}

Supply Of Icu Ventilator --Kerala

Southern Railway has published Supply Of Icu Ventilator -. Submission Date for this Tender is 16-04-2020. Surgical Instrument Tenders in Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

24133638
Supply Of Icu Ventilator -
Tender
Indian
Kerala
16-04-2020

Tender Details

Supply Of , Supply Of Icu Ventilator - Technical Specification For Icu Ventilator 1. Advanced Technology High End Ventilator For Use In Icu Suitable For Ventilating Pediatric From 5 Kg Onwards To Adult Patients. Should Conform To Indian Certification, Ie Bis, And Copy Of The Certificate To Be Enclosed. 2. Should Be Micro- Processor Controlled System With Selection Of Various Ventilatory Parameters And Peep. Rapid Trigger Response Time In All Modes For Minimum Work Of Breathing Is Needed. 3. Should Work With Internal Turbine Compressor To Generate Air Flow. Weight Of The Equipment Should Not Exceed 20 Kg 4. Should Have Facility To Accept Oxygen Supply From Both Higher Pressure Source ( 40 - 80 Psi Or Wider ) And Low Pressure Sources ( 0 - 80 Lit / Min Or More ) Through Flow Meters. Ventilator Should Be Able To Deliver The Set Fio2 In Both Cases. 5. Should Provide Different Modes Of Ventilation Like Volume Assist Control, Volume Simv, Pressure Assist Control, Pressure Simv Pressure Support, Cpap, Prvc And Aprv / Biphasic. 6. Should Also Provide Non-Invasive Modes Like Cpap, Psv, Bipap 7. Should Have Built-In Leak Compensation Facility With User Selectable Switches On / Off Facility 8. Should Have Ventilation Parameters Settings Like Tidal Volume, Fio2, Flow-Rate, Pressure Support, Peep, Flow Trigger. 9. Should Display The Maintained Parameters Of Exhaled Tidal Volume, L-E. Ratio Peak Air Way Pressure, Mean Pressure. 10. Should Have Variable Inspiratory Pause Facility 11. Should Have Integrated Colour Tft Display Screen Of More Than 10 Inches With High Resolution For Display Of Parameters With Touch Screen Facility 12. Should Have Optical Selector Switch For Various Parameter Values And Menu Selection 13. Should Display Waveforms And Loops For Each Breath With Freezing Facility 14. Should Have Reusable Filters For Effective Filtering As Well As To Avoid Cross Contamination. 15. Two Sets Of Reusable Ventilator Circuit One Each For Adult And Paediatric Should Be Supplied With The System. 16. Should Have Built-In Nebulizer Facility With Nebulization Turn Adjustable 1 To 60 Minutes And Nebulizer Flow Should Be Synchronized With The Ventilator. The Necessary Accessories For Nebulizer Connection Should Be Supplied With The Ventilator As Standard Accessories. 17. Should Have A Reusable Variable Orifice Flow Sensor Mechanism At The Machine End Foraccurate Measurement Even In The Presence Of Active Humidifier. 18. Should Have Facility To Select The Inspiration Flow Pattern Between Square Wave And Decelerating Wave 19. Should Have Panel Lock Facility To Avoid Disturbance Of The Said Parameters. 20 Should Have Built-In Battery Backup For Minimum Of 4 Hours. 21 Should Have User Variable Machine Volume, Flow Cycle, Psv Cycle, Psv T-Max And Volume Limit Settings Along With Volume Sync Facility. 22. Should Have Manouvers Function Mip / Nif To Measure The Patients Inspiratory Effort During Assist And Spontaneous Breathing. 23. Should Have Facility To View The History Of Events In The Past 48 Hours. 24. Should Have Dual Limb Circuit

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail