Completion Of Incomplete Left Over Works For Provision Of 2 Mw Solar Power Plant At Jalipa Under Ge Army Barmer, Barmer-Rajasthan

Military Engineer Services-MES has published Completion Of Incomplete Left Over Works For Provision Of 2 Mw Solar Power Plant At Jalipa Under Ge Army Barmer. Submission Date for this Tender is 22-06-2020. Solar Power Plants Tenders in Barmer Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

24061041
Corrigendum : Completion Of Incomplete Left Over Works For Provision Of 2 Mw Solar Power Plant At Jalipa Under Ge Army Barmer
Open Tender
Indian
Rajasthan
Barmer
22-06-2020

Tender Details

Completion Of Incomplete Left Over Works For Provision Of 2 Mw Solar Power Plant At Jalipa Under Ge Army Barmer

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 30-Mar-2020 Corrigendum 1 Critical dates Date 28-04-2020
2 17-Apr-2020 Corrigendum 02 Amendment to critical dates Date 14-05-2020
3 28-Apr-2020 Amendment to BOQ BOQ 14-05-2020
4 05-May-2020 Amendment to dates Date 27-05-2020
5 18-May-2020 Amendment to critical dates Date 01-06-2020
6 22-May-2020 Revised critical dates Date 02-06-2020
7 30-May-2020 Corrigendum for critical dates Date 05-06-2020
8 03-Jun-2020 Corrigendum of critical dates Date 11-06-2020
9 08-Jun-2020 Corrigendum No 09 Other 11-06-2020
10 09-Jun-2020 Corrigendum 10 Date 15-06-2020
11 15-Jun-2020 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 22-06-2020

Key Value

Document Fees
INR 3000 /-
EMD
INR 965000.0 /-
Tender Value
INR 12.80 Crore /-

BOQ Items

Name of Work: COMPLETION OF INCOMPLETE WORK OF PROVISION OF 2 MW SOLAR POWER PLANT (JOB No. SC/MW/1255) AT JALIPA UNDER GE (A), BARMER.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Lump sum price worked out by the contractor for "BUILDING WORKS" as listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of Rs 1640000.00 prepriced by the MES B/F from Sl page No. 30.\n 1 LUMP \nSUM
2 2 Lump sum price worked out by the contractor for "SITE CLEARANCE & EXCAVATION & EARTH WORK" as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of Rs. 1415328.50 prepriced by the MES B/F from Sl page No. 32.\n 1 LUMP \nSUM
3 3 Lump sum price worked out by the contractor for "INTERNAL WATER SUPPLY " as listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of Rs. 6706.00 prepriced by the MES B/F from Sl page No. 33.\n 1 LUMP \nSUM
4 4 Lump sum price worked out by the contractor for "INTERNAL ELECTRIFICATION" as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of Rs.10,000.00 prepriced by the MES B/F from Sl page No. 36.\n\n 1 LUMP \nSUM
5 5 Lump sum price worked out by the contractor for "ROAD, CULVERT, FOOTPATH & HARD STANDING" as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of Rs. 7117544.01 prepriced by the MES B/F from Sl page No. 39.\n 1 LUMP \nSUM
6 6 Lump sum price worked out by the contractor for "SEWAGE DISPOSAL" as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of Rs. 42683.00 prepriced by the MES B/F from Sl page No. 41.\n 1 LUMP \nSUM
7 7 Lump sum price worked out by the contractor for "AREA DRAINAGE" as listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of Rs. 961055.70 prepriced by the MES B/F from Sl page No.42.\n 1 LUMP \nSUM
8 8 Lump sum price worked out by the contractor for "SECURITY WALL/FENCING& GATE" as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of Rs. 1547495.00 prepriced by the MES B/F from Sl page No.43.\n 1 LUMP \nSUM
9 9 Lump sum price worked out by the contractor for "EXTERNAL WATER SUPPLY" as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of Rs. 1624920.00 prepriced by the MES B/F from Sl page No. 46.\n 1 LUMP \nSUM
10 10 Lump sum price worked out by the contractor for "EXTERNAL ELECTRIFICATION" as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of Rs. 6431960.00 prepriced by the MES B/F from Sl page No.47.\n 1 LUMP \nSUM
11 11 Sch 'A' Sec-XI (MISCELLANEOUS ITEMS) \nNotes: \n(i) This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under column 5 signifies this fact only. \n(ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under respective schedule.
12 12 INTERNAL ELECTRIFICATION:\nSupply and fix LED lamp 9 Watt including lamp holder all as specified and directed by Engineer-in-charge.complete all as specified and directed. \n 1 EACH
13 13 Supply and fix LED lamp 12 Watt including lamp holder all as specified and directed by Engineer-in-charge.complete all as specified and directed. 1 EACH
14 14 S & F decorative box type LED tube light fitting 1x20 watt including LED tubular lamp with IP20 protection, inbuilt driver etc complete with all accessories internally pre-wired including connecting up with twin core twisted flexible copper conductor cable of 1.0 sq. mm size complete all as specified and directed. 5 EACH
15 15 S&F heavy duty, exhaust fans of 300 mm sweep suitable for SP 230/250 v 50 Hz AC supply complete with louver shutters including fixing/grouting of frame in wall and cutting opening complete and connecting with and including 3 Nos 1.5 Sqmm single core, PVC insulated but unsheathed FRLS cable with multistranded copper conductors from ceiling rose to fan complete all as specified and directed. 1 EACH
16 16 Supply and fixing ceiling fans 1400mm sweep energy efficient five star rated incl down rods and connecting up with 3 runs of 1.5 sq mm, single core PVC insulated but unsheathed, FRLS cable with multistranded copper conductors IS 694 marked, from ceiling rose to fan complete all as specified and directed. 2 EACH
17 17 S & F MCB, SP 6 to 32 Amp,240 volts, 10 kA, "C" Series curve complete all as specified and directed. 6 EACH
18 18 S & F MCB, SPN 20 Amp,240 volts, 10 kA, confirming to IS 132032 complete all as specified and directed. 1 EACH
19 19 Supply and install wall mounted star rated hi wall split units Indoor/Out door complete with cordless remote control unit and with in built air ionizer and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 1.5 TR all as specified and directed. 2 EACH
20 20 Supply and draw sub main wiring in repairs of two run 6.0 sqmm single core PVC insulated, unsheathed multi stranded copper conductor cable 1100 Volt grade, draw through and including PVC conduit medium duty and accessories of 25 mm size and fixed with PVC saddles and cadmium plated steel screws to the surfaces of the wall/ceiling including one run of 6 sqmm single core PVC insulated unsheathed copper earth continuity conductor all as specified and as directed. (Note : Two runs of single core cable with one run of earth continuity conductor including PVC conduit accessories shall be measured and paid as one length. 31 RM
21 21 Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 v to 250 v with output voltage stabilized at 230 volt with accuracy of +-2.5% and of capacity 5.0 KVA all as specified and directed. 2 EACH
22 22 Supply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase having approx storage and nominal cooling capacity 60/120 complete all as specified and directed. 1 EACH
23 23 Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and directed. 2 EACH
24 24 S & F 1x30 w LED Security light fitting with pressure die cast aluminium housing, heat resistance glass, IP 65 protection complete and including connecting up with twin core twisted flexible copper conductor cable with suitable size including GI tubing 40mm dia light grade 1.5m long band to shape for mounting of security light with 2 nos MS clamps with nut bolts etc complete all as specified and directed. 2 EACH
25 25 ROAD, FOOTPATH AND CULVERT: M&L for marking of centre line, side line etc as per IRC pattern with 2 mm thick thermoplastic road marking compound of approved quality using 8% mica of white/yellow colour (colour as approved by Engineer-in charge ) on bituminous/concrete road surface of temperature 160 degree celcious with a special applicator machine complete as directed by Engineer-in charge including cleaning the surfaces of all loose dirt, dust and other foreign matter, demarcation at site and managing the traffic control etc complete. 90 SQM
26 26 S & F Smart solar Aluminium metalic road studs of size 125 x 125mm and 20mm thick and 55 mm long 40mm dia stand with 6 Nos diode bulbs (3 Nos each side) electronically operated and designed to operate automatically in the darnkness, powered from rechargeable nickel cadmium battery to be charged through solar cells, main frame cast aluminium with polycarbonate cover solar cells and yellow refelctive polycarbonate cover on side complete all as approved by Engineer-in-charge. Make: Road Star, SNI, ace polymers,fire equipment engineers, dish steel fab or similar product manufacturing companies. 20 EACH
27 27 S&F Aluminium metalic Cat Eye 100mm X 100mm X 18.5mm size dynamically designed very high impact strength and fitted with 2 Nos highly reflective reflectors complete all as specified and directed by Engineer-in-charge. 90 EACH
28 28 M & L for identification sign/cautionary mandatory and information sign board area exceeding 2.0 Sqm but not exceeding 4.50 Sqm with 2mm thick aluminium composite panel covered by encapsulated lens type retro reflective sheet (grade 3 m type II dimond grade) on both side with green base, fixed on and including stainless steel frame of size 25mmx25mm and hang on 50mm dia stainless steel pipe (fabrication work from SS 304 material) of height 2.4 metre from ground level to top and post embed in ground with PCC 1:3:6 type C-2 using 40mm graded stone aggregate of size 45cm x45cmx 45cm including necessary excavation and earth work and making plate form of size 150cm x 45cm x 30cm with PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) solid block set and jointed in cement mortar 1:6 and covered with all exposed surfaces with black colour glazed ceramic tiles (joint less) of size 350x350x7/450x300x7mm thick over and including 10mm thick backing coat in cement mortar 1:4, set and jointed in neat cement slurry and pointed to match the tiles complete.\nNote:- (a) The specimen of board is enclosed as Sketch A-1 to A-4, (b) The letters and symbols etc on both side shall be as per site requirement and as approved by User’s & (c) The size and font of wording as per direction of Engineer-in-Charge. 1 EACH
29 29 M & L for identification sign/cautionary mandatory and information sign board area exceeding 0.6 Sqm but not exceeding 0.90 Sqm with 2mm thick aluminium composite panel covered by encapsulated lens type retro reflective sheet (grade 3 m type II dimond grade) on both side with green base, fixed on and including stainless steel frame of size 25mmx25mm and hang on 50mm dia stainless steel pipe (fabrication work from SS 304 material) of height 2.4 metre from ground level to top and post embed in ground with PCC 1:3:6 type C-2 using 40mm graded stone aggregate of size 45cm x45cmx 45cm including necessary excavation and earth work and making plate form of size 150cm x 45cm x 30cm with PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) solid block set and jointed in cement mortar 1:6 and covered with all exposed surfaces with black colour glazed ceramic tiles (joint less) of size 350x350x7/450x300x7mm thick over and including 10mm thick backing coat in cement mortar 1:4, set and jointed in neat cement slurry and pointed to match the tiles complete.\nNote:- (a) The specimen of board is enclosed as Sketch A-1 to A-4, (b) The letters and symbols etc on both side shall be as per site requirement and as approved by User’s & (c) The size and font of wording as per direction of Engineer-in-Charge. 1 EACH JOB
30 30 SEWAGE DISPOSAL:\nConstruction of 5 users Hume Pipe septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft,connection etc., complete all as specified and as directed. 1 EACH JOB
31 31 Construction of 1.2 M dia X 3 M effective depth Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonry in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size incl rfr & removal complete all as specified and as directed.\nNote:- Effective depth of Sockage wells to be considered from bottom of outlet pipe of septic tank. 1 EACH JOB
32 32 EXTERNAL ELECTRIFICATION:\nXLPE insulated, screened, PVC bedded,galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 33000 volts, grade cross sectional area 120 sq. mm.complete all as specified & directed. 200 RM
33 33 S/F Pin type, porcelain, vitreous brown insulator including one galvanised mild steel spindle , two galvanised iron nut, 140 mm dia and 240 mm high 33000 volts grade all as specified and as directed. 600 EACH
34 34 S & F Disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green: Single assembly for tension with tension clamps for conductors,working pressure 33 000 volts complete all as specified & directed. 69 EACH
35 35 Supply and fix cable jointing kit for 33 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 120 sq. mm 3.0 core XLPE electric cable complete all as specified & directed. 8 Each
36 36 Motorized Auguring/drilling in road at 90cm depth of dia suitable for laying of 80/100mm dia GI tubing pipe complete all as specified and directed.\n 25 RM
37 37 Supply & fix switch air break gang operated triple pole mechanically operated mounted on insulator (09 insulators)& steel frame with operating mechanism including spring loaded mechanism set of three working from ground level, 33000 volt including locking arrangement of Current rating 200 Amps suitable for 33 KV, (Horizontal type) complete all as specified and directed by Engineer-in-charge. 4 EACH\nJOB
38 38 Supply and Fix Lithium Based Engergy efficient Integrated Solar Street Light - 24W in single FRP body encase solar PV panel 53/55Wp monocrystalline, lithium battery 11.1/12.8 V, 28.6AH with inbuilt BMS, high brightness W- LED (180lm/Watt) lamp, CRI > 70, color temperature 6500K , microcontroller based charge controller cum driver, automatic dimming function with PIR motion sensor, dusk to Down operation, LUX output 20-25 (from 8-9 mtr height), working temperature (-) 10C to (+) 55oC. weight : 14 -16 kg, with adjustable MS clamp suitable for pole/wall mounting. Protections : short circuit, overload , reverse polarity and battery protections. Firm should produce vital parameters test report from NABL accredited lab and should be of made in India with CE & ROHS certified and including necessary civil work and incl GI pipe bracket of suitable dia light grade pipe bend to shape of approx length 1.5 mtr incl 2 no MS clamp of flat iron of suitable size complete with nut, bolt , washers complete all as specified and directed by Engineer-in-charge.\nmake:-AXXON TECH,CROMPTON/BAJAJ/PHILIPS 25 EACH
39 39 EXTERNAL WATER SUPPLY:\nM&L for Cast iron foot valve both end flanged class conforming to IS-4030 including necessary nuts bolt, washer, rubber or fiber board gasket complete suitable for 80 mm bore of pipes all as specified and directed. 2 EACH JOB
40 40 Construction of brick masonry valve pit of size 90cm x 90cm X 90 cm (internal dimensions) with one brick thick wall in cement mortar 1:4 on 100mm thick PCC 1:4:8 type D2 ( using 40mm graded broken stone aggregate) as in foundation lean concrete, including PCC 1:3:6 type C-1 ( using 20mm graded crushed stone aggregate) as in benching and coping and 10mm thick cement plaster in CM (1:4) internally and externally upto 15cm below ground level providing valve pit cover 40x40x6mm angle iron frame all-round fixed by means of 4 Nos holdfast 150mm long made out of flat iron 40x6mm embedded in PCC block (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) of size 90x90x90mm incl provn of hinges welded with angle iron frame and MS cover 3mm thick sheet, MS handle of suitable length and size welded with MS cover and suitable locking arrangement and applying two coats of synthetic enamel paint over a coat of red oxide primer including necessary excavation and earth work in soft/ loose soil complete all as shown on drawing and as specified. 5 EACH\nJOB
41 41 Construction of brick masonry valve pit of size 60cm x 60cm X 60 cm (internal dimensions) with one brick thick wall in cement mortar 1:4 on 100mm thick PCC 1:4:8 type D2 ( using 40mm graded broken stone aggregate) as in foundation lean concrete, including PCC 1:3:6 type C-1 ( using 20mm graded crushed stone aggregate) as in benching and coping and 10mm thick cement plaster in CM (1:4) internally and externally upto 15cm below ground level providing valve pit cover 40x40x6mm angle iron frame all-round fixed by means of 4 Nos holdfast 150mm long made out of flat iron 40x6mm embedded in PCC block (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) of size 90x90x90mm incl provn of hinges welded with angle iron frame and MS cover 3mm thick sheet, MS handle of suitable length and size welded with MS cover and suitable locking arrangement and applying two coats of synthetic enamel paint over a coat of red oxide primer including necessary excavation and earth work in soft/ loose soil complete all as shown on drawing and as specified. 5 EACH\nJOB
42 42 Supply,install, commission and testing cubical type LT panel board outdoor , manufactured by a CPRI approved factory, floor mounted, dust & vermin proof,front and rear operated door with necessary locking arrangement made of 50 x 6mm MS angle iron frame work and CRCA sheet of 3.15 mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with suitable capacity copper bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and directed with the following accessories :- INCOMING\n(a) MCCB 4 pole, 415 Volts, 125 Amps, 25 KA - 01 No.\nOUTGOING\n(a) MCCB 4 pole, 415 Volts, 63 Amps,16 KA -02Nos (b) automatic star delta staters suitable for 5 HP motors complete with single phase preventor- 02 Nos (c) MCB SPN , 220 Volts, 20 Amps,10 KA -02 Nos (Spare-01 nos) \n(d) Digital Multi functional meter (Ammeter, Volt Meter,PF and Frequency ) - 01 No.\n(e) Indicator lamp (RYB) (set of three) - 01 Set\n 1 EACH\n
43 43 Supply installed testing and commisioning Induction Motors of capacity 5 HP along with suitable pump with discharge range 300 LMP ± 10%, at a head not less than 20 mtrs complete, Horizontal Foot Mounted Induction Motor suitable for 415V ± 10%, 3 Phase, 50 Hz ± 5%, Insulation Class ‘F’, Degree of protection IP 55, Ambient of 50°C conforming to IS 12615:2011, IEC 60034-30-2008.complete all as specified and directed by Engineer-in-charge. 2 EACH\nJOB
44 44 Supply and spreading clean dry sand in trenches for cushioning all as specified for cable protection complete all as directed, complete all as specified and directed by Engineer-in-charge. 38 CUM
45 45 SOLAR POWER PLANT :-
46 46 Supply, install, testing, design and commissioning of Solar PV modules to meet cumulative rated capacity of 2 MWp at STOC. Modules will be of Poly Crystalline type with 72 cells and minimum rating of 315 Wp with positive tolerance, with minimum 1100 mm cable length. Module efficincy >15.8%, fill factor>0.7, performance ratio more than or equivalent to 75%,module will be free of PID, module connector suitable for MC4/Bizlink and jucntion box with minmimum IP 67 rating. Module NOCT will be 45±°C with temperature coefficient of power <0.4%/°C, and will be suitable for operation from -20°C to +60°C ambient temperature. Modules will be combined to make array & string of panels to maximize power output along with supply and installation of necessary accessories like fuses, array/string junction box etc., Modules will be certified for relevant dust standards (Applicable standard would be IEC 60068-2-68). Modules shall be deployed with RF id tag inside lamination as per MNRE guidelines. Guranteed electrical degradation of power generated not exceeding 20% of the minimum rated power over the 25 year period and not more than 10% after ten years period of the full rated original output. Warranty against manufacturing defect, raw material, workmanship, inspection and testing procedures shall be 5 years from the date of commissioning. Modules shall be certified as per IEC 61215-Edition -II, IEC 61646 and IEC 61730-1 & 2 and other applicable IEC/IS standards. It shall perform satisfactorily in relative humidity 85 ± 5%l) and should withstand wind 170 KPH on the surface of the panel. 6500 EACH JOB
47 46.01 (i) Each module shall have RFID tag encapsulated with Solar Cells bearing the following details. RFID reader will be provided by contractor.\n ? Name of manufacturer of PV module\n ? Name of manufacturer of solar Cell\n ? Month and year of manufacture (Separated for cell & module)\n ? Country of origin (separately for solar cell & module)\n ? Peak wattage, Im, Vm and fill factor of the module.\n ? Date of year of obtaining IEC PV module qualification certificate including the test lab issuing IEC certificate.\n ? Unique Serial No and model No of Module. \n ? I-V curve of Module\n(ii) The temperature co-efficient for the module shall not be more than 0.50%/°C.(iii) Every module must have by pass diode of suitable capacity.(iv) PV module must conform to latest edition of IEC 61215/IS14286. In addition, the modules must conform to IEC 61730 Part-I & II for construction and testing & safety qualification & conforming to IEC 62804 PID.(v) It shall also in conformity of latst minimum technical specifications issued by MNRE from time to time. (vi) Provision of earthing & earth strip/cables etc. for earth for solar PV module/Array etc. as per latest IS/MNRE norms to be provided and the cost of the same is to be included in this item and no extra amount will be paid to the contractor on this account. (vii) RFID reader to be provided by contractor. \nNOTE:- 1. All mechanical structures/items ,electrical items and SPV power system for solar power plant must be warranted for a Minimum of 5 years.\n 2.All PV cells and modules used in solar plants setups will be made in India. PV modules are of 72 cells and polycrystalline as per technical specification issued by MNRE.\n3.Modules should be of MNRE empanelled manufacturer of highest rating/grading (Tier-1/catagory 1). \n4.Testing of PV modules at factory premises shall be carried out in presence of Rep of Accepting officer to be nominated by the Accepting officer before the execution of this item. \n5. Contractor shall intimate the engineer in charge in writting at least 15 days in advance before dispatch of the order of PV modules.\n6.The Solar power plant should be designed by MNRE channel partner and duly vetted by Engineer in Charge.
