| 1 | 1 | Electrification | BI01010001010000000000000515BI0100001113 | | |
|---|
| 2 | 1.01 | Supply,conveyance,installation,testing and commissioning of 24000 BTU/Hr(2 TR capacity)cold room refrigeration unit,full copper eveporation and condencing machine(Non frost type)compressure type should herrmetic or reciprocating type.The outer unit shall be closed type condensing shall be UV and corrssion resistant,inner grooved copper tube,in buit safety and control device temperature +2 degree to +6 degree maintaining coldroom.Alternating system depending on two number unit. | BI01010001010000000000000515BI0100001114 | 2 | Nos |
|---|
| 3 | 2 | Insulated refrigerentncopper piping and accessories | BI01010001010000000000000515BI0100001116 | 30 | Mts |
|---|
| 4 | 3 | Temperature controller -Microprocessor based digital temperature controller | BI01010001010000000000000515BI0100001117 | 1 | Nos |
|---|
| 5 | 4 | Change over system and power failure alarm | BI01010001010000000000000515BI0100001118 | 1 | Nos |
|---|
| 6 | 5 | Pre fabricated PUF panels-60 mm thick PUF with dencity 40+OR 2 Kg/M square wall and ceiling panels laminated with 5 mm PPGI outside cold room as per the site conditionwith necessary angels,Channels,Silicon sealing,nuts,bolts etc | BI01010001010000000000000515BI0100001119 | 510 | Ft2 |
|---|
| 7 | 6 | Supply,conveyance,installation,and commissioning of heavy duty single leaf hinged flushes door aesthetic,efficient and laminated outside and inside for cold room,camlock,sweep/magnetic gasket flexible,posi lock with heater and ramp facility and safety lock to open from inside in case of accidental closure of door.The alarm using hooter in the open area of the installation location | BI01010001010000000000000515BI0100001120 | 1 | Nos |
|---|
| 8 | 7 | Supply and providing PT 100 sencer | BI01010001010000000000000515BI0100001121 | 1 | Nos |
|---|
| 9 | 8 | Refrigerator Gas CFC free gas (410/404/22) | BI01010001010000000000000515BI0100001122 | 12 | Kg |
|---|
| 10 | 9 | Sweep gasket-air tight heavy duty sealing gasket below door with a double sweep | BI01010001010000000000000515BI0100001123 | 1 | Nos |
|---|
| 11 | 10 | Supply and fixing of vapour proof fittings inside the cooled room suitable for withstant in the 2 to 8 degree centigrade ceiling munted LED lighting with an external switch and pilot light shuold be provided | BI01010001010000000000000515BI0100001124 | 1 | Nos |
|---|
| 12 | 11 | Supply and fixing indoor and out door installation frame | BI01010001010000000000000515BI0100001125 | 2 | Nos |
|---|
| 13 | 12 | Street light fitting with 40 watts LED Steat light with Die -cast aluminium road way luminaire,high efficiency & low power consumption coolday light effect,with all accessories complete on existing pipe and giving connection with 24/020 mm 3 core flex wire as required. | BI01010001010000000000000515BI0100001126 | 2 | Nos |
|---|
| 14 | 13 | Supply,fabrication,conveyance and fixing the following sizes of B class GI pipe bent to shape/cut and welded to shape and fixing the same to wall/ parapet using clamps as noted along with each size,painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer,making good the damages,colour washing etc as required (for the installation of outdoor light fittings) --25 mm dia with HG company fabricated clamps | BI01010001010000000000000515BI0100001127 | 2 | Mts |
|---|
| 15 | 14.01 | Supply and fixing the following sizes of PVC Conduit conforming to IS 9537/1983 part III along with all required accessories on surface including making good the damages etc as required -20 mm dia light gauge | BI01010001010000000000000515BI0100001128 | 30 | Mts |
|---|
| 16 | 14.02 | Supply and fixing the following sizes of PVC Conduit conforming to IS 9537/1983 part III along with all required accessories on surface including making good the damages etc as required - 25 mm dia light gauge | BI01010001010000000000000515BI0100001129 | 25 | Mts |
|---|
| 17 | 15.01 | Supply and drawing 650/1100 V grade PVC insulated single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface/recess conduit as required including giving necessary connections of the following sizes -1.50 sq mm 3 run | BI01010001010000000000000515BI0100001130 | 20 | Mts |
|---|
| 18 | 15.02 | 2.5 sq mm 3 run | BI01010001010000000000000515BI0100001131 | 10 | Mts |
|---|
| 19 | 15.03 | 4 sq mm 2 run | BI01010001010000000000000515BI0100001132 | 10 | Mts |
|---|
| 20 | 15.04 | 4 sq mm 4 run | BI01010001010000000000000515BI0100001133 | 20 | Mts |
|---|
| 21 | 16.01 | Supply and drawing the following sizes of multi core PVC insulated & PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part 1960 in the existing surface/ recess conduit as required including giving necessary connections of the following sizes -3 core 1.5 sq.mm | BI01010001010000000000000515BI0100001134 | 40 | Mts |
|---|
| 22 | 16.02 | 3 Core 2.5sq.mm | BI01010001010000000000000515BI0100001135 | 35 | Mts |
|---|
| 23 | 17 | Supply and fixing 2 module metal box with front plate modular accessories in recess including making good the damages,colour washing etc as requied(Group B) | BI01010001010000000000000515BI0100001136 | 1 | Nos |
|---|
| 24 | 18.01 | Supply and fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required(Group B) --6 A SP 1 way switch | BI01010001010000000000000515BI0100001137 | 2 | Nos |
|---|
| 25 | 18.02 | 3 plate ceiling rose | BI01010001010000000000000515BI0100001138 | 2 | Nos |
|---|
| 26 | 19 | 4 way (8+12)-double cover TPN VERTICAL DB with provision for fixing 4P MCB/ Isolator/RCCB as incomer and SP/TPmcb as outgoing (IP 42/43) | BI01010001010000000000000515BI0100001139 | 1 | Nos |
|---|
| 27 | 20.01 | Supply and installation of the following accessories suitable for 50 Hz,AC supply conforming to IS 8828-1995/IEC 60898 of the following current ratings in the existing enclosure and giving connections as required--- 40 A four pole mini break isolator | BI01010001010000000000000515BI0100001140 | 1 | Nos |
|---|
| 28 | 20.02 | 40 A pole,30mA RCCB | BI01010001010000000000000515BI0100001141 | 1 | Nos |
|---|
| 29 | 20.03 | 6 A to 25 A,10 KA,SP MCB(C curve) | BI01010001010000000000000515BI0100001142 | 2 | Nos |
|---|
| 30 | 20.04 | 6 A to 32 A,10 KA,SP MCB(C curve) | BI01010001010000000000000515BI0100001143 | 6 | Nos |
|---|
| 31 | 21.01 | S&F switch disconnector fuse unit complete with handle assembly,door inter lock and padlocking arrangement of the following ratings:--32 A DP SDF | BI01010001010000000000000515BI0100001144 | 1 | Nos |
|---|
| 32 | 21.02 | 2-80A,DIN type fuse link of size 000 | BI01010001010000000000000515BI0100001145 | 6 | Nos |
|---|
| 33 | 22 | Supply and fixing the SMC Box gsdb1816 sintex make or eulant | BI01010001010000000000000515BI0100001146 | 2 | Nos |
|---|
| 34 | 23 | Supply and fixing the following accessories in the existing meter board and giving connections etc. -32 A fuse holder for BS type offset tag fuses | BI01010001010000000000000515BI0100001147 | 3 | Nos |
|---|
| 35 | 24 | 32 A,415 V,2 way neutral link mounted on DMC/SMC base. | BI01010001010000000000000515BI0100001148 | 1 | Nos |
|---|
| 36 | 25 | Dismantling the existing damaged wiring and allied accessories,lights,fans etc and conveyance to the section store without further damages | BI01010001010000000000000515BI0100001149 | 10 | Nos |
|---|