Kdp ( District Panchayath ) - Rwss To Ponthanamkuzhi - Supplying And Erection Of V/T Pump Set And Replacing Damaged 80Mm Gi Pipe, Pathanamthitta District-Kerala

Kerala Water Authority-KWA has published Kdp ( District Panchayath ) - Rwss To Ponthanamkuzhi - Supplying And Erection Of V/T Pump Set And Replacing Damaged 80Mm Gi Pipe. Submission Date for this Tender is 29-06-2020. Earth Moving Machinery Tenders in Pathanamthitta District Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

24104925
Corrigendum : Kdp ( District Panchayath ) - Rwss To Ponthanamkuzhi - Supplying And Erection Of V/T Pump Set And Replacing Damaged 80Mm Gi Pipe
Open Tender
Indian
Kerala
Pathanamthitta District
29-06-2020

Tender Details

Kdp ( District Panchayath ) - Rwss To Ponthanamkuzhi - Supplying And Erection Of V/T Pump Set And Replacing Damaged 80Mm Gi Pipe , App A - Supplying And Erecting V/T Pump Set At Ponthanamkuzhi , Supply , Erection And Commissioning Of Brand New Vt Pump Set With The Following Specification . , Pump - Supply , Erection Testing And Commissioning Of Kwa Pre-Qualified Reputed Make Water Lubricated Vertical Turbine Pumpset With Bronze/Ss Impeller , Ss Shaft With Ms Erw Column Pipe Of Suitable Diameter And Length . The Pumpset Shall Be Suitable To Be Coupled With Vertical Hollow Shaft Motor . The Duty Condition Of Pumpset Are: Discharge - 1000 Lpm , Total Head 110 Meter , Delivery Size So As To Suit The Existing Pumping Main . , Motor - Supply , Erection Testing And Commissioning Of Kwa Pre-Qualified Reputed Make ( F . L . Speed Of Motor- 1400-1500 Rpm ) Screen Protected Drip Proof Squirrel Cage Vertical Hollow Shaft Induction Motor Suitable For Operation At 415 Volts 3 Phase 50 Hz . Ac Supply For The Above Pumpset . The Motor Should Confirm To Eefi/Is 325 . Supply Of Suitable Size Best Quality Isi Marked Pn 1 . 6 Heavy Duty Cast Iron Double Flanged Sluice Valve And Reflex Valve Suitable For The Above Pumpset . Fabricating And Connecting Delivery Pipe Of Required Size With Y- Connection And Necessary Joints Made Out Of Suitable Size Ms Pipe In Suitable Length With Required Flanged Joints And Seating On Supports As Per Site Condition . Supply Of Of The Motor Is Including Providing Suitable Concrete Foundation , Cost Of Cement , Sand And Metal Etc . Complete . Flexible Coupling Shall Be Used For Coupling Of Pumps And Motors , Starter - Supply , Erection Testing And Commissioning Of Suitable Rating ( Fully Automatic Starter With Air Break Contact For Less Than 100Hp And For Above 100Hp Fmca Starters To Be Used ) Starter Suitable For The Above Motor With Over Voltage And Under Voltage Protection , Single Face Preventer , Over Load Relay With Motor Protection Relay With Main Contactor And Bypass Contactor As Per Ie Rules And Code Of Practice Etc . Complete , Panel Board ( Suitable For Operating Two Pump Sets But One Pumpset At A Time ) -Supply , Erection Testing And Commissioning Of Panel Board Consisting Of Suitable Capacity Tpn Swith With Hrc Fuse/ Mccb Voltmeter With Selector Switch , Ammeter With Selector Switch , Fitted With 3 Nos . Of Indicator Lamps With All Fittings As Per Ie Rules , Panel Board Shall Have Facilities And Capacity For Operating 2 Nos Of Motor Of Above Capacity And Should Have Necessary Interlocking Arrangements . The Panel Should Have Provision For Fixing Capacitor And Giving Electric Connection To All Equipments As Per Ie Rules And Code Of Practice . Conducting Satisfactory Trial Etc . Complete As Per The Direction Of Departmental Officers . The Panel Shall Be Fitted On A Common Base Frame On Suitable Foundation . , Cabling Work - Supply , Laying , Testing And Commissioning Of Suitable Size Xlpe Cables As Per Is Standards For The Above Pumpset From Panel Board To Starter And From Starter To To Motor Considering Energy Conservations , Earthing - Supply Of Al Materials And Providing Suitable Earthing By Using Suitable Size Pipe/Plate Earthing Gi/Copper Strip Buried In Ground And Giving Double Earthing To Motor , Starter , Panel Board Etc . As Per Ie Standards With Suitable Cable And Connecting The Same To The Earth Pit Provided As Per Is 3043/ 87 And Ie Rules . And Code Of Practice Etc . Complete , Capacitor - Supply , Erection Testing And Commissioning Of Heavy Duty App Capacitor For The Motor To Get A Power Factor Above 0 . 95 . The Capacitor Shall Confirm To Is 2834 , Valves - Supply Of Suitable Size Best Quality Heavy Duty Isi Marked Ci Double Flanged Sluice Valve With Pn 1 . 6 And Non Return Valve With Suitable Pressure Rating . Fitting Of Valves Shall Include Proper Rcc Support Especially For Non Return Valves . In Case Of Positive Suction Pump Set Sluice Valve Shuold Be In Suction As Well As Delivery Sides For Easy Repair Works . , Delivery Pipe Connection - Supply And Fitting Of Suitable Size Delivery Pipe Of Best Quality Ms Of Thickness Not Less Than 10Mm For Length Required At Site And Valves , Specials Etc . Complete And Connecting The Delivery Side Of The Pump With The Pumping Main . , Total Head = 110 M . Discharge = 1000 Lpm . Rpm = 1400 -1500 Range . , App B - Laying 80Mm Gi Pipe Instead Of Damaged Pipe , Dismantling Existing Damaged 80Mm Gi Pipe With Out Causing Any Damages To Other Pipes And Stacking Into Safe Place Including Labour Charges And Hire Of Tools Etc . . Complete . , Conveying And Fixing G . I . Pipes Complete With G . I . Fittings Excluding Trenching And Refilling Etc . But Excluding Cost Of Pipes And Fittings - External Work . 80 Mm Dia Nominal Bore , Conveying And Fixing C . I . Sluice Valves ( With Cap ) By Providing Complete With Bolts , Nuts , Rubber Insertions Etc . Excluding The Cost Of Valve ( The Tail Pieces If Required Will Be Paid Separately ) :80 Mm Diameter . , Excavating Trenches Of Required Width For Pipes , Cables , Etc Including Excavation For Sockets , And Dressing Of Sides , Ramming Of Bottoms , Depth Up To 1 . 5 M , Including Getting Out The Excavated Soil , And Then Returning The Soil As Required , In Layers Not Exceeding 20 Cm In Depth , Including Consolidatingeach Deposited Layer By Ramming , Watering , Etc . And Disposing Of Surplus Excavated Soil As Directed , Within A Lead Of 50 M :All Kinds Of Soil , Providing And Fixing G . I . Union In G . I Pipe Including Cutting And Threading The Pipe And Making Long Screws Etc . Complete ( New Work ) :80 Mm Nominal Bore , Inter Connecting Newly Laid Line To The Existing Line Including Cost Of Specials , Labour Charges Etc . . . . . . Complete . , Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means Over Areas ( Exceeding 30 Cm In Depth , 1 . 5 M In Width As Well As 10 Sqm On Plan ) Including Disposal Of Excavated Earth , Lead Up To 50 M And Lift Up To 1 . 5 M , Disposed Earth To Be Levelled And Neatly Dressed . Ordinary Rock , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete , Excluding The Cost Of Centering , Shuttering , Finishing And Reinforcement - All Work Up To Plinth Level:1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , Centering And Shuttering Including Strutting , Etc . And Removal Of Form For:Foundations , Footings , Bases Of Columns , Etc For Mass Concrete , Steel Reinforcement For R . C . C Work Including Straightening , Cutting , Bending , Placing In Position And Binding All Complete Upto Plinth Levelthermo - Mechanically Treated Bars Of Grade Fe-500D Or More , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:2:4 ( Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , Shifting Water Connection And Street Tap To The Newly Laid Line Including Cost Of Materials And Labour Charges Etc . Complete , Conveying And Fixing C I Single Acting Air Valve Of Approved Quality With Bolts , Nuts , Rubber Insertions Etc . Excluding The Cost Of Air Valve ( The Tail Pieces If Required Will Be Paid Seperately ) : 25 Mm Single Acting Air Valve , App C - Cost Of Materials , Supply Of Ci Plain End Valve Conforming To Is 14846 - 2000 , Sluice Valve With Cap Pn 1 . 6 , Size 80Mm . , Supply Of Ci Air Valve , Conforming To Is 14848 - 2000 , Single Orifice , Small Orifice Type S1 , Size 25Mm . , Note: Gst @ 12% Of Bill Amount Will Be Paid Additionally .

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 31-Mar-2020 2020_KWA_342932_3 Date 25-04-2020
2 27-Apr-2020 Date extn due to Covid Date 11-05-2020
3 13-May-2020 Tender_Extn_due_to_Lockdown Date 25-05-2020
4 27-May-2020 Tender date extended due to Covid 19 Lockdown Date 04-06-2020
5 05-Jun-2020 Retender extn Extn Date 15-06-2020
6 16-Jun-2020 Retender extn extn Date 29-06-2020

Key Value

Document Fees
INR 2800 /-
EMD
INR 34800.0 /-
Tender Value
INR 13.89 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail