Supply Rate Of Electrical Items, Lucknow-Uttar Pradesh

Uttar Pradesh Rajkiya Nirman Nigam Limited has published Supply Rate Of Electrical Items. Submission Date for this Tender is 18-04-2020. Cutting Crimping and Punching Tools Tenders in Lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

24139658
Corrigendum : Supply Rate Of Electrical Items
National Competitive Bid
Indian
Uttar Pradesh
Lucknow
18-04-2020

Tender Details

Supply Rate Of Electrical Items-1 Sitc Of Prefabricated Steel Structure, Made Out Of Suitale Size & Length Of Ismb Sections, Both End Arc / Mig Welded With Suitable Size & Thickness Of Ms Plate Flange Incorporating Required Mounting Holes. The Steel Structure Using Sections Of Ismb Shall Be Suitable To Bear 25% Extra Shearing Load. The Structure Shall Be Fixed With Using High Quality Chemical Fasteners ( Wurth / Hilti / Fisher ) Of Suitable Grade & Length Or Shall Be Embeded / Welded The Same In Rcc Walls To Ensure Proper Load Bearing Requirements. The Work Shall Include All Logistics From Main Entrance Gate Of The Site Upto The Work Area ( Walking Distance Of Approx. 150 Mtr & Lifting Upto 7 Floor Height Using Man Power Via Stair Case ) , Making / Procuring Necessary Material Uplifting Arrangements / Scafoldings, Tools & Plants, Power Backup Dg Etc. Required At Site For Entire Work Execution In Stipulated Time. Cutting Required In Rcc Floors / Walls Shall Be Done With Non Vibrating Equipments / Core Cutting. All Structures Shall Be Coated With 2 Coats Of Red Oxide Primer. 2 Rcc Slab Supporting Steel Structure Sytem For Handling The Load Of Capacity 6000 Kgs In The Area Of 1500 Mm X 1500 Mm X 150 Mm Thick. The Structure Shall Be Made & Fixed With The Following Ismb / Chemical Anchor Fasteners / Chemicals / Hardwares Etc. As Per Requirement. 3 Ismb Of Size 200 Mm X 100 Mm, Length 2400 Mm - 2 Nos. 4 Ismb Of Size 200 Mm X 100 Mm, Length 1400 Mm - 1 No. 5 12 Mm Thick Flange Made Of Ms Plate Of Size 350Mm X 250Mm Incorporating 12 Nos. 20 Mm Dia. Holes Welded With Above Ismb Sections - 4 Nos. 6 Chemical Steel Anchor Fasteners 8.8 Grade Of Size 16Mm X 205Mm With Nuts & Washers Etc. - 48 Nos. 7 Injection Resin Mortar For Fastening In Cracked Concrete - As Per Requirement 8 See Through Cutting In 150Mm Thick Rcc Slab Of Size 1400Mm X 1400Mm With Non Vibrating Equipment Only, & Making Edges Clean & Good To Work - 1 Job 9 Prefabricated Trap Door Of Size 1400 Mm X 1400 Mm Made Out Of 50Mmx50mmx6mm Angle Iron For Outer Frame & Cover Door Out Of 40Mmx40mmx6mm & 5Mm Thick Hr Ms Plate Duly Supported At Required Intervals To Avoid Sags Upon Load, Providing Lifting Arrangement Etc.Complete In All Respect - 1 No. 10 Prefabricated Load Supporting Steel Structured Formwork Sytem For Lift Room Floor Slab Of Area 1800 Mm X 2000Mm To Continously Withdstand The Load Of Upto 6000 Kgs. The Structure Shall Be Made & Fixed With The Following Ismb / Chemical Anchor Fasteners / Chemicals / Hardwares Etc. As Required. 11 Ismb Of Size 250 Mm X 125 Mm, Length 1850 Mm - 1 No. 12 Ismb Of Size 150 Mm X 75 Mm, Length 2100 Mm - 4 Nos. 13 12 Mm Thick Flange Made Of Ms Plate Of Size 350Mm X 250Mm Incorporating 12 Nos. N20 Mm Dia. Holes Welded With Above Ismb Sections - 8 Nos. 14 Chemical Steel Anchor Fasteners 8.8 Grade Of Size 16Mm X 205Mm With Nuts & Washers Etc. - 96 Nos. 15 Injection Resin Mortar For Fastening In Cracked Concrete - As Per Requirement 16 Cutting In Rcc Walls & Grouting / Welding The Ismb Sections Etc. - As Required 17 Necessary Sheet Metal Deck Sheet To Cover Rcc Casting Area Of 1800Mm X 2000Mm - 1 No. 18 Prefabricated Load Supporting Steel Structured Formwork Sytem For Lift Room Floor Slab Of Area 2300 Mm X 2300Mm To Continously Withdstand The Load Of Upto 6000 Kgs. The Structure Shall Be Made & Fixed With The Following Ismb / Chemical Anchor Fasteners / Chemicals / Hardwares Etc. As Required. 19 Ismb Of Size 250 Mm X 125 Mm, Length 2700 Mm - 1 No. 20 Ismb Of Size 150 Mm X 75 Mm, Length 2950 Mm - 4 Nos. 21 12 Mm Thick Flange Made Of Ms Plate Of Size 350Mm X 250Mm Incorporating 12 Nos. N20 Mm Dia. Holes Welded With Above Ismb Sections - 8 Nos. 22 Chemical Steel Anchor Fasteners 8.8 Grade Of Size 16Mm X 205Mm With Nuts & Washers Etc. - 96 Nos. 23 Injection Resin Mortar For Fastening In Cracked Concrete - As Per Requirement 24 Cutting In Rcc Walls & Grouting / Welding The Ismb Sections Etc. - As Required 25 Necessary Sheet Metal Deck Sheet To Cover Rcc Casting Area Of 1800Mm X 2000Mm - 1 No. 26 Prefabricated Ismb Load Supporting Steel Structure On Roof Top To Pull Min. Point Load Of 6000 Kgs. The Structure Shall Be Made & Fixed With The Following Ismb / Chemical Anchor Fasteners / Chemicals / Hardwares Etc. As Per Requirement. 27 Ismb Of Size 250 Mm X 125 Mm, Length 500 Mm - 2 Nos. 28 Ismb Of Size 250 Mm X 125 Mm, Length 3000 Mm - 2 Nos. 29 12 Mm Thick Flange Made Of Ms Plate Of Size 500Mm X 325Mm Incorporating 12 Nos. N20 Mm Dia. Holes Welded With Above Ismb Sections - 6 Nos. 30 Chemical Steel Anchor Fasteners 8.8 Grade Of Size 16Mm X 205Mm With Nuts & Washers Etc. - 22 Nos. 31 Injection Resin Mortar For Fastening In Cracked Concrete - As Per Requirement 32 Forged D-Shakle Of 9000Kg Loading Capacity - 1 No. 33 8 Mm Forged Pulling Chain ( To Be Wraped In Multifold ) - 10 Mtr. 34 Chain Locking Clamps - 4 Nos. 35 Sitc Of Prefabricated Steel Structure, Made Out Of Suitale Size & Length Of Ismb Sections, Both End Arc / Mig Welded With Suitable Size & Thickness Of Ms Plate Flange Incorporating Required Mounting Holes. The Steel Structure Using Sections Of Ismb Shall Be Suitable To Bear 25% Extra Shearing Load. The Structure Shall Be Fixed With Using High Quality Chemical Fasteners ( Wurth / Hilti / Fisher ) Of Suitable Grade & Length Or Shall Be Embeded / Welded The Same In Rcc Walls To Ensure Proper Load Bearing Requirements. The Work Shall Include All Logistics From Main Entrance Gate Of The Site Upto The Work Area ( Walking Distance Of Approx. 150 Mtr & Lifting Upto 7 Floor Height Using Man Power Via Stair Case ) , Making / Procuring Necessary Material Uplifting Arrangements / Scafoldings, Tools & Plants, Power Backup Dg Etc. Required At Site For Entire Work Execution In Stipulated Time. Cutting Required In Rcc Floors / Walls Shall Be Done With Non Vibrating Equipments / Core Cutting. All Structures Shall Be Coated With 2 Coats Of Red Oxide Primer. 36 Ismb Of Size 250 Mm X 125 Mm Of Both End Welded With 12 Mm Thick Flange Made Of Ms Plate Of Size 500Mm X 325Mm Incorporating 12 Nos. 20 Mm Dia. Holes Fixed With Chemical Steel Anchor Fasteners 8.8 Grade Of Size 16Mm X 205Mm With Nuts & Washers Etc. 37 Ismb Of Size 200 Mm X 100 Mm Of Both End Welded With 12 Mm Thick Flange Made Of Ms Plate Of Size 500Mm X 325Mm Incorporating 12 Nos. 20 Mm Dia. Holes Chemical Steel Anchor Fasteners 8.8 Grade Of Size 16Mm X 205Mm With Nuts & Washers Etc. 38 Pumps & Equipments 39 Providing, Fixing And Testing Of Packaged Type Skid Mounted Hydro Pneumatic System 40 ( I ) Sitc Of Pre-Engineered, Factory Fabricated, Assembled & Tested, Fully Integrated, Skid Mounted, Highly Efficient Pump, Motors, Complete & Ready-To-Connect Packaged Hydro Pneumatic System. The System Shall Be Complete With Vertical Multi Stage Centrifugal Pumps Connected In Parallel, High Efficiency Motors, Intelligent Multi-Pump Controller, The Controller Shall Be Mounted In A Control Cabinet With An Enclosure Of Suitable Rating, Hot Dipped Galvanised Suction And Delivery Manifolds, Isolation Ball Valves On Suction And Discharge Of Each Pump, Non Return Valve On Discharge Side Of Each Pump, Hot Dip Galvanised Common Base Frame, And Diaphragm Pressure Vessel. 41 ( Ii ) The Pump Shall Have Cast Iron Head And Base, Ss304 Impeller, Ss304 Casing, And Cast Iron Motor Stool 42 ( Iii ) The Motor Shall Be Of High Efficiency , Insulation Class F, Enclosure Class Ip55, Capable Of Operation At 3 Phase, 50 Hz, 380-415 V, 43 ( Iv ) Pressure Vessel Of Non Corrosive Frp Composite Construction Lined With Nsf And / Or Fda Listed Material, Like High Density Polyethylene With Fully Replaceable Polyurethane. Air Cell Burst Pressure Of Minimum Of 5 Times The Vessel Operating Pressure And Cycle Tested For 2, 50, 000 Cycles. 44 ( V ) Control Panel To Be Of Enclosure Class Ip42, Cyclic Operation Of Pumps. Pump Working Sequence Should Change After Every Operation. Contactor Overload Relays , Healthy Supply Should Be Provided In The Panel Along With The Ammeter & Voltmeter. 45 ( Vi ) Pressure Tank Capacity: ( As Per Manufacturer Recommendation ) Bladders Shall Be Suitable For Sufficient Elasticity To Permit Full Expansion Inside The Tank To Ensure Better Performance And Longer Working Life. 46 ( Vii ) Pressure Switches And Having Maximum Pressure And Differential Scale Should Confirming Bs-6134 Standards And Ip55 Protection Class. 47 ( Viii ) Ball Valves To Be Used Should Nrvs To Be Used Should Be With Springs And O-Ring Arrangement. 48 ( Ix ) Pressure Switch ( 0-10 / 16 / 25Bar, Based On System Design Pressure ) 49 ( X ) Pressurge Gauge - 0-16 Bar 50 ( Xi ) Suction & Delivery Manifolds - Hot Dip Galvansied Iron 51 ( Xii ) One Non-Return Valve And Isolating Valves For Each Pump Is Provided In Delivery Side. 52 ( Xiii ) Provision For Fully Automatic Operation 53 ( Xiv ) Min. Pressure 1.5 Kgs, Max. Pressure 6.5 Kgs. 54 ( Xiii ) Dry Run Protection To Be Provided. 55 Complete Set System To Be Mounted On A Common Base Frame And Shall Follow Following Duty. 56 Hydro-Pneumatic Pump ( Kishor / Wpil / Wilo Make ) 57 Quantity - 1 Set In All Of Approx. 3Hp ( 2 Working + 1 Standy ) 58 Moc - Ss 304 59 Discharge - 12000 Lph 60 Head -35 M 61 Air Vessel - 100 L 62 65 Mm Motorised Valve With Solid State Controller, Float Switch For Automatic Filling Of 2 X 20000 Ltr Storage Tank ( Belino / Auma / Ivc / Equivalent ) 63 Dewatering / Mud Pump ( Kishor / Wpil / Wilo / Ksb / Crompton / Kirloskar ) N 64 Supply, Installation, Testing And Commissioning Of Continuous Duty Submersible, Centrifugal Non-Clogging Transfer Pump Complete With 1 Phase Motor With All Necessary Protection, Mechanical Seal, Starter Panel With Automation Etc. Complete With All Accessories Including Float Type Level Controllers, Delivery Pipe Of 32 Mm Dia Upto 3 Mtr Deliver With All Required Accessories / Manifolds. 65 Flow Rate : 12000 Lph 66 Head : 12 Mtr 67 Solid Handling : 32 Mm 68 Moc : Ci Body; Ci Impeller & Shaft 69 Ro Plant For Drinking Water ( Ion Exchange / Pentair / Aquaguard / Venza / Kent ) 70 Supply, Installation, Testing And Commissioning Of R.O. Plant Of Suitable Capacity For Filling 4000 Ltr. Potable Water Storage Tank ( Complete System To Be Compact Type, Skid-Mounted, As Per Following Parameters And Consisting Of ( But Not Limited To ) The Following Main Components:- 71 ( I ) Inlet Quantity : As Per Detailing 72 ( Ii ) Output Quantity : 1000 Lph 73 ( Iii ) Inlet Tds : 500 Ppm 74 ( Iv ) Outlet Tds : 50 Ppm 75 ( V ) Inlet Hardness : 250 Ppm 76 ( Vi ) Outlet Hardness : 50 Ppm 77 Raw Water Pumps Of Horizontal, Centrifugal Type Of Approx. 2 Hp Capacity. The Pump Construction Shall Be Of Ss-304 & Impeller Shall Be Also Ss-304. The Motor Shall Be Tefc Suitable For A Supply Of 415V / 3-Phase / 50Hz Supply. The Pump Shall Be Supplied Complete With Base Channel Coupling Foundations, Bolts, Pressure Gauge At Inlet And Outlet Of Each Pump. - 01 Set. 78 Special Antiscalant Dosing System Consisting Of One Hdpe Tank Of 100 Litre Capacity With A Positive Displacement Diaphragm Dosing Pump Having Variable Flowrate Of 0-8 Lph. The Motor Shall Be Suitable For Operation At 240V / Single Phase / 50Hz Supply. The Pump Shall Be Supplied Complete With Necessary Polypropylene Piping, Valves, Strainers & Injection Fittings. 79 Micron Cartridge Filter Suitable To Achieve Particle Filtration Of Less Than 5 Microns. The Unit Shall Be Supplied Complete With Inlet And Outlet Branches Removal Cap For Replacement Of Element, Inlet And Outlet Pressure Indicators. 80 R.O High Pressure Feed Pumps Of Vertical, Multistage Centrifugal Type Of Approx. 3 Hp Capacity. The Pump Construction Shall Be Of Ss-304 & Impeller Shall Be Also Ss-304. The Motor Shall Be Of Tefc Suitable For A Supply Of 415V / 3 Phase / 50 Hz Supply. The Pump Shall Be Supplied Complete With Base Channel Coupling Foundation, Bolt, Pressure Gauge At Inlet And Outlet Of Each Pump. 81 ( I ) Total Net Treated Water Output Of System = 1000 Lph 82 ( Ii ) System Recovery = 50 - 60 % 83 ( Iii ) Filtration Area Per Membrane = 85 Sq.Ft. 84 Centralised Control Panel Board Made Out Of Crca Sheet Min.1.6 Mm Thick Having Main Contactors For All Pumps ( Listed Above ) Including Spp, 3 Phase Thermal Overload Relay. The Control Panel For Monitoring And Control Of P.O. System Shall Include All Required Signal Lamps, Hrc Fuses, All Control And Power Cabling Along With Double Earthing Between The Panel Shall Be Included In The Scope Of Supply Of The Contractor. 85 Special Anti-Scalant Dosing Pump 86 Pressure Switches To Control Pressure 87 First Fill Of All Chemicals And Lubricants To Commission And Operate The Plants. 88 All Interconnecting Piping Work With Non Return / Pneumatic Valves:- 89 Complete Thermal Insulated Stainless Steel Treated Water Storage Tank Of Capacity 4000 Litres Including All Inlet / Outlet Connections, Accessories, Valves, Etc. 90 Activated Carbon Filter ( Automatic Type For Online Installation Before The Micron Filters ) . The Material Of Construction Shall Be Composite Frp. The Unit Shall Be Supplied Complete With Multi-Port Valves, Inlet And Outlet Branches Removal Caps Of Replacement Of Elements Inlet And Outlet Pressure Indicators. - 1 Set 91 Supply Of Factory Fabricated & Wired, Metal Clad Dust & Vermin Proof, Floor Mounting Type Electrical Control Panel Fabricated Out Of 2 Mm Thick Crca Sheet Steel & Ms Channel Base Of 100 X 50 X 6 Mm. The Panel Shall Meet Ip 54 Degree Of Protection Using Suitable Neuprene Gaskets Where Ever Required. The Instrument Chamber Shall Be Seperate & Shall Comprise Of Flush Type Digital Metering System With Selector Switches For Phase To Phase & Phase To Neutral Voltage, Line Current With Off With Cts For Different Readings, Backup Protection Mcbs, Phase Indicating Led Lights Etc. The Panel Board Shall Have Suitable Capacity Of Electrolytic & Electrical Grade Aluminium Bus Bars Insulated With Pvc Heat Shrink Sleeves & Mounted On Non Hygroscopic Smc / Dmc Supports. No Cable Shall Be Terminated Directly On To The Switchgear Terminal For Which Necessary Arrangement Should Be Made With Bus Bar Extensions / Connectors Including Hardwares For Cable Jointing. The Panel Board Shall Be Compartmentalized & Shall Have Frp Sheet Protection Where Ever Bus Bar Crosses From One Compartment To Other. The Panel Should Be Scada Compatible So That It Can Be Communicated Through Scada In Future Whenever Required. All The Acbs & Mccbs Shall Be Compatible To Provide On / Off / Trip Status On Ethernet / Modbus. All Major Switchgears Shall Be Of ( L&T / Schneider / Siemens ) , Metering Instruments Shall Be Of ( L&T / Ae / Optron / Procom / Reputed ) . 92 Main Lt Panel 93 Incoming 94 2500 A 4P 50 Ka Edo Acb With O / L, S / C, E / F & Other Necessary Protections - 2 Sets 95 1600 A 4P 50 Ka Edo Acb With O / L, S / C, E / F & Other Necessary Protections - 1 Set 96 Protection As Per Ansi Code No. 50, 50N, 51, 51N, 27, 32, 49, 59, 86, 95 97 Bus - Coupler 98 2500 A 4P 50 Ka Edo Acb With O / L, S / C, E / F & Other Necessary Protections - 1 Set 99 Interlocking 100 All The Incoming & Bus Coupler Acbs Shall Be Electrically Interlocked To Achieve The Purpose As Per Site Requirements & Compatiliility With Synchronizing Panel 101 Metering 102 Multifunction Meter Cl 1.0 With Rs - 485, Ctr - / 5A, Ptr - 500V - 2 Sets 103 R, Y, B, Phase Indicating Led Lights - 3 Sets 104 Acb On / Off / Trip Status Led Indicator - 3 Sets 105 6 A Control & Backup Mcbs - 3 Sets 106 Ctr - / 5 A, Current Transformer, For Metering Instruments - 3 Sets 107 Ctr - / 5 A, Current Transformer, For Apfc Panels - 2 Sets 108 Ctr - / 5 A, Current Transformer, For Protection Relays - 3 Sets 109 Bus Bars 110 2500 A Tpn Aluminium 111 Outg0ing 112 63 A Tpn 36 Ka Mccb With Necessary Protections, Spreader Links & Rom, R, Y, B, Led Indicators Backed Up With 6A Mcbs - 6 Sets 113 100 A Tpn 36 Ka Mccb With Necessary Protections, Spreader Links & Rom, R, Y, B, Led Indicators Backed Up With 6A Mcbs, Digital Am + Ass + 100 / 5 A Cts - 3 Sets 114 125 A Tpn 36 Ka Mccb With Necessary Protections, Spreader Links & Rom, R, Y, B, Led Indicators Backed Up With 6A Mcbs, Digital Am + Ass + 150 / 5 A Cts - 5 Sets 115 200 A Tpn 36 Ka Mccb With Necessary Protections, Spreader Links & Rom, R, Y, B, Led Indicators Backed Up With 6A Mcbs, Digital Am + Ass + 200 / 5 A Cts - 2 Sets 116 250 A Tpn 36 Ka Mccb With Necessary Protections, Spreader Links & Rom, R, Y, B, Led Indicators Backed Up With 6A Mcbs, Digital Am + Ass + 250 / 5 A Cts - 4 Sets 117 400 A Tpn 36 Ka Mccb With Necessary Protections, Spreader Links & Rom, R, Y, B, Led Indicators Backed Up With 6A Mcbs, Digital Am + Ass + 400 / 5 A Cts - 6 Sets 118 500 A Tpn 36 Ka Mccb With Necessary Protections, Spreader Links & Rom, R, Y, B, Led Indicators Backed Up With 6A Mcbs, Digital Am + Ass + 500 / 5 A Cts - 2 Sets 119 630 A Tpn 36 Ka Mccb With Necessary Protections, Spreader Links & Rom, R, Y, B, Led Indicators Backed Up With 6A Mcbs, Digital Am + Ass + 600 / 5 A Cts - 2 Sets 120 800 A Tpn 50 Ka, Aluminium Bus Bar Links, R, Y, B, Led Indicators Backed Up With 6A Mcbs, Digital Am + Ass + 800 / 5 A Cts To Connect Apfc Panels - 2 Sets 121 Syncronizing Panel For 2 X 500 Kva Dg Sets 122 Incoming 123 800A Fp Edo 50Ka Acb With Microprocessor Based Release For Protection Against O / C, S / C & E / F With Shunt Trip, Under Voltage Release & Closing Coil Etc. - 2 Sets 124 Digital Metering 125 Multi Function Meter With Rs 485 Communication Port, Cts, Indicating Lights With Backup Protection Mcbs - 2 Sets 126 Bus – Bars ( Main Horizontal ) N 127 2000 A, Tpn Aluminium Bus Bars With Pvc Heat Shrink Sleeves Nand Mounted On Non Hygroscopic Smc / Dmc Supports 128 Control Instruments : 129 Plc Along With Required Modules & Software - 1 Set 130 Hmi / Annunciation Window Display - 1 Set 131 Resin Cast Cts 800 / 5A 15Va With Shorting Terminals - 2 Sets 132 Status Indicating Lights 24V Dc - 2 Sets 133 Phase Indicating Lights 230V Ac ( R, Y, B ) - 2 Sets 134 Auto / Manual Selector Switch 2P 2W - 1 Set 135 Power Switch Socket 15 A - 1 Set 136 Push Button With No / Nc Contacts ( For Start ) - 2 Sets 137 Push Button With No / Nc Contacts ( For Stop ) - 2 Sets 138 Push Button With No / Nc Contacts ( For Fault Accept ) - 2 Sets 139 Push Button With No / Nc Contacts ( For Reset ) - 2 Sets 140 Push Button With No / Nc Contacts ( For Emergency Stop ) - 2 Sets 141 On / Off Selector Switch For Battery Charger - 2 Sets 142 24 V Dc 20 A Smps Battery Charger - 2 Sets 143 Dc Vm Analog Type 30 V - 2 Sets 144 Dc Am Analog Type 20 A - 2 Sets 145 Sp Control Mcbs - 2 Sets 146 Dp Control Mcbs - 2 Sets 147 Fp Control Mcbs - 2 Sets 148 Push Buttons With Aux. Control Contacts - 2 Sets 149 Control Relays 4Co 24V Dc - 2 Sets 150 Control Relays 4Co 230V Ac - 2 Sets 151 Control Contactors 24V Dc - 2 Sets 152 Control Contactors 230V Ac - 2 Sets 153 Control Connectors - 2 Sets 154 Relay Board 24V Dc - 2 Sets 155 Power Supply 24V Dc 5A - 2 Sets 156 Hooter 24V Dc - 2 Sets 157 Cooling Fan 230V Ac - 2 Sets 158 Breaker Control Switch 25A ( Tnc ) - 2 Sets 159 Space Heater With Thermostat - 2 Sets 160 24V 20A Rectifier With Heat Sink - 2 Sets 161 Control Terminal Block 4 Sq.Mm. - 2 Sets 162 Ups - 1 Set 163 Protection Relay If Required Other Than Incorporated In Dg Controller 164 Protection Relays 165 Trip Circuit Supersion Relay ( 95 ) - 2 Sets 166 Master Trip Relay ( 86 ) - 2 Sets 167 Under Voltage Release ( 27 ) - 2 Sets 168 Over Voltage Relay ( 59 ) - 2 Sets 169 Rpr ( 32 ) - 2 Sets 170 Supply Of Factory Fabricated & Wired, Metal Clad Dust & Vermin Proof, Floor Mounting Type 300 Kvar Automatic Power Factor Correction Panel Fabricated Out Of 2 Mm Thick Crca Sheet Steel & Ms Channel Base Of 100 X 50 X 6 Mm. The Instrument Chamber Shall Be Seperate & Shall Comprise Of Flush Type Digital Metering System With Selector Switches For Phase To Phase & Phase To Neutral Voltage, Line Current With Off With Cts For Different Readings, Backup Protection Mcbs, Phase Indicating Led Lights Etc. The Panel Board Shall Have Suitable Capacity Of Electrolytic & Electrical Grade Aluminium Bus Bars Insulated With Pvc Heat Shrink Sleeves & Mounted On Non Hygroscopic Smc / Dmc Supports. No Cable Shall Be Terminated Directly On To The Switchgear Terminal For Which Necessary Arrangement Should Be Made With Bus Bar Extensions / Connectors Including Hardwares For Cable Jointing. The Panel Board Shall Have Frp / Ploycarbonate Sheet Protection Where Ever Bus Bar Crosses From One Compartment To Other. All The Mccbs Shall Have Min. Breaking Capacity Of 36 Ka & Mcb Of 10 Ka . All Major Switchgears Shall Be Of ( L&T / Schneider / Siemens ) , Metering Instruments Shall Be Of ( L&T / Ae / Optron / Procom / Reputed ) , Capacitors Shall Be Of ( L&T / Epcos / Abb ) 171 300 Kvar Panel Switchgears 172 Incoming 173 630 A Tpn 36 Ka Mccb To Provide Protection For O / L, S / C & E / F With Spreader Links & Rom - 1 Set 174 Metering 175 Digital Voltmeter 0-500 V With Vss - 1 Set 176 Digital Ammeter 0-600 A With Cts & Ass - 1 Set 177 R, Y, B, Phase Indicating Led Lights - 1 Set 178 6 A Control & Backup Mcbs - 4 Sets 179 Control & Auxiliary Devices 180 Apfc Relay With Rs - 485 - 1 Set 181 Control Contactor 3No + 3Nc - 2 Sets 182 Hooter System - 1 Set 183 Cooling Fans With Thermostat & Timers - 4 Sets 184 Bus Bars 185 800 A Tpn Aluminium - 1 Set 186 Outgoing 187 Power Factor Correction Heavy Duty Capacitor 40 Kvar 480 V With Suitable Mccb / Mcb, Ac-3 Duty Fast Acting Switching Devices / Thyristor Backed Up With 7% Detuned Reactor - 4 Sets 188 Power Factor Correction Heavy Duty Capacitor 20 Kvar 480 V With Suitable Mccb / Mcb, Ac-3 Duty Fast Acting Switching Devices / Thyristor Backed Up With 7% Detuned Reactor - 6 Sets 189 Power Factor Correction Heavy Duty Capacitor 10 Kvar 480 V With Suitable Mccb / Mcb, Ac-3 Duty Fast Acting Switching Devices / Thyristor Backed Up With 7% Detuned Reactor - 2 Sets 190 On / Off Push Buttons - 12 Sets 191 On Indicating Led Lights - 12 Sets 192 Supply Of Factory Fabricated & Wired, Metal Clad Dust & Vermin Proof, Floor Mounting Outdoor Type, Fully Automatic Street Light Feeder Pillar, Fabricated Out Of 2 Mm Thick Crca Sheet Steel & Ms Channel Base Of 75 X 40 X 5 Mm. The Instrument Chamber Shall Be Seperate & Shall Comprise Of Flush Type Digital Metering System With Selector Switches For Phase To Phase & Phase To Neutral Voltage, Line Current With Off With Cts For Different Readings, Backup Protection Mcbs, Phase Indicating Led Lights Etc. The Panel Board Shall Have Suitable Capacity Of Electrolytic & Electrical Grade Aluminium Bus Bars Insulated With Pvc Heat Shrink Sleeves & Mounted On Non Hygroscopic Smc / Dmc Supports. No Cable Shall Be Terminated Directly On To The Switchgear Terminal For Which Necessary Arrangement Should Be Made With Bus Bar Extensions / Connectors Including Hardwares For Cable Jointing. The Panel Board Shall Have Frp / Ploycarbonate Sheet Protection Where Ever Bus Bar Crosses From One Compartment To Other. All The Mccbs Shall Have Min. Breaking Capacity Of 36 Ka & Mcb Of 10 Ka. All Major Switchgears Shall Be Of ( L&T / Schneider / Siemens ) , Metering Instruments Shall Be Of ( L&T / Ae / Optron / Procom / Reputed ) . 193 Incoming 194 125 A Tpn 36 Ka Mccb To Provide Protection For O / L, S / C & With Spreader Links & Rom - 1 Set 195 95 A Ac-3 Duty Power Contactor - 1 Set 196 Astronomical Time Switch - 1 Set 197 Auto / Manual Switch - 1 Set 198 Metering 199 Digital Voltmeter 0-500 V With Vss - 1 Set 200 Digital Ammeter 0-100 A With Cts & Ass - 1 Set 201 R, Y, B, Phase Indicating Led Lights - 1 Set 202 6 A Control & Backup Mcbs - 4 Sets 203 Bus Bars 204 150 A Tpn Aluminium - 1 Set 205 Outgoing 206 32 A 4P 10 Ka Mcb ( On Timer ) . - 6 Sets 207 32 A 4P 10 Ka Mcb ( Direct To Ht Room ) - 1 Set 208 20 / 25 A Tpn +G Ip65 Socket For General Maintenance - 1 Set 209 Supply Of Totally Enclosed Ht Vcb Panel, Floor Mounting Metal Clad, Indoor Type, With Electrically Operated, Manually Drawout Type, Isolation Type, 11.4 Kv 630 A Vcb ( 2 I / C + 1 B / C + 2 O / G ) , Fault Level Of 18.4 Ka For 1 Sec. Comprising Of Following Instruments. ( Schneider / L&T / C&S Make ) 210 Incoming Feeder : 11.4 Kv 630 A Vcb, Fault Level Of 18.4 Ka For 1 Sec. With Aux. Contactors 211 Metering & Protection 212 Ct - 11 Kv Dual Core 200 / 5A Core Cl1:1.0, 10Va, Core Cl2:5P10 10 Va- 3 Nos. 213 Pt - 11 Kv / 110V Single Ph., With Fuse, Core-1, Class-.05, 100 Va Dual Core 200 / 5A Core Cl:1.0, 10Va - 3 Nos 214 Protective Relays : 215 Idmt - 1 No. 216 Master Trip Relay - 1 No. 217 Anti Pumping System - 1 No. 218 Digital Ammeter With Ass Cl.1 - 1 No. 219 Digital Voltmeter With Vss Cl.1 - 1 No. 220 Indications With Backup Protection Mcbs For Ryb, On / Off / Trip, Spring Charge Healthy, Trip Circuit Healthy, Test / Service - 10 Sets 221 Others : Tnc - 1 No., L / R Sw. - 1 No., P / B For Tcs Check - 1 No., E / Pb - 1 No., Led Indicator- 1 No., 3 Pin Socket-1No., Toggle Sw. - 1 No., Door Sw. - 1 No., Space Heater With Thermostat - 1 Set, Control - 1 Lot 222 Bus Coupler : 11.4 Kv 630 A Vcb, Fault Level Of 18.4 Ka For 1 Sec. With Aux. Contactors - 1 No 223 Protective Relays : 224 Anti Pumping System - 1 No. 225 Indications With Backup Protection Mcbs For On / Off / Trip, Spring Charge Healthy, Trip Circuit Healthy, Test / Service - 7 Sets 226 Others : Tnc - 1 No., L / R Sw. - 1 No., P / B For Tcs Check - 1 No., E / Pb - 1 No., Led Indicator- 1 No., 3 Pin Socket-1No., Toggle Sw. - 1 No., Door Sw. - 1 No., Space Heater With Thermostat - 1 Set, Control - 1 Lot 227 Outgoing Feeder : 11.4 Kv 630 A Vcb, Fault Level Of 18.4 Ka For 1 Sec. With Aux. Contactors 228 Metering & Protection 229 Ct - 11 Kv Dual Core 100 / 5A Core Cl1:1.0, 10Va, Core Cl2:5P10 10 Va- 3 Nos. 230 Protective Relays : 231 Idmt - 1 No. 232 Master Trip Relay - 1 No. 233 Anti Pumping System - 1 No. 234 Aux. Relay - 2 Nos. 235 Digital Ammeter With Ass Cl.1 - 1 No. 236 Indications With Backup Protection Mcbs Foron / Off / Trip, Spring Charge Healthy, Trip Circuit Healthy, Test / Service - 7 Sets 237 Others : Tnc - 1 No., L / R Sw. - 1 No., P / B For Tcs Check - 1 No., E / Pb - 1 No., Led Indicator- 1 No., 3 Pin Socket-1No., Toggle Sw. - 1 No., Door Sw. - 1 No., Space Heater With Thermostat - 1 Set, Control - 1 Lot 238 Annunciator Window 8 Module - 1 No. 239 Decorative Lighting Poles With Single Arm ( Luxture / Crompton / Bajaj Make ) 240 Length - 2 Mtr. 241 Length - 5 Mtr. 242 Length - 6 Mtr. 243 Length - 7 Mtr. 244 Length - 9 Mtr. 245 Gi Octagonal Pole Including All Accessories ( Philips / Crompton / Bajaj / Valmont Make ) 246 Length - 2 Mtr. 247 Length - 5 Mtr. 248 Length - 6 Mtr. 249 Length - 7 Mtr. 250 Length - 9 Mtr. 251 Gi Arms For Octagonal Pole ( Philips / Crompton / Bajaj / Valmont Make ) 252 Single Arm 253 Double Arm 254 Pvc Junction Box Of Size 40 Mm 3 & 4 Way 255 Pvc Ferrule Of Size 2.5 256 Pvc Cable Tie 257 Length - 150 Mm 258 Length - 300 Mm 259 Ms U Clamp For Cable Tray Made Of 35X35x5 Mm, 2 X ( 1.0 Mtr X 0.470 Mtr ) 260 Dwc Pipe Of 120 Mm Dia ( Make - Rex / Durapalst / Duraline / Opticome )

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 06-Apr-2020 Change Few Dates of Supply Rate of Electrical Items E- Proc. Date 18-04-2020

Key Value

Document Fees
INR 5900 /-
EMD
INR 1.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: SUPPLY RATE OF ELCTRICAL ITEMS
Sl. No. Item Description Item Code / Make Quantity Units
1 1 SITC of prefabricated steel structure, made out of suitale size & length of ISMB sections, both end ARC / MIG welded with suitable size & thickness of MS plate flange incorporating required mounting holes. The steel structure using sections of ISMB shall be suitable to bear 25% extra shearing load. The structure shall be fixed with using high quality chemical fasteners (wurth/hilti/fisher) of suitable grade & length or shall be embeded / welded the same in RCC walls to ensure proper load bearing requirements. The work shall include all logistics from main entrance gate of the site upto the work area (walking distance of approx. 150 mtr & lifting upto 7 floor height using man power via stair case), making / procuring necessary material uplifting arrangements / scafoldings, tools & plants, power backup DG etc. required at site for entire work execution in stipulated time. Cutting required in RCC floors / walls shall be done with non vibrating equipments / Core Cutting. All structures shall be coated with 2 coats of red oxide primer. BI01010001010000000000000515BI0100001112
2 2 RCC Slab supporting steel structure sytem for handling the load of capacity 6000 kgs in the area of 1500 mm x 1500 mm x 150 mm thick. The structure shall be made & fixed with the following ISMB/ Chemical anchor fasteners/chemicals/hardwares etc. as per requirement. BI01010001010000000000000515BI0100001113
3 3 ISMB of size 200 mm X 100 mm, Length 2400 mm - 2 Nos. BI01010001010000000000000515BI0100001114
4 4 ISMB of size 200 mm X 100 mm, Length 1400 mm - 1 No. BI01010001010000000000000515BI0100001115
5 5 12 mm thick flange made of MS plate of size 350mm X 250mm incorporating 12 Nos. 20 mm dia. Holes welded with above ISMB sections - 4 Nos. BI01010001010000000000000515BI0100001116
6 6 Chemical steel anchor fasteners 8.8 grade of size 16mm X 205mm with nuts & washers etc. - 48 Nos. BI01010001010000000000000515BI0100001117
7 7 Injection resin mortar for fastening in cracked concrete - As per requirement BI01010001010000000000000515BI0100001118
8 8 See through cutting in 150mm thick RCC slab of size 1400mm X 1400mm with non vibrating equipment only, & making edges clean & good to work - 1 job BI01010001010000000000000515BI0100001119
9 9 Prefabricated trap door of size 1400 mm X 1400 mm made out of 50mmx50mmx6mm angle iron for outer frame & cover door out of 40mmx40mmx6mm & 5mm thick HR MS plate duly supported at required intervals to avoid sags upon load, providing lifting arrangement etc.complete in all respect - 1 No. BI01010001010000000000000515BI0100001120 1 Job
10 10 Prefabricated load supporting steel structured formwork sytem for lift room floor slab of area 1800 mm X 2000mm to continously withdstand the load of upto 6000 kgs. The structure shall be made & fixed with the following ISMB/ Chemical anchor fasteners/chemicals/hardwares etc. as required. BI01010001010000000000000515BI0100001121
11 11 ISMB of size 250 mm X 125 mm, Length 1850 mm - 1 No. BI01010001010000000000000515BI0100001122
12 12 ISMB of size 150 mm X 75 mm, Length 2100 mm - 4 Nos. BI01010001010000000000000515BI0100001123
13 13 12 mm thick flange made of MS plate of size 350mm X 250mm incorporating 12 Nos. \n20 mm dia. Holes welded with above ISMB sections - 8 Nos. BI01010001010000000000000515BI0100001124
14 14 Chemical steel anchor fasteners 8.8 grade of size 16mm X 205mm with nuts & washers etc. - 96 Nos. BI01010001010000000000000515BI0100001125
15 15 Injection resin mortar for fastening in cracked concrete - As per requirement BI01010001010000000000000515BI0100001126
16 16 Cutting in RCC walls & grouting/Welding the ISMB sections etc. - as required BI01010001010000000000000515BI0100001127
17 17 Necessary sheet metal deck sheet to cover RCC casting area of 1800mm X 2000mm - 1 No. BI01010001010000000000000515BI0100001128 2 Job
18 18 Prefabricated load supporting steel structured formwork sytem for lift room floor slab of area 2300 mm X 2300mm to continously withdstand the load of upto 6000 kgs. The structure shall be made & fixed with the following ISMB/ Chemical anchor fasteners/chemicals/hardwares etc. as required. BI01010001010000000000000515BI0100001129
19 19 ISMB of size 250 mm X 125 mm, Length 2700 mm - 1 No. BI01010001010000000000000515BI0100001130
20 20 ISMB of size 150 mm X 75 mm, Length 2950 mm - 4 Nos. BI01010001010000000000000515BI0100001131
21 21 12 mm thick flange made of MS plate of size 350mm X 250mm incorporating 12 Nos. \n20 mm dia. Holes welded with above ISMB sections - 8 Nos. BI01010001010000000000000515BI0100001132
22 22 Chemical steel anchor fasteners 8.8 grade of size 16mm X 205mm with nuts & washers etc. - 96 Nos. BI01010001010000000000000515BI0100001133
23 23 Injection resin mortar for fastening in cracked concrete - As per requirement BI01010001010000000000000515BI0100001134
24 24 Cutting in RCC walls & grouting/Welding the ISMB sections etc. - as required BI01010001010000000000000515BI0100001135
25 25 Necessary sheet metal deck sheet to cover RCC casting area of 1800mm X 2000mm - 1 No. BI01010001010000000000000515BI0100001136 1 Job
26 26 Prefabricated ISMB load supporting steel structure on roof top to pull Min. point load of 6000 kgs. The structure shall be made & fixed with the following ISMB/ Chemical anchor fasteners/chemicals/hardwares etc. as per requirement. BI01010001010000000000000515BI0100001137
27 27 ISMB of size 250 mm X 125 mm, Length 500 mm - 2 Nos. BI01010001010000000000000515BI0100001138
28 28 ISMB of size 250 mm X 125 mm, Length 3000 mm - 2 Nos. BI01010001010000000000000515BI0100001139
29 29 12 mm thick flange made of MS plate of size 500mm X 325mm incorporating 12 Nos. \n20 mm dia. Holes welded with above ISMB sections - 6 Nos. BI01010001010000000000000515BI0100001140
30 30 Chemical steel anchor fasteners 8.8 grade of size 16mm X 205mm with nuts & washers etc. - 22 Nos. BI01010001010000000000000515BI0100001141
31 31 Injection resin mortar for fastening in cracked concrete - As per requirement BI01010001010000000000000515BI0100001142
32 32 Forged D-Shakle of 9000kg loading capacity - 1 No. BI01010001010000000000000515BI0100001143
33 33 8 mm forged pulling chain (To be wraped in multifold) - 10 mtr. BI01010001010000000000000515BI0100001144
34 34 Chain locking clamps - 4 Nos. BI01010001010000000000000515BI0100001145 1 Job
35 35 SITC of prefabricated steel structure, made out of suitale size & length of ISMB sections, both end ARC / MIG welded with suitable size & thickness of MS plate flange incorporating required mounting holes. The steel structure using sections of ISMB shall be suitable to bear 25% extra shearing load. The structure shall be fixed with using high quality chemical fasteners (wurth/hilti/fisher) of suitable grade & length or shall be embeded / welded the same in RCC walls to ensure proper load bearing requirements. The work shall include all logistics from main entrance gate of the site upto the work area (walking distance of approx. 150 mtr & lifting upto 7 floor height using man power via stair case), making / procuring necessary material uplifting arrangements / scafoldings, tools & plants, power backup DG etc. required at site for entire work execution in stipulated time. Cutting required in RCC floors / walls shall be done with non vibrating equipments / Core Cutting. All structures shall be coated with 2 coats of red oxide primer. BI01010001010000000000000515BI0100001146
36 36 ISMB of size 250 mm X 125 mm of both end welded with 12 mm thick flange made of MS plate of size 500mm X 325mm incorporating 12 Nos. 20 mm dia. holes fixed with Chemical steel anchor fasteners 8.8 grade of size 16mm X 205mm with nuts & washers etc. BI01010001010000000000000515BI0100001147 10 Mtr
37 37 ISMB of size 200 mm X 100 mm of both end welded with 12 mm thick flange made of MS plate of size 500mm X 325mm incorporating 12 Nos. 20 mm dia. Holes Chemical steel anchor fasteners 8.8 grade of size 16mm X 205mm with nuts & washers etc. BI01010001010000000000000515BI0100001148 10 Mtr
38 38 PUMPS & EQUIPMENTS BI01010001010000000000000515BI0100001149
39 39 Providing, fixing and testing of packaged type skid mounted hydro pneumatic system BI01010001010000000000000515BI0100001150
40 40 (i) SITC of pre-engineered, factory fabricated, assembled & tested, fully integrated, skid mounted, highly efficient pump, motors, complete & ready-to-connect packaged hydro pneumatic system. The system shall be complete with vertical multi stage centrifugal pumps connected in parallel, high efficiency motors, intelligent multi-pump controller, the controller shall be mounted in a control cabinet with an enclosure of suitable rating, hot Dipped Galvanised suction and delivery manifolds, isolation ball valves on suction and discharge of each pump, non return valve on discharge side of each pump, hot dip galvanised common base frame, and diaphragm pressure vessel. BI01010001010000000000000515BI0100001151
41 41 (ii) The pump shall have cast iron head and base, SS304 impeller, SS304 Casing, and cast iron motor stool BI01010001010000000000000515BI0100001152
42 42 (iii) The motor shall be of high efficiency , insulation class F, enclosure class IP55, capable of operation at 3 phase, 50 Hz, 380-415 V, BI01010001010000000000000515BI0100001153
43 43 (iv) Pressure vessel of non corrosive FRP composite construction lined with NSF and/or FDA listed material, like high density polyethylene with fully replaceable polyurethane. Air cell burst pressure of minimum of 5 times the vessel operating pressure and cycle tested for 2,50,000 cycles. BI01010001010000000000000515BI0100001154
44 44 (v) Control Panel to be of enclosure class IP42, cyclic operation of pumps. Pump working sequence should change after every operation. Contactor overload relays , healthy supply should be provided in the panel along with the ammeter & voltmeter. BI01010001010000000000000515BI0100001155
45 45 (vi) Pressure tank capacity: (as per manufacturer recommendation) Bladders shall be suitable for sufficient elasticity to permit full expansion inside the tank to ensure better performance and longer working life. BI01010001010000000000000515BI0100001156
46 46 (vii) Pressure switches and having maximum pressure and differential scale should confirming BS-6134 standards and IP55 protection class. BI01010001010000000000000515BI0100001157
47 47 (viii) Ball valves to be used should NRVs to be used should be with Springs and O-Ring arrangement. BI01010001010000000000000515BI0100001158
48 48 (ix) Pressure Switch (0-10/16/25bar, based on system design pressure) BI01010001010000000000000515BI0100001159
49 49 (x)Pressurge Gauge - 0-16 bar BI01010001010000000000000515BI0100001160
50 50 (xi)Suction & Delivery Manifolds - Hot Dip Galvansied Iron BI01010001010000000000000515BI0100001161
51 51 (xii)One non-return valve and isolating valves for each pump is provided in delivery side. BI01010001010000000000000515BI0100001162
52 52 (xiii) Provision for fully automatic operation BI01010001010000000000000515BI0100001163
53 53 (xiv) Min. Pressure 1.5 Kgs, Max. Pressure 6.5 Kgs. BI01010001010000000000000515BI0100001164
54 54 (xiii) Dry Run protection to be provided. BI01010001010000000000000515BI0100001165
55 55 Complete set system to be mounted on a common base frame and shall follow following duty. BI01010001010000000000000515BI0100001166
56 56 Hydro-pneumatic Pump ( Kishor / WPIL / WILO make ) BI01010001010000000000000515BI0100001167
57 57 Quantity - 1 Set in all of Approx. 3HP (2 Working + 1 Standy) BI01010001010000000000000515BI0100001168
58 58 MOC - SS 304 BI01010001010000000000000515BI0100001169
59 59 Discharge - 12000 LPH BI01010001010000000000000515BI0100001170
60 60 Head -35 m BI01010001010000000000000515BI0100001171
61 61 Air Vessel - 100 L BI01010001010000000000000515BI0100001172
62 62 65 mm Motorised valve with solid state controller, Float Switch for automatic filling of 2 X 20000 Ltr storage tank (Belino/Auma/IVC/Equivalent) BI01010001010000000000000515BI0100001173 1 Job
63 63 Dewatering / Mud Pump ( Kishor / WPIL / WILO/ KSB/Crompton/Kirloskar )\n BI01010001010000000000000515BI0100001174
64 64 Supply, installation, testing and commissioning of continuous duty submersible, centrifugal non-clogging transfer pump complete with 1 phase motor with all necessary protection, mechanical seal, Starter panel with automation etc. complete with all accessories including float type level controllers, delivery pipe of 32 mm dia upto 3 mtr deliver with all required accessories/manifolds. BI01010001010000000000000515BI0100001175
65 65 Flow rate : 12000 LPH BI01010001010000000000000515BI0100001176
66 66 Head : 12 Mtr BI01010001010000000000000515BI0100001177
67 67 Solid Handling : 32 MM BI01010001010000000000000515BI0100001178
68 68 MOC : CI body; CI Impeller & Shaft BI01010001010000000000000515BI0100001179 3 Job
69 69 RO Plant for Drinking Water (Ion Exchange / Pentair / Aquaguard/Venza/Kent) BI01010001010000000000000515BI0100001180
70 70 Supply, installation, testing and commissioning of R.O. Plant of suitable capacity for filling 4000 Ltr. potable water storage tank (Complete system to be compact type, skid-mounted, as per following parameters and consisting of (but not limited to) the following main components:- BI01010001010000000000000515BI0100001181
71 71 (i) Inlet Quantity : As per Detailing BI01010001010000000000000515BI0100001182
72 72 (ii) Output Quantity : 1000 LPH BI01010001010000000000000515BI0100001183
73 73 (iii) Inlet TDS : 500 PPM BI01010001010000000000000515BI0100001184
74 74 (iv) Outlet TDS : 50 PPM BI01010001010000000000000515BI0100001185
75 75 (v) Inlet Hardness : 250 PPM BI01010001010000000000000515BI0100001186
76 76 (vi) Outlet Hardness : 50 PPM BI01010001010000000000000515BI0100001187
77 77 Raw Water pumps of horizontal, centrifugal type of approx. 2 hp capacity. The Pump construction shall be of SS-304 & impeller shall be also SS-304. The motor shall be TEFC suitable for a supply of 415V/3-phase/50Hz supply. The pump shall be supplied complete with base channel coupling foundations, bolts, pressure gauge at inlet and outlet of each pump. - 01 Set. BI01010001010000000000000515BI0100001188
78 78 Special Antiscalant Dosing System consisting of one HDPE tank of 100 litre capacity with a positive displacement diaphragm dosing pump having variable flowrate of 0-8 LPH. The motor shall be suitable for operation at 240V/single phase/50Hz supply. the pump shall be supplied complete with necessary polypropylene piping, valves, strainers & injection fittings. BI01010001010000000000000515BI0100001189
79 79 Micron cartridge filter suitable to achieve particle filtration of less than 5 microns. The unit shall be supplied complete with inlet and outlet branches removal cap for replacement of element, inlet and outlet pressure indicators. BI01010001010000000000000515BI0100001190
80 80 R.O High Pressure feed pumps of vertical, multistage centrifugal type of approx. 3 hp capacity. The pump construction shall be of SS-304 & impeller shall be also SS-304. The motor shall be of TEFC suitable for a supply of 415V/3 phase/50 Hz supply. the pump shall be supplied complete with base channel coupling foundation, bolt, pressure gauge at inlet and outlet of each pump. BI01010001010000000000000515BI0100001191
81 81 (i) Total net treated water output of system = 1000 LPH BI01010001010000000000000515BI0100001192
82 82 (ii) System recovery = 50 - 60 % BI01010001010000000000000515BI0100001193
83 83 (iii) Filtration area per membrane = 85 sq.ft. BI01010001010000000000000515BI0100001194
84 84 Centralised control panel board made out of CRCA sheet min.1.6 mm thick having main contactors for all pumps (listed above) including SPP, 3 phase thermal overload relay. The control panel for monitoring and control of P.O. system shall include all required signal lamps, HRC fuses, All control and power cabling along with double earthing between the panel shall be included in the scope of supply of the contractor. BI01010001010000000000000515BI0100001195
85 85 Special anti-scalant dosing pump BI01010001010000000000000515BI0100001196
86 86 Pressure Switches to control pressure BI01010001010000000000000515BI0100001197
87 87 First fill of all chemicals and lubricants to commission and operate the plants. BI01010001010000000000000515BI0100001198
88 88 All interconnecting piping work with non return / pneumatic valves:- BI01010001010000000000000515BI0100001199
89 89 Complete thermal insulated Stainless Steel treated water storage tank of capacity 4000 Litres including all inlet/outlet connections, accessories, valves, etc. BI01010001010000000000000515BI0100001200
90 90 Activated Carbon Filter (automatic type for online installation before the Micron Filters) . The material of construction shall be composite FRP. The unit shall be supplied complete with multi-port valves, inlet and outlet branches removal caps of replacement of elements inlet and outlet pressure indicators. - 1 Set BI01010001010000000000000515BI0100001201 1 Job
91 91 Supply of factory fabricated & wired, metal clad dust & vermin proof, floor mounting type electrical control panel fabricated out of 2 mm thick CRCA sheet steel & MS channel base of 100 X 50 X 6 mm. The Panel shall meet IP 54 degree of protection using suitable neuprene gaskets where ever required. The instrument chamber shall be seperate & shall comprise of flush type digital metering system with selector switches for phase to phase & phase to neutral voltage, line current with OFF with CTs for different readings, backup protection MCBs, phase indicating LED Lights etc. The panel board shall have suitable capacity of electrolytic & electrical grade Aluminium Bus Bars insulated with PVC heat shrink sleeves & mounted on NON Hygroscopic SMC / DMC supports. No cable shall be terminated directly on to the switchgear terminal for which necessary arrangement should be made with bus bar extensions / connectors including hardwares for cable jointing. The panel board shall be compartmentalized & shall have FRP sheet protection where ever bus bar crosses from one compartment to other. The panel should be SCADA compatible so that it can be communicated through SCADA in future whenever required. All the ACBs & MCCBs shall be compatible to provide ON/OFF/Trip status on ethernet/Modbus. All major switchgears shall be of (L&T/Schneider/Siemens), Metering Instruments shall be of (L&T/AE/Optron/Procom/reputed). BI01010001010000000000000515BI0100001202
92 92 MAIN LT PANEL BI01010001010000000000000515BI0100001203
93 93 INCOMING BI01010001010000000000000515BI0100001204
94 94 2500 A 4P 50 KA EDO ACB with O/L, S/C, E/F & other necessary protections - 2 Sets BI01010001010000000000000515BI0100001205
95 95 1600 A 4P 50 KA EDO ACB with O/L, S/C, E/F & other necessary protections - 1 Set BI01010001010000000000000515BI0100001206
96 96 PROTECTION AS PER ANSI CODE No. 50, 50N, 51, 51N, 27, 32, 49, 59, 86, 95 BI01010001010000000000000515BI0100001207
97 97 BUS - COUPLER BI01010001010000000000000515BI0100001208
98 98 2500 A 4P 50 KA EDO ACB with O/L, S/C, E/F & other necessary protections - 1 Set BI01010001010000000000000515BI0100001209
99 99 INTERLOCKING BI01010001010000000000000515BI0100001210
100 100 All the Incoming & Bus Coupler ACBs shall be electrically interlocked to achieve the purpose as per site requirements & compatiliility with synchronizing panel BI01010001010000000000000515BI0100001211
101 101 METERING BI01010001010000000000000515BI0100001212
102 102 Multifunction Meter Cl 1.0 with RS - 485, CTR -/5A, PTR - 500V - 2 Sets BI01010001010000000000000515BI0100001213
103 103 R,Y, B, PHASE INDICATING LED LIGHTS - 3 Sets BI01010001010000000000000515BI0100001214
104 104 ACB ON/OFF/TRIP status LED indicator - 3 Sets BI01010001010000000000000515BI0100001215
105 105 6 A CONTROL & BACKUP MCBs - 3 Sets BI01010001010000000000000515BI0100001216
106 106 CTR -/5 A, Current Transformer, for metering instruments - 3 Sets BI01010001010000000000000515BI0100001217
107 107 CTR -/5 A, Current Transformer, for APFC Panels - 2 Sets BI01010001010000000000000515BI0100001218
108 108 CTR -/5 A, Current Transformer, for protection relays - 3 Sets BI01010001010000000000000515BI0100001219
109 109 BUS BARS BI01010001010000000000000515BI0100001220
110 110 2500 A TPN ALUMINIUM BI01010001010000000000000515BI0100001221
111 111 OUTG0ING BI01010001010000000000000515BI0100001222
112 112 63 A TPN 36 KA MCCB with necessary protections, Spreader Links & ROM, R,Y, B, LED Indicators backed up with 6A MCBs - 6 Sets BI01010001010000000000000515BI0100001223
113 113 100 A TPN 36 KA MCCB with necessary protections, Spreader Links & ROM, R,Y, B, LED Indicators backed up with 6A MCBs, Digital AM + ASS + 100/5 A CTs - 3 Sets BI01010001010000000000000515BI0100001224
114 114 125 A TPN 36 KA MCCB with necessary protections, Spreader Links & ROM, R,Y, B, LED Indicators backed up with 6A MCBs, Digital AM + ASS + 150/5 A CTs - 5 Sets BI01010001010000000000000515BI0100001225
115 115 200 A TPN 36 KA MCCB with necessary protections, Spreader Links & ROM, R,Y, B, LED Indicators backed up with 6A MCBs, Digital AM + ASS + 200/5 A CTs - 2 Sets BI01010001010000000000000515BI0100001226
116 116 250 A TPN 36 KA MCCB with necessary protections, Spreader Links & ROM, R,Y, B, LED Indicators backed up with 6A MCBs, Digital AM + ASS + 250/5 A CTs - 4 Sets BI01010001010000000000000515BI0100001227
117 117 400 A TPN 36 KA MCCB with necessary protections, Spreader Links & ROM, R,Y, B, LED Indicators backed up with 6A MCBs, Digital AM + ASS + 400/5 A CTs - 6 Sets BI01010001010000000000000515BI0100001228
118 118 500 A TPN 36 KA MCCB with necessary protections, Spreader Links & ROM, R,Y, B, LED Indicators backed up with 6A MCBs, Digital AM + ASS + 500/5 A CTs - 2 Sets BI01010001010000000000000515BI0100001229
119 119 630 A TPN 36 KA MCCB with necessary protections, Spreader Links & ROM, R,Y, B, LED Indicators backed up with 6A MCBs, Digital AM + ASS + 600/5 A CTs - 2 Sets BI01010001010000000000000515BI0100001230
120 120 800 A TPN 50 KA, Aluminium Bus Bar Links, R,Y, B, LED Indicators backed up with 6A MCBs, Digital AM + ASS + 800/5 A CTs to connect APFC Panels - 2 Sets BI01010001010000000000000515BI0100001231 1 No.
121 121 SYNCRONIZING PANEL FOR 2 x 500 kVA DG SETS BI01010001010000000000000515BI0100001232
122 122 Incoming BI01010001010000000000000515BI0100001233
123 123 800A FP EDO 50KA ACB With Microprocessor Based Release For protection Against O/C, S/C & E/F with Shunt Trip, Under Voltage Release & Closing Coil etc. - 2 Sets BI01010001010000000000000515BI0100001234
124 124 DIGITAL METERING BI01010001010000000000000515BI0100001235
125 125 Multi Function Meter with RS 485 Communication Port, CTs, Indicating Lights with Backup Protection MCBs - 2 Sets BI01010001010000000000000515BI0100001236
126 126 BUS – BARS (Main Horizontal) \n BI01010001010000000000000515BI0100001237
127 127 2000 A, TPN Aluminium Bus Bars with PVC heat shrink sleeves\nand mounted on Non hygroscopic SMC/DMC supports BI01010001010000000000000515BI0100001238
128 128 CONTROL INSTRUMENTS : BI01010001010000000000000515BI0100001239
129 129 PLC along with required modules & Software - 1 Set BI01010001010000000000000515BI0100001240
130 130 HMI / Annunciation window display - 1 Set BI01010001010000000000000515BI0100001241
131 131 Resin cast CTs 800/5A 15VA with Shorting terminals - 2 Sets BI01010001010000000000000515BI0100001242
132 132 Status Indicating Lights 24V DC - 2 Sets BI01010001010000000000000515BI0100001243
133 133 Phase Indicating Lights 230V AC (R,Y,B) - 2 Sets BI01010001010000000000000515BI0100001244
134 134 Auto / Manual Selector Switch 2P 2W - 1 Set BI01010001010000000000000515BI0100001245
135 135 Power Switch Socket 15 A - 1 Set BI01010001010000000000000515BI0100001246
136 136 Push Button with NO / NC Contacts (For Start) - 2 Sets BI01010001010000000000000515BI0100001247
137 137 Push Button with NO / NC Contacts (For Stop) - 2 Sets BI01010001010000000000000515BI0100001248
138 138 Push Button with NO / NC Contacts (For Fault accept) - 2 Sets BI01010001010000000000000515BI0100001249
139 139 Push Button with NO / NC Contacts (For Reset) - 2 Sets BI01010001010000000000000515BI0100001250
140 140 Push Button with NO / NC Contacts (For Emergency Stop) - 2 Sets BI01010001010000000000000515BI0100001251
141 141 ON / OFF Selector Switch for battery charger - 2 Sets BI01010001010000000000000515BI0100001252
142 142 24 V DC 20 A SMPS Battery Charger - 2 Sets BI01010001010000000000000515BI0100001253
143 143 DC VM Analog type 30 V - 2 Sets BI01010001010000000000000515BI0100001254
144 144 DC AM Analog type 20 A - 2 Sets BI01010001010000000000000515BI0100001255
145 145 SP Control MCB's - 2 Sets BI01010001010000000000000515BI0100001256
146 146 DP Control MCB's - 2 Sets BI01010001010000000000000515BI0100001257
147 147 FP Control MCB's - 2 Sets BI01010001010000000000000515BI0100001258
148 148 Push Buttons with Aux. Control Contacts - 2 Sets BI01010001010000000000000515BI0100001259
149 149 Control Relays 4CO 24V DC - 2 Sets BI01010001010000000000000515BI0100001260
150 150 Control Relays 4CO 230V AC - 2 Sets BI01010001010000000000000515BI0100001261
151 151 Control Contactors 24V DC - 2 Sets BI01010001010000000000000515BI0100001262
152 152 Control Contactors 230V AC - 2 Sets BI01010001010000000000000515BI0100001263
153 153 Control Connectors - 2 Sets BI01010001010000000000000515BI0100001264
154 154 Relay Board 24V DC - 2 Sets BI01010001010000000000000515BI0100001265
155 155 Power Supply 24V DC 5A - 2 Sets BI01010001010000000000000515BI0100001266
156 156 Hooter 24V DC - 2 Sets BI01010001010000000000000515BI0100001267
157 157 Cooling Fan 230V AC - 2 Sets BI01010001010000000000000515BI0100001268
158 158 Breaker control Switch 25A (TNC) - 2 Sets BI01010001010000000000000515BI0100001269
159 159 Space heater with thermostat - 2 Sets BI01010001010000000000000515BI0100001270
160 160 24V 20A rectifier with Heat Sink - 2 Sets BI01010001010000000000000515BI0100001271
161 161 Control Terminal Block 4 Sq.mm. - 2 Sets BI01010001010000000000000515BI0100001272
162 162 UPS - 1 Set BI01010001010000000000000515BI0100001273
163 163 Protection Relay if required other than incorporated in DG Controller BI01010001010000000000000515BI0100001274
164 164 PROTECTION RELAYS BI01010001010000000000000515BI0100001275
165 165 Trip Circuit Supersion Relay (95) - 2 Sets BI01010001010000000000000515BI0100001276
166 166 Master Trip Relay (86) - 2 Sets BI01010001010000000000000515BI0100001277
167 167 Under Voltage Release (27) - 2 Sets BI01010001010000000000000515BI0100001278
168 168 Over Voltage Relay (59) - 2 Sets BI01010001010000000000000515BI0100001279
169 169 RPR (32) - 2 Sets BI01010001010000000000000515BI0100001280 1 No.
170 170 Supply of factory fabricated & wired, metal clad dust & vermin proof, floor mounting type 300 kVAr Automatic Power Factor Correction Panel fabricated out of 2 mm thick CRCA sheet steel & MS channel base of 100 X 50 X 6 mm. The instrument chamber shall be seperate & shall comprise of flush type digital metering system with selector switches for phase to phase & phase to neutral voltage, line current with OFF with CTs for different readings, backup protection MCBs, phase indicating LED Lights etc. The panel board shall have suitable capacity of electrolytic & electrical grade Aluminium Bus Bars insulated with PVC heat shrink sleeves & mounted on NON Hygroscopic SMC / DMC supports. No cable shall be terminated directly on to the switchgear terminal for which necessary arrangement should be made with bus bar extensions / connectors including hardwares for cable jointing. The panel board shall have FRP / Ploycarbonate sheet protection where ever bus bar crosses from one compartment to other. All the MCCBs shall have Min. Breaking Capacity of 36 KA & MCB of 10 KA . All major switchgears shall be of (L&T/Schneider/Siemens), Metering Instruments shall be of (L&T/AE/Optron/Procom/reputed), Capacitors shall be of (L&T/Epcos/ABB) BI01010001010000000000000515BI0100001281
171 171 300 KVAr Panel Switchgears BI01010001010000000000000515BI0100001282
172 172 INCOMING BI01010001010000000000000515BI0100001283
173 173 630 A TPN 36 KA MCCB to provide protection for O/L, S/C & E/F with Spreader Links & ROM - 1 Set BI01010001010000000000000515BI0100001284
174 174 METERING BI01010001010000000000000515BI0100001285
175 175 Digital Voltmeter 0-500 V with VSS - 1 Set BI01010001010000000000000515BI0100001286
176 176 Digital Ammeter 0-600 A with CTs & ASS - 1 Set BI01010001010000000000000515BI0100001287
177 177 R,Y, B, PHASE INDICATING LED LIGHTS - 1 Set BI01010001010000000000000515BI0100001288
178 178 6 A CONTROL & BACKUP MCBs - 4 Sets BI01010001010000000000000515BI0100001289
179 179 CONTROL & AUXILIARY DEVICES BI01010001010000000000000515BI0100001290
180 180 APFC RELAY with RS - 485 - 1 Set BI01010001010000000000000515BI0100001291
181 181 Control Contactor 3NO + 3NC - 2 Sets BI01010001010000000000000515BI0100001292
182 182 Hooter System - 1 Set BI01010001010000000000000515BI0100001293
183 183 Cooling Fans with Thermostat & Timers - 4 Sets BI01010001010000000000000515BI0100001294
184 184 BUS BARS BI01010001010000000000000515BI0100001295
185 185 800 A TPN ALUMINIUM - 1 Set BI01010001010000000000000515BI0100001296
186 186 OUTGOING BI01010001010000000000000515BI0100001297
187 187 Power Factor correction Heavy duty Capacitor 40 KVAr 480 V with suitable MCCB / MCB, AC-3 duty fast acting switching devices / Thyristor backed up with 7% detuned reactor - 4 Sets BI01010001010000000000000515BI0100001298
188 188 Power Factor correction Heavy duty Capacitor 20 KVAr 480 V with suitable MCCB / MCB, AC-3 duty fast acting switching devices / Thyristor backed up with 7% detuned reactor - 6 Sets BI01010001010000000000000515BI0100001299
189 189 Power Factor correction Heavy duty Capacitor 10 KVAr 480 V with suitable MCCB / MCB, AC-3 duty fast acting switching devices / Thyristor backed up with 7% detuned reactor - 2 Sets BI01010001010000000000000515BI0100001300
190 190 ON/OFF Push Buttons - 12 Sets BI01010001010000000000000515BI0100001301
191 191 ON Indicating LED Lights - 12 Sets BI01010001010000000000000515BI0100001302 2 Nos.
192 192 Supply of factory fabricated & wired, metal clad dust & vermin proof, floor mounting outdoor type, fully automatic street light feeder pillar, fabricated out of 2 mm thick CRCA sheet steel & MS channel base of 75 X 40 X 5 mm. The instrument chamber shall be seperate & shall comprise of flush type digital metering system with selector switches for phase to phase & phase to neutral voltage, line current with OFF with CTs for different readings, backup protection MCBs, phase indicating LED Lights etc. The panel board shall have suitable capacity of electrolytic & electrical grade Aluminium Bus Bars insulated with PVC heat shrink sleeves & mounted on non Hygroscopic SMC / DMC supports. No cable shall be terminated directly on to the switchgear terminal for which necessary arrangement should be made with bus bar extensions / connectors including hardwares for cable jointing. The panel board shall have FRP / Ploycarbonate sheet protection where ever bus bar crosses from one compartment to other. All the MCCBs shall have Min. Breaking Capacity of 36 KA & MCB of 10 KA. All major switchgears shall be of (L&T/Schneider/Siemens), Metering Instruments shall be of (L&T/AE/Optron/Procom/reputed). BI01010001010000000000000515BI0100001303
193 193 INCOMING BI01010001010000000000000515BI0100001304
194 194 125 A TPN 36 KA MCCB to provide protection for O/L, S/C & with Spreader Links & ROM - 1 Set BI01010001010000000000000515BI0100001305
195 195 95 A AC-3 duty power contactor - 1 Set BI01010001010000000000000515BI0100001306
196 196 Astronomical time switch - 1 Set BI01010001010000000000000515BI0100001307
197 197 Auto / Manual Switch - 1 Set BI01010001010000000000000515BI0100001308
198 198 METERING BI01010001010000000000000515BI0100001309
199 199 Digital Voltmeter 0-500 V with VSS - 1 Set BI01010001010000000000000515BI0100001310
200 200 Digital Ammeter 0-100 A with CTs & ASS - 1 Set BI01010001010000000000000515BI0100001311
201 201 R,Y, B, PHASE INDICATING LED LIGHTS - 1 Set BI01010001010000000000000515BI0100001312
202 202 6 A CONTROL & BACKUP MCBs - 4 Sets BI01010001010000000000000515BI0100001313
203 203 BUS BARS BI01010001010000000000000515BI0100001314
204 204 150 A TPN ALUMINIUM - 1 Set BI01010001010000000000000515BI0100001315
205 205 OUTGOING BI01010001010000000000000515BI0100001316
206 206 32 A 4P 10 KA MCB (on timer) . - 6 Sets BI01010001010000000000000515BI0100001317
207 207 32 A 4P 10 KA MCB (Direct to HT room) - 1 Set BI01010001010000000000000515BI0100001318
208 208 20/25 A TPN +G IP65 Socket for general maintenance - 1 Set BI01010001010000000000000515BI0100001319 1 No.
209 209 Supply of totally enclosed HT VCB panel, floor mounting metal clad, indoor type,with Electrically operated, manually drawout type, isolation type, 11.4 kV 630 A VCB ( 2 I/C + 1 B/C + 2 O/G ), Fault Level of 18.4 kA for 1 sec. comprising of following instruments. (Schneider / L&T / C&S make) BI01010001010000000000000515BI0100001320
210 210 Incoming Feeder : 11.4 kV 630 A VCB, Fault Level of 18.4 kA for 1 sec. with aux. contactors BI01010001010000000000000515BI0100001321
211 211 Metering & Protection BI01010001010000000000000515BI0100001322
212 212 CT - 11 kV dual core 200/5A core CL1:1.0, 10VA, core Cl2:5P10 10 VA- 3 Nos. BI01010001010000000000000515BI0100001323
213 213 PT - 11 kV/110V single ph., with fuse, core-1, class-.05, 100 va dual core 200/5A core CL:1.0, 10VA - 3 Nos BI01010001010000000000000515BI0100001324
214 214 Protective Relays : BI01010001010000000000000515BI0100001325
215 215 IDMT - 1 No. BI01010001010000000000000515BI0100001326
216 216 Master Trip Relay - 1 No. BI01010001010000000000000515BI0100001327
217 217 Anti Pumping System - 1 No. BI01010001010000000000000515BI0100001328
218 218 Digital Ammeter with ASS Cl.1 - 1 No. BI01010001010000000000000515BI0100001329
219 219 Digital Voltmeter with VSS Cl.1 - 1 No. BI01010001010000000000000515BI0100001330
220 220 Indications with backup protection MCBs for RYB, ON/OFF/Trip, Spring Charge healthy, Trip Circuit healthy, test/service - 10 sets BI01010001010000000000000515BI0100001331
221 221 Others : TNC - 1 No., L/R sw. - 1 No., P/B for TCS check - 1 No., E/PB - 1 No., LED Indicator- 1 No., 3 pin socket-1No., Toggle sw. - 1 No., Door sw. - 1 No.,Space heater with thermostat - 1 set, control - 1 lot BI01010001010000000000000515BI0100001332 2 Nos.
222 222 Bus Coupler : 11.4 kV 630 A VCB, Fault Level of 18.4 kA for 1 sec. with aux. contactors - 1 No BI01010001010000000000000515BI0100001333
223 223 Protective Relays : BI01010001010000000000000515BI0100001334
224 224 Anti Pumping System - 1 No. BI01010001010000000000000515BI0100001335
225 225 Indications with backup protection MCBs for ON/OFF/Trip, Spring Charge healthy, Trip Circuit healthy, test/service - 7 sets BI01010001010000000000000515BI0100001336
226 226 Others : TNC - 1 No., L/R sw. - 1 No., P/B for TCS check - 1 No., E/PB - 1 No., LED Indicator- 1 No., 3 pin socket-1No., Toggle sw. - 1 No., Door sw. - 1 No., Space heater with thermostat - 1 set, control - 1 lot BI01010001010000000000000515BI0100001337 1 No.
227 227 Outgoing feeder : 11.4 kV 630 A VCB, Fault Level of 18.4 kA for 1 sec. with aux. contactors BI01010001010000000000000515BI0100001338
228 228 Metering & Protection BI01010001010000000000000515BI0100001339
229 229 CT - 11 kV dual core 100/5A core CL1:1.0, 10VA, core Cl2:5P10 10 VA- 3 Nos. BI01010001010000000000000515BI0100001340
230 230 Protective Relays : BI01010001010000000000000515BI0100001341
231 231 IDMT - 1 No. BI01010001010000000000000515BI0100001342
232 232 Master Trip Relay - 1 No. BI01010001010000000000000515BI0100001343
233 233 Anti Pumping System - 1 No. BI01010001010000000000000515BI0100001344
234 234 Aux. Relay - 2 Nos. BI01010001010000000000000515BI0100001345
235 235 Digital Ammeter with ASS Cl.1 - 1 No. BI01010001010000000000000515BI0100001346
236 236 Indications with backup protection MCBs forON/OFF/Trip, Spring Charge healthy, Trip Circuit healthy, test/service - 7 sets BI01010001010000000000000515BI0100001347
237 237 Others : TNC - 1 No., L/R sw. - 1 No., P/B for TCS check - 1 No., E/PB - 1 No., LED Indicator- 1 No., 3 pin socket-1No., Toggle sw. - 1 No., Door sw. - 1 No., Space heater with thermostat - 1 set, control - 1 lot BI01010001010000000000000515BI0100001348
238 238 Annunciator window 8 module - 1 No. BI01010001010000000000000515BI0100001349 2 Nos.
239 239 Decorative Lighting Poles with single arm (Luxture / Crompton/BAJAJ make) BI01010001010000000000000515BI0100001350
240 240 Length - 2 Mtr. BI01010001010000000000000515BI0100001351 10 Nos.
241 241 Length - 5 Mtr. BI01010001010000000000000515BI0100001352 20 Nos.
242 242 Length - 6 Mtr. BI01010001010000000000000515BI0100001353 5 Nos.
243 243 Length - 7 Mtr. BI01010001010000000000000515BI0100001354 5 Nos.
244 244 Length - 9 Mtr. BI01010001010000000000000515BI0100001355 5 Nos.
245 245 GI Octagonal Pole including all accessories (Philips / Crompton/BAJAJ/VALMONT make) BI01010001010000000000000515BI0100001356
246 246 Length - 2 Mtr. BI01010001010000000000000515BI0100001357 10 Nos.
247 247 Length - 5 Mtr. BI01010001010000000000000515BI0100001358 20 Nos.
248 248 Length - 6 Mtr. BI01010001010000000000000515BI0100001359 5 Nos.
249 249 Length - 7 Mtr. BI01010001010000000000000515BI0100001360 5 Nos.
250 250 Length - 9 Mtr. BI01010001010000000000000515BI0100001361 5 Nos.
251 251 GI Arms for Octagonal Pole (Philips / Crompton/BAJAJ/VALMONT make) BI01010001010000000000000515BI0100001362
252 252 Single Arm BI01010001010000000000000515BI0100001363 30 Nos.
253 253 Double Arm BI01010001010000000000000515BI0100001364 10 Nos.
254 254 PVC Junction box of size 40 mm 3 & 4 way BI01010001010000000000000515BI0100001365 500 Nos.
255 255 PVC Ferrule of size 2.5" BI01010001010000000000000515BI0100001366 5000 Nos.
256 256 PVC Cable Tie BI01010001010000000000000515BI0100001367
257 257 Length - 150 mm BI01010001010000000000000515BI0100001368 5000 Nos.
258 258 Length - 300 mm BI01010001010000000000000515BI0100001369 5000 Nos.
259 259 MS U Clamp for cable tray made of 35X35X5 mm, 2 X (1.0 mtr X 0.470 mtr) BI01010001010000000000000515BI0100001370 25 Nos.
260 260 DWC pipe of 120 mm dia (Make - Rex/Durapalst/Duraline/Opticome) BI01010001010000000000000515BI0100001371 350 Mtr.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail