Railways Government Departments Closing in 0 days TDR #24141012

Fully Automatic Biochemistry Analyser

Issued by Government Departments · , Kerala
Tender Value
Ref. Documents
Estimated cost
Bid Submission
16 Apr 2020
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
→ Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Supply Of , Fully Automatic Biochemistry Analyser Technical Specification Of Fully Automatic Bio-Chemistry Analyser: 1. It Should Be New, Automated Random Access Clinical Chemistry Analyzer For Routine Chemistries And Immunochemistry. 2. Minimum Throughput Of 350 Tests/Hour Tests With Ise. The Photometric Range Should Be From 300 To 750 Nm. 3. Should Have Separate Reagent Arms To Dispense Each Of The Two Reagents Whenever Applicable. 4. Should Have Separate Stirrers For The Reagents And Sample Mixing In The Reaction Cuvettes. 5. The Analyzer Should Be Able To Perform More Than 10 Stat Samples. 6. It Should Have Permanent Non-Disposable Reaction Cuvettes. 7. It Should Have Onboard Washing For The Reaction Cuvettes. 8. It Should Have The Capacity To Perform Multi Level Q.C Daily. 9. Equipment Should Have Ce/Us Fda%U2019s Certification If Similar Standards Are Not Available In Bureau Of Indian Standards Manual. 10. It Should Have Pre, Post And Auto Dilution Of Samples For Out Of Range Sample. 11. It Should Have Halogen Lamp As Light Source. 12. Minimum 800 Samples Cups Should Be Provided With Equipment. 13. The Reaction Cuvette Must Be Reusable And Durable. 14. D.I Water Plant For The Washing Of The Q.S Should Be Provided. Compatible On Line Ups Should Be Provided. 15. Minimum 10,000 Result Storage Capacity Should Be Available 16. On Board Cuvette Washing And Drying Facility Should Be Available 17. At Least Creatinine, Urea, Uric Acid, Albumin, Sgot, Sgpt, Alkaline Phosphates, Billirubin-Total & Direct Calibrator 5Ml -4 No:S And Quality Control 5Ml -5 No:S Each For Normal And Abnormal Should Be Supplied With The Equipment. 18. Print Out Report And Full Patient Demographic Should Be Available. 19. More Than 45 Reagent Position Should Be Available. 20. Equipments Should Be Supplied With Compatible Desktop Computer With Preloaded Operating System With Flat Screen Monitor. 21. Laser Printer Should Be Provided. General Specification Of Fully Automatic Bio-Chemistry Analyser 1. Offer Should Include First 3 Years Warranty. 2. Offer Should Quote Separately For 4 Years Comprehensive Annual Maintenance Contract After The Warranty Period. These Charges Shall Include All Costs Of Personal And Spares. Any Exception To Inclusion Like Consumables Should Be Specifically Mentioned In The Offer With Their Costs During The Camc Period. Camc Will Be Necessarily Included Minimum For 4 Preventive Visits And Any Number Of Breakdown Calls. 3. Details Of The Previous Suppliers To 3 Other Railway Hospitals/Government Hospitals Should Be Provided. 4. Downtime In Case Of Breakdown Should Be 24 Hours Or Less Failing Which Standby Facilities Should Be Provided. Any Delay After 24 Hours Without Providing Standby Facility Will Be Penalizing Rs 1,000/- Per Day Shall Be Deducted From Camc Charges. 5. Inter-Se Position Of Offers Will Be Determined Based On The Sum Of Cost Of The Equipment, The Cost Towards Camc For 4 Years Following Free Comprehensive Warranty For 3 Years. The Above Specifications Are Minimum Standards Required By Us And Anything Better Would Be Acceptable.

BOQ

0 1 2 3 4 5 6 7 8 9
0 S.No. PL Code\r(Group) Item Type\rGST(Y/N) Stock /\rNonStock Ordering Consider\rFor Eval Approving\rAgency Inspection\rAgency Currency\rAllowed Estimated\rRate
1 8240NXX Goods (Y) Non Stock --- Yes CONSIGNEE INR

AI Tender Summary

OUR REF NO 24141012
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 16-04-2020
Authority
Authority Name Southern Railway
Work Description Supply Of , Fully Automatic Biochemistry Analyser Technical Specification Of Fully Automatic Bio-Chemistry Analyser: 1. It Should Be New, Automated Random Access Clinical Chemistry Analyzer For Routine Chemistries And Immunochemistry. 2. Minimum Throughput Of 350 Tests/Hour Tests With Ise. The Photometric Range Should Be From 300 To 750 Nm. 3. Should Have Separate Reagent Arms To Dispense Each Of The Two Reagents Whenever Applicable. 4. Should Have Separate Stirrers For The Reagents And Sample Mixing In The Reaction Cuvettes. 5. The Analyzer Should Be Able To Perform More Than 10 Stat Samples. 6. It Should Have Permanent Non-Disposable Reaction Cuvettes. 7. It Should Have Onboard Washing For The Reaction Cuvettes. 8. It Should Have The Capacity To Perform Multi Level Q.C Daily. 9. Equipment Should Have Ce/Us Fda%U2019s Certification If Similar Standards Are Not Available In Bureau Of Indian Standards Manual. 10. It Should Have Pre, Post And Auto Dilution Of Samples For Out Of Range Sample. 11. It Should Have Halogen Lamp As Light Source. 12. Minimum 800 Samples Cups Should Be Provided With Equipment. 13. The Reaction Cuvette Must Be Reusable And Durable. 14. D.I Water Plant For The Washing Of The Q.S Should Be Provided. Compatible On Line Ups Should Be Provided. 15. Minimum 10,000 Result Storage Capacity Should Be Available 16. On Board Cuvette Washing And Drying Facility Should Be Available 17. At Least Creatinine, Urea, Uric Acid, Albumin, Sgot, Sgpt, Alkaline Phosphates, Billirubin-Total & Direct Calibrator 5Ml -4 No:S And Quality Control 5Ml -5 No:S Each For Normal And Abnormal Should Be Supplied With The Equipment. 18. Print Out Report And Full Patient Demographic Should Be Available. 19. More Than 45 Reagent Position Should Be Available. 20. Equipments Should Be Supplied With Compatible Desktop Computer With Preloaded Operating System With Flat Screen Monitor. 21. Laser Printer Should Be Provided. General Specification Of Fully Automatic Bio-Chemistry Analyser 1. Offer Should Include First 3 Years Warranty. 2. Offer Should Quote Separately For 4 Years Comprehensive Annual Maintenance Contract After The Warranty Period. These Charges Shall Include All Costs Of Personal And Spares. Any Exception To Inclusion Like Consumables Should Be Specifically Mentioned In The Offer With Their Costs During The Camc Period. Camc Will Be Necessarily Included Minimum For 4 Preventive Visits And Any Number Of Breakdown Calls. 3. Details Of The Previous Suppliers To 3 Other Railway Hospitals/Government Hospitals Should Be Provided. 4. Downtime In Case Of Breakdown Should Be 24 Hours Or Less Failing Which Standby Facilities Should Be Provided. Any Delay After 24 Hours Without Providing Standby Facility Will Be Penalizing Rs 1,000/- Per Day Shall Be Deducted From Camc Charges. 5. Inter-Se Position Of Offers Will Be Determined Based On The Sum Of Cost Of The Equipment, The Cost Towards Camc For 4 Years Following Free Comprehensive Warranty For 3 Years. The Above Specifications Are Minimum Standards Required By Us And Anything Better Would Be Acceptable.
Basic Detail
Tender No 93205323
Bidding Type Tender
Location
City
State Kerala
Key Dates
Publish Date 03 Apr 2020
Submission Date 16 Apr 2020
Open Date 01 Jan 0001
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
1354226.pdf
1354234.pdf
328b0016-8fba-4cac-ae4c-0c93f36e1cf9.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Apr 03, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
Apr 16, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

1354226.pdf

pdf

1354234.pdf

pdf

328b0016-8fba-4cac-ae4c-0c93f36e1cf9.pdf

TenderDetail
Loading tenders