Repair And Overhauling Of Ceilling Fan , Geyser At Dronachal Bottom Bhopal , Taking Down Unsv Ceiling Fan/Exhaust Fans/Wall Mounting Fan Of Any Cap/Sweep After Disconnecting The Electric Supply From Any Site And Opening Fans For Repair/Over Hauling Including Removing Dust And Grease , And Cleaning Of Blads And Fan With Kerosene Oil And Checking Of Alignment Of Shaft , Oiling Including Re-Assembling , And Connecting/Refixing Of Fans In Its Original Position Burnt Out Fan Shall Be Kept Separately For Rewinding Complete All As Specified And Directed By Engr-In-Charge . Note: Rewinding And Replacement Of Defective Parts Shall Be Measured And Paid Seperately . , M&L For Rewinding Ceiling Fan Of Sweep 1200 Mm With Suitable Gauge Copper Winding Wire ( Super Enamelled ) Including All Insulating Material After Necessary Heat Varnishing Testing Etc . Complete All As Specified And Directed By Engr-In-Charge . , M&L For Rewinding Ceiling Fan Of Sweep 1400 Mm With Suitable Gauge Copper Winding Wire ( Super Enamelled ) After Necessary Heat Varnishing Testing Etc . Complete All As Specified And Directed By Engr-In-Charge . , M&L For Rewinding Exhaust Fan Of Sweep 250/300 Mm With Suitable Gauge Copper Winding Wire ( Super Enamelled ) Including All Insulating Material After Necessary Heat Varnishing Testing Etc . Complete All As Specified And Directed By Engr-In-Charge . , Taking Down And Dismantling The Outer Cover Of Geyser Of Any Capacity And Removing The Scaling Including Repairing And Replacement Of The Inlet And Out Let Pipe And Re-Assembling The Same After Testing Complete All As Specified And Directed By Engr-In-Charge . , Taking Out And Repalcement Of Following Unserviceable Parts Of Geyser :- , ( A ) Inner Tank Copper 25 Ltrs Cap Isi Marked , ( B ) Thermostat Isi Marked , ( C ) Triangle Heating Element 1 . 5 Kw , Isi Marked Complete , ( D ) Indicator Lamp With Flexibe Copper Wire Of Suitable Size Red/Green , ( E ) Pvc Connection With Steel Reinforced Pipe For Hot Water Connection Of Size 18 X 1/2 , M & L For Painting Of Following Item With Two Coats Of Best Quality Paint ( Isi Grade ) White Using Spray Machine Spray Painting Including Cleaning , Washing And Preparation Of Old Painted Surfaces Including Mes Nos Shall Be Entered In All Ceiling And Exhaust Fan In Site Only , Complete All As Directed By Engr-In-Charge:-Note:- ( Painting Shall Be Carried Out In E/M Yard ) , ( A ) Ceiling Fan Upto 1200/1400 Mm Sweep Complete . , ( B ) Exhaust Fan Upto 300/380/450 Mm Sweep With Smoke Grey . , ( C ) Geyser 25 Liter Cap . , ( D ) Geyser 50 Liter Cap . , Supply And Fixing In Repair Metal Fan Blade Of Any Type And Any Size Suitable For Wall Mounting Fan/Ceiling Fan Complete All As Specified And Directed By Engineer-In-Charge . , Supply And Fixing In Repair Metal Fan Blade Of Any Type And Any Size Suitable For Exhaust Fan Of Any Capacity , Of Any Make , Complete All As Specified And Directed By Engineer-In-Charge . , ( A ) 300Mm Sweep , ( B ) 380Mm Sweep , ( C ) 450Mm Sweep , M&L For Fixing Of Geyser In Existing Or New Position By Providing Suitable Size Of Anchor Fastner And Connecting Pvc Flexible Inlet And Outlet Pipe Complete All As Specified And Directed By Engr-In-Charge . , M&L For Repairs To Defective/Leakage Of Geyser 25/50 Ltr Capacity Inner Tank Of Copper/Steel By Brazing , Soldering , Gas Welding Including Testing For Leak Proof Upto The Satisfaction Of The Eic . , Taking Out And Replacement Of Following Accessories Form Ceiling Fans Taking Down Vide Item No 1 Here In Before Complete All As Specified And Directed By Engr-In-Charge . , ( A ) Bearing No 6201 , ( B ) Bearing No 6202 , ( C ) Bearing No 6203 , ( D ) Rubber Bush , Nut , Bolts , Washer And Split Pin Etc Suitable For Ceiling Fan As Per Site Requirement , ( E ) Condenser 2 . 5 Mfd Make: Epcos/Tibcon , ( F ) Condenser 4 Mfd Make: Epcos/Tibcon , ( G ) Ceiling Fan Shaft , ( H ) Ceiling Fan Clamps , Supply And Fixing Ceiling Fan Regulator Isi Marked , Any Type Complete All As Specified And Directed , Supply And Fixing Ceilling Fan Down Rod Of Size 15Mm Gi Pipe Medium Grade ( Isi Mark ) Length Upto 50Cm Including Making Holes , Nut Bolts , Spilit Pin Washers Etc Complete All As Specified And Directed By Engr-In-Charge . . , S&F Gun Metal Half Turn Upvc Gate Valve Of 25Mm Dia And Fixed In Position After Taking Out Unserviceable Gate Valve Complete All As Specified And Directed By Engr-In-Charge . Make Zoloto , S&F Gun Metal Half Turn Upvc Gate Valve Of 20Mm Dia And Fixed In Position After Taking Out Unserviceable Gate Valve Complete All As Specified And Directed By Engr-In-Charge . Make Zoloto , Taking Down Fan Down From Existing Postion And Servicing , Gressing And Nut Bolt Checking And Refixing The Same Postion All As Per Directed By Engr-In-Charge . Note: Spare Parts Will Be Measured And Paid Sepertaly . Note For Item No 1 To 41 . Repairing/ Rewinding Of Ceilling Fan/ Exhaust Fan Shall Be Carried Out In The Age E/M Dronachal Subdivision In Present Of Concern Je E/M . 2 . Contractor Shall Detail The Staff To Collected Defective Fans From Concern Je E/M , Check The Fans After Opening It , And Intimate The Defects In The Fan To Je E/M Before Carring Out The Repairs . 3 . The Bearing Of Fan Should Be Of Nbc/Skf Make Only . No Other Make Will Be Accepted . 4 . Contractor Will Be Provided By Stciker Of Each Repairing Fan With Date And Name Of Frms . , S&F Ceiling Fan Canopy For Suitable Of 1200/1400 Mm Sweep Complete , Supply And Fixing Pvc Insulated Multistranded Copper Conductor , Sheated Round Cable Isi Marked 1 . 5 Sqmm X 3 Core Complete All As Specified And Directed By Engr-In-Charge . , Replacement Of Burning Wire Of Any Size Out Of Any Type Of Existing Dbs Including Replacement Of Damaged Pvc Conduit With Cement Work Complete . Note: Wire , Pvc Conduit And Cement Work Includeed In Quoted Rate . , M & L For Sheet Metal Enclosure With Socket And Plug Top Single Pole & Neutral With A Two Pin & Earth Plug & Socket Complete With One Mcb Sp 20 Amps , 240 Volts . , Supply And Replacement Of Switch Socket Combined Outlet 6 Pin Flush 15 Amp Multi , Isi Marked Complete All As Specified And Directed By Engr-In-Charge . , Material & Labour For Sub Main Wiring With Two Run Of Pvc Insulated Multi Stranded Copper Conductor Fire Retardant Cable 2 . 5 Sqmm Size ( Nominal Area ) And One Run Of Pvc Insulated Unsheathed Solid Core Copper Conductor Cable 1 . 5 Sqmm Size In Including Pvc Casing Capping Flat Pipe Of Required Size Complete All As Directed . , Material & Labour For Sub Main Wiring With Two Run Of Pvc Insulated Multi Stranded Copper Conductor Fire Retardant Cable 4 Sqmm Size ( Nominal Area ) And One Run Of Pvc Insulated Unsheathed Solid Core Copper Conductor Cable 2 . 5 Sqmm Size In Including Pvc Casing Capping Flat Pipe Of Required Size Complete All As Directed . , M&L , Rewinding Exhaust Fan Of Sweep 380/450 Mm With Suitable Gauge Copper Winding Wire ( Super Enamelled ) Including All Insulating Material After Necessary Heat Varnishing Testing Etc . Complete All As Specified And Directed By Engr-In-Charge . , M&L For 16 Amp Plastic Plug Top With Indicator Including All Insulating Material Etc . Complete All As Specified And Directed By Engr-In-Charge .