| 1 | 1 | Dismantling & Taking down existing ACSR conductor (any size) from LT poles and removing from site complete all as specified and directed. | 1 | 0.66 | Qtl |
|---|
| 2 | 2 | Dismantling insulators any type, any size incl GI spindle/ stapples complete and setting aside for re-use of serviceable quantity complete all as specified and directed.\nNOTE:(The serviceable quantity of insulators shall be returned to MES STORE) | 2 | 20 | Each |
|---|
| 3 | 3 | Dismantling Cross arms of MS channel or angle sections etc complete and setting aside for reuse of serviceable qty and removing unsv qty from site complete all as specified and directed. | 3 | 0.2 | Qtl |
|---|
| 4 | 4 | Taking down unserviceable / burnt street light/ flood light fittings of any type incl bracket from pole of any height and removing from site complete all as specified and directed. | 4 | 2 | Each |
|---|
| 5 | 5 | Taking down unserviceable /rusted steel electric pole of any make and any size from the site complete all as specified and directed. | 5 | 5 | Each |
|---|
| 6 | 6 | S & F steel tubular swaged poles erected truly vertical or planted as strut complete with 300 x300x 6 mm thick mild steel base plate, welded to pole, B-118 final, taper cap, bolts, nuts & screws, poles made out of ERW MS tubing conforming to IS-2713 Part-II. type 410-SP-31 (9.00 m long) including drilling of holes of reqd size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminium paint over a coat of red oxide zinc chrome primer and with two coats of black bitumenous paint internally & portion embedded in concrete, making five black & red bands at lower portion of pole each 300mm wide alternately, and marking pole No. with black paint at suitable height complete all as specified and directed. | 6 | 2 | Each |
|---|
| 7 | 7 | S & F PVC/Thermoplastic pole box fixed with steel tubular pole alongwith suitable size MS clamp duly painted including MCB SPN 10 Amps complete all as specified and directed. | 7 | 2 | Each |
|---|
| 8 | 8 | M & L for GI tubing 40mm (Light grade) and laid in trenches under road or fixed to wall/ Ploe with MS Clamp as in mechnical protection of UG cable complete all as specified and directed.\n | 8 | 12 | RM |
|---|
| 9 | 9 | M & L for GI tubing 80mm (Light grade) and laid in trenches under road as in mechnical protection of UG cable complete all as specified and directed. | 9 | 12 | RM |
|---|
| 10 | 10 | Supply and fixing of street light fitting 80 watt LED with lens, compact street light fitting with pressure diecast aluminium housing IP 66 protection with high power LED as power source complete incl provn of PVC insulated unsheathed aluminium conductor twin core cable 2.5 Sqmm, for connection from pole box to street light fitting complete all as specified and directed .\n | 10 | 2 | Each |
|---|
| 11 | 11 | Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 m in depth in a hard/dense soil for laying underground cables/ errection of steel tubular poles / stay pit etc complete all as specified and directed. | 11 | 114 | Cum |
|---|
| 12 | 12 | Excavation in trenches not exc 1.5 mtr wide and exc 1.5 m upto 3 mtr in depth in hard/dense soil for fixing of steel tubular pole/stay pit etc. complete all as specified and directed. | 12 | 1 | Cum |
|---|
| 13 | 13 | M&L for sand cushioning of the UG cable with screened unwashed river sand and punning for cushioning to cable complete all as specified and directed. | 13 | 33 | CUM |
|---|
| 14 | 14 | M&L for laying dry bricks old size with subclass 'B' made of burnt clay best quality locally available with permissible tolerance, laid straight trench for protection of cable complete all as specified and directed. | 14 | 3.6 | Per 1000 Nos. |
|---|
| 15 | 15 | M&L for cement concrete (1:4:8) type D2 using 40 mm graded stone aggregate for poles foundation complete all as specified and directed. | 15 | 4 | Cum |
|---|
| 16 | 16 | M&L for cement concrete (1:3:6) type C1 using 20 mm graded stone aggegate for pole coping and stay filling including form work and finishing to all exposed surfaces by using extra cement complete all as specified and directed. | 16 | 2.5 | Cum |
|---|
| 17 | 17 | Returning, filling in incl spreading,levelling watering and well ramming in layer n exc 25 cm thick each layer in soilcomplete all as specified and directed. | 17 | 64 | Cum |
|---|
| 18 | 18 | Removing excavated surplus material to a distance n.exc 50 m and depostimg where directed at a level n exc. 1.5 m above the starting point in any type of soil complete all as specified and directed . | 18 | 50 | Cum |
|---|
| 19 | 19 | Supply, Installation, testing and commissioning of LT Panel, outdoor type, double door, floor mounted, cubical type, factory fabricated made out of 3.15 mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof duly powder coated with naming/numbering of each item complete in all respects, suitable for 3 phase, 415V , 50 Hz Ac supply with aluminium bus bar 100 Amps 4 pole all as specified complete with the following :-\n(a) MCCB 63 Amps 4 pole with adjustable thermal and fixed magnetic settings - 01 No (as incomer)\n(b) Change over switich 4 pole 63 Amps -01No\n(c) MCCB 63 Amps 4 pole with adjustable thermal and fixed magnetic settings - 01 No (as Outgoing)\n(d) Star Delta starter for fully automatic operation with overload protection, current sensing type, single phase preventor suitable for 5 HP Pump - 02 Nos\n(e) MCB TPN of capacity 32 Amps(as Outgoing) -02 Nos\n(f) MCB SPN (As outgoing) -02 Nos\n(g) Phase indicator lamp - 01 set of three\n(h) Digital volt meter (0- 500 V) - 01 No\n(j) Digital Amps meter with suitable size CT's - 01 Set\n | 19 | 1 | Each |
|---|
| 20 | 20 | M&L for Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron strip of size 32 x 6 mm earth continuity coductor by means of bolts, nuts, check nuts and washers of galvanised iron or steel ,GI earth strip protected by GI medium grade pipe 40 mm dia all as shown in electrical plate No. 3 ,connected to earthing test point complete all as specified or indicated including testing on completion or any other equipment with provision of GI pipe light grade etc all as specified and directed including necessary excavation and earth work in hard/dense soil, returning filling, disposal of surplus soil up to 50 M, provision of concrete pit in PCC (1:2:4) type B1 using 20 mm graded stone aggregate with 40 mm thick cover of RCC 1:2:4 using 20 mm graded stone aggregate, reinforced with XPM (weight not less than 4 kg/sqm) and frame of angle iron 40x40x6 mm with 6 mm dia bar handle made to shape duly exposed surface painted with 2 coats of synthetic enamal paint over a coat of primer, necessasry form work, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 meter long placed on top edge of earth plate, common salt and charcoal filling, test point made out of bronze/ gun metal with fixing arrangement, funnel, wire mesh etc. complete all as specified and directed.\nNote: Earth continuity conductor beyond 7.5 mtr shall be mearured and paid separately. | 20 | 10 | Each |
|---|
| 21 | 21 | Supply, installation, testing and commissioning of silent type diesel engine driven generating set of capacity 30 KVA, 415 volts, 3 phase, 0.8 power factor at NTP, mounted on common base platform with flexible coupling, 1500 RPM with AMF Panel alongwith sound proof enclosure(accoustic enclosure) designed for reducing the sound level to 75 DB upto 1 mtr (Avg) IS-8528 part 10 as per approved CPCB norms and as per GSR 371(E) and 17.05.2002 with silencer pipe protected with asbestos rope independently supported from engine to outside of power house upto 1.0 mtr, AVM pads, foundation as per manufacturer's design, battery start with suitable cables for connecting from DG Set to panel board. DG Set shall include the following:-\n\n\n | 21 | 2 | Each |
|---|
| 22 | 21.1 | (A) PRIME MOVER : Vertical diesel engine of capacity not less than 40 BHP, air cooled closed circuit as per BS-649 or IS- 10002 direct injection type turbo charged alongwith oil heater to work in cold climate(Minus Temperatures). The DG Set shall be capable of running 24 Hrs continuously with 10% overloading for one hour in every 12 hours as per BS-5514/ BS-649. Engine shall be equipped with all standard fittings as per manufacturer's recommendations and mounted on common base frame with following fittings:-\n | 22 | | |
|---|
| 23 | 21.2 | (a) Ignition key and starting with push button switch.\n(b) Safety control (trip) for the following:-\n (i) Low lubricating oil pressure.\n (ii) Over speed.\n(c) 12 Volt starting equipment comprising of the following :-\n (i) 01 No 12 Volt 65 AH Battery Make : Exide/Amaron/TATA Green\n (ii) Battery charging alternator with inbuilt regulator .\n (iii) Self starter of suitable capacity.\n (iv) Battery leads (copper cable ) of suitable size with brass thimbles and terminals.\n (v) Suitable capacity inependent Battery for oil heater.\n\n | 23 | | |
|---|
| 24 | 21.3 | (B) ALTERNATOR : Alternator rating 30 KVA, 3 phase, 50 cycles, 415 volts, 4 wire supply at NTP 0.8 power factor running @ 1500 RPM self excited, self regulated mounted on common base frame, mounted on a permanent foundation screen protected with self excited ? Brushless type, Screen protected, Revolving field, alternator conforming to IS/IEC 60034-1n to be coupled with above engine through flexible coupling, the alternator shall be conforming to BS-2613 or IS-4722. | 24 | | |
|---|
| 25 | 21.4 | (C) CONTROL PANEL: Alternator control inbuilt panel suitable mounted as per manufacturer design, cubical type with inner copper wiring for 30 KVA alternator , 415 volts, 3 phase , 4 wire, 50 cycles fabricated out of 2 mm thick MS sheet, powder coated including following accessories:-\n(a) Multifunction electronic meter which displays AC current/ voltage/Water temperature/Oil pressure/ frequency/ power factor/ Kilo watt/ Kilo watt Hour (with required CTs for unbalanced load)\n(b) Moulded case circuit breaker - 1 No for incoming as recommended by manufacturer\n(c) Set of copper bus bar of suitable capacity.\n(d) Set of indicator lamps -1 set\n(e) Electrically operated alarm system alongwith following protections\n (i) DG Set overload\n (ii) Over current trip\n (iii) Low lubricant oil pressure | 25 | | |
|---|
| 26 | 21.5 | (D) OTHER FITTINGS : \n(a) Battery charger : Battery charger having electric circuit consisting of triodes rectifiers, capacitors and resistance etc. The battery charger should be able to charge the battery at all the time whenever electric supply given to battery charger through contrl panel or electric power point.\n(b) Fuel tank : Inbuilt fuel tank of suitable capacity as per manufacturer's instruction capable to store fuel for 12 hour running of DG set with oil pipes, including oil level indicating gauge, drain and air vent plug etc.\nNotes: \n1. Complete DG Set shall be supplied by any of the following:\n Kirloskar/ Greaves/ Cummins\n2. Precommissioning test shall be carried out by rep of Accepting Officer . All Testing arrangement including POL , load shall be made by the contractor.\n3. DG Set shall be mounted on PCC platform as per manufacturer recommendations .\n4.The DG set shall be supplied duly assembled by the authorized OEM/ GOEM.\n5. Contractor will produce test certificate of engine and the alternator from manufactures.\n6. The cost of above provisions shall be deemed to be included in quoted rate of this item. | 26 | | |
|---|
| 27 | 22 | Supplying, laying, jointing and testing cable XLPE insulated IS 7098 (Part-I)-1988 marked, screened, PVC sheathed, armoured electric power cable (heavy duty) with aluminium conductor for working voltage upto and including 1100 volts, cross sectional area of cable 25 sq mm, 4 core laid in trenches/fixed on pole/wall/passed through pipe complete all as specified and directed . | 27 | 100 | RM |
|---|
| 28 | 23 | Supplying, laying, jointing and testing cable XLPE insulated IS 7098 (Part-I)-1988 marked, screened, PVC sheathed, armoured electric power cable (heavy duty) with aluminum conductor for working voltage upto and including 1100 Volts, cross sectional area of cable 95 sq mm 3.5 core laid in trenches/fixed on pole/wall / passed through pipe complete all as specified and directed by Engineer-in-Charge. | 28 | 140 | RM |
|---|
| 29 | 24 | Supplying, laying, jointing and testing cable XLPE insulated IS 7098 (Part-I)-1988 marked, screened, PVC sheathed, armoured electric power cable (heavy duty) with aluminum conductor for working voltage upto and including 1100 Volts, cross sectional area of cable 70 sq mm 3.5 core laid in trenches/fixed on pole/wall / passed through pipe complete all as specified and directed by Engineer-in-Charge. | 29 | 55 | RM |
|---|
| 30 | 25 | Supplying, laying, jointing and testing in replacement XLPE insulated IS 7098 (Part-I)-1988 marked, screened, PVC sheathed, armoured electric power cable (heavy duty) with aluminium conductor for working voltage upto and including 1100 volts, cross sectional area of cable 50 sqmm 3.5 core laid in trenches/fixed on pole/wall/passed through pipe complete all as specified and directed. | 30 | 600 | RM |
|---|
| 31 | 26 | Supplying, laying, jointing and testing in replacement XLPE insulated IS 7098 (Part-I)-1988 marked, screened, PVC sheathed, armoured electric power cable (heavy duty) with aluminium conductor for working voltage upto and including 1100 volts, cross sectional area of cable 6 sqmm 2 core laid in trenches/fixed on pole/wall/passed through pipe complete all as specified and directed. | 31 | 35 | RM |
|---|
| 32 | 27 | Net Contract Sum will be after deducting Sch Of Credit of Rs. 7940.00 | 133 | | |
|---|