| Name of Work: SPECIAL REPAIR TO BLDG NO T-3 UNDER GE NARANGI | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Taking down roof trusses, coupling rafters of clear span above 4m & upto 8 m complete all as specified and directed. | 11 | Each Span | |
| 2 | 2 | Dismantling hearth or wall tiling of any description, size and thickness including cement mortar bedding (but not backing), removing rubbish off the premises etc complete all as specified and directed. | 230 | Sqm | |
| 3 | 3 | Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles and removing rubbish off the premises etc complete all as directed. | 95 | Cum | |
| 4 | 4 | Demolition of Concrete of any description and in any position not otherwise specifically provided and removing rubbish off the premises etc complete all as directed. | 16 | Cum | |
| 5 | 5 | Demolition of RCC (reinforced) of any description and any position not otherwise specifically provided and removing rubbish off the premises etc complete all as directed. | 20.5 | Cum | |
| 6 | 6 | Dismantling of timber scantlings 40 sq. cm and over in section, unframed work, in any position etc complete all as directed. | 2.5 | Cum | |
| 7 | 7 | Dismantling timber scantling under 40sqcm in section in fillets, rails, rafter, purlins etc fixed with nails/screw etc complete all as directed. | 64 | RM | |
| 8 | 8 | Dismantling of timber and ceiling boards of any sizes any thickness fixed with screws etc complete all as directed. | 142 | Sqm | |
| 9 | 9 | Dismantling of asbestos cement (corrugated, semi corrugated, etc) sheets in roof covering complete all as directed. | 280 | Sqm | |
| 10 | 10 | M&L for hardcore of broken stone or boulders of gauge n exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface etc complete all as directed. | 19 | Cum | |
| 11 | 11 | M&L for PCC 1:3:6 type C2 (40mm graded stone aggregate) in foundation filling and mass concrete etc complete all as directed. | 1 | Cum | |
| 12 | 12 | M&L for reinforced cement concrete 1:1½:3 type A1(20mm graded stone aggregate) nominal mix as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc, basement slabs, under-reamed piles and mass concrete etc complete all as directed. | 8 | Cum | |
| 13 | 13 | All as per item No 12 above but in beams, seismic bands, cantilevers, bressumers and lintels . | 9 | Cum | |
| 14 | 14 | All as per item No 12 above but in columns. | 3.5 | Cum | |
| 15 | 15 | Supply only integral water proofing compound | 35.5 | Kg | |
| 16 | 16 | M & L for brick work with sub class B bricks straight or curved on plan exceeding 6m mean radius built in CM 1:6 complete all as specified and as directed. | 83 | Cum | |
| 17 | 17 | All as per item No 16 above but except bricks. | 12 | Cum | |
| 18 | 18 | Use and waste of form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work; vertical or to batter, horizontal or sloping flat rough finished surfaces of concrete | 33 | Sqm | |
| 19 | 19 | All as per item No 18 above but formwork to sides and soffits of floor or roof beams, beams haunchings, girders, bressumers, lintels, cantilevers, shelves including supports overhangs etc also splays between floors and beams etc flat rough finished surfaces of concrete | 33 | Sqm | |
| 20 | 20 | All as per item No 18 above but formwork to sides of pillars, posts, struts, piers, columns and stanchions | 30 | Sqm | |
| 21 | 21 | S&F 20mm thick 2nd class hardwood planed one side fixed with butt joints for eaves board etc complete all as directed. | 20 | Sqm | |
| 22 | 22 | S&F 35mm thick 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitered beds for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.20 (a); supplied and fitted to chowkats | 20 | Sqm | |
| 23 | 23 | S&F 30mm thick flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides etc complete all as directed. | 20 | Sqm | |
| 24 | 24 | S&F 150 mm size aluminum anodized barrel tower bolts of extruded sections, with cast or sheet barrel and rolled or cast bolts etc complete all as directed. | 40 | Each | |
| 25 | 25 | S & F aluminum alloy, anodized, sliding door bolt with hasp, staple & fixed clips of sheet, cast or extruded section & fixed bolts & sliding bolts of extruded section or cast aluminum alloy, length of bolt 300 mm etc complete all as directed. | 20 | Each | |
| 26 | 26 | S&F 100mm size MS butt hinges, cast brass, with stainless steel hinge pin, bright polished and fixed etc complete all as directed. | 60 | Each | |
| 27 | 27 | S&F steel helical door spring 300mm size rat tail rod pattern spring, including roller and roller plate complete all as directed. | 10 | Each | |
