Drinking Water Supply and Sanitation Government Departments Closing in 0 days TDR #24111698

Providing Installation Of Elluent Quality Monitoring System Online Analyzer And Unlinking The Data To Cpcb , Hspcb Ar 3 . 75 Mld 3 . 50 Mld 2 . 00 Mld Stp Narwana

Issued by Government Departments · Narwana, Haryana
Tender Value
13.15 Lakhs
Estimated cost
Bid Submission
06 Apr 2020
0 days left
EMD
26300
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Narwana → Haryana
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Providing Installation Of Elluent Quality Monitoring System Online Analyzer And Unlinking The Data To Cpcb , Hspcb Ar 3 . 75 Mld 3 . 50 Mld 2 . 00 Mld Stp Narwana

BOQ

Narwana Town:- \"Prov. installation of effluent quality monitoring system online analyzer and uplinking the data to CPCB, HSPCB at 3.50 MLD STP Jind-Patiala road Narwana, 3.75 MLD STP Behind FCI Godown Dharodi road & 2.00 MLD STP Dablain road at Narwana Town \"DNIT for supply, Installation and commissioning of flow meter along with RTU at inlet pipe line of 3.75 MLD STP, 3.50 MLD STP & 2.00 MLD STP at Narwana Town and all other works contingent thereto.\" Rs. 13.15 Lakh
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
113.75 MLD STP Supply, Installation, testing and commissioning Electromagnetic Flow Meter at ( inlet & bypass) as per NGT guideline\nModel No: 151 MFM W R 4 2 2 0 N 300 3 D 1 2 6 1 4 2 8 P\nW:Accuracy Class & Display:± 0.5% of measured flow; 2 Line LCD R:Indicator Converter Type: Remote, field mounted\n4:Power Supply: Universal Power Supply 85 to 265VAC@45\nto 65 Hz\n2:Output:4 to 20mA\n2:Communication Interface: RS 485 (MODBUS RTU)\n0:Data Logger: Not Applicable\nN:Cable Entry:1/2\"NPT\nSensor Size (mm): 350 mm\n3:Pressure Rating(Kg/cm2):16 Kg/cm2\nD:Design of the Measuring Sensor: Flanged-DIN\n1:Flange Material: CS\n2:Sensor Lining: PTFE\n6:Electrode Material:SS316\n1:Earthing ring: None. With built-in earthing electrode.\n4:Measuring Tube:SS304\n2:Coil Housing: CS\n8:Protection Class for Sensor:IP68\nP:Approval:Non Hazardous area\nCable L=20 mtrs ( Make cimcon, endress+ Hanser / rasemount ( Emersion)/ABB one year warrenty2each
22Supply, Fixing, testing & commissioning of Remote Terminal Unit with power analyzer having inbuilt GSM / GPRS modem. iRTU configuration is 6 Digital inputs, 2 Digital Outputs & 2 Anolog Inputs. iRTU nstallation inside a panel having isolation transformer. RTU suitable for multi parameter for transferring data to MCS complete in all respect. Make CIMCON, endress+ Houser, rasemount ( Emersion)/ABB one year warrenty2each
33nstallation & accessories like Cabling as per site requirements, Panel Box etc.. Commissioning Charges of Flow Meter, Customization and programming of flow meter, Configurations as per site requirements & making connection with the existing SCADA software, Head Office, HSPCB & CPCB to the satisfaction of Engineering In-charge, including one year maintenance charges . Make CIMCON, endress+ Houser, rasemount ( Emersion)/ABB one year warrenty2per job
443.50 MLD STP Supply, Installation, testing and commissioning Electromagnetic Flow Meter at ( inlet & bypass) as per NGT guideline\nModel No: 151 MFM W R 4 2 2 0 N 300 3 D 1 2 6 1 4 2 8 P\nW:Accuracy Class & Display:± 0.5% of measured flow; 2 Line LCD R:Indicator Converter Type: Remote, field mounted\n4:Power Supply: Universal Power Supply 85 to 265VAC@45\nto 65 Hz\n2:Output:4 to 20mA\n2:Communication Interface: RS 485 (MODBUS RTU)\n0:Data Logger: Not Applicable\nN:Cable Entry:1/2\"NPT\nSensor Size (mm): 300 mm \n3:Pressure Rating(Kg/cm2):16 Kg/cm2\nD:Design of the Measuring Sensor: Flanged-DIN\n1:Flange Material: CS\n2:Sensor Lining: PTFE\n6:Electrode Material:SS316\n1:Earthing ring: None. With built-in earthing electrode.\n4:Measuring Tube:SS304\n2:Coil Housing: CS\n8:Protection Class for Sensor:IP68\nP:Approval:Non Hazardous area\nCable L=20 mtrs ( Make cimcon, endress+ Hanser / rasemount ( Emersion)/ABB one year warrenty2each
55Supply, Fixing, testing & commissioning of Remote Terminal Unit with power analyzer having inbuilt GSM / GPRS modem. iRTU configuration is 6 Digital inputs, 2 Digital Outputs & 2 Anolog Inputs. iRTU nstallation inside a panel having isolation transformer. RTU suitable for multi parameter for transferring data to MCS complete in all respect. Make CIMCON, endress+ Houser, rasemount ( Emersion)/ABB one year warrenty2each
66Installation & accessories like Cabling as per site requirements, Panel Box etc.. Commissioning Charges of Flow Meter, Customization and programming of flow meter, Configurations as per site requirements & making connection with the existing SCADA software, Head Office, HSPCB & CPCB to the satisfaction of Engineering In-charge, including one year maintenance charges . Make CIMCON, endress+ Houser, rasemount ( Emersion)/ABB one year warrenty2per job
772.00 MLD STP Supply, Installation, testing and commissioning Electromagnetic Flow Meter at ( inlet & bypass) as per NGT guideline\nModel No: 151 MFM W R 4 2 2 0 N 300 3 D 1 2 6 1 4 2 8 P\nW:Accuracy Class & Display:± 0.5% of measured flow; 2 Line LCD R:Indicator Converter Type: Remote, field mounted\n4:Power Supply: Universal Power Supply 85 to 265VAC@45\nto 65 Hz\n2:Output:4 to 20mA\n2:Communication Interface: RS 485 (MODBUS RTU)\n0:Data Logger: Not Applicable\nN:Cable Entry:1/2\"NPT\nSensor Size (mm): 300 mm \n3:Pressure Rating(Kg/cm2):16 Kg/cm2\nD:Design of the Measuring Sensor: Flanged-DIN\n1:Flange Material: CS\n2:Sensor Lining: PTFE\n6:Electrode Material:SS316\n1:Earthing ring: None. With built-in earthing electrode.\n4:Measuring Tube:SS304\n2:Coil Housing: CS\n8:Protection Class for Sensor:IP68\nP:Approval:Non Hazardous area\nCable L=20 mtrs Make CIMCON, endress+ Houser, rasemount ( Emersion)/ABB one year warrenty2each
88Supply, Fixing, testing & commissioning of Remote Terminal Unit with power analyzer having inbuilt GSM / GPRS modem. iRTU configuration is 6 Digital inputs, 2 Digital Outputs & 2 Anolog Inputs. iRTU nstallation inside a panel having isolation transformer. RTU suitable for multi parameter for transferring data to MCS complete in all respect. Make CIMCON, endress+ Houser, rasemount ( Emersion)/ABB one year warrenty2Each
99Installation & accessories like Cabling as per site requirements, Panel Box etc.. Commissioning Charges of Flow Meter, Customization and programming of flow meter, Configurations as per site requirements & making connection with the existing SCADA software, Head Office, HSPCB & CPCB to the satisfaction of Engineering In-charge, including one year maintenance charges . Make CIMCON, endress+ Houser, rasemount ( Emersion)/ABB one year warrenty2per job

AI Tender Summary

OUR REF NO 24111698
AUTHORITY Government Departments
TENDER VALUE 13.15 Lakhs
LAST DATE 06-04-2020
Authority
Authority Name Public Health Engineering Department
Work Description Providing Installation Of Elluent Quality Monitoring System Online Analyzer And Unlinking The Data To Cpcb , Hspcb Ar 3 . 75 Mld 3 . 50 Mld 2 . 00 Mld Stp Narwana
Basic Detail
Tender No EIC No.24613-14-PHED/Urban dated 28/02/2020
Bidding Type Tender
Location
City Narwana
State Haryana
Key Dates
Publish Date 24 Mar 2020
Submission Date 06 Apr 2020
Open Date 06 Apr 2020
Finance
Tender Value 13.15 Lakhs
Tender Fee 1000
EMD 26300
Exemption Not Available
Document List
B5826EB0-6D38-4556-8F6A-C3FAF9D7C08B.html
Tendernotice_1.pdf
BOQ_170886.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Mar 24, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
Apr 06, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Apr 06, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

B5826EB0-6D38-4556-8F6A-C3FAF9D7C08B.html

pdf

Tendernotice_1.pdf

xls

BOQ_170886.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders