| 1 | 1 | Dismantling and taking out old damaged PCC/Steel pole of any size and removing from site, for further disposal, complete all as specified and directed. | BI01010001010000000000000515BI0100001112 | 40 | Each |
|---|
| 2 | 2 | Dismantling and taking out old damaged stay assembly complete with stay wire, loop type insulator, wornout clamps etc of any size and removing from site of work including demolition of cement concrete, complete all as specified and directed. | BI01010001010000000000000515BI0100001113 | 14 | Per Set |
|---|
| 3 | 3 | Dismantling and taking down old wornt out ACSR conductor of any type and size complete all as specified and directed. | BI01010001010000000000000515BI0100001114 | 5.5 | Qtl |
|---|
| 4 | 4 | Dismantling and taking down old worn out MS clamps/cross arms/channels complete with nuts and bolts etc, complete all as specified and directed. | BI01010001010000000000000515BI0100001115 | 4 | Qtl |
|---|
| 5 | 5 | Dismantling and taking down old U/S HT insulators (Pin/Shackle/Disc) of any type and size, complete all as specified and directed. | BI01010001010000000000000515BI0100001116 | 147 | Each |
|---|
| 6 | 6 | Dismantling Air Break Gang Operated Switches vertical/horizontal mounted including insulators and operating mechanism for repair/replacement of broken/worn out components, insulators and lightening arrestor etc, complete all as specified. | BI01010001010000000000000515BI0100001117 | 16 | Each |
|---|
| 7 | 7 | Dismantling stay assembly including demolition of concrete,etc and including excavation, complete al as specified and directed | BI01010001010000000000000515BI0100001118 | 5 | Per Set |
|---|
| 8 | 8 | Excavation in trenches in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep for laying of cable, pole foundation, etc, complete all as specified. | BI01010001010000000000000515BI0100001119 | 1736 | Cubic Metre |
|---|
| 9 | 9 | All as per item No 8 hereinbefore but depth exceeding 1.5 meter but not exceeding 3.0 meter for poles etc, complete all as specified. | BI01010001010000000000000515BI0100001120 | 3 | Cubic Metre |
|---|
| 10 | 10 | Returning, filling in, earth including spreading, leveling watering and well ramming in layers each layer not exceeding 25cm thick each layer, complete all as specified. | BI01010001010000000000000515BI0100001121 | 1323 | Cubic Metre |
|---|
| 11 | 11 | Removal of surplus soil to a distance not exc. 50 meter and depositing where directed at a level not exc. 1.5 meter above the starting point complete all as specified. | BI01010001010000000000000515BI0100001122 | 416 | Cubic Metre |
|---|
| 12 | 12 | M&L for Precast reinforced cement concrete cable cover factory made class HV, type-I, flat, size 300mm x 180mm x 40mm for HT cable line/direction marked with embosing HT , laid flat across the cable, complete all as specified and direccted. | BI01010001010000000000000515BI0100001123 | 23778 | Each |
|---|
| 13 | 13 | M&L Dry and clean fine sand for cable cushioning to underground cable protection, complete all as specified. (Excavation and earth work measured separately). Note- Punned down thickness shall be measured. | BI01010001010000000000000515BI0100001124 | 347 | Cubic Metre |
|---|
| 14 | 14 | S&F Pre-stressed concrete pole 11.0 meter long, 152 mm X 152mm at top and 152mm X 260mm at bottom, class-9, complying with the requirement of IS-1678-1978 including painting of poles with two coats of synthetic enamel paint over a coat of cement primer with black and white strips of 30cm each up to 1.5 meter from top of PCC base and numbering of pole and two coats of white wash on PCC base, as in repairs complete all as specified . \nNote :- PCC and earth work shall be measured separately | BI01010001010000000000000515BI0100001125 | 16 | Each |
|---|
| 15 | 15 | M&L for Cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation of poles including necessary form work, fair finished to exposed surfaces without using extra cement wherever required complete all as specified. | BI01010001010000000000000515BI0100001126 | 1.152 | Cubic Metre |
|---|
| 16 | 16 | M&L for Cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate as for coping of stay assembly/feeder pillar/LT panel etc including necessary form work, fair finished surfaces without using extra cement complete all as specified. | BI01010001010000000000000515BI0100001127 | 10.5408 | Cubic Metre |
|---|
| 17 | 17 | M&L for Cement concreted (1:2:4) type B-1 using 20 mm graded stone aggregate as in foundation of electric poles/struts/ etc including necessary form work, fair finished surfaces without using extra cement complete all as specified. | BI01010001010000000000000515BI0100001128 | 2.592 | Cubic Metre |
|---|
| 18 | 18 | S&F Anti climbing device spike type fabricated out of MS flat 50mm x 6 mm in two parts with 14 Nos 230 mm long and 12mm dia spikes, sharpened ends with and including nuts, bolts & washers and welding made to shape to suit the cross section of poles including painting with two coats of aluminum paint over a coat of red oxide primer complete all as specified. | BI01010001010000000000000515BI0100001129 | 2 | Qtl |
|---|
| 19 | 19 | Supply, laying and testing cable XLPE insulated, heavy duty 11000 volts (E) grade, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables flat or circular with stranded aluminium conductor of 3 core 185 Sqmm size served laid in trenches, duct, through pipe line in floor, on pole including jointing and testing, complete all as specified. | BI01010001010000000000000515BI0100001130 | 210 | Running Metre |
|---|
| 20 | 20 | Supply, laying and testing cable XLPE insulated, heavy duty 11000 volts (E) grade, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables flat or circular with stranded aluminium conductor of 3 core 150 Sqmm size served laid in trenches, duct, through pipe line in floor, on pole including jointing and testing, complete all as specified. | BI01010001010000000000000515BI0100001131 | 1888 | Running Metre |
|---|
| 21 | 21 | Supply, laying and testing cable XLPE insulated, heavy duty 11000 volts (E) grade, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables flat or circular with stranded aluminium conductor of 3 core 120 Sqmm size served laid in trenches, duct, through pipe line in floor, on pole including jointing and testing, complete all as specified. | BI01010001010000000000000515BI0100001132 | 1427 | Running Metre |
|---|
| 22 | 22 | Supply, laying and testing cable XLPE insulated, heavy duty 11000 volts (E) grade, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables flat or circular with stranded aluminium conductor of 3 core 95 Sqmm size served laid in trenches, duct, through pipe line in floor, on pole including jointing and testing, complete all as specified. | BI01010001010000000000000515BI0100001133 | 1220 | Running Metre |
|---|
| 23 | 23 | M&L for providing GI Earth continuity 8 SWG wire on HT pole fixed with MS clamp, bolts, nuts of approved size complete all as specified & directed. | BI01010001010000000000000515BI0100001134 | 0.5 | Qtl |
|---|
| 24 | 24 | M&L Lightening arrestor expulsion type for outdoor suitable for 11 KV high tension line complete with all fittings with discharge capacity 65 Kilo amperes, including bracket clamps, nuts, bolts & washers and connection to earth wire & SWG GI wire of 4mm size, complete all as specified. | BI01010001010000000000000515BI0100001135 | 15 | Set of Three |
|---|
| 25 | 25 | M&L Earthing complete for Gang Operated Device/Lightening Arrester/Panel boards, all as shown on electrical plate No 3 of MES schedule part-I, as in repairs and as specified including the following :- (i) Galvanized steel earth plate of size 60cmsx60cmsx6mm thick buried directly in ground vertically to a depth not less than 2.25 meter below ground level with top edge of earth plate at a depth not less than 1.50 meter below normal ground level. (ii) Earth plate surrounded by and packed with char-coal and common salt in alternative layers (n.exc 15cms each layer). (iii) 4mm GI wire from earth plate to main switch board including necessary GI bolts, nuts check nuts, washers, thimbles etc. (iv) 50mm bore, light grade, GI pipe for protection to earth-strip. (v) 20mm bore, light grade, GI pipe for watering including GI funnel and wire mesh. Pipe shall be provided vertically up to top level of earth pit and then taken horizontally to the earth pit. (vi) 50mm thick pre-cast cover of cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate and MS angle iron 25x25x3mm frame including two coats of sythentic enamel painting over a coat of red oxide to exposed steel surfaces. (vii) Excavation in soft/loose soil, returning filling & removal of surplus soil to a distance up to 50 meter as directed. | BI01010001010000000000000515BI0100001136 | 16 | Each |
|---|
| 26 | 26 | S&F Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of size 50 sqmm to 95 Sqmm, complete all as specified and directed. | BI01010001010000000000000515BI0100001137 | 16 | Each |
|---|
| 27 | 27 | S&F Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of size 120 sqmm to 185 sqmm, complete all as specified and directed. | BI01010001010000000000000515BI0100001138 | 20 | Each |
|---|
| 28 | 28 | S&F Air Break Gang Operated Switch, triple pole, mechanically operated, with contacts of ferrous knife and spring loaded moving contact of copper, vertically mounted, (12 insulator type) mounted on insulator and steel frame with operating mechanism in accordance with IS-9921 including 25mm bore medium grade GI pipe to worked from ground level for current rating up to 200 Amps 11 KV with locking mechanism, mild steel clamp, nuts, bolts, washers, operating handle with in both OFF and ON position including provision of locking arrangement of required size including two coats of aluminum paint over a coat of red oxide complete all as specified. | BI01010001010000000000000515BI0100001139 | 25 | Each |
|---|
| 29 | 29 | S&F Stay assembly complete comprising of mild steel plate 300 mmx300mmx 6mm thick, mild steel galvanized stay bow 40 cm long with two nos galvanized thimbles 20mm dia of MS galvanized stay rod 180 cm long complete with & including accessories as shown in electrical plate No 1 of SSR Part-I all as specified .\nNote :-Loop type insulator, stay clamps, stay wire, excavation and concrete measured separately). | BI01010001010000000000000515BI0100001140 | 12 | Each set |
|---|
| 30 | 30 | S&F Galvanized iron stay strand of size 7/4mm complete all as specified. | BI01010001010000000000000515BI0100001141 | 0.6 | Qtl |
|---|
| 31 | 31 | S&F Loop type insulator, porcelain, vitreous white, brown or green of size 90mm x140mm and clearance of hole 25.5 mm for stay assembly, complete all as specified. | BI01010001010000000000000515BI0100001142 | 10 | Each |
|---|
| 32 | 32 | M&L for horizontal Boring holes with trenchless technology under pucca metalled road suitable for laying 150/ 100mm bore pipe for crossing cable including getting out,disposal rubbish off to a distance upto 50 metre after making good road with same material to match with existing surface, complete all as specified and as directed | BI01010001010000000000000515BI0100001143 | 200 | Running Metre |
|---|
| 33 | 33 | M&L cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, boltss washers, welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed including two coats of sythentic enamel paint over a coat of red-oxide, complete all as specified and as directed | BI01010001010000000000000515BI0100001144 | 8 | Qtl |
|---|
| 34 | 34 | S&F RCC HT cable route indicator of size 75cmx40cmx10cm duly marked with HT cable made of Cement concreted (1:2:4) type B-1 as in foundation of electric poles/struts/etc including necessary form work, fair finished embedded in PCC bed including necessary excavation and re-filling complete all as specified. | BI01010001010000000000000515BI0100001145 | 200 | Each\n Job |
|---|
| 35 | 35 | S&F Galvanized steel tube 100 mm dia light grade for laying under road crossing, complete all as specified. | BI01010001010000000000000515BI0100001146 | 150 | Running Metre |
|---|
| 36 | 36 | S&F Galvanized steel tube 150 mm dia light grade for laying road crossing, complete all as specified. | BI01010001010000000000000515BI0100001147 | 50 | Running Metre |
|---|