Repair/Maintenance Of Dg Set , Amf/Lt Panel And Its Connected Items At Makarpura Af Stn Baroda, GE AF BARODA-Gujarat

Military Engineer Services has published Repair/Maintenance Of Dg Set , Amf/Lt Panel And Its Connected Items At Makarpura Af Stn Baroda. Submission Date for this Tender is 13-05-2020. Spare Part Tenders in GE AF BARODA Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

24069624
Corrigendum : Repair/Maintenance Of Dg Set , Amf/Lt Panel And Its Connected Items At Makarpura Af Stn Baroda
Open Tender
Indian
Gujarat
Ge Af Baroda
13-05-2020

Tender Details

Repair / Maintenance Of Dg Set , Amf / Lt Panel And Its Connected Items At Makarpura Af Stn Baroda-1 Excavation In Trenches In Any Type Of Soil And Not Exc 1.5 M Wide And N.Exc 1.5 M In Depth For Laying Of Cable And Fixing Poles, Stays Etc And Getting Out Complete All As Specified And Directed 2 Returning, Filling In Including Spreading Leveling, Watering And Well Ramming In Layers Not Exceeding 25 Cm Thick With Excavated Soil Complete All As Specified And Directed. 3 Removing Excavated Material ( Surplus Soil ) To A Distance Not Exceeding 50 Mtrs And Depositing Where Directed At A Level Not Exc 1.5 M Above The Starting Point All As Specified And Directed. 4 M&L For Fine Dry River Sand Washed And Screened For Filling In Trenches Below And Above / Around Under Ground Cable For Cable Protection Including Punning Around Cable Complete All As Specified And Directed. Nnote : Only Punned Thickness Shall Be Measured And Paid. 5 Supply, Laying And Fixing Galvanised Iron Pipe, Light Grade, Laid Under Roads / Drain / Along With The Pole With Flat Iron Clamps, Bolts, Nuts Washers Including Taking Down Old Unservicable Existing Pipe Complete All As Specified And Directed Of Followwing Sizes :- N 6 50Mm Dia Bore. 7 40Mm Dia Bore. 8 M&L For Well Brunt Bricks Sub Class B Old Size As In Cable Protection Laid Flat Width Wise Complete All As Specified And Directed. 9 Supply, Laying, Jointing And Testing Of Lt Underground, Xlpe Insulated Screened Pvc Bedded, Galvanised Steel Strip Or Wire Armoured, Heavy Duty, Electric Power Cable Laid In Trenches / Ducts / Fixed On Pole / Wall / Laid Under Road / Path / Culvert / Drains / Culverts Encased In Gi Pipe, Electric Cable With Aluminium Stranded Conductor, Including Jointing And Testing 1100 Volts Grade With Necessary Lugs And Compression Brass Glands Complete All As Specified And Directed Includig Taking Down Old Unservicable Cable Of Any Size Any Type . 10 120 Sq Mm 3.5 Core 11 95 Sqmm 3.5 Core 12 70 Sqmm 3.5 Core 13 50 Sqmm 3.5 Core 14 25 Sq Mm 4 Core 15 16 Sqmm 4 Core 16 10 Sqmm 2 Core 17 M&L For Straight Through Joint Outdoor Type For Lt Ug Cable Including Jointing Kits Heat Shrinkable Type Complete Suitable For Aluminium Conductor Cables Complete All As Specified And Directed Of The Following Size. 18 25 To 50 Sqmm 3.5 Core 19 70 To 150 Sqmm 3.5 Core 20 Supply And Fix In Repairs Mccb 4 Pole 400 Amps , 415 Volts, 25 Ka Complete All As Specified And Directed. 21 Supply And Fix In Repairs Mccb 4 Pole 250 Amps , 415 Volts, 25 Ka Complete All As Specified And Directed. 22 Supply And Fix In Repairs Mccb 4 Pole 200 Amps , 415 Volts, 25 Ka Complete All As Specified And Directed. 23 Supply And Fix In Repairs Mccb 4 Pole 160 Amps , 415 Volts, 25 Ka Complete All As Specified And Directed. 24 Supply And Fix In Repairs Mccb 4 Pole 63 Amps , 415 Volts, 16 Ka Complete All As Specified And Directed. 25 Supply And Fix In Repairs Mccb 4 Pole 100 Amps , 415 Volts, 16 Ka Complete All As Specified And Directed. 26 Supply And Fix In Repairs Isolator 4 Pole 100 Amps , 415 Volts, 16 Ka Complete All As Specified And Directed. 27 Supply And Fix In Repairs Isolator 4 Pole 63 Amps , 415 Volts, 16 Ka Complete All As Specified And Directed. 28 Supply And Fix In Repairs Aluminium Cable Lugs Of Following Size;- 29 120 Sq Mm 30 95 Sqmm 31 70 Sqmm 32 50 Sqmm 33 35 Sqmm 34 25 Sq Mm 35 10 / 16 Sqmm 36 Taking Down Old Unserviceable Mcb And Supply And Fix Mcb, Single Pole And Neutral Link 240 Volts 40 To 63 Amps Capacity B Series Fixed In Dbs. 37 Taking Down Old Unserviceable Mcb And Supply And Fix Mcb, Single Pole 240 Volts 40 To 63 Amps Capacity B Series Fixed In Dbs. 38 Supply And Fix In Repairs The Following Component In Existing Lt Panel Boards Including Disconnecting And Taking Down Old Component At Different Location Complete All As Specified And Directed:- 39 Voltmeter Digital Type 0- 500 Volts 40 Ammeter Digital Type Of 400 Amps Capacity 41 Selector Switch For Voltmeter / Ammeter. 42 Phase Indicator Lamp Neon Type Complete With Holder Assy Ryb 43 Ct Coils Any Capacity. 44 Thermoplastic Cable Junction Boxes Of Size, 10 To 25 Sq Mm Ip 66 Weather Proof For Out Door Installation. 45 Blank 46 Servicing And Repair To Apfc Panel 75 To 125 Kvar Capacity Complete Including Wiring With Suitable Copper Wire Isi Marked With Indicating Lamp, Ampere Meter, Voltmeter, Capacitor And Required Items For Working Condition Complete All As Specified And Directed. Nnote :- ( I ) Capacitor Shall Be Measured And Paid Seperately As Supply Only Under Item 22.01 To 22.04. 47 Supply Only Capacitor 5 Kvar Capacity 48 Supply Only Capacitor 10 Kvar Capacity 49 Supply Only Capacitor 15 Kvar Capacity. 50 Supply Only Capacitor 20 Kvar Capacity. 51 Note : Rate Quoted For Item No 22 Is Deemed To Include For Fixing Element Of Capacotor Under Item No 22.01 To 22.04 52 Supply And Fix In Repair Of Contactors Suitable For 20 Kvar Tp Complete All As Specified And Directed Of Make L &T Cat No. Mo C 20 Cs 90021 & Cs 90022 Or Equivalent Make Of Siemens, Legrand. 53 Supply And Fix In Repair Of Contactors Suitable For 12.5 Kvar Tp Complete All As Specified And Directed Of Make L &T Cat No. Mo C12.5 Cs 96321 & Cs 96338 Or Equivalent Make Of Siemens, Legrand 54 Supply And Fix In Repair Aipfc ( Automatic Intelligent Power Factor Corrector ) Controller Micro Processor Relay 12 Stage Complete All As Specified And Directed. N 55 Supply And Fix In Replacement On Load Changeover Switch Of Capacity 200 Amps 4 Pole Including Taking Down Old Changeover Switch Any Type And Necessary Fixing On Wall / In Lt Panel Complete All As Specified And Directed Of Make L&T Cat No. Co22000oooo Or Equivalent Make Of Havells , C&S. 56 Servicing / Repair Including Preventive Check And Operational Check Of 2 Ton Eot Crane For Dismantling Of Hoisting Gear Box, Drain Of Old Oil, Cleaning Of Gear Box, Fill Up Fresh Oil In Gear Box. Long Travel, Cross Travel Gear Box Oil Check Up And Filling Oil. Checking Of Hoisting, Long Travel, Cross Travel, Break Unit, Shifting Of Berak Unit, Oiling Of Break Unit Pins. Greasing In Long Travel Cross Travel Wheel Bearing, Checking Of Panel Board And Connections, Overhauling Of Ppb, Greasing On Wire Rope Drum , Checking Of Push Button Connections Checking Of Power Festooning Cable Checking Of Long Travelo Rail Alignment, Checking Of Cross Travel Rail Alignment Bottom Block Assembly ( Hook Assembly ) Cleaning, Checking And Oiling Greasing Of Wire Rope, Rope Drum, Pedestal Bearings Including Load Test Using Dead Weight, Duly Sign By User And Sumbit To Age E / M Office Timely Complete All As Specified And Directed. Nnote : ( I ) The Spares Required For These Item Shall Be Mesured And Paid Under Item No 28.00 As A Supply Only 57 ( Ii ) Contractor Will Provide Necessory Oil, Grease, Cloth Waste And Minor Spares Required And Shall Deemed To Be Included In Quoted Rate. N ( Iii ) Load Test Will Be Carried Out After Completion Of The Entire Work And A Certificate Duly Signed By The User Will Be Submitted By The Contractor. N ( Iv ) Operational Check To Be Carried Out By Competent Person Of Authorised Firm Only. N 58 Supply Only The Following Spares For Eot / Hot Crane Complete All As Specified And Directed. Nnote : Fixing Element Of These Items Shall Deemed To Be Included In Quoted Rate Under Item No 27.00. 59 Long Travel Limit Switch As Per Existing Make 60 Cross Travel Limit Switch As Per Existing Make 61 Brake Unit For Hoising As Per Existing Make 62 Single Phase Preventor As Per Existing Make 63 Brake Set As Per Existing Make 64 Latch As Per Existing Make 65 Free Wheel As Per Existing Make 66 Gear Oil 67 Push Button As Per Existing Make 68 M&L For 1.5 Ton Hot Crane For Oiling And Greasing Of Long Travelo Rail Alignment, Checking Of Cross Travel Rail Alignment Bottom Block Assembly ( Hook Assembly ) Cleaning, Checking And Oiling Greasing Of Wire Rope, Rope Drum, Pedestal Bearings Including Load Test Using Dead Weight, Duly Signed By User And Sumbit To Age E / M Office Timely Complete All As Specified And Directed. 69 Note:- N ( I ) Contractor Will Provided Necessory Oil, Grease, Cloth Waste And Minor Spares Required And Shall Deemed To Be Included In Quoted Rate. N 70 M&L For Opening, Dismantling, Servicing And Repair To Ups 3 Phase. Input Voltage 300-480 Volts And Output Voltage 240 Volt Ac Supply 50 Hz Any Type Size, And Make Capacity 30 Kva Replacing Burnt / Wornout Spares, And Asembling After Repair And Testing On Load At Site Including Provision Of Following Spare Parts Complete All As Specified And Directed. 71 Driver Card 30 Kva Ups - 1 Nos Of Existing Make 72 Igbt Relay 30 Kva Ups- 1 Nos Of Existing Make 73 Rectifier Card 30 Kva Ups - 1 Nos Of Existing Make 74 Diode Pn 30 Kva Ups - 1 Nos Of Existing Make 75 In Put Filer Card 30 Kva Ups - 1 Nos Of Existing Make 76 Cvcd Pcb 30 Kva Ups - 1 Nos Of Existing Make 77 Mosfet 30 Kva Ups - 1 Nos Of Existing Make 78 M&L For Opening, Dismantling Servicing And Repair To Ups 3 Phase. Input Voltage 300-480 Volts And Output Voltage 240 Volt Ac Supply 50 Hz Any Type Size, And Make Capacity 10 Kva Replacing Burnt / Wornout Spares, And Asembling After Repair And Testing On Load At Site Including Provision Of Following Spare Parts Complete All As Specified And Directed. 79 Power Card 10 Kva Ups- 1 Nos Of Existing Make 80 Control Card 10 Kva Ups -1 Nos Of Existing Make 81 Igbt 10 Kva Ups -1 Nos Of Existing Make 82 Harmonic Filter 10 Kva Ups -1 Nos Of Existing Make 83 M&L For Opening, Dismentaling And Repair To Voltage Stablizer Servo Controlled Single Phase. Input Voltage 180 Volts And Output Voltage 230 Volt Ac Supply 50 Hz Any Type Size, And Make Capacity 2 To 5 Kva Replacing Burnt / Wornout Spares, Cable, Neon Lamp With Holders, Micro Switches, Dpdt Switch Auto Mannual Toggle Switch And Connector Etc And Reassembling After Repair And Testing On Load At Site Complete All As Specified And Directed. N 84 M&L For Rewinding Of Stabilizer Up To 5 Kva Transformer With Super Enamelled Copper Winding Wire Of Existing Size And Gauge And Adequate Number Of Turns Including Varnishing Insulating Material Drying Baking Heating And Connection Leads With Thimble And Making Connection Including Taking Down U / S Winding Complete All As Specified And Directed. N 85 Supply , Installation, Commissioning & Testing Out Door Lt Feeder Pillar Box Made Out Of 3.0 Mm Thick Steel Sheet And Angle Iron Supports Complete , Factory Made , Plinth Mounted, Cubical Type, Dust And Vermin Proof, Front, Back, And Sides Openable Duly Provided With Bus Bar Chamber, Cables Entry Chamber, Cabinets Of Suitale Sizes For Housing, Mccbs Metering Cabinet For Fixing Voltmeter, Ammeter And Indicators Lamp And Painted With Two Coats Of Synthetic Enamel Paint ( Powder Coated ) Over One Coat Of Red Oxide Primer And Using Copper Bus Bar Of 300 Amps Rating For Phase And Half Of The Rating Of Neutral Duly Fixed With Suitable Insulators And Nuts And Bolts, Provisions Of Threaded Earthing Stud At Bottom And Lifting Lugs Of Suitable Size At Top To Lift The Panel .Safety Shall Be Made With Degree Of Protection Of Outer Shell Ip-54 , The Cubical Shall Have A Bottom Angle Of Size 50X50x6mm Duly Coated With Zinc Metal Coating , Pcc Foundation ( 1:2:4: ) Type B-2 Using 40 Mm Grade Stone Aggregatefor Foundation As Recommended By Manufacturer Including Grouting Of Bolts, Nuts And Washers All As Directed Omprising Of The Following Incoming And Outgoing Feeder Control Complete All As Specified And Directed For Officer Qtr Near Children Park. 86 Incoming 87 Mccb 250 Amps, 4 Pole, 25 Ka -01 No; 88 Voltmeter Digital Type 0 To 500 Volts With Selector Switch- 01 No. 89 Ampere Meter Digital Type 0 To 300 Amp With Selector Switch- 01 No. 90 03 Nos Phase Indicating Lamps Backed Up With Hrc Fuse / Mcb. N02 Nos On / Off Indicating Lamps On Incomer Feeder For Indicating The Status Of Feeder. N 91 Outgoing 92 Mccb 100 Amps, 3 Pole, 25 Ka -04 No; 93 Supply , Installation, Commissioning & Testing Out Door Lt Feeder Pillar Box Made Out Of 3.0 Mm Thick Steel Sheet And Angle Iron Supports Complete , Factory Made , Plinth Mounted, Cubical Type, Dust And Vermin Proof, Front, Back, And Sides Openable Duly Provided With Bus Bar Chamber, Cables Entry Chamber, Cabinets Of Suitale Sizes For Housing, Mccbs Metering Cabinet For Fixing Voltmeter, Ammeter And Indicators Lamp And Painted With Two Coats Of Synthetic Enamel Paint ( Powder Coated ) Over One Coat Of Red Oxide Primer And Using Copper Bus Bar Of 400 Amps Rating For Phase And Half Of The Rating Of Neutral Duly Fixed With Suitable Insulators And Nuts And Bolts, Provisions Of Threaded Earthing Stud At Bottom And Lifting Lugs Of Suitable Size At Top To Lift The Panel .Safety Shall Be Made With Degree Of Protection Of Outer Shell Ip-54 , The Cubical Shall Have A Bottom Angle Of Size 50X50x6mm Duly Coated With Zinc Metal Coating , Pcc Foundation ( 1:2:4: ) Type B-2 Using 40 Mm Grade Stone Aggregatefor Foundation As Recommended By Manufacturer Including Grouting Of Bolts, Nuts And Washers All As Directed Omprising Of The Following Incoming And Outgoing Feeder Control Complete All As Specified And Directed For 57 Asp Air Store. 94 Incoming 95 Mccb 320 Amps, 4 Pole, 36 Ka -01 No; 96 Voltmeter Digital Type 0 To 500 Volts With Selector Switch- 01 No. 97 Ampere Meter Digital Type 0 To 150 Amp With Selector Switch- 01 No. 98 03 Nos Phase Indicating Lamps Backed Up With Hrc Fuse / Mcb. 02 Nos On / Off Indicating Lamps On Incomer Feeder For Indicating The Status Of Feeder. N 99 Outgoing 100 Mccb 250 Amps, 3 Pole, 25 Ka -02 No; 101 Mccb 160 Amps, 3 Pole, 25 Ka -02 No; 102 Mccb 100 Amps, 3 Pole, 25 Ka -01 No; 103 M& L For Making Proper Connection Of Loose / Hanging Lighting Arrester Aluminium / Copper / G I Strip Strip On Existing Position With Porcelain Saddles , Brass Screw Including Drilling And Fixing With Entire Satisfaction To Engineer In Charge . Nnote :- Rate Include For Any Height Of Bldg ( Roof / Wall Etc ) . After Completion Signature Shall Be Obtained By The User And Engr-In-Chage. 104 S&F In Repairs Air Termination Single Pointed, Aluminium Rod 12Mm Dia And 300Mm Long Complete All As Specified And Directed. 105 S&F In Repairs Test Point Terminal Block Made Of Ms Powder Coated Ms Sheet Of 1.6Mm Thick Sheet Of Size 230X230x 75Mm Drilled And Screwed Including Terminals For Two Strips Entry And Exit With Overlapping For Testing Earth Result Complete All As Specified And Directed. N 106 Taking Down Old Unserviceable Gi Tubing Of Air Termination Rod And S&F Gi Tubing Light Grade 40Mm Dia Bore Suitable For Air Termianation Rod Including Pcc 1:2:4 Type-B1 Of Block Size 100Mmx100mmx100mm Complete All As Specified And Directed. 107 Servicing Of Dg Set Including Replacement Of Fuel Filters, Oil Filters, Air Filter Element, Changing Oil, Cleaning Fuel Lines, Checking Leakage And Repairing It, Replacement Of Exhaust Main Fold Gasket Etc All As Specified And Directed By Engineer In Charge All As Per Manufacturer / Authorised Service Centre For The Following:- Nnote. ( I ) Rate Quoted Shall Be Included Attending Any Fault ( Start / Stop ) Or Other Defects On Emergency Basis By Technecian For The Entire Period Of Contract .No Extra Cost Will Be Paid To The Contractor For The Same. N ( Ii ) Supply Only Of Spare Shall Be Measured And Paid Under Item No 41.00. 108 12.5 / 15 Kva 109 20 Kva 110 25 Kva 111 30 Kva 112 50 Kva 113 82.5Kva 114 125 Kva 115 Supply Only The Following Spares In Replacement / Fixing At Site For Dg Sets / Amf Panels Complete All As Specified And Directed. 116 Fuel Flexible Pipe Wire Braded, 1, 1 / 4To 3 / 8Pvc Best Quality As Per Existing Make. 117 Oil Pressure Gauge Complete. Make:Pricol / Yenkey 118 Oil Pressure Switch Complete. Make:Pricol / Yenkey 119 Water Temperature Gauge Make: Pricol / Yenkey 120 Ignition Switch Make: Pricol / Yenkey 121 Indicating Lamp 122 Battery Terminal Heavy Duty Of Brass As Per Existing Make. 123 Distilled Water. 124 Coolant For Radiator. Sealed Bottle 125 Element Air Cleaner For Upto 25 Kva Dg Set Make:Make: Pricol / Yenkey 126 Oil Filter Make:Cumins / Pricol 127 Fuel Filter Set. Make: Cumins 128 Engine Oil Premium Blue 20W40 129 Fan Belt. Make Fenner / Dunlock 130 Self Starter 12 Volts Make:Lucas / Tvs 131 Self Starter 24 Volts Make:Lucas / Tvs 132 Gasket Set 133 Fuel Injector Pump Up To 30 Kva 134 Avr 82.5 Kva 135 Avr 30 Kva 136 Battery Lead 1.5 Meter Long 16 Sq Mm Copper Conductor 137 Battary Charger 138 Dynamo 12 Volt 139 Solenoid Valve 140 Coupling 30 Kva To 82.5 Kva 141 Battary 12 Volt 150 Ah 142 Battary 12 Volt 180 Ah 143 Note: Fixing Element Of Supply Only Items Shall Deemed To Be Included In Rate Quoted For Iterm No 40.00. 144 Dismantling And Taking Out Worn Out Engine Of 125 Kva Dg Set From Foundation And Transporting To Work Shop For Repair / Replacement Of Worn Out Parts And Re-Assembling Of Engine And Transporting Back And Refixing In It’S Original Place Commissioning And Testing Complete Including Taking Down Unserviceable Parts And Carrying Out Repair / Replacement Of Worn Out Parts Of Existing Make By New One And Making Panel Serviceable And Functional And Carrying Out Testing As Specified And Directed. Nnote. ( I ) Rate Quoted Shall Be Included Attending Any Fault ( Start / Stop ) Or Other Defects On Emergency Basis Of Technecian For The Entire Period Of Contract .No Extra Cost Will Be Paid To The Contractor For The Same. N ( Ii ) Supply Of Spare Shall Be Measured And Paid Under Item No 43.00 Only. 145 Supply Only The Following Spares In Replacement / Fixing At Site For Dg Sets / Amf Panels Complete All As Specified And Directed. 146 Supply Only Piston Of Existing Make. 147 Supply Only Piston Ring Of Existing Make. 148 Supply Only Con Rod Bearing Of Existing Make. 149 Supply Only O Ring Set Of Existing Make. 150 Supply Only Air Filter Assembly Of Existing Make. 151 Supply Only Oil Filter Assembly Of Existing Make. 152 Supply Only Oil Pressure Switch Of Existing Make. 153 Supply Only Water Temperature Switch Of Existing Make. 154 Supply Only Radiator Fan Of Existing Make. 155 Supply Only Fan Belt Of Existing Make. 156 Supply Only Cylinder Liner Of Existing Make. 157 Supply Only Fuel Hose Pipe Set Of Existing Make. 158 Supply Only Upper Engine Gasket Set. 159 Supply Only Lower Engine Gasket Set. 160 Supply Only Water Pump Of Existing Make. 161 Supply Only Packing Set 162 Supply Only Relay Card Of Existing Make. 163 Supply Only Water Manifold Of Existing Make. 164 Supply Only Wiring Harness 165 Supply Only Battary 12 V Exide 100 Ah 166 Supply Only Avr Of Existing Make. 167 Supply Only Diode Of Existing Make. 168 Rewinding Of Main Armature, Main Field, Exiter Armature And Exiter Field With Super Enamelled Copper Winding Wire Of Existing Size And Gauge And Adequate Number Of Turns Including Varnishing Including Taking Down Unservicable Rewinding Material Complete All As Specified And Directed. 169 Note: Fixing Element Of Supply Only Items Shall Deemed To Be Included Under Item No 42.00 170 Repair / Replacement Of Foam Of Ecoustic Enclosure With New Foam ( For 125Kva Dg Set ) , Replacement Of Door Mating Including Painting Complete All As Specified And Directed. 171 M & L For Calibration And Cleaning Of The Existing Pt Pump ( For 125Kva Dg Set ) With Replacement Of Shaft Fuel Pump Drive, Hub Coupling, Gasket Set And Governor Barrel & Plunger Etc Complete All As Specified And Directed. 172 M & L For Calibration Of The Existing Injector Assembly ( For 125Kva Dg Set ) With Replacement Of Kit Injector’S Adjustment Complete All As Specified And Directed. 173 Repairing Of Existing Head Assembly, Cleaning And Taking Out Worn Out Valves And Seat And Guide And Fitting Only New Seat Guide And Valve And Grinding Polishing ( For 125Kva Dg Set ) . 174 Servicing Of Amf Panel With Neecessary Testing Including Replacement Of Unserviceable Parts All As Specified And Directed By Engineer In Charge All As Per Manufacturer / Authorised Service Centre :- Nnote. ( I ) Rate Quoted Shall Be Included Attending Any Fault ( Start / Stop ) Or Other Defects On Emergency Basis Of Technecian For The Entire Period Of Contract .No Extra Cost Will Be Paid To The Contractor For The Same. N ( Ii ) Supply Only Of Spare Shall Be Measured And Paid Under Item No 49.00. 175 Supply Only The Following Spares In Replacement / Fixing At Site For Amf Panels Complete All As Specified And Directed. Note : Fixing Element Of Supply Only Items Shall Deemed To Be Included Under Item No 48.00 176 Supply Only Failure Timer As Per Existing Make. 177 Restoration Timer As Per Existing Make. 178 Auxillary Contactor 3 Phases Suitable For Amf Panel As Per Existing Make. 179 Amf Module As Per Existing Make. 180 Nc / No Relay Complete As Per Existing Make. 181 Under Voltage Relay As Per Existing Make. 182 Time Delay Relay As Per Existing Make. 183 C T Coil Of 5 / 150 For 125 Kva Dg Set As Per Existing Make. 184 C T Coil Of 5 / 50 For 63To 82.5 Kva Dg Set As Per Existing Make. 185 C T Coil Of 5 / 250 For 50Kva D G Set 186 Contractor 4 Pole 250 Amps For 125 Kva Dg Set 187 Contractor 4 Pole 250 Amps For 82.5 Kva Dg Set 188 Contractor 4 Pole 250 Amps For 50 Kva Dg Set 189 Battary Charger In Amf Panel 190 Controller For 82.5 Kva To 200 Kva As Per Existing Make. 191 Controller Up To 63 Kva As Per Existing Make. 192 Vmr 3 Phases For 82.5 Kva To 125 Kva As Per Existing Make. 193 Contractor Relay For 82.5 Kva To 200 Kva 194 Contractor Relay For 10 Kva To 62.5 Kva 195 Hrc Fuse 196 Repair Of Canopy With Replaced Door , Acrylic Sheet And Locks - Keys 197 Rewinding Of Dg Set Alternator 125 Kva 198 Fuse Holders For British Pattern Fuse Links Up To 63 Amp 199 Fuse Base For Din Type Fuse Links Up To 200 Amps 200 Hrc Fuse Links 125 / 160 / 200 Amp 201 Acrylic Sheet Suitable For Dg Set Canopy Matching With Existing Size And Thickness 202 M&L Cleaning And Descaling Of Radiator Assembly By Using Suitable Chemical ( Mac Solution ) And By Blower Fan And By Injecting Water In High Pressure In Water Tubings So As To Remove All Dirts Etc In The Fins Complete All As Directed For Dg Set Of Following Capacity:- 203 125 Kva 204 82.5 Kva 205 50 Kva 206 25 / 30 Kva 207 12.5 Kva 208 M&L For Providing Earthing Complete With Galvanised Steel Earth Plate Electrode 60Cm X 60Cm X 6Mm Thick Buried Directly In Ground ( Earth Pit Not Less Than 2.25 Meters Deep Below Ground Level ) With Top Edge Of The Plate Not Less Than 1.5 Meters Below Normal Ground Level, Connected To Galvanised Earth Lead 25X4mm Gi Strip Upto 7.5 Meter Long By Means Of Bolts, Nuts Check Nuts And Washers Of All Galvanised Iron Or Steel All As Shown In Electrical Plate No.3 Of Ssr Part-1 And Connected To Test Point Including Necessary Excavation / Earth Work In Any Type Of Soil / Rock Strata, Pcc 1:3:6 Type C1 Cement Concrete 1:2:4 Type B1 Reinforced With Welded Steel Wire Fabric ( Amp ) Not Less Than 4 Kg Per Sqm Funnel With Wire Mesh And Watering Pipe 20 Mm Dia Bore ( Gi Light Grade ) , Pcc Pit With 50Mm Thick Pcc Cover Etc. Including Testing On Completing Including Gi Protection Pipe 32Mm Dia Medium Grade For Earthing Lead Complete All As Specified And Directed Including Demolition Of Old Unservicable Earthing. 209 Repair / Servicing Of Existing Electronically Controlled Mechanised Target In Addition To Replacement Of Defective Components Complete All As Specified And Directed Nnote : ( I ) Supply Only Of Spare Shall Be Measured And Paid Under Item No 53.00. 210 Supply Only The Following Spares In Replacement / Fixing At Site For Moving Target Complete All As Specified And Directed. Nnote : Fixing Element Of Supply Only Items Shall Deemed To Be Included Under Item No 52.00 211 Rails For Running Target 212 Programmable Central Contorl Unit 213 Logical Contorl Unit

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 06-05-2020 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 13-05-2020
2 24-04-2020 CORRIGENDUM 2 FOR CRITICAL DATE Date 06-05-2020
3 26-03-2020 CORRIGENDUM 1 FOR CRITICAL DATE Date 27-04-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 38000.0 /-
Tender Value
INR 19 Lakhs /-