| 28 | 28 | S & F 150 mm size extruded aluminum handles fabricated type, anodized and polished etc complete all as directed. | 40 | Each | |
| 29 | 29 | S&F in repairs powder coated aluminum alloy curtain rails 20mm dia including fancy brackets and clamps fixed to required lengths etc complete all as directed. | 18 | RM | |
| 30 | 30 | S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples etc complete all as directed. | 18 | Sqm | |
| 31 | 31 | S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1998 complete all as specified and directed. | 3860 | Kg | |
| 32 | 32 | S&F Mild steel of conforming to Fe 290 grade E-165 as in wind ties fixed at eaves and ridge level etc complete all as directed. | 110 | Kg | |
| 33 | 33 | S&F Mild steel of conforming to Fe 290 grade E-165 as framed work (Angles ,Flat Iron, square/round bars) with ends of bars shouldered and/or riveted or forged into spikes for window grills/framed guard bars to the design and pattern of ornamental and intricate as approved etc complete all as specified and directed. | 150 | Kg | |
| 34 | 34 | M&L for mild steel bars 10mm dia and over TMT bars, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia | 2260 | Kg | |
| 35 | 35 | All as per item No 34 above but 5mm dia and over upto 10mm dia as in stirrups, spacers and binders | 1460 | Kg | |
| 36 | 36 | S&F steel windows with side hung shutters both mosquito proof and glazed shutter including projecting type hinges with steel handle and steel peg stay with glazing bars and 12 mm square bar or ground bar of approved design welded to steel window frame dovetailed or welded complete all as directed. | 12 | Sqm | |
| 37 | 37 | S&F mild steel pressed steel frames of size 125x60mm , 1.25 mm thick for doors, double rebates including necessary fixing lugs, hinges, lock strike plate, including filling the hollow portions of steel frame with PCC 1:2:4 type B-0 (12.5mm graded stone aggregate) etc complete all as directed. | 52 | RM | |
| 38 | 38 | Providing & fixing false ceiling of Designer tile Ivory painted (High Pressure Steam cured) of 4mm thickness (as per IS : 14862) of size 595x595mm and any one of the design (Cascade or electra) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel section (Galvanized @120 grams, both side inclusive and black painted groove on all T webs) consisting of main T runner with suitably spaced joints to get required length and 15x32mm made from 0.30mm thick sheet spaced at 1200mm c/c and cross 'T' of size 15x32mm made of 0.30mm sheet 1200mm long spaced between main \"T\" at 600 mm c/c to form a grid of 1200x600mm and secondary cross \"T\" of length 600mm and size 15x32 mm made of 0.30mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x22x0.40mm and laying false ceiling tiles in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \"T\" runners to be suspended from trusses/ceiling using suitable suspension arrangement as per manufacturers instructions/literature, GI adjustable wire of 4mm dia with galvanized butterfly level clips, spaced at 1200mm c/c along main 'T', bottom exposed width of 15mm of all 'T'' sections of 4mm dia GI wire shall be pre-painted with polyester paint and black painted groove at centre of size 4mm depth and 4.5mm width, all complete at all heights as per direction of Engr-in-Charge. | 142 | Sqm | |
| 39 | 39 | S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as directed. | 260 | Sqm | |
| 40 | 40 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as directed. | 20 | Sqm | |
| 41 | 41 | M&L for PCC 1:3:6 type C2 (using 40 mm graded aggregate) as in plinth protection 75mm thickness, finished even and smooth using extra cement including 10mm wide and 30mm deep joints at every 2.4mtrs interval filled with mastic compound etc complete all as specified and as directed by Engr-in-Charge. | 58 | Sqm | |
| 42 | 42 | M&L for 100mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in subase finished to receive floor treatment / chequered tiles etc complete all as directed. | 60 | Sqm | |
| 43 | 43 | M&L for 25mm thick PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in subase finished to receive floor treatment and to finish the surface leveled etc complete all as directed. | 200 | Sqm | |
| 44 | 44 | M&L for coloured Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc. with and including 15mm thick screed bed in CM 1:4 ,set and jointed in neat cement slurry and pointed in white or coloured cement to match etc complete all as directed. | 200 | Sqm | |
| 45 | 45 | All as per item No. 44 above but in vertical surfaces such as skirting and dado, laid over and including 10 mm thick rendering in CM 1:4. | 30 | Sqm | |
| 46 | 46 | M&L for pre-polished chequered cement concrete tiles of size 300mm x 300mm x 25mm thick made of grey cement with pigment, laid over and including 15mm thick CM 1:6 bedding, set and jointed in neat cement slurry and pointed in coloured cement to match etc complete all as directed. | 60 | Sqm | |
| 47 | 47 | M&L for 15 mm thick rendering in CM 1:6 on brick/ concrete surfaces and finishing the surfaces even and smooth without using extra cement etc complete all as directed. | 500 | Sqm | |
| 48 | 48 | M&L for 15 mm thick rendering in CM 1:4 on brick/concrete external surfaces and finishing the surfaces even and smooth without using extra cement etc complete all as directed.\n | 130 | Sqm | |
| 49 | 49 | M&L for preparation of newly plastered surfaces of walls and applying one coat of alkali resistant primer over a coat of white cement based putty and finally applying two coats of oil emulsion distemper etc complete all as directed. | 500 | Sqm | |
| 50 | 50 | M&L for preparation of new plastered surfaces of wall, any description, washing rubbing down and applying two coats exterior acrylic emulsion paint ( 1st quality) over a coat of suitable exterior primer complete all as specified and directed. | 130 | Sqm | |
| 51 | 51 | S&F 3 mm thick sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 sq. m in each pane etc complete all as directed | 5.5 | Sqm | |
| 52 | 52 | M & L for preparation of new or previously untreated wooden surfaces of any description, not otherwise described, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer on wooden surfaces complete all as specified and directed. | 36 | Sqm | |
| 53 | 53 | M & L for preparation of new or previously untreated steel surfaces of any description, not otherwise described, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed . | 23 | Sqm | |
| 54 | 54 | All as per item no 53 above but not exceeding 10cm width or girth. | 6 | XRM | |
| 55 | 55 | S&F in repair 600x450mm , 6 mm thick beveled edge mirror of selected quantity glass, moulded on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated screws and cup washers complete all as specified and as directed. Make of mirror : Modiguard/Atul/Saint-Gobain | 10 | Each | |
| 56 | 56 | Taking down chowkhat or frame with shutter (without taking off shutter from the frame) not exceeding 1.5 sqm each and making good to the disturbed surfaces and removing unserviceable materials from site of work complete all as directed by the Engineer-in-Charge. | 10 | Each | |
| 57 | 57 | Taking down chowkhat or frame with shutter (without taking off shutter from the frame) exceeding 1.5 sqm but not exceeding 4 sqm each and making good to the disturbed surfaces and removing unserviceable materials from site of work complete all as directed by the Engineer-in-Charge. | 10 | Each | |
| 58 | 58 | Taking down carefully aluminum point wiring (light, fan socket or power) complete including fittings & fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. and making good disturbed surfaces of walls, floors etc complete all as directed. | 60 | Each Point | |
| 59 | 59 | M&L point wiring with 1.5 Sqmm (nominal area) PVC insulated1100 volts grade, multistranded, copper conductor, single core, unsheathed cables (FRLS quality) drawn through and including PVC conduits of suitable size but not less than 20 mm dia (medium grade) with all fittings and accessories concealed in walls/ceiling etc including cutting chases for conduits and sinking for boxes and making good to disturbed surfaces including sunk mild steel terminal box with 3mm thick plastic laminated sheet top cover for mounting switches, sockets, regulators etc including PVC insulated and unsheathed, single core, multi-stranded, copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for one light point / fan point/ one call bell point controlled by one 5 Amps one way switch complete as specified and directed. Note : Quoted rate shall be included for necessary chasing and cutting and making good . | 40 | Each Point | |
| 60 | 60 | All as per item No 59 above but one 3 pin socket outlet 5 Amps, on the same board with other switches. | 8 | Each Point | |
| 61 | 61 | All as per item No 59 above but one 3 pin socket outlet 5 Amps, on independent board. | 16 | Each Point | |
| 62 | 62 | All as per item No 59 here-in-before but point wiring for one 3/5 pin 15 Amps socket point on independent board with 2.5 Sqmm size PVC insulated, unsheathed, multi stranded, copper conductor cables and with 2.5 Sqmm PVC insulated unsheathed, single core, multistranded copper conductor cable as earth wire complete as specified and directed. | 4 | Each Point | |
