204 M
938 938 1.315" OD x 0.179"WT ASTM A 106 Gr B /A333 Item 120.A.240 260 M
939 939 "Above ground internal epoxy coated pipe for Fire Water Services: (with internal epoxy coating for repair at welding joints ) Taking delivery of internal epoxy coated pipes, pipe fittings, steel flanges, spiral wound metallic gaskets & fasteners from designated location within station premises / Centralized warehouse (as appl icable), transporting the same to site, fabrication and erection of above ground piping including cutting, edge preparation, bending , threading, lining up, welding and installing pipes and pipe fittings, flanges, elbows, equal and reducing outlet tees, concentric/eccentric reducers, y-type strainers, drain funnels, vent pipes and tapping for instruments such as pressure gauges, thermal relief valves, thermowells etc., installing above ground at all elevations connecting w ith equipment nozzles, valves, vessels, in line instruments etc., welded and threaded pipe line of different pressure ratings, flush ing pipes by water after cleaning by compressed air, hydrostatic testing of each section to the specified pressure, draining the wat er, tie-in, final cleaning-up and disposal of wastes and surpluses including providing all inputs such as labour, material, equipments and consumables necessary to perform the work (other than those specifically under t aken by the owner in this contract).The scope shall also include cleaning of internal surface of pipes conforming to SSPCSP-10 at al l location where coating has been destroyed due to welding and repairing the internal surface by application of 2-pack cold cured Is ophthalic polyster acrylic co-polymer glass flake filled /Liquid epoxy / Equivalent with coating of thickness 700-1000 Microns . The locations where internal coating repair is expected would be at pipe end , Flanges ,pipe fittings ,valve location so that the internal of pipe surface is not directly exposed to water and completing the wo rk in all respects in accordance with the drawings, specifications and instructions of Site Engineer / EIC. " Item 120.A.250
940 940 14" ODx 0.375" WT IS3589 FE410 Pipe Item 120.A.260 40 M
941 941 12.75" ODx 0.250" WT IS3589 FE410 Pipe Item 120.A.270 1140 M
942 942 10.75" ODx 0.250" WT IS3589 FE410 Pipe Item 120.A.280 40 M
943 943 8.625" ODx 0.250" WT IS3589 FE410 Pipe Item 120.A.290 40 M
944 944 6.625" ODx 0.250" WT IS3589 FE410 Pipe Item 120.A.300 40 M
945 945 4.5" ODx 0.237" WT ASTM A 106 Gr B Pipe FW Item 120.A.310 102 M
946 946 3.5" OD x 0.216"WT ASTM A 106 Gr B FW Item 120.A.320 32 M
947 947 2.375" OD x 0.218"WT ASTM A 106 Gr B -FW Item 120.A.330 16 M
948 948 1.315" OD x 0.179"WT ASTM A 106 Gr B -FW Item 120.A.340 8 M
949 949 "Under ground piping for Process piping (with PU/3LPE Coating): Taking delivery of bare Pipes, pipe fittings, steel flanges, spiral wound metallic gaskets & fasteners from designated location with in station premises transporting the same to site, fabrication and erection of underground piping including cutting, edge preparatio n, bending, threading, lining up and welding, excavating, trenching in all kind of soil to specific depths as indicated in drawings and installing pipes and all types of pipe fittings like flanges, elbows, equal and reducing outlet tees, concentric/eccentric reduc ers, drain funnels, vent pipe and tapping for instrument such as pessure gauges, thermal relief valves, thermowells etc., undergroun d at elevations indicated in the drawing connecting with equipment nozzles, valves, vessels, in-line instruments etc.,Cleaning expos ed steel surfaces of Bare Pipes, Pipe Joints, Fittings, Flanges,equipment and valves etc. by sand blasting or with power wire brush (wherever sand blast cleaning is not possible) free of dust, grease, mill scales etc. and applying single layer polyurethane coatin g(PU) using 100% solvent free elastomeric plyurethane/ liquid epoxy, with approved materials,Equipment etc, holiday detection of the coating, cleaning of coated pipes by water flushing after cleaning by compresed air,hydrostatic testing of each section to the spec ified pressure, draining the water, tie-in, back filling, restoration of site final cleaning up and disposal of water and surpluses, providing all inputs such as labour, materials equipment and consumable necessary to perform the work (other than those specificall y undertaken to be supplied by the owner under the contract) and completing the work in all respects in accordance with the drawing s, specifications and instructions of the Site Engineer / EIC. In case of 3LPE coated pipes, weld joints shall be PU coated.Thicknes s and Grade mentioned in the item are for reference only and may vary. Payment shall be based on OD Note:- Charges for applying single layer polyurethane coating(PU) using 100% solvent free elastomeric plyurethane/ liquid epoxy for exposed steel surfaces of Bare Pipes, Pipe Joints, Fittings, Flanges,equipment and valves etc shall be paid under separate SOR Item. " Item 120.A.350
950 950 14" OD x 0.375"WT APL 5L -U/G Item 120.A.360 60 M
951 951 12.75" OD x 0.375" WT APL 5L -U/G Item 120.A.370 60 M
952 952 10.75" OD x 0.365" APL 5L -U/G Item 120.A.380 10 M
953 953 8.625" OD x 0.322" / 0.375" / 0.438" WT API 5L /ASTM A106/A333 -U/G Item 120.A.390 90 M
954 954 6.625" OD x 0.280" ASTM A 106 Gr B/A333 Pipe -U/G Item 120.A.400 25 M
955 955 4.5" OD x 0.237"WT ASTM A 106 Gr B/A333 -U/G Item 120.A.410 31 M
956 956 3.5" OD x 0.216"WT ASTM A 106 Gr B/A333 -U/G Item 120.A.420 80 M
957 957 2.375" OD x 0.218"WT ASTM A 106 Gr B/A333 -U/G Item 120.A.430 76 M
958 958 1.315" OD x 0.179"WT ASTM A 106 Gr B/A333 -U/G Item 120.A.440 64 M
959 959 "Under ground piping for Fire Water Services:(with internal epoxy coating for repair at welding joints, flanges and fittings) Taking delivery of bare Pipes, pipe fittings, steel flanges, spiral wound metallic gaskets & fasteners from designated location with in station premises / Centralized warehouse (as applicable) transporting the same to site, fabrication and erection of underground p iping including cutting, edge preparation, bending, threading, lining up and welding, excavating, trenching in all kind of soil to s pecific depths as indicated in drawings and installing pipes and all types of pipe fittings like flanges, elbows, equal and reducing outlet tees, concentric/eccentric reducers, drain funnels, vent pipe and tapping for instrument such as pressure gauges, thermal relief valves, thermowells etc., underground at elevations indicated in the drawing connecting with equipme nt nozzles, valves, vessels, in-line instruments etc., cleaning of coated pipes by water flushing after cleaning by compressed air h ydrostatic testing of each section to the specified pressure, draining the water, tie-in, back filling, restoration of site final cl eaning up and disposal of water and surpluses, providing all inputs such as labour, materials equipment and consumable necessary to perform the work (other than those specifically undertaken to be supplied by the owner under the contract) .The scope shall also include cleaning of internal surface of pipes conforming to SSPC SP-10 of Flanges, fiitings and at all location where coating has been destroyed due to welding and repairing the internal surface by application of 2-pack cold cured Isophthalic polyster acrylic co-polymer glass flake filled /Liquid epoxy / Equivalent with coating of thickness as per specifications. The locations where internal coating repair is expected would be at pipe end, Flanges, pipe fittings ,valve location so that the internal of pipe surface is not directly exposed to water and completing the work in all respects in accordance with the drawings, specifications and instructions of Site Engineer / EIC. Note:- 1) Charges for applying polyurethane coating(PU) for exposed steel surfaces of Bare Pipes, Pipe Joints, Fittings, Flanges, equipment and valves etc shall be paid under separate SOR Item. 2) Charges for supply of pipe with internal coating shall be paid under separate SOR items" Item 120.A.450
960 960 14" ODx 0.375" WT IS3589 FE410 Pipe U/G Item 120.A.460 10 M
961 961 12.75" ODx 0.250" WT IS3589 FE410 Pipe U/G Item 120.A.470 110 M
962 962 10.75" ODx 0.250" WT IS3589 FE410 Pipe U/G Item 120.A.480 60 M
963 963 8.625" ODx 0.250" WT IS3589 FE410 Pipe U/G Item 120.A.490 10 M
964 964 6.625" ODx 0.250" WT IS3589 FE410 Pipe U/G Item 120.A.500 10 M
965 965 4.5" ODx 0.237" WT ASTM A 106 Gr B Pipe FW U/G Item 120.A.510 13 M
966 966 3.5" OD x 0.216"WT ASTM A 106 Gr B FW U/G Item 120.A.520 8 M
967 967 2.375" OD x 0.218"WT ASTM A 106 Gr B FW U/G Item 120.A.530 4 M
968 968 1.315" ODx 0.179" WT ASTM A 106 Gr B Pipe FW U/G Item 120.A.540 2 M
969 969 "Above ground piping for Fuel line / Air line: Taking delivery of pipes, pipe fittings, steel flanges, spiral wound metallic gaskets & fasteners from designated location within s tation premises, transporting the same to site, fabrication and erection of above ground piping including cutting, edge preparation , bending, threading, lining up, welding and installing pipes and pipe fittings, flanges, elbows, equal and reducing outlet tees, c oncentric reducers, drain funnels, vent pipes and tapping for instruments such as pressure gauges, thermal relief valves, thermowell s etc., installing above ground at all elevations connecting with equipment nozzles, valves, vessels, in line instruments et c., welded and threaded pipe line of different pressure ratings, flushing pipes by water after cleaning by compressed air including air cleaning prior to installation of valve by card board/ Tin blasting method, hydrostatic testing of each section to the specified pressure, draining the water, tie-in, final cleaning-up and disposal of wastes and surpluses including providing all inputs such as labour, material, equipments and consumables necessary to perform the work (other than those specifically under taken by the owner in this contract).completing the work in all respects in accordance with the drawings, specifications and instructions of Site Engin eer / EIC. " Item 120.A.550
970 970 2.375" ODx 0.218" WT ASTM A 106 Gr B Pipe F/A Item 120.A.560 170 M
971 971 1.315" ODx 0.179" WT ASTM A 106 Gr B Pipe F/A Item 120.A.570 190 M
972 972 "Under ground piping for Fuel / Air piping: Taking delivery of pipes, pipe fittings, steel flanges, spiral wound metallic gaskets & fasteners from designated location within st ation premises transporting the same to site, fabrication and erection of underground piping including cutting, edge preparation, be nding, threading, lining up and welding, excavating, trenching in all kind of soil to specific depths as indicated in drawings and i nstalling pipes and all types of pipe fittings like flanges, elbows, equal and reducing outlet tees, concentric/eccentric reducers, drain funnels, vent pipe and tapping for instrument such as pessure gauges, thermal relief valves, thermowells etc., underground at elevations indicated in the drawing connecting with equipment nozzles, valves, vessels, in-line instruments etc., cleaning the mater ial surface by sandblast cleaning, coating and wrapping the pipes/pipe fittings with coaltar base tape coating material (including t he supply of coating tape, precoat material etc.), holiday detection of the coating, cleaning of coated pipes by water flushing afte r cleaning by compresed air prior to installation of valve, cleaning by card board/ Tin blasting method, hydrostatic testing of each section to the specified pressure, draining the water, tie-in, back filling, restoration of site final cleaning up and disposal of water and surpluses, providing all inputs such as labour, materials equipment and consumable necessary to perform the work (other th an those specifically undertaken to be supplied by the owner under the contract) and completing the work in all respects in accorda nce with the drawings, specifications and instructions of the Site Engineer / EIC." Item 120.A.580
973 973 2.375" ODx 0.237"WT ASTM A 106 Gr B F/A/ U/G Item 120.A.590 40 M
974 974 1.315" ODx 0.237"WT ASTM A 106 Gr B F/A/ U/G Item 120.A.600 50 M
975 975 "Valves: Taking delivery of valves of all types and pressure rating from the designated Centralized warehouse location within the st ate (Details of warehouse given in SCC), transporting the same to site, erecting above ground on preconstructed foundations or nder ground including earth work in excavation and filling for under ground valves at elevations specified in the drawings, priming and painting of above ground valves, PU Painting of under ground portions (if applicab le) including all inputs, labour, material and consumable (other than those specifically undertaken to be supplied by the owner) and completing the work in all respects in accordance with the drawings, manufacturer's installation instructions and specifications and instructions of the Site Engineer / EIC. " Item 120.A.610
976 976 12" x ANSI 600# MOV F/F API 6D Ball Valve Item 120.A.620 13 EA
977 977 8" x ANSI 600# MOV F/F API 6D Ball Valve Item 120.A.630 25 EA
978 978 14"x 600# MOV F/F A/G API 6D Ball Valve Item 120.A.640 16 EA
979 979 4" x ANSI 600# HOV F/F A/G API 6D Ball Valve Item 120.A.650 2 EA
980 980 6"x 600# MOV F/F A/G API 6D Ball Valve Item 120.A.660 10 EA
981 981 6" x ANSI 300# MOV F/F A/G API 6D Ball Valve Item 120.A.670 8 EA
982 982 8" x ANSI 300# MOV F/F API 6D Ball Valve Item 120.A.680 8 EA
983 983 8" x ANSI 300# ROV F/F API 6D Ball Valve Item 120.A.690 2 EA
984 984 6" x ANSI 300# ROV F/F API 6D Ball Valve Item 120.A.700 2 EA
985 985 "Valves: Taking delivery of valves of all types and pressure rating from the designated location within station premises / Centralized warehouse (as applicable), transporting the same to site, erecting above ground on preconstructed fou ndations or underground including earth work in excavation and filling for under ground valves at elevations specified in the drawin gs, priming and painting of above ground valves, PU Painting of under ground portions (if applicable) including all inputs, labour, material and consumable (other than those specifically undertaken to be supplied by the owner) and completing the work in all respec ts in accordance with the drawings, manufacturer's installation instructions and specifications and instructions of the Site Enginee r / EIC. " Item 120.A.710
986 986 2" x ANSI 600# HOV F/F API 6D Ball Valve Item 120.A.720 45 EA
987 987 2" x ANSI 300# HOV F/F API 6D Ball Valve Item 120.A.730 10 EA
988 988 1" x ANSI 800# HOV W/W BS 5351 BALL VALVE Item 120.A.740 101 EA
989 989 3"x 600# HOV F/F A/G API 6D Ball Valve Item 120.A.750 8 EA
990 990 3"x 300# HOV F/F A/G API 6D Ball Valve Item 120.A.760 4 EA
991 991 "Installation of Valves:( Process Piping): Taking delivery of valves of all types and pressure rating from the designated location within station premises / Centralized wareho use located within the state (Details of warehouse given in SCC), transporting the same to site, erecting above ground on preconstru cted foundations or underground including earth work in excavation and filling for under ground valves at elevations specified in th e drawings, priming and painting of above ground valves, PU Painting of under ground portions (if applicable) including all inputs, labour, material and consumable (other than those specifically undertaken to be supplied by the owner) and completing the work in al l respects in accordance with the drawings, manufacturer's installation instructions and specifications and instructions of the Site Engineer / EIC. - Swing Check Valves" Item 120.A.770
992 992 12"x ANSI 600# F/F API 6D Swing Check Valve -A/G Item 120.A.780 2 EA
993 993 8"x ANSI 600# F/F API 6D Swing Check Valve Item 120.A.790 4 EA
994 994 8"x ANSI 300# F/F API 6D Swing Check Valve Item 120.A.800 1 EA
995 995 14" x 600# API 6D SWING CHECK VALVE F/F, A/G Item 120.A.810 2 EA
996 996 "Valves: Taking delivery of valves of all types and pressure rating from the designated location within station premises / Centralized warehouse (as applicable), transporting the same to site, erecting above ground on preconstructed foundations or underground including earth work in excavation and filling for under ground valves at elevations specified in the drawings, priming and painting of above ground valves, PU Painting of under ground portions (if applicable) including all inputs, labour, material and consumable (other than those specifically undertaken to be supplied by the owner) and completing the work in all respects in accordance with the drawings, manufacturer's installation instructions and specifications and instructions of the Site Engineer / EIC. – For air line " Item 120.A.820
997 997 2"x ANSI 300 # HOV F/F API 600 Gate / BS 5351 Ball Valve (For Fuel / Air Piping) Item 120.A.830 11 EA
998 998 1"x ANSI 300 # HOV F/F API 600 Gate / BS 5351 Ball Valve (For Fuel / Air Piping) Item 120.A.840 16 EA
999 999 "Valves: Taking delivery of valves of all types and pressure rating from the designated location within station premises / Centralized warehouse (as applicable), transporting the same to site, erecting above ground on preconstructed fou ndations or underground including earth work in excavation and filling for under ground valves at elevations specified in the drawin gs, priming and painting of above ground valves, PU Painting of under ground portions (if applicable) including all inputs, labour, material and consumable (other than those specifically undertaken to be supplied by the owner) and completing the work in all respec ts in accordance with the drawings, manufacturer's installation instructions and specifications and instructions of the Site Enginee r / EIC.- Globe valve " Item 120.A.850
1000 1000 12" ANSI 600 # F/F BS-1873 GLOBE Valve Item 120.A.860 1 EA
1001 1001 8"x ANSI 600 # F/F BS-1873 GLOBE Valve Item 120.A.870 8 EA
1002 1002 6"x ANSI 600 # F/F BS-1873 GLOBE Valve Item 120.A.880 4 EA
1003 1003 4"x ANSI 600# F/F BS-1873/BS EN ISO 15761 GLOBE Valve Item 120.A.890 1 EA
1004 1004 2"x ANSI 600# F/F BS-1873 GLOBE Valve Item 120.A.900 18 EA