48 47 Module Mounting Structure: Supply ,fabricate and erection of mould mounting type structure hot dip galvanisied mild steel with coating not less than 85 Microns and suitable to wind load 170 KMPH and electrolytically compatible channels,bracing perlins Size as per IS code Design, electromagnite washers nut , bolt inclduing cutting drilling etc. The design shouble be as per relevent latest IS-2061 and galvanizing as per IS-4759. It should be suitable for the wind speed, sun light and climate condition of the plant location. The design life should be more than 25 years and minimum yield strength of 340 MPA. Module Ground Clearance shall be 500mm ± 100mm. Properties of RHS will conform to IS 4923:1997. HDG Fasteners of 4.6 grade and 8.8 grade for Structure.The Module Mounting Structure to be of Manual Seasonal tilt of 0 degree to 45 degree to provide maximum generation.The structure should be suitable for easy removing and refixing of PV modules of the solar plant all as specified and as directed by Engr-in-Charge.\nNOTE:- foundation shall be paid seperatly as per relevent item no.75 of BOQ\n\n 100000 KG
49 48 Design, Supply, installation, testing and commissioning of grid tied 3 phase string inverter outdoor type of with minimum IP 65 rating, with minimum 60 kW AC output at 50°C ambient temperature. Minimum European efficiency of the inverter shall be 98% load as per IEC 61683 standard for measuring efficiency. Maximum DC input voltage shall be 1000 V and inverter supplied shall have upto 10% additional DC input capacity. (Array to Inverter Ratio 1:1), 3 phase AC Nominal Output voltage 415 V (with ±10% range ), Frequency 50Hz (±10% range), PF at rated output capacity: 1 (with range from 0.8 lag to 0.8 lead), Total ITHD: < 3%, Operating temperature range : - 20°C to + 60°C. All inverters should consist of associated control, protection and data logging devices and remote monitoring hardware and compatible with software used for string level monitoring.all as specified and as directed (maximum Quantity - 34 Nos., no. of inverters can be reduced with higher rated capacity inverters, accordingly DC/AC cables, SCBs and AC PDBs quantity/capacity to be modified). Other important features/ protection required in the inverter are as under:- \n 34 EACH JOB
50 48.01 (i) Automatic morning wake-up and nightly shutdown. (ii) Mains (Grid ) over-under voltage and frequency protection. (iii) Galvanic isolation and fool proof protection against ISLANDING . (iv) Included authentic tracking of the solar arrays maximum power operation voltage (MPPT). (v) Array ground fault detection. (vi) LCD and Piezoelectric keypad operator interface Menu driven. (vii) Automatic fault condtions reset for all parameter like voltage, frequency and /or black out. (viii) MOV type surge arrester on AC and DC terminals for over voltage ptotection from lightning -induced surges. (ix) Provision for input and output isolation. (x) Inverter shall be installed on GI stand made by the angle size 50mm x 50mm x 6mm. Structure burried in ground and shall be 450mm above ground level.\nGrid Connectivity: Relevant CERC/RERC regulations and grid code as amended and revised from time to time shall be complied. Inverter shall adjust the voltage & frequency levels to suit the Grid.complete all as specified and directed.\nNOTE:-\n1.Testing of inverter at factory premises shall be carried out in the presence of Rep of Accepting officer to be nominated by the Accepting officer before the execution of this item. \n2. Contractor shall intimate the engineer in charge in writting at least 15 days in advance before dispatch of the order of inverter.
51 49 Supply and installation of branch, MC4 Male/Female connectors set compatible with module connectors with min of IP66 rating and design with suitable lugs for 6 Sqmm Cable complete all as specified and directed. 1600 EACH JOB
52 50 Design, Supply, install, laying with PVC conduits, lugs, nails, cable ties, termination etc., testing and commissioning of annealed single copper DC String cable of 1C x 6 Sqmm Solar grade, UV resistant 1.5 kV rated DC Cables with elctron beam XLPO insultaion confirming to IEC IEC 60754-1 & IEC 60754-2, IEC 60332-1, IEC 60332-3-24., IEC 61034. Temperature range -40 to +1200 C complete all as specified and directed. Average energy loss in DC cabling shall be <1.5% from solar panel to inverter. complete all as specified and directed. 25000 RM
53 51 Design, Supply, install, laying with conduits, lugs, nails, cable ties, termination etc., testing and commissioning of PVC insultated copper cable of 1C x 6 Sqmm for earthing confirming to IEC and IS standards. complete all as specified and directed. 7500 RM
54 52 Design, Supply, install, laying with PVC conduits, lugs, nails, cable ties, termination etc., testing and commissioning of AC copper cable of 4C x 16 Sqmm from inverters to AC panels as per inverter and panel design, UV resistant 1.1 kV rated, PVC/XLPE insultaion confirming to IEC and IS standards. Temperature range -40 to +1200 C.complete all as specified and directed. 6500 RM
55 53 Desing, Supply, laying in duct/trenches/pipe with necessay lugs, cable termination kits, testing and installation of power cable from AC panel to main LT panel of XLPE insulated 3.5C x 300 sq mm, 1.1kV Aluminium Armoured LT cable as per relevant IS complete all as specified and directed. 1200 RM
56 54 Desing, Supply, laying in duct/trenches/pipe with necessay lugs, cable termination, testing and installation of power cable from main LT panel to transformer of XLPE insulated 1C x 300 sq mm, 1.1kV Aluminium Armoured LT cable as per relevant IS complete all as specified and directed. 400 RM
57 55 Supply, install, testing and commissioning of Data monitoring system communication cable RS 485 [screen twisted] complete all as specified and directed. 3500 RM
58 56 Supply, install, testing and commissioning of Inverter communication Shielded CAT6 cables complete all as specified and directed. 600 RM
59 57 Supply, installation, testing and comissioning of weather and vermin proof outdoor type LT Panel factory made, front & back openable, double door type, CPRI approved fabricated out of 3.15 mm thick CRCA (Cold Rolled Closed Annealed Cell) sheet compartmentalized design not less than 1.8m x 1.6m x 0.75m including mild steel channel frame of ISMC 75 at the base of panel only for grouting purpose, and grouted in M-20grade concrete(Design Mix) using 20 mm graded stone aggregate, duly epoxy powder coated, complete with heat shrink insulated aluminium bus bar of 1200 Amps rating 4 Nos, including all connections with aluminium strips. Pillar box shall be provided with danger notice plate with skull & bone sign, PVC gasketed and sealed, making all incoming and out going electrical cable connecetions with new lugs, glands to be provided at cable entries, including angle iron support 50x50x6 mm with 50 CM height from ground level at the base of panel complete all as specified and as directed (Qty-10 Nos). Each panel shall be comprising of following accessories:- \nINCOMING: - (a) MCCB, TPN 415 Volts, 50Hz, 125 Amps, 16 KA, thermal magnetic release, Ics =100% Icu, front face isolataion with positive break indication with double break contacts with spreader and phase barrier - 04 Each\n(b) Volt meter 0-500 V digital type with selector switches - 01 Nos.\n(c) Multi function digital energy meter with RS 485 communication port with CTs .\n(d) Phase Indicator lamp assy RYB - 01 Set.\n 10 EACH JOB
60 58 Supply, installation, testing and comissioning of weather and vermin proof outdoor type LT Panel factory made, front & back openable double door type, CPRI approved, fabricated out of 3.15 mm thick CRCA sheet compartmentalized design not less than 1.8m x 1.6m x 0.75m including mild steel channel frame of ISMC 75 at the base of panel only for grouting purpose, and grouted in M-20 grade concrete(Design Mix) using 20 mm graded stone aggregate, duly epoxy powder coated, complete with heat shrink insulated aluminium bus bar of 2500 Amps rating 4 Nos, including all connections with aluminium strips, Pillar box shall be provided with danger notice plate with skull & bone sign, PVC gasketed and sealed, making all incoming and out going electrical cable connecetions with new lugs, glands to be provided at cable entries, including angle iron support 50x50x6 mm with 50 CM height from ground level at the base of panel complete all as specified and as directed. The panel shall be comprising of following accessories:-\nINCOMING: - (a) LT Air Circuit Breaker with ACB 630 Amps. 50 KA 4 pole, 415 volts, 50 Hz for rated current at ambient temperature 50°C and conforming to IS-13947 (Part 3, 1993) and IEC : 60947 (Part 1 & 2) and other technical features as per SSR Part-I 19.100.13 with manual operated draw out type Icu=Ics (1 sec) with microprocessor release 6L (over load, short circuit, instantaneous and earth fault protection), pre trip alarm and individual fault indication LED with fully rated neutral with inbuilt protection. The over load release shall be adjustable type and ACB shall have zone selective interlocking fault signaling contact. 2 EACH JOB
61 59 Design, supply, installation, testing and comissioning of copper wound inverter duty step of transformer of 1.2 MVA, 0.4/33 kV with standard fittings and accessories such as conservator, protection relays, instrumentation as per applicable IEC/IS standards. No Load Losses shall be = 0.15% of rated capacity and Full Load Losses = 1.1% of rated capacity. LV rated voltage: as per inverter output, HV voltage range: 33 kV±10% with 2.5% steps of OLTC tap changer . Cooling: ONAN, Imepedence: As per inverter manufacturer recommendatio/IS standard. Installation: Outdoor, Temperature Rise above ambient of 50 deg C: for Oil- 50 Deg for Winding:- 55 deg C, Fault Level at terminals: MV Side (25kA for 2 sec), LV Side (35kA for 2 sec), Creepage at MV Side: 25mm/ kV. Necessary civil foundation and structure with fencing to be provided. \n \n 2 EACH JOB
62 59.01 Note :- i) First fill of oil as per manufacturer instructions shall deemed to be included in the unit rate quoted by contractor. \nii)- Plinth for transformer including stone metal aggregate around transformer plinth with and including slant slot for accomodating 100 mm dia pipe on both LT & HT side with clamping arrangement of size and specifications as per manufacturer instructions, shown on drawings and as directed by the Engineer-in-charge complete shall deemed to be included in the unit rate quoted by contractor
63 60 Supply, install, testing and commissioning of air natural 2 winding aux power transformer of 50 kVA, Inverter rated voltage/0.415 kV DNy11 Transformer,complete all as specified and directed. 1 EACH JOB
64 61 Supply, installation, testing and commissioning of 36 kV rated, 630 Amps, 20 KA for 3 Sec HT vacuum circuit breaker panel at transformer outgoing conforming to IEC 62271-200, 25 KA for 1 Sec, LSC2B-PM class front accessed comprising of Indoor Vacuum Circuit Breaker as incomer consisting of the following:-\n(a) 630A continuous rated electrolytic copper bus bar, droppers and bus bars should be insulated with full system voltage sleeves (b) Trolly mounted horizontal racking in rack out and horizontal isolation, vacuum circuit breaker as per IEC 62271-100 so that the breaker rack in /out is done in a smooth manner. Vacuum circuit breaker should have three no resin encapsulated/ segregated vacuum bottles of the same manufacturer as of circuit breaker. The Vacuum Bottle should be type tested for 100 full short circuit operations. (c) Motorized spring charging mechanism with integral spring charging handle for manual spring charge. (d) Inter panel epoxy barrier to restrict arc propagation from one panel to another. (e) Cast resin Current Transformer 33 kV, 200-100/5A, core 1: class 0.5, 15 VA, Core 2: 5P10, 15 VA with metering and protection core including necessary control wiring. 2 EACH JOB
65 61.01 (f) Accessories like local remote switch, breaker control switch (T-N-C), space heater with thermostat, DC & AC control circuit through MCB, indicating lamps for RYB, spring charge, DC supply healthy, breaker ON/OFF, breaker in SERVICE/TEST. (g) Multifunction meter with RS 485 port (h) Digital Ammeter and Digital Volt meter (j) Separate master trip Relay and anti pumping relay. (k) Comprehensive numerical protecting relay should have built-in interagted mimic compatible with IEC 6185 for directional and non directional O/C, E/F, U/V, O/V protection type having following additional facilities :- (i) Trip ckt supervision. (ii) Distribution recorder. (iii) Event log with date and time. (iv) Conformal coating for harsh environment. (v) Suitable to operate on 24 volts DC for auxiliary and control supply. (vi) Aux. Relay for Alarm & Trip - 3 Nos. (l) Panel should also have additional facilities :-\n(i) Continuous rated closing coil. (ii) Fully integral arc type tested (20 KA for 1 Sec) as per latest IEC 62271-200. (iii) Vacuum bottles should be tested for 100 full short circuit operations.. (iv) Manual closing/ tripping of CB with compartment door closed. (v) The panel shall be provided with power pack battery back up for not less than 30 minutes. (vi) The Height of the HT section should atleast be of 1400mm for human safety during the internal arc creation. (vii) Breaker shall be provided with following contacts. (a) Auxiliary switch with 6NO+NC mounted on the draw out portion of the switchgear. (b) Position switches with 3 NO+1NC contacts for each position in SERVICE and TEST. The panel shall be SCADA Compatible system.
66 62 Design, Supply, install, testing and commissioning of Solar Observatory system or Weather Station complete all as specified and directed consisting of following:-\n1. Pyranometers: 1\n2. Rain Guage: 1\n3. Module Temp Sensor: 4\n4. Ultrasonic Anemometer: 1\n5. Temp & relative Humidity Meter: 1\n6. Solar Panel (35 W) + Battery Bank: 1\n7. Data Logger: 1\nNote : All data shall be recorded chronologically date wise. The data file shall be MS Excel compatible. The data logger shall have internal reliable battery backup to record all sorts of data simultaneously round the clock. All data shall be stored in a common work sheet chronologically. Representation of monitored data shall be in graphics mode and/or in tabulation form. All instantaneous data can be shown in the Computer Screen. 1 EACH JOB
67 63 Design, supply, installation, testing and commissioning of on grid Data Acquistition/Plant monitoring system (SCADA)suitable for 3 Phase, 415V, 50Hz, AC power string inverter with all protection & controlling as per specifications complete etc as per requirement with an overall efficiency of not less than 98% (with inbuilt or external data logging device & on line portal log-in ID & password) & one PC with intel i5 processor, 2TB HDD, 4GB RAM, 19'' LED monitor, preloaded with Window10 & MS Office, one all-in-one printer suitable for A-4 size papers (black and white). The following parameters (i) to (xxiii) should be accessible via operating interface display in real time separately for solar power plant. i. AC Voltage ii. AC Out put current iii. Output power iv. Power factor v. DC Input Voltage vi. DC Input Current vii. Time Active viii Time Disabled ix. Time Idle x. Power produced xi. Protective function limits (viz-AC Over Voltage, AC Under voltage, Over frequency) 1 EACH JOB
68 63.01 xii. All major parameters available on the digital bus and logging facility for energy auditing through the internal microprocessor and read on the digital front panel at any time and logging facility (the current values, previous values for up to a month and the average values) should be made available for energy auditing thourgh the internal microprocessor & should be read on the digital front panel. xiii. PV array energy production: Digital Energy Meters to log the actual value of AC/DC voltage, Current and Energy gererated by the PV system provided. Energy meter along wiht CT/PT should be of 0.5 accuracy class. xiv. Computerized DC String/ Array monitoring and AC output monitoring shall be provided as part of the inverter and/or monitoring shall be provided as part of the inverter and /or string/array combiner box or separately.
69 64 Design, Supply, install, testing and commissioning of Main distribution board Floor Mounted PDB with 1 x 63A, four pole main incomer with energy meter, indication lamps complete all as specified and directed with and including following outgoings :-\n(a) 1 x 25A TPN MCB\n(b) 2 x 63A TPN MCB\n(c) 4 x 10A TPN MCB\n(d) 4 x 6A DP MCB\ncomplete all as specified and directed. 1 EACH JOB
70 65 Design, Supply, install, testing and commissioning of 5 kVA UPS with battery bank for 60 minutes backup at 100 % load as per design & specifications for Solar System critical components, Industrial type Onine UPS with static switches for bypass . complete all as specified and directed. 2 EACH JOB
71 66 Design, Supply, install, testing and commissioning of UPS distribution board of Floor Mounted UPS DB, indication lamp as per site conditions.\n(a) 1 x 32 A DP MCB with 100mA ELCB main incomer with energy meter\n(b) 4 x 10A DP MCB\n(c) 4 x 6A SPN MCB\ncomplete all as specified and directed. 2 EACH JOB
72 67 Earthing with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick, burried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized 32x6mm earth strip by means of bolts, nuts check nuts and washers of galvanized iron or steel with protection pipe of GI, light grade 40mm bore, watering pipe 20mm bore of GI medium grade, earth plate surrounded by alternate layer of coal dust and common salt 15 cm thick each layer all as per electrical plate No 3 of SSR Part-I and connected to earthing test point all as specified or indicated and testing on completion including funnel with wire mesh, earthing chamber with PCC (1:2:4) type B-1 using 20mm graded stone aggregate, 80 mm thick precast RCC 1:1.5:3 type A-1 cover duly reinforced with XPM (weight not less than 3 kg/sqm) and frame including all excavation and earth work etc. all as specified. \nNote : 1. Earth chamber shall be constructed at least 1.50 metre away from the top of earth electrode, the earth pit and pipe for watering shall be provided in slanting manner. \n2. Cost of 7.5m length of GI strip & GI protection pipe included in the rate of this item. \n3. The double earthing of structure, inverter and LA will be provided through a bus arrangement from their respective earth pits. \ncomplete all as specified and directed. 40 EACH JOB
73 68 Earthing with copper earth plate 600mm x 600mm x 3.15mm thick, burried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to copper earth strip 20x3mm by means of bolts, nuts check nuts and washers of galvanized iron or steel with protection pipe of GI, light grade 40mm bore, watering pipe 20mm bore of GI medium grade, earth plate surrounded by alternate layer of coal dust and common salt 15 cm thick each layer all as per electrical plate No 3 of SSR Part-I and connected to earthing test point all as specified or indicated and testing on completion including funnel with wire mesh, earthing chamber with PCC 1:2:4 type B-1 using 20mm graded stone aggregate, 80 mm thick precast RCC (1:1.5:3) type A-1 cover duly reinforced with XPM (weight not less than 3 kg/sqm) and frame including all excavation and earth work etc. all as specified. \nNote : 1. Earth chamber shall be constructed at least 1.50 metre away from the top of earth electrode, the earth pit and pipe for watering shall be provided in slanting manner. \n2. Cost of 7.5m length of copper strip & GI protection pipe included in the rate of this item. Extra length shall be measured and paid separately. \n3. Earth pits for body earth of transformer, 2 earth pits for neutral earthing, 2 earth pits for body earthing of LT and HT panels in a bus form) complete all as specified and directed. 20 EACH JOB
74 69 Design, supply, install, testing and commissioning of lightening protection system of Early Streamer Emission type Lightning Spike with GI mast of 8.5 Mtrs alongwith all mounting structures & civil work as per applicable IS/IEC standards. complete all as specified and directed. 40 EACH JOB
75 70 Supply and fixing of fire fighting automation and signboards in buildings, foam type and CO2 fire extinguisher. Supply of LT (1.1kV) Rubber Mat, MV (33kV) Rubber Mat, discharge rods, Sand bucket with stand, 33kV Hand Gloves, First Aid Box and Shock Treatment Chart.complete all as specified and directed. 1 Each Lot
76 71 All necessary permissions/ laisoning for evacuating the 02 MWp solar power Expenditure to be incurred with the existing 33/11 kV consumer substations located in Central power house system from appropriate authorties as directed by GE . This shall include necessary infrastructure including metering arrangement for import/export consumption and ABT metering arrangement at DISCOM substaton with CTs &PTs metering cubicle and check meter etc. harmonic stabilization within the limits of Central Electrical Authority (CEA) and necessary statutory approvals from DISCOM/RERC and various other state agencies as required. The rate/amount quoted against this item shall deemed to be inclusive of this aspect and no claim whatsoever shall be entertained at later stage Note-This item include the registration of 2 MW SPV works with RREC all concerned documentation in consulttation with department.\nNote:- Any security deposit/ Fees payble to JdVVNL/RSEB for registration to obtain permission will be borne by the MES. 1 Each Job
77 72 Design, Supply, laying, testing and commissioning of 20 mm X 3 mm flat copper earthing strip as per applicable standards. 320 RM
78 73 Design, Supply, laying, testing and commissioning of 32mm X 6 mm GI earth strip as per applicable standards. 320 RM
79 74 M&L for borewell earthing upto 50 mtrs depth with heavy duty GI 50 mm dia provided with holes at regular internal of 20 mm distance with casing pipe 150 mm dia GI light grade upto 12 Mtrs length,GI 50 mm dia heavy duty pipe to be connected to GI earth strip 32x6mm by means of bolts,nuts and washer of galvanised iron or steel . Bore filled with coal dust and common salt and connected to earthint test point all as specified. Earthing chamber with PCC 1:2:4 type B-1 using 20 mm graded stone aggregate.Cost of 7.5M length of copper strip and GI protection pipe included in the rates of this item. Extra length shall be measured and paid saperately. 6 Each Job
80 75 PROVISIONAL LUMP SUM Provide Provisional Lumpsum of Rs.40,00,000 (forty lakh ) for:- \n (a) To provide foundations and fixing of modular mounting structure (b) To provide all fixing arrangement for fixing of modular mounting structure with foundations. \nNote: (i) Provisional lump sum shall be expended wholly or in parts as directed by GE. The works under Provisional Lumpsum shall be measured and paid for at applicable rates in MES SSR Part-II subject to percentage (+ or - denomination) computed under last column of this schedule above/below the provisional lump sum price worked out by the MES . T ype of Foundation as per Design including excavation,shuttering and for column , RCC M-30 , reinforcement , required form work, MS plate grouted in RCC with and including MS Bolts, nuts, washers etc., complete all as specified and as direceted. \n\nNOTE:- Percentage worked out over/under MES lump sum amount shall prevail over contractors quoted lump sum. \n 1 PROVISIONAL LUMP SUM
81 76 Annual maintenance & operation for trouble free operations of 2000KWp Solar Power Plant at Jalipa, Barmer to ensure maximum Solar energy is fed to grid including following:- Trouble free operation of the Solar Power Plant, Servicing of all Solar equipments, HT & LT control system, Transformers weather monitoring equipments , SCADA system etc all as per OEM recomendation,Monitor the Performance of the Solar Power Plant by data logging. Monthly report preparation & reporting to MES on performance of Power Plant, Maintenance of Module – Periodic cleaning of module (Weekly or as required basis ), Scheduled maintenance of Inverter, Attend to the emergency break down of the components, Frequent testing of plant equipment by ‘Walk Down’ checks to internal condition of equipments such as module performance, inverter test, monitorting system testing etc., Careful logging of operation data and periodically processing it to determine abnormal or slowly deteriorating conditions, Careful control and supervision of operation conditions. (Wide and rapid variations in voltage and frequency conditions do contribute to increased maintenance) Regulate routine maintenance work such as keeping equipment clean, cleaning of module, proper maintenance of inverters, Area cleaning removing of grasses, bushes etc as per the instruction of Engineer-in-Charge.& spare parts maintenance for the following months:- \n\nContractor shall provide following manpower for maintenance period :-\n(a) One Engineer ( Minimum Diploma Holder), One trained Electrician ( Minimum ITI in electrical) and Two Helper in first shift (6:00amto 2:00pm) and second shift (2:00pmto 10:00pm) attending/monitoring the breakdown and preventive maintenance.\n(b) One trained Electrician for third shift (10:00pmto 6:00am) .\n(c)Min.04 Nos skilled labour for cleaning the panels (Weekly or as required basis )\nNOTE:\n1. NOTE: Rate quoted against Sl item No 77.01 to 77.06 is to maintain the installations in a presentable manner and always keep in 100 % functionable condition are deemed to be included in the cost of quoted rate and inclusive of cost of replacement of defective parts/equipments . No extra payment will be made to the contractor on this account.’’ \n 2. The Engineer/ Electrician shall submit day to day performance reports in soft / hard copy format as required by the Engineer in Charge.
82 76.01 (a) For FIRST 11 Months 11 month
83 76.02 (b) Next 12 to 22 Months 11 month
84 76.03 (c) Next 23 to 33 Months 11 month
85 76.04 (d) Next 34 to 44 Months 11 month
86 76.05 (e) Next 45 to 55 Months 11 month
87 76.06 (f) Next 56 to 66 Months 11 month
Disclaimer :