Military Engineer Services-MES has published Repair Maintenance Of Summer Appliances And Repair Maintenance Of Summer Appliances And Other Misc Work At Mil Stn Kalka Under Ge Jutogh. Submission Date for this Tender is 09-05-2020. Air Conditioner Tenders in KALKA Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

24060305
Corrigendum : Repair Maintenance Of Summer Appliances And Repair Maintenance Of Summer Appliances And Other Misc Work At Mil Stn Kalka Under Ge Jutogh
National Competitive Bid
Indian
Haryana
KALKA
09-05-2020

Tender Details

Repair Maintenance Of Summer Appliances And Repair Maintenance Of Summer Appliances And Other Misc Work At Mil Stn Kalka Under Ge Jutogh

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 25-Mar-2020 Extension of dates Date 16-04-2020
2 20-Apr-2020 Extension of critical dates Date 09-05-2020

Key Value

Document Fees
INR 300 /-
EMD
INR 10000.0 /-
Tender Value
INR 5 Lakhs /-

BOQ Items

Name of Work: REPAIR MAINTENANCE OF SUMMER APPLIANCES AND OTHER MISC WORK AT MIL STN KALKA UNDER GE JUTOGH.
Sl. No. Item Description Item Code / Make Qty Units
1 1 CEILING FAN
2 1.01 M&L for servicing of ceiling fans, any sweep/size at existing position from various locations for maintenance after removing cable connection from ceiling rose, checking, tightening of thread of down rod, opening of fan, greasing/oiling of bush/ bearing, re-assembling and fixing the same in position including replacement of minor part such as split pin, lock bolt, condensor clamp check nut and cable flexible from ceiling rose to ceiling fan and connection etc including testing for its smooth running complete all as specified and directed.\nNote: Spare parts will be paid separately under respective items 225 Each
3 2 Supply only following component suitable for ceiling fan :-
4 2.01 Ball bearing as per sample suitable for ceiling fan Make: NBC/ SKF. 70 Each
5 2.02 Capacitor of 2.5 Mfd Make: Unistar /EPCOS 400 Each
6 2.03 Gun metal bush as per sample 70 Each
7 2.04 Ceiling fan blade as per sample set of three suitable for 1200mm sweep. 10 Each
8 3 M&L for rewinding of ceiling fan with appropriate gauge size super enameled copper wire including necessary insulation material after cleaning of stator for 1200/1400 mm sweep ceiling fans complete all as specified and directed. 70 Each Job
9 4 Exhaust Fan
10 4.01 M&L for servicing of exhaust fans, any sweep/size at existing position from various location for maintenance after removing cable connection from ceiling rose, checking, tightening of nuts, bolts, opening of fan, greasing/oiling of bearing, re-assembling and fixing the same in position including replacement of minor part such as split pin and cable flexible from ceiling rose to exhaust fan and connection etc including testing for its smooth running complete all as specified and directed.\nNote: Spare parts will be paid separately under respective items 50 Each Job
11 5 Supply only following items for exhaust fan:-
12 5.01 Capacitor 4 Mfd, 230 Volt Make: Unistar/EPCOS. 50 Each
13 5.02 Ball bearing as per sample suitable for exhaust fan Make: NBC/SKF 50 Each
14 5.03 Exhaust fan blade of any sweep with screws/bolts, nuts. 10 Each
15 5.04 Exhaust fan louvers complete with nut & bolts etc. 30 Each
16 6 M&L for rewinding exhaust fan stator with super enameled copper wire of appropriate gauge including necessary insulation material complete varnishing and heating the new winding for proper insulation including cutting the existing winding wire from the stator and cleaning the slot complete all as directed for following sizes:-
17 6.01 300mm sweep 70 Each Job
18 6.02 450 mm sweep 30 Each Job
19 7 PEDESTAL FAN
20 7.01 M&L for servicing of Wall Fan/Pedestal fan of any size by opening the blades, bearing, cleaning thoroughly internally & externally, providing fresh clean lubricants oil and greasing as required with and including re-assembling after replacement of defective components/ repair and replacing of minor items such as clamp, back cover, screw lock, nuts, welding guards etc testing for its smooth functioning complete all as specified and directed.\nNote: Spare parts will be measured and paid separately under respective item of Sch ‘A’.\n 5 Each Job
21 8 Supply only following items for pedestal fans:-
22 8.01 Gun metal bush as per existing size. 2 Each
23 8.02 Capacitor 4 Mfd, 230 Volts 2 Each
24 8.03 Fan blade assembly suitable for wall/pedestal fan 2 Each
25 9 M&L for rewinding Wall Fan/Pedestal Fan stator with super enameled copper wire of appropriate gauge including necessary insulation material complete varnishing and heating the new winding for proper insulation including cutting the existing winding wire from the stator and cleaning the slot complete all as directed for wall fan/padestal fan complete all as specified and directed. 2 Each Job
26 10 WATER COOLER
27 10.01 M&L for Servicing of water cooler of any make & type of capacity 40/80 by disconnecting electrically & mechanically,from various location for repair and maintenence including cleaning condenser coil and storage tank with chemical base solution and soda water and repalcement of unserviceable parts and refixing , re-connecting electrical and water connections, testing complete all as specified and directed. Note :- New components/parts shall be measured and paid separately under respective items 11 Each Job
28 11 Supply only following item for water cooler complete all as directed :-
29 11.01 Starting capacitor 40-60 MFD, Make:- Asian / Tesla or equiv 4 Each
30 11.02 Starting relay(as per sample), Make:- Renutral or equiv 4 Each
31 11.03 Running capacitor 10 MFD, Make:- Asian /Tesla or equiv 4 Each
32 11.04 Thermostate as per sample 4 Each
33 11.05 PVC float valve with PVC ball ,15mm dia (as per sample). 5 Each
34 11.06 PVC connection pipe 15 mm dia x 450 mm long 5 Each
35 11.07 PVC flexible waste water pipe 40 mm dia 5 Each
36 12 S&F in replacement sealed unit compressor unit single phase, 230 V and for water cooler, welding/brazing of gas pipe line, vaccume/ pressure leakage testing etc,Supply and charging of refrigerant gas of adequate quantity complete and testing incl taking down the old U/S sealed unit compessor all as specified and & directed for the 40/80 Ltrs capacity complete all as specified and directed. 1 Each
37 13 S&F of condensor coil complete with copper tube and aluminium fins for water cooler of cap upto 80 Ltrs with and including necessary refrigerant gas charging etc including testing complete all as specified and directed. 1 Each Job
38 14 S&F of sheet metal enclosures with 2 pins and earth plug single pole neutral link and one Nos MCB SP 32 amp complete including taking out existing and make connection with the new complete all as specified and directed. Make: Havells/Legrand/Indo-Asian 8 Each
39 15 S&F in replacement of FHP motor single phase suitable for 40/80 ltrs capacity as per existing complete all as specified and directed. 1 Each
40 16 REFRIGERATOR
41 16.01 M&L for servicing of refrigerator of any make and capacity from various location for maintenance including taking out old unserviceable parts and replacing with new parts and re-install the same at existing place after repairing, servicing and testing complete all as specified and directed. Note :-Spare parts shall be measured & paid separately for as supply only. 7 Each
42 17 Supply only following items for refrigerator complete all as directed:-
43 17.01 Thermostate (as per sample) Make :- Renutral / Ind foss 2 Each
44 17.02 Thermostate switch as per sample 2 Each
45 17.03 Relay as per existing. 2 Each
46 17.04 Magnetic door gasket complete suitable for 265 to 310 ltrs capacity as per sample. 1 Each
47 18 S&F in replacement new sealed unit compressor capacity of 265/300/310 ltr in replacement, welding the same with existing refrigerant pipe, leakage testing/vaccum test, supply & charging of refrigerant gas of adequate quantity testing complete incl taking down the old U/S sealed unit compressor from refrigerator andcomplete all as specified and directed. 1 Each
48 19 S&F in replacement of new condenser coil suitable for 265 to 310 ltrs capacity refrigerator including Welding/brazing of pipe lines, cahrging of refrigerant gas and testing complete all as specified and directed. 1 Each
49 20 M&L for charging with refrigerant gas suiatble for refrigerator, checking and testing the leakage from the system of any cap complete all as specified and directed. 1 Each Job
50 21 DEEP FREEZER
51 21.01 M&L for servicing of deep freezer of capacity 262 to 425 ltr from various location , cleaning the complete condenser coil & storage tank with chemical base solution and soda water complete restoring electrical connection and testing complete all as specified and directed. Note :- Parts to be replaced shall be measured and paid separately under respective items of schedule 'A'. 9 Each Job
52 22 Supply only following item for deep freezer complete all as directed :-
53 22.01 Starting capacitor 80/100 MFD Make : Tesla/EPCOS or equiv 2 Each
54 22.02 Running capacitor 30 MFD Make : Tesla/EPCOS or equiv 2 Each
55 22.03 Starting relay as per existing 2 Each
56 23 S&F in replacement of sealed unit compressor hermatically company sealed suitable for deep freezer of capacity 315 to 425 Ltr, single phase, 230 V and welding/ brazing of gas pipe line, vaccume pressure leakage testing etc including charging of adequate quantity of regrigerant gas , welding/brazing of copper pipe & testing complete all as directed.\nNote:- Old compressor unit will be the property of contractor as per schedule of credit. 1 Each Job
57 24 M&L for charging with refrigerant gas suiatble for deep freezer, checking and testing the leakage with the help of nitrogen gas and repairing the same by brazing etc compleate all as specified. 1 Each Job
58 25 DESERT COOLER
59 25.01 M&L for Servicing of desert coolers of any size/any height by taking down from the existing position,cleaning of bottom tank, side panel etc including repair/replacing unserviceable parts including painting one coat after preparation of surface with synthetic enamel paint of approved quality and colour on internal & external surface complete all as specified and directed. (Note:-Spares parts required shall be measured and paid separatley under respective item of schedule 'A' as supply only.) 45 Each Job
60 26 Supply only the following items suitable for desert cooler complete all as directed :-
61 26.01 Capacitor 4 MFD, Make –Asian /Epcos 20 Each
62 26.02 PVC Pipe transparent heavy duty ½ inch dia set for three side of desert cooler complete. 20 Set
63 26.03 Wood wool pad 15mm thick made out of chicken wire mesh fitted with fine quality wood wool , bind with GI wire for desert cooler as per site reqmt complete. 45 Set of three
64 26.04 Submersible water lifting pump for desert cooler 220/230 V single phase make - Bansal / summer cool or equiv 30 Each
65 26.05 Fan motor for18'' sweep with blade complete suitable for desert cooler Make:- Khaitan/CG/Orient 15 Each
66 26.06 Selector switch (rotory type) 3 speed ,230 V, 50 C/S suitable for desert cooler 20 Each
67 26.07 S&F Plug top 5 Amps, 230 Volts,50Hz complete 20 Each
68 27 WINDOW AC
69 27.01 M&L for Servicing of window type AC 1.5 TR /2.0 TR capacity from any location opening cleaning with Magna/Hibird solution , giving water air pressure, oiling including taking out old unserviceable parts and fixing new part like of suiatble cap capacitors (starting/running), relay as per site requirementr complete with re-fixing at existing place after repairing , servicing , testing complete all as specified and directed.\n 1 Each Job
70 28 Taking down carefully point wiring from existing place (light/fan, socket or power points complete) with all fittings such as switches, sockets ceiling rose , pendant holder, fitting and fixtures , MCB, Main switches, call bell etc and making good to disturbed surface to wall ,floor etc to match with existing surface either by using same colour distemper or white colour wash complete all as specified and directed. 95 Each point
71 29 M&L for point wiring PVC FRLS insulated and unsheathed copper stranded conductor cable of size 1.5 Sq mm , 1100 V drawn in and including PVC casing and capping complete including pressed Galvanised steel terminal box 1.6 mm thick of required size with Bakelite sheet 3mm thick for mounting switch , socket incl. brass screws and washer including PVC insulated and unsheathed stranded copper wire of size 1.5 Sq mm will be used as continuous earth wire for the following :-
72 29.01 One light /fan/bell point controlled by one, switch 50 Per point
73 29.02 One 5 pin 5/6 Amp socket on the same board 10 Per point
74 29.03 One 5 pin 5/6 Amp socket on independent board. 20 Per point
75 29.04 One 3 pin 15 Amp socket independent but with 2.5 q mm PVC insulated unsheathed copper stranded conductor and earth wire with 2.5 Sqmm 15 Per point
76 30 S & F switch piano type 240 V, 5 Amp , Sp one way flush type complete all as specified and directed. 80 Each
77 31 S&F socket 5 pins, 6 Amp, flush type piano (multi purpose) complete all as specified and directed. 30 Each
78 32 S&F Socket 15 Amps flush type 230 Volts , AC complete complete all as specified and directed. 15 Each
79 33 S&F switch 15 Amps flush type 230 Volts , AC complete complete all as specified and directed. 15 Each
80 34 M&L regulator Electronic type 240 Volt single phase suitable for ceiling fan step type complete all as specified and directed. 10 Each
81 35 S&F ceiling rose surface backelite, 65 x 20 mm three terminal complete all as specified and directed. 18 Each
82 36 S&F in repair of lamp holder pvc body with back plate complete all as specified and directed. 30 Each
83 37 S & F in repair single pole and neutral sheet duly powder coated distribution board for MCBs fitted with bus bar , Neutral link ,earth bar and din rail suitable for use on 240 V, 50 Hz supply double door SP&N DB system 8 ways complete all as specified and directed. 5 Each
84 38 S&F in repair MCB TPN 40 to 63 Amps, 10KA,415V incl all termnials, fitting etc. complete all as specified and directed. 15 Each
85 39 S&F in repair MCB SPN 32 Amps, 10KA, 250V incl all termnials, fitting etc. complete all as specified and directed. 15 Each
86 40 S&F in replacement MCB SP 6-32 Amp, 10 KA,240 Volt complete all as specified and directed. 30 Each
87 41 S&F in replacement energy efficient LED batten integrated type with LED tube 20 Watt, 4 ft long white complete with LED driver and LED batten with extruded aluminium/PC Body and PC diffuser including all accessories pre wire and connecting up with copper three core flexible wire complete all as directed. Make:- Bajaj cat ref BCLSB 20 WH/ Havells Cat part No LUMILINEPLUSBS20WLED865SPCSS/ Polycab Cat part No LDO0103023/ Crompton cat part No LCCLB-24-CDL 80 Each
88 42 S&F in repair LED bulb 9 watt complete all as specified and directed. 150 Each
89 43 S&F in repair tamper proof energy meter single phase 10-60 amp rating, 240V complete and old u/s elect meter to be depsited in E/M yard complete all as specified and directed. 15 Each
Disclaimer :