1005 1005 8"x ANSI 300# F/F BS-1873/BS EN ISO 15761 GLOBE Valve Item 120.A.910 1 EA
1006 1006 6"x ANSI 300# F/F BS-1873/BS EN ISO 15761 GLOBE Valve Item 120.A.920 1 EA
1007 1007 2"x ANSI 300# F/F BS-1873/BS EN ISO 15761 GLOBE Valve Item 120.A.930 3 EA
1008 1008 1"x ANSI 800# W/W BS-1873/BS EN ISO 15761 GLOBE Valve Item 120.A.940 72 EA
1009 1009 14" ANSI 600 # F/F BS-1873 GLOBE Valve Item 120.A.950 1 EA
1010 1010 3"x ANSI 600# F/F BS-1873/BS EN ISO 15761 GLOBE Valve Item 120.A.960 8 EA
1011 1011 3"x ANSI 300 # F/F BS-1873/BS EN ISO 15761 GLOBE Item 120.A.970 2 EA
1012 1012 "Valves: Taking delivery of valves of all types and pressure rating from the designated location within station premises / Centralized warehouse (as applicable), transporting the same to site, erecting above ground on preconstructed fou ndations or underground including earth work in excavation and filling for under ground valves at elevations specified in the drawin gs, priming and painting of above ground valves, PU Painting of under ground portions (if applicable) including all inputs, labour, material and consumable (other than those specifically undertaken to be supplied by the owner) and completing the work in all respec ts in accordance with the drawings, manufacturer's installation instructions and specifications and instructions of the Site Enginee r / EIC.- Thermal Relief Valves " Item 120.A.980
1013 1013 1" x 1" Thermal Relief Valve F/F ANSI 600# x 300 Item 120.A.990 49 EA
1014 1014 1" x 1" Thermal Relief Valve F/F ANSI 300# x 300 Item 120.A.1000 16 EA
1015 1015 "Installation of Valves(for Fire water Lines-Tanks & Piping) : Taking delivery of valves of all types and pressure rating from thedesignated location within station premises / Centralized warehouse (as applicable), transporting the same tosite, erecting above ground on preconstructed foundations or undergroundincluding earth work in excavation and filling for under ground valvesat elevations specified in the drawings, priming and painting of aboveground valves, flood coating and wrapping of under ground portions (ifapplicable) including all inputs, labour, material and consumable (otherthan those specifically undertaken to be supplied by the owner) andcompleting the work in all respects in accordance with the drawings,manufacturer's installation instructions and specifications andinstructions of the Site Engineer /EIC. Note:The cost of construction of Valve foundations shall be measured &paid separately under respective civil items. - Gate valves " Item 120.A.1010
1016 1016 14"x ANSI 150 # HOV F/F API 600 Gate Valve FW Item 120.A.1020 1 EA
1017 1017 12"x ANSI 150 # HOV F/F API 600 Gate Valve FW Item 120.A.1030 26 EA
1018 1018 10"x ANSI 150 # HOV F/F API 600 Gate Valve FW Item 120.A.1040 4 EA
1019 1019 8"x ANSI 150 # HOV F/F API 600 Gate Valve FW Item 120.A.1050 4 EA
1020 1020 6"x ANSI 150 # HOV F/F API 600 Gate Valve FW Item 120.A.1060 2 EA
1021 1021 4"x ANSI 150 # HOV F/F API 600 Gate Valve FW Item 120.A.1070 41 EA
1022 1022 3"x ANSI 150 # HOV F/F API 600 Gate Valve FW Item 120.A.1080 5 EA
1023 1023 2"x ANSI 150 # HOV F/F API 600 Gate Valve FW Item 120.A.1090 5 EA
1024 1024 1" x ANSI 800# HOV W/W API 602 Gate Valve Item 120.A.1100 20 EA
1025 1025 "Installation of Valves(for Fire water Lines-Tanks & Piping) : Taking delivery of valves of all types and pressure rating from thedesignated location within station premises / Centralized warehouse (as applicable), transporting the same tosite, erecting above ground on preconstructed foundations or undergroundincluding earth work in excavation and filling for under ground valvesat elevations specified in the drawings, priming and painting of aboveground valves, flood coating and wrapping of under ground portions (ifapplicable) including all inputs, labour, material and consumable (otherthan those specifically undertaken to be supplied by the owner) andcompleting the work in all respects in accordance with the drawings,manufacturer's installation instructions and specifications andinstructions of the Site Engineer /EIC. Note:The cost of construction of Valve foundations shall be measured &paid separately under respective civil items. - Swing Check Valves " Item 120.A.1110
1026 1026 8"x ANSI 150# F/F BS 1868 Swing/Dual plate Check Valve FW Item 120.A.1120 1 EA
1027 1027 4"x ANSI 150 # F/F BS 1868 Swing Check Valve FW Item 120.A.1130 1 EA
1028 1028 3"x ANSI 150 # F/F BS 1868 Swing Check Valve FW Item 120.A.1140 1 EA
1029 1029 2"x ANSI 150 # F/F BS 1868 Swing Check Valve Item 120.A.1150 1 EA
1030 1030 High Volume Long Range Foam Monitor 750 GPM capacity stand post type with inlet flange of 4" X 150# HVLR Item 120.A.1160 11 EA
1031 1031 Stand Post Type double way fire hydrant fitted with 2 Nos of single landing valve complete as per IS: 5290 alongwith 4" x 150# WNRF Flange Item 120.A.1170 36 EA
1032 1032 "Radiographic Inspection: Inspection of welding by radiographic method on all types of piping including processing of films and interpreting the results of we ld quality and reporting the same to the Site Engineer together with recommendations as to the acceptability or otherwise of the wel ds, submitting the finished radiographic films as may be approved or directed by Engineer-in-Charge inclusive of supply of all peson nel, labour, materials, equipment, consumable, inputs, etc. and providing all services complete in all respects as envisaged in the contract documents. Note: i) Payment will be on the basis of number of welds of the respective size radiographed and shall be all inclusive for the complete job of radiographic inspection as envisaged in the contract document. ii) Radiography not involving full girth weld will be paid at 50% of the rate for full girth weld for the respective size. iii) For set-on type branch welding, the rate for radiography will be as applicable to the branch pipe size. iv) Repeat radiography of individual welds due to defective films or repair of welds shall be done at contractor's cost. In case where radiography is not possible: v) Verification by utrasonic testing shall be done at contractors cost. vi) Magenetic particle inspection as and where required shall be done at Contractors cost. " Item 120.A.1180
1033 1033 16" NB Pipe Joints RT Item 120.A.1190 30 EA
1034 1034 14" NB Pipe Joints RT Item 120.A.1200 22 EA
1035 1035 8" NB Pipe Joints RT Item 120.A.1210 172 EA
1036 1036 6" NB Pipe Joints RT Item 120.A.1220 46 EA
1037 1037 4" NB Pipe Joints RT Item 120.A.1230 50 EA
1038 1038 3" NB Pipe Joints RT Item 120.A.1240 85 EA
1039 1039 2" NB Pipe Joints RT Item 120.A.1250 118 EA
1040 1040 1" NB Pipe Joints RT Item 120.A.1260 160 EA
1041 1041 12" NB Pipe Joints RT Item 120.A.1270 20 EA
1042 1042 10" NB Pipe Joints RT Item 120.A.1280 10 EA
1043 1043 "Fabrication of Mitre Bends - Long Radius: Taking delivery of pipes from designated locations, transporting the same to site and fabrication of carbon steel piping specials by cutting, edge preparation, welding, all types of testing including radiography & including supply of all inputs such as labour, mat erials (other than those specifically undertaken to be supplied by the Owner under the contract), equipments, consumables etc. neces sary to perform and completing the work in all respects in accordance with drawings, specifications and instructions of the Site Eng ineer / EIC " Item 120.A.1290
1044 1044 14" OD x 0.375" WT more than 45 ° & up to 90 ° Mitre Bend Item 120.A.1300 1 EA
1045 1045 12.75" OD x 0.375" WT more than 45° & up to 90° Mitre Bend Item 120.A.1310 9 EA
1046 1046 10.75" OD x 0.365"/0.250" more than 45 ° & up to 90 ° Mitre Bend Item 120.A.1320 2 EA
1047 1047 8.625" OD x 0.322"/0.250" more than 45 ° & up to 90 ° Mitre Bend Item 120.A.1330 2 EA
1048 1048 6.625" OD x 0.280"/0.250" more than 45 ° & up to 90 ° Mitre Bend Item 120.A.1340 2 EA
1049 1049 "Dismantling of Structures: Dismantling by opening joints or by gas cutting/ cold cutting (wherever required as per site condition) of existing steel structural such as support for pipes, pipe fittings, valves, plate forms, walkways, stairways etc. including excav ation work wherever required handling, loading into truck for purpose of weighing, shifting to the designated location within the station premises and handing over, completing the work in all respect as per drawings, instructio n of the Site Engineer / EIC. " Item 120.A.1350 3 TO
1050 1050 "Dismantling of Piping (Aboveground): Dismantling of existing over ground piping works of all types and sizes by opening flange joints or by gas cutting/ cold cutting or any other approved suitable means without damaging other portions of work. The job includes cutting the pipes to required sizes as directed, taking out valves, flanges, tees, bends, gaskets nuts, bolts etc. attached supports alongwith any instruments such as pressure gauge, temperature gauge etc. handling, transporting and storing at owner's designated store in safe manner to avoid damage including supply of all labour, materials, equipments, consumables etc. necessary to perform and complete the work in all respects as per drawings, instructions of the Site Engineer / EIC (payment shall be made on linear measurement of dismantled piping including bends tees etc.). Note : The contractor shall indicate the piping system to be dismantled and shall take specific approval from the Site engineer before dismantling of pipe. Certain redundant pipes which in the opinion of the Owner need not be retrieived, those items shall not be dismantelled. " Item 120.A.1360 1 TO
1051 1051 " Dismantling of Piping Underground: Dismantling the existing under ground piping, locating, retrieving including excavating the prope r trenches by cutting the pipes without damaging other portions of work. The job includes cutting the pipes to required sizes as di rected, taking out valves, flanges, tees, bends, gaskets, nuts, bolts etc., handling, transporting and storing at owner's designated store in safe manner to avoid damage including supply of all labour, materials, equipment consumables etc. necessary to perform and complete the work in all respects as per drawing, instructions of the Site Engineer / EIC. (Payment shall be made on the linear mea surement of dismantled piping including bend, tees, reducers etc.). Note : The contractor shall indicate the piping system to be dismantled and shall take specific approval from the Site engineer befo re dismantling of pipe. Certain redundant pipes which in the opinion of the Owner need not be retrieved, those items shall not be dismantled. " Item 120.A.1370 2 TO
1052 1052 "Development of As Built Drawings , Data Sheets etc: Development of as built drawings, data sheets, system details covering all addit ional facilities incorporated under this project in the station and furnishing them as reference document. Additionally, electronic copy of the documents shall also be furnished in compact disks- For all stations, T-Point, IPIG and SV stations" Item 120.A.1380 1 LS
1053 1053 "FW Network Analysis: Model Building and Flow Analysis by using Pipenet/Sprink/Flowmaster Software, suggesting the requirement of ori fice plate for flow and pressure control, preparation of reports, schematic drawings, recommendations and suggesting the pipe sizes in the fire water network so that the fire fighting system meets the requirement of OISD 117, latest Edition. Completing the work in all respect as per the defined scope of work and instructions of Site Engineer/EIC." Item 120.A.1390 4 LS
1054 1054 Flexibility and piping stress analysis as per specification Item 120.A.1400 2 LS
1055 1055 "Temporary Barricading: Providing Temporary Barricading made of GI/ steel sheet with angle iron frame (40x40x6) in panels of 1.5 to 2 .0m including lateral/ vertical angle bracing/ steel beam at bottom for stability, earth filling up to 300mm height above" Item 120.A.1410 2000 SQM
1056 1056 "Valves: Taking delivery of valves of all types and pressure rating from the designated Centralized warehouse location within the state (Details of warehouse given in SCC), transporting the same to site, erecting above ground on preconstructed foundations or underground including earth work in excavation and filling for under ground valves at elevations specified in the drawings, priming and painting of above ground valves, PU Painting of under ground portions (if applicable) including all inputs, labour, material and consumable (other than those specifically undertaken to be supplied by the owner) and completing the work in all respects in accordance with the drawings, manufacturer's installation instructions and specifications and instructions of the Site Engineer / EIC- Control Valves" Item 120.A.1420
1057 1057 14" 600# Control Valve F/F Item 120.A.1430 1 EA
1058 1058 6" 600# Control Valve F/F Item 120.A.1440 1 EA
1059 1059 6" 300# Control Valve F/F Item 120.A.1450 1 EA
1060 1060 12" 600# Control Valve F/F Item 120.A.1460 1 EA
1061 1061 8" 600# Control Valve F/F Item 120.A.1470 3 EA
1062 1062 8" 300# Control Valve F/F Item 120.A.1480 1 EA
1063 1063 20 COMPOSITE Item 120.B
1064 1064 Supply and Erection of Structural Steel: Supplying at site, steel structural items such as steel plates, bars, MS gratings, chequere d plates, angles, beams channels, commercial quality heavy pipes, C.I. Rollers, bolts & nuts, washers, grouting bolts, padding plate s etc., fabrication and erection of saddle supports and other type of supports for pipes manifolds and valves, fabrication and erect ion of platforms walkways, stairways etc., sand blast/ power brush cleaning, priming and painting the finished structures including supply of all other inputs such as labour, materials, consumable etc. necessary to perform and complete the work in all respect, in accordance with drawings, specifications and instructions of the Site Engineer / EIC. Item 120.B.10 21 TO
1065 1065 " Supply and Erection of Electroforged Grating: Supply and Erection of Electroforged Grating Supplying at site, steel structural ite ms such as steel plates, bars, fabrication of gratings by electroforged method, after complete fabrication entire gratings shall be Hot Dip galvanized, gratings shall be normally of size 810mm X 250mm for steps and 1200mm X 1000 mm or 810mm X 1000 mm for platforms / walkways, or any size as advised by EIC. Placing gratings in a replaceable manner bolting with base frame of ISA by suitable GI c lamps and GI fasteners, including supply of all other inputs such as labour, materials, consumable etc. necessary to perform and com plete the work in all respect, in accordance with drawings, specifications and instructions of the Site Engineer / EIC. " Item 120.B.20 4 TO
1066 1066 Painting: Cleaning exposed steel surfaces of piping, equipment and valves etc. by abrasive blasting or with power wire brush (wherev er abrasive blast cleaning is not possible) free of dust, grease, mill scales etc. priming with one coat of primer and painting the surfaces with two coats as per specification, with approved materials, paints, brushes, labour, equipment etc. and completing the jo b in all respects as per specification and instructions of the Site Engineer / EIC. All materials including supply of paint are in t he scope of contractor. Item 120.B.30
1067 1067 Zinc Ethyl Slicate Primer Item 120.B.40 2160 SQM
1068 1068 High Build EPOXY MIO Item 120.B.50 2160 SQM
1069 1069 Isocynate Aliphatic Poly Urethene(PU) Item 120.B.60 2160 SQM
1070 1070 "PU /liquid epoxy Coating of under ground piping: Cleaning exposed steel surfaces of piping, equipment and valves etc. by sand blasting or with power wire brush (wherever sand blast cleaning is not possible) free of dust, grease, mill scales etc. and applying single layer polyurethane coating(PU) using 100% Solvent free elastomeric polyurethane/ liquid epoxy, with approved materials, labour, equipment etc. and completing the job in all respects as per specification and instructions of the Site Engineer / EIC." Item 120.B.70 450 M2
1071 1071 "Copper Strips/ Flats for Jumpers for Flanged Joints of the Product Process Piping: Supply and Installation of one copper jumper per flanged joint across the flanged joints for valves, spool piece, branch offs etc., of product process piping, The job includes cutt ing drilling of holes of required size in the copper strips/ flats for bolting purpose and complete the works in all respects as per specifications & drawings and instructions of Site Engineer/ EIC. Note: Copper jumpers shall be installed in all the flanged joints of Product Process piping only and not in fire water lines. " Item 120.B.80
1072 1072 Up to 30 mm wide x 3 mm thick Copper strip Item 120.B.90 135 EA
1073 1073 30 - 50 mm wide x 3 mm thick Copper strip Item 120.B.100 135 EA
1074 1074 "HOT/EOT CRANE: 5 Ton cap HOT crane Fire Fighting Pump Shed_Design, manufacture, inspection & testing at manufacturer's works and s upply of HOT/ EOT cranes (having main girder beam with box type construction) as per specifications, taking delivery, shifting / tra nsporting within the pump station premises and erecting on the shed Girder, assemblies / sub-assemblies, auxiliaries, girders etc, aligning checking for free movement of the crane from one end to other and cross movement, cleaning by sand blasting, priming, painting as per painting schedule testing of the crane with specified load in presence of the m anufacturer's representative including providing all labour, materials, equipments and consumables necessary to perform and complete the works in all respects as per specifications, drawings and instructions of Site Engineer / EIC. " Item 120.B.110 1 EA
1075 1075 "Medium Velocity Water Sprinkler System (Automatic) : Design, Detailed Engineering, supply, fabrication, erection/Installation and commissioning of complete medium velocity water sprinkler systems for, barrel area, filtratio n, metering and piping area at each location as per the details mentioned below: Medium Velocity Water Sprinkler System: Automatic Medium velocity water Sprinkler System for, barrel area, filtration, metering and Piping Area: Design, detail engineering, drawing and development of scheme for automatic medium velocity water sprinkler system for the equipment and piping area including supply of all material like Deluge valve(Wet Type/ Dry Type), Spray nozzles, pressure switch , pressure gauge, piping, valves, flanges, coupling, pipe fittings, brackets, clamps, fasteners, solenoid switches, S.S piping, stra iners, along with all accessories as per the approved scheme at site , erection and installation of piping, cabling, equipments and instruments control panel etc, provision of compressed air/pneumatic piping from owner's compressed air header located near compress or room for Dry Type Deluge Valve including dismantling, breaking of road etc. as required for setting out of the system and making good the same, hooking up the system with the hydrant network, sand blast cleaning, priming and painting (Zinc Ethyl Silicate Primer, Hig h Build EPOXY MIO, Isocynate Aliphatic PolyUrethane(PU) in sign al red colour); internal coating with liquid epoxy, Carrying out all electrical and instrumentation works to enable auto actuation of the deluge valve and medium velocity water sprinkler system based on alarm signal from QB sensors/ gas detectors/ flame detectors. Carrying out the electronic integration of the system with the control panel and providing alarm and automatic actuation of the deluge valves with manual over-ride provision, testing & commissioning of the system including cost of all labour, services, materials tools & tackles consumables, first operation & furnishing of operation and maintenance manuals on lump sum basis as per sp ecifications, International standard procedures, approved scheme, drawings and the direction of Site Engineer /EIC. Note:1. The control panel and control console with PC will be installed under the work of Gas detection system and the MV system is to be integrated with the existing system. 2. For System Designing/Area Calculation & inter distances between block facilities refer the General layout plan and Assembly Piping Area of respective Station " Item 120.B.120 2 LS
1076 1076 "Medium Velocity Water Sprinkler System (Manual): Design, Detailed Engineering, supply, fabrication, erection/Installation and commi ssioning of complete medium velocity water sprinkler systems for, barrel area and piping area at each location as per the details me n tioned below: Medium Velocity Water Sprinkler System: Manual Medium velocity water Sprinkler System for, barrel area and Piping Area: Design, detail engineering, drawing and development of scheme for manual medium velocity water sprinkler system for the barrels (Scraper Launching Barrel and Scraper receiv ing Barrel) and piping area including supply of all material like Deluge valve(Wet Type), Spray nozzles, pressure switch, pressure gauge, piping, valves, flanges, coupling, pipe fi ttings, brackets, clamps, fasteners, solenoid switches, S.S piping, strainers, along with all accessories as per the approved scheme at site, erection and installation of piping, equipments et c, including dismantling, breaking of road etc. as required for setting out of the system and making good the same, hooking up the s ystem with the hydrant network, sand blast cleaning, priming and painting (Zinc Ethyl Silicate Primer, High Build EPOXY MIO, Isocyna te Aliphatic Poly Urethane(PU) in signal red colour); internal coating with liquid epoxy. Testing & commissioning of the system including cost of all labour, services, materials tools & tackles consumables, first operation & furnishing of operation and maintenance manuals on lump sum basis as per specifications, International standard procedures, approved scheme, drawings and the direction of Site Engineer /EIC. Note: For System Designing/Area Calculation & inter distances between block facilities refer the General layout plan and Assembly Pi ping Area of respective Station " Item 120.B.130 1 EA
1077 1077 "WATER STORAGE TANKS (CONE ROOF VERTICAL TYPE): 18 m dia x 14.5 m height cone roof tank, 3400 KL CAPACITY)_Design, preparation of de tailed fabrication & construction drawings and detailing along with supporting calculation meeting with the requirement in accordanc e with tender specification/ stipulations/ drawings, taking delivery and Transportation of all owner supplied materials as listed in SCC from owner's storage location within the owner designated premises, supply of all other materials required to meet the requirement stipulated in tender and approv ed detailed fabrication & construction drawings , rolling, fabrication, erection and welding of all steel plates for specified capac ity fixed roof type fire water storage tanks comprising of bottom, shell, cone roof including roof structure , wind girders, spiral stairway, hand rails, curb angle, and providing all manholes, nozzles etc. fittings and fixing of all appurtenances, instruments, ac cessories, sealing devices, safety devices etc. , suitable platform for the maintenance of level switches, providing support bracket s for cable trays, piping etc, conducting hydrostatic test and all other necessary tests, cal ibration of storage tanks including st rapping with tapes, providing scaffolding for calibration, calibration chart etc. Painting of bottom side of the bottom plates with specified paints, internal and external painting of the tank with specified paint system, Visual and Radiographic inspection of Weld as per provisions of API 650/IS 803 latest edition and in line with the specifications in the tender document complete in all respe cts inclusive of all materials, tools and tackles etc., as per specifications and instructions of the Engineer in Charge. " Item 120.B.140 1 EA
1078 1078 30 SUPPLY Item 120.C
1079 1079 Supply and delivery of Spiral Wound Metallic Gaskets at respective stations as per Station wise Break up of material supply and as p er technical specifications from approved vendors specified in tender document Item 120.C.10
1080 1080 14" SWMG ANSI 150# Item 120.C.20 10 EA
1081 1081 12" SWMG ANSI 150# Item 120.C.30 130 EA
1082 1082 10" SWMG ANSI 150# Item 120.C.40 18 EA
1083 1083 8" SWMG ANSI 150# Item 120.C.50 18 EA
1084 1084 6" SWMG ANSI 150# Item 120.C.60 16 EA
1085 1085 4" SWMG ANSI 150# Item 120.C.70 102 EA
1086 1086 3" SWMG ANSI 150# Item 120.C.80 18 EA
1087 1087 2" SWMG ANSI 150# Item 120.C.90 18 EA
1088 1088 1 1/2" SWMG ANSI 150# Item 120.C.100 10 EA
1089 1089 1" SWMG ANSI 150# Item 120.C.110 10 EA
1090 1090 8" SWMG ANSI 300# Item 120.C.120 28 EA
1091 1091 6" SWMG ANSI 300# Item 120.C.130 37 EA
1092 1092 4" SWMG ANSI 300# Item 120.C.140 15 EA
1093 1093 3" SWMG ANSI 300# Item 120.C.150 34 EA
1094 1094 2" SWMG ANSI 300# Item 120.C.160 36 EA
1095 1095 1" SWMG ANSI 300# Item 120.C.170 105 EA
1096 1096 16" SWMG ANSI 600# Item 120.C.180 2 EA
1097 1097 14" SWMG ANSI 600# Item 120.C.190 43 EA
1098 1098 12" SWMG ANSI 600# Item 120.C.200 40 EA
1099 1099 8" SWMG ANSI 600# Item 120.C.210 86 EA
1100 1100 6" SWMG ANSI 600# Item 120.C.220 38 EA
1101 1101 4" SWMG ANSI 600# Item 120.C.230 8 EA
1102 1102 3" SWMG ANSI 600# Item 120.C.240 37 EA
1103 1103 2" SWMG ANSI 600# Item 120.C.250 158 EA
1104 1104 1" SWMG ANSI 600# Item 120.C.260 50 EA
1105 1105 Supply and delivery of Steel Fasteners at respective stations as per Station wise Break up of material supply and as per technical s pecifications from approved vendors specified in tender document. Item 120.C.270
1106 1106 Fasteners for Flanges 14" x 150# (1.000" Dia. X 6.00" Length ) Item 120.C.280 60 EA
1107 1107 Fasteners for Flanges 12" x 150# (0.875" Dia. X 5.50" Length ) Item 120.C.290 1392 EA
1108 1108 Fasteners for Flanges 10" x 150# (0.875" Dia. X 5.25" Length ) Item 120.C.300 180 EA
1109 1109 Fasteners for Flanges 8" x 150# (0.750" Dia. X 4.75" Length) Item 120.C.310 120 EA
1110 1110 Fasteners for Flanges 6" x 150# (0.750" Dia. X 4.50" Length) Item 120.C.320 80 EA
1111 1111 Fasteners for Flanges 4" x 150# (0.625" Dia. X 4.00" Length ) Item 120.C.330 868 EA
1112 1112 Fasteners for Flanges 3" x 150# (0.625" Dia. X 4.00" Length ) Item 120.C.340 60 EA
1113 1113 Fasteners for Flanges 2" x 150# (0.625" Dia. X 3.75" Length ) Item 120.C.350 40 EA
1114 1114 Fasteners for Flanges 1 1/2" x 150# (0.500" Dia. X 3.25" Length) Item 120.C.360 20 EA
1115 1115 Fasteners for Flanges 1" x 150# (0.500" Dia. X 3.00" Length ) Item 120.C.370 20 EA
1116 1116 Fasteners for Flanges 8" x 300# (0.875" Dia. X 6.25" Length) Item 120.C.380 270 EA
1117 1117 Fasteners for Flanges 8" x 300# (0.875" Dia. X 7.5" Length) - extended stud length for flanges with spectacle blind Item 120.C.390 64 EA
1118 1118 Fasteners for Flanges 6" x 300# (0.750" Dia. X 5.25" Length) Item 120.C.400 360 EA
1119 1119 Fasteners for Flanges 6" x 300# (0.750" Dia. X 6.25" Length) - extended stud length for flanges with spectacle blind Item 120.C.410 84 EA
1120 1120 Fasteners for Flanges 4" x 300# (0.75" Dia. X 5.00" Length ) Item 120.C.420 88 EA
1121 1121 Fasteners for Flanges 4" x 300# (0.75" Dia. X 5.75" Length ) - extended stud length for flanges with spectacle blind Item 120.C.430 8 EA
1122 1122 Fasteners for Flanges 3" x 300# (0.75" Dia. X 4.75" Length ) Item 120.C.440 104 EA
1123 1123 Fasteners for Flanges 3" x 300# (0.75" Dia. X 5.5" Length) - extended stud length for flanges with spectacle blind Item 120.C.450 10 EA
1124 1124 Fasteners for Flanges 2" x 300# /1" x 300# extended stud length for flanges with spectacle blind (0.625" Dia. X 4" Length ) Item 120.C.460 128 EA
1125 1125 Fasteners for Flanges 2" x 300# (0.625" Dia. X 4.75" Length ) - extended stud length for flanges with spectacle blind Item 120.C.470 84 EA
1126 1126 Fasteners for Flanges 1" x 300# (0.625" Dia. X 3.50" Length ) Item 120.C.480 136 EA
1127 1127 Fasteners for Flanges 14" x 600# (1.375" Dia. X 10.25" Length ) Item 120.C.490 580 EA
1128 1128 Fasteners for Flanges 14" x 600# (1.375" Dia. X 12.75" Length ) - extended stud length for flanges with spectacle blind Item 120.C.500 120 EA
1129 1129 Fasteners for Flanges 12" x 600# ( 1.25" Dia. X 12" Length ) - extended stud length for flanges with spectacle blind Item 120.C.510 192 EA
1130 1130 Fasteners for Flanges 12" x 600# (1.250" Dia. X 9.75" Length ) Item 120.C.520 720 EA
1131 1131 Fasteners for Flanges 8" x 600# (1.125" Dia. X 10" Length) - extended stud length for flanges with spectacle blind Item 120.C.530 202 EA
1132 1132 Fasteners for Flanges 8" x 600# (1.125" Dia. X 8.25" Length ) Item 120.C.540 1089 EA
1133 1133 Fasteners for Flanges 6" x 600# (1.0" Dia. X 9.0" Length) - extended stud length for flanges with spectacle blind Item 120.C.550 97 EA
1134 1134 Fasteners for Flanges 6" x 600# (1.000" Dia. X 7.50" Length ) Item 120.C.560 342 EA
1135 1135 Fasteners for Flanges 4" x 600# ( 0.875" Dia. X 7.75" Length ) - extended stud length for flanges with spectacle blind Item 120.C.570 26 EA
1136 1136 Fasteners for Flanges 4" x 600# (0.875" Dia. X 6.50" Length ) Item 120.C.580 78 EA
1137 1137 Fasteners for Flanges 3" x 600# ( 0.75" Dia. X 6.75" Length ) - extended stud length for flanges with spectacle blind Item 120.C.590 79 EA
1138 1138 Fasteners for Flanges 3" x 600# (0.750" Dia. X 5.50" Length) Item 120.C.600 182 EA
1139 1139 Fasteners for Flanges 2" x 600# ( 0.625" Dia. X 5.75" Length ) - extended stud length for flanges with spectacle blind Item 120.C.610 184 EA
1140 1140 Fasteners for Flanges 2" x 600# (0.625" Dia. X 4.75" Length ) Item 120.C.620 910 EA
1141 1141 Fasteners for Flanges 1" x 600# (0.625" Dia. X 5.0" Length ) - extended stud length for flanges with spectacle blind Item 120.C.630 10 EA
1142 1142 Fasteners for Flanges 1" x 600# (0.625" Dia. X 4.00" Length ) Item 120.C.640 216 EA
1143 1143 Supply and delivery of Steel Flanges at respective stations as per Station wise Break up of material supply and as per technical spe cifications from approved vendors specified in tender document: Item 120.C.650
1144 1144 8", WNRF FLANGE, ANSI - 300# (B 16.5)-ASTM A105 Item 120.C.660 26 EA
1145 1145 6", WNRF FLANGE, ANSI - 300# (B 16.5)-ASTM A350 LF2 Item 120.C.670 32 EA
1146 1146 4", WNRF FLANGE, ANSI - 300# (B 16.5)-ASTM A350 LF2 Item 120.C.680 13 EA
1147 1147 3", WNRF FLANGE, ANSI - 300# (B 16.5)-ASTM A350 LF2 Item 120.C.690 22 EA
1148 1148 2", WNRF FLANGE, ANSI - 300# (B 16.5)-ASTM A350 LF2 Item 120.C.700 34 EA
1149 1149 1", WNRF FLANGE, ANSI - 300# (B 16.5)-ASTM A350 LF2 Item 120.C.710 91 EA
1150 1150 16", WNRF FLANGE, ANSI - 600# (B 16.5) Item 120.C.720 12 EA
1151 1151 14", WNRF FLANGE, ANSI - 600# (B 16.5) Item 120.C.730 42 EA
1152 1152 12", WNRF FLANGE, ANSI - 600# (B 16.5) Item 120.C.740 40 EA
1153 1153 8", WNRF FLANGE, ANSI - 600# (B 16.5) Item 120.C.750 82 EA
1154 1154 6", WNRF FLANGE, ANSI - 600# (B 16.5) Item 120.C.760 32 EA
1155 1155 4", WNRF FLANGE, ANSI - 600# (B 16.5) Item 120.C.770 27 EA
1156 1156 3", WNRF FLANGE, ANSI - 600# (B 16.5) Item 120.C.780 19 EA
1157 1157 2", WNRF FLANGE, ANSI - 600# (B 16.5) Item 120.C.790 124 EA
1158 1158 1", WNRF FLANGE, ANSI - 600# (B 16.5) Item 120.C.800 54 EA
1159 1159 14", BLRF FLANGE, ANSI - 150# (B 16.5) Item 120.C.810 2 EA
1160 1160 12", BLRF FLANGE, ANSI - 150# (B 16.5) Item 120.C.820 8 EA
1161 1161 10", BLRF FLANGE, ANSI - 150# (B 16.5) Item 120.C.830 2 EA
1162 1162 8", BLRF FLANGE, ANSI - 150# (B 16.5) Item 120.C.840 2 EA
1163 1163 6", BLRF FLANGE, ANSI - 150# (B 16.5) Item 120.C.850 2 EA
1164 1164 4", BLRF FLANGE, ANSI - 150# (B 16.5) Item 120.C.860 10 EA
1165 1165 3", BLRF FLANGE, ANSI - 150# (B 16.5) Item 120.C.870 4 EA
1166 1166 2", BLRF FLANGE, ANSI - 150# (B 16.5) Item 120.C.880 4 EA
1167 1167 1", BLRF FLANGE, ANSI - 150# (B 16.5) Item 120.C.890 5 EA
1168 1168 8", BLRF FLANGE, ANSI - 300# (B 16.5)-ASTM A105 Item 120.C.900 6 EA
1169 1169 6", BLRF FLANGE, ANSI - 300# (B 16.5)-ASTM A350 LF2 Item 120.C.910 3 EA
1170 1170 4", BLRF FLANGE, ANSI - 300# (B 16.5)-ASTM A350 LF2 Item 120.C.920 5 EA
1171 1171 3", BLRF FLANGE, ANSI - 300# (B 16.5)-ASTM A350 LF2 Item 120.C.930 13 EA
1172 1172 2", BLRF FLANGE, ANSI - 300# (B 16.5)-ASTM A350 LF2 Item 120.C.940 14 EA
1173 1173 1", BLRF FLANGE,ANSI - 300# (B 16.5)-ASTM A350 LF2 Item 120.C.950 10 EA
1174 1174 16", BLRF FLANGE, ANSI - 600# (B 16.5) Item 120.C.960 4 EA
1175 1175 14", BLRF FLANGE, ANSI - 600# (B 16.5) Item 120.C.970 6 EA
1176 1176 12", BLRF FLANGE, ANSI - 600# (B 16.5) Item 120.C.980 6 EA
1177 1177 8", BLRF FLANGE, ANSI - 600# (B 16.5) Item 120.C.990 7 EA
1178 1178 6", BLRF FLANGE, ANSI - 600# (B 16.5) Item 120.C.1000 2 EA
1179 1179 4", BLRF FLANGE, ANSI - 600# (B 16.5) Item 120.C.1010 1 EA
1180 1180 3", BLRF FLANGE, ANSI - 600# (B 16.5) Item 120.C.1020 4 EA
1181 1181 2", BLRF FLANGE, ANSI - 600# (B 16.5) Item 120.C.1030 18 EA
1182 1182 1", BLRF FLANGE, ANSI - 600# (B 16.5) Item 120.C.1040 16 EA
1183 1183 14", SORF FLANGE, ANSI - 150# (B 16.5) Item 120.C.1050 8 EA
1184 1184 12", SORF FLANGE, ANSI - 150# (B 16.5) Item 120.C.1060 150 EA
1185 1185 10", SORF FLANGE, ANSI - 150# (B 16.5) Item 120.C.1070 24 EA
1186 1186 8", SORF FLANGE, ANSI - 150# (B 16.5) Item 120.C.1080 24 EA
1187 1187 6", SORF FLANGE, ANSI - 150# (B 16.5) Item 120.C.1090 18 EA
1188 1188 4", SORF FLANGE, ANSI - 150# (B 16.5) Item 120.C.1100 118 EA
1189 1189 3", SORF FLANGE, ANSI - 150# (B 16.5) Item 120.C.1110 24 EA
1190 1190 2", SORF FLANGE, ANSI - 150# (B 16.5) Item 120.C.1120 18 EA
1191 1191 1", SORF FLANGE, ANSI - 150# (B 16.5) Item 120.C.1130 10 EA
1192 1192 Supply and delivery of following mentioned Spectacle Blinds at respective stations as per Station wise Break up of material supply a nd as per technical specifications indicated in tender documents (As per ASME B16.48) Item 120.C.1140
1193 1193 8" Spectacle Blind 300# F/F A/G - ASTM A105 Item 120.C.1150 5 EA
1194 1194 6" Spectacle Blind 300# F/F A/G - ASTM A350 LF2 Item 120.C.1160 4 EA
1195 1195 4" Spectacle Blind 300# F/F A/G - ASTM A350 LF2 Item 120.C.1170 1 EA
1196 1196 3" Spectacle Blind 300# F/F A/G - ASTM A350 LF2 Item 120.C.1180 2 EA
1197 1197 2" Spectacle Blind 300# F/F A/G - ASTM A350 LF2 Item 120.C.1190 5 EA
1198 1198 1" Spectacle Blind 300# F/F A/G - ASTM A350 LF2 Item 120.C.1200 2 EA
1199 1199 14" Spectacle Blind 600# F/F A/G - ASTM A105 Item 120.C.1210 6 EA
1200 1200 12" Spectacle Blind 600# F/F A/G - ASTM A105 Item 120.C.1220 8 EA
1201 1201 8" Spectacle Blind 600# F/F A/G - ASTM A105 Item 120.C.1230 11 EA
1202 1202 6" Spectacle Blind 600# F/F A/G - ASTM A350 LF2 Item 120.C.1240 7 EA
1203 1203 4" Spectacle Blind 600# F/F A/G - ASTM A350 LF2 Item 120.C.1250 1 EA
1204 1204 2" Spectacle Blind 600# F/F A/G - ASTM A350 LF2 Item 120.C.1260 13 EA
1205 1205 1" Spectacle Blind 600# F/F A/G - ASTM A350 LF2 Item 120.C.1270 3 EA
1206 1206 3" Spectacle Blind 600# F/F A/G - ASTM A105 Item 120.C.1280 9 EA
1207 1207 Supply and delivery of pipe fittings at respective stations as per Station wise Break up of material supply and as per technical sp ecifications from approved vendors specified in tender document Item 120.C.1290
1208 1208 14"x12" 150# Un Equal Tee Item 120.C.1300 5 EA
1209 1209 14"x 10" ANSI 150# UnEqual Tee Item 120.C.1310 5 EA
1210 1210 14"x8" 150# Un Equal Tee Tee Item 120.C.1320 2 EA
1211 1211 14"x 6" ANSI 150# UnEqual Tee Item 120.C.1330 2 EA
1212 1212 12" x 10" ANSI 150# Un Equal Tee Item 120.C.1340 2 EA
1213 1213 12" x 8" ANSI 150# Un Equal Tee Item 120.C.1350 5 EA
1214 1214 12" x 6" ANSI 150# Un Equal Tee Item 120.C.1360 2 EA
1215 1215 12" x 4" ANSI 150# Un Equal Tee Item 120.C.1370 52 EA
1216 1216 10" x 8" ANSI 150# Un Equal Tee Item 120.C.1380 2 EA
1217 1217 10" x 6" ANSI 150# Un Equal Tee Item 120.C.1390 2 EA
1218 1218 10" x 4" ANSI 150# Un Equal Tee Item 120.C.1400 2 EA
1219 1219 8" x 6" ANSI 150# Un Equal Tee Item 120.C.1410 2 EA
1220 1220 8" x 4" ANSI 150# Un Equal Tee Item 120.C.1420 2 EA
1221 1221 8" x 3" ANSI 150# Un Equal Tee Item 120.C.1430 2 EA
1222 1222 6" x 4" ANSI 150# Un Equal Tee Item 120.C.1440 2 EA
1223 1223 6" x 3" ANSI 150# Un Equal Tee Item 120.C.1450 2 EA
1224 1224 4" x 3" ANSI 150# Un Equal Tee Item 120.C.1460 2 EA
1225 1225 4" x2" ANSI 150# Un Equal Tee Item 120.C.1470 2 EA
1226 1226 4" x 1" ANSI 150# Un Equal Tee Item 120.C.1480 2 EA
1227 1227 3" x 2" ANSI 150# Un Equal Tee Item 120.C.1490 2 EA
1228 1228 3" x 1" ANSI 150# Un Equal Tee Item 120.C.1500 2 EA
1229 1229 2" x 1" ANSI 150# Un Equal Tee Item 120.C.1510 2 EA
1230 1230 4"x2" 300# Unequal Tee -ASTM A420 Gr.WPL6 Item 120.C.1520 5 EA
1231 1231 2"x1" 300# Unequal Tee -ASTM A420 Gr.WPL6 Item 120.C.1530 22 EA
1232 1232 3"x2" 300# Unequal Tee -ASTM A420 Gr.WPL6 Item 120.C.1540 14 EA
1233 1233 3"x1" 300# Unequal Tee -ASTM A420 Gr.WPL6 Item 120.C.1550 75 EA
1234 1234 4"x3" 300# Unequal Tee -ASTM A420 Gr.WPL6 Item 120.C.1560 3 EA
1235 1235 14" x 8" ANSI 600# Unequal Tee Item 120.C.1570 5 EA
1236 1236 12"x 8" 600# Unequal Tee Item 120.C.1580 3 EA
1237 1237 12"x 6" 600# Unequal Tee Item 120.C.1590 1 EA
1238 1238 8"x6" 600# Unequal Tee Item 120.C.1600 1 EA
1239 1239 8"x4" 600# Unequal Tee Item 120.C.1610 1 EA
1240 1240 6"x4" 600# Unequal Tee Item 120.C.1620 1 EA
1241 1241 4"x2" 600# Unequal Tee Item 120.C.1630 3 EA
1242 1242 3"x1" 600# Un Equal Tee Item 120.C.1640 13 EA
1243 1243 2"x1" 600# Un Equal Tee Item 120.C.1650 11 EA
1244 1244 16"x14” x 600# Unequal tee Item 120.C.1660 2 EA
1245 1245 14" ANSI 150# Equal Tee Item 120.C.1670 4 EA
1246 1246 12" ANSI 150# Equal Tee Item 120.C.1680 14 EA
1247 1247 10" ANSI 150# Equal Tee Item 120.C.1690 4 EA
1248 1248 8" ANSI 150# Equal Tee Item 120.C.1700 4 EA
1249 1249 6" ANSI 150# Equal Tee Item 120.C.1710 4 EA
1250 1250 4" ANSI 150# Equal Tee Item 120.C.1720 14 EA
1251 1251 3" ANSI 150# Equal Tee Item 120.C.1730 4 EA
1252 1252 2" ANSI 150# Equal Tee Item 120.C.1740 4 EA
1253 1253 1" ANSI 150# Equal Tee Item 120.C.1750 5 EA
1254 1254 8" 300# Equal Tee -ASTM A 234 WPB Item 120.C.1760 8 EA
1255 1255 6" 300# Equal Tee - ASTM A420 Gr.WPL6 Item 120.C.1770 6 EA
1256 1256 3" 300# Equal Tee - ASTM A420 Gr.WPL6 Item 120.C.1780 14 EA
1257 1257 2" 300# Equal Tee - ASTM A420 Gr.WPL6 Item 120.C.1790 12 EA
1258 1258 1" 300# Equal Tee - ASTM A420 Gr.WPL6 Item 120.C.1800 12 EA
1259 1259 16" x 600# Equal Tee Item 120.C.1810 2 EA
1260 1260 14" x 600# Equal Tee Item 120.C.1820 6 EA
1261 1261 12" x 600# Equal Tee Item 120.C.1830 8 EA
1262 1262 8" 600# Equal Tee - WPHY 52 Item 120.C.1840 14 EA
1263 1263 4" 600# Equal Tee Item 120.C.1850 3 EA
1264 1264 3" ANSI 600# Equal Tee Item 120.C.1860 6 EA
1265 1265 2" ANSI 600# Equal Tee Item 120.C.1870 8 EA
1266 1266 1" ANSI 600# Equal Tee Item 120.C.1880 14 EA
1267 1267 14" ANSI 150# 90 deg LR Bends Item 120.C.1890 4 EA
1268 1268 12" ANSI 150# 90 deg LR Bends Item 120.C.1900 32 EA
1269 1269 10" ANSI 150# 90 deg LR Bends Item 120.C.1910 4 EA
1270 1270 8" ANSI 150# 90 deg LR Bends Item 120.C.1920 4 EA
1271 1271 6" ANSI 150# 90 deg LR Bends Item 120.C.1930 4 EA
1272 1272 4" ANSI 150# 90 deg LR Bends Item 120.C.1940 32 EA
1273 1273 3" ANSI 150# 90 deg LR Bends Item 120.C.1950 5 EA
1274 1274 2" ANSI 150# 90 deg LR Bends Item 120.C.1960 5 EA
1275 1275 1" ANSI 150# 90 deg LR Bends Item 120.C.1970 5 EA
1276 1276 8" ANSI 300# 90 deg LR Bends -ASTM A 234 WPB Item 120.C.1980 10 EA
1277 1277 6" ANSI 300# 90 deg LR Bends -ASTM A420 Gr.WPL6 Item 120.C.1990 10 EA
1278 1278 4" ANSI 300# 90 deg LR Bends -ASTM A420 Gr.WPL6 Item 120.C.2000 3 EA
1279 1279 3" ANSI 300# 90 deg LR Bends -ASTM A420 Gr.WPL6 Item 120.C.2010 30 EA
1280 1280 2" ANSI 300# 90 deg LR Bends -ASTM A420 Gr.WPL6 Item 120.C.2020 26 EA
1281 1281 1" ANSI 300# 90 deg LR Bends -ASTM A420 Gr.WPL6 Item 120.C.2030 96 EA
1282 1282 14" ANSI 600# 90 deg LR Bends Item 120.C.2040 15 EA
1283 1283 12" ANSI 600# 90 deg LR Bends Item 120.C.2050 12 EA
1284 1284 8" ANSI 600# 90 deg LR Bends Item 120.C.2060 26 EA
1285 1285 6" ANSI 600# 90 deg LR Bends Item 120.C.2070 16 EA
1286 1286 4" ANSI 600# 90 deg LR Bends Item 120.C.2080 15 EA
1287 1287 3" ANSI 600# 90 deg LR Bends Item 120.C.2090 8 EA
1288 1288 2" ANSI 600# 90 deg LR Bends Item 120.C.2100 36 EA
1289 1289 1" ANSI 600# 90 deg LR Bends Item 120.C.2110 48 EA
1290 1290 14" ANSI 150# 45 deg LR Bends Item 120.C.2120 4 EA
1291 1291 12" ANSI 150# 45 deg LR Bends Item 120.C.2130 24 EA
1292 1292 10" ANSI 150# 45 deg LR Bends Item 120.C.2140 4 EA
1293 1293 8" ANSI 150# 45 deg LR Bends Item 120.C.2150 4 EA
1294 1294 6" ANSI 150# 45 deg LR Bends Item 120.C.2160 4 EA
1295 1295 4" ANSI 150# 45 deg LR Bends Item 120.C.2170 18 EA
1296 1296 3" ANSI 150# 45 deg LR Bends Item 120.C.2180 4 EA
1297 1297 8" x 300# 45 deg LR Bends -ASTM A 234 WPB Item 120.C.2190 4 EA
1298 1298 6" x 300# 45 deg LR Bends -ASTM A420 Gr.WPL6 Item 120.C.2200 6 EA
1299 1299 16" x 600# 45 deg LR Bends WPHY 60/70 Item 120.C.2210 4 EA
1300 1300 14" ANSI 600# 45 deg LR Bends Item 120.C.2220 2 EA
1301 1301 12" ANSI 600# 45 deg LR Bends Item 120.C.2230 2 EA
1302 1302 8" ANSI 600# 45 deg LR Bends Item 120.C.2240 8 EA
1303 1303 6" ANSI 600# 45 deg LR Bends Item 120.C.2250 8 EA
1304 1304 4" ANSI 600# 45 deg LR Bends Item 120.C.2260 14 EA
1305 1305 10"x8" x Eccentric Reducer x 150# Item 120.C.2270 2 EA
1306 1306 10"x6" x Eccentric Reducer x 150# Item 120.C.2280 2 EA
1307 1307 6"x3" x Eccentric Reducer X 150# Item 120.C.2290 1 EA
1308 1308 4"x3" x Eccentric Reducer X 150# Item 120.C.2300 1 EA
1309 1309 4"x2.5" x Eccentric Reducer X 150# Item 120.C.2310 1 EA
1310 1310 4"x2" x Eccentric Reducer X 150# Item 120.C.2320 1 EA
1311 1311 3"x2" x Eccentric Reducer X 150# Item 120.C.2330 1 EA
1312 1312 14"x12" x Concentric Reducer x 150# Item 120.C.2340 2 EA
1313 1313 14"x10" x Concentric Reducer x 150# Item 120.C.2350 2 EA
1314 1314 14"x8" x Concentric Reducer x 150# Item 120.C.2360 2 EA
1315 1315 12"x10" x Concentric Reducer x 150# Item 120.C.2370 2 EA
1316 1316 12"x8" x Concentric Reducer x 150# Item 120.C.2380 2 EA
1317 1317 12"x6" x Concentric Reducer x 150# Item 120.C.2390 2 EA
1318 1318 10"x8" x Concentric Reducer X 150# Item 120.C.2400 2 EA
1319 1319 10"x6" x Concentric Reducer X 150# Item 120.C.2410 2 EA
1320 1320 8"x6" x Concentric Reducer x 150# Item 120.C.2420 2 EA
1321 1321 8"x4" x Concentric Reducer x 150# Item 120.C.2430 2 EA
1322 1322 6"x4" x Concentric Reducer X 150# Item 120.C.2440 2 EA
1323 1323 6"x3" x Concentric Reducer X 150# Item 120.C.2450 2 EA
1324 1324 6"x2" x Concentric Reducer x 150# Item 120.C.2460 2 EA
1325 1325 4"x3" x Concentric Reducer X 150# Item 120.C.2470 2 EA
1326 1326 4"x2" x Concentric Reducer X 150# Item 120.C.2480 2 EA
1327 1327 Supply and delivery of pipe fittings at respective stations as per Station wise Break up of material supply and as per technical sp ecifications from approved vendors specified in tender document: 3"x2" x Concentric Reducer X 150#_E.233 Item 120.C.2490 2 EA
1328 1328 3"x1" x Concentric Reducer X 150# Item 120.C.2500 2 EA
1329 1329 2"x1" x Concentric Reducer x 150# Item 120.C.2510 2 EA
1330 1330 8"X6" x 300# Concentric Reducer -ASTM A 234 WPB Item 120.C.2520 4 EA
1331 1331 6"X4" x 300# Concentric Reducer -ASTM A420 Gr.WPL6 Item 120.C.2530 4 EA
1332 1332 14"x8" x Concentric Reducer x 600# Item 120.C.2540 4 EA
1333 1333 12"x8" x Concentric Reducer x 600# Item 120.C.2550 2 EA
1334 1334 8"x6" x Concentric Reducer x 600# Item 120.C.2560 6 EA
1335 1335 8"x4" x Concentric Reducer x 600# Item 120.C.2570 2 EA
1336 1336 1" size 3000# St. NIPPLE Item 120.C.2580 125 EA
1337 1337 1" 3000# HALF COUPLING Item 120.C.2590 125 EA
1338 1338 14"x2" X 600# Weld-o-let Item 120.C.2600 8 EA
1339 1339 12"x2" x 600# Weld-o-let Item 120.C.2610 10 EA
1340 1340 8"x2" x 600# Weld-o-let Item 120.C.2620 15 EA
1341 1341 6"x2" x 600# Weld-o-let Item 120.C.2630 6 EA
1342 1342 8"x2" x 300# Weld-o-let Item 120.C.2640 6 EA
1343 1343 6"x2" x 300# Weld-o-let Item 120.C.2650 2 EA
1344 1344 12"x3" x 150# Weld-o-let Item 120.C.2660 4 EA
1345 1345 12"x2" x 150# Weld-o-let Item 120.C.2670 8 EA
1346 1346 10"x3" x 150# Weld-o-let Item 120.C.2680 4 EA
1347 1347 10"x2" x 150# Weld-o-let Item 120.C.2690 4 EA
1348 1348 8"x3" x 150# Weld-o-let Item 120.C.2700 4 EA
1349 1349 8"x2" x 150# Weld-o-let Item 120.C.2710 4 EA
1350 1350 6"x2" x 150# Weld-o-let Item 120.C.2720 4 EA
1351 1351 Supply of ASTM A106 Gr.B /A333 pipes at respective stations as per Station wise Break up of material supply and as per technical sp ecifications from approved vendors specified in tender document. Item 120.C.2730
1352 1352 4.500" ODx 0.237" WT (Sch.STD) ASTM A 106 Gr B bare Pipe Item 120.C.2740 120 M
1353 1353 3.500" ODx 0.216" WT (Sch.STD) ASTM A 106 Gr B Item 120.C.2750 80 M
1354 1354 2.375" ODx 0.218" WT (Sch.XS) ASTM A 106 Gr B bare pipe Item 120.C.2760 150 M
1355 1355 1.315" ODx 0.179"WT (Sch.XS) ASTM A 106 Gr B Bare pipe Item 120.C.2770 140 M
1356 1356 6.625" ODx 0.280" WT (Sch.STD) ASTM A 333 Gr 6 bare Pipe Item 120.C.2780 40 M
1357 1357 4.500" ODx 0.237" WT (Sch.STD) ASTM A 333 Gr 6 bare Pipe Item 120.C.2790 70 M
1358 1358 3.500" ODx 0.216" WT (Sch.STD) ASTM A 333 Gr 6 Item 120.C.2800 390 M
1359 1359 2.375" ODx 0.218" WT (Sch.XS) ASTM A 333 Gr 6 bare pipe Item 120.C.2810 150 M
1360 1360 1.315" ODx 0.179"WT (Sch.XS) ASTM A 333 Gr 6 Bare pipe Item 120.C.2820 200 M
1361 1361 Flame Arrestor:Supply and delivery of following mentioned Flame Arrestor at respective stations as per Station wise Break up of mate rial supply and as per technical specifications indicated in tender docuemnts: 4" Flame Arrester Item 120.C.2830 4 EA
1362 1362 Supply of IS: 3589, Gr. Fe 410 pipes with factory coated internal coating at respective stations as per Station wise Break up of mat erial supply and as per technical specifications from approved vendors specified in tender document Item 120.C.2840
1363 1363 14" ODx 0.250" WT IS3589 FE410 Pipe Sch. 10 Item 120.C.2850 50 M
1364 1364 12.75" ODx 0.25" WT IS3589 FE410 Pipe Sch. 20 Item 120.C.2860 1180 M
1365 1365 10.75" ODx 0.25" WT IS3589 FE410 Pipe Sch. 20 Item 120.C.2870 40 M
1366 1366 8.625" ODx 0.250" WT IS3589 FE410 Pipe Sch. 20 Item 120.C.2880 40 M
1367 1367 6.625" ODx 0.250" WT IS3589 FE410 Pipe Sch. 20 Item 120.C.2890 40 M
1368 1368 Supply of Valves at respective stations as per technical specifications from approved vendors in the tender document -FOR FIRE WATER NETWORK. Item 120.C.2900
1369 1369 14"x ANSI 150# HOV F/F API 600 Gate Valve FW Item 120.C.2910 1 EA
1370 1370 12"x ANSI 150# HOV F/F API 600 Gate Valve FW Item 120.C.2920 24 EA
1371 1371 10"x ANSI 150# HOV F/F API 600 Gate Valve FW Item 120.C.2930 4 EA
1372 1372 8"x ANSI 150# HOV F/F API 600 Gate Valve FW Item 120.C.2940 4 EA
1373 1373 6"x ANSI 150# HOV F/F API 600 Gate Valve FW Item 120.C.2950 2 EA
1374 1374 4"x ANSI 150# HOV F/F API 600 Gate Valve FW Item 120.C.2960 35 EA
1375 1375 3"x ANSI 150# HOV F/F API 600 Gate Valve FW Item 120.C.2970 5 EA
1376 1376 2"x ANSI 150# HOV F/F API 600 Gate Valve FW Item 120.C.2980 5 EA
1377 1377 1"x ANSI 800# HOV W/W API 602 Gate Valve FW Item 120.C.2990 16 EA
1378 1378 "Supply of Valves at respective stations as per technical specifications from approved vendors in the tender document - Globe Valves " Item 120.C.3000
1379 1379 12"x ANSI 600# F/F BS-1873 GLOBE Valve Item 120.C.3010 1 EA
1380 1380 8"x ANSI 600# F/F BS-1873 GLOBE Valve Item 120.C.3020 8 EA
1381 1381 6"x ANSI 600# F/F BS-1873 GLOBE Valve Item 120.C.3030 4 EA
1382 1382 4"x ANSI 600# F/F BS-1873 GLOBE Valve Item 120.C.3040 1 EA
1383 1383 2"x ANSI 600# F/F BS-1873 GLOBE Valve Item 120.C.3050 20 EA
1384 1384 8"x ANSI 300# F/F BS-1873 GLOBE Valve Item 120.C.3060 1 EA
1385 1385 6"x ANSI 300# F/F BS-1873 GLOBE Valve Item 120.C.3070 1 EA
1386 1386 2"x ANSI 300# F/F BS-1873 GLOBE Valve Item 120.C.3080 4 EA
1387 1387 1"x ANSI 800# W/W ISO 15761 GLOBE VALVE Item 120.C.3090 70 EA
1388 1388 14"x ANSI 600# F/F BS-1873 GLOBE Valve Item 120.C.3100 1 EA
1389 1389 3"x ANSI 600# F/F BS-1873 GLOBE Valve Item 120.C.3110 9 EA
1390 1390 3"x ANSI 300# F/F BS-1873 GLOBE Valve Item 120.C.3120 2 EA
1391 1391 Supply of Valves at respective stations as per technical specifications from approved vendors in the tender document - BS 1868 Swing Check Valves Item 120.C.3130
1392 1392 8"x ANSI 150# F/F BS-1868 Swing Check Valve Item 120.C.3140 1 EA
1393 1393 4"x ANSI 150# F/F BS-1868 Swing Check Valve Item 120.C.3150 1 EA
1394 1394 3"x ANSI 150# F/F BS-1868 Swing Check Valve Item 120.C.3160 1 EA
1395 1395 2"x ANSI 150# F/F BS-1868 Swing Check Valve Item 120.C.3170 1 EA
1396 1396 Supply of Valves at respective stations as per technical specifications from approved vendors in the tender document - Thermal Relie f Valves Item 120.C.3180
1397 1397 1" x 1" 600# x300# F/F TRV Item 120.C.3190 49 EA
1398 1398 1" x 1" 300# x300# F/F TRV Item 120.C.3200 16 EA
1399 1399 Supply of Fire Fighting Monitor/hydrant Item 120.C.3210
1400 1400 High Volume Long Range HVLR Foam Monitor 750 GPM capacity stand post type with inlet flange of 4" X 150# Item 120.C.3220 11 EA
1401 1401 Stand Post Type double way fire hydrant fitted with 2 Nos of single landing valve complete as per IS: 5290 alongwith 4" x 150# WNRF Flange Item 120.C.3230 36 EA
1402 1402 Supply and delivery of Fire Fighting Equipment at respective stations as per Station wise Break up of material supply and as per tec hnical specifications from approved vendors specified in tender document. Item 120.C.3240
1403 1403 Diesel Engine Driven Horizontal Centrifugal Pumping Unit For Water displacement/Fire Fighting System ( Q= 350 Kl/Hr and H= 150 MCL) with Spares and Commissioning Services Item 120.C.3250 1 EA
1404 1404 Jockey Pump Unit with Q-10 Kls/Hr, H-105 MCL with Spares and Commissioning Services as per technical specifications Item 120.C.3260 1 EA
1405 1405 Vertical Submersible type Motor Driven Water filling Pumping Unit with Spares and Commissioning Services as per technical specific ations. (Q=30 Kl/Hr.,H= 40 MCL) Item 120.C.3270 1 EA
1406 1406 9 kg DCP Extinguisher Item 120.C.3280 22 EA
1407 1407 4.5 kg CO2 Extinguisher Item 120.C.3290 16 EA
1408 1408 2 kg CO2 Extinguisher Item 120.C.3300 32 EA
1409 1409 2.5 kg clean agent extinguishers IS 15683 Marked Item 120.C.3310 12 EA
1410 1410 2 kg clean agent extinguishers IS 15683 Marked Item 120.C.3320 8 EA
1411 1411 Fire Hose Box for keeping 2 Nos. of 15 M Type B delivery hose and one no. jet nozzle Item 120.C.3330 22 EA
1412 1412 Type B Delivery Hoses of 15 M length bearing IS-636 mark Item 120.C.3340 56 EA
1413 1413 Jet Nozzles Item 120.C.3350 28 EA
1414 1414 Fog Nozzle Item 120.C.3360 4 EA
1415 1415 Universal Nozzle Item 120.C.3370 4 EA
1416 1416 Water curtain nozzle Item 120.C.3380 4 EA
1417 1417 Sand drum with scoop Item 120.C.3390 16 EA
1418 1418 Pair of Rubber hand gloves for Electrical work bearing IS mark Item 120.C.3400 8 EA
1419 1419 First Aid Box with Snake serum Item 120.C.3410 4 EA
1420 1420 Fire Bucket Item 120.C.3420 16 EA
1421 1421 Safety Helmet Item 120.C.3430 32 EA
1422 1422 Strecher WITH BLANKET Item 120.C.3440 4 EA
1423 1423 Explosimeter Item 120.C.3450 6 EA
1424 1424 Rescuscitor Item 120.C.3460 4 EA
1425 1425 Electrical Siren Item 120.C.3470 2 EA
1426 1426 Hand Operated siren Item 120.C.3480 4 EA
1427 1427 Water gel blanket Item 120.C.3490 6 EA
1428 1428 Positive Pressure type self containing Breathing Apparatus Item 120.C.3500 4 EA
1429 1429 Safety Torch Item 120.C.3510 8 EA
1430 1430 Fire Proximity suit Item 120.C.3520 4 EA
1431 1431 Wind socks Item 120.C.3530 12 EA
1432 1432 PA system/ Loudhailer/ megaphone Item 120.C.3540 2 EA
1433 1433 Red & Green flag (Pairs) 2 nos in each colour Item 120.C.3550 8 EA
1434 1434 Extinguisher box for 9 kg DCP Extinguishers Item 120.C.3560 14 EA
1435 1435 Dry Chemical Powder silliconised potassiun bicarbonate type IS marked, pack in 10Kg Item 120.C.3570 240 EA
1436 1436 CO2 cartridge - 200 gm capacity for 9 kg Item 120.C.3580 16 EA
1437 1437 Low temparature rubber hand gloves Item 120.C.3590 12 EA
1438 1438 Low temparature protective clothing Item 120.C.3600 6 EA
1439 1439 Emergency Kit: Supply and delivery of Emergency Kit consisting oflisted emergency equipments as per Annexure-VII Item 120.C.3610 4 EA
1440 1440 Corrosion Coupon: Supply of TOR Fitting Complete With Plug & Cap and Full bore Threaded Ball Valve Item 120.C.3620
1441 1441 TOR fitting complete with Caps, Plugs, O-Rings, Nipple & 2" 600# full bore threaded ball valve. Item 120.C.3630 9 EA
1442 1442 RETRACTABLE CORROSION COUPON HOLDER, 8" Item 120.C.3640 1 EA
1443 1443 RETRACTABLE CORROSION COUPON HOLDER, 12" Item 120.C.3650 2 EA
1444 1444 RETRACTABLE CORROSION COUPON HOLDER, 6" Item 120.C.3660 2 EA
1445 1445 RETRACTABLE CORROSION COUPON HOLDER, 14"" Item 120.C.3670 2 EA
1446 1446 Supply of Y-type strainer(Cast /Plate Fabricated Body), F/F connection, as per below mentioned sizes & rating and flow detail and as per technical specifications indicated in tender documents. ( Each strainer shall be supplied with 1 set of companion WNRF Flanges, Gaskets & Fasteners,02 Nos. cover Gaskets, 1 filter element Item 120.C.3680
1447 1447 Y-type Strainer 10" x ANSI 150# Item 120.C.3690 2 EA
1448 1448 Y-type Strainer 4" x ANSI 150# Item 120.C.3700 1 EA
1449 1449 Y-type Strainer 3" x ANSI 150# Item 120.C.3710 1 EA
1450 1450 Supply and delivery of BS 5351/ISO 17292 Ball valve for use in process piping at respective stations as per Station wise Break up o f material supply and as per technical specifications from approved vendors specified in tender document. 1" x 800# Ball valve HOV W /W ISO 17292 Item 120.C.3720 101 EA
1451 1451 Supply and delivery of API 6D Ball valves for use in process piping at respective stations as per Station wise Break up of material supply and as per technical specifications from approved vendors specified in tender document. Item 120.C.3730
1452 1452 2" F/F ANSI 600# A/G, API6D BALL VALVE HOV Item 120.C.3740 45 EA
1453 1453 2" F/F ANSI 300# A/G, API6D BALL VALVE HOV Item 120.C.3750 10 EA
1454 1454 4" F/F ANSI 600# A/G, API6D BALL VALVE HOV Item 120.C.3760 4 EA
1455 1455 3" F/F ANSI 600# A/G, API6D BALL VALVE HOV Item 120.C.3770 8 EA
1456 1456 3" F/F ANSI 300# A/G, API6D BALL VALVE HOV Item 120.C.3780 4 EA
1457 1457 Supply and delivery of BS 5351 Ball valve for use in air line at respective stations as per Station wise Break up of material suppl y and as per technical specifications from approved vendors specified in tender document Item 120.C.3790
1458 1458 2" F/F ANSI 300# A/G, BALL VALVE BS 5351 Air Line HOV Item 120.C.3800 7 EA
1459 1459 1" W/W ANSI 800# A/G, BALL VALVE BS 5351 Air Line HOV Item 120.C.3810 12 EA
1460 1460 1" F/F ANSI 600# A/G, BALL VALVE BS 5351 Air Line HOV Item 120.C.3820 1 EA
Disclaimer :