| 63 | 63 | Supply and fixing bell push,6 Amp, flush type, single pole, one way 230 volts, complete all as specified and directed. | 8 | Each | |
| 64 | 64 | Supply and fixing switch piano,6 Amp, flush type, single pole, one way 230 volts, complete all as specified and directed. | 44 | Each | |
| 65 | 65 | S & F socket outlet 5 Amps,3/5 pin flush type complete all as specified and directed. | 8 | Each | |
| 66 | 66 | S & F switch socket combination 2 in 1, 5 Amps, 3/5 pin, flush type complete all as specified and directed. | 16 | Each | |
| 67 | 67 | S & F switch socket combination 2 in 1, 3/5 pin, 5 and 15/16 Amps, flush type complete all as specified and directed. | 4 | Each | |
| 68 | 68 | S & F ceiling rose, 3 phase/PVC/polycarbonate, isolated body complete all as specified and directed. | 32 | Each | |
| 69 | 69 | S & F stepped type electronic fan regulator, flush type (ISI mark), 240 volts complete all as specified and directed. | 8 | Each | |
| 70 | 70 | S & F lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified and directed. | 18 | Each | |
| 71 | 71 | Supply and fixing 15 watt LED recessed mounted luminaire with high brightness LED for glare- free homogenous illumination suitable for armstrong/grid ceiling and size in mm (LxWxH) 295x295x70 mm and connection complete all as specified and directed. Make : Havells cat Part No : PLUTO1x1PLR15WLED840S/PLUTO1x1PLR15WLED857S or equivalent in Philips/Bajaj/Jaquar. | 8 | Each | |
| 72 | 72 | Supply and fixing wall mounted LED box type fitting, 1 x 20 watt, extruded aluminum heat sink provided for efficient heat dissipation and integrated electronic driver light fittings 20 watt fixed to wall with two Nos PVC block of suitable size and connection complete all as specified and directed. Make : Havells cat Part No : LHEXBYPNIN1W020 or Jaquar Cat No LGLZ01X020XC/LGLZ01X20XN/LGLZ01X020XW or equivalent in Philips/Bajaj. | 24 | Each | |
| 73 | 73 | Supply and fixing bell push, flush type one way 240 Volts 5 Amps all as specified. | 8 | Each | |
| 74 | 74 | S&F Sheet metal enclosure (DB) for housing MCBs, 8 way, SPN, double door, 415 Volts, with 100 Amp rated bus bar including cutting chases for sinking for boxes and making good to disturbed surface complete as specified and directed. | 2 | Each | |
| 75 | 75 | S&F MCB, single pole, 6 to 32 Amps, 50Hz \"C\" curve complete as specified and directed. | 12 | Each | |
| 76 | 76 | S&F MCB, SPN, 40 to 63 Amps, 50Hz \"C\" curve complete as specified and directed. | 2 | Each | |
| 77 | 77 | M&L Earthing complete with galvanized steel earth plate electrode 60cmx60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 m deep below normal ground level, connected to GI earth lead wire 4.0 mm dia means of nuts, bolts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 connected to earthing test point protected by and including GI pipe 15 mm bore (light grade) and connected to main test point as directed and including concrete pit in PCC (1:3:6) type C-1,pre cast RCC (1:1½:3) type A-1 cover slab 54cm x 54cm x 5 cm, reinforced with 8mm dia TMT bars @ 150 mm C/C both ways with one handle for lifting, made out of 8mm dia TMT bar embedded in pre cast cover slab , funnel, wire mesh, 20 mm bore GI pipe (medium grade) for watering, charcoal and salt in alternate layers, including necessary excavation and earth work in any type of soil complete all as shown on electrical Plate No 3 of SSR Part-I, and testing complete all as specified and as directed . | 2 | Each Job | |
| 78 | 78 | M&L in repair sub main wiring with 2 runs of 4 Sqmm single core, PVC insulated, unsheathed 1100 Volts grade, multi-stranded, copper conductor cables (FRLS quality) drawn through and including suitable size medium grade PVC conduit with fitting/accessories as required concealed in walls/ceiling etc including cutting chases for conduits and making good to disturbed surfaces including 4 Sqmm PVC insulated, unsheathed, multistranded, copper conductor, single core cable as earth continuity wire with all fittings complete as specified and directed. Note: Two run of single core cable, conduit pipe and one run earth wire will be measured as one length. | 50 | RM |
AI Tender Summary
Tender Timeline
Apr 16, 2020
11:30 IST
Tender Published
Tender notice published.
CompletedMay 09, 2020
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedMay 11, 2020
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender