Military Engineer Services-MES has published Repair Maintenance Of Summer Appliances And Repair Maintenance Of Summer Appliances And Other Misc Work At Mil Stn Kalka Under Ge Jutogh. Submission Date for this Tender is 09-05-2020. Air Conditioner Tenders in KALKA Haryana. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 25-Mar-2020 | Extension of dates | Date | 16-04-2020 |
2 | 20-Apr-2020 | Extension of critical dates | Date | 09-05-2020 |
Name of Work: REPAIR MAINTENANCE OF SUMMER APPLIANCES AND OTHER MISC WORK AT MIL STN KALKA UNDER GE JUTOGH. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Qty | Units | |
1 | 1 | CEILING FAN | |||
2 | 1.01 | M&L for servicing of ceiling fans, any sweep/size at existing position from various locations for maintenance after removing cable connection from ceiling rose, checking, tightening of thread of down rod, opening of fan, greasing/oiling of bush/ bearing, re-assembling and fixing the same in position including replacement of minor part such as split pin, lock bolt, condensor clamp check nut and cable flexible from ceiling rose to ceiling fan and connection etc including testing for its smooth running complete all as specified and directed.\nNote: Spare parts will be paid separately under respective items | 225 | Each | |
3 | 2 | Supply only following component suitable for ceiling fan :- | |||
4 | 2.01 | Ball bearing as per sample suitable for ceiling fan Make: NBC/ SKF. | 70 | Each | |
5 | 2.02 | Capacitor of 2.5 Mfd Make: Unistar /EPCOS | 400 | Each | |
6 | 2.03 | Gun metal bush as per sample | 70 | Each | |
7 | 2.04 | Ceiling fan blade as per sample set of three suitable for 1200mm sweep. | 10 | Each | |
8 | 3 | M&L for rewinding of ceiling fan with appropriate gauge size super enameled copper wire including necessary insulation material after cleaning of stator for 1200/1400 mm sweep ceiling fans complete all as specified and directed. | 70 | Each Job | |
9 | 4 | Exhaust Fan | |||
10 | 4.01 | M&L for servicing of exhaust fans, any sweep/size at existing position from various location for maintenance after removing cable connection from ceiling rose, checking, tightening of nuts, bolts, opening of fan, greasing/oiling of bearing, re-assembling and fixing the same in position including replacement of minor part such as split pin and cable flexible from ceiling rose to exhaust fan and connection etc including testing for its smooth running complete all as specified and directed.\nNote: Spare parts will be paid separately under respective items | 50 | Each Job | |
11 | 5 | Supply only following items for exhaust fan:- | |||
12 | 5.01 | Capacitor 4 Mfd, 230 Volt Make: Unistar/EPCOS. | 50 | Each | |
13 | 5.02 | Ball bearing as per sample suitable for exhaust fan Make: NBC/SKF | 50 | Each | |
14 | 5.03 | Exhaust fan blade of any sweep with screws/bolts, nuts. | 10 | Each | |
15 | 5.04 | Exhaust fan louvers complete with nut & bolts etc. | 30 | Each | |
16 | 6 | M&L for rewinding exhaust fan stator with super enameled copper wire of appropriate gauge including necessary insulation material complete varnishing and heating the new winding for proper insulation including cutting the existing winding wire from the stator and cleaning the slot complete all as directed for following sizes:- | |||
17 | 6.01 | 300mm sweep | 70 | Each Job | |
18 | 6.02 | 450 mm sweep | 30 | Each Job | |
19 | 7 | PEDESTAL FAN | |||
20 | 7.01 | M&L for servicing of Wall Fan/Pedestal fan of any size by opening the blades, bearing, cleaning thoroughly internally & externally, providing fresh clean lubricants oil and greasing as required with and including re-assembling after replacement of defective components/ repair and replacing of minor items such as clamp, back cover, screw lock, nuts, welding guards etc testing for its smooth functioning complete all as specified and directed.\nNote: Spare parts will be measured and paid separately under respective item of Sch ‘A’.\n | 5 | Each Job | |
21 | 8 | Supply only following items for pedestal fans:- | |||
22 | 8.01 | Gun metal bush as per existing size. | 2 | Each | |
23 | 8.02 | Capacitor 4 Mfd, 230 Volts | 2 | Each | |
24 | 8.03 | Fan blade assembly suitable for wall/pedestal fan | 2 | Each | |
25 | 9 | M&L for rewinding Wall Fan/Pedestal Fan stator with super enameled copper wire of appropriate gauge including necessary insulation material complete varnishing and heating the new winding for proper insulation including cutting the existing winding wire from the stator and cleaning the slot complete all as directed for wall fan/padestal fan complete all as specified and directed. | 2 | Each Job | |
26 | 10 | WATER COOLER | |||
27 | 10.01 | M&L for Servicing of water cooler of any make & type of capacity 40/80 by disconnecting electrically & mechanically,from various location for repair and maintenence including cleaning condenser coil and storage tank with chemical base solution and soda water and repalcement of unserviceable parts and refixing , re-connecting electrical and water connections, testing complete all as specified and directed. Note :- New components/parts shall be measured and paid separately under respective items | 11 | Each Job | |
28 | 11 | Supply only following item for water cooler complete all as directed :- | |||
29 | 11.01 | Starting capacitor 40-60 MFD, Make:- Asian / Tesla or equiv | 4 | Each | |
30 | 11.02 | Starting relay(as per sample), Make:- Renutral or equiv | 4 | Each | |
31 | 11.03 | Running capacitor 10 MFD, Make:- Asian /Tesla or equiv | 4 | Each | |
32 | 11.04 | Thermostate as per sample | 4 | Each | |
33 | 11.05 | PVC float valve with PVC ball ,15mm dia (as per sample). | 5 | Each | |
34 | 11.06 | PVC connection pipe 15 mm dia x 450 mm long | 5 | Each | |
35 | 11.07 | PVC flexible waste water pipe 40 mm dia | 5 | Each | |
36 | 12 | S&F in replacement sealed unit compressor unit single phase, 230 V and for water cooler, welding/brazing of gas pipe line, vaccume/ pressure leakage testing etc,Supply and charging of refrigerant gas of adequate quantity complete and testing incl taking down the old U/S sealed unit compessor all as specified and & directed for the 40/80 Ltrs capacity complete all as specified and directed. | 1 | Each | |
37 | 13 | S&F of condensor coil complete with copper tube and aluminium fins for water cooler of cap upto 80 Ltrs with and including necessary refrigerant gas charging etc including testing complete all as specified and directed. | 1 | Each Job | |
38 | 14 | S&F of sheet metal enclosures with 2 pins and earth plug single pole neutral link and one Nos MCB SP 32 amp complete including taking out existing and make connection with the new complete all as specified and directed. Make: Havells/Legrand/Indo-Asian | 8 | Each | |
39 | 15 | S&F in replacement of FHP motor single phase suitable for 40/80 ltrs capacity as per existing complete all as specified and directed. | 1 | Each | |
40 | 16 | REFRIGERATOR | |||
41 | 16.01 | M&L for servicing of refrigerator of any make and capacity from various location for maintenance including taking out old unserviceable parts and replacing with new parts and re-install the same at existing place after repairing, servicing and testing complete all as specified and directed. Note :-Spare parts shall be measured & paid separately for as supply only. | 7 | Each | |
42 | 17 | Supply only following items for refrigerator complete all as directed:- | |||
43 | 17.01 | Thermostate (as per sample) Make :- Renutral / Ind foss | 2 | Each | |
44 | 17.02 | Thermostate switch as per sample | 2 | Each | |
45 | 17.03 | Relay as per existing. | 2 | Each | |
46 | 17.04 | Magnetic door gasket complete suitable for 265 to 310 ltrs capacity as per sample. | 1 | Each | |
47 | 18 | S&F in replacement new sealed unit compressor capacity of 265/300/310 ltr in replacement, welding the same with existing refrigerant pipe, leakage testing/vaccum test, supply & charging of refrigerant gas of adequate quantity testing complete incl taking down the old U/S sealed unit compressor from refrigerator andcomplete all as specified and directed. | 1 | Each | |
48 | 19 | S&F in replacement of new condenser coil suitable for 265 to 310 ltrs capacity refrigerator including Welding/brazing of pipe lines, cahrging of refrigerant gas and testing complete all as specified and directed. | 1 | Each | |
49 | 20 | M&L for charging with refrigerant gas suiatble for refrigerator, checking and testing the leakage from the system of any cap complete all as specified and directed. | 1 | Each Job | |
50 | 21 | DEEP FREEZER | |||
51 | 21.01 | M&L for servicing of deep freezer of capacity 262 to 425 ltr from various location , cleaning the complete condenser coil & storage tank with chemical base solution and soda water complete restoring electrical connection and testing complete all as specified and directed. Note :- Parts to be replaced shall be measured and paid separately under respective items of schedule 'A'. | 9 | Each Job | |
52 | 22 | Supply only following item for deep freezer complete all as directed :- | |||
53 | 22.01 | Starting capacitor 80/100 MFD Make : Tesla/EPCOS or equiv | 2 | Each | |
54 | 22.02 | Running capacitor 30 MFD Make : Tesla/EPCOS or equiv | 2 | Each | |
55 | 22.03 | Starting relay as per existing | 2 | Each | |
56 | 23 | S&F in replacement of sealed unit compressor hermatically company sealed suitable for deep freezer of capacity 315 to 425 Ltr, single phase, 230 V and welding/ brazing of gas pipe line, vaccume pressure leakage testing etc including charging of adequate quantity of regrigerant gas , welding/brazing of copper pipe & testing complete all as directed.\nNote:- Old compressor unit will be the property of contractor as per schedule of credit. | 1 | Each Job | |
57 | 24 | M&L for charging with refrigerant gas suiatble for deep freezer, checking and testing the leakage with the help of nitrogen gas and repairing the same by brazing etc compleate all as specified. | 1 | Each Job | |
58 | 25 | DESERT COOLER | |||
59 | 25.01 | M&L for Servicing of desert coolers of any size/any height by taking down from the existing position,cleaning of bottom tank, side panel etc including repair/replacing unserviceable parts including painting one coat after preparation of surface with synthetic enamel paint of approved quality and colour on internal & external surface complete all as specified and directed. (Note:-Spares parts required shall be measured and paid separatley under respective item of schedule 'A' as supply only.) | 45 | Each Job | |
60 | 26 | Supply only the following items suitable for desert cooler complete all as directed :- | |||
61 | 26.01 | Capacitor 4 MFD, Make –Asian /Epcos | 20 | Each | |
62 | 26.02 | PVC Pipe transparent heavy duty ½ inch dia set for three side of desert cooler complete. | 20 | Set | |
63 | 26.03 | Wood wool pad 15mm thick made out of chicken wire mesh fitted with fine quality wood wool , bind with GI wire for desert cooler as per site reqmt complete. | 45 | Set of three | |
64 | 26.04 | Submersible water lifting pump for desert cooler 220/230 V single phase make - Bansal / summer cool or equiv | 30 | Each | |
65 | 26.05 | Fan motor for18'' sweep with blade complete suitable for desert cooler Make:- Khaitan/CG/Orient | 15 | Each | |
66 | 26.06 | Selector switch (rotory type) 3 speed ,230 V, 50 C/S suitable for desert cooler | 20 | Each | |
67 | 26.07 | S&F Plug top 5 Amps, 230 Volts,50Hz complete | 20 | Each | |
68 | 27 | WINDOW AC | |||
69 | 27.01 | M&L for Servicing of window type AC 1.5 TR /2.0 TR capacity from any location opening cleaning with Magna/Hibird solution , giving water air pressure, oiling including taking out old unserviceable parts and fixing new part like of suiatble cap capacitors (starting/running), relay as per site requirementr complete with re-fixing at existing place after repairing , servicing , testing complete all as specified and directed.\n | 1 | Each Job | |
70 | 28 | Taking down carefully point wiring from existing place (light/fan, socket or power points complete) with all fittings such as switches, sockets ceiling rose , pendant holder, fitting and fixtures , MCB, Main switches, call bell etc and making good to disturbed surface to wall ,floor etc to match with existing surface either by using same colour distemper or white colour wash complete all as specified and directed. | 95 | Each point | |
71 | 29 | M&L for point wiring PVC FRLS insulated and unsheathed copper stranded conductor cable of size 1.5 Sq mm , 1100 V drawn in and including PVC casing and capping complete including pressed Galvanised steel terminal box 1.6 mm thick of required size with Bakelite sheet 3mm thick for mounting switch , socket incl. brass screws and washer including PVC insulated and unsheathed stranded copper wire of size 1.5 Sq mm will be used as continuous earth wire for the following :- | |||
72 | 29.01 | One light /fan/bell point controlled by one, switch | 50 | Per point | |
73 | 29.02 | One 5 pin 5/6 Amp socket on the same board | 10 | Per point | |
74 | 29.03 | One 5 pin 5/6 Amp socket on independent board. | 20 | Per point | |
75 | 29.04 | One 3 pin 15 Amp socket independent but with 2.5 q mm PVC insulated unsheathed copper stranded conductor and earth wire with 2.5 Sqmm | 15 | Per point | |
76 | 30 | S & F switch piano type 240 V, 5 Amp , Sp one way flush type complete all as specified and directed. | 80 | Each | |
77 | 31 | S&F socket 5 pins, 6 Amp, flush type piano (multi purpose) complete all as specified and directed. | 30 | Each | |
78 | 32 | S&F Socket 15 Amps flush type 230 Volts , AC complete complete all as specified and directed. | 15 | Each | |
79 | 33 | S&F switch 15 Amps flush type 230 Volts , AC complete complete all as specified and directed. | 15 | Each | |
80 | 34 | M&L regulator Electronic type 240 Volt single phase suitable for ceiling fan step type complete all as specified and directed. | 10 | Each | |
81 | 35 | S&F ceiling rose surface backelite, 65 x 20 mm three terminal complete all as specified and directed. | 18 | Each | |
82 | 36 | S&F in repair of lamp holder pvc body with back plate complete all as specified and directed. | 30 | Each | |
83 | 37 | S & F in repair single pole and neutral sheet duly powder coated distribution board for MCBs fitted with bus bar , Neutral link ,earth bar and din rail suitable for use on 240 V, 50 Hz supply double door SP&N DB system 8 ways complete all as specified and directed. | 5 | Each | |
84 | 38 | S&F in repair MCB TPN 40 to 63 Amps, 10KA,415V incl all termnials, fitting etc. complete all as specified and directed. | 15 | Each | |
85 | 39 | S&F in repair MCB SPN 32 Amps, 10KA, 250V incl all termnials, fitting etc. complete all as specified and directed. | 15 | Each | |
86 | 40 | S&F in replacement MCB SP 6-32 Amp, 10 KA,240 Volt complete all as specified and directed. | 30 | Each | |
87 | 41 | S&F in replacement energy efficient LED batten integrated type with LED tube 20 Watt, 4 ft long white complete with LED driver and LED batten with extruded aluminium/PC Body and PC diffuser including all accessories pre wire and connecting up with copper three core flexible wire complete all as directed. Make:- Bajaj cat ref BCLSB 20 WH/ Havells Cat part No LUMILINEPLUSBS20WLED865SPCSS/ Polycab Cat part No LDO0103023/ Crompton cat part No LCCLB-24-CDL | 80 | Each | |
88 | 42 | S&F in repair LED bulb 9 watt complete all as specified and directed. | 150 | Each | |
89 | 43 | S&F in repair tamper proof energy meter single phase 10-60 amp rating, 240V complete and old u/s elect meter to be depsited in E/M yard complete all as specified and directed. | 15 | Each |