Kdp ( District Panchayath ) - Rwss To Ponthanamkuzhi - Supplying And Erection Of V/T Pump Set And Replacing Damaged 80Mm Gi Pipe

Tender Notice

24104925
Kdp ( District Panchayath ) - Rwss To Ponthanamkuzhi - Supplying And Erection Of V/T Pump Set And Replacing Damaged 80Mm Gi Pipe
Indian
Kerala
27-05-2020
04-06-2020
06-06-2020

Tender Details

Kdp ( District Panchayath ) - Rwss To Ponthanamkuzhi - Supplying And Erection Of V/T Pump Set And Replacing Damaged 80Mm Gi Pipe , App A - Supplying And Erecting V/T Pump Set At Ponthanamkuzhi , Supply , Erection And Commissioning Of Brand New Vt Pump Set With The Following Specification . , Pump - Supply , Erection Testing And Commissioning Of Kwa Pre-Qualified Reputed Make Water Lubricated Vertical Turbine Pumpset With Bronze/Ss Impeller , Ss Shaft With Ms Erw Column Pipe Of Suitable Diameter And Length . The Pumpset Shall Be Suitable To Be Coupled With Vertical Hollow Shaft Motor . The Duty Condition Of Pumpset Are: Discharge - 1000 Lpm , Total Head 110 Meter , Delivery Size So As To Suit The Existing Pumping Main . , Motor - Supply , Erection Testing And Commissioning Of Kwa Pre-Qualified Reputed Make ( F . L . Speed Of Motor- 1400-1500 Rpm ) Screen Protected Drip Proof Squirrel Cage Vertical Hollow Shaft Induction Motor Suitable For Operation At 415 Volts 3 Phase 50 Hz . Ac Supply For The Above Pumpset . The Motor Should Confirm To Eefi/Is 325 . Supply Of Suitable Size Best Quality Isi Marked Pn 1 . 6 Heavy Duty Cast Iron Double Flanged Sluice Valve And Reflex Valve Suitable For The Above Pumpset . Fabricating And Connecting Delivery Pipe Of Required Size With Y- Connection And Necessary Joints Made Out Of Suitable Size Ms Pipe In Suitable Length With Required Flanged Joints And Seating On Supports As Per Site Condition . Supply Of Of The Motor Is Including Providing Suitable Concrete Foundation , Cost Of Cement , Sand And Metal Etc . Complete . Flexible Coupling Shall Be Used For Coupling Of Pumps And Motors , Starter - Supply , Erection Testing And Commissioning Of Suitable Rating ( Fully Automatic Starter With Air Break Contact For Less Than 100Hp And For Above 100Hp Fmca Starters To Be Used ) Starter Suitable For The Above Motor With Over Voltage And Under Voltage Protection , Single Face Preventer , Over Load Relay With Motor Protection Relay With Main Contactor And Bypass Contactor As Per Ie Rules And Code Of Practice Etc . Complete , Panel Board ( Suitable For Operating Two Pump Sets But One Pumpset At A Time ) -Supply , Erection Testing And Commissioning Of Panel Board Consisting Of Suitable Capacity Tpn Swith With Hrc Fuse/ Mccb Voltmeter With Selector Switch , Ammeter With Selector Switch , Fitted With 3 Nos . Of Indicator Lamps With All Fittings As Per Ie Rules , Panel Board Shall Have Facilities And Capacity For Operating 2 Nos Of Motor Of Above Capacity And Should Have Necessary Interlocking Arrangements . The Panel Should Have Provision For Fixing Capacitor And Giving Electric Connection To All Equipments As Per Ie Rules And Code Of Practice . Conducting Satisfactory Trial Etc . Complete As Per The Direction Of Departmental Officers . The Panel Shall Be Fitted On A Common Base Frame On Suitable Foundation . , Cabling Work - Supply , Laying , Testing And Commissioning Of Suitable Size Xlpe Cables As Per Is Standards For The Above Pumpset From Panel Board To Starter And From Starter To To Motor Considering Energy Conservations , Earthing - Supply Of Al Materials And Providing Suitable Earthing By Using Suitable Size Pipe/Plate Earthing Gi/Copper Strip Buried In Ground And Giving Double Earthing To Motor , Starter , Panel Board Etc . As Per Ie Standards With Suitable Cable And Connecting The Same To The Earth Pit Provided As Per Is 3043/ 87 And Ie Rules . And Code Of Practice Etc . Complete , Capacitor - Supply , Erection Testing And Commissioning Of Heavy Duty App Capacitor For The Motor To Get A Power Factor Above 0 . 95 . The Capacitor Shall Confirm To Is 2834 , Valves - Supply Of Suitable Size Best Quality Heavy Duty Isi Marked Ci Double Flanged Sluice Valve With Pn 1 . 6 And Non Return Valve With Suitable Pressure Rating . Fitting Of Valves Shall Include Proper Rcc Support Especially For Non Return Valves . In Case Of Positive Suction Pump Set Sluice Valve Shuold Be In Suction As Well As Delivery Sides For Easy Repair Works . , Delivery Pipe Connection - Supply And Fitting Of Suitable Size Delivery Pipe Of Best Quality Ms Of Thickness Not Less Than 10Mm For Length Required At Site And Valves , Specials Etc . Complete And Connecting The Delivery Side Of The Pump With The Pumping Main . , Total Head = 110 M . Discharge = 1000 Lpm . Rpm = 1400 -1500 Range . , App B - Laying 80Mm Gi Pipe Instead Of Damaged Pipe , Dismantling Existing Damaged 80Mm Gi Pipe With Out Causing Any Damages To Other Pipes And Stacking Into Safe Place Including Labour Charges And Hire Of Tools Etc . . Complete . , Conveying And Fixing G . I . Pipes Complete With G . I . Fittings Excluding Trenching And Refilling Etc . But Excluding Cost Of Pipes And Fittings - External Work . 80 Mm Dia Nominal Bore , Conveying And Fixing C . I . Sluice Valves ( With Cap ) By Providing Complete With Bolts , Nuts , Rubber Insertions Etc . Excluding The Cost Of Valve ( The Tail Pieces If Required Will Be Paid Separately ) :80 Mm Diameter . , Excavating Trenches Of Required Width For Pipes , Cables , Etc Including Excavation For Sockets , And Dressing Of Sides , Ramming Of Bottoms , Depth Up To 1 . 5 M , Including Getting Out The Excavated Soil , And Then Returning The Soil As Required , In Layers Not Exceeding 20 Cm In Depth , Including Consolidatingeach Deposited Layer By Ramming , Watering , Etc . And Disposing Of Surplus Excavated Soil As Directed , Within A Lead Of 50 M :All Kinds Of Soil , Providing And Fixing G . I . Union In G . I Pipe Including Cutting And Threading The Pipe And Making Long Screws Etc . Complete ( New Work ) :80 Mm Nominal Bore , Inter Connecting Newly Laid Line To The Existing Line Including Cost Of Specials , Labour Charges Etc . . . . . . Complete . , Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means Over Areas ( Exceeding 30 Cm In Depth , 1 . 5 M In Width As Well As 10 Sqm On Plan ) Including Disposal Of Excavated Earth , Lead Up To 50 M And Lift Up To 1 . 5 M , Disposed Earth To Be Levelled And Neatly Dressed . Ordinary Rock , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete , Excluding The Cost Of Centering , Shuttering , Finishing And Reinforcement - All Work Up To Plinth Level:1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , Centering And Shuttering Including Strutting , Etc . And Removal Of Form For:Foundations , Footings , Bases Of Columns , Etc For Mass Concrete , Steel Reinforcement For R . C . C Work Including Straightening , Cutting , Bending , Placing In Position And Binding All Complete Upto Plinth Levelthermo - Mechanically Treated Bars Of Grade Fe-500D Or More , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:2:4 ( Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , Shifting Water Connection And Street Tap To The Newly Laid Line Including Cost Of Materials And Labour Charges Etc . Complete , Conveying And Fixing C I Single Acting Air Valve Of Approved Quality With Bolts , Nuts , Rubber Insertions Etc . Excluding The Cost Of Air Valve ( The Tail Pieces If Required Will Be Paid Seperately ) : 25 Mm Single Acting Air Valve , App C - Cost Of Materials , Supply Of Ci Plain End Valve Conforming To Is 14846 - 2000 , Sluice Valve With Cap Pn 1 . 6 , Size 80Mm . , Supply Of Ci Air Valve , Conforming To Is 14848 - 2000 , Single Orifice , Small Orifice Type S1 , Size 25Mm . , Note: Gst @ 12% Of Bill Amount Will Be Paid Additionally .

Corrigendum Details

Sr No CorrigendumDate Description Submission Date
1 31-03-2020 2020_KWA_342932_3 25-04-2020
2 27-04-2020 Date extn due to Covid 11-05-2020
3 13-05-2020 Tender_Extn_due_to_Lockdown 25-05-2020
4 27-05-2020 Tender date extended due to Covid 19 Lockdown 04-06-2020

Key Value

Document Fees
INR 2800 /-
EMD
INR 34800.00 /-
Tender Value
INR 13.89 Lakhs /-

Attachment

FileName File Description File Size
B1B97CB1-1F1A-491F-9824-D667FB7FD8CA.html Tender Notice-Tender Notice 0
Tendernotice_1.pdf Tender Document-Tender_Notice 678.76
BOQ_495549.xls Tender Document-Price_Bid 318.00
179Form83.pdf Tender Document-Form_83 173.33
179SpecialConditions.pdf Tender Document-Special_Conditions 547.78

Other Information

Attachments
Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

BOQ Items

Name of Work: KDP (District Panchayath) - RWSS to Ponthanamkuzhi - Supplying and erection of V/T pump set and replacing damaged 80mm GI pipe.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 APP A - Supplying and erecting V/T pump set at Ponthanamkuzhi BI01010001010000000000000515BI0100001112
2 1.01 Supply, erection and commissioning of brand new VT pump set with the following specification. BI01010001010000000000000515BI0100001113 2 set
3 1.02 Pump - Supply ,erection testing and commissioning of KWA pre-qualified reputed make water lubricated vertical turbine pumpset with Bronze/SS impeller, SS shaft with MS ERW column pipe of suitable diameter and length. The pumpset shall be suitable to be coupled with vertical hollow shaft motor. The duty condition of pumpset are: discharge - 1000 lpm, Total head 110 meter, delivery size so as to suit the existing pumping main. BI01010001010000000000000515BI0100001114
4 1.03 Motor - Supply, erection testing and commissioning of KWA pre-qualified reputed make (F. L. speed of motor- 1400-1500 rpm) screen protected drip proof squirrel cage vertical hollow shaft induction motor suitable for operation at 415 volts 3 phase 50 Hz. AC supply for the above pumpset. The motor should confirm to EEFI/IS 325. Supply of suitable size best quality ISI marked PN 1.6 heavy duty cast iron double flanged sluice valve and reflex valve suitable for the above pumpset. Fabricating and connecting delivery pipe of required size with Y- connection and necessary joints made out of suitable size MS pipe in suitable length with required flanged joints and seating on supports as per site condition. Supply of of the motor is including providing suitable concrete foundation, cost of cement, sand and metal etc. complete. Flexible coupling shall be used for coupling of pumps and motors BI01010001010000000000000515BI0100001115
5 1.04 Starter - Supply ,erection testing and commissioning of suitable rating (Fully automatic starter with air break contact for less than 100HP and for above 100HP FMCA starters to be used) starter suitable for the above motor with over voltage and under voltage protection, single face preventer, over load relay with motor protection relay with main contactor and bypass contactor as per IE rules and code of practice etc. complete BI01010001010000000000000515BI0100001116
6 1.05 Panel board (Suitable for operating two pump sets but one pumpset at a time) -Supply, erection testing and commissioning of panel board consisting of Suitable capacity TPN swith with HRC fuse/ MCCB voltmeter with selector switch, ammeter with selector switch, fitted with 3 Nos. of indicator lamps with all fittings as per IE rules, panel board shall have facilities and capacity for operating 2 nos of motor of above capacity and should have necessary interlocking arrangements. The panel should have provision for fixing capacitor and giving electric connection to all equipments as per IE rules and code of practice. conducting satisfactory trial etc. complete as per the direction of departmental officers.The panel shall be fitted on a common base frame on suitable foundation. BI01010001010000000000000515BI0100001117
7 1.06 Cabling Work - Supply, laying, testing and commissioning of suitable size XLPE cables as per IS standards for the above pumpset from panel board to starter and from starter to to motor considering energy conservations BI01010001010000000000000515BI0100001118
8 1.07 Earthing - Supply of al materials and providing suitable earthing by using suitable size pipe/plate earthing GI/Copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards with suitable cable and connecting the same to the earth pit provided as per IS 3043/ 87 and IE rules. and code of practice etc. complete BI01010001010000000000000515BI0100001119
9 1.08 Capacitor - Supply ,erection testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. the capacitor shall confirm to IS 2834 BI01010001010000000000000515BI0100001120
10 1.09 Valves - Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve with PN 1.6 and non return valve with Suitable pressure rating. Fitting of valves shall include proper RCC support especially for non return valves. In case of positive suction pump set sluice valve shuold be in suction as well as delivery sides for easy repair works. BI01010001010000000000000515BI0100001121
11 1.1 Delivery pipe connection - Supply and fitting of suitable size delivery pipe of best quality MS of thickness not less than 10mm for length required at site and valves, specials etc. complete and connecting the delivery side of the pump with the pumping main. BI01010001010000000000000515BI0100001122
12 1.11 Total Head = 110 m. \nDischarge = 1000 lpm. \nRPM = 1400 -1500 range. BI01010001010000000000000515BI0100001123
13 2 APP B - Laying 80mm GI pipe instead of damaged pipe BI01010001010000000000000515BI0100001124
14 2.01 Dismantling existing damaged 80mm GI pipe with out causing any damages to other pipes and stacking into safe place including labour charges and hire of tools etc.. complete. BI01010001010000000000000515BI0100001125 30 metre
15 2.02 Conveying and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc. but excluding cost of pipes and fittings - External work. 80 mm dia nominal bore BI01010001010000000000000515BI0100001126 30 metre
16 2.03 Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) :80 mm diameter. BI01010001010000000000000515BI0100001127 1 Nos
17 2.04 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidatingeach deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All kinds of soil BI01010001010000000000000515BI0100001128 6 cum
18 2.05 Providing and fixing G.I. Union in G.I pipe including cutting and threading the pipe and making long screws etc. complete ( New work):80 mm nominal bore BI01010001010000000000000515BI0100001129 2 No
19 2.06 Inter connecting newly laid line to the existing line including cost of specials,labour charges etc...... complete. BI01010001010000000000000515BI0100001130 2 No
20 2.07 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock BI01010001010000000000000515BI0100001131 1 cum
21 2.08 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) BI01010001010000000000000515BI0100001132 0.8 cum
22 2.09 Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete BI01010001010000000000000515BI0100001133 3.3 sqm
23 2.1 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more BI01010001010000000000000515BI0100001134 80 kilogram
24 2.11 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) BI01010001010000000000000515BI0100001135 1.3 cum
25 2.12 Shifting water connection and street tap to the newly laid line including cost of materials and labour charges etc. complete BI01010001010000000000000515BI0100001136 3 No
26 2.13 Conveying and fixing C I Single acting Air Valve of approved quality with bolts,nuts,rubber insertions etc . excluding the cost of air valve(the tail pieces if required will be paid seperately): 25 mm Single acting Air Valve BI01010001010000000000000515BI0100001137 2 Nos
27 3 APP C - Cost of Materials BI01010001010000000000000515BI0100001138
28 3.01 Supply of CI Plain End Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 80mm. BI01010001010000000000000515BI0100001139 1 Nos
29 3.02 Supply of CI Air Valve, Conforming to IS 14848 - 2000, Single Orifice, Small Orifice Type S1, Size 25mm. BI01010001010000000000000515BI0100001140 2 Nos
30 4 Note: GST @ 12% of bill amount will be paid additionally. BI01010001010000000000000515BI0100001141
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.

Copyright © 2020